SYSTIMAX 360 ipatch InstaPATCH Fiber Shelf Instructions

Similar documents
SYSTIMAX 360 ipatch G2 High Density Sliding Fiber Shelf Instructions

ipatch Ready Upgrade Kit for SYSTIMAX 360 Fiber Shelves Instructions

SYSTIMAX 360 ipatch G2 Fiber Ultra High Density (UHD) Shelf, LC InstaPATCH Distribution Panel Instructions

SYSTIMAX 360 ipatch G2 Fiber Ultra High Density (UHD) Shelf, MPO Distribution Panel Instructions

SYSTIMAX SMB-4-3/4, SMB-8-1/2 Shelf-Mounted Cable Bracket Kits and 1000G2-XCPB Expanded Cable Protector Kit

SYSTIMAX GS3 and 1100GS6 Evolve Modular Panel Instructions

SYSTIMAX G2 4U Fixed Rear Access Combination Shelf Instructions

SYSTIMAX 360 FTP Evolve Panel Instructions

PATCHMAX GS3, GS6 and PowerSUM Modular Panels

Pretium Wall-Mountable Housing (PWH-02P/-04P/- 06P/-12P and FZB-02P-JB)

Fiber Connector Shelf (CCS)

Universal Splice Tray Installation Instructions

8400 Series Fiber Distribution System

Opticom Rack Mount Fiber Enclosures

PanView iq (PViQ) Fiber Tray

OFS Fitel LST1U-072/7 and LSTLW Instruction Sheet (LaserWave) Fiber Optic Comcode: Termination Shelf Installation

FOSC-400A4 INSTALLATION INSTRUCTION

UNPWM-U-Type Universal Wall Mount Patch Panel Instructions

INSTALLATION INSTRUCTIONS

Installation Instructions Table of Contents

<THESE INSTRUCTIONS MUST BE GIVEN TO THE END USER> B&W

Jeep JK Wrangler XHD Rear Tire Carrier

LPC Series Fiber Panel 12/24 Fiber Rack-Mount Enclosure Installation Instructions

VHM-P (Non-Locking) and VHM-PL (Locking) Variable Height Arm with Slide-In Mounting Plate

<THESE INSTRUCTIONS MUST BE GIVEN TO THE END USER> B&W

Installing the Switch

2-row and All-row systems included.

Southwest Windpower Instruction Sheet AIR-X Circuit Replacement Kit

Instructions for 2-row monitoring only

<THESE INSTRUCTIONS MUST BE GIVEN TO THE END USER> B&W Trailer Hitches 1216 Hawaii Rd / PO Box 186 Humboldt, KS P: F:

IBER DISTRIBUTION FRAME (FDF) FOR EXCHANGE SIZE 900MM x 2200MM x 300 MM

INSTALLATION INSTRUCTIONS

<THESE INSTRUCTIONS MUST BE GIVEN TO THE END USER> B&W

<THESE INSTRUCTIONS MUST BE GIVEN TO THE END USER> B&W

Fiber optic splice closure

UNP-U-Type Universal Panel Instructions

5830 Skylight, Solar Smart Retrofit Installation

Fiber Splice Panel Rack Mount User Manual

FlexJet Carriage Circuit Board (PCB) Replacement

LGT-306L / LB Club Car Precedent LED Light Bar Bumper Kit Installation Instructions

INSTALLATION & OWNER S MANUAL

Air Conditioner for M915 A0/A1 Truck

Environmental Distribution Center (EDC-06P-NH)

VHM-P (Non-Locking) Variable Height Arm with VESA Mounting Plate for 75 x 75mm or 100 x 100mm applications

UNPACK AND IDENTIFY THE FOLLOWING PARTS.

Assembly Instructions

INSTALLATION INSTRUCTIONS DODGE DAKOTA 2 KIT # 682 (2WD), 692 (4WD) 3 KIT # 683 (2WD), 693 (4WD)

Panduit PreConfigured Industrial Distribution Frame (IDF) Installation Instructions Part Numbers ZDF and ZDF

Agilent G1554A On-Column Capillary Inlet with EPC

LSS1U-144/7 FIBER OPTIC SPLICE SHELF INSTALLATION GENERAL CUSTOMER SERVICES REFERENCES TOOLS REQUIRED

SUT-250-S (These instructions are used for SUT-250-SCLC also)

MF 9690, 9790, Challenger 660, 670

Fiber Optic Above-Ground) Cross-Connect Enclosure (ACE) Model ACE-200DS Installation Guide)

GPS AutoSteer System Installation Manual

3875 Cypress Drive Petaluma, CA Fax


Desktop 5.5 Z Axis Retrofit

Instructions for 2-row monitoring only

FIST-GMS2. FIST Generic Mixed Shelf MK2. Contents. 1 Introduction. 5 Termination of the pigtails. 2 General. 6 Splicing + fiber storage

LSW Connector Module User Manual

Copyright 2004 Alcatel. All rights reserved.

Instructions for Use - Opt-X 1000i Enclosure

Installation and Service Manual

Z-Truck (Vertical Moving) Z-truck Flag. Y-Truck (Horizontal Moving) FIGURE 1: VIEW OF THE Z-TRUCK. Flexshaft Assembly

INSTALLATION INSTRUCTIONS

SUT-450-I ASSEMBLY REQUIREMENTS

OFE-CLS-Type Outside Plant (OSP) Fiber Optic Closures Instructions

OPERATION AND MAINTENANCE MANUAL

Installation Guide. Volatiles Interface for 6890 Gas Chromatograph Accessory G2319A

Overview. Chassis Packaging

JEEVES. JEEVES Installation Manual. Installation Manual The Easiest Do-It-Yourself Dumbwaiter on the Market

FIBER CONNECTOR SAFETY WARNINGS

FL2000 Termination/Splice Panels User Manual

5 Removal and replacement

LED IMPORTANT SAFETY INSTRUCTIONS

FOSC-100 B/H FOSC-100 B2/H

INSTALLATION INSTRUCTIONS

Panduit PreConfigured ZDF48-RA Industrial Distribution Frame (IDF) Installation Instructions

Installation Manual TWM Performance Short Shifter Cobalt SS/SC, SS/TC, HHR SS, Ion Redline and Saab 9-3

TOYOTA im INTERIOR LIGHT KIT Preparation

icon User s manual Table of Contents section 6 icon module installation and removal

Replacing the Gear Drive Motor Assembly and GFCI Module for Operation with the Chain Drive Motor Assembly

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS

I. Before starting installation

SLIMRACK SLIDE-OUT MOTOR AND DRIVE BLOCK REPLACEMENT

RMK HANDLEBAR KIT P/N ; ; APPLICATION BEFORE YOU BEGIN KIT CONTENTS. Verify accessory fitment at Polaris.com.

Installation Instructions Pro Bandit Shifter Fits: GM Powerglide Automatic Transmissions

MODEL 2604 WARNING <THESE INSTRUCTIONS MUST BE GIVEN TO THE END USER> Custom 5th Wheel Hitch Mounting Rail Installation Instructions

Carousel Unit User Manual Replacing the Check Stand Motor

OFS LSS1U-864/ Instruction Sheet Fiber Optic Comcode: Splice Shelf Installation

2010+ Victory Cross Country / Cross Roads Installation Guide Nov 2014

Table of Contents WARN INDUSTRIES PAGE A1

INSTALLATION INSTRUCTIONS

Signal Mirror Installation Instructions

Switch Installation. Preparing for Installation. Warnings CHAPTER

Mini-OTE 400. Mini-OTE 400. Content 1 General 1.1 General product information 1.2 Cable types 1.3 Symbols in this guide.

GPS AutoSteer System Installation Manual

8-Position Cat5E EMT Shielded Slim-Line Modular Plug

INSTALLATION INSTRUCTIONS READ THOROUGHLY BEFORE BEGINNING

Transcription:

Issue 6, June 2014 SYSTIMAX 360 ipatch InstaPATCH Fiber Shelf Instructions General The SYSTIMAX 360 ipatch InstaPATCH fiber shelf is a SYSTIMAX approved product and is available in a sliding configuration and fixed configuration. Each shelf includes one ipatch ready LC module designed for use in an ipatch System and four modules that allow connection of multi-fiber trunk cables terminated with push-on MPO connectors. Each module provides six LC duplex fiber ports. This shelf is one unit high and can be mounted in a standard 19-inch (483mm) rack with a universal hole pattern. Note: To use the SYSTIMAX 360 ipatch InstaPATCH shelf in an existing ipatch System, the ipatch managers must be running firmware version 8.1 or later. The System Manager firmware, used to manage the system, must be version 7.1 or later. We recommend that you upgrade the System Manager software to version 7.1 or a later version before you install the SYSTIMAX 360 ipatch InstaPATCH shelf. Ordering information is listed below: Material ID Part No. Description 760117424 360-iP-INSTA-LC-4OS 360G2 sliding fiber shelf with InstaPATCH 360 OptiSPEED modules 760193805 360-iP-INSTA-LC-4LS 360G2 sliding fiber shelf with InstaPATCH 360 LazrSPEED modules 760193813 360-iP-INSTA-LC-4TS 360G2 sliding fiber shelf with InstaPATCH 360 TeraSPEED modules 760183202 360-iP-INSTA-LC-4LS-FX 360G2 fixed fiber shelf with InstaPATCH 360 LazrSPEED modules SYSTIMAX 360 ipatch InstaPATCH Sliding Fiber Shelf This product is covered by one or more of the following U.S. patents or their foreign equivalents: 6285293 and 6522737. 2014 CommScope, Inc. All rights reserved Page 1 of 12

How to Contact Us To find out more about CommScope products, visit us on the web at http:/// For technical assistance: - Within the United States, contact your local account representative or technical support at 1-800-344-0223. Outside the United States, contact your local account representative or PartnerPRO Network Partner. - Within the United States, report any missing/damaged parts or any other issues to CommScope Customer Claims at 1-866-539-2795 or email to claims@commscope.com. Outside the United States, contact your local account representative or PartnerPRO Network Partner. Specifications Fiber Optic Interface Industry-standard LC Compatible Fiber Size Multimode with 50 µm core diameter, such as LazrSPEED Multimode with 62.5 µm core diameter, such as OptiSPEED Singlemode with 8.3 µm core diameter, such as TeraSPEED Environmental Data Temperature Range Humidity -40º F to 158º F (-40º C to 70º C) (storage) 23º F to 122º F (-5º C to 50º C) (operational) 95% non-condensing Tools Required Flat blade screwdriver T10 Torx driver (optional) Parts List Verify parts against the parts list below: Quantity Description 1 Shelf assembly (sliding) with panel bus jumper 1 Patch cord trough 1 Hinged door for patch cord trough 12-24 x ½ screws for mounting the shelf in a 19-inch (483mm) 4 or 23-inch (584mm) rack 2 Liquid tight cable fittings (cable glands) 2 Plastic cable tie retainers 4 Cable ties 3 Fiber routing clips 1 Instruction sheet Page 2 of 12

860479781 Separately Orderable Components Material ID Part No. Description 760039883 600-23BRKT Mounting bracket accessory kit for 23-inch (584mm) rack and ETSI rack Important Safety Cautions To reduce the risk of fire, electric shock, and injury to persons, read, understand, and adhere to the following instructions as well as any warnings marked on the product. Remote risk of electric shock. Never install the product in wet locations or during lightning storms. Never touch uninsulated communication wires or terminals. Disconnected optical components may emit invisible optical radiation that can damage your eyes. Never look directly into an optical component that may have a laser coupled to it. Serious and permanent retinal damage is possible. If accidental exposure to laser radiation is suspected, consult a physician for an eye examination. Wear safety glasses to install the shelf. Although standard safety glasses provide no protection from potential optical radiation, they offer protection from accidental airborne hardware and cleaning solvents. Precautions ipatch high density fiber modules contain fiber optic cable and passive optical components. When removed from protective packing, they should be handled carefully and installed in appropriate racks for mechanical support and protection. ipatch high density fiber modules require virtually no maintenance to maintain their performance. They contain no user-serviceable components, and any damage to the anti-tamper label or removal of top cover or front adapter mounting panel will void the warranty. Fiber optic trunk cable and jumper performance is sensitive to bending, pulling, and crushing. Minimum bend radius must be maintained during installation per the manufacturer s specification. Appropriate pulling socks must be used during installation, and pulling forces shall not exceed manufacturer s recommendations. MPO terminated trunk cables may use ribbonized fiber optic cable, which has a preferential bend axis. Use caution to avoid kinking trunk cables. ipatch high density fiber modules are preterminated, with protective dust caps installed on all adapters. IMPORTANT: Dust covers are installed in the ports to protect the fibers connected to the back of the ports. Do not remove a dust cover from a port until you connect a patch cord to that port. If you remove a patch cord later, replace dust cover in the port. Prior to installation, clean the trunk cable and jumper connectors per the manufacturer s recommendations. All wiring that connects to this equipment must meet applicable local and national building codes and network wiring standards for communication cable. Care should be taken not to compromise the stability of the rack by installation of this equipment. ipatch high density fiber modules are for use in restricted access areas only. IMPORTANT SYSTIMAX 360 ipatch InstaPATCH shelves use infrared sensing technology and should be installed where they are not exposed to direct sunlight or other infrared sources. Page 3 of 12

Step 1 Configure InstaPATCH Modules The SYSTIMAX 360 ipatch InstaPATCH fiber shelf is shipped with four InstaPATCH modules installed in the ALPHA orientation. The InstaPATCH modules must be configured for the proper polarity. Identical modules are used at both ends of a trunk cable, but module orientation is inverted from end to end. Module at one end of trunk cable must be oriented in ALPHA configuration, while module at opposite end of trunk cable must be oriented in BETA configuration. To change the orientation of the modules: 1. Slide top cover off the shelf. 2. Use a T10 Torx driver to loosen the nine captive screws securing the ipatch ready module to the shelf, as shown above on the left. Note: Use a dedicated T10 Torx driver. Drivers with interchangeable bits are too wide to access the screws. 3. Remove the ipatch ready module from the shelf and set aside module without disconnecting panel bus jumper from module. 4. Remove an InstaPATCH module, by pressing the tabs on both sides of module to release it, then pulling the module out from the front of the shelf as shown above on the right. Page 4 of 12

860479781 Module in ALPHA Orientation Module in BETA Orientation 5. Change the orientation of a module to the ALPHA or BETA orientation as shown above. 6. Repeat items 4 and 5 to change orientation of other modules. 7. Reinstall the InstaPATCH module by sliding it into the front of the shelf and pressing into place. An audible click will be heard when module is fully seated in shelf. IMPORTANT: The connector is keyed. The polarized tab on the panel connector fits into the opening in the header connector on the back of the faceplate as shown above. Ensure that the panel bus jumper is firmly connected to the back of the ipatch ready module as shown. Page 5 of 12

8. Place the ipatch ready module back on the front of the panel, aligning the captive screws with the corresponding holes in the panel. 9. Starting with the center screw, tighten the nine captive screws to secure the module to the shelf as shown. IMPORTANT: Make sure the module is fully seated on front of shelf. Tighten screws until snug. Step 2A Route Panel Bus Jumper on Sliding Shelf 1. If it has not already been removed, slide the top cover off the shelf. 2. Remove tape securing panel bus jumper to cable support. 3. Route panel bus jumper within protective corrugated tubing around end of sliding rail to outside of rail. 4. Snap corrugated tubing protecting panel bus jumper into cable retainer clip on outside of rail as shown. 5. Position corrugated tubing so that about 3 inches (76mm) of tubing extends past end of the cable retainer clip. 6. Position the exposed ribbon cable of the panel bus jumper in the flat retainer clips on the outside of the sliding rail. Page 6 of 12

860479781 Step 2B Route Panel Bus Jumper on Fixed Shelf 1. If it has not already been removed, slide the top cover off the shelf. 2. Remove tape securing panel bus jumper to cable support. 3. Route panel bus jumper around end of fixed shelf and insert into the flat retainer clip on the outside of the shelf. Page 7 of 12

Step 3 Install Shelf and Connect Panel Bus Jumper When installing multiple shelves in a rack, install the lowest shelf first and work toward the top of the rack. 1. Mount the shelf in the rack using the four mounting screws provided, as shown above and described below. Sliding shelf is shown, but fixed shelf is similar. For a 19-inch (483mm) rack, mount shelf to rack using the pre-installed mounting brackets and four 12-24 screws provided. For a 23-inch (584mm) rack, use the 600-23BRKT accessory kit (ordered separately) and install one conversion bracket on each side of shelf using four 10-32 screws included in the kit. Mount shelf to rack using four 12-24 screws provided. For an ETSI rack, use the 600-23BRKT accessory kit (ordered separately) and install one conversion bracket on one side of the shelf using two of the four 10-32 screws included in the kit. Mount shelf to rack using four M6 x 12mm screws (not provided). The shelf will not be centered in the rack. 2. Connect the keyed female 10-pin connector on the panel bus jumper into the nearest cable bus port on the panel bus. IMPORTANT: Make sure that the jumper connector is fully seated. Page 8 of 12

860479781 3. Install the spare port built into the jumper cordage into the panel bus frame by turning it at an angle, inserting into frame, and turning it back perpendicular to the frame. Step 4 Install Patch Cord Trough Shelf Standoff Captive screw (2 places) Trough Standoff Note: Shelf shown is representative, actual part may vary. For Unpopulated and Modular Shelves 1. Position trough on shelf so that indentions behind captive screws rest on the standoffs. 2. Using a Phillips head screwdriver, tighten the captive screw on each end of trough to secure it to shelf. Note: If installing the trough on a sliding shelf, pull the shelf out enough to support the faceplate from behind before tightening the captive screws. Page 9 of 12

Step 5 Install Trunk Cable 1. Pull the trunk cable to the rack and determine the best way to route the cable to the shelf (from above or below). Note: When using a distribution frame, route and loosely secure trunk cable to cable retainers and cable retainer brackets. 2. Follow the manufacturer s instructions to remove pulling sock from trunk cable. 3. Remove a plastic plug from an appropriate cable entry hole in the back of the shelf. 4. Loosen the gland nut on the cable gland. The gland nut does not have to be removed to install the cable gland. See detail shown in the following figure. 5. Feed sub-unit tubes through opening in shelf and temporarily coil them loosely inside shelf. 6. Rotate the gland nut as required to allow it to pass through the opening and enter the shelf. Note: It may be necessary to temporarily remove a plug from an adjacent opening to provide sufficient clearance for the gland nut to be inserted through the opening. 7. Insert threaded body of cable gland into opening and tighten gland nut onto threaded section to secure cable gland unit to shelf. 8. Insert a cable tie retainer (provided) up through the hole in the cable support on the rear of the shelf on the side opposite from where the cable enters the shelf. See detail above. For example, if the cable enters the shelf on the right side, use the hole on the left side of the cable support. Note: Two cable tie retainers are provided for your convenience. 9. Insert a cable tie (provided) through the cable tie retainer and tighten it enough to loosely secure the trunk cable to the cable support. Page 10 of 12

860479781 IMPORTANT: Do not tighten the cable tie completely. Leave enough slack so that the cable moves freely when you slide the shelf out from the rack. 10. Secure the trunk cable to the back of the rack approximately 7 inches (178mm) above the shelf as shown on the left rail in the figure above. 11. For the sliding shelf, extend and retract the shelf to make sure it slides freely and trunk cable and panel bus jumper does not bind. Note: The ribbon cable of the panel bus jumper may slide in the corrugated tubing. Step 6 Connect Cables Connector Insertion Connector Removal Ribbed section Coupler Boot 1. Remove protective dust covers from MPO connectors on the cable and MPO couplers on the back of InstaPATCH modules. 2. Grasp connector by its boot, near the base of connector (shown above). Insert MPO connector into coupler until it clicks into place. Note: The MPO connection is keyed. The polarized tab on the connector fits into the opening on a coupler on the module. 3. Repeat item 2 to insert each of the trunk cable s MPO connectors into MPO couplers on an InstaPATCH module. 4. To unplug an MPO connector, grasp the ribbed sleeve section and pull connector out of coupler. Do not pull on the boot to unplug an MPO connector. Page 11 of 12

Step 7 Install Cover and Door Cover Door Press both top corners to close Install top cover and trough door (both provided) to shield shelf from foreign particles. The cover, which is made of clear, flame-retardant plastic, slides on and off shelf. The door for the patch cord trough is hinged and has touch-latches for closing and opening. 1. Slide cover through flanges on shelf until cover reaches the back wall of shelf. 2. Remove door from protective wrapping. 3. Orient door at an angle from trough and position hinge pins on door into hinge sockets on trough. 4. Using one hand to support bottom of trough on one end, push down on inside of door over hinge pins with other hand to seat pins into hinge sockets. 5. Repeat on other end to secure door to trough. 6. Pivot door into the vertical position until strikes engage latches and door snaps into the closed position with an audible click. 7. Door may be reopened by pulling on both upper corners of door (opposite strikes) until the latches release (verified by an audible click). Note: Trough door may be removed when opened to a 45 position, by holding one of the side hinge brackets and pulling upward until hinge pins release from socket. Lift door to release from hinge socket on other side bracket. 8. Fully retract the shelf in the rack. Page 12 of 12