INSTRUCTION MANUAL. Flow sensor FUS20 series HIR

Similar documents
INSTRUCTION MANUAL SMALL SIZE FLOW SENSOR RAPIFLOWR

Small size flow sensor

Flow Sensor FUS20. Suction lift verification of small workpiece, which is hard to detect bypressure sensor, or flow management is possible.

Compact Flow Rate Sensor. RAPIFLOW FSM3 Series Resin Body Type. Diversified High Performance. High performance. User-friendly. Compatible CC-1235A 1

Related vacuum products

ITVX Series. Stepless control of air pressure proportional to an electrical signal. Supply pressure: 5.0 MPa

Series ZSE30/ISE30. High Precision, 2-color Display Digital Pressure Switch. With One-touch fittings are newly introduced. PSE

2-Color Display High-Precision Digital Pressure Switch

Digital Flow Switch (Integrated display type)

2-Color Display High-Precision Digital Pressure Switch

Operating Instructions Vaccon VDS-1000 Solid State Combination Vacuum Switch/Sensor w/ Digital Display

Digital Flow Switch (Integrated display type)

2-Color Display High-Precision Digital Pressure Switch Series ZSE40A(F)/ISE40A

Flow sensor for compressed air

Vacuum pump system type

2-Color Display Digital Pressure Switch. Rated Pressure Metal Body Type (ISE75H) 2-color digital. Functions

Flow sensor for compressed air

Small size flow controller

2-Color Display Digital Pressure Switch. NPN/PNP open collector 2 outputs added. Cut-to-zero display function added. Rated Pressure Metal Body Type

Series 10-ZSE40A(F)/10-ISE40A

3-step setting. 2-Color Display High-Precision Digital Pressure Switch. Series ZSE30A(F)/ISE30A. Added vacuum range.

Series ZSE30/ISE30. High Precision, 2-color Display Digital Pressure Switch 25 M ISE30 01 ZSE M. How to Order. For positive pressure

Sensor specifications Model no.

Low Differential Pressure Sensor ±1% F.S.

DPS280 / DVS280 Series


Digital Flow Switch (Remote type monitor unit)

2-Color Display Digital Pressure Switch. Rated Pressure Metal Body Type. MPa MPa (ISE75H) 2-color digital. Functions

10 switches simultaneously. The settings of the master sensor (source of copy) can be copied to the slave sensors. Reducing setting labor

Flowsensor for compressed air

2-Color Display Digital Pressure Switch

Clean Air Module. Digital flow switch Regulator ON/OFF valve Restrictor Filter

Model Pressure range ON/OFF output Linear output

* E8MS-N1 is only 1-channel pressure sensor controller. E80-C2 can be used. For more details, please refer to E80 catalogue.

Digital pressure switch for energy-saving control ejector

Digital Flow Switch (Sensor Part) Operation Manual

FLOW METERS. 90 left. 90 right. Sensor. Rotary display. Models. FA Series

Unit specifications. Nil. Option 1. Power supply/output connection cable. Option 2

2-Color Display Digital Pressure Switch

2-colour display. Digital Pressure Switch. Stainless diaphragm Oil-free (Single-layer diaphragm structure) IP65 compliant

Construction diagram Semiconductor transducer Silicone oil. Stainless steel SUS316 pressure port Hastelloy C diaphragm.

ISE6B. Series ZSE6B. Digital Pressure Switch. With Backlight. (For vacuum) (For positive pressure) For General Purpose Fluids

Pressure Switch with Super slim LED Display

Pressure Transmitter

Helical Flow. HF-GC/GP Series

DPC-100 Series INSTRUCTION MANUAL WIRING I/O CIRCUIT DIAGRAMS PART DESCRIPTION

Digital Flow Switch PFM7##

Model Pressure range ON/OFF output Linear output

9.8 mm. Digital Pressure Switch. 3-step setting. RoHScompliant. Series ZSE10(F)/ISE10. Vertical mounting space reduced to approx.! Reduced in depth!

ITVH Series. 3.0 MPa Maximum Supply Pressure High Pressure Electro-Pneumatic Regulator. 3.0 MPa 0.2 to 2.0 MPa. 3 W or less L /min (ANR)*

PG-30 PRESSURE GAUGES P G R - N FEATURES MODEL NUMBER DESIGNATION

2-Color Display Digital Flow Switch

Differential Pressure Transmitter

INSTRUCTION MANUAL DIGITAL

Pressure sensor with built-in amplification and temperature compensation circuit

Differential Pressure Sensor

2-Color Display Digital Pressure Switch

Digital display Pressure range ON/OFF output Linear output Model

ION JET NOZZLE NIH-55

Head-separated Digital Pressure Sensor DP5 SERIES DPH SERIES

VSG Series Features Descriptions VSG VSG VSG Descriptions Supply valve Descriptions Vacuum filter

SERIES LED Display Digital Pressure Sensor. Clearly Visible LED Display with 3 1 /2 Digits

WaterMAG. Electromagnetic Flowmeter for Water Applications. Model MCB10A OVERVIEW APPLICATIONS FEATURES. No. SS2-MCB

Set value (Threshold value) Bottom value. *2 Further reduced by approx. 60% in power-saving mode (For 20 series)

Pressure Gauge. Fluid admitted Pressure indication range Accuracy Service temperature range Cap. Resin body GPC (1)

Super fast 1 ms Convenient intermediate cable with connector A total of 10 head variations

Pneumatic Drive Type Drill Bit Breakage Detection Sensor. DFM3 Series. The World's First!! Pneumatic-Drive Type. Catalog / Instruction Manual US.PAT.

Doc. No. IZ -OML0002-B OPERATION MANUAL. Ionizer PRODUCT NAME:

POWER REGULATOR LD -40PSU

High-frequency AC Method. panasonic-electric-works.net/sunx

10 PSE53 0 M5. Port size. M5 x 0.8 ø6 reducer 1/4-inch reducer. the cable at the time of shipment. 10-PSE to -101 kpa

The Multivariable Air Flow Meter

Series PSE560 Pressure Sensor For General Fluids... 90

Series PSE100. Controller PSE10. How to Order. Controller Specifications Option. Output specifications. Mounting

SERIES LED Display Digital Pressure Sensor. Clearly Visible LED Display with 3 1 /2 Digits

Pattern Air Control Kit (PACK)

Digital Pressure Switch

Vacuum Switch with LED display

PG-30 PRESSURE GAUGES P G R - N MODEL NUMBER DESIGNATION

Simple Pressure Level Setting. The threshold level is able to adjust simply. Just set the pointer suitable for the displayed pressure level.

Digital Flow Switch (Remote type sensor unit)

DP5/DPH. Head Separated Digital Pressure Sensor. 1/1000 Second High-Speed Response. The advantage of the fastest response in the industry SERIES

Electro-Pneumatic Regulator Electronic Vacuum Regulator. Series Model Set pressure range Port size to 0.1MPa to 0.5MPa to 0.

Series ITV0000. Compact Electro-pneumatic Regulator ITV N. IITV00 02 n. How to Order F.R.L. AV AU AF AR IR VEX AMR ITV IC VBA VE VY1 G PPA AL

Digital Flow Switch for Deionized Water and Chemicals Body and sensor New PFA Tube Super PFA

The Multivariable Air Flow Meter

LCD Readout Digital Pressure Switch

Electronic pressure switch for air

Digital Pressure Switch

Conventional specification. External Pilot air specification 0 ~ 0.7. Compact, yet keeps large capacity.» Limited space can be utilized.

CBM-105FN/FP Circuit Board

Electro-Pneumatic Regulator / Electronic Vacuum Regulator

Series ITV. Electro-pneumatic Regulator Electronic Vacuum Regulator F.R.L. AV AU AF AR IR VEX AMR ITV IC VBA VE VY1 G PPA AL

Three types of flow range. 0.4 to 4 L/min (PF2D504) 1.8 to 20 L/min (PF2D520) 4.0 to 40 L/min (PF2D540) Swept flow characteristics (reference)

TOWA SEIDEN INDUSTRIAL CO., LTD.

Micro-differential Pressure High-precision Digital Pressure Sensor For Gas DP-M SERIES

No.EX -OME0016-A PRODUCT NAME. SI unit. MODEL / Series / Product Number EX140-SDN1

OPERATING INSTRUCTION

Read and understand this manual for safely usage.

Cat. No. I526-E1-1 USER S MANUAL 3G3IV-PLKEB2 /4. Braking Resistor Units 3G3IV-PCDBR2 B/4 B. Braking Units

Transcription:

HIR0057-00 INSTRUCTI MANUAL sensor FUS0 series P l e a s e b e s u r e t o r e a d t h i s User's Manual before using the sensor. E specially, be sure to read safety instructions carefully. P lease keep this manual handy w i t h c a r e s o y o u c a n r e f e r t o i t whenever necessary. s t e d i t i o n

Warning and caution in order to ensure safety Display explanations Danger Failure to heed the warning of apparent danger may result in death or serious injuries. Warning Failure to heed the warning of conditionally dangerous situations may result in death or serious injuries. Caution Failure to heed the warning of conditionally dangerous situations may result in minor or not too serious injuries or damage to properties Fluid medium and usage environment A flammable fluid must not be used. Danger Please do not use the product in flammable gas environment. Since the product is not explosion-proof, explosion or fire may be caused. Warning For wiring, turn off the power supply first. Please discharge static electricity built in body, tool and equipment before and during work. Use a wire with elasticity as wire for robot connection in the movable part. This product and wiring must be installed as far away as possible from noise source such as strong electric line, etc. Please do not short-circuit a load, or causing damage or burn. Please do not conduct improper wire connection, which result in burst or damage of the sensor Please make sure to put connector cover on after connecting connector. Please do not stress a cable drawing position directly or connector. Warning Since it is not conformed to the Measurement Law, please do not use the product for the commercial purpose. Please do not use the product with other than applicable fluid medium, or the accuracy can not be guaranteed. And, Please do not use the product in an environment containing corrosive gas, flammable gas and oxygen. Please install a filter, an air dryer and an oil mist filter (micro alescer) onto the primary side (upstream) of the sensor since the compressed air from the compressor contains drain (water, oil oxide and foreign material, etc) When using this product with suction lift verification, etc., please always install an air filter onto the upstream of suction side to prevent suction of foreign materials. Please do not use the product in an environment containing corrosive gas such as sulfurous acid gas, or etc. Please use the product within the ambient / fluid temperature ranges 0 to 50 C. Even in the specified temperature range, please do not use the product where ambient / fluid temperatures change suddenly, and form dew condensations Please use the product in accordance with specifications. If used out of the maximum working pressure and working flow range, the product may result in failures. The protective structure of this product is equivalent to IP40. Please do not install the product where moisture, salt, dust or swarf is contained, or where pressurized, or depressurized, neither. The flow rate of this product is measured by mass flow where mass flow is Caution converted to volumetric flow at 0 C and atmospheric pressure (0kpa). Piping and installation Caution It must be piped, while matching the flow direction and direction specified on the body. When the sensor is installed to the piping, avoid excessive driving torque or loading torque: Please flash the pipe by air blow to remove foreign substances before piping. Prevent the entrance of seal tape or adhesive into the piping when conduction pluming. If a quick-fitting is used, the tube must be inserted certainly. Please pulls the tube to check that it will not come out. The flow display uses liquid crystal. It may be hard to see by an angle. This product can be installed with any orientation; vertical, horizontal, right or left. Piping must be done prior to panel installation. Usage and Maintenance t Warning Caution Output accuracy is affected by self-heating caused by energizing other than temperature characteristics. At the time of usage, stand-by time (over 5 minutes after energization) must be provided. For self-diagnosis, this product does not conduct flow rate detecting switch operation for about 4 seconds immediately after energized. Please make a control circuit and programs to ignore signals for about 4 seconds after energized. Please install fail-safe devise for the applications where the malfunction of the sensor leads to major accident. When changing set points of the output, please stop the equipment, then change the set points, or an accident may occur. Disassembly and modification must not be done or causing a failure. When an error occurs during operation, please turn off power supply immediately, and terminate the operation, and contact to the sales office. Solvent/alcohol/cleaner, etc., must not be used to remove contamination, etc., or causing a resin to be corroded. Please wipe with diluted neutral detergent by tightly squeezed waste cloth, etc. Even if exceeding the flow rate range, analog output will be provided. "Hi" or "Lo" will be displayed. However, please be noticed in advance that accuracy is not guaranteed. Please do not punch sensor display. It may cause a failure. Display/operating section names and functions Main display (green/red) Display set value and flow rate Display color can be changed. rate unit display (green) Display flow rate unit Sub display (green/red) Display flow direction and operating status Display color can be changed Output (OUT) display (green) Illuminate when CH output is Flash when over current is detected Output (OUT) display (green) Illuminate when CH output is Flash when over current is detected. (UP) key Sequentially displays the CH data when the flow rate is displayed. Display the maximum value during peak hold operation When selecting a mode, determines the mode When setting each data, using count up numbers, etc. Wiring Danger Power supply voltage and outputs must be used with the specified voltage. Applying more than specified voltage may cause malfunction, damage of sensor, electric shock or fire. Please do not apply load more than the rated output. Damage of the output or fire may be caused. MODE Key Use to enter each setting mode Use to return to the flow display Use to turn off peak hold operation (DOWN)key Sequentially displays the CH data when the flow rate is displayed. Display the minimum value during peak hold operation When setting each data, using count down numbers, etc.

Piping and installation It must be piped, while matching the flow direction and direction specified on the body direction Please flash the pipe to remove foreign substances and swarf, etc., in inside of pipe before piping. Prevent the entrance of seal tape or adhesive into the piping when conduction pluming. If a quick-fitting is used, the tube must be inserted certainly. Please pulls the tube to check that it will not come out. This product can be installed with any orientation; vertical, horizontal, right or left. Tightening torque of fixing screw is 0.5N.m. <Vertical (female thread on the bottom)> <Bracket installation> <Horizontal (through hole)> <Panel mount installation> 3Wiring Power supply voltage and outputs must be used with the specified voltage. Applying more than specified voltage may cause malfunction, damage of sensor, electric shock or fire. Please do not apply load more than the rated output. Damage of the output or fire may be caused. For wiring, turn off the power supply first. Please discharge static electricity built in body, tool and equipment before and during work. Use a wire with elasticity as wire for robot connection in the movable part. This product and wiring must be installed as far away as possible from noise source such as strong electric line, etc. Please take other countermeasures for a surge on the power supply line. Please do not short-circuit a load, or causing damage or burn. Please do not conduct improper wire connection, which result in burst or damage of the sensor. Connector cover Please make sure to put connector cover on after connecting connector. Please do not stress a cable drawing position directly or connector. Example of internal circuit and load connection NPN output type Model:FUS0-N - < CH function selected switch output> (brown)power+ Main circuit R 3 4 5 (black)ch SW output (white)ch SW output (gray)analog output (blue)power- + - Model no. of bracket :FUS0-B <Panel installation > 3 Install panel stopper on the reverse side of panel (by hitching to the cover stopper) and fix by the screws. Install panel holder cover on the upper side of panel. Please refer to appearance dimension for panel cut size. Panel Panel holder cover Panel stopper Sensor 4 5 Caution: Install panel holder from the reverse side of panel. Panel holder Screws Push panel holder until the sensor is firmly fixed and connect the connector. Without needle valve type Panel mount kit: FUS0-P Built-in needle valve type Panel mount kit: FUS0-PN Install the sensor on the reverse side of panel. Make sure to conduct piping before installing panel mount so as not to apply excessive force to panel mount parts.. Tightening torque of panel stopper is 0.06N m. <CH function selected external input> (brown)power+ Main circuit PNP output type Model :FUS0-P - <CH function selected switch output> (brown)power+ Main circuit (black)ch SW output (white)ch SW output ((gray)analog output ((blue)power- <CH function selected external input> (brown)power+ Main circuit R R R 3 4 5 3 4 5 3 4 5 (black)ch SW output ((white)ch SW output ((gray)analog output (blue)power- ((gray)analog output ((blue)power- (black)ch SW output (white)ch SW output + - + - + - 3 4 5 (FUS0 side) Pin No. Line color Content Brown Power supply (DC to 4V, DC 4V) Black CH(Switch output : max50ma) 3 White CH(Switch output : max50ma or External input) 4 Gray Analog voltage output : DC to 5V Connected load impedance 50kΩ and over) Analog current output : DC 4 to 0mA Connected load impedance 300Ω or less) 5 Blue 0V (GND) Analog output voltage output type R:aboutkΩ Current output type R:about00Ω

-3-4Function Some functions and settings are completed when the normal flow is displayed, and some after entering setting mode. The setting mode is divided into standard setting mode and detailed setting mode based on the frequency of use. <Normal mode> Item Description rate display Instantaneous flow rate is displayed. Integrating function Integrated flow rate is displayed. Peak hold function Maximum and minimum flow rate values during the specified period can be read. Setpoint Switch data (setpoint value and operation mode) are displayed to verification check. Key lock Setting changes are disabled to prevent incorrect operations. Error display function The error state is displayed. <Standard setting mode> Item Description Switch output Having pieces of switch output, 7 operation patterns and stop of operation can be set. Forcible output Switch output is turned on forcibly to check wiring connection and function initial operation of input unit. 0 point adjustment Deviation of the display from o is corrected. <Detailed setting mode> Item Description direction Only bi-directional type, flow direction can be switched. selection CH function Sets the CH function. selection Selects Switch output, External input of auto reference, or External input of integrated reset. Auto reference function Response time setting Display speed selection Sub-display selection Displayed color selection Hysteresis fixed value selection rate unit selection When CH function selected external input of auto reference, setting value of switch output can be taken by external input or key operation. Sets the response time. The response time can be selected from 0ms to 80ms. Change the speed of the displayed. Change the indication of the sub-display. Selects direction, rate unit, or Working fluid. Displayed color can be changed. Sets hysteresis of the window operation mode and the auto reference mode. (8 steps) rate unit can be changed. Standard condition (ANR): Converted to volumetric flow at 0 C and atmospheric pressure (0kPa). Reference condition (NOR): Converted to volumetric flow at 0 C and atmospheric pressure (0kPa).(calculation value) Eco mode setting Current consumption can be lowered. When the product is left for min. without any operation, it s shift to eco mode. Reset setting Return to default settings (factory settings) 5Setting method 5-.Normal mode <Changing Instantaneous flow rate display and integrated flow display> <Instantaneous flow rate> Display unit selection Instantaneous flow rate display (Unit : m ) Press M key once when Instantaneous flow (Integrated flow) is displayed. Display unit selection appears and the display blinks. Press or key to choose display and decide display by pressing M key once. Integrated flow display (Unit :ml L) ml <Peak hold function > <Instantaneous flow rate display> Press and M simultaneously Peak hold display Being held down <Peak value displayed> <Set point verification method> Note) This function is canceled when auto reference mode by external input is used. <Key lock function > Key lock <Instantaneous flow rate display (key unlock)> Being held down Reset peak hold function. <Instantaneous flow rate display> CH data display Being held down When CH selected window operation[] < setting value > Displays in turn Operation wave form < setting value > Separate Press M key and simultaneously when Instantaneous flow (Integrated flow) is displayed. Peak hold appears on the display. Peak value is displayed while key is pressed Bottom value is displayed while key is pressed. Peak hold is canceled when M key is pressed. <Bottom value displayed> When Instantaneous flow (Integrated flow) is displayed, CH setting value is displayed while key is displayed. CH setting value is displayed while key is pressed. Being held down CH data display When CH selected external input of integrated reset. Separate Press key and key simultaneously and press M key for one second at the same time, [Loc] appears and enters key lock condition. Press and M simultaneously for sec. <Instantaneous flow rate display (key lock)> Key unlock At key lock condition, press and M <Instantaneous flow rate display (key lock)> simultaneously for 3 seconds, [unl] appears and key lock is canceled. (confirmed) <Integrated flow display> ml Press simultaneously for sec. Integration reset Integration is reset when and keysarehelddownforsec. ml Press and M simultaneously for 3sec. <Instantaneous flow rate display (key unlock)> Note: Integration is reset with the external input. See auto reference function. Note: Integration is also reset or Integrating function display setting is keeping when power is turned. Note: Keys are unlocked when the controller is shipped. Lock keys if necessary. The key lock/unlock state is held even if power is turned. While key lock, all the operations are not accepted excluding the key lock release operation. While key lock, If the key is operated, it becomes a Loc display.

5-.Standard setting mode <How to enter to standard setting mode> <Instantaneous flow rate display> Press for 3 sec.. (The display blinks.) Press M key for 3 seconds when Instantaneous flow is displayed. Standard setting mode appears. Press M key to change mode and confirm mode by pressing key. <Setting of switch output function> Switch output CH operation mode change Choose CHoperation mode. Press or key and choose desirable operation mode and press M key to confirm. <Switch output > <Window operation []> <Window operation []> <Switch output> (Confirmed) To switch output <Integrated pulse> <Hysteresis operation []> <Forcible output function> (Confirmed) <Integrated output []> <Integrated output []> <Hysteresis operation []> To forcible output <0 point adjustment> (Confirmed) (Confirmed) To 0 point adjustment CH / data setting (window operation is chosen) < value set> < value set> <Switch output> Having pieces of switch output, 7 operation patterns and stop of operation can be set. Operation pattern Description Operation waveform Window operation[] The switch turns (Range inside ) when the level is within the designated flow rate range. Histeresis set in fixed value separately Window operation[] (Range outside ) Hysteresis operation[] ( rate small side ) Hysteresis operation[] ( rate large side ) Integrated output[] ( when higher than set integration) Integrated output[] ( when higher than set integration) The switch turns when the level is not within the designated flow rate range. when lower than set point. Hysteresis can be arbitrarily set. when higher than set point. Hysteresis can be arbitrarily set. The switch turns at the set integrated flow. The switch turns at the set integrated flow. Lower limit Upper limit Histeresis set in fixed value separately Lower limit Lower limit Lower limit Set point Set point Upper limit Upper limit Upper limit Integ.. flow Integ. flow Count UP Count down < Switch output forcible mode> Forcible output <0 point adjustment mode> 0 point adjustment Set switch / data. Press key to count UP and key for count DOWN and press M key for confirmation.. Lower limit cannot be set beyond upper limit. Please set upper limit first. When flow direction is one way, the minus setting cannot be conducted.. (CH confirmed) CH operation mode change (Set same as CH) (Operation mode confirmed ) CH / data setting (Set same as CH) (CH confirmed) Switch is forcibly set in mode. CH is on while key is pressed. CH is on while key is pressed.(ch is canceled when e by external input is used. To instantaneous flow set Press simultaneously (adjusted value reading) Adjustment value display Integrated pulse The integrated pulse is output during integration. See specifications for details on the pulse output rate. Switch output Switch output Note: Hysteresis is provided on upper and lower limit of window operation automatically. The hysteresis can be fixed in 8 steps. Refer to <Hysteresis fixed value selection> in <Detailed setting mode>. 40msec Pulse rate Integ. flow -4- To instantaneous flow (confirm) Adjust 0 point gap.. (Be sure to make flow rate 0 and take in offset value.) Press and at the same time and take in set value and confirm by M key. Note ) If the gap is more than ± 0%, [E 0] appears and offset value is cleared. Offset value is arithmetic value. Therefore, it differs from actual flow rate value.

5-3.Detailed setting mode <How to enter to detailed setting mode> <Instantaneous flow rate display> At instantaneous flow rate display, press M key for 8 sec. to enter to detailed setting mode. Press M key to change mode and press key to confirm. Press for 8 sec. (Indication blinks Press continuously while CH display) < direction selection(bi- directional type)> (Confirmed) <Auto reference function> (Confirmed) To flow direction To auto reference (Confirmed) <Response time setting> To response time (Confirmed) <Display speed selection> To display speed (Confirmed) <Sub-display selection> < direction selection (only bi-directional type)> Only bi-directional type, flow direction can be switched. direction LCD indication Analog output feature When reverse flow, - is <Bi-directional> (V) (ma) indicated 5 0 <One-direction (Forward)> <One-direction (Reverse)> Setting of flow direction direction Setting of flow direction The arrow changes according to flow direction The arrow indication for forward direction The arrow indication for reverse direction Analog output Analog output Analog output 3 4 -F.S. 0 F.S. () (V) (ma) 5 0 3 4 0 F.S. () (V) (ma) 5 0 3 4 0 F.S. () Determine flow direction.. Press key or key to select flow direction. < One-direction (Forward) <One-direction (Reverse)> <Bi-direction> To sub-display (Confirmed) <Displayed color selection> To displayed color (Confirmed) <Hysteresis fixed value selection> To hysteresis fixed value (Confirmed) < rate unit selection> To flow rate unit (Confirmed) <Eco mode setting> To eco mode (Confirmed) <Reset setting> <Model number display> (Confirmed) To reset To model number display -5- (Confirmed) To instantaneous flow rate Note )Note: When flow direction is changed, other setting value as follow is cleared. Please make sure to set flow direction first. Switch setting/zero adjusting value/integrated flow value/external input mode <Auto reference function> When CH function selected external input of auto reference, setting value of switch output can be taken by external input or key operation.the setting value can be automatically changed when workpiece is changed for example. The set point takes the flow rate when external input is turned on (or key operation). When auto reference is executed, the switch setting of CH becomes invalid. Input point point points Operation Description mode More than input when higher than input value point. Set-point=input point More than input when higher than input value point. Set-point=input point More than when higher than centre center value of value of two input points two points Set-point= (input point+input point)/ More than center value Of two pints Within two points value Within two points value when higher than centre value of two input points Set-point= (input point+input point)/ when flow rate level is within two input points. Setpoint=input point Setpoint=input point when flow rate level is within two input points. Setpoint=input point Setpoint=input point Operation waveform Input point Input point Input point Input point Input point Input pioint Input point Input point F.low Input point Input pioint

Setting of auto reference Auto reference Setting of CH function <Auto reference> Press or key to select CH function. <Switch output> < External input of integrated reset> < Setting of response time> Response time Setting of response time (confirmed) Press or key to select response time. Indication Response time SP 50msec SP 80msec SP 3 0msec SP 4 00msec SP 5 400msec SP 6 800msec SP 7 500msec Note ) The response time is only reference use. The actual response time differs by the piping. Condition. (confirmed) (confirmed) (confirmed) To setting of CH switch output Reference method selection (Key operation / External input) <Key operation> <External input> <Setting of display speed> Display speed Setting of display speed Press or key to select display speed. <50msec> <500msec> <000msec> (confirmed) Input point selection < point > < points> (confirmed) (confirmed) Operation mode selection (-point) <more than input value > <more than input value > (confirmed) Operation mode selection (-points) <More than center value of two points > <More than center value of two points > > <Setting of sub-display> Sub-display Setting of sub-display Press or key to select sub-display. < direction> < rate unit> <Working fluid> (confirmed) <Within two points value <Within two points value To instantaneous flow rate (confirmed) How to take set point by key operation point input : The set point takes the flow rate when press key for sec. point input : The upper limit takes the flow rate when press key for sec. The lower limit takes the flow rate when press key for sec. After taking, the set point is displayed. How to take set point by external input point input : The set point takes the flow rate when external input is turned on (keep approx. 40msec.). points input : The set point takes the flow rate when external input is turned on (keep approx. 40msec.). The big and small relations between latest two points are compared. The upper limit and lower limit are distinguished automatically. (e.g.) Input point(m) Lower limit(m) Upper limit(m) Initial value 0 0 st 3 0 3 nd 34 3 34 3rd 45 45 34 4th 345 45 345 5th 456 345 456 The initial point is zero for upper and lower limit. After taking, the set point is displayed. Also the pulse(/) is output from CH for the taking confirmation. The set point value is cleared if power is turned. <Setting of display color> Display color Setting of display color <Red when > (Green when ) <Green when > (Red when ) (confirmed) Main display shows the state of CH. Depending on CH, CH switch condition, the display color of main display and sub-display changes. Press or key to select display color. <Always red> Sub display shows the state of CH <Always Green> -6-

<Hysteresis fixed value selection> Hysteresis fixed value Hysteresis fixed value selection When window operation or auto reference is selected. Press or key to select hysteresis fixed value. <Model number display> Model number display Conduct model number display and setting value display Model number display <Model number> <Full scale flow rate> < rate unit & flow direction> <Approx. %F.S.> <Approx. %F.S> <Approx. 8%F.S.> <Working fluid> Ai : Air,N <Switch output> N : NPN output P : PNP output <0 point adjustment value>. (Confiremd) <Setting of flow rate unit> rate unit Press or key to select flow rate unit. Setting of flow rate unit <ANR:0 atmospheric pressure conversion> <NOR:0 atmospheric pressure conversion>. (Confiremd) <Setting of Eco mode> Eco mode Setting of Eco mode <Eco mode >. (Confirmed) Approx. minute later < Reset to the initial setting> Note: NOR display is calculation value. At factory shipment, the adjustment and inspection is done at ANR condition. Press or key to select eco mode. <Eco mode > Eco mode : If any key is not carried out for approx. min., the display is turned off and L appears. Press any key to show the indication. Reset Reset setting <Reset is not executed>. (Confirmed) Setting at shipping out of factory Item Switch out put Zero adjustment value Integrating flow rate value direction (bi-directional type only) Auto reference (CH setting) Response time Display speed Sub-display Displayed color Hysteresis rate unit Eco mode Press or key to select reset setting. <Reset is executed> Setting at shipping out of factory Zero Zero Bi-directional type: Bi-direction One-directional type: One-direction Switch output SP(50msec) 50msec direction display Red when. Green when. %FS ANR L 6Troubleshooting <Error displays and corrective action> Error indication Cause Corrective action Switch output indicator is blinking (No switch output) <Troubleshooting> The flow rate is not reset within the rating at zero adjusting An error occurred during EEPROM reading or writing. An error occurred during memory reading or writing. Reading exceeds the upper limit of detection range. Sensor chip is broken Reading exceeds the lower limit of detection range. Sensor chip is broken Switch output over current protection circuit is activated Please check that fluid doesn t flow at the time of zero adjustment setting. Turn power again.. If it does not return to normal condition, please contact nearest PISCO sales office. Turn power again.. If it does not return to normal condition, please contact nearest PISCO sales office. Reduce the instantaneous flow within the flow range. Turn power again.. If it does not return to normal condition, please contact nearest PISCO sales office. Increase the instantaneous flow within the flow range. Turn power again.. If it does not return to normal condition, please contact nearest PISCO sales office. Check whether load current exceeds the rating, correctly connect the controller, and turn power again. Trouble Cause Corrective action No flow display (No analog output) display remains 0. (Analog output remains V or 3V) display does not reach 0. (Analog output does not make V or 3V) Analog output is not within standard value display is not stable. (Analog output is not stable. Output is chattering.) It doesn t move at power supply on by abnormal display. Breakage of wire. Wrong connection of power source. Malfunction caused by noise. Output circuit is broken. FUS0 is broken path clogged by foreign matter. Leakage Foreign matter sticking to sensor chip. Malfunction caused by noise. Sensor chip is broken. Foreign matter sticking to sensor chip. Malfunction caused by noise. Pulsation of air Fault in power source (not enough voltage/capacity) Malfunction caused by noise. It turned on power with the button had been pushed. Recheck/repair external wiring. Connect the rated power source correctly. Keep FUS0 main body and cable away from noise source. Replace FUS0 Replace FUS0 Remove foreign matter and install filter at primary side of FUS0. Check and correct piping Replace FUS0. Keep FUS0 main body and cable away from the noise source. Replace FUS0. Replace FUS0 Keep FUS0 main body and cable away from the noise source. Reduce pulsation by installing tank, etc. Change the response time. Change the display speed. Increase the hysteresis. Supply rated voltage. Provide power source with enough capacity. Keep FUS0 main body and cable away from noise source. The power supply is put again without pushing the button. -7-

7Specifications Descriptions Connection size Working conditions Accuracy Output Install rate display Note, Integrating function Note)3,7 Full scale flow rate note) 0.5 5 0 0 50 00 00 4 φ4 quick fitting 6 φ6 quick fitting 8 φ8 quick fitting 0 φ0quick fitting Type of display 4 digits+ 4 digits colors LCD rate range F R 500 m -500 500 m 000 m -000 000 m.00 -.00.00 5.00-5.00 5.00 0.00-0.00 0.00 0.0-0.0 0.0 50.0-50.0 50.0 00.0-00.0 00.0 00-00 00 Display resolution m 0.0 0. Display range 9999999mL 99999.99L 999999.9L 9999999L Display resolution ml 0.0L 0.L L Integrating pulse output rate 5mL 0mL 0.0L 0.05L 0.L 0.L 0.5L L L Working fluid Note) 4 Clean air(jis B 839-..5.6.) Compressed air(jis B 839-...6.) N gas Maximum working pressure 0.7MPa Minimum working pressure -0.09MPa Withstanding pressure MPa Ambient temperature / humidity 50, 90%RH or less Working fluid temperature 50 (No freezing ) Accuracy assurance range 300%F.S. Linearity (display / analog output) ±3%F.S. or less (5, atmospheric pressure) Pressure characteristics ±5%F.S. or less (-0.090.7Mpa,5, atmospheric pressure criteria) Temperature characteristics ±0.%F.S./ 以下 (5 to 35 C, 5 C criteria) Repeatability (Repeat accuracy) ±%F.S. or less Response time Note)5 50ms or less N points (NPN open collector output, 50mA or less, voltage drop.4v or less) Switch output P points (PNP open collector output, 50mA or less, voltage drop.4v or less) V point ( to 5V voltage output and connected load impedance 50kΩ and over) Analog output A point (4 to 0mA current output and connected load impedance 300Ω or less) V DC-4V (0.86.4V) Power supply voltage Note)6 A DC4V (.66.4V) Current consumption Note)8 50mA or less Lead wire Φ3.7 AWG6 equivalent 5 cores(connector),outside diameter of insulator is Φ.0 Functions rate display, flow rate display-peak hold, switch output and analog output Installation attitude Both vertical and horizontal Strait piping section Not required Protective structure IEC standards IP40 Power supply and switch output reverse connection protections, and switch output Protective circuit Note)9 load short-circuit protection EMC instruction Acceptable goods Note: Converted to volumetric flow at 0 C and atmospheric pressure (0kPa) Note: late display is only the read within rough±%f.s. Therefore, the value differs from accuracy assurance range. Note3: Integrated flow display is reference value. Note4: When using compressed air, use clean air complying with JIS B 839-:003 class over.. to.6.. Compressed air from the compressor contains drainage (water, oxidized oil, foreign matter, etc.). Install a filter(filtration rating:5μm), air dryer(minimum pressure dew point 0 or less) and oil mist filter(maximum oil concentration 0.mg/m 3 ) on the primary side of the product to maintain product function. When using for purposes other than compressed air, use dry gas that does not contain corrosive elements such as chlorine, sulfur or acids, and clean gas that does not contain dust or oil mist. Note5: The response time can be selected from 50ms to 500ms (7 steps). Note6:Power supply specification vary depending on voltage output type and current output type. Note7: Integrated flow value is reset by turning power off. Note8: Current consumption is characteristics 4VDC and no load. It is changed by load. Please note it. Note9: This product s protective circuit is effective only for specific incorrect connections and load short-circuits. It does not necessarily provide protection for all incorrect connections. -8-

8Dimensions sensor (No needle valve ) Model:FUS0- - - sensor (Built-in needle valve) Model:FUS0- - - N (Through) (Through) Depth 5 Outer dimensions of fittings and other dimesnions(l H H H3 H4) Depth 5 Option parts outer dimensions Model:FUS0-B Model:FUS0-C5 Max. 30 Connector cover (Material : EPDM) Halogen free electric wire Half stripped wire Heat contracting tube Model L dimesnion FUS0-C5 040±0 FUS0-C53 3040±0 Model:FUS0-P Panel cutting dimension < Single mount > Model :FUS0-PN Panel cutting dimension <Single mount> 4-MAX R 4-MAX R -fixing screw (M3X0.5) (Tightening torque 0.06N.m) Panel holder cover Panel Stopper <Sticking mount> 4-MAX R -fixing screw (M3X0.5) (Tightening torque 0.06N.m) Panel holder cover Panel Stopper <Sticking mount> 4-MAX R Panel Holder Panel Holder Each part (H H) dimension with fittings φ4 φ6 φ8 φ0 H 8.5 30.0 H 40.5 46.5 Thickness of the panel that can be installed :0.8-6mm. Each part (H H) dimension with fittings φ4 φ6 φ8 φ0 H 8.5 30.0 H 40.5 46.5-9- Thickness of the panel that can be installed :0.8-6mm.

9How to order FUS0 -N V - F 005-4 B N 3 4 5 6 7 8 Output type Analog output type 3 direction 4 rate range (full scale flow rate) N Integrated indicator type V Voltage output(-5v) 500 m 00 0 Switch output(npn): points F Bi-directional 005 P Analog output: point A Current output(4-0ma) R One-directional 00 500 50 Integrated indicator type 0 00 Switch output(pnp): points 00 Analog output: point 050 5 0 00 00 0 5Port size 6Cable 7Bracket 8 Needle Valve 4 Quick fitting φ4 Blank None Blank None Blank None 6 Quick fittingφ6 m B With bracket N Built in needle valve 8 Quick fittingφ8 3 3m P Panel mount 0 Quick fittingφ0 Kit set Discrete option model FUS0 - B Option B C5 C53 P PN Bracket Connecter cable m Connecter cable 3m Panel mount kit set (for No needle valve type) Panel mount kit set (for built in needle valve) NIH PISCO CO., Ltd. 3884- MINAMIMINOWA, KAMIINA, NAGANO-PREF., 399-4588 JAPAN Issued:0.6. TEL :+8-(0)65-76-775 FAX: :+8-(0)65-76-773305 E-mail :intl@pisco.co.jp We reserve the right to change dimensions, specifications and design without notice. -0-