BFS-10-O G1/4: BFS-10-O G1/2: BFS-10-O G1: Contact rating: BFS-10-O G1/4

Similar documents
Flow switches Series AD/VH

Metal tube flowmeters Series M21 Variable area flowmeter for low flows of liquids, gases and steam

Metal tube variable area flowmeter for gases, liquids and steam

Glass tube flowmeters Series 6000 Variable area flowmeter for liquids and gases

Metal tube flowmeters. Series SC250. Metal Tube Flow Meters. Series SC250. Variable area flowmeter for liquids, gases and steam

Orifice plate flowmeters Series PR By-pass flowmeter for liquids, gases and steam

Level switches Series LC40 Float level switch for liquids

FLOW. control. switch measure. Flow Switches

Oscillating piston flowmeters Series COVOL Positive displacement flowmeter for liquids

Plastic tube variable area flowmeter for liquids and gases

Flowmeters with Float. Flow Measurement of Gases & Clear Liquids with Float Series 6001 & Series 6001/ Measurement Principle.

Turbine flowmeters Series TM

Electromagnetic flowmeters Series FLOMAT Insertion electromagnetic flowmeter for conductive liquids

Instructions Manual. Target Disk Flow meter DP-65 / DP-500. Series DP-65 DP-500. instrumentation for fluids

XMP ci. Process Pressure Transmitter with HART -communication. Ceramic Sensor. accuracy according to IEC 60770: 0.1 % FSO.

Flap-Type Flow Meter Prall

Design and application

INLINE Flow sensor for hazardous area II 1 G/D - II 2 D - II 3 GD - I M1

Magnetic float switch For vertical installation Model FLS (models with Ex approval: 60, AL-ADF)

BGN. All Metal Variable Area Flow Meter. Technical Data Sheet

DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor

Electromagnetic flowmeters Series FLOMID Electromagnetic flowmeter for conductive liquids

Shipbuilding solutions

DMP 333. Industrial Pressure Transmitter For High Pressure. Stainless Steel Sensor

DMK 331P. Industrial Pressure Transmitter. Pressure Ports With Flush Welded Stainless Steel Diaphragm

Intrinsically safe presure transmitters for hazardous environments Type MBS 4201, MBS 4251, MBS 4701 and MBS Technical brochure

Absolute pressure gauge with diaphragm

DMK 331P. Industrial Pressure Transmitter. Pressure Ports With Flush Welded Stainless Steel Diaphragm. accuracy according to IEC 60770: 0.

OPTISWITCH 4000/5000. Vibration level switches for liquids

For industrial applications For marine applications With proximity switch. Piston type flow switches

Magnetic-inductive flow meter for hazardous areas

DMP 331 DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor. Pressure Transmitter. Industrial

Model Connections Max. Flow Range (H 2 O) 10A A3220 Horizontal ¼ NPT 100 l/h. 10A3225/55 Vertical ¼ NPT 100 l/h. Vertical 1 NPT Vertical 1 G

SATRON VDt Differential Pressure Transmitter

3/2-, 5/2- and 5/3-way Solenoid Valves for process pneumatics

DMP 331P. Industrial Pressure Transmitter. Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm

Electropneumatic positioner APIS

Fluid Power Fluid Power

Differential-Pressure Flow Meter

SATRON VT Pressure Transmitter

Plastic Flow Meters for gases & liquids, using TROGAMID* & POLYSULFONE Technology

flow switches J with pipe tees (inline) J Direct installation (insertion) J for hvac applications J with interchangeable paddles J For air flow

DG01. Flow indicator with or without rotor, with wiper for cleaning of sight glass. Flow Metering and Monitoring Systems

LMK 387. Stainless Steel Probe. Ceramic Sensor. accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % FSO

Type 2511/12. Type Type 2030 Cable plug. ASI cable plug. Dosing control. General technical data Orifice Type 6518

display on the wall or in a panel away from the inline sensor SE30 for easy meter reading.

3/2-, 5/2- and 5/3-way Solenoid Valves for process pneumatics

Differential pressure gauge with diaphragm

TORRIX Magnetostrictive level sensor

Magnetic Float Switches horizontal 1003-h

Pressure Transmitter

High temperature pressure transmitters for heavy-duty applications MBS 2200 and MBS 2250

15 mm Pilot Valve. More technical specifications are reported in the following pages. 1

DMK 331P DMK 331P. Industrial Pressure Transmitter. Pressure Ports With Flush Welded Stainless Steel Diaphragm. Pressure Transmitter.

Level instruments. Continuous level measurement - Capacitance transmitters SITRANS LC300. 5/262 Siemens FI Overview.

A Higher Level of Performance. Data Sheet. Centurion. Guided Radar. CGR Series. For more information, please visit >

Differential Pressure and Flow meters Accessories for the Media Series

DMP 331P DMP 331P. Industrial Pressure Transmitter. Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm

A Higher Level of Performance. Data Sheet. Centurion. Guided Radar. CGR Series. For more information, please visit >

Application The DA03 serves as indicator of differential. Follow mounting instructions in accordance to application.

Reliable - Safe - Proven!

DPT 200. Differential Pressure Transmitter for Process Industry with HART -Communication. accuracy according to IEC 60770: 0.

PSF50 Paddle flow switch

FLOW SWITCHES. With pipe tees (inline) Direct installation (insertion) For OEM applications Flow monitors. Including products with:

BM 26 BASIC/ADVANCED Technical Datasheet

Pressure transmitters for heavy duty applications MBS 3200 and 3250

HERION SERIES Indirect solenoid actuated soft seal

Pressure transmitters for heavy-duty applications MBS 2000 and MBS 2050

JUMO dtrans p20. Process pressure transmitter. Type Brief description. Key features. Block diagram

System 6000 Electropneumatic Converter for Direct Current Signals Type 6116 i/p Converter

,

Variable Area Flowmeters Armored Purgemeter

SIKA Flow Switches -1-

General Specifications

2/2-way Globe Valve for media up to +180 C, DN

Pressure transmitter for general industrial purposes MBS 3000 and MBS 3050

V82 series - Redundant valve manifold systems - Compact 1oo2 Safety, 2oo2 Availability and 2oo3 Safety and Availability

3/2, 5/2, 5/2 bistable and 5/3 way pneumatic solenoid valve

GA 24 Heavy-duty variable area flowmeter

Pressure transducer DMU 01K Compact version

2/2-way Angle-Seat Valve for medium up to +180 C, threaded port connection, DN 15-65

PRESSURE TRANSMITTER PYRP-28 INDUSTRIAL & INTRINSICALLY SAFE PRESSURE TRANSMITTER PRESSURE TRANSMITTER

SITRANS P measuring instruments for pressure

Magnetic float switch For vertical installation Model FLS

JUMO dtrans p20 DELTA

VFM4070C SWIRLMAX. Vortex Flowmeter OUTLINE FEATURES OPERATING PRINCIPLE STANDARED SPECIFICATION. General Specification. Sensor Specification

Temperature sensor TE2

Direct-acting 3/2 way plunger valve

Data Sheet SCHISCHEK EXCOS-P. Pressure sensor 20 Pa Pa. Supplied by. .com. Call us on +44 (0)

ExBin-P Pressure switches 5 Pa Pa

SATRON VVFe Pressure Transmitter

SP/SF Series Flow Switches

Design and applications

OEM Pressure transmitter for industrial applications Type MBS Technical brochure

Material pressure (bar) (Cv (US) kv x 1,2 Seat. N/en

2/2-way-Globe Valve with stainless steel design for media up to +180ºC, DN 13-50

BM 26 BASIC/ADVANCED Technical Datasheet

KINAX SR 709 Transmitter for Position Feedback

* * Data sheet DA A (ATEX) Differential pressure measuring device for potentially explosive areas

Versions. Version with K VS Version with K VS 2.0. Fig. 1: Type 3967 Solenoid Valve

Transcription:

Flow Switches Index: B / 923-1838 BFS-10-N / BFS-10-O for monitoring liquids, with or without optical display Features set point continuously adjustable rugged, low hysteresis, any mounting position, high accuracy and functional safety Measuring ranges 0,005...0,06 l/min to 60...150 l/min for water Applications Measuring and monitoring of liquids, e. g. in cooling systems, test beds, pumps etc. BFS-10-N (without indication) Measuring principle: Var. aera flow meter: Housing: Magnets: BFS-10-N G1/4: BFS-10-N G1/2: BFS-10-N G1: version, nickel-plated, nickel-plated PN 300 bar PN 300 bar PN 250 bar Accuracy: ±10% f. s. SS 350 bar 350 bar 300 bar 100 C (standard), 160 C (option HT) Pressure drop 0,02...0,2 bar 0,02...0,3 bar 0,02...0,4 bar Electrical connection: plug acc. to DIN EN 175301-803 (DIN BFS-10-N G1/4 BFS-10-N G1/2 BFS-10-N G1 (water in l/min) 200 V / 1 A / 20 VA 200 V / 1 A / 20 VA 230 V / 3 A / 60 VA IP65 (plug acc. to DIN EN 175301-803 formaly DIN e.g. ATEX, see www.barksdale.de BFS-10-N G1/4: BFS-10-N G1/2: BFS-10-N G1: 0,005...0,06 0,02...0,2 10...30 0,04...0,13 0,2...0,6 15...45 0,1...0,6 0,4...1,8 20...60 0,2...1,2 0,8...3,2 30...90 0,4...2,0 2,0...7,0 60...150 0,5...3,0 3,0...13 1,0...5,0 4,0...20 8,0...30 BFS-10-O (with optical indication) Measuring principle: Var. aera flow meter: Display Housing: Glass: Magnets: BFS-10-O G1/4: BFS-10-O G1/2: BFS-10-O G1: version, nickel-plated alumin., anodized Duran 50 PN 16 bar PN 16 bar PN 10 bar Accuracy: ±10% f. s. Electrical connection: BFS-10-O G1/4 BFS-10-O G1/2 BFS-10-O G1 (water in l/min) alumin., anodized Duran 50 SS 16 bar 16 bar 10 bar 100 C (standard), 160 C (option HT) Pressure drop 0,02...0,2 bar 0,02...0,3 bar 0,02...0,4 bar plug acc. to DIN EN 175301-803 (formaly DIN 200 V / 1 A / 20 VA 200 V / 1 A / 20 VA 230 V / 3 A / 60 VA IP65 (plug acc. to DIN EN 175301-803 formaly DIN e.g. ATEX, see www.barksdale.de BFS-10-O G1/4: BFS-10-O G1/2: BFS-10-O G1: 0,005...0,06 0,2...0,5 8,0 20 8,0...30 0,025...0,13 0,3...1,0 9,5 24 15...45 0,1...0,6 0,7 2,0 12 28 30...90 0,2...1,2 1,6...4,0 60...150 0,4...2,0 3,0...8,0 0,5...3,0 4,5...12 1,0...5,0 6,0 15 Barksdale Subject to technical changes. 1

Flow Switches Flow BFS-10-N / BFS-10-O Dimensions (mm / inch) Order Numbers BFS-10-N BFS-10-O Brass Brass 0711-256 BFS-10-N-G1/4-MS-NO-ST 0711-250 BFS-10-O-G1/4-MS-NO-ST 0711-338 BFS-10-N-G1/4-MS-WE-ST 0711-332 BFS-10-O-G1/4-MS-WE-ST 0711-257 BFS-10-N-G1/2-MS-NO-ST 0711-347 BFS-10-O-G1/2-MS-NO-ST 0711-339 BFS-10-N-G1/2-MS-WE-ST 0711-348 BFS-10-O-G1/2-MS-WE-ST 0711-258 BFS-10-N-G1-MS-NO-ST 0711-252 BFS-10-O-G1-MS-NO-ST 0711-340 BFS-10-N-G1-MS-WE-ST 0711-334 BFS-10-O-G1-MS-WE-ST Stainless Steel Stainless Steel 0711-259 BFS-10-N-G1/4-SS-NO-ST 0711-253 BFS-10-O-G1/4-SS-NO-ST 0711-341 BFS-10-N-G1/4-SS-WE-ST 0711-335 BFS-10-O-G1/4-SS-WE-ST 0711-260 BFS-10-N-G1/2-SS-NO-ST 0711-349 BFS-10-O-G1/2-SS-NO-ST 0711-342 BFS-10-N-G1/2-SS-WE-ST 0711-350 BFS-10-O-G1/2-SS-WE-ST 0711-261 BFS-10-N-G1-SS-NO-ST 0711-255 BFS-10-O-G1-SS-NO-ST 0711-343 BFS-10-N-G1-SS-WE-ST 0711-337 BFS-10-O-G1-SS-WE-ST Order number example: Order number + switching range = 0711-339, 2,0...7,0 l/min Description NO = normally open O = with indication MS = WE = change-over N = without indication SS = stainless steel Please specify switching range (see table on page previous) additional to order number. 2 Subject to technical changes. Barksdale

Index: A / 923-1854 Flow Switches BFS-20-O / BFS-20-OL for liquids from 30 up to 600 cst with optical display Features viscosity compensated from 30 to 600 cst, set point continuously adjustable, rugged, low hysteresis, any mounting position, high accuracy and functional safety, with 1/2" connection also available as low cost version Measuring ranges 0,1... 0,8 l/min to 30... 90 l/min for liquids up from 30 to 600 cst. Applications Measuring and monitoring of liquids, e. g. in cooling or hydraulic systems, test beds, pumps etc. BFS-20-O BFS-20-OL Measuring principle: Measuring principle: Flow meter: Display Housing: Glass: Magnets: version, nickel-plated alumin, anodized Duran 50 alumin, anodized Duran 50 Flow meter: Display Housing: Glass: Magnets: version, nickel-plated, nickel-plated alumin, anodized Duran 50 alumin, anodized Duran 50 BFS-20-O: PN 10 bar VA 10 bar BFS-20-OL: PN 16 bar VA 16 bar 120 C (standard), 160 C (option HT) 120 C (standard), 160 C (option HT) Accuracy: ±10% f. s. Accuracy: ±10% f. s. Electrical connection: plug acc. to DIN EN 175301-803-C (Ex DIN Electrical connection: plug acc. to DIN EN 175301-803-C (Ex DIN BFS-20-O G1 Pressure drop 0,02...0,4 bar BFS-20-OL G1 Pressure drop 0,2...0,4 bar IP65 (plug acc. to DIN EN 175301-803-C - Ex DIN IP65 (plug acc. to DIN EN 175301-803-C - Ex DIN e.g. ATEX, see www.barksdale.de e.g. ATEX, see www.barksdale.de (air in Nl/min) BFS-20-O G1/4: in l/min BFS-20-O G1/2: BFS-20-O G3/4: BFS-20-O G1: 0,5 1,5 BFS-20-OL G1/2: 0,5 1,7 1,0 4,0 1,3 4,0 2,0 8 2,5 8,0 3,0 10 5,0 15 8,0 24 10 30 15 45 20 60 30 90 Barksdale Subject to technical changes. 1

Flow Flow Switches BFS-20-O / BFS-20-OL Dimensions (mm / inch) Order Code BFS-20-O BFS-20-OL Brass Brass 0712-263 BFS-20-O-G1-MS-NO-ST 0712-262 BFS-20-OL-G1/2-MS-NO-ST 0712-345 BFS-20-O-G1-MS-WE-ST 0712-344 BFS-20-OL-G1/2-MS-WE-ST Stainless Steel Stainless Steel 0712-265 BFS-20-O-G1-SS-NO-ST 0712-264 BFS-20-OL-G1/2-SS-NO-ST 0712-347 BFS-20-O-G1-SS-WE-ST 0712-346 BFS-20-OL-G1/2-SS-WE-ST The version BFS-20-O is also available with process connections, please see table on side before. To place an order please add the process connection to the order number. Order number example: Order number + switching range = 0712-263, 3 10 l/min Description NO = normally open O = with indication MS = WE = change-over N = without indication SS = stainless steel 2 Subject to technical changes. Please specify switching range (see table on page previous) additional to order number. Barksdale

Index: C / 923-1858 Flow Switches BFS-40-N / BFS-40-O or water monitoring,with or without optical display Features large switching range, set point continuously adjustable, rugged, low hysteresis, any mounting position, high accuracy and functional safety, optional with pointer-indicating instrument, ship approvals available for N-versions Measuring ranges 0,2...4,0 l/min to 35...250 l/min for water Applications Measuring and monitoring of liquids, e. g. in cooling or hydraulic systems, test beds, pumps etc. BFS-40-N (without optical indication) BFS-40-O (with optical indication) Measuring principle: Measuring principle: Var. aera flow meter: Housing: version, nickel-plated, nickel-plated Var. aera flow meter: Housing: Display Housing: version, nickel-plated, nickel-plated makrolon makrolon BFS-40-N 200 bar VA 300 bar BFS-40-O: 200 bar VA 300 bar 100 C (standard), 160 C (option HT) 100 C (standard), 160 C (option HT) Accuracy: ±5% f. s. Accuracy: ±5% f. s. Electrical connection: plug acc. to DIN EN 175301-803-C (Ex DIN Electrical connection: plug acc. to DIN EN 175301-803-C (Ex DIN BFS-40-N GL 100 bar Pressure drop 0,02...0,8 bar BFS-40-O IP65 (plug acc. to DIN EN 175301-803-C - Ex DIN e.g. ATEX, GL, BV,...see www.barksdale.de IP65 (plug acc. to DIN EN 175301-803-C - Ex DIN see www.barksdale.de in l/min in l/min BFS-40N G1/4: Pressure drop 0,02...0,8 bar BFS-40N G1/2: BFS-40N G3/4: BFS-40N G1: BFS-40- BFS-40N G1 1/4: N G1 1/2: BFS-40O G1/4: BFS-40O G1/2: 0,2 4,0 0,2 4,0 0,5 8,0 0,5 8,0 0,6 5,0 0,6 5,0 1,0 14 1,0 14 1,0 28 1,0 28 BFS-40O G1: BFS-40- BFS-40O G1 1/4: O G1 1/2: 2,0 40 2,0 40 4,0 55 4,0 55 1,0 70 1,0 70 8,0 90 8,0 90 5,0 110 5,0 110 10 150 Barksdale BFS-40O G3/4: 10 150 35 220 35 220 35 250 Subject to technical changes. 35 250 1

Flow Flow Switches BFS-40-N / BFS-40-O Dimensions (mm / inch) Pressure Drop Diagram Wiring Diagrams Order Numbers Order numbers on request 2 Subject to technical changes. Barksdale

Flow Switches Index: C / 923-1856 BFS-30-N / BFS-30-O or liquids from 30 up to 600 cst, with or without optical display Features viscosity compensated from 30 up to 600 cst, set point continuously adjustable, rugged, low hysteresis, any mounting position, high accuracy and functional safety, optional with pointer-indicating instrument, ship approvals available for N-versions Measuring ranges 0.5...1.5 l/min to 35...110 l/min for liquids from 30 up to 600 cst. Applications Measuring and monitoring of liquids, e. g. in cooling or hydraulic systems, test beds, pumps etc. BFS-30-N (without indication) Measuring principle: Flow meter: Housing: BFS-30-N, N E: BFS-30-L: version, nickel-plated, nickel-plated 250 bar 300 bar Accuracy: ±10% f. s. Electrical connection: BFS-30-L BFS-30-N, N E GL 100 bar 100 bar VA 300 bar 350 bar 120 C (standard), 160 C (option HT) Press.drop 0,02...0,4 bar 0,02...0,2 bar plug acc. to DIN EN 175301-803 (Ex DIN 230 V / 3 A / 60 VA IP65 (plug acc. to DIN EN 175301-803 - Ex DIN e.g. ATEX, GL, BV,...see www.barksdale.de versions water in l/min Process connections BFS-30-L: BFS-30-N: BFS-30-N E: 0,5 1,6 0,8 3,0 / 2,0 7,0 0,5...1,5 / 1,0...4,0 2,0...8,0 / 3,0...10 5,0...15 / 8,0...24 10...30 / 15...45 20...60 / 30...90 35...110 1,0...20 / 4,0...40 5,0...50 / 8,0...60 12...70 / 15...80 G1/2 G1 BFS-30-O (with optical indication) Measuring principle: Flow meter: Housing: Display Housing: BFS-30-O, O E: version, nickel-plated, nickel-plated Makrolon 250 bar Accuracy: ±10% f. s. Electrical connection: BFS-30-O, O E Makrolon VA 300 bar 120 C (standard), 160 C (option HT) Press. drop 0,02...0,4 bar plug acc. to DIN EN 175301-803 (Ex DIN IP65 (plug acc. to DIN EN 175301-803 - Ex DIN see www.barksdale.de versions water in l/min Process connection BFS-30-O: BFS-30-O E: 0,5...1,5 / 1,0...4,0 2,0...8,0 / 3,0...10 5,0...15 / 8,0...24 10...30 / 15...45 20...60 / 30...90 35...110 1,0...20 / 4,0...40 5,0...50 / 8,0...60 12...70 / 15...80 G1 G1 Barksdale Subject to technical changes. 1

Flow Flow Switches BFS-30-N / BFS-30-O Dimensions (mm / inch) Order Code Brass Description Stainless Steel Description 0713-266 BFS-30-L-G1/2-MS-NO-ST 0713-269 BFS-30-L-G1/2-SS-NO-ST 0713-267 BFS-30-N-G1-MS-NO-ST 0713-270 BFS-30-N-G1-SS-NO-ST 0713-268 BFS-30-NE-G1-MS-NO-ST 0713-271 BFS-30-NE-G1-SS-NO-ST 0713-272 BFS-30-O-G1-MS-NO-ST 0713-274 BFS-30-O-G1-SS-NO-ST 0713-273 BFS-30-OE-G1-MS-NO-ST 0713-275 BFS-30-OE-G1-SS-NO-ST 0713-348 BFS-30-L-G1/2-MS-WE-ST 0713-351 BFS-30-L-G1/2-SS-WE-ST 0713-349 BFS-30-N-G1-MS-WE-ST 0713-352 BFS-30-N-G1-SS-WE-ST 0713-350 BFS-30-NE-G1-MS-WE-ST 0713-353 BFS-30-NE-G1-SS-WE-ST 0713-354 BFS-30-O-G1-MS-WE-ST 0713-356 BFS-30-O-G1-SS-WE-ST 0713-355 BFS-30-OE-G1-MS-WE-ST 0713-357 BFS-30-OE-G1-SS-WE-ST Brass Process connection Stainless Steel Process connection 0799-026 1...1/4 0799-029 1...1/4 0799-027 1...1/2 0799-030 1...1/2 0799-028 1...3/4 0799-031 1...3/4 Adapter Order number example: Order number + switching range = 0713-266, 0,8...3,0 l/min Description NO = normally open NE = without indication, enlarged meas. range WE = change-over OE = with indication enlarged meas. range Please specify switching range (see table on page previous) additional SS = stainless steel to order number. MS = L = without indication, low cost O = with indication N = without indication 2 Subject to technical changes. Barksdale

Flow switch and indicator for liquids and gases Suitable for clear, opaque or turbid liquids (series AD & VH), and for gases (series AD) Flow switching by means of magnetic coupling, watertight, no contact between process fluid and switching, indicator or transmitter systems Suitable for installation in horizontal or vertical pipes Robust construction Scales available for H 2 O, air, oil, etc. (series AD) Flow rate (for liquids): - Series AD: 0.25... 270 l/min - Series VH: 2... 120 m 3 /h Accuracy for series AD: ±5% f.s. Connections: - Series AD: ¼... 2½ BSP / NPT - Series VH: G1 / 1 NPT, to be inserted on a DN32... DN500 pipe - Series AD: EN 1.4404 (SS 316L), aluminium, - Series VH: EN 1.4404 (SS 316L), PTFE Flow switching: - 1 reed switch (series AD & VH) - 2 reed switches (only series AD) - 1 or 2 inductive switches (only series AD) All switches for series AD are ATEX Ex ia IIC T4...T6 Ga / Ex ia IIIC T85ºC Da certified Options for model ADI15: - Local flow indication - Electronic transmitter with 4-20 ma output for safe or hazardous area (Ex ia IIC T4...T6 Ga / Ex ia IIIC T85ºC Da protection, ATEX certified). HART TM protocol available on request

Series AD Working principle A spring M keeps a disk B in zero flow rate position. When the fluid flows through the disk at a specific speed, a force is made on the disk B, moving it to an equilibrium position. The distance covered by B depends on: - The force of the fluid flow F. - The relationship between areas A & B. - The force in opposition of the spring C. The equilibrium between forces F and the one generated by C defines the position of the disk B, equivalent to flow rate. The disk B, which contains a magnet M, acts over the switches and/or the local indicator. Applications Machine or processes cooling Hydraulic and lubrication circuits Thermal oil circuits Gas flow control Mechanical fasteners cooling control Technical data Accuracy: ±5% full scale Scale range: according to flow rate chart on page 4 Scales in l/h, l/min, l/s, m 3 /h, %, etc. Vertical or horizontal mounting, as per customer s request Connection: ¼... 2½ BSP / NPT Brass from ¼ to 2 Aluminium from 1 ¼ to 2 ½ EN 1.4404 (SS 316L) on request Fluid temperature: continuous 100ºC (max. allowable 120ºC) Working pressure: PN16 (others on request) Ex ia IIC T4...T6 Ga / Ex ia IIIC T85ºC Da ATEX certificate Operation - Vertical flow: upwards (BD) downwards (DAB) - Horizontal flow: left to right (ED) right to left (DES) Limit switches and transmitters Reed switches: SPDT potential free. Polyamide housing and IP65 connector /1A = 1 reed switch /2A = 2 reed switches Reed switch technical data: - ADR01: for sizes ¼ & ½ : 0,25 A 175 VDC 5 W - ADR11: for sizes ¾ to 2½ : 1 A 250 V 60 VA M1-AMD1... 2: 1... 2 adjustable inductive switches (+ relays on request) TH6... TH6H: 4-20 ma 2-wire transmitter HART TM protocol for model TH6H All switches and transmitters are ATEX available Ex ia IIC T4...T6 Ga / Ex ia IIIC T85ºC Da version Models AD15: with one or two reed switches ADI15: local flow indication optionally with: - one or two reed switches - one or two inductive switches - 4-20 ma transmitter Transmitter TH6 2

Materials ¼... 1 1¼... 2½ Nº Description ¼... 1 1 ¼... 2 ½ 1 Body Brass / SS 316L / Anodized aluminium * 2 Disk 3 Magnet Ferrite ** 4 Switch Polycarbonate - PVC - NBR 5 Washer SS 316L 6 Spring SS 302 7 Housing Polycarbonate - Coated aluminium 8 Screw SS 316 9 Gasket NBR *** * Materials available for each size: ¼... 1 :, SS 316L 1 ¼ 2 :, SS 316L, anodized aluminium 2 ½ : SS 316L, anodized aluminium ** magnet with plastic coating for applications with corrosive liquids on request *** other materials on request 3

Dimensions Flow ranges R (BSP / NPT) Flow scales l/min water AD15 ADI15 ¼ ½ 0.25-1 0.5-2.5 1-5 1.5-10 2-17 ¾ 5-30 6-40 1" 10-50 1 ¼" 15-70 1 ½ 40-160 2" 70-220 2 ½" 100-270 *Equivalent flow ranges for air at 1 bar abs 20ºC in Nl/min: l/min H 2 O x 8 (approx.) Mounting Vertical upwards Models AD15/BD ADI15/BD ADI15+TH6 Vertical downwards Models AD15/DAB ADI15/DAB R (BSP / NPT) A B C F L Weight kg mm ¼ 30 14 85 70 151 0.9 ½ 30 14 85 70 151 1.2 ¾ 40 15 95 75 169 1.6 1" 40 15 95 75 169 1.8 1 ¼" 50 27 105 80 160 2.4 1 ½ 60 27 115 85 180 3 2" Ø 80 37 134 96 200 3.2 2 ½" Ø 100 37 147 97 200 3.6 Horizontal / Left to right Models Horizontal / Right to left Models AD15/ED ADI15/ED AD15/DES ADI15/DES 4

Model AD15 Flow switch with min-max flow rate reed switches. Vertical or horizontal mounting, as per customer s request. Adjustable reed switch for the full flow scale, mounted in a polyamide housing, IP65 ingress protection. Flow scale in l/h, l/min, l/s, m 3 /h, %, etc. Model ADI15 Local flow indicator, with optional min-max flow rate reed switches, adjustable for the full flow scale and mounted in an IP65 polyamide housing; and/or adjustable inductive switches, mounted in the indicator housing. Vertical or horizontal mounting, as per customer s request. Aluminium indicator housing with polycarbonate cover, IP65 ingress protection, graduated scale in flow rate units, reading by means of indicating needle. Flow and reed switch scale in l/h, l/min, l/s, m 3 /h, %, etc. Model ADI15 + TH6 Same characteristics as model ADI15, including electronic transmitter with 2-wire 4-20 ma output. Limit switches and transmitters Adjustable limit switch M1-AMD Optional for model ADI15. NAMUR (EN 60947-5-6) 3.5 mm slot type inductive detector activated by vane, mounted in the indicator housing. M1-AMD1 2: 1 2 adjustable limit switches Power supply: 8 VDC Ambient temperature: -25 C... +70 C ATEX certification Ex ia IIC T4...T6 Ga / Ex ia IIIC T85ºC Da Control relay (on request) NAMUR (EN 60947-5-6) for 1 or 2 inductive detectors. Power supply: 24 253 VAC 50-60 Hz 24 300 VDC Input: NAMUR Ex ia IIC Output: 1 or 2 relay contacts Output rating: 2 A 250 VAC 100 VA / 1 A 24 VDC Ambient temperature: -20 C... +60 C Transmitter TH6 4-20 ma Power supply: 2-wire system, 12 36 VDC Power consumption: max. 20 ma Analog output (4-20 ma): - Error: < 0,6% of the magnet position - Maximum load in 4-20 ma loop: 1.1 kω (with 36 VDC power supply) Ambient temperature: -5ºC... +70ºC Transmitter connector: Packing gland M12x1.5 Optional: ATEX certification Ex ia IIC T4...T6 Ga / Ex ia IIIC T85ºC Da, with model TH6 Ex Optional: HART TM protocol, with model TH6H 5

Series VH Working principle A liquid flows inside a pipe fast enough to move a paddle, which at the same time moves a permanent magnet that acts over the reed switch. The magnet-reed switch system is isolated from the liquid. The flow switching point is positioned between 30º and 45º from the zero position. Materials Applications Flow rate control in hydraulic and heating-cooling circuits Chemical and petrochemical industry Water treatment, power plants and pulp & paper industry Swimming pools & fire protection systems Technical data Flow detection by means of oscillating paddle SPDT potential free reed switch, mounted in the body, not wetted by the liquid Mounting: horizontal or vertical upwards pipe Connection: G1 (1 NPT on request) EN 1.4404 (SS 316L), PTFE others on request Fluid temperature: continuous -40ºC... +125ºC (max. allowable 150ºC) Working pressure: - SS 316L body: PN25 (others on request) - PTFE body: PN10 Operation - Vertical upwards flow (BD) - Horizontal flow: left to right right to left Models VH35 / SS... PTFE: for horizontal pipe VH37 / SS BD: for vertical pipe with upwards flow, with spring VH39 / PTFE BD: for vertical pipe with upwards flow, with magnetic spring Limit switch Reed switch: potential free switch Maximum switching power: 5W Maximum switching voltage: 175 VDC Maximum switching current: 0.25 A Electrical connection: connector IP65 DIN 43 650-A Simple apparatus according to EN-60079-11 standard. Intrinsically safe i protection for ATEX hazardous areas Nº Description VH / SS VH / PTFE 1 Connector Polyamide 2 Screw SS 304 3 Gasket NBR 4 Connector base Polyamide 5 Gasket NBR 6 Spring SS 304 7 Body SS 316L PTFE 8 Magnet holder PVDF PTFE 9 Reed switch Glass 10 Pin SS 316 PTFE 11 Paddle SS 316L PTFE 6

Dimensions Switching flow rates DN mm DN inch Switching flow rate (1) m³/h L mm 32 1 ¼ 2 26 40 1 ½ 2.5 34 50 2 3 40 65 2 ½ 4 55 80 3 5 65 100 4 10 90 125 5 10 115 150 6 12 140 200 8 25 185 250 10 30 230 300 12 50 280 350 14 60 330 400 16 80 380 450 18 100 415 500 20 120 450 (1) Approximate flow rates Mounting Horizontal / left to right or right to left: model VH35 VH35 / SS VH35 / SS VH35 / PTFE Vertical upwards: model VH37 / 39 BD VH37 / SS BD VH35 / PTFE VH39 / PTFE BD 7

...presence in more than 50 countries around the world Quality Assurance System ISO 9001 certified by Pressure Equipment Directive 97/23/CE certified by ATEX Directive 94/9/CE certified by R-CT-ADVH Rev. 0 english version

Flow Switches Index: A / 923-1852 Type BFS-10-N-AIR / BFS-10- O-AIR for monitoring volume flow of gaseous media, with or without optical display Features set point continuously adjustable, rugged, low hysteresis, any mounting position, high accuracy and functional safety Measuring ranges 0,2...1,3 Nl/min to 200...650 Nl/min for air Applications Measuring and monitoring of gaseous media, e. g. in cooling systems, test beds, pumps etc. BFS-10-N-AIR (without indication) Measuring principle: Var. aera flow meter: Housing: Magnets: BFS-10-N G1/4: BFS-10-N G1/2: BFS-10-N G1: version, nickel-plated, nickel-plated PN 300 bar PN 300 bar PN 250 bar Accuracy: ±10% f. s. Electrical connection: BFS-10-N-AIR G1/4 BFS-10-N-AIR G1/2 BFS-10-N-AIR G1 (air in Nl/min) VA 350 bar 350 bar 300 bar 100 C (standard), 160 C (option HT) Pressure drop 0,02...0,2 bar 0,02...0,3 bar 0,02...0,4 bar plug acc. to DIN EN 175301-803-C (Ex DIN 200 V / 1 A / 20 VA 200 V / 1 A / 20 VA 230 V / 3 A / 60 VA IP65 (plug acc. to DIN EN 175301-803-C - Ex DIN e.g. ATEX, see www.barksdale.de BFS-10-N-AIR G1/4: BFS-10-N-AIR G1/2: BFS-10-N-AIR G1: 0,6 2,2 2,5 10 60 180 1,7 6,0 5,5 20 100 300 2,5 8,0 8,0 30 200 650 3,0 12 10 35 3,0 22 24 90 7,0 24 55 220 12 34 65 240 16 56 80 300 20 80 140 525 BFS-10-O-AIR (with optical indication) Measuring principle: Var. aera flow meter: Display Housing: Glass: Magnets: BFS-10-O G1/4: BFS-10-O G1/2: BFS-10-O G1: version, nickel-plated alumin., anodized Duran 50 PN 16 bar PN 16 bar PN 10 bar Accuracy: ±10% f. s. Electrical connection: BFS-10-O-AIR G1/4 BFS-10-O-AIR G1/2 BFS-10-O-AIR G1 (air in NL/min) for: alumin., anodized Duran 50 VA 16 bar 16 bar 10 bar 100 C (standard), 160 C (option HT) Pressure drop 0,02...0,2 bar 0,02...0,3 bar 0,02...0,4 bar plug acc. to DIN EN 175301-803-C (Ex DIN 200 V / 1 A / 20 VA 200 V / 1 A / 20 VA 230 V / 3 A / 60 VA IP65 (plug acc. to DIN EN 175301-803-C - Ex DIN e.g. ATEX, see www.barksdale.de BFS-10-O-AIR G1/4: BFS-10-O-AIR G1/2: BFS-10-O-AIR G1: 0,2 1,3 5,5 20 3,0 12 22,5 80 0,5 2,0 7,0 24 7,0 30 50 130 0,8 3,0 10 35 12 40 130 420 1,5 5,0 10 42 28 125 200 625 2,0 8,0 50 200 3,0 12 100 420 3,5 14 120 480 Barksdale Subject to technical changes. 1

Flow Switches Flow Type BFS-10-N-AIR / BFS-10- O-AIR Dimensions (mm / inch) Order Code BFS-10-N-AIR Brass BFS-10-O-AIR Brass 0710-007 BFS-10-N-G1/4-MS-NO-ST 0710-001 BFS-10-O-G1/4-MS-NO-ST 0710-019 BFS-10-N-G1/4-MS-WE-ST 0710-013 BFS-10-O-G1/4-MS-WE-ST 0710-008 BFS-10-N-G1/2-MS-NO-ST 0710-002 BFS-10-O-G1/2-MS-NO-ST 0710-020 BFS-10-N-G1/2-MS-WE-ST 0710-014 BFS-10-O-G1/2-MS-WE-ST 0710-009 BFS-10-N-G1-MS-NO-ST 0710-003 BFS-10-O-G1-MS-NO-ST 0710-021 BFS-10-N-G1-MS-WE-ST 0710-015 BFS-10-O-G1-MS-WE-ST Stainless Steel Stainless Steel 0710-010 BFS-10-N-G1/4-SS-NO-ST 0710-004 BFS-10-O-G1/4-SS-NO-ST 0710-022 BFS-10-N-G1/4-SS-WE-ST 0710-016 BFS-10-O-G1/4-SS-WE-ST 0710-011 BFS-10-N-G1/2-SS-NO-ST 0710-005 BFS-10-O-G1/2-SS-NO-ST 0710-023 BFS-10-N-G1/2-SS-WE-ST 0710-017 BFS-10-O-G1/2-SS-WE-ST 0710-012 BFS-10-N-G1-SS-NO-ST 0710-006 BFS-10-O-G1-SS-NO-ST 0710-024 BFS-10-N-G1-SS-WE-ST 0710-018 BFS-10-O-G1-SS-WE-ST Order number example: Order number + switching range = 0710-012, 60 180 l/min Description NO = normally open O = with indication MS = Please specify switching range (see table on page WE = change-over N = without indication SS = stainless steel previous) additional to order number. 2 Subject to technical changes. Barksdale