Directional valves Electrically operated CL03 series-ev. Brochure

Similar documents
Valve terminal systems Valve terminal systems Series TC15. Brochure

Valve terminal systems Valve terminal systems Series TC08. Brochure

Directional valves Pneumatically operated Series 740. Brochure

Directional valves Mechanically operated Series CD07. Brochure

Directional valves Mechanically operated Series AP. Brochure

Rotary actuators Rack-and-pinion gears series TRR. Brochure

Mounting on manifold strip. Working pressure min./max. Max. particle size 5 µm. Connector standard ISO 15217

Rodless cylinders Bellow actuator Bellow actuator with mounting ring, series BCR. Brochure

Pneumatic connection technologies Rotary joints Rotary joints. Brochure

Cylinder accessories Shock absorbers SA2 series. Brochure

Flow and check valves Logic valves Logic valves (AND/OR) Brochure

Pressure regulators E/P pressure regulators Series EV04. Brochure

SCU Stretching Cylinder Units for PET Blow Molding Machines

Electric Drives. Linear Motion and Assembly Technologies Pneumatics Service. Valves, Series VP15. Technical data

Pressure regulators E/P pressure regulators Series EV07. Brochure

Directional valves Pneumatically operated, according to standard ISO , 18 mm, CD02-AL series. Brochure

5/2 Valve Series 585, G 1/8-G 1/4

Directional valves Mechanically operated Series AP - inch. Brochure

Pressure regulators E/P pressure regulators Series ED05. Brochure

Pressure regulators E/P pressure regulators Series ED02. Brochure

3/2 Dovetail Valves, ND 2, G 1/8

Rodless cylinders Rodless cylinders Series RTC. Brochure

The New Generation ISO Cylinders for a Dynamic Future

5/2-way valve, Series ST Qn= 280 l/min pipe connection compressed air connection output: G 1/8 with spring return

Flow and check valves Logic valves Pneumatic counters. Brochure

Highly Varied and Energy Efficient The CVI Series of Cylinder Valve Units from Rexroth

Берг АБ Тел. (495) , факс (495) ITS Series Pneumatic Cylinders Extreme Resilience and Power

Ejector, Series EBS push-in fitting electrical control, T-design with release valve with silencer

Max. particle size 50 µm

E/P pressure regulator, Series ED07 Qn= 1300 l/min Electr. connection: via signal connection Signal connection: input and output, Plug, M12, 5-pin

Max. particle size 50 µm Max. oil content of compressed air

Sensor technologies Pressure sensors Series PE5. Brochure

Number of fingers 2. Max. particle size 5 µm. Pressure for determining forces

Rodless cylinders Bellow actuator Bellow actuator with mounting ring, series BCR. Brochure

6/2 ways/positions flow diverters

6/2 ways/positions flow diverters L (VS151-VS152-VS155)

3/2 ways/positions flow diverters L (VS91-VS92-VS95)

Ejector, Series EBS Thread connection pneumatic control, T-design with silencer

Preparation of compressed air Supplementary products Pressure gauge. Brochure

6/2 ways/positions flow diverters L (VS120-VS125-VS129)

Max. oil content of compressed air

4/2 servo solenoid valves with positive overlap and position feedback (Lvdt AC/AC)

6/2 ways/positions flow diverters

6 to14/2 ways/positions bankable flow diverters flangeable

4/3-4/2 Directional valve elements LF1_1 (LC1F-Z)

Cylinder Accessories Piston rod mountings, series CM2 Rod clevises. Brochure

6 to 12/2 ways/positions bankable flow diverters flangeable

6/2 ways/positions flow diverters

3/2 ways/positions flow diverters

4/3-4/2 Directional valve with solenoid actuation

6 to14/2 ways/positions bankable flow diverters flangeable

Stand alone 4/3, 4/2 solenoid operated directional valve

6 to14/2 ways/positions bankable flow diverters flangeable

Series PD directly operated solenoid valves

4/3-4/2 Directional valve elements with or without secondary relief valves, and with or without LS connections

Breather filter. RE 51414/02.09 Replaces: Types BF 7 SL ; BS 7 SL ; BE 7 SL ; B 7 SL

ES05 THE ESSENTIAL valve SYSTEM

6 to 12/2 ways/positions bankable flow diverters flangeable

Stand alone 4/3, 4/2 direct acting directional valve LF2_1 (LC2F-DZ)

4/3-4/2 Directional valve elements B8_0A with or without (EDB-A) secondary relief valves, with or without LS connections B8_0A (EDB-A)

Electronic pressure switch with two switching outputs

Sensor technologies Proximity sensors Sensor mountings. Brochure

Proportional pressure reducing valve, pilot operated

4/2 servo solenoid valves with on-board electronics (OBE), positive overlap and position feedback

Electronic pressure switch with integrated analogue output

4/2 and 4/3-Way Proportional Directional Control Valve Direct Operated

Electrically operated spool valve. The manual override is detent and is operated by screw driver.

Mating connectors for controlling electrically operated valves and sensors

4/3 4/2 Directional valve elements with or without secondary relief valves, and with or without LS connections

Directional valve elements L808103P (ED4-PT1) of Tank unloaded excess flow. RE Edition: Replaces:

4/3, 4/2 proportional directional valves solenoid operated (for open loop control)

Servo solenoid valves with on-board electronics (OBE)

Series PD directly operated solenoid valves

4/3-4/2 Proportional directional valves L5080 solenoid (LC04P) operated (for open loop control) L5080 (LC04P)

Check valve. RE 21536/07.05 Replaces: Type Z1S. Size10 Component series 3X Maximum operating pressure 315 bar Maximum flow 100 l/min 1/6

Pressure reducing valve, direct operated

Proportional pressure reducing valve, pilot operated

3/2-way Solenoid Valve for pneumatics

Series RE-10. Valve terminals > Technical details. Order code RE-10/**-***-*** Temperature range Medium +5 C C

Series MI-01, MI-02, MI-03

Series RE-46. Valve terminals > Technical details. Order code RE-46/**-*-***-*** Temperature range Medium -10 C C

Directional servo-valve of 4-way design

Proportional cartridge throttle valve, with inductive position transducer, pilot operated

3/2 and 4/2 directional seat valves with solenoid actuation

3/2 and 4/2 directional seat valves with solenoid actuation

Cylinder Accessories Handling connection kits Easy2Combine. Brochure

4/3 and 4/2 on-off directional valve elements L8511 with flow (EDC-DZ) sharing control (LUDV concept) L8511 (EDC-DZ)

4/3 and 4/2 Proportional directional valve elements L8580 with flow (EDC-P) sharing control (LUDV concept) PATENT PENDING

Nominal sizes 08 to 10, special cavities

4/3 and 4/2 Proportional directional valve elements L8581 with flow (EDC-P1) sharing control (LUDV concept) PATENT PENDING

3/2 directional spool valve, direct operated with solenoid actuation

Cylinder Accessories Cylinder mountings; series CM1 Trunnion mountings. Brochure

Proportional pressure relief valve

Servo solenoid valves with positive overlap and on-board electronics (OBE)

On/off valves with spool position monitoring

Proportional pressure reducing valve, pilot operated

Proportional cartridge throttle valve, with on-board electronics (OBE) and inductive position transducer, pilot operated

Proportional pressure relief valve, pilot operated

4/3 Proportional directional valve elements L85P5 with proportional (EDC-IP) hydraulic control and flow sharing control (LUDV concept) PATENT PENDING

3/2 and 4/2 directional seat valves with solenoid actuation

Transcription:

CL03 series-ev Brochure

2 Rexroth Pneumatics CL03 series-ev Qn = 700 l/min valve width: 16 mm NO/NC plate connection compressed air connection output: Ø 8 - G 1/8 Manual override: detent 3 Qn = 700 l/min valve width: 16 mm NO/NO plate connection compressed air connection output: Ø 8 - G 1/8 Manual override: detent 6 Qn = 700 l/min valve width: 16 mm NC/NC plate connection compressed air connection output: Ø 8 - G 1/8 Manual override: detent 9 5/2-directional valve, Series CL03-EV Qn = 700 l/min valve width: 16 mm plate connection compressed air connection output: Ø 8 - G 1/8 Manual override: detent single solenoid 12 5/2-directional valve, Series CL03-EV Qn = 700 l/min valve width: 16 mm plate connection compressed air connection output: Ø 8 - G 1/8 Manual override: detent double solenoid 15 5/3-directional valve, Series CL03-EV Qn = 700 l/min valve width: 16 mm plate connection compressed air connection output: Ø 8 - G 1/8 Manual override: detent 18 Zubehör Connecting cable plug and socket Socket, M12x1, 4-pin, A-coded Plug, M12x1, 4-pin, A-coded 21

Rexroth Pneumatics 3 Qn = 700 l/min valve width: 16 mm NO/NC plate connection compressed air connection output: Ø 8 - G 1/8 Manual override: detent 21013 Version Spool valve, zero overlap External Sealing principle Soft sealing Blocking principle Single base plate principle Working pressure min./max. -0.9 bar / 10 bar Control pressure 2.5 bar / 10 bar min./max. Ambient temperature min./max. Medium temperature min./max. Medium Compressed air Max. particle size 40 µm Oil content of compressed air 10 mg/m³ With collective pilot air exhaust Degree of protection electrical connector/plug Protective circuit Status display LED IP 65, IP 67, IP 69K Duty cycle 100 % Switch-on time 16 ms Switch-off time 25 ms Generic emission standard in accordance EN 61000-6-4 Generic immunity standard in accordance EN 61000-6-2 Mounting screw M5 mounting screw tightening torque 2 Nm Tightening torque tolerance ±0,2 Weight 0.165 kg Z-diode Protected against polarity reversal Yellow Materials: Housing Seals Polyamide, fiber-glass reinforced Hydrogenated acrylonitrile butadiene rubber Technical Remarks The pressure dew point must be at least 15 C under ambient and medium temperature and may not exceed 3 C. The oil content of compressed air must remain constant during the life cycle. Use only the approved oils from Rexroth Pneumatics, see chapter Technical information. The pilot valve is UL (Underwriters Laboratories) certified. For series QR2 fittings, see Pneumatic connection technologies. The inner valve can be replaced by all series CL03 valves described under Valve systems. Operating Voltage tolerance Power consumption DC DC DC W 24 V -15% / +20% 0.35

4 Rexroth Pneumatics Qn = 700 l/min valve width: 16 mm NO/NC plate connection compressed air connection output: Ø 8 - G 1/8 Manual override: detent NO/ NC MO Compressed air connection Operating Input Output Exhaust connection control exhaust Flow conductance DC b C Part No. [l/(s*bar)] Ø 8 Ø 8 Ø 8 Ø 4 Ø 4 R412017959 Ø 8 Ø 8 Ø 8 Ø 4 Ø 4 24 V 0.22 2.9 R412017960 G 1/8 G 1/8 G 1/8 M5 M5 R412017961 Part No. Flow rate value Note Qn [l/min] R412017959 1) R412017960 700 2) R412017961 - HHB = Manual override 1) push-in fitting: Brass, nickel-plated 2) push-in fitting: Stainless steel Nominal flow Qn at 6 bar and Δp = 1 bar

Rexroth Pneumatics 5 Qn = 700 l/min valve width: 16 mm NO/NC plate connection compressed air connection output: Ø 8 - G 1/8 Manual override: detent Dimensions 50 110 23,6 12 32,5 69,4 34,6 170 4 1 3 168,2 189 45 2 Electrical connection: 1) Not connected 2) Solenoid 12 3) Ground 4) Solenoid 14 20458

6 Rexroth Pneumatics Qn = 700 l/min valve width: 16 mm NO/NO plate connection compressed air connection output: Ø 8 - G 1/8 Manual override: detent 21013 Certificates UR (Underwriters Laboratories) Version Spool valve, zero overlap External Sealing principle Soft sealing Blocking principle Single base plate principle Working pressure min./max. -0.9 bar / 10 bar Control pressure 2.5 bar / 10 bar min./max. Ambient temperature min./max. Medium temperature min./max. Medium Compressed air Max. particle size 40 µm Oil content of compressed air 10 mg/m³ With collective pilot air exhaust Degree of protection electrical connector/plug Protective circuit Status display LED IP 65, IP 67, IP 69K Duty cycle 100 % Switch-on time 16 ms Switch-off time 25 ms Generic emission standard in accordance EN 61000-6-4 Generic immunity standard in accordance EN 61000-6-2 Mounting screw M5 mounting screw tightening torque 2 Nm Tightening torque tolerance ±0,2 Weight 0.165 kg Z-diode Protected against polarity reversal Yellow Materials: Housing Seals Polyamide, fiber-glass reinforced Hydrogenated acrylonitrile butadiene rubber Technical Remarks The pressure dew point must be at least 15 C under ambient and medium temperature and may not exceed 3 C. The oil content of compressed air must remain constant during the life cycle. Use only the approved oils from Rexroth Pneumatics, see chapter Technical information. The pilot valve is UL (Underwriters Laboratories) certified. For series QR2 fittings, see Pneumatic connection technologies. The inner valve can be replaced by all series CL03 valves described under Valve systems. Operating Voltage tolerance Power consumption DC DC DC W 24 V -15% / +20% 0.35

Rexroth Pneumatics 7 Qn = 700 l/min valve width: 16 mm NO/NO plate connection compressed air connection output: Ø 8 - G 1/8 Manual override: detent NO/ NO MO Compressed air connection Operating Input Output Exhaust connection control exhaust Flow conductance DC b C Part No. [l/(s*bar)] Ø 8 Ø 8 Ø 8 Ø 4 Ø 4 R412017956 Ø 8 Ø 8 Ø 8 Ø 4 Ø 4 24 V 0.22 2.9 R412017957 G 1/8 G 1/8 G 1/8 M5 M5 R412017958 Part No. Flow rate value Note Qn [l/min] R412017956 1) R412017957 700 2) R412017958 - HHB = Manual override 1) push-in fitting: Brass, nickel-plated 2) push-in fitting: Stainless steel Nominal flow Qn at 6 bar and Δp = 1 bar

8 Rexroth Pneumatics Qn = 700 l/min valve width: 16 mm NO/NO plate connection compressed air connection output: Ø 8 - G 1/8 Manual override: detent Dimensions 50 110 23,6 12 32,5 69,4 34,6 170 4 1 3 168,2 189 45 2 Electrical connection: 1) Not connected 2) Solenoid 12 3) Ground 4) Solenoid 14 20458

Rexroth Pneumatics 9 Qn = 700 l/min valve width: 16 mm NC/NC plate connection compressed air connection output: Ø 8 - G 1/8 Manual override: detent 21013 Version Spool valve, zero overlap External Sealing principle Soft sealing Blocking principle Single base plate principle Working pressure min./max. -0.9 bar / 10 bar Control pressure 2.5 bar / 10 bar min./max. Ambient temperature min./max. Medium temperature min./max. Medium Compressed air Max. particle size 40 µm Oil content of compressed air 10 mg/m³ With collective pilot air exhaust Degree of protection electrical connector/plug Protective circuit Status display LED IP 65, IP 67, IP 69K Duty cycle 100 % Switch-on time 16 ms Switch-off time 25 ms Generic emission standard in accordance EN 61000-6-4 Generic immunity standard in accordance EN 61000-6-2 Mounting screw M5 mounting screw tightening torque 2 Nm Tightening torque tolerance ±0,2 Weight 0.165 kg Z-diode Protected against polarity reversal Yellow Materials: Housing Seals Polyamide, fiber-glass reinforced Hydrogenated acrylonitrile butadiene rubber Technical Remarks The pressure dew point must be at least 15 C under ambient and medium temperature and may not exceed 3 C. The oil content of compressed air must remain constant during the life cycle. Use only the approved oils from Rexroth Pneumatics, see chapter Technical information. The pilot valve is UL (Underwriters Laboratories) certified. For series QR2 fittings, see Pneumatic connection technologies. The inner valve can be replaced by all series CL03 valves described under Valve systems. Operating Voltage tolerance Power consumption DC DC DC W 24 V -15% / +20% 0.35

10 Rexroth Pneumatics Qn = 700 l/min valve width: 16 mm NC/NC plate connection compressed air connection output: Ø 8 - G 1/8 Manual override: detent NC/ NC MO Compressed air connection Operating Input Output Exhaust connection control exhaust Flow conductance DC b C Part No. [l/(s*bar)] Ø 8 Ø 8 Ø 8 Ø 4 Ø 4 R412021814 Ø 8 Ø 8 Ø 8 Ø 4 Ø 4 24 V 0.22 2.9 R412021815 G 1/8 G 1/8 G 1/8 M5 M5 R412021816 Part No. Flow rate value Note Qn [l/min] R412021814 1) R412021815 700 2) R412021816 - HHB = Manual override 1) push-in fitting: Brass, nickel-plated 2) push-in fitting: Stainless steel Nominal flow Qn at 6 bar and Δp = 1 bar

Rexroth Pneumatics 11 Qn = 700 l/min valve width: 16 mm NC/NC plate connection compressed air connection output: Ø 8 - G 1/8 Manual override: detent Dimensions 50 110 23,6 12 32,5 69,4 34,6 170 4 1 3 168,2 189 45 2 Electrical connection: 1) Not connected 2) Solenoid 12 3) Ground 4) Solenoid 14 20458

12 Rexroth Pneumatics 5/2-directional valve, Series CL03-EV Qn = 700 l/min valve width: 16 mm plate connection compressed air connection output: Ø 8 - G 1/8 Manual override: detent single solenoid 21013 Certificates UR (Underwriters Laboratories) Version Spool valve, zero overlap External Sealing principle Soft sealing Blocking principle Single base plate principle Working pressure min./max. -0.9 bar / 10 bar Control pressure 2.5 bar / 10 bar min./max. Ambient temperature min./max. Medium temperature min./max. Medium Compressed air Max. particle size 40 µm Oil content of compressed air 0 mg/m³ - 10 mg/m³ With collective pilot air exhaust Degree of protection electrical connector/plug Protective circuit Status display LED IP 65, IP 67, IP 69K Duty cycle 100 % Switch-on time 16 ms Switch-off time 23 ms Generic emission standard in accordance EN 61000-6-4 Generic immunity standard in accordance EN 61000-6-2 Mounting screw M5 mounting screw tightening torque 2 Nm Tightening torque tolerance ±0,2 Weight 0.165 kg Z-diode Protected against polarity reversal Yellow Materials: Housing Seals Polyamide, fiber-glass reinforced Hydrogenated acrylonitrile butadiene rubber Technical Remarks The pressure dew point must be at least 15 C under ambient and medium temperature and may not exceed 3 C. The oil content of compressed air must remain constant during the life cycle. Use only the approved oils from Rexroth Pneumatics, see chapter Technical information. The pilot valve is UL (Underwriters Laboratories) certified. For series QR2 fittings, see Pneumatic connection technologies. The inner valve can be replaced by all series CL03 valves described under Valve systems. Operating Voltage tolerance Power consumption DC DC DC W 24 V -15% / +20% 0.35

Rexroth Pneumatics 13 5/2-directional valve, Series CL03-EV Qn = 700 l/min valve width: 16 mm plate connection compressed air connection output: Ø 8 - G 1/8 Manual override: detent single solenoid MO Compressed air connection Operating Input Output Exhaust connection control exhaust Flow conductance Flow rate value DC b C Qn Part No. [l/(s*bar)] [l/ min] Ø 8 Ø 8 Ø 8 Ø 4 Ø 4 R412017962 Ø 8 Ø 8 Ø 8 Ø 4 Ø 4 24 V 0.22 2.9 700 R412017963 G 1/8 G 1/8 G 1/8 M5 M5 R412017964 Part No. Note R412017962 1) R412017963 2) R412017964 - HHB = Manual override 1) push-in fitting: Brass, nickel-plated 2) push-in fitting: Stainless steel Nominal flow Qn at 6 bar and Δp = 1 bar

14 Rexroth Pneumatics 5/2-directional valve, Series CL03-EV Qn = 700 l/min valve width: 16 mm plate connection compressed air connection output: Ø 8 - G 1/8 Manual override: detent single solenoid Dimensions 50 110 23,6 12 32,5 69,4 34,6 170 4 1 3 168,2 189 45 2 Electrical connection: 1) Not connected 2) Solenoid 12 3) Ground 4) Solenoid 14 20458

Rexroth Pneumatics 15 5/2-directional valve, Series CL03-EV Qn = 700 l/min valve width: 16 mm plate connection compressed air connection output: Ø 8 - G 1/8 Manual override: detent double solenoid 21013 Certificates UR (Underwriters Laboratories) Version Spool valve, zero overlap External Sealing principle Soft sealing Blocking principle Single base plate principle Working pressure min./max. -0.9 bar / 10 bar Control pressure 2.5 bar / 10 bar min./max. Ambient temperature min./max. Medium temperature min./max. Medium Compressed air Max. particle size 40 µm Oil content of compressed air 0 mg/m³ - 10 mg/m³ With collective pilot air exhaust Degree of protection electrical connector/plug Protective circuit Status display LED IP 65, IP 67, IP 69K Duty cycle 100 % Switch-on time 13 ms Switch-off time 15 ms Generic emission standard in accordance EN 61000-6-4 Generic immunity standard in accordance EN 61000-6-2 Mounting screw M5 mounting screw tightening torque 2 Nm Tightening torque tolerance ±0,2 Weight 0.165 kg Z-diode Protected against polarity reversal Yellow Materials: Housing Seals Polyamide, fiber-glass reinforced Hydrogenated acrylonitrile butadiene rubber Technical Remarks The pressure dew point must be at least 15 C under ambient and medium temperature and may not exceed 3 C. The oil content of compressed air must remain constant during the life cycle. Use only the approved oils from Rexroth Pneumatics, see chapter Technical information. The pilot valve is UL (Underwriters Laboratories) certified. For series QR2 fittings, see Pneumatic connection technologies. The inner valve can be replaced by all series CL03 valves described under Valve systems. Operating Voltage tolerance Power consumption DC DC DC W 24 V -15% / +20% 0.35

16 Rexroth Pneumatics 5/2-directional valve, Series CL03-EV Qn = 700 l/min valve width: 16 mm plate connection compressed air connection output: Ø 8 - G 1/8 Manual override: detent double solenoid MO Compressed air connection Operating Input Output Exhaust connection control exhaust Flow conductance Flow rate value DC b C Qn Part No. [l/(s*bar)] [l/ min] Ø 8 Ø 8 Ø 8 Ø 4 Ø 4 R412017950 Ø 8 Ø 8 Ø 8 Ø 4 Ø 4 24 V 0.22 2.9 700 R412017951 G 1/8 G 1/8 G 1/8 M5 M5 R412017952 Part No. Note R412017950 1) R412017951 2) R412017952 - HHB = Manual override 1) push-in fitting: Brass, nickel-plated 2) push-in fitting: Stainless steel Nominal flow Qn at 6 bar and Δp = 1 bar

Rexroth Pneumatics 17 5/2-directional valve, Series CL03-EV Qn = 700 l/min valve width: 16 mm plate connection compressed air connection output: Ø 8 - G 1/8 Manual override: detent double solenoid Dimensions 50 110 23,6 12 32,5 69,4 34,6 170 4 1 3 168,2 189 45 2 Electrical connection: 1) Not connected 2) Solenoid 12 3) Ground 4) Solenoid 14 20458

18 Rexroth Pneumatics 5/3-directional valve, Series CL03-EV Qn = 700 l/min valve width: 16 mm plate connection compressed air connection output: Ø 8 - G 1/8 Manual override: detent 21013 Certificates UR (Underwriters Laboratories) Version Spool valve, zero overlap External Sealing principle Soft sealing Blocking principle Single base plate principle Working pressure min./max. -0.9 bar / 10 bar Control pressure 2.5 bar / 10 bar min./max. Ambient temperature min./max. Medium temperature min./max. Medium Compressed air Max. particle size 40 µm Oil content of compressed air 0 mg/m³ - 10 mg/m³ With collective pilot air exhaust Degree of protection electrical connector/plug Protective circuit Status display LED IP 65, IP 67, IP 69K Duty cycle 100 % Switch-on time 14 ms Switch-off time 15 ms Generic emission standard in accordance EN 61000-6-4 Generic immunity standard in accordance EN 61000-6-2 Mounting screw M5 mounting screw tightening torque 2 Nm Tightening torque tolerance ±0,2 Weight 0.165 kg Z-diode Protected against polarity reversal Yellow Materials: Housing Seals Polyamide, fiber-glass reinforced Acrylonitrile Butadiene Rubber Technical Remarks The pressure dew point must be at least 15 C under ambient and medium temperature and may not exceed 3 C. The oil content of compressed air must remain constant during the life cycle. Use only the approved oils from Rexroth Pneumatics, see chapter Technical information. The pilot valve is UL (Underwriters Laboratories) certified. For series QR2 fittings, see Pneumatic connection technologies. The inner valve can be replaced by all series CL03 valves described under Valve systems. Operating Voltage tolerance Power consumption DC DC DC W 24 V -15% / +20% 0.35

Rexroth Pneumatics 19 5/3-directional valve, Series CL03-EV Qn = 700 l/min valve width: 16 mm plate connection compressed air connection output: Ø 8 - G 1/8 Manual override: detent MO Compressed air connection Operating Input Output Exhaust connection control exhaust Flow conductance Flow rate value DC b C Qn Part No. [l/(s*bar)] [l/ min] Ø 8 Ø 8 Ø 8 Ø 4 Ø 4 R412017953 Ø 8 Ø 8 Ø 8 Ø 4 Ø 4 24 V 0.39 2.5 700 R412017954 G 1/8 G 1/8 G 1/8 M5 M5 R412017955 Part No. Note R412017953 1) R412017954 2) R412017955 - HHB = Manual override 1) push-in fitting: Brass, nickel-plated 2) push-in fitting: Stainless steel Nominal flow Qn at 6 bar and Δp = 1 bar

20 Rexroth Pneumatics 5/3-directional valve, Series CL03-EV Qn = 700 l/min valve width: 16 mm plate connection compressed air connection output: Ø 8 - G 1/8 Manual override: detent Dimensions 50 110 23,6 12 32,5 69,4 34,6 170 4 1 3 168,2 189 45 2 Electrical connection: 1) Not connected 2) Solenoid 12 3) Ground 4) Solenoid 14 20458

Rexroth Pneumatics 21 Series CL03-EV Accessories Connecting cable plug and socket Socket, M12x1, 4-pin, A-coded Plug, M12x1, 4-pin, A-coded Ambient temperature min./max. Protection class -25 C / +70 C IP 69K 00133750 Materials: Housing Cable sheath Stainless steel Polyvinyl chloride Technical Remarks The specified protection class is valid only in assembled and tested state. power supply Type Electrical interface Cable exit Bending radius min. Cable length L Weight Part No. [Port 1] [Port 2] [mm] [m] [kg] Socket, M12x1, 4-pin, A-coded Plug, M12x1, 4-pin, A-coded straight 54 5 0.258 R402003760 10 0.484 R402003761 15 0.699 R402003762 Dimensions Ø15 Ø15 42 48,5 L L = cable length 00133551

Bosch Rexroth Pneumatics GmbH Ulmer Straße 4 D - 30880 Laatzen Phone +49 511 2136-0 Fax +49 511 2136-2 69 info@rexrothpneumatics.com www.rexrothpneumatics.com Your contact: Canada Bosch Rexroth Pneumatics Inc. 3426 Mainway Drive Burlington, Ontario L7M 1A8 Tel. +1 905 332-0399 Fax +1 905 332-8596 Australia Bosch Rexroth Pty. Ltd. 3 Valediction Road Kings Park NSW 2148 Sydney Tel. +61 2 9831-7788 Fax +61 2 9831-5553 U.S.A. Bosch Rexroth Pneumatics Corp. 1953 Mercer Road Lexington, KY 40511 US Tel. +1 859 254-8031 Fax +1 859 254-4188 Great Britain Bosch Rexroth Pneumatics Ltd. Broadway Lane Cirencester, GL7 5UH Tel. +44 0845 60-30025 Fax +44 1285 86-3126 further contacts: www.rexrothpneumatics.com/en/ contact The data specifi ed above only serve to describe the product. No statements concerning a certain condition or suitability for a certain application can be derived from our information. The information given does not release the user from the obligation of own judgment and verifi cation. It must be remembered that our products are subject to a natural process of wear and aging. This document, as well as the data, specifi cations and other informations set forth in it, are the exclusive property of Bosch Rexroth Pneumatics GmbH. Without their consent it may not be reproduced or given to third parties. Subject to modifications. Online-PDF 28-11-2013