VALVE CONTROLLERS Controllers for Dust Extr 2010 / 2011 action Technology

Similar documents
Sensors and Systems for Combustion Engineering

Electronic Limit Switch Type

HE Operating Manual (Original Language German) Solenoid Valve Control. # Version 2.13

AS-I

DSL-240 MkIII Single Pass Dust Monitor Measures mg/m 3 using DDP

SINAMICS GM150 IGCT version

Valve Manifolds Type 44 VTSA, Type 45 VTSA-F Inch Series Overview

JUMO dtrans p20. Process pressure transmitter. Type Brief description. Key features. Block diagram

Positioners Converters Limit Switches Position Transmitters Solenoid Valves Accessories. Selection and Application

Flow VA 550 / 570. DVGW tested. Flow.

Differential pressure sensor

Motor Starter Reverse MSR22-FBP

Valve Manifolds Type 44 VTSA, Type 45 VTSA-F Metric Series Overview

Current Automation Catalogue

AQUAVAR Intelligent Pump Controller TECHNICAL BROCHURE BCPAQIPC R2

Hand-Held Pressure Measuring Instrument "Manoport"

7 Services Control and monitoring

DM01. Battery Powered Precision Digital Gauge. Stainless Steel Sensor. class 0.05

RVP-R- VAV controller. In explosion-proof version

The motor starter on the power bus. Solutions for conveyor technology. Full speed ahead

pag. 5 pag. 8 Who we are: evolution sectors pag. 11 pag. 14 Designation pag. 27 Versions pag. 18 pag. 31 Accessories and Options pag.

ECONOMISER SERIES E2T USER MANUAL

VP23 3-way proportional pressure control valve Directly-controlled seat valve with µp-driven pressure control G 1/4... G 3/4

Controller Specification Sheet

Solenoid Valve Island Type 3965

Flash Point Process Analyzer

AS-I

Type Electronic Limit Switch

DL 01. Battery Powered Precision Digital Gauge for Leak Testing. Stainless Steel Sensor. class 0.05

Product Information Stepper Motor-driven Diaphragm Dosing Pump MEMDOS SMART LP

Positive displacement batch controller

JUMO dtrans p20 DELTA

Level and Flow Measurement. Sludge Finder 2

MICROMAT-F / MINIMAT-F SCREWDRIVING SYSTEM

DSL-220 MkIII Single Pass Opacity Monitor Measures 0-100% Opacity

CORNERING LIGHTING MODULE CLM02-CAN INSTALLATION MANUAL

Electronic Pressure Switch EDS 3000

VP23, 3-way proportional pressure control valves Seat valve with μp-driven pressure control

ExBin-P Pressure switches 5 Pa Pa

Table of Contents. Table of Contents UniTrain UniTrain courses UniTrain mechatronic courses IMS 23/24 with 3/4 subsystems

ARCAPRO positioner. Positioner customized for specific tasks

Differential pressure transmitter PASCAL Ci4 Delta P

JUMO MIDAS Pressure transmitter

Special voltages: Voltage >500 V AC are only permissible with external control box. 3-phase AC Voltages/frequencies. 1-phase AC Voltages/frequencies

Differential Pressure Sensors

JUMO dtrans p35. Pressure Sensor with IO-Link. Application. Brief description. Customer benefits. Special features

Data Sheet SCHISCHEK EXCOS-P. Pressure sensor 20 Pa Pa. Supplied by. .com. Call us on +44 (0)

Operating Instructions (Translation)

Starts, stops and protects. Emotron TSA Softstarter

Local Control Network - building controls in perfection

mass flowmeter for compressed air

Differential Pressure and Flow meters Accessories for the Media Series

Pressure sensor for liquid and gaseous media QBE620-P...

Paddle-wheel flow controller for On/Off control

ecotrans Lf 01/02 Microprocessor Transmitter / Switching Device for Conductivity

ABB i-bus KNX DG/S x DALI-Gateway Basic

GS2 Series - Introduction

Series 3730 Electropneumatic Positioner Type

Turbidity and Suspended Solids Transmitter

High-response valve with integrated digital axis controller (IAC-Multi-Ethernet)

Flow VA 500/ 520. Flow sensors for compressed air and gases incl. temperature measurement. Verbrauch.

Special valves. Series. Solenoids. IP65 (with connector) Zones 1, 21 II 2 G II 2 GD EEx me IP64. Aluminium. Operation. Page no. EEx me IP65.

XMP ci. Process Pressure Transmitter with HART -communication. Ceramic Sensor. accuracy according to IEC 60770: 0.1 % FSO.

Differential pressure gauge Model , copper alloy Model , stainless steel version

SUCO Product Overview

REVISION HISTORY REVISION HISTORY

Inline Flow meter for compressed air and gases DN15 (1/2 ) - DN80 (3 )

Online data sheet FLOWSIC100 VOLUME FLOW MEASURING DEVICES

Differential pressure transmitter PASCAL Ci4 Delta P

Pressure transmitter JUMO dtrans p02

Total Control Board. Installation, Operation and Maintenance Manual. Publication 2949A (GB) (From October 2007)

R-Series Rod Model RS. Data Sheet. Model RS Rod-style sensor with IP68/IP69K Super Shield Housing. Interrogation Return wire.

fluid technology temperature sensors 1600 intelligent temperature sensor membrane keyboard, USB opto interface

SUCO Product Overview

VP23. 3-way proportional pressure control valve Directly-controlled seat valve with μp-driven pressure control G 1/4 to G 3/4 Nominal diameter 8/16

Automation is the techniques and equipment used to achieve automatic operation or control.

Paddle-wheel flow controller with optical principle for On/Off control

Hydraulic Valves «DSV»

For reliable control of small, large or multi-system-type lubrication systems

ALIANT ULTRALIGHT BATTERY is a product by ELSA Solutions S.r.l

T 3965 EN Type 3965 Solenoid Valve Island To control pneumatic actuators

Vortex Flow Sensors VA Di also suitable for applications in condensation and particle laden gases. Drawing 1

Portable pressure calibrator, Wally Box III Model CPH7600

GEMÜ 539 esydrive Motorized globe valve

THYRO-PX SERIES DIGITAL THYRISTOR SCR POWER CONTROLLER UP TO 2900 AMPS

TOUCH PLS TOUCHSCREEN PLS A NEW HORIZON IN PROGRAMMABLE LIMIT SWITCHES

Ultrasonic filling level sensor UFM 200 / 600 C2 / C4 / R / MD

SITRANS P measuring instruments for pressure

JUMO ecotrans Lf 01/02

EPS/ELA-Series User Manual EPS/ELA 250W

Heating Cost Allocation Valve with local acquisition of the flow temperature

Proportional directional valves type DPZO-A* two stage without position transducer, ISO 4401 sizes 10, 16 and 25

Simply a question of better measurement

Flexible. Intelligent. Trendsetting.

QUANTUM LX CONTROL PANEL

Flow - magnetic inductive - probe form

THYRISTORS T2-2PH from 45A to 2700A Specifications Universal 2 Phase Thyristor Unit , March 2012

Pressure Transmitter

JUMO thermocor. Portable measuring system for AMS2750 and CQI-9. Brief description. Block diagram. Special features. JUMO thermocor.

Unidrive M600 High performance drive for induction and sensorless permanent magnet motors

Transcription:

VALVE CONTROLLERS Controllers for Dust Extraction 2010 Technology / 2011

Valve controllers for all cases HESCH has the skills and technology to tackle any control task for dedusting of filter and dust extraction systems with fibrous filter technology. From microcontrollers to plant control systems for large industrial filters we not only provide custom made solenoid valve controllers but, on request, also the complete control system for the dedusting process. Consequently user-friendly With field bus supported solenoid valve control systems, HESCH offers dedusting control systems which can be individually assembled to form a custom made system due to their modular design. Depending on the size of the dedusting plant there are very different requirements on process control. HESCH offers a wide range of solenoid valve controllers from the reasonably priced and variable microcontroller-operated HE 5711 to the comfortable dedusting control system HE 5750 for large industrial filtration plants. Efficient and environmentally friendly... The intelligence of the filter controllers has a considerable influence on the reduction of the emission values and the energy costs. We offer the complete automation spectrum, both for new installations as well as for increasing the performance of existing fibrous filter systems. All valve controllers from HESCH feature single valve tests, cyclic cleaning and post-cleaning and their casing versions may be installed in Zone 22. 2

Expandable... For some solenoid valve controllers from HESCH the number of controlled valves may be increased from 8 up to 1024 by means of expansion modules. System integration... The valve controllers communicate with the process control over digital inputs and outputs or via Profibus DP, Modbus or Ethernet TCP/ IP (HE 5750). 3

Application The pressure transmitter HE 1149 is used to record the system pressure and to monitor the function of solenoid valves by measurements in the pressure tanks. Depending on the measured pressure, it supplies a 4 20 ma signal. Our controllers may also be used for fluidizers. Due to the flexible adjustment of the pulse and oause times over a wide range you can benefit from the advantages of a ready-made control component also for this application. 4 Technical modifications reserved.

The differential pressure measuring transducers from HESCH are universal measuring transducers for small and medium pressures. Measuring ranges between 2.5 and 1000 mbar can be realised. Two connection cables are used for the power supply. The feed current is the measurement signal from 4...20 ma. The operating state is indicated with an LED. The valve controller HE 5750 is a Master-Slave system for large installations. According to the size of the plant the associated slaves required are connected to the master controller per field bus. Each slave controller is assigned to one filter chamber, locally and technically. This flexible concept adapts itself to practically any required number of filter chambers and valves. Technical modifications reserved. 5

HE 5711 µp Solenoid Valve Controller Microcontroller-operated valve controller The microcontroller-operated valve controller HE 5711 is used for the cycle control of electromagnetic valves in industrial dust filter systems. The flexible design concept enables the use as PCB version with spacer sleeves, as standard rail version or as separate control unit in plastic casing with ATEX 22 approval. TECHNICAL DATA Current consumption 230/115 V AC, 50...60 Hz or 24 V DC 30 VA HE 5711 PCB Version 230 V AC 571105 1 HE 5711 Standard Rail Support 230 V AC 571135 1 Operating temperature 0 C +60 C HE 5711 Casing Version 230 V AC 571165 1 Valve outputs 8 Valve voltage / current 24 V DC / max. 1 A Indications: LED 1 x green "Operation" 1 x yellow "Cleaning" 8 x red, assigned to the valves Control elements: Start button Test button Set cycles are executed The next valve is cleaned Connection Set with 1 Cable Gland M25, 2 Cable Glands M32 incl. Multiple Sealing Inserts and Sealing Bolts 572920 1 Rotary selector switch Number of valves from 1...8 Cycle setting Potentiometer Pulse setting Pause setting Electrical connection Cage clamp terminal strips Valve current 1 A at a pulse time 1 s and a pause the pulse time, output short-circuit proof Versions PCB with collar sleeves for assembly with M4 screws Installation on standard rail support Dust-proof plastic casing with transparent cover ATEX CE ATEX II 3D T60 C IP65, Zone 22 6 Technical modifications reserved.

HE 5712 µp Solenoid Valve Controller Valve controller for industrial filters The solenoid valve controller HE 5712 is used for the time- or differentialpressure-dependent control of solenoid valves in industrial dust extraction technology. Up to 8 valves are controlled. The valves are activated sequentially and monitored for overflow and interruption. Errors are displayed on the controller. The controller is simple to operate through symbol labelling and the use of LEDs for status indication and as an adjustment aid without complicated menu structures. The differential pressure is directly measured by the controller; an external sensor is not required. The separately available connection set with appropriate cable glands as well as pre-assembled cables with valve connectors available in different lengths complement the controller. TECHNICAL DATA 115 V AC / 230 V AC / 24 V DC HE 5712, 8 Valves, 230 V AC 57121000 1 Operating temperature -20 C +50 C Valve outputs Max. 8 Valve voltage / current 24 V DC / max. 1 A Indications: 7-segment display Control elements Electrical connection 3-digit, 14 mm height, red 5 function keys Spring clamp terminals Settings Pulse and pause time, number of valves, post-cleaning cycles as well as complete or partial cycle, P-measuring range, high and low alarm, upper and lower cleaning threshold, post-cleaning threshold Cable Glands 2 x M32 and 3 x M16 incl. Multiple Sealing Insert and Sealing Plug 57120099 1 Service Adapter USB/TTL (USB Device/RJ45) 58513011 1 Analogue output 4...20 ma Valve Cable 2.50 m incl. Connector and Wire-end Ferrules 57310097 1 Digital inputs Start, post-cleaning, enable 24 V DC technology to connect potentialfree contacts Valve Cable 5.00 m incl. Connector and Wire-end Ferrules 57310098 1 Relay output 1 x operation-/and fault message, contact load 250 V AC / 5 A Interfaces Dimensions Measuring range RJ10 for PC configuration 200 x 150 x 80 mm (without support 75 mm) (W x H x D), level of protection: IP65 Max. 40 mbar (100 resp. 500 mbar can be supplied on request) ATEX CE ATEX II 3D T60 C IP65, Zone 22 Dedusting Time-controlled without P-evaluation or automatically via integrated ΔP-measurement Post-cleaning Triggered via momentary contacts or settable differential pressure thresholds Technical modifications reserved. 7

HE 5721 µp Solenoid Valve Controller Valve controller for industrial filters The solenoid valve controller HE 5721 is used to pulse solenoid valves in industrial dust extraction technology. The controller realises numerous control and monitoring functions and optionally can be equipped with ΔPmeasurement and control. The cleaning takes place time-controlled or ΔP-dependent (with optional ΔP-controller) with switching thresholds or pause control. The valves are monitored for excess current (short-circuit) and interruption. Optionally, mechanical valve function monitoring can be carried out with a pressure switch. The device is suitable for use in Explosion Zone 22. TECHNICAL DATA Current consumption 230/115 V AC, 50 60 Hz or 24 V DC 30 VA Operating temperature 0 C +50 C Valve outputs Valve voltage / current 12 (24 with expansion) 24 V DC / max. 1 A Indications: LED Control elements: Potentiometer Test button Electrical connection 1 x green "Operation", 1 x yellow "Cleaning", 1 x red "Fault", 12 x red, assigned to the valves Number of valves from 1 to 12 Cycle setting Pulse setting Pause setting Post-cleaning cycles The next valve is cleaned Screw terminal strips: 2.5 mm² mains supply 1.5 mm² valve connections Connection Set for up to 12 Valves 57 29 20 1 Main Cabling for 12 Valves, 1 m length 57 29 90 1 Main Cable for 12 Valves, linear metre 57 29 95 1 Valve current 1 A at a pulse time 1 s and a pause the pulse time, output short-circuit proof Versions Plastic casing Relay output: 12 (24) valves without ΔP 12 (24) valves with ΔP ATEX CE ATEX II 3D T60 C IP65, Zone 22 1 change-over contact operation-/and fault message Contact load 250 V AC, 5 A 1 make contact for cleaning message Contact load 250 V AC, 5 A Measuring ranges ΔP-controller 25/50/100/250/500 mbar 8 Technical modifications reserved.

HE 5721 FP µp Solenoid Valve Controller Valve controller for industrial filters The solenoid valve controller HE 5721 FP is used to pulse solenoid valves in industrial dust extraction technology. The controller realises numerous control and monitoring functions and is equipped with ΔP-measurement and control. The cleaning takes place time-controlled or ΔP-dependent with thresholds or pause control. The valves are monitored for excess current (short-circuit) and interruption. Optionally, pneumatic valve function monitoring can be carried out with a pressure switch. The device is suitable for use in Explosion Zone 22. TECHNICAL DATA Current consumption 230/115 V AC, 50...60 Hz or 24 V DC 30 VA Operating temperature 0 C +50 C Valve outputs Valve voltage / current 12 (24 with expansion) 24 V DC / max. 1 A Indications: LED Control elements: Potentiometer Test button Electrical connection Valve current 1 x green "Operation", 1 x yellow "Cleaning", 1 x red "Fault", 24 x red, assigned to the valves Cleaning start Cleaning stop Alarm threshold Post-cleaning start Post-cleaning cycles Number of valves 1-24 Pause time Pulse time The next valve is cleaned Screw terminal strips: 2.5 mm² mains supply 1.5 mm² valve connections 1 A at a pulse time 1 s and a pause the pulse time, output short-circuit proof Connection Set for up to 12 Valves 57 29 20 1 Main Cabling for 12 Valves, 1 m length 57 29 90 1 Main Cable for 12 Valves, linear metre 57 29 95 1 Versions Plastic casing Relay output: 12 (24) valves without ΔP 12 (24) valves with ΔP ATEX CE ATEX II 3D T60 C IP65, Zone 22 1 change-over contact operation-/and fault message Contact load 250 V AC, 5 A 1 make contact for cleaning message Contact load 250 V AC, 5 A Measuring ranges ΔP-controller 25/50/100/250/500 mbar Technical modifications reserved. 9

HE 5722 µp Solenoid Valve Controller Valve controller for industrial filters incl. P-measurement The solenoid valve controller HE 5722 is used for the time-controlled or differential-pressure-dependent activation of solenoid valves in industrial dust extraction technology. Through the use of a microprocessor a flexible choice of functions is possible, numerous monitoring functions are realised. Besides the cleaning thresholds, two alarm thresholds can be defined. The switching events can be freely assigned to the three relays in the menu. TECHNICAL DATA Current consumption 230/115 V AC, 50...60 Hz or 24 V DC 30 VA HE 5722, 24 Valves, 0...25 mbar, 230 V AC 57221000 1 HE 5722, 24 Valves, 0...25 mbar, 115 V AC 57221100 1 Operating temperature 0 C 50 C HE 5722, 24 Valves, 0...25 mbar, 24 V DC 57221200 1 Valve outputs 24 Valve voltage / current 24 V DC / max. 1 A Indications: 7-segment display Control elements Electrical connection Valve current Versions Plastic casing Analogue input 2- and 4-digit, 14 mm height, red 4 function keys Spring clamp terminals 1 A Level of protection IP65 4 20 ma incl. sensor supply Digital input Start, post-cleaning and fault acknowledgement Relay output: 3 change-over contacts Contact load 250 V AC, 5 A, freely configurable Analogue output Interfaces: USB device 4 20 ma Type B ATEX CE ATEX II 3D T60 C IP65, Zone 22 Measuring ranges 0 25/50/70/100/500 mbar 10 Technical modifications reserved.

HE 5731 µp Solenoid Valve Controller Valve controller for industrial filters The solenoid valve controller HE 5731 is used for the time- or differentialpressure-dependent control of solenoid valves in industrial dust extraction technology. Up to 64 valves are controlled with the base unit and three expansion units. The base unit communicates with the expansions over a RS-485 connection. The valves are activated sequentially and are not chamber-oriented. They are monitored for excess current and interruption. Errors are displayed on the base unit. The controller is simple to operate through symbol labelling and LEDs for status and differential pressure indications. The differential pressure signal is supplied as 4...20 ma value; as a result the hose connection is less susceptible to faults. The controller is available purely as time controller in a version without differential pressure display. Accessories, such as the differential pressure sensor HE 5409, the P-connection set and the valve connector with various line lengths complement the controller. TECHNICAL DATA 230/115 V AC, 50...60 Hz or 24 V DC Current consumption 30 VA Operating temperature -20 C 50 C Valve outputs 16 (with expansions max. 64) Valve voltage / current 24 V DC / max. 1 A Indications: HE 5731, 16 Valves, 24 V DC, with Analogue Input HE 5731, 16 Valves, 115 V AC, with Analogue Input HE 5731, 16 Valves, 230 V AC, with Analogue Input 57310000 1 57311100 1 57311000 1 HE 5731 Expansion Unit 16 Valves 57310001 1 7-segment display Control elements Electrical connection 3-digit, 14 mm height, red 4 function keys Spring clamp terminals Valve current 1 A Cable Glands 3 x M32 and 2 x M16 incl. Multiple Sealing Insert 57310099 1 Versions Plastic casing 0 valves, control unit only without analogue input 16 valves without analogue input 0 valves, control unit only with analogue input 16 valves with analogue input Expansion unit 16 valves Connection Cable for Expansion Unit on request 1 Analogue input 4 20 ma incl. sensor supply Digital input Relay output: Start, post-cleaning and fault acknowledgement 1 change-over contact Contact load 250 V AC, 5 A Interfaces: ATEX CE ATEX II 3D T60 C IP65, Zone 22 RJ10 For PC configuration Technical modifications reserved. 11

HE 5760 Field Bus Supported Dedusting System Dedusting system for industrial filtration plants The system HE 5760 consists of the master controller HE 5760 and the respective valve-i/o-units HE 5725. The dedusting process is chamberoriented. A maximum of 6 chambers with 24 dedusting valves each may be controlled and monitored. The number of chambers and valves can be adapted by simple configuration of parameters. The dedusting processes (dependent on differential pressure or time or pause control dependent on differential pressure) are already installed and can be easily called up in the configuration menus. For simple parameter setting and commissioning the PC software 'Smart-Tool' is available on request. The control components are supplied pre-installed in a control box. The valve connections with moulded valve connectors are included on request. TECHNICAL DATA HE 5760 TECHNICAL DATA SYSTEM Indications: Graphic LC display 24 V DC Resolution: 128 x 64 pixels Display area: 66 x 33 mm Colour: yellow-green Adjustable brightness and contrast Maximum system size of which on the expansion Valve function monitoring 6 chambers each with 24 valves Option: 12 chambers each with 24 valves 12 x valve controller HE 5725 each with 12 outputs Option: 24 x valve controller HE 5725 each with 12 outputs Electric and pneumatic Hose rupture detection Not available Control elements: Inputs: Foil keypad Real-time clock Interfaces 8 function keys, cursor block Optional Master 2 x analogue 4...20 ma: differential and system pressure. 5 x digital: local remote switchover / fault acknowledgement / start / stop / post-cleaning, CAN interface Galvanically isolated, 50 kbit/s Slave: 2 x analogue 4...20 ma: tank pressure USB device Type B for updates and PC communication Outputs: Casing Dimensions Ambient temperature Control panel built-in casing 196 x 126 x 45 mm Operation: -10 C 55 C Storage: -25 C 60 C Transport: -25 C 85 C Master 4 x digital: operation, cleaning, fault, pulse 96...230 V AC value voltage input Ambient temperature Operation: -10 C 50 C Option Operation: -40 C 60 C Electrical connections Screw plug terminals Process control communication Contacts on request Specification of the filter necessary on request CE, UL 12 Technical modifications reserved.

HE 5750 Field Bus Supported Dedusting System Dedusting system for industrial filtration plants The HE 5750 for large installations is a Master-Slave system. According to the size of the plant the associated slaves required are connected to the master controller per field bus. In each case one slave controller is assigned to one filter chamber, locally and technically. This flexible concept adapts itself to practically any required number of filter chambers and valves. The system can be configured customer-specific and preassembled up to the valve connector. That reduces the commissioning times and costs considerably. The support is simplified through remote diagnostics and maintenance by means of modem- or internet connection (Remote-Access). TECHNICAL DATA HE 5750 TECHNICAL DATA SYSTEM 24 V DC Maximum system size 24 chambers or 1024 valves Indications: Graphic LC display Control elements: Foil keypad Real-time clock Resolution: 240 x 64 pixels Display area: 133 x 39 mm Colour: yellow-green Background illumination: LED 9 function keys 4 menu keys Numerical block Cursor block Date and time of which on the expansion Valve function monitoring Hose rupture detection Inputs: Master 32 x valve controller HE 5724 each with 32 outputs Electric and pneumatic With chamber sensor or central hose rupture detector, assignment to dedusting valve 4 x analogue 4...20 ma: differential and system pressure, central dust sensor, volume flow. 8 x digital: local remote switchover / fault acknowledgement / start / stop / post-cleaning Interfaces Profibus, Modbus, CANbus, serial interface Optional: Ethernet Slave: Outputs: 4 x analogue 4...20 ma: 2 x tank pressure and 2 x dust Casing: Control panel built-in casing Level of protection: front IP65, back IP20 Master 8 x digital: operation, cleaning, fault, pulse, lamp test, central shut-off valve Dimensions Ambient temperature Electrical connections 280 x 185 x 70 mm Operation: -10 C 55 C Storage: -25 C 60 C Transport: -25 C 85 C Screw plug terminals Slave 2 x digital: shut-off valves 96...230 V AC value voltage input Ambient temperature Operation: -10 C 50 C Option Operation: -40 C 60 C Process control communication PROFIBUS-DP, ModBus, Option: Ethernet with ModBus TCP on request Specification of the filter necessary on request CE, GOST-R (TR), UL Technical modifications reserved. 13

HE 5409 Differential Pressure Measuring Transducer The differential pressure measuring transducer HE 5409 is a universal measuring transducer for small and medium pressures. By fitting it with various pressure sensors, measuring ranges between 25 and 100 mbar can be realised. Two connection cables are used for the power supply. The feed current is the measurement signal from 4...20 ma. The operating state is indicated with an LED. TECHNICAL DATA (auxiliary energy) Measuring systems Medium Analogue output Max. admissible load Pressure connection U b =10 36 V DC Semi-conductor sensor Air as well as dry, non-aggressive gases 4...20 ma (two-wire technique) R A = (U b - 9 V) / 0.02 A Quick-action coupling: 6 mm HE 5409 0...25 mbar 54090025 1 HE 5409 0...50 mbar 54090050 1 HE 5409 0...100 mbar 54090100 1 Ambient temperature -20 C 55 C Versions: Plastic casing Electrical connection 88 x 88 x 53 mm Spring clamp terminals 0.2 1.5 mm² ATEX CE ATEX II 3D T60 C IP65 14 Technical modifications reserved.

HE 1149 Pressure Transmitter Strain gauge (DMS) measuring principle The pressure transmitter HE 1149 is used to record e.g. the system pressure in filter dedusting plants. It supplies a 4 20 ma signal. The pressure transmitter is used for monitoring pressure tanks as well as monitoring the function of solenoid valves. TECHNICAL DATA Measuring principle Thick-film strain gauge (DMS) HE 1149 63112xxx 1 Pressure ranges: bar 0...4 / 6 / 10 / 16 / 25 / 40 / 60 / 100-1...0.6 / 1.5 / 3 / 5 / 9 / 15 / 24 Example: HE 1149, 0...10 bar 63112010 1 Parts in contact with pressure 1.4305 and AL203 aluminium oxide ceramic Overload capacity 3 x nominal pressure 10...30 V DC Electrical connection Right-angle connector DIN 43650 with connection for 8 mm line Level of protection Analogue output IP65 (Option: IP67) 4...20 ma (2-wire) Total accuracy ±1.0 % Temperature error zero point Temperature error end value < 0.04 % / K < 0.04 % / K Temperature: Operation -40 C 125 C compensated -20 C 85 C Electrical connection Thread connection Right-angle connector DIN 43650 with connection for 8 mm line G ¼" ; others on request Casing material Stainless steel 1.4305 CE Technical modifications reserved. 15

HE 5410 Differential Pressure Measuring Transducer The differential pressure measuring transducer HE 5410 is a universal measuring transducer for small and medium pressures. By fitting it with various pressure sensors, measuring ranges between 2.5 and 1000 mbar can be realised. Two connection cables are used for the power supply. The feed current is the measurement signal from 4...20 ma. The operating state is indicated with an LED. TECHNICAL DATA 10...36 V DC HE 5410 541000xx 1 Operating temperature -10 C +50 C Measuring systems Semi-conductor sensor Medium Air as well as dry, non-aggressive gases Measuring range: Example: HE 5410, -5..-+5 mbar, 4 mm connection, Plastic Casing 54100051 1 mbar 0 2.5 / 5 / 10 / 25 / 50 / 100 / 250 / 500 / 1000 Pressure connection: Hose nipple Analogue output Accuracy: Basic accuracy Temperature drift Hysteresis Electrical connection Casing: For hose with 4 mm or 6 mm inside diameter 4...20 ma (two-wire technique) ± % of end value 0.005 % / K of end value ±0.5 % of end value Spring clamp terminals for conductors 0.2...1.5 mm² Plastic casing 88 x 88 x 53 mm (W x H x D) ATEX CE ATEX II 3D T60 C IP65 Zone 22 (plastic casing only) 16 Technical modifications reserved.

HE 5421 Differential Pressure Controller The HE 5421 is a universal measuring transducer especially for small differential pressures (<100 mbar). The actual differential pressure is indicated digitally with 3 ½-digits. The device has two switching thresholds for monitoring and control purposes, e.g. for the ΔP-dependent dedusting in industrial dust extraction technology. An additional alarm threshold is used for monitoring a maximum differential pressure. The switching state of the relays is indicated with LEDs. The device is dust-proof and approved for operation in Ex-Zone 22. TECHNICAL DATA Power consumption 230 V AC, 50...60 Hz, ±10 % Option: 115 V AC, 50...60 Hz, ±10 % Option: 24 V AC, -25 % / +10 %; 24 V DC, -15 % / +50 % 3 VA HE 5421 5421xxxx 1 Example: HE 5421, 24 V DC / 0 2.5 mbar / 4 20 m 54211112 1 Operating temperature -10 C +50 C Measuring system Medium Semi-conductor sensor Air as well as dry, non-aggressive gases Measuring range: mbar Pressure connection Analogue output Relay switching outputs: 1 change-over contact for cleaning 1 change-over contact for ΔP-alarm Pressure connection Accuracy: Basic accuracy 0 25 / 30 / 40 / 50 / 70 / 100 / 500 other measuring ranges on request Pipe connection G ¼" internal thread Option: 4 mm, 6 mm hose nipple 0(4) 20 ma or 0 10 V Contact load 250 V AC, 5 A or 120 V DC, 1 A Contact load 250 V AC, 5 A or 120 V DC, 1 A Pipe connection G ¼" internal, hose nipple ±1 % of end value Temperature drift ±0.05 % / K of end value CE Hysteresis Electrical connections ±0.5 % of end value Spring clamp terminals 1.0 mm² finely stranded, 1.5 mm² single stranded ATEX ATEX II 3D T60 C IP65 Zone 22 (plastic casing only) Casing: Plastic casing (IP65) 122 x 120 x 55 mm (W x H x D) Technical modifications reserved. 17

ADAPTERS, CONNECTORS, CONNEC- TIONS, INTERCONNECTIONS Connection Accessories for Solenoid Valve Controllers Differential Pressure Connection Set ORDERING DATA Connection Set (Screwed Cable Gland) up to 12 Valves Main Cabling for 12 Valves, 1 m length Main Cable for 12 Valves, linear metre Valve Cable 2.50 m with DIN 43650 Connector Valve Cable 5.20 m with DIN 43650 Connector Connection Set HE 5731 (Screwed Cable Glands) ORDER NUMBER # 57 29 20 # 57 29 90 # 57 29 95 # 57310097 # 57310098 # 57310099 Connection set for differential pressure measurement on crude gas and clean gas line (for HE 54xx and P valve controllers). The secure hose connection to the crude- and clean gas side of a filter is simplified by the connection set. The connections to the measuring equipment are established with two hose lines with 4 mm inside diameter. Differential Pressure Connection Set 54109999 1 18 Technical modifications reserved.

NOTES HESCH Your Automation Partner 19

HESCH Industrie-Elektronik GmbH Boschstraße 8 D-31535 Neustadt Telephone +49 5032 9535-0 Fax +49 5032 9535-99 E-mail info@hesch.de Internet www.hesch.de Alterations reserved 11/2011 Version 1