Rittal TopTherm Filter Fans

Similar documents
TopTherm Filter Fans

Rittal TopTherm fan-and-filter unit

Catalog / 2016 North American Edition

aus SK 2000, S. 134 Mounting cutout 100.5

17-38 CFM Filterfans PF GEN4 Series Type 12

Catalog / 2016 North American Edition

Operating voltage 120, 230 V AC Air volume 24 m³/h (14.1 CFM) Rated power 13 W Size 1

Air volume 24 m³/h (14.1 CFM) Rated power 13 W Size (14.1) 55 (32.4) 100 (58.9) Air volume (with exhaust filter installed)

THE CALCULATION THAT MAKES SENSE!

More efficiency with the base/plinth system VX

Compact Cooling Units

Climate Control Products

CLIMATE CONTROL PRODUCTS

Outdoor system solutions

The calculation that makes sense!

2 Rittal climate control/wall-mounted cooling units Blue e+

TS IT Server/Network Enclosures

1.6 Accessories include tool-free snap-in technology options for air flow, cable management, shelves, power distribution units, etc.

Outdoor system solutions

CLIMATE CONTROL SOLUTION

Our expertise your benefit. AE Available off the shelf.

ACCESSORIES FOR SZE2 CABINETS

TS 8 Specification Guide

Elegant-wall 19inch wall mounting rack cabinet W:600 = D:600

Knürr Smaract. Knürr Smaract. CompactRack

TS 8 Bayed Enclosure System

THE NEW TS IT RACK 8

Knürr CoolBlast. Top-Mounting Fan for Miracel

Blue e+ chillers with the principle

SE 8 Delivers Greater Durability and Customization Over Unibody Enclosures

JB & WM Specification Guide

Power consumption In operation At rest For wire sizing. Torque Inhibiting torque. 150 s / C Sound power level Motor

Rittal The System. Rittal JB and WM Specification Guide. Faster Better Worldwide. JB and WM Industrial Wallmount Enclosures and Accessories

Uninterruptible Power Supplies

Rittal WM Selection Guide. Carbon & Stainless Steel, Disconnect, Slope Top

Cabinet-built single drives, ACS880-07

Make IT easy: Enclosure, power and cooling solutions

Data sheet. Server Rack ( heavy duty rack cabinet ) W:800 = D:1000

INDUSTRIAL THERMAL MANAGEMENT. Filter fans FL-Series

Railway technology solutions

SITESTAR ELECTRONICS CABINET DESCRIPTION

ClimateCab Cabinets and Accessories

VENTILATION. Filter Fans. Example: Waste heat to be removed 500W Temperature difference 20K Air flow required 78m3/hr

Networking: Wall-Mount Cabinets PROTEK Wall-Mount and Double-Hinge Cabinets PROTEK Single-Door Fan and Filter Thermal Packages, UL and NEMA Type 1


Product Information RiCase

Knürr DoubleProRack. 19 Stand-Alone Enclosure

*Discover our other ranges: Select your range of Spacial steel wall-mounting enclosures. Spacial S3DC. Spacial S3X page 5/4. Thalassa PLM page 6/12.

Number of PG holes. 1 x PG 9 (Ø 15.5) 12 x PG 13.5 (Ø 21) 1 x PG 9 (Ø 15.5) /300/400/ Rittal Catalogue 32/Industrial Enclosures

Rittal Automation Systems Assembly Frames

ABB component drives ACS150, 0.5 to 5 Hp

DA-053 Series. Overview. Applications. Features & Benefits. Datasheet. 53lb-in (6 Nm), Non-Spring Return Damper Actuators

Low Profile Insertion Vortex

Standard Product. Polyester powder paint; RAL 7035 textured light gray standard Custom colors available

MTE SERIES RLW. World REACTORS USER MANUAL PART NO. INSTR 030 REL MTE Corporation

Electrical data Nominal voltage AC 24 V, 50/60 Hz DC 24 V

Modifiable TITAN Horizontal Motors Accessories and Modifications

Ri al The System. Faster be er everywhere.

SIRIUS 3RU2 Thermal Overload Relays

Elegant-Pro 19inch free standing rack cabinet W:600 = D:600

Power consumption In operation At rest For wire sizing

VA, VF, and VS Series Direct Mounted Globe Valve Assemblies. Application. Features

IN-LINE MIXED FLOW DUCT FANS MIXVENT-TD Fan Systems

3/2 Introduction. Unequipped Distribution Boards (Flat Pack) 3/6 8GK1 surface-mounting distribution boards

Wallmount EnclosurEs smart DEsign superior protection

ILA2D572TC1F0 integrated drive ILA with servo motor V - DeviceNet - indus connector

din rail mounted active tracking filters with surge protection Product Guide DIN RAIL MOUNTED INDUSTRIAL DC UPS Product Guide

MICRO-CON-X 2-7 NEW PRODUCT BULLETIN C708

19 Server Cabinets SOHO/SMB Networking

Operating Manual (Edition 04/2004) sinamics. Braking Module / Braking Resistor SINAMICS G130

Power consumption In operation At rest For wire sizing. Non-operating temperature

Lowest Cost Louvered Filter Fan Kits. Highest Airflows In The Smallest Packages

Pixus Technologies Catalog

BETA Switching Switches and Light Indicators

VERTIV XTE 401 SERIES. Ordering Guide

Rittal TopTherm chiller

Cabinets Outdoor. Optimal protection from vandalism thanks to a fixing accessible only from within. Easily exchangeable exterior cladding components.

AFGP12B. Features. Efficiency: 12 SEER 80% AFUE. Warranty: 10-year limited compressor 10-year limited heat exchanger 5-year limited components

The Rittal Flex-Block base/plinth system

Power consumption In operation At rest For wire sizing. Actuating force Inhibiting force. Position accuracy ±5% Direction of stroke Motor

Rittal CM Compact System Enclosures

SPECTRACOOL SLIM FIT AIR CONDITIONERS EQUIPMENT PROTECTION

ABB Component Drives ACS150, 0.5 to 5 Hp

ILA1F572PB1F0 integrated drive ILA with servo motor V - CANopen - PCB connector

AMP NETCONNECT 19 NETWORK AND SERVER RACK SYSTEM.

DIN-A-MITE C. SCR Power Controller Delivers Up To 80 Amperes in a Compact Package. TOTAL CUSTOMER SATISFACTION 3 Year Warranty. Features and Benefits

LCU DX Efficient cooling with no loss of space

Overview of types. Technical data. Safety notes

ATyS S - ATyS d S Remotely operated Transfer Switching Equipment from 40 to 125 A

IP65/IP66 ABS/Polycarbonate Screw Lid Boxes

ILE1F661PB1A0 brushless dc motor V - CANopen DS301 interface - L = 122 mm - w/o gearbox

Dimensions WxHxD [mm] Weight [kg]

Control Circuit Protection

IN-LINE DUCT FANS MIXVENT-TD Fan Systems

ES20 Compact Sampling System Stainless Steel Sampling System

INDUSTRIAL POWER SUPPLIES SFL-SERIES

Asynchronous, Low Voltage, Squirrel Cage, Three Phase Electric Motors

ILE2K661PC1A1 brushless dc motor V- EtherNet/IP interface - L = 174 mm- 18:1

Air Cooler Industry AC-LN 8-14 / ACA-LN 8-11 / ACAF-LN 8-11

MODEL G0703HEP HP CYCLONE DUST COLLECTOR MANUAL INSERT (For owner's manual revised May, 2016)

Transcription:

Rittal TopTherm Filter Fans

More pressure. Higher air flow rates. 2

Installation without tools Snap-in mounting for easy installation Simple reversal of the air flow direction by turning the fan module Flexible positioning of the power connection Spring clamp terminals for electrical connection without tools Louvered grille latch for fast filter mat replacement without tools Efficient technology Air throughput from 12-424 cfm (2 to 7 m³/h) New diagonal fan technology for greater pressure stability and constant air flow when installed, even with a contaminated filter mat Reduced installation depth Flow-optimized air routing Extended service life of filter mats and thus longer maintenance intervals UL Type 12 (IP 54) out of the box All fan models available with EMC shielding Air routing Intelligent combination of radial and axial fan technology for most fan models Air flow spreads diagonally from the fan, promoting even air distribution throughout the enclosure Additional environmental protection Hose-proof hoods prevent the entry of water Ratings of up to UL Type 4X are achieved with addition of hood Performance chart new vs. old filter fan design 6 12 18 24 3 36 25 1.2 2 15 1 5 1..8.6.4 1 2 3 4 5 6.2 = Resistance curve Outlet filter 3243.2 = old 5 Hz Filter fan 3326.xxx = new 5 Hz Filter fan 3243.xxx 3

Filter Fan Configuration: Filter fan unit ready for installation, including filter mats, self adhesive mounting template and instructions. Protection Ratings: NEMA 12/IP 54 standard IP 55 with additional fine filter mat NEMA 3R/4/4X/IP 56 with hoseproof hood Property Rights: German Registered Design No. M 93 4 846 Certifications: CE - 35279 UL/cUL - E7683 T1 T2 B1 H1 B2 H2 B = Width T = Depth Air Displacement: 12-39 cfm (2-66 m 3 /h) (Filter Fan and Filter Unit) 3237.1 3237.11 3237.124 3238.1 3238.11 3238.124 (Filter Fan and Filter Unit - EMC) 3237.6 3238.6 Rated operating voltage V, Hz 23, 5/6 115, 5/6 24 (DC) 23, 5/6 115, 5/6 24 (DC) Dimensions inches (mm) B1/H1 5 x 5 (116.5 x 116.5) 6 x 6 (148.5 x 148.5) B2/H2 4 x 4 (92 x 92) 5 x 5 (124 x 124) T1 1 (16) 1 (16) Max. installation depth mm T2 2 (43) 2 (58.5) Air throughput, unimpeded air flow 12/15 cfm (2/25 m 3 /h) 12 cfm (2 m 3 /h) 32/39 cfm (55/66 m 3 /h) 32 cfm (55 m 3 /h) Air throughput with outlet filter including standard filter mat cfm Fan motor 1 x 3237.2: 9/11 cfm (15/18 m 3 /h) Self-starting shaded pole motor DC motor 4 For additional technical information visit www.rittal.us 1 x 3238.2: 25/29 cfm (43/5 m 3 /h) 2 x 3238.2: 27/33 cfm (46/56 m 3 /h) Self-starting shaded pole motor Rated current.65 A/.52 A.12 A/.1 A.125 A.12 A/.11 A.24 A/.22 A.23 A Power consumption 11 W/9 W 3 W 19 W/18 W 5.5 W Pre-fuse 2 A DC motor Noise level 38/43 db (A) 38 db (A) 46/49 db (A) 46 db (A) Operating temperature range F (C ) 5 to 131 F ( 15 to +55 C) Storage temperature range F (C ) -22 to 158 F ( 3 to +7 C) Color RAL 735 outlet filter 3237.2 3238.2 outlet filter EMC 3237.6 3238.6 Accessories PU Filter mats 5 3321.7 3322.7 Filter mats EMC 5 3237.66 3238.66 Fine filter mats 5 3238.55 Hose-proof hood - 34 stainless steel 1 3237.8 1) 3238.8 2) Hose-proof hood - RAL 735 1 3237.85 1) 3238.85 3) Blanking cover 1 3237.2 3238.2 Thermostat 1 311. Digital temperature display 1 3114.2 Hygrostat 1 3118. Speed control 1 312.2 Special voltages and colors available on request. We reserve the right to make technical modifications. 1) UL type 3R 2) UL type 4X 3) UL type 3R/4

Filter Fan Air Displacement: 62-71 cfm (15-12 m 3 /h) (Filter Fan and Filter Unit) 3239.1 3239.11 3239.124 (Filter Fan and Filter Unit - EMC) 3239.6 Rated operating voltage V, Hz 23, 5/6 115, 5/6 24 (DC) B1/H1 8 x 8 (24 x 24) Dimensions inches (mm) B2/H2 7 x 7 (177 x 177) T1 1 (24) Max. installation depth inches (mm) T2 3.5 (9) Air throughput, unimpeded air flow 62/71 cfm (15/12 m 3 /h) 62 cfm (15 m 3 /h) Air throughput with outlet filter including standard filter mat 1 x 3239.2: 51/59 cfm (87/1 m³/h) 2 x 3239.2: 55/64 cfm (93/18 m³/h) 1 x 324.2: 58/65 cfm (98/111 m³/h) Diagonal fan Self-starting shaded pole motor DC motor Rated current.12 A/.11 A.24 A/.22 A.23 A Power consumption 19 W/18 W 5.5 W Pre-fuse 2 A Noise level 46/49 db (A) 46 db (A) Operating temperature range F (C ) -5 to 131 F (-15 to +55 C) Storage temperature range F (C ) -22 to 158 F (-3 to +7 C) Color RAL 735 outlet filter 3239.2 Accessories PU Filter mats 5 3171.1 Filter mats EMC 5 3239.66 Fine filter mats 5 3181.1 Hose-proof hood - 34 stainless steel 1 3239.8 1) Hose-proof hood - RAL 735 1 3239.85 2) Blanking cover 1 3239.2 Thermostat 1 311. Digital temperature display 1 3114.2 Hygrostat 1 3118. Speed control 1 312.2 Special voltages and colors available on request. We reserve the right to make technical modifications. 1) UL type 4X 2) UL type 3R/4 Performance chart 3237.xxx Performance chart 3238.xxx Performance chart 3239.xxx 3 6 9 12 15 6 12 18 24 29 35 41 12 24 35 47 59 71 25.1 7.28 12.48 2 15 1 5.8.6.4.2 6 5 4 3 2 1.24.2.16.12.8.4 1 8 6 4 2.4.32.24.16.8 5 1 15 2 25 1 2 3 4 5 6 7 2 4 6 8 1 12 Performance Curve 1 x 3237.2 Performance Curve 1 x 3238.2 Performance Curve 1 x 3239.2 Performance Curve 2 x 3237.2 Performance Curve 2 x 3238.2 Performance Curve 2 x 3239.2 3237.xxx 5 Hz 3238.xxx 5 Hz 3239.xxx 5 Hz 3237.xxx 6 Hz 3238.xxx 6 Hz 3239.xxx 6 Hz For additional technical information visit www.rittal.us 5

Filter Fan Air Displacement: 16-147 cfm (18-25 m 3 /h) (Filter Fan and Filter Unit) 324.1 324.11 324.124 3241.1 3241.11 3241.124 (Filter Fan and Filter Unit - EMC) 324.6 3241.6 Rated operating voltage V, Hz 23, 5/6 115, 5/6 24 (DC) 23, 5/6 115, 5/6 24 (DC) Dimensions inches (mm) B1/H1 1 x 1 (255 x 255) B2/H2 9 x 9 (224 x 224) T1.98 (25) Max. installation depth inches (mm) T2 4.21 (17) Air throughput, unimpeded air flow Air throughput with outlet filter including standard filter mat 16/94 cfm (18/16 m 3 /h) 16 cfm (18 m 3 /h) 1 x 324.2: 81/71 cfm (138/121 m 3 /h) 2 x 324.2: 97/82 cfm (165/14 m 3 /h) 1 x 3243.2: 97/82 cfm (165/14 m 3 /h) 135/147 cfm (23/25 m 3 /h) 135 cfm (23 m 3 /h) 1 x 324.2: 18/12 cfm (183/25 m 3 /h) 2 x 324.2: 119/135 cfm (23/23 m 3 /h) 1 x 3243.2: 119/135 cfm (23/23 m 3 /h) Diagonal fan Self-starting shaded pole motor DC motor Self-starting shaded pole motor DC motor Rated current.21 A/.19 A.42 A/.38 A.43 A.26 A/.24 A.52 A/.48 A.78 A Power consumption 35 W/34 W 11 W 4 W/42 W 19 W Pre-fuse 2 A 4 A 2 A 4 A 2 A Noise level 51/46 db (A) 51 db (A) 54/56 db (A) 54 db (A) Operating temperature range F (C ) -22 to 131 F ( 3 to +55 C) Storage temperature range F (C ) -22 to 158 F ( 3 to +7 C) Color RAL 735 outlet filter 324.2 Accessories PU Filter mats 5 3172.1 Filter mats EMC 5 324.66 Fine filter mats 5 3182.1 Hose-proof hood - 34 stainless steel 1 324.8 1) Hose-proof hood - RAL 735 1 324.85 2) Blanking cover 1 324.2 Thermostat 1 311. Digital temperature display 1 3114.2 Hygrostat 1 3118. Speed control 1 312.2 Special voltages and colors available on request. We reserve the right to make technical modifications. 1) UL type 4X 2) UL type 3R/4 Performance chart 324.xxx 24 47 71 94 118 1.4 Performance chart 3241.xxx 24 47 71 94 118 141 16.64 8 6 4 2.32.24.16.8 14 12 1 8 6 4 2.56.48.4.32.24.16.8 4 8 12 16 18 4 8 12 16 2 24 Performance Curve 1 x 324.2 Performance Curve 2 x 324.2 Performance Curve 1 x 3241.2 Performance Curve 2 x 3241.2 324.xxx 5 Hz 3241.xxx 5 Hz 324.xxx 6 Hz 3241.xxx 6 Hz 6 For additional technical information visit www.rittal.us

Air Displacement: 323-453 cfm (55-77 m 3 /h) (Filter Fan and Filter Unit) 3243.1 3243.11 3244.1 3244.11 3244.14 (Filter Fan and Filter Unit - EMC) 3243.6 3244.6 Rated operating voltage V, Hz 23, 5/6 115, 5/6 23, 5/6 115, 5/6 4/46, 3~, 5/6 Dimensions inches (mm) B1/H1 13 x 13 (323 x 323) B2/H2 12 x 12 (292 x 292) T1 1 (25) Max. installation depth inches ( mm) T2 4½ (118.5) 5 (13.5) Air throughput, unimpeded air flow 323/353 cfm (55/6 m 3 /h) 412/424 cfm (7/77 m 3 /h) Air throughput with outlet filter including standard filter mat 1 x 3243.2: 259/289 cfm (44/49 m 3 /h) 2 x S243.2: 3/33 cfm (51/56 m 3 /h) 1 x 3243.2: 32/359 cfm (544/61 m 3 /h) 2 x 3243.2: 371/46 cfm (63/69 m 3 /h) Diagonal fan 1~ capacitor motor Rotary current motor Rated current.37 A/.39 A.78 A/.8 A.43 A/.6 A.9 A/1.25 A.17 A/.21 A Power consumption 7 W/87 W 75 W/9 W 95 W/135 W 1 W/145 W 93 W/14 W Pre-fuse 4 A 6 A 4 A 6 A Motor circuit-breaker Noise level 59/61 db (A) 65/66 db (A) Operating temperature range -22 to 131 F ( 3 to +55 C) Storage temperature range -22 to 158 F ( 3 to +7 C) Color RAL 735 outlet filter 3243.2 outlet filter EMC 3243.6 3243.6 Accessories PU Filter mats 5 3173.1 Filter mats EMC 5 3243.66 Fine filter mats 5 3183.1 Hose-proof hood - 34 stainless steel 1 3243.8 1) Hose-proof hood - RAL 735 1 3243.85 2) Blanking cover 1 3243.2 Thermostat 1 311. Digital temperature display 1 3114.2 Hygrostat 1 3118. Speed control 1 312.2 Special voltages and colors available on request. We reserve the right to make technical modifications. 1) UL type 4X 2) UL type 3R/4 Filter Fan Performance chart 3243.xxx 59 118 177 235 294 353 35 1.4 Performance chart 3244.xxx 59 118 177 235 294 353 412 471 4 1.6 3 1.2 35 1.4 25 2 15 1 5 1..8.6.4.2 3 25 2 15 1 5 1.2 1..8.6.4.2 1 2 3 4 5 6 1 2 3 4 5 6 7 8 Performance Curve 1 x 3243.2 Performance Curve 2 x 3243.2 3243.xxx 5 Hz 3243.xxx 6 Hz Performance Curve 1 x 3244.2 Performance Curve 2 x 3244.2 3244.xxx 5 Hz 3244.xxx 6 Hz For additional technical information visit www.rittal.us 7

Accessories Hose-proof hoods For filter fan units/outlet filters When the hose-proof hood is mounted above the filter fan unit or outlet filter a rating of IP 56 (UL 4X) to EN 6 529/1.91 is achieved. Particularly suitable for use in the food industry. Material: Stainless steel Painted steel RAL 735 (light gray) Gasket: silicone, compliant with FDA 21 CFR 177.26 Protection Ratings: In conjunction with the filter fan units/outlet filters, UL Type 3R, 4 or 4X is met. UL and cul recognized UL file: E7683 For Dimensions inches (mm) 3237... 9 x 6 x 2 (23 x 15 x 4) 3238... 1 x 7 x 2 (245 x 176 x 55) 3239... 13 x 9 x 2 (33 x 233 x 55) 324, 15 x 11 x 3 3241... (39 x 282 x 85) 3243, 19 x 14 x 4 3244... (48 x 35 x 11) 1) UL Type 3R 2) UL Type 3R/4 3) UL Type 4X Stainless RAL 735 3237.8 1) 3237.85 1) 3238.8 3) 3238.85 2) 3239.8 3) 3239.85 2) 324.8 3) 324.85 2) 3243.8 3) 3243.85 2) Outlet filters For ventilation by convection, an outlet filter can be installed in the upper and lower sections of the modular enclosure. Material: ABS, material resistance to UL 94-V Color: RAL 735 (light gray) Note: EMC version must use EMC spare filter mat for replacement to ensure EMC shielding Dimensions inches (mm) RAL 735 EMC 5 x 1 (116 x 16) 3237.2 3237.6 6 x 1 (148 x 16) 3238.2 3238.6 8 x 1 (24 x 24) 3239.2 3239.6 1 x 1 (255 x 25) 324.2 324.6 13 x 1 (323 x 25) 3243.2 3243.6 Special colors on request Protection Ratings: UL, cul recognized UL file: E7684 Configuration: Outlet filter including standard filter mat. Replacement filter mats For filter fans Made of random filter non-woven polyester. Temperature resistant up to 212º F (1º C), selfextinguishing, Class F1 according to DIN 53 538. Provides reliable filtration of almost all types of dust down to 1 micron grain size. Material: Synthetic fiber. For filter fan units 3321 and 3237.... 3322 and 3238.... 3323 and 3239.... 3324, 3325, 324 and 3241.... 3326 and 3243.... 3327 and 3244.... H x W x D inches (mm) 4 x 4 x.4 (89 x 89 x 1) 5 x 5 x.5 (12 x 12 x 12) 7 x 7 x.7 (173 x 173 x 17) 9 x 9 x.7 (221 x 221 x 17) 11 x 11 x.7 (289 x 289 x 17) 11 x 11 x.4 (289 x 289 x 1) PU 5 3321.7 5 3322.7 5 3171.1 5 3172.1 5 3173.1 5 3327.7 8 Inch and pound measurements are rounded to the nearest whole number

Accessories Fine filter mats For filter fans Used for extremely fine dust with particle sizes below 1 microns. Made of random filter nonwoven polyester. Temperature resistant up to 212º F (1º C), self-extinguishing, Class F1 according to DIN 53 438. Anticipate higher air resistance when fine filter mats are used. Installation note: Place fine filter mat behind standard filter mat, closer to the fan motor. For filter fan units/ outlet filters H x W x D inches (mm) 3238... 4.7 x 4.7 x.5 (12 x 12 x 12) 3323.../3239 7 x 7 x.5 (173 x 173 x 12) 324.../3241... 9 x 9 x.5 3324.../3325... (221 x 221 x 12) 3243.../3244... 11 x 11 x.5 3326.../3327... (289 x 289 x 12) Material: Synthetic fiber. Clean air side: closed structure. PU 5 3238.55 5 3181.1 5 3182.1 5 3183.1 Replacement filter mats For EMC shielded filter fans Supports the EMC shielding properties of Rittal EMC filter fans. Made of random filter nonwoven polyester and additional copper coating. Temperature resistant up to 212º F (1º C), selfextinguishing, Class F1 according to DIN 53 428. Provides reliable filtration for almost all types of dust down to 1 micron grain size. Material: Copper-nickel coated synthetic fiber. Contaminated side: closed structure For filter fan Filter class according PU to DIN EN 779 3237.6xx, 3237.6 G2 5 3237.66 3238.6xx, 3238.6 G2 5 3238.66 3239.6xx, 3239.6 G3 5 3239.66 324.6xx, 3241.6xx, 324.6 G3 5 324.66 3243.6xx, 3243.6, 3244.6xx, 3245.6xx G3 5 3243.66 Blanking cover If existing mounting cut-outs for fan or outlet filters need to be closed to achieve a higher protection category, the filter mat of the fan or outlet filter can simply be replaced with a blanking cover; welding or other mechanical modification of the enclosure is not necessary. For filter fan 3237.... 3237.2 3238.... 3238.2 3239.... 3239.2 324..../3241.... 324.2 3243..../3244.... 3245.... 3243.2 Material: Plastic Protection category: NEMA 12/IP 54 Speed control Temperature-dependent speed control for Rittal fan and filter units. Dual rated 115/23 V, 5/6 Hz AC for noise reduction and to save energy in partload operation. Technical Specifications: For mounting on 35 mm support rail to DIN EN 5 22 Rated operating voltage: 23 V (AC)/115 V (AC) Setting range: +68 to +131 F (+2 to +55 C) Phase cross-over controller PU 1 312.2 Maximum fan output: 3 W Dimensions inches (mm): 4.1 x 3.5 x 2.4 (15 x 91 x 6) Protection Rating: UL file: E23342 For additional technical information visit www.rittal.us 9

Accessories Enclosure thermostat The enclosure thermostat is particularly suitable to control filter fans but can also be used to signal and monitor the temperature inside an enclosure. Technical Specifications: Bi-metal sensor acts as a temperature-sensitive element with thermal feedback Contact: 1 pole, spring loaded switch elemement Permissible contact load: Category 5 3 (heating) AC 1 (4) 1) A, DC = 3 W Category 5 4 (cooling) AC 5 (4) 1) A, DC = 3 W 1) = Inductive load at cos j =.6 Setting range 41 to 14 F (+5 to +6 C) Weight approximately 4 oz (15 grams) Dimensions 3 x 3 x 1" (71 x 71 x 33 mm) Switching difference approximately 1 K ±.8 K A broad voltage spectrum, just one model covers 24 to 23 V. Time-saving connection technique using a terminal strip with a screw connection from the outside. Voltage 23/115/6/48/24 V AC 6/48/24 V DC 311. Flexible mounting on a vertical or horizontal 1" (35 mm) support rail to EN 5 22, and snap fastening in the TS/ES enclosure section using the supplied adaptor. Protection Ratings: UL, cul recognized,ce,vde UL file: E1744 Hygrostat The hygrostat switches on the fan when a preset relative humidity level in the enclosure is exceeded. This maintains the relative humidity in the enclosure above the dew point and prevents condensation in the cabinet or on components. Technical Specifications: Contact population: Single-pole change-over contact as a quick-break contact Permissible contact load: AC ~ 5 (.2) 1) A DC = maximum 2 W 1) = Inductive load at cos j =.6 Setting range 5 1% relative humidity Weight approximately 4 oz (1 g) Dimensions 3 x 3 x 1" (71 x 71 x 33.5 mm) Switching difference approximately 4% A broad voltage range, only one model covers 24 to 23 V. Time-saving connection technique using a terminal strip with a screw connection from the outside. Flexible mounting on a vertical or horizontal 1" (35 mm) support rail to EN 5 22, and snap fastening in the TS/ES enclosure section using the supplied adaptor. Voltage 24-23 V (AC/DC) 3118. 1 Inch and pound measurements are rounded to the nearest whole number

Filter Fan Cross Over Old vs. New Design Conversion Made Easy As with all products, Rittal continuously implements design improvements and new technology. Our entire line of filter fans has been updated to a new design and, because they have been engineered to fit the same cut-outs as our prior fan design, they are easily integrated into your application. The table below makes it easy to transition from the prior design to the new one. Air throughput unimpeded airflow Cut-out dimensions inches (mm) 24 V 23 V 115 V 4 V/46 V EMC fan and filter unit, 23 V Outlet filter EMC outlet filter Hose-proof hood - carbon Hose-proof hood - stainless Blanking cover Standard filter mat (IP 54) EMC filter mat Fine filter mat (IP 55) 12/15 cfm (2/25 m 3 /h) 32/39 cfm (55/66 m 3 /h) 62/71 cfm (15/12 m 3 /h) 16/94 cfm (18/16 m 3 /h) 135/147 cfm (23/25 m 3 /h) 323/353 cfm (55/6 m 3 /h) 4 x 4 (92 x 92) 5 x 5 (124 x 124) 7 x 7 (177 x 177) 9 x 9 (224 x 224) 12 x 12 (292 x 292) 412/424 cfm (7/77 m 3 /h) new 3237.124 3238.124 3239.124 324.124 3241.124 old 3321.27 3322.27 3323.27 3324.27 3325.27 new 3237.1 3238.1 3239.1 324.1 3241.1 3243.1 3244.1 old 3321.17 3322.17 3323.17 3324.17 3325.17 3326.17 3327.17 new 3237.11 3238.11 3239.11 324.11 3241.11 3243.11 3244.11 old 3321.117 3322.117 3323.117 3324.117 3325.117 3326.117 3327.117 new 3244.14 old 3327.147 new 3237.6 3238.6 3239.6 324.6 3241.6 3243.6 3244.6 old 3321.67 3322.67 3323.67 3324.67 3325.67 3326.67 3327.67 new 3237.2 3238.2 3239.2 324.2 3243.2 old 3321.27 3322.27 3323.27 3325.27 3326.27 new 3237.6 3238.6 3239.6 324.6 3243.6 old 3321.267 3322.267 3323.267 3325.267 3326.267 new 3337.85 3238.85 3239.85 324.85 3243.85 old 3321.835 3322.835 3323.835 3324.835 3326.835 new 3237.8 3238.8 3239.8 324.8 3243.8 old 3321.8 3322.8 3323.8 3324.8 3326.8 new 3237.2 3238.2 3239.2 324.2 3243.2 old new 3321.7 3322.7 3171.1 3172.1 3173.1 old 3321.7 3322.7 3171.1 3172.1 3173.1 3327.7 new 3237.66 3238.66 3239.66 324.66 3243.66 old new 3238.55 3181.1 3182.1 3183.1 old 3181.1 3182.1 3183.1 For additional technical information visit www.rittal.us 11

Enclosures Power Distribution Climate Control IT Infrastructure Software & Services The Rittal Corporation is the U.S. subsidiary of Rittal GmbH & Co. KG and manufactures the world s leading industrial and IT enclosures, racks and accessories, including climate control and power management systems for industrial, data center, outdoor and hybrid applications. For more information about Rittal and its products, please visit www.rittal.us or call 1-8-477-4. 7/11 US195 Rittal Corporation 1 Rittal Place Urbana Ohio 4378 USA Woodfield Corporate Center 425 North Martingale Road, Suite 4 Schaumburg Illinois 6173 USA Phone: 937-399-5 Fax: 8-477-43 Toll-free: 8-477-4 Email: rittal@rittal.us Online: www.rittal.us 12 For additional technical information visit www.rittal.us