ACCESSORY KIT INSTALLATION MANUAL

Similar documents
ACCESSORY KIT INSTALLATION MANUAL

ACCESSORY KIT INSTALLATION MANUAL START KITS (2SA067*) FOR USE WITH MODELS: 13+ SEER AIR CONDITIONERS AND HEAT PUMPS

ACCESSORY KIT INSTALLATION MANUAL START KITS (2SA067*) FOR USE WITH MODELS: 13+ SEER AIR CONDITIONERS AND HEAT PUMPS

ACCESSORY KIT INSTALLATION INSTRUCTIONS

Furnace and A/C Parts

E1RA, E2RA SERIES - 10 SEER, 1PH & 3PH HEAT PUMP- OUTDOOR UNIT

H*BA SERIES, 10 SEER, 1PH & 3PH AIR CONDITIONER- OUTDOOR UNIT

LOW AMBIENT ACCESSORY INSTALLATION INSTRUCTION

B2HZ SERIES - 13 SEER SINGLE PACKAGED HEAT PUMPS (R-410A, STYLE A,B)

E4FH, E5FH SERIES 12 SEER HEAT PUMP

ACCESSORY KIT INSTALLATION INSTRUCTIONS

NL SERIES - 13 SEER SINGLE PACKAGED AIR CONDITIONER (R-410A, STYLE B)

ACCESSORY KIT INSTALLATION INSTRUCTIONS

TECHNICAL SUPPORT MANUAL Split System Heat Pump R2HM, R2H3, WCH3**2

UARDIAN TECHNICAL GUIDE MODELS: GCGD18 THRU 60

ACCESSORY KIT INSTALLATION INSTRUCTIONS

13PJA. Heat Pumps. Parts List 20-July-2015

INSTALLATION INSTRUCTIONS

ACCESSORY KIT INSTALLATION INSTRUCTIONS

LX SERIES 16 SEER MULTI-SPLIT DUCTLESS, HEAT PUMPS

INSTALLATION INSTRUCTIONS FOR EGA AND EGH SERIES ELECTRIC HEATERS IN V OR H SERIES UNITS

SUNLINE 2000 SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS FEATURES DESCRIPTION. H5CE090 & H3CE AND 10 NOMINAL TONS (World 50HZ)

ELECTRIC HEAT ACCESSORY INSTALLATION INSTRUCTION. 20, 30 & 40 kw for 15 Ton Split System Air Conditioners Models: LB180 & LL A-0102

ACCESSORY KIT INSTALLATION INSTRUCTIONS

Replacement Parts List

LX SERIES 16 SEER MULTI-SPLIT DUCTLESS, HEAT PUMPS

TECHNICAL SUPPORT MANUAL Split System Heat Pump N2H3**C (Coastal)

ACCESSORY KIT INSTALLATION INSTRUCTIONS

ACCESSORY KIT INSTALLATION INSTRUCTIONS

MODELS DSH/KSH/DSV/KSV R-410A LOW-AMBIENT KIT

ZHA/ZHB SERIES WARNING

SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS DESCRIPTION FEATURES H2CA300, 360, 480 & THRU 50 NOMINAL TONS

Eclipse 2000 Service Parts

This parts list is current as of the above revision date. See for the current revision.

ACCESSORY KIT INSTALLATION INSTRUCTIONS Low Ambient Accessory For Air Cooled Split System Air Conditioners HB 180/240, HF -15,-20 Models Only

TECHNICAL SUPPORT MANUAL Split System Air Conditioner N2A0, 3-Phase

PREMIUM SERIES 22 SEER SINGLE SPLIT DUCTLESS, COOLING SYSTEMS (CONTAINS INDOOR AND OUTDOOR MODELS)

INSTALLATION INSTRUCTION

HBW Compressor Order List 2015

PHE4 SERIES - 14 SEER SINGLE PACKAGED ELECTRIC HEAT PUMP (R-410A, STYLE A)

REPLACEMENT PARTS MANUAL

TECHNICAL SUPPORT MANUAL Split System Air Conditioner N2A3, 3-Phase

This parts list is current as of the above revision date. See for the current revision.

ACCESSORY KIT INSTALLATION INSTRUCTIONS

ACCESSORY KIT INSTALLATION INSTRUCTIONS

SUNLINE 2000 SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS DESCRIPTION FEATURES H4CE090 & H2CE120 & H1CE /2, 10, & 12-1/2 NOMINAL TONS

TECHNICAL GUIDE LISTED TECHNICAL GUIDE SPLIT-SYSTEM AIR CONDITIONERS 13 SEER R-410A 3 PHASE MODELS: TCGD30 THRU 60 (2.5 THRU 5 NOMINAL TONS)

REPAIR PART INSTALLATION INSTRUCTIONS

This parts list is current as of the above revision date. See for the current revision.

PREMIUM SERIES 22 SEER SINGLE SPLIT DUCTLESS, HEAT PUMP SYSTEMS (CONTAINS INDOOR AND OUTDOOR MODELS)

INSTALLATION INSTRUCTION ELECTRIC HEATER ACCESSORY MODELS 2NH THRU 2NH045025, 2NP THRU 2NP045025, 2ND , AND 2NX GENERAL

PREMIUM SERIES 22 SEER SINGLE SPLIT DUCTLESS, HEAT PUMP SYSTEMS (CONTAINS INDOOR AND OUTDOOR MODELS)

F2FP (G), F3FP (TG) SERIES FAN COIL UNIT

LX SERIES 16 SEER SINGLE SPLIT DUCTLESS, HEAT PUMP SYSTEMS (CONTAINS INDOOR AND OUTDOOR MODELS)

CHILLER MODEL NO. YS SOLID STATE STARTER, MODEL NO. SSS, L B OPTIONAL FACTORY INSTALLED DISCONNECT SWITCH AMPS OR

AIR CONDITIONER PACKAGED UNIT

DZ14S Commercial 3-5 TON, THREE-PHASE SPLIT SYSTEM HEAT PUMP 14 SEER / R-410A

TECHNICAL GUIDE DESCRIPTION MODELS: D4HH 024 THRU 180 HORIZONTAL FEATURES SINGLE PACKAGE AIR CONDITIONERS HORIZONTAL INDOOR & CONDENSER AIR FLOW

INSTALLATION INSTRUCTION ELECTRIC HEATER ACCESSORY MODELS 2NH THRU 2NH045025, 2NP THRU 2NP045025, 2ND , AND 2NX GENERAL

DESCRIPTION ACCESSORIES FIELD INSTALLED SPLIT-SYSTEM EVAPORATOR BLOWERS KBBU060, KDBC090, KCBC120 & KCBC180 5 THRU 15 NOMINAL TONS SUPPLY AIR PLENUMS

TECHNICAL SUPPORT MANUAL Split System Air Conditioner (C,H,T)4A3

INSTALLATION INSTRUCTIONS CMH-21 Low Ambient 460V Fan Speed Control

FIELD CONNECTIONS FOR YK CHILLER (STYLE G) OPTIVIEW CONTROL CENTER WITH REMOTE MEDIUM VOLTAGE SSS

OEZ IEZ NOMENCLATURE STANDARD FEATURES FACTORY INSTALLED OPTIONS

TECHNICAL GUIDE. Echelon MODELS: FC8S GAS-FIRED HIGH EFFICIENCY SINGLE STAGE DOWNFLOW FURNACES 80% AFUE DESCRIPTION WARRANTY FEATURES

INSTALLATION INSTRUCTIONS

LUI / LUO. Condensing Units

Parts List. Stackable Crescent Cuber. Models KM-1601MRJ/3. hoshizakiamerica.com

DESCRIPTION FEATURES

TECHNICAL GUIDE 16 SEER 2-5 TON AIR CONDITIONING SPLIT-SYSTEM COOLING H4TS024 H4TS030 H4TS036 H4TS048 H4TS060 DESCRIPTION FEATURES MODELS:

This parts list is current as of the above revision date. See for the current revision.

TECHNICAL SUPPORT MANUAL Split System Air Conditioner H4A3, 3 Phase

12 CB30M SERIES UNITS INCLUDING ECB29 ELECTRIC HEAT

Elegant. Floor Standing Split Systems 53QFJ HEAT PUMP SPARE PARTS MANUAL

TECHNICAL GUIDE AFFINITY MODELS: PS8 GAS-FIRED HIGH EFFICIENCY SINGLE STAGE DOWNFLOW FURNACES 80% AFUE DESCRIPTION WARRANTY FEATURES

See Page 4 for details

TECHNICAL MANUAL. GSC/VSC13 SEER Condensing Units with R-22

TECHNICAL GUIDE LISTED SPLIT-SYSTEM HEAT PUMPS 13 SEER R-410A MODELS: THGD30 THRU 60 (2.5 THRU 5 NOMINAL TONS - 3 PHASE)

TECHNICAL SPECIFICATIONS

ASZ13 13 SEER / R-410A. Heating Capacity: 18,000-59,000 BTU/h

Installation Instructions

TECHNICAL SUPPORT MANUAL Split System Air Conditioner N2A3

TECHNICAL SUPPORT MANUAL Split System Heat Pump H2H3, 3 Phase

INSTALLATION INSTRUCTIONS CMH-7A LOW AMBIENT CONTROL

TECHNICAL GUIDE LISTED SPLIT-SYSTEM AIR CONDITIONERS 12 SEER MODELS: AC018X12* THRU 060 (1.5 THRU 5 NOMINAL TONS, 1 PH)

EasyStart Installation Instructions for Dometic Family RV A/Cs

ACCESSORY KIT INSTALLATION INSTRUCTIONS

TECHNICAL SPECIFICATIONS

SPLIT-SYSTEM EVAPORATOR BLOWER DESCRIPTION ACCESSORIES EER 8.5 ARI RATINGS* K2ES120A25 10 NOMINAL TONS WITH TWO 5 TON CIRCUITS

Installation Instructions

Installation Instructions

Installation Instructions

SERVICE MANUAL (INTERNATIONAL)

FAST-STAT. Model 3000 Installation Instructions. Application. Troubleshooting not operating. Before Installing This Product. Sender Installation

Replacement Parts, W/D & Tech Data HHP Series

GSX 16 SEER Condensing Units

TECHNICAL INFORMATION MANUAL

FHC-1D user manual. Features

H4A3. Product Specifications EFFICIENT 13 SEER AIR CONDITIONER

Installation Instructions

Transcription:

ACCESSORY KIT INSTALLATION MANUAL 2SA067* START KITS FOR 13+ SEER AIR CONDITIONERS AND HEAT PUMPS GENERAL INFORAMTION Persons not qualified shall not install this equipment or interpret these instructions. These instructions are intended for the use of qualified individuals specially trained and experienced in installation of this type of equipment and related system components. Installation and service personnel are required by some states to be licensed. Improper installation may damage equipment, can create a shock hazard, and will void the warranty. NOTE: The words Shall" or Must" indicate a requirement which is essential to satisfactory and safe product performance. The words Should" or May" indicate a recommendation or advice which is not essential and not required but which may be useful or helpful. Contents of Kit The compressor starting kit consists of a potential (starting) relay, screws, capacitor strap and starting capacitor with wiring leads. Kit may contain more hardware than necessary for some models and wires may be longer than required. Start kits for the various models are listed in Table 1. APPLICATION The compressor in the outdoor unit has a PSC (permanent split capacitor) motor which does not require a starting relay and capacitor, under ordinary operating conditions. The omission of these components eliminates a potential source of field problems making the system more trouble-free. In order to take advantage of these benefits and trouble-free operation, the starting torque, or load, must be kept to a minimum. The suction and discharge pressures must be nearly equal before the compressor will start. Because of the lower starting torque inherent in PSC motors, certain conditions such as low voltage and exceptionally high operating temperature, short thermostat cycles, etc. can affect the starting operation. When such conditions exist, and cannot be corrected, it is recommended that the field installed compressor starting kit be used to convert the compressor motor to CSR (capacitor, capacitor run) operation. NOTE: All Start Kits listed in these instructions are for use with outdoor units rated at 208-230V/ 1PH/60Hz. SHOCK HAZARD - Shut off electrical supply to outdoor unit at main disconnect. One side of the contactor remains closed at all times, so main disconnect must be opened when servicing electrical components to prevent electrical shock, which could result in personal injury or death. Do not mis-match kits or damage will occur to the equipment. TABLE 1: Start Kits Start Kit Model Number Outdoor Unit Model Number Compressor See Section for Installation S1-2SA06704006 ERCS0421CA HABD/H1RD042 AC042X1321 Copeland (ZR36K3-PFV) A S1-2SA06704006 ERCS0481CA HABD/H1RD048 AC048X1321 Copeland (ZR42K3-PFV) A S1-2SA06702006 ERCS0181BB HBBD/H2RD018 AC018X1322 Bristol (H21J14BABCA) A S1-2SA06705906 ERCS0301BB HBBD/H2RD030 AC030X1322 Bristol (H21J25BABCA) A S1-2SA06708106 ERCS0361BB HBBD/H2RD036 AC036X1322 Bristol (H21J30BABCA) A S1-2SA06708006 ERCS0481BB HBBD/H2RD048 AC048X1322 Bristol (H23C453ABCA) A S1-2SA06707906 ERCS0601BB HBBD/H2RD060 AC060X1322 Bristol (H23R543ABCA) A S1-2SA06705906 ERCQ0301BB Bristol (H21J25BABCA) A S1-2SA06705406 ERCQ0361BB Bristol (H21J30BABCA) A S1-2SA06708006 ERCQ0481BB Bristol (H23C453ABCA) A S1-2SA06708106 ERHS0361BA EABD/E1RD036 HP036X1321 Bristol (H21J30BABCA) B S1-2SA06708106 ERHS0421BA EABD/E1RD042 HP042X1321 Bristol (H21J36BABCA) B S1-2SA06708006 ERHS0481BA EABD/E1RD048 HP048X1321 Bristol (H23C423ABCA) B S1-2SA06707906 ERHS0601BA EABD/E1RD060 HP060X1321 Bristol (H23R543ABCA) B S1-2SA06705406 ERHQ0361BA Bristol (H21J30BABCA) B Johnson Controls Unitary Products 364024-UAI-B-0509

TABLE 1: Start Kits (Continued) Start Kit Model Number Outdoor Unit Model Number Compressor See Section for Installation S1-2SA06705406 ERHQ0421BA Bristol (H21J36BABCA) B S1-2SA06702006 FRCS0181BA HABE/H1RE018 Bristol (H21J14BABCA) A S1-2SA06705506 FRCS0241BF HCBE/H3RE024 Bristol (H21J20BABCA) A S1-2SA06721706 FRCS0241BH HDBE/H4RE024 Bristol (H21J17BABCA) A S1-2SA06705906 FRCS0301BF HCBE/H3RE030 Bristol (H21J24BABCA) A S1-2SA06707906 FRCS0601BF HCBE/H3RE060 Bristol (H23R543ABCA) B S1-2SA06702006 AC3A018F1 CMB01811 AL3A018F1 Bristol (H21J15BABCA) C S1-2SA06705506 AC3A024F1 CMB02411 AL3A024F1 Bristol (H21J20BABCA) C S1-2SA06705906 AC3A030F1 CMB03011 AL3A030F1 Bristol (H21J25BABCA) C S1-2SA06708106 AC3A036F1 CMB03611 AL3A036F1 Bristol (H21J30BABCA) C S1-2SA06708006 AC3A042F1 CMB04211 AL3A042F1 Bristol (H23C383ABCA) C S1-2SA06708006 AC3A048F1 CMB04811 AL3A048F1 Bristol (H23C453ABCA) C S1-2SA06707906 AC3A060F1 CMB06011 AL3A060F1 Bristol (H23R543ABCA) C S1-2SA06704006 HC3H018F1 YMB01811 HL3H018F1 Copeland (ZR16K4-PFV) D S1-2SA06704006 HC3H024F1 YMB02411 HL3H024F1 Copeland (ZR22K4-PFV) D S1-2SA06704006 HC3H030F1 YMB03011 HL3H030F1 Copeland (ZR26K3-PFV) D S1-2SA06708106 HC3H036F1 YMB03611 HL3H036F1 Bristol (H21J30BABCA) D S1-2SA06708006 HC3H042F1 YMB04211 HL3H042F1 Bristol (H23C383ABCA) D S1-2SA06708006 HC3H048F1 YMB04811 HL3H048F1 Bristol (H23C453ABCA) D S1-2SA06707906 HC3H060F1 YMB06011 HL3H060F1 Bristol (H23R543ABCA) D S1-2SA06705406 AY036MA321 AM036MA321 Bristol (H21J30BABCA) E S1-2SA06708506 AY012MA322 AM012MA322 Panasonic (2K20S236T6A) E S1-2SA06708606 AY018MA322 AM018MA322 Panasonic (2K22S236SUB) E S1-2SA06705506 AY024MA322 AM024MA322 Bristol (H21J20BABCA) E S1-2SA06708106 AY030MA322 AM030MA322 Bristol (H21J24BABCA) E S1-2SA06708606 TCGD12S21S(1,2) GCGD12S21S(1,2) Panasonic (2K15S236UUA) F S1-2SA06708606 TCGD18S21S(1,2) GCGD18S21S(1,2) Panasonic (2K22S236SUB) F S1-2SA06708706 TCGD24S21S(1,2) GCGD24S21S(1,2) Panasonic (2J29S236B1A) F S1-2SA06705906 TCGD30S21S(1,2) GCGD30S21S(1,2) Bristol (H21J24BABCA) F S1-2SA06708106 TCGD36S21S(1,2) GCGD36S21S(1,2) Bristol (H21J30BABCA) F S1-2SA06708106 TCGD42S21S(1,2) GCGD42S21S(1,2) Bristol (H21J36BABCA) F S1-2SA06708806 TCGD48S21S(1,2) GCGD48S21S(1,2) Bristol (H21J38BABCA) F S1-2SA06707906 TCGD60S21S(1,2) GCGD60S21S(1,2) Danfoss (HRM051U1LP) F S1-2SA067121706 TCGD24S21S2X GCGD24S21S2X Bristol (H21J19BABCA) F S1-2SA06708606 TCGD18S41S1 Panasonic 5KS150FAB21 F S1-2SA06708606 YCJD18S41S1 CCJD18S41S1 LCJD18S41S1 Panasonic 5KS150FAB21 F S1-2SA06721706 TCGD24S41S1 Bristol H82J193ABCA F S1-2SA06721706 YCJD24S41S1 CCJD24S41S1 LCJD24S41S1 Bristol H82J193ABCA F S1-2SA06709206 TCGD30S41S1 Bristol H82J193ABCA F S1-2SA06709206 YCJD30S41S1 CCJD30S41S1 LCJD30S41S1 Bristol H82J193ABCA F S1-2SA06708906 TCGD36S41S1 Bristol H82J273ABCA F S1-2SA06708906 YCJD36S41S1 CCJD36S41S1 LCJD36S41S1 Bristol H82J273ABCA F S1-2SA06708806 TCGD42S41S1 Bristol H82J353ABCA F S1-2SA06708806 YCJD42S41S1 CCJD42S41S1 LCJD42S41S1 Bristol H82J353ABCA F S1-2SA06708806 TCGD48S41S1 Bristol H82J373ABCA F S1-2SA06708806 YCJD48S41S1 CCJD48S41S1 LCJD48S41S1 Bristol H82J373ABCA F 2 Johnson Controls Unitary Products

TABLE 1: Start Kits (Continued) Start Kit Model Number Outdoor Unit Model Number Compressor See Section for Installation S1-2SA06704006 TCGF24S41S1 Copeland ZP21K5PFV-130 F S1-2SA06704006 YCJF24S41S1 CCJF24S41S1 LCJF24S41S1 Copeland ZP21K5PFV-130 F S1-2SA06704006 TCGF30S41S1 Copeland ZP29K5PFV-130 F S1-2SA06704006 YCJF30S41S1 CCJF30S41S1 LCJF30S41S1 Copeland ZP29K5PFV-130 F S1-2SA06704006 TCGF36S41S1 Copeland ZP29K5PFV-130 F S1-2SA06704006 YCJF36S41S1 CCJF36S41S1 LCJF36S41S1 Copeland ZP29K5PFV-130 F S1-2SA06704006 TCGF42S41S1 Copeland ZP34K5PFV-130 F S1-2SA06704006 YCJF42S41S1 CCJF42S41S1 LCJF42S41S1 Copeland ZP34K5PFV-130 F S1-2SA06708006 TCGF48S41S1 Danfoss HRH038U1LP F S1-2SA06708006 YCJF48S41S1 CCJF48S41S1 LCJF48S41S1 Danfoss HRH038U1LP F S1-2SA06707906 TCGF60S41S1 Danfoss (HRH047U1LP) F S1-2SA06707906 YCJF60S41S1 CCJF60S41S1 LCJF60S41S1 Danfoss (HRH047U1LP) F S1-2SA06704006 THGD18S41S2 GHGD18S41S2 ZP16K5E-PFV G S1-2SA06704006 YHJD18S41S2 CHJD18S41S2 LHJD18S41S2 ZP16K5E-PFV G S1-2SA06721706 THGD24S41S2 GHGD24S41S2 H82J183ABCA G S1-2SA06721706 YHJD24S41S2 CHJD24S41S2 LHJD24S41S2 H82J183ABCA G S1-2SA06709206 THGD30S41S2 GHGD30S41S2 H82J223ABCA G S1-2SA06709206 YHJD30S41S2 CHJD30S41S2 LHJD30S41S2 H82J223ABCA G S1-2SA06708906 THGD36S41S2 GHGD36S41S2 H82J283ABCA G S1-2SA06708906 YHJD36S41S2 CHJD36S41S2 LHJD36S41S2 H82J283ABCA G S1-2SA06708006 THGD42S41S1 GHGD42S41S1 HRH036U1LP6 G S1-2SA06708006 YHJD42S41S1 CHJD42S41S1 LHGD42S41S1 HRH036U1LP6 G S1-2SA06707906 THGD48S41S1 GHGD48S41S1 HRH041U1LP6 G S1-2SA06707906 YHJD48S41S1 CHJD48S41S1 LHGD48S41S1 HRH041U1LP6 G S1-2SA06707906 THGD60S41S1 GHGD60S41S1 HRH049U1LP6 G S1-2SA06707906 YHJD60S41S1 CHJD60S41S1 LHGD60S41S1 HRH049U1LP6 G S1-2SA06704006 THGF18S41S2 ZP16K5E-PFV G S1-2SA06704006 YHJD18S41S2 CHJD18S41S2 LHJD18S41S2 ZP16K5E-PFV G S1-2SA06704006 THGF24S41S2 ZP20K5E-PFV G S1-2SA06704006 YHJD24S41S2 CHJD24S41S2 LHJD24S41S2 ZP20K5E-PFV G S1-2SA06704006 THGF30S41S2 ZP24K5E-PFV G S1-2SA06704006 YHJD30S41S2 CHJD30S41S2 LHJD30S41S2 ZP24K5E-PFV G TBD THGF36S41S2 HRH031U1LP6 G TBD YHJD36S41S2 CHJD36S41S2 LHJD36S41S2 HRH031U1LP6 G S1-2SA06708006 THGF42S41S1 HRH034U1LP6 G S1-2SA06708006 YHJD42S41S1 CHJD42S41S1 LHGF42S41S1 HRH034U1LP6 G S1-2SA06708006 THGF42S41S2 HRH034U1LP6 G S1-2SA06708006 YHJD42S41S2 CHJD42S41S2 LHGF42S41S2 HRH034U1LP6 G S1-2SA06708006 THGF48S41S1 HRH040U1LP6 G S1-2SA06708006 YHJD48S41S1 CHJD48S41S1 LHGF48S41S1 HRH040U1LP6 G THGF60S41S1 ZPS51K4E-PFV G YHJD60S41S1 CHJD60S41S1 LHGF60S41S1 ZPS51K4E-PFV G S1-2SA06707906 THRD60S41S1 GHRD60S41S1 HRH049U1LP6 G S1-2SA06708006 CHGD42S41S1 HRH036U1LP6 G Johnson Controls Unitary Products 3

SECTION A HRD, HBD, ERCS, AC(13), ERCQ, HRE, HBE & FRCS SERIES SPLIT AIR CONDITIONERS Pre-drilled pilot holes are provided in the control box. 1. Use the two pilot holes on the left angled side to at-tach start relay. See Figure 1. 2. Place the start capacitor beside the dual capacitor using one capacitor strap fastened to pilot holes provided in control box to secure both capacitors in place. 3. Attach the black lead wire from the starting kit relay #5 to T1 terminal of the contactor. 4. Attach the red lead wire from the starting kit capacitor to T2 terminal of the contactor. 5. Locate the brown wire connecting the dual capacitor "HERM" to the S (start) terminal on the compressor. 6. Attach the brown lead wire from the starting kit relay #2 to the same terminal on the dual capacitor which was located in Step 4. See Figure 2. 7. The yellow lead wire should be factory connected between starting kit relay #1 to starting kit capacitor. NOTE: The wiring of the capacitor and relay must agree with Figure 2. Also, see diagram on control box cover. DUAL RUN/FAN FIGURE 1 START RELAY START CONTACTOR 1 2 3 4 5 COMPONENTS SHOWN IN DASHED LINES ARE OPTIONAL.. DUAL SHOWN SEPARATE S MAY BE USED ON ACTUAL UNIT. WIRING MUST CONFORM TO NATIONAL AND LOCAL CODES. IF ANY OF THE ORIGINAL WIRE SUPPLIED WITH THIS UNIT MUST BE REPLACED, IT MUST BE REPLACED WITH TYPE 105 C. THERMOPLASTIC OR ITS EQUIVALENT. WHERE POWER SUPPLY HAS ONE (1) 240 VOLT CONDUCTOR AND ONE (1) NEUTRAL CONDUCTOR, CONNECT L2 OF CONTACTOR TO NEUTRAL.. HTS HPS CCH HS SR SC CC - HIGH TEMPERATURE SWITCH - HIGH PRESSURE SWITCH - CRANKCASE HEATER - HEATER SWITCH - START RELAY - START - CONTACTOR COIL HIGH VOLTAGE FACTORY WIRING LOW VOLTAGE FACTORY WIRING OPTIONAL WIRING FIELD WIRING, LINE VOLTAGE FIGURE 2 4 Johnson Controls Unitary Products

SECTION B ERD, EBD, ERHS, HP(13) & ERHQ SERIES SPLIT HEAT PUMPS Pre-drilled pilot holes are provided in the control box. NOTE: On units which have a solid state start device, remove 5the device and the red and brown wiring connections to the dual capacitor. 1. Use the two pilot holes on the left angled side to attach start relay. See Figure 3. 2. Place the start capacitor beside the dual capacitor using one capacitor strap fastened to pilot holes provided in control box to secure both capacitors in place. 3. Attach the black lead wire from the starting kit relay #5 to T1 terminal of the contactor. 4. Attach the red lead wire from the starting kit capacitor to T2 terminal of the contactor. 5. Locate the brown wire connecting the dual capacitor "HERM" to the S (start) terminal on the compressor. 6. Attach the brown lead wire from the starting kit relay #2 to the same terminal on the dual capacitor which was located in Step 4. See Figure 4. 7. The yellow lead wire should be factory connected between starting kit relay #1 to starting kit capacitor. NOTE: The wiring of the capacitor and relay must agree with Figure 4. Also, see diagram on control box cover. DUAL RUN/FAN FIGURE 3 START RELAY START CONTACTOR Johnson Controls Unitary Products 5

FIGURE 4 6 Johnson Controls Unitary Products

SECTION C CMB, AC3 & AL3 SERIES SPLIT AIR CONDI- TIONERS Pre-drilled pilot holes are provided in the control box. 1. Use the two pilot holes on the left angled side to at-tach start relay. See Figure 1. 2. Place the start capacitor beside the dual capacitor using one capacitor strap fastened to pilot holes provided in control box to secure both capacitors in place. 3. Attach the black lead wire from the starting kit relay #5 to T1 terminal of the contactor. 4. Attach the red lead wire from the starting kit capacitor to T2 terminal of the contactor. 5. Locate the brown wire connecting the dual capacitor "HERM" to the S (start) terminal on the compressor. 6. Attach the brown lead wire from the starting kit relay #2 to the same terminal on the dual capacitor which was located in Step 4. See Figure 2. 7. The yellow lead wire should be factory connected between starting kit relay #1 to starting kit capacitor. NOTE: The wiring of the capacitor and relay must agree with Figure 2. Also, see diagram on control box cover. START RELAY FIGURE 5 START FAN CONTROL (CZE038 model only) DUAL RUN / FAN COMFORT ALERT MODULE CONTACTOR Johnson Controls Unitary Products 7

FIGURE 6 8 Johnson Controls Unitary Products

SECTION D YMB, HC3 & HL3 SERIES SPLIT HEAT PUMPS Pre-drilled pilot holes are provided in the control box. NOTE: On units which have a solid state start device, remove 5the device and the red and brown wiring connections to the dual capacitor. 1. Use the two pilot holes on the left angled side to attach start relay. See Figure 3. 2. Place the start capacitor beside the dual capacitor using one capacitor strap fastened to pilot holes provided in control box to secure both capacitors in place. 3. Attach the black lead wire from the starting kit relay #5 to T1 terminal of the contactor. 4. Attach the red lead wire from the starting kit capacitor to T2 terminal of the contactor. 5. Locate the brown wire connecting the dual capacitor "HERM" to the S (start) terminal on the compressor. 6. Attach the brown lead wire from the starting kit relay #2 to the same terminal on the dual capacitor which was located in Step 4. See Figure 4. 7. The yellow lead wire should be factory connected between starting kit relay #1 to starting kit capacitor. NOTE: The wiring of the capacitor and relay must agree with Figure 4. Also, see diagram on control box cover. START RELAY RELAY DEFROST CONTROL BOARD START DUAL RUN / FAN TRANSFORMER CONTACTOR FIGURE 7 Johnson Controls Unitary Products 9

FIGURE 8 10 Johnson Controls Unitary Products

FIGURE 9 (HC5B, HL5B, YZE024, 036, 048, 060) Johnson Controls Unitary Products 11

FIGURE 10 (YZE038 Only) 12 Johnson Controls Unitary Products

SECTION E AM & AY SERIES SPLIT AIR CONDITIONERS Pre-drilled pilot holes are provided in the control box. 1. Use the two pilot holes to attach start relay. See Figure 11. 2. Place the start capacitor beside the dual capacitor using one capacitor strap fastened to pilot holes provided in control box to secure both capacitors in place. 3. Attach the black lead wire from the starting kit relay #5 to T1 terminal of the contactor. 4. Attach the red lead wire from the starting kit capacitor to T2 terminal of the contactor. 5. Locate the brown wire connecting the dual capacitor "HERM" to the S (start) terminal on the compressor. 6. Attach the brown lead wire from the starting kit relay #2 to the same terminal on the dual capacitor which was located in Step 4. See Figure 13. 7. The yellow lead wire should be factory connected between starting kit relay #1 to starting kit capacitor. NOTE: The wiring of the capacitor and relay must agree with Figure 13. Also, see diagram on control box cover. CONTACTOR START RELAY SECTION F TCGD, GCGD, YCJD, CCJD, LCJD, TCGF, YCJF, CCJF, LCJF SERIES SPLIT AIR CONDITIONERS Pre-drilled pilot holes are provided in the control box. 1. Use the pilot hole behind start relay sticker to attach start relay. see Figure 12. 2. Place the start capacitor beside the dual capacitor using one capacitor strap fastened to pilot holes provided in control box to secure both capacitors in place. 3. Attach the black lead wire from the starting kit relay #5 to T1 terminal of the contactor. 4. Attach the red lead wire from the starting kit capacitor to T2 terminal of the contactor. 5. Locate the brown wire connecting the dual capacitor "HERM" to the S (start) terminal on the compressor. 6. Attach the brown lead wire from the starting kit relay #2 to the same terminal on the dual capacitor which was located in Step 4. See Figure 13. 7. The yellow lead wire should be factory connected between starting kit relay #1 to starting kit capacitor. NOTE: The wiring of the capacitor and relay must agree with Figure 13. Also, see diagram on control box cover. CONTACTOR START RELAY START FIGURE 11 DUAL RUN/FAN START DUAL RUN/FAN FIGURE 12 Johnson Controls Unitary Products 13

FIGURE 13 14 Johnson Controls Unitary Products

SECTION G THGD, GHGD, YHJD, CHJD, LHJD, THRD, GHRD, CHGD, THGF, YHJF, CHJF, LHJF SERIES SPLIT HEAT PUMPS Pre-drilled pilot holes are provided in the control box. 1. Use the pilot hole behind start relay sticker to attach start relay. see Figure 12. 2. Place the start capacitor beside the dual capacitor using one capacitor strap fastened to pilot holes provided in control box to secure both capacitors in place. 3. Attach the black lead wire from the starting kit relay #5 to T1 terminal of the contactor. 4. Attach the red lead wire from the starting kit capacitor to T2 terminal of the contactor. 5. Locate the brown wire connecting the dual capacitor "HERM" to the S (start) terminal on the compressor. 6. Attach the brown lead wire from the starting kit relay #2 to the same terminal on the dual capacitor which was located in Step 4. See Figures 15 or 16. 7. The yellow lead wire should be factory connected between starting kit relay #1 to starting kit capacitor. NOTE: The wiring of the capacitor and relay must agree with Figures 15 or 16. Also, see diagram on control box cover. Defrost Control Board Low Voltage Box Fingered Bushing Reversible High Voltage Conduit Plate FIGURE 14 Ground Lug Contactor Start Relay (Optional) Start Capacitor (Optional) Dual Run/Fan Capacitor Johnson Controls Unitary Products 15

FIGURE 15 Wiring Diagram - Single Phase - 13 SEER & 14.5 SEER (except 060) Heat Pumps 16 Johnson Controls Unitary Products

FIGURE 16 Wiring Diagram - Single Phase - 14.5 SEER (060 only) Heat Pump Johnson Controls Unitary Products 17

Kit Numbers Start Capacitor Ratings Component Ratings Start Relay Ratings Cold Pick-up Drop-out Rated Hot Pick-up Volts MIN. MAX. MIN. MAX. 2SA06702006 145-175 mfd. 250 VAC 170 180 162 175 40 90 2SA06704006 88-108 mfd. 330 VAC 170 180 162 175 40 90 2SA06705406 145-175 mfd. 250 VAC 200 220 186 215 40 90 2SA06705506 145-175 mfd. 250 VAC 160 170 152 166 40 90 2SA06705906 145-175 mfd. 250 VAC 190 200 180 195 40 90 2SA06707906 161-193 mfd. 250 VAC 140 150 132 148 40 90 2SA06708006 88-108 mfd. 330 VAC 140 150 132 148 40 90 2SA06708106 189-227 mfd. 330 VAC 190 200 180 193 40 90 2SA06708506 189-227 mfd. 330VAC 220 240 203 231 35 77 2SA06708606 189-227 mfd. 330VAC 260 280 240 269 35 77 2SA06708706 324-388 mfd. 330VAC 240 260 224 252 40 90 2SA06708806 189-227 mfd. 250VAC 190 200 180 193 40 90 2SA06708906 189-227 mfd. 250VAC 140 150 132 148 40 90 2SA06721706 145-175 mfd. 330VAC 200 220 186 215 40 90 2SA06709206 145-175 mfd. 330VAC 160 170 152 166 40 90 2SA06709306 145-175 mfd. 250VAC 150 160 142 157 40 90 2SA06709406 270-374 mfd. 250VAC 140 150 132 148 40 90 Subject to change without notice. Published in U.S.A. Copyright 2009 by Johnson Controls, Inc. All rights reserved. Johnson Controls Unitary Products 5005 York Drive Norman, OK 73069 364024-UAI-B-0509 Supersedes: 364024-UAI-A-0208