Ultronics ZTS16 Twin Spool Valve

Similar documents
CMA200 Advanced Subject Independent-Metering title Mobile Valve. 200LPM 440 bar CAN Bus

CMA90 Advanced Independent-Metering Mobile Valve

Mobile Valves Proportional - Load Sensing

XCEL80 Steering Control Units

Eaton. Revised April, Directional Control Valves. Model 30540, 15 GPM Directional Control Valves. We Manufacture. Solutions

Sepehr Hydraulic Asia

Solutions. We Manufacture. H y d r a u l i c s. Eaton Medium Duty Piston Pump. h y d r a u l i c s

MDG Mobile Directional Valve Build Kit. MDG for Mobile Equipment Flows to 60 I/min (15.8 US gpm)

Char-Lynn HP 30 Motor

Char-Lynn Power Steering. Parts Information. 110, 230, and 450 Series. July, 1999

Fixed Displacement Swing Drive Motor. JMF Axial Piston Motor Peak Pressure: 385 bar Displacement 29~250 cc/r

Char-Lynn Power Steering. Parts Information. 217 Series and 227 Series OUT OUT. November, Series (Gerotor Unit) 227 Series (Geroler Unit)

Eaton CMA90 Advanced Sectional Mobile Valves. Technical Catalog

Eaton Inline Self-Level Valve

Mobile Directional Valve. Product Catalog MDG for Mobile Equipment Flows to 60 I/min (15.8 USgpm)

Eaton Heavy Duty Hydrostatic Transmissions

Eaton CMA200 Advanced Sectional Mobile Valves. Technical Catalog

CLS100 Proportional Load Sensing Mobile Valve

Solenoid Operated Directional Valve

Catalog HY /US SERIES CAVITY DESCRIPTION FLOW PRESSURE PAGE NO. LPM/GPM BAR/PSI

A better solution for your toughest light-duty motor challenges.

Superior performance and reliability. Eaton Xcel Series Low-Speed High-Torque Motors

CONTROL SOLUTIONS FORKLIFT TRUCKS FORKLIFT TRUCKS

Mobile Valves Proportional - Load Sensing Model CLS100

CLS180 Proportional Load Sensing Mobile Valve

LOAD SENSE SECTIONS. Series 20. Directional Control Valves NEED NEW PIC VALVES STANDARD FEATURES SPECIFICATIONS

Char-Lynn Steering Control Unit. Repair Information

Eaton Contamination Control Products FT1455-L4 Bench mount launcher operating instructions

Catalog HY /US SERIES CAVITY DESCRIPTION FLOW PRESSURE PAGE NO. LPM/GPM BAR/PSI

Char-Lynn Hydraulic Motor. Parts Information. R Series General Purpose Geroler Motor January, 1995

How to Identify Fluid Ports and Connectors

Contents. Directional Control Valve 2 Series EPCV 452. Page 3. General Information. Page 4-5. Technical data. Page 6. Performance Curves.

Eaton Contamination Control Products FT1455-L3 Hand held launcher operating instructions

Eaton. Revised June, Heavy Duty Hydrostatic Transmissions. l r. Models 33 through 76 Hydrostatic Transmissions. We Manufacture.

Eaton Contamination Control Products FT1455-L2 Hand Held Launcher Operating Instructions

Weatherhead ET4020 & ET4040 Crimp Machines. New Crimp Machines Now Available!

Global Gear Products. Brochure. SAE A-Aluminum (Group 2)

Vickers Counterbalance Valve. CB Series Mainfold Mounting 315 Bar SAE Flange Mounting L/min Subplate Mounting

Large Electronically Adjustable Proportional Pressure Compensated Flow Control Engineering & Manufacturing Solutions

Eaton Electronic Proportional (EP) Control for Medium Duty Piston Pumps

Series PVP Variable Volume Piston Pumps

VIS (Valve-In-Star) Hydraulic Motor

MONOBLOCK DIRECTIONAL CONTROL VALVES

EFC. Electronically Adjustable Proportional Pressure Compensated Flow Control

FT1455-L2 Hand Launcher Operating Instructions

Directional Control Valve Equipment for Front End Loaders

Eaton CLS350 Load Sense Sectional Mobile Valves. Technical Catalog

VT modular. Modular System for LSC Manifold Valve Plates

Flow sharing control block in mono block / sandwich plate design M6-15

Catalog HY /NA. Catalog HY /NA. Parker Hannifin Corporation Hydraulic Pump Division Marysville, Ohio USA

FT1455-L3 Hand Launcher Operating Instructions

BW0511FP. ByWire Elements BW0511FP Flow Sharing Element Interface IBW0511

Displacements cm 3 /r [in 3 /r] Design code [21.0] 400 [24.4] 434 [26.5] 480 [29.3] 677 [41.3] HP30 Motor

Contents. Directional Control Valve 3 Series CV 452. Page 3-4. General Information. Page 5. Technical data. Page 6. Performance Curves.

Section 6.1. Implement Circuit - General System. General: TF Configuration TB Configurations Implement Control Valve:

CANBUS G. Up to mm ( in.) < ± 0.01% of full stroke or ± 0.04 mm ( in.), whichever is greater*

s Eaton Light Duty Hydrostatic h y Hydrostatic Transmissions Models 6, 7, and 11 Ball Piston Pumps Models 7 and 11 We Manufacture Solutions

Eaton Hydrostatic Transaxle. Parts Information. Transaxle Series 751. May, 1999

Electronic Proportional (EP) Control for Heavy Duty Series 2 Piston Pumps Model 33

220 Piston pump Service manual AEC 028

NV452 Monoblock directional control valve

Directional Control Valve CV550

3-Way heavy duty flow control, with pressure compensated, solenoid and load sensing controlled priority flow

Sectional Directional Control Valve RS 220

Electronic Proportional (EP) Control for Heavy Duty Series 0/1 Piston Pumps Model 33 Model 39 Model 46. Model 54 Model 64 Model 76

Eaton Hydraulic Motor. Repair Information. 30 Series. July, 1996

3PC Directional Control Valves

Available manual, pneumatic, and hydraulic spool control kits.

XCEL 45 Steering Control Units

Post-Compensated Proportional Valve CV2000LS

Contents. Directional Control Valve 2 Series CV Unibody. Page 3-4. General Information. Page 5. Technical data. Page 6. Performance Curves

ANTI-SHOCK DIRECTIONAL CONTROL VALVES

Proportional Valves. Proportional solenoid valves for pressure and flow control

Solutions. ydraulics. We Manufacture. H y d r a u l i c s. Eaton Directional Control Valves. h y d r a u l i c s. Models and 31930

Pressure Gauge Kit and Test Couplings

Contents. Directional Control Valve 2 Series CV 300

36EFC. Series & EFC Valve Package

Eaton Hydraulic Motor. Repair Information. VIS 45 Series Two Speed Bearingless -001

Eaton EC inch 6-spiral hose

Electronic Proportional (EP) Control for Medium Duty Piston Pumps

4/3-4/2 Proportional directional valves L5080 solenoid (LC04P) operated (for open loop control) L5080 (LC04P)

Solutions. ydraulics. We Manufacture. H y d r a u l i c s. Eaton. h y d r a u l i c s. Model 30540, 15 GPM Directional Control Valves

Vickers. Proportional Valves. EPV16 Series Valvistor Proportional Flow Controls

Monoblock Directional Control Valve PMB22TSTSAB PMB23TSTSTSLB PMB21TDLB

Sectional Directional Control Valve RSQ 240

Solutions. ydraulics. Manufacture. H y d r a u l i c s. Eaton Hydrostatic Transaxles. h y d r a u l i c s

3-Way heavy duty flow control, with pressure compensated and solenoid controlled priority flow

Pilot-Operated Proportional DC Valve Series D*1FH

4/3 and 4/2 Proportional directional valve elements L8581 with flow (EDC-P1) sharing control (LUDV concept) PATENT PENDING

Series 1 Model Codes

Eaton Hydraulic Motor. Repair Information. 45 Series. July, 1996

Open Center Compact Valve Custom Installation Guide Rev A

4/3 and 4/2 on-off directional valve elements L8511 with flow (EDC-DZ) sharing control (LUDV concept) L8511 (EDC-DZ)

Check valves Direct and pilot operated check valve functions for applications up to 350 bar (5000 psi) and 227 L/min (60 USgpm)

Contents. Quality Hydraulic Components from the Webtec Range. Introduction. Hydraulic Flow Control Valves

4/3 and 4/2 Proportional directional valve elements L8580 with flow (EDC-P) sharing control (LUDV concept) PATENT PENDING

Solenoid Operated Directional Valve

P.C. Priority Flow Control Valve Series J02D3. General Description

Solutions. Hydraulics. We Manufacture. H y d r a u l i c s. Eaton. h y d r a u l i c s. Models and with Pilot Operated Checks

LogSplitterPlans.Com

Transcription:

Ultronics ZTS16 Twin Spool Valve 130 LPM 350 Bar Electronic Load Sense CAN Bus

Table of Contents General Information...3 Specifications...4 Model Code...6 Principles of Operation...8 Performance Data...9 Inlet Options...10 Flow Share Methods...11 Electrical...12 System Layout...13 Work Port Valves...14 Manual Override...15 Interbank Connection Cables...16 Installation Drawings...17 2 EATON Ultronics ZTS16 Technical Catalog E-VLMB-MC001-E3 January 2010

General Information Product Overview The new Ultronics ZTS16 (referred to herein as Ultronics) electronic load sense control valve delivers high performance and reliable valve control during high demand, multifunctioning operational environments. This is possible via: Patented twin spool design Integrated pressure and position sensors On-board electronics & data processing Open architecture 130 LPM (35 gpm) flow rating 350 bar max pressure rating CANbus interface (J1939 or CANopen) With its open architecture and CAN interface, Ultronics has the ability to be a complete Eaton control system* or simply a stand-alone valve solution in a nearly-infinite array of applications for customers and end-users. *Systems offerings may include Eaton EFX controllers Eaton ControlF(x) software Ultronics Joysticks Features and Benefits Configurable Performance Configurable valve parameters allow for rapid and broad changes in valve performance, which reduces system development time, improves productivity without hardware changes. Precise Control A patented independent twin spool design allows precise control of meter-in and meter-out flow under varying load conditions. This reduces inefficiencies and performance compromises with traditional single spool designs. Real-Time Diagnostics and Monitoring Integrated sensors and configuration software enables real-time diagnostics and performance monitoring. Thus, system developers can quickly and efficiently trouble-shoot and commission new systems. Unique Applications Functionality Ultronics open architecture allows users to develop their own application level programs using Eaton s Control F(x) software and EFX controllers, or by using their own controller and associated software. This facilitates advanced system functionality and flexibility. EATON Ultronics ZTS16 Technical Catalog E-VLMB-MC001-E3 January 2010 3

Specifications Pressure Inlet (max)* Work port (max)* Tank** 350 bar (5100 psi) 350 bar (5100 psi) Min. 2 bar (30 psi), Max. 30 bar (435 psi) Flow Inlet (max) Work port (max) 200 lpm (53 gpm) 130 lpm (34 gpm) Temperature Ambient (operating) -40 C to 105 C Oil (operating) -20 C to 85 C Storage -40 C to 120 C Filtration ISO 4406 18/16/13 Electrical Input Voltage 9 32 VDC CAN Interface J1939 2.0B CAN Open Electromagnetic Conducted Emissions CISPR 25: 2002 Radiated Emissions CISPR 25: 2002 Transient Emissions ISO 7637-2: 2004 Radiated Immunity ISO 11452, CISPR 25: 2002, 2004/104/EC Electrostatic Discharge ISO 10605 and SAE J1113-13 Power Frequency Magnet Field Immunity EN 61000-4-8 Reverse Supply Protection -36V Transients Immunity ISO 7637-2:2004 Environmental Ingress Protection IP67 *Note: Valve tested at 350 bar for 1 million cycles per NFPA T 2.6.1. Rated pressure per T 2.6.1. is 300 bar (4350 psi). **Note: With manual override, tank is limited to 10 bar (145 psi) maximum. 4 EATON Ultronics ZTS16 Technical Catalog E-VLMB-MC001-E3 January 2010

Specifications Viscosity Recommended Viscosity 85 to 10 cst 85 to 10 mm 2 /s Absolute Maximum Viscosity 2250 cst 2250 mm 2 /s Absolute Minimum Viscosity 7 cst 7 mm 2 /s Leakage Max Leakage* * Data taken from work port to tank 23 cc @ 100 Bar @ 23 cst EATON Ultronics ZTS16 Technical Catalog E-VLMB-MC001-E3 January 2010 5

Model Code Note: Model code represents single valve bank. Multiple valve bank systems will have multiple model codes. ZTS 16 * * * * C * * *** *** * ** ** ** *** ** ** *** ** 00 *** 10 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 1 Valve Series 5 CAN Bus Terminator 8 Main Ports 10 Inlet Pressure Controller ZTS Ultronics ZTS16 2 Spool 16 Size 3 Communication Interface J J1939 CAN 2.0B O CAN-Open 4 Interface Module M VSM - Valve System Module. One required per system located on first valve bank in system E VSE - Valve System Extender. Required when valve bank is greater than 4 meters from previous valve bank in system 0 None - When valve is less than 4 meters from a VSM or VSE valve bank and daisy chain is desired Note: if 0 is chosen, an interconnection cable must be ordered separately. See note below for part numbers. Note: Maximum of 2 VSE allowed per system. T One Section 0 No CAN bus terminator - true when valve bank is the start of, or within, a daisy chain 6 Number of Sections in Valve Bank 1 One Section 2 Two Sections 3 Three Sections 4 Four Sections 5 Five Sections 6 Six Sections 7 Bank Type C Standard valve bank S Supply Ports: 1-1/16-12UN (SAE-12), Tank Port: 1-5/16-12UN (SAE-16), LS Port: 7/16-18UNF (SAE-4) B Supply Ports: G3/4, Tank Port: G1, LS Port G1/4 Note: LS port will not be included when fixed displacement inlet controller is selected. 9 Active Pressure Ports 1 P1 2 P2 3 P3 4 P1 & P2 5 P1 & P3 6 P2 & P3 7 P1, P2 & P3 Note: Selections with P1 port are preferred as primary pressure port but other options may be used depending on system layout. Note: All active ports will be capped with plastic shipping plugs. FDP Used with fixed displacement pump LSP Used with variable displacement load sense pump FDM Used with fixed displacement pump when manual override option L1 or L2 is selected. Not required with S1, S2 or S3 manual options. See model code position 19. LSM Used with variable displacement load sense pump when manual override option L1 or L2 is selected. Not required with S1, S2 or S3 manual options. See model code position 19. 000 None - Used when interface module code is E or 0 6 EATON Ultronics ZTS16 Technical Catalog E-VLMB-MC001-E3 January 2010

Model Code Note: Model code represents single valve bank. Multiple valve bank systems will have multiple model codes. ZTS 16 * * * * C * * *** *** * ** ** ** *** ** ** *** ** 00 *** 10 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 11 Main Relief 000 None 050 50 bar 350 350 bar Note: The main relief is intended as a system relief. Relief setting available in increments of 10 bar. Note: Position codes for 12 through 20 will repeat for each section. 12 Section See drawing for work port labels A Section B Section C Section D Section E Section F Section 13 Thread Type J3 3/4-16 UNF (SAE-8) J4 7/8-14 UNF (SAE-10) J5 1-1/16-12UN (SAE-12) F3 G3/8 F4 G1/2 F5 G3/4 Note: J Threads meet SAE J1926/ISO 11926 standards; F Threads meet DIN 3852 Pt 2 standards. 14 Spool 1 Type HC 130 lpm, biased to center HT 130 lpm, biased to tank HP 130 lpm, biased to pressure 15 Work Port Valves - Side 1 00 None AS Anti-Cav Valve with shock valve AC Anti-Cav Valve SV Shock Valve A1 B1 C1 D1 E1 F1 16 Shock Valve Setting - Side 1 000 None 050 50 bar 350 350 bar Note: Available in increments of 10 bar, between 50 and 350 bar. 17 Spool 2 Type HC 130 lpm, biased to center HT 130 lpm, biased to tank HP 130 lpm, biased to pressure 18 Work Port Valves - Side 2 00 None AS Anti-Cav Valve with shock valve AC Anti-Cav Valve 19 Shock Valve Setting - Side 2 000 None 050 50 bar 350 350 bar Note: Available in increments of 10 bar, between 50 and 350 bar. 20 Manual Override 00 None L1 Lever-handle position from direction 1 L2 Lever-handle position from direction 2 S1 Single spool override - pos.1 S2 Single spool override - pos. 2 S3 Single spool override - pos.1 & pos. 2 Note: Manual override is not an alternative mode of manual actuation. 21 Special Features 00 None 22 Software Version XXX Software version will be automatically populated P3 P1 23 Design Code 10 This section left blank intentionally T A2 B2 C2 D2 E2 F2 P2 LS EATON Ultronics ZTS16 Technical Catalog E-VLMB-MC001-E3 January 2010 7

Principles of Operation Valve Cross Section Section Schematic 1. Main stage monoblock casting 2. Mainstage spools 3. Pilot valve 4. Voice coil actuator 5. Centering spring 6. Pilot spools 7. Position sensor 8. Pressure sensor 9. On-board electronics 3 2 9 6 4 5 8 Not directly illustrated. Thin film pressure sensor located in each work port position at split line 7 2 Work Section The work section is comprised of two independent spools(2) that act as a pair working to control double acting services, or alternatively as single spools controlling a singe acting service (2 single axis services can be controlled from any work section). Demands to each work section are transmitted over a CAN Bus and power is provided to each work section via a single daisy chain cable arrangement. Each work section has a single pilot valve comprised of on-board electronics (9), two independent 3 position 4 way pilot spools driven by low power bi-directional voice coil actuators(4), and embedded sensors. The independent pilot spools control the mainstage spools. Closed loop control of each work section is done locally by leveraging the on-board electronics and sensors. Each mainstage spool has its own LVDT position sensor (7) enabling closed loop position control of the mainstage spool. Further, a thin film pressure sensor (8) is located in each work port, pressure line and tank line. By knowing spool position and pressure drop across the orifice created by the mainstage spool, it is possible to calculate flow and thereby control flow per the equation to the right. Supply Tank Pilot Pressure Tank Supply Pilot Pressure To Service Q = Flow rate Cd = Discharge Coefficient A = Area ρ = Density ΔP = Pressure Drop PT LVDT 2 Q=Cd (x, temp) *A* * ΔP ρ (temp) To Service PT LVDT Note: the equation is above is representative only and does not represent exact control algorthim. 8 EATON Ultronics ZTS16 Technical Catalog E-VLMB-MC001-E3 January 2010

Performance Data Inlet to Work Port Work Port to Tank Differential Pressure - BAR (PSI) 12.00 (174) 10.00 (145) 8.00 (116) 6.00 (87) 4.00 (58) 2.00 (29) Section A Section F Differential Pressure - BAR (PSI) 5.00 (73) 4.00 (58) 3.00 (43) 2.00 (29) 1.00 (14) Section A Section F 0.00 0 20 (5.3) 40 (10.6) 60 (15.9) 80 (21.1) Flow - LPM (GPM) 100 (26.4) 120 (31.7) 140 (37.0) 0.00 0 20 (5.3) 40 60 80 (10.6) (15.9) (21.1) Flow - LPM (GPM) 100 (26.4) 120 (31.7) 140 (37.0) Inlet Pressure Relief Override Curves Unloader Pressure Drop Curve Differential Pressure - BAR (PSI) 400 (5800) 300 (4300) 200 (2900) 100 (1450) 320 Bar 300 Bar 250 Bar 200 Bar 120 Bar Inlet-Tank - BAR (PSI) 25 (363) 20 (290) 15 (218) 10 (145) 5 (73) 0 0 20 (5.3) 40 (10.6) 60 (15.9) 80 (21.1) 100 (26.4) Flow - LPM (GPM) 120 (31.7) 140 (37.0) 160 (42.2) 0 0 50 (13.2) 100 150 (26.4) (39.6) Flow - LPM (GPM) 200 (52.9) 250 (66.0) EATON Ultronics ZTS16 Technical Catalog E-VLMB-MC001-E3 January 2010 9

Inlet Options Ultronics ZTS16 valve can be used with both fixed and variable displacement pumps. Fixed Displacement Inlet Fixed displacement inlet schematic The fixed displacement inlet consists of a pilot valve that pilots a primary unloading spool. Based on the electronically demanded system pressure requirement, the primary spool either closes to restrict supply and thus build system pressure or opens to allow flow to freely flow back to tank. A mechanical main system relief is included to provided for over pressure protection. Tank Supply Supply Tank Pilot Pressure PT PT LVDT Variable Displacement Inlet Variable displacement inlet schematic Like the fixed displacement inlet, the variable displacement inlet consists of a primary spool controlled by a high performance pilot valve. The pilot valve provides pilot pressure to either side of the primary spool which meters supply flow, based on the electronic load-sense demand, to create the hydraulic load sense signal necessary actuate the pump compensator and ultimately the pump swash plate. A main relief is shown here, but not required as maximum system pressure is also controlled by pump compensator. Load Sense Tank Supply Supply Tank Load Sense Pilot Pressure PT PT PT LVDT Load Sense Unlike traditional mobile valves, Ultronics does not have internal load-sense lines and check valves to communicate load pressures. Ultronics determines load sense pressures electronically via its embedded pressure sensors and then communicates them via CAN Bus to the inlet pressure controller which controls system pressure. Since the load sense signal is electronic, load-sense margins for the system or specific valve sections are configurable via software. 10 EATON Ultronics ZTS16 Technical Catalog E-VLMB-MC001-E3 January 2010

Flow Share Methods Flow Share Methods Ultronics has three distinct, software configurable, flow share methods. All control methods are electronically compensated and perform the same until the pump flow is fully consumed (fully saturated). After saturated, the valve will share flow according to one of the software selected methods identified below: Full Flow 160 150 140 130 120 110 100 90 80 70 60 50 40 30 20 10 0 Available Flow Valve Section Section 1 Section 2 Section 3 Section 4 Ratio The Ratio method will reduce all non-priority flow demands by the same relative amount; i.e., the same percentage. This method permits the use of all flow services until the pump flow is fully consumed by priority services. As pump flow decreases, all non-priority Cascading The Cascade method will reduce non-priority flow demands according to a priority rating. Each non-priority flow service is assigned a priority rating. The rating specifies the order in which the flow demands are reduced. This method allows higher priority services to run with their demanded flow unchanged, whilst lower flow demands are reduced by the same percentage and would all reach a demand of zero at the same time. This method is similar to postcompensated, anti-saturation valve systems. priority are reduced. As pump flow decreases, the higher priority flow demands remain unchanged but the lower priority flow demands are reduced. When the lowest priority flow demands hit zero, the next lowest priority demands are reduced. Reduced Flow-Ratio Method 160 150 140 130 120 110 100 90 80 70 60 50 40 30 20 10 0 Available Flow 160 150 140 130 120 110 100 90 80 70 60 50 40 30 20 10 0 Available Flow Valve Section Reduced Flow-Ratio Cascading Method Valve Section Section 1 Section 2 Section 3 Section 4 Section 1 Section 2 Section 3 Section 4 Uniform Reduced Flow-Ratio Uniform Method The Uniform method will reduce all non-priority flow demands by the same actual amount. This method keeps services with higher flow demands operating in preference to services with low flow demands. As pump flow decreases, all non-priority flow demands are reduced by the same numerical value, so all demands are reduced, but lower flow demands reach zero before higher flow demands. 160 150 140 130 120 110 100 90 80 70 60 50 40 30 20 10 0 Available Flow Valve Section Section 1 Section 2 Section 3 Section 4 EATON Ultronics ZTS16 Technical Catalog E-VLMB-MC001-E3 January 2010 11

Electrical Power and control are provided to the Ultronics system through a 14 AMP connector on the Valve System Module (VSM). The VSM acts as a gateway between the vehicle CAN Bus and power and the Ultronics valve system. All valve control signals are transmitted over CAN Bus to the single source address assigned to the valve system. If the total distance of the CAN Bus is less than 4 meters, it is possible to daisy chain the valve banks together using the standard 9-pin Ultronics connector. If the total distance of the CAN Bus is greater than 4 meters, a Valve System Extender (VSE) must be used. Pin No. VSM 14-way Connector Function (Black Connector) 1 Battery + Supply 2 Battery + Supply 3 CAN_SHLD CAN Shield (cable screen) 4 CAN_TRM_A CAN terminate A 5 CAN_H CAN High 6 Battery - Supply Return 7 Battery - Supply Return 8 CAN_TRM_B CAN terminate B 9 CAN_L CAN Low 10 ICOM_HIGH Interconnect COM High 11 ICOM_LOW Interconnect COM Low 12 ICOM_HIGH Interconnect CAN High (pass through) 13 ICOM_LOW Interconnect COM Low (pass through) 14 ICOM_TRM Interconnect COM terminate Pin No. VSE 14-way Connector Function (Grey Connector) 1 Battery + Supply 2 Battery + Supply 3 Block ID A 4 Block ID B 5 Not Connected 6 Battery - Supply Return 7 Battery - Supply Return 8 Not Connected 9 Not Connected 10 ICOM_HIGH Interconnect COM High 11 ICOM_LOW Interconnect COM Low 12 ICOM_HIGH Interconnect CAN High (pass through) 13 ICOM_LOW Interconnect COM Low (pass through) 14 ICOM_TRM Interconnect COM terminate Note This product has been designed and tested to meet the requirements outlined in the EU directives 75/332/EEC and 89/336/EEC as amended by 2000/2/EC and 2004/108/EC respectively. Additionally, the product has been designed to meet the requirements of EU directive 72/245/ EEC as amended by 2004/104/EC. 14-Way Connector 12 EATON Ultronics ZTS16 Technical Catalog E-VLMB-MC001-E3 January 2010

System Layout There are multiple interconnection options for Ultronics valve systems with more than one valve bank. The following figures illustrate possible system configuration options for the Ultronics ZTS16. The configurations are representative only and do not represent all possible configurations. Configuration is dependent on application requirements and is constrained by the following rules: - Maximum of 15 sections per system - Each valve bank can have up to 6 sections - One VSM and corresponding CV required per system - If distance between a extension valve bank and the VSM or VSE is less than 4 meters, they can be connected using a daisy chain extension cable. See Interbank Connection options on page 16. - If distance between valve banks is greater than 4 meters, they must be connected using VSE and external wiring harness. Layout Example: 2 Bank with VSE VSE_1 CV VSM Battery ECU Layout Example: 1 Bank Layout Example: 3 Bank with 2 VSEs CV CV VSM VSE_2 VSE_1 VSM Battery Battery ECU ECU Layout Example: 3 Bank with VSE and Daisy Chain Layout Example: 2 Bank with Daisy Chain L 4 m CV CV VSE_1 4m <L< 30m VSM VSM ECU Battery ECU Battery EATON Ultronics ZTS16 Technical Catalog E-VLMB-MC001-E3 January 2010 13

Work Port Valves The Ultronics ZTS16 has three methods for controlling and limiting maximum port pressures. Pressure Max above this pressure individual port flow will be regulated to limit pressure to this value. Also, the port will not accept a pressure demand above this limit. The Maximum Pressure Control value is set by software. This value should be set to what mechanical port reliefs/ shock valves are set to in a traditional mobile valve. Mechanical Shock Valve mechanical shock valves are optional and provide additional protection for load induced pressure spikes. Software Relief when a load is induced above this value, the work port spool will service to tank. This value, at minimum, should be set +30 bar above mechanical relief or +40 bar above Pressure Max. Ultronics Traditional Valves Ultronics ZTS16 Traditional Valves Typical Typical: 1030 Bar Software Pressure Relief (Software Driven) Typical Typical: 10 10 Bar Bar Mechanical Shock (Hardware Driven) Pressure Max (Software Pressure Driven) Max Mechanical Relief (Hardware Mechanical Driven) Relief Mechanical Work Port Valve Options Anti-cav + Shock Valve (AS) Anti-cav Valve (AC): Work Port Tank Work Port Tank 14 EATON Ultronics ZTS16 Technical Catalog E-VLMB-MC001-E3 January 2010

192.80 Manual Override Lever- Handle Override (L1 = handle on side 1; L2 = handle on side 2) Note: Manual override is not an alternative mode of manual actuation. Pull for two-spool operation 5-7mm This is the minimum clearance required for operation of the manual override levers. Note that levers do not move during normal operation of the valve. 7 7 Operation: Pull handle to engage and operate manual override. Moving the lever up will port fluid from P to P1, and from P2 to tank. Moving lever down will port fluid from P to P2, and from P1 to tank. Single-Spool Override (S1 = side 1; S2 = side 2; S3 = both sides*) * This is possible if each spool is acting as a single service for supply and return (i.e. spring return ram) Operation: A captive hexagon nut on the spindle will drive towards the spool when the spindle is turned. This pushes the spool towards the tank only. If spool is biased to pressure, fluid will be relieved to service port then tank. If spool is biased to center, fluid will be relieved to tank. (If spool is biased to tank, fluid is already relieved to tank). EATON Ultronics ZTS16 Technical Catalog E-VLMB-MC001-E3 January 2010 15

Interbank Connection Cables Interbank Connection Cable Interbank Connection Cables Part Numbers Description 2063-001-200 2.0 meter interconnection cable 2063-001-400 4.0 meter interconnection cable Note: If more than one cable is used in a single daisy chain with multiple valve banks, then the combined lengths must be < = 4m. CAN Bus Terminator Assembly Part Numbers Description 2059-030-00L 120 ohm CAN Bus terminator 14-Way Connector (AMP Plug) Part Numbers Description 9615-091-BKM 9615-092-GKY Black 14-way plug assembly kit (VSM) Grey 14-way plug assembly kit (VSE) 16 EATON Ultronics ZTS16 Technical Catalog E-VLMB-MC001-E3 January 2010

Installation Drawing AMPSEAL 14-WAY CONNECTOR Note: All dimensions are in millimeters. P3 PORT Alternative Supply Port (Supplied Plugged) P2 PORT Alternative Supply Port (Supplied Plugged) 43 27 170,30 - See Notes 18 62,50 27 48,50 PORT A2 PORT B2 PORT C2 PORT D2 PORT E2 PORT F2 PORTS A1 to F1 on other side 458 REF Overall Length - See Table EATON Ultronics ZTS16 Technical Catalog E-VLMB-MC001-E3 January 2010 17

Installation Drawing T PORT Return to tank Note: All dimensions are in millimeters. LOAD SENSE PORT (for variable displacment systems ONLY) 85,5 MAX Without RelieF Valve 89,50 MAX With Relief Valve 114 57 86 MAX 43,50 57,50 P1 PORT Supply Inlet from Pump. Alternative ports P2 or P3 may be used to suit installation. MAIN SYSTEM RELIEF VALVE Pilot Stage 27 43 MAIN SYSTEM RELIEF VALVE Main Stage 0 27 78 REF Dimension F 127 REF Dimension E 176 REF Dimension D 225 REF Dimension C 274 REF Dimension B 323 REF Dimension A 347 REF Mounting Centers See Table 4 MOUNTING HOLES M8 x 22 Deep 48,50 Number of Mounting Overall Dim. Dim. Dim. Dim. Dim. Dim. Valve Sections Centers Length a b c d e f 1 102 213 78 x x x x x 2 151 262 127 78 x x x x 3 200 311 176 127 78 x x x 4 249 360 225 176 127 78 x x 5 298 409 274 225 176 127 78 x 6 347 458 323 274 225 176 127 78 18 EATON Ultronics ZTS16 Technical Catalog E-VLMB-MC001-E3 January 2010

Eaton Hydraulics Group USA 14615 Lone Oak Road Eden Prairie, MN 55344 USA Tel: 952-937-9800 Fax: 952-294-7722 www.eaton.com/hydraulics Eaton Hydraulics Group Europe Route de la Longeraie 7 1110 Morges Switzerland Tel: +41 (0) 21 811 4600 Fax: +41 (0) 21 811 4601 Eaton Hydraulics Group Asia Pacific Eaton Building 4 th Floor, No. 3 Lane 280 Linhong Rd. Changning District Shanghai 200335 China Tel: (+86 21) 5200 0099 Fax: (+86 21) 5200 0400 2010 Eaton Corporation All Rights Reserved Printed in USA Document No. E-VLMB-MC001-E3 Supersedes E-VLMB-MC001-E2 January 2010