Pilan. Hydraulic Oil Coolers and Heat Exchangers

Similar documents
Plate Heat Exchangers

Lecture 2: Thermal Design Considerations

BASCO TYPE OP (AEW) HEAT EXCHANGERS

Generator and Motor Coolers

STOCK PRODUCTS CATALOGUE

Delivering unsurpassed quality, design and value.

Oil Coolers 2000 series

Part C: Electronics Cooling Methods in Industry

BASCO PIPELINE AFTERCOOLERS. ...world leaders in heat transfer technology

SANITARY APPLICATIONS

Thermal Unit Operation (ChEg3113)

Heat Exchangers (Chapter 5)

Series: EC & ED. EC & ED RPM - 60Hz. (See Indivdual curves for symbol number)

SPH3U UNIVERSITY PHYSICS

Hydraulics. Axial Piston Pumps Series PVP. Introduction. With thru shaft option for multiple pump options Swash plate type for open circuit

Fluid Cooling Brazed Plate BPSW Series

Series: EC & ED. EC & ED RPM - 60Hz. (See Indivdual curves for symbol number)

SRX. Remediation Pumps. Simply Reliable

HIGH PERFORMANCE SEALING

Thermal Unit Operation (ChEg3113)

SHELL & TUBE HEAT EXCHANGER

Design and Fabrication of Shell and Tube Type Heat Exchanger and Performance Analysis

Küba Green Line XXXXXXXXXX. Küba market plus SP. High Performance Unit Cooler.

PV Newsletter Monthly Publication from CoDesign Engineering Skills Academy

fåçìëíêá~ä=~áê=åççäéêë=qvo pí~åç~êç=åççäéêë=ïáíü=ëí~áåäéëë=ëíééä=íìäáåö

Article on Sheath materials, Thermowells, Fittings, and Terminations

Uniwat. Resilient Seated Gate Valves

Küba SG industrial

Programme area 4a. Fluid Energy Machines

W91/W94 Series TEMPERATURE REGULATORS. Self-Operated Temperature Regulators. Design & Operation W91 Non-Indicating W94 Dial Thermometer

CFD ANALYSIS OF DOUBLE HELICAL PIPE PARALLEL& COUNTER FLOW HEAT EXCHANGER

TVFC Dry and adiabatic cooling

STAINLESS STEEL MANIFOLDS FOR RADIANT SYSTEMS CREATION AND DIFFUSION OF THE STAINLESS STEEL MANIFOLD USE DIAGRAMS OF STAINLESS STEEL MANIFOLDS

SECTION Pressure & Temperature Control

TPV Variable Displacement Closed Loop System Axial Piston Pump THE PRODUCTION LINE OF HANSA-TMP HT 16 / M / 851 / 0813 / E

Numerical Simulation of the Thermoelectric Model on Vehicle Turbocharged Diesel Engine Intercooler

Design, Fabrication and Testing of helical tube in tube coil heat exachanger

Air-Cooled Fluid Cooler

EXPERIMENTAL INVESTIGATIONS OF DOUBLE PIPE HEAT EXCHANGER WITH TRIANGULAR BAFFLES

1/11 29/06/2016 CONTENTS 1. GENERAL DUCTS, AIR VENTS, VALVES MONOBLOCK UNITS FILTRATION CONTROL...

CONJUGATE HEAT TRANSFER ANALYSIS OF HELICAL COIL HEAT EXCHANGE USING CFD

Photo: Swedish Coast Guard. Impeller Pumps

A Review on Experimental Investigation of U-Tube Heat Exchanger using Plain Tube and Corrugated Tube

^áêëçåâ=ìåáí=åççäéêë=qvoj^ pí~åç~êç=åççäéêë=ïáíü=pí~áåäéëë=píééä=íìäáåö

Internal Combustion Engines

OTHER PRODUCTS FROM THE TURNBULL & SCOTT RANGE

Fabri-Valve XS150. Knife Gate Valve

Design and Performance Study of Shell and Tube Heat Exchanger with Single Segmental Baffle Having Perpendicular & Parallel-Cut Orientation.

Heat Pipe Selection Guide Heat Pipe Introduction

Title: Optimal Design of a Thermoelectric Cooling/Heating for Car Seat Comfort Developed by Dr. HoSung Lee on 10/18/2014 Car seat comfort is becoming

Cooling System Description and Operation

THERMAL ANALYSIS OF WASTE HEAT RECOVERY UNIT USING THE EXHAUST GAS EMITTED FROM INTERNAL COMBUSTION ENGINE

THERMAL ANALYSIS OF WASTE HEAT RECOVERY UNIT USING THE EXHAUST GAS EMITTED FROM INTERNAL COMBUSTION ENGINE

Installation Operation Maintenance. LSSN Butterfly Valve AGA Approved 50MM - 150MM. QAD#IM6055.REVA

611H Flo-Con Pressure Regulators & Valves

Fact Sheet Sky CPC 58

KLIMA Active Chilled Beams

SOLENOID VALVES FOR REFRIGERATING SYSTEMS

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS SERIE BQ

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS SERIE BQ

EXPANSION JOINT SELECTION GUIDE

THRU DRIVE HYDRAULIC VANE PUMP TQ/TV SERIES

HEAT EXCHANGER OVERVIEW

SRX R. Remediation Pumps. Simply Reliable

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BV SERIES

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS SERIE BV

Küba Green Line. Küba comfort DP. Ceiling Air Cooler.

RETURN FILTERS. MATERIALS Head: Aluminium alloy Spin-on cartridge: Steel Bypass valve: Polyammide Seals: NBR Nitrile Indicator housing: Brass

General catalogue incl. replacement lists

Worcester 18/19 Series. Modular Multi-Way Ball Valves

LMP series. 305 Low & Medium Pressure filters MULTIPORT. Maximum pressure up to 80 bar - Flow rate up to 200 l/min

Guardian zf04 Portable Filtration Systems

Name Date. True-False. Multiple Choice

Module 7: Cooling System Components

Heat Exchangers & Enhanced Surface

FC SERIES FLUID COOLERS THE LEADER IN THE INDUSTRY FOR ALL YOUR HVAC NEEDS. Replacement Coils Heat Exchangers Fan Coils

PadaEngineering THERMAL AND MECHANICAL ANALYSIS AND DESIGN FAST PROTOTYPING UP TO DATE CNC AND TECHNOLOGY CONTINUOUS QUALITY IMPROVEMENTS ISO 9001

Gauges, Sight Glasses and Vacuum Breakers

Design/Modeling and Thermal Analysis on Cylinder Head of I.C Engine

Inline Filters NF. Flow rates up to 3,500 l/min Pressure range 25 bar Material: Aluminium / Aluminium-Cast Iron

Experiment No: 2. To determine the effectiveness of shell and tube, cross flow & plate heat exchangers. Heat Exchangers. Plate-type Extended surfaces

Commissioning Manual PLATE HEAT EXCHANGER. Customer Name: Serial number: Purchase order number: Project:

Differential Temperature Controller

Vickers 45. VMQ Series 30 Vane Pumps. Fixed Displacement, For Industrial and Mobile Applications (4.188)

GVK Series (Steam-to-Steam) Clean Steam Generators

Chapter 29 Electromagnetic Induction and Faraday s Law

Low Profile Unit Cooler

Instruction manual. Installation requirements. Power Take-Off. Pump mounting: Spline shaft DIN 5462 / ISO 14. Mounting flange ISO 7653-D.

THERMAL ANALYSIS OF HELICALLY GROOVED COIL IN A CONCENTRIC TUBE HEAT EXCHANGER

HP-Tool-8MM. HP-Tool-4MM. 8mm Heat Pipe Bending Tool

Complete HVAC Capability

ENGINE & WORKING PRINCIPLES

Technical Notes by Dr. Mel

Vane Pumps. VMQ Series Vane Pumps For Industrial and Mobile Applications Displacements to 215 cm 3/ r (13.12 in 3 /r) Pressures to 260 bar (3800 psi)

Influence of Ambient Temperature Conditions on Main Engine Operation of MAN B&W Two-stroke Engines

AUXILIARY COMPONENTS

Plate Heat Exchangers

FLUID COOLING Shell & Tube EK Series

Exhaust Emission Reduction in Two-Wheeler by Pre Heating Method

PROCESS & AUTOMATED VALVES

Transcription:

Pilan Hydraulic Coolers and Heat Exchangers www.comeval.es

Toraflex - is a trademark of Comeval Valve Systems Data subject to change without prior notice

Pilan Hydraulic Coolers and Heat Exchangers Index General Design Considerations Industrial Shell & Tube Heat Exchangers Series A Series B Series C Series D Series E Series F Marine Shell & Tube Heat Exchangers Series AM Series BM Series CM Series DM Series EM Series FM Pressure Drop Data Sheet 4 8 9 10 11 12 13 14 15 16 17 18 19 20 21 3

Pilan Hydraulic Coolers and Heat Exchangers General Design Considerations A heat exchanger is a device built for effi cient heat transfer from one fl uid to another, both fl uids are separated by a solid wall so that they never mix and are directly contacted thus avoiding contamination. They are widely used in industrial, marine, mining, automotive, chemical and process, Hot water Generation, solar energy, Heating, Ventilation and Air Conditioning Systems. The exchange of heat (energy) from one unit to another is of essence in our today s industry. In fact, no industrial processes to manufacture goods, heating and cooling homes and public places, energy generation and other daily activities could take place without this exchange of heat. There are several sort of Heat Exchanger Desings, the shell and tube heat exchanger is usually the best for higher applications and consists of a series of fi nned tubes, through which one of the fl uids runs. The second fl uid runs over the fi nned tubes to be heated or cooled. Temperature and resistance is set by the choice of materials of its components. The main advantage stems on the easy maintenance thanks to the removable tube stack although surface exchange id smaller than others thus requiring extra length. Another type of heat exchanger is the plate heat exchanger. One is composed of multiple, thin, slightly-separated plates that have very large surface areas and fl uid fl ow passages for heat transfer. This stacked-plate arrangement can be more effective, in a given space, than the shell and tube heat exchanger. Advances in gasket and brazing technology have made the plate type heat exchanger increasingly practical. In HVAC applications, large heat exchangers of this type are called plate-and-frame; when used in open loops, these heat exchangers are normally of the gasketed type to allow periodic disassembly, cleaning, and inspection. There are many types of permanently-bonded plate heat exchangers such as dip-brazed and vacuum-brazed plate varieties, and they are often specified for closed-loop applications such as refrigeration. Plate heat exchangers also differ in the types of plates that are used, and the configurations of those plates. Some plates may be stamped with chevron or other patterns, where others may have machined fins and/or grooves. Other type of Heat Exchangers can be encountered in the market although are not part of the PILAN range, such as Fan coils, Evaporators, Radiators and other devices suited to specific areas of application. Pilan - is a trademark of Comeval Valve Systems Data subject to change without prior notice Useful Terminology Heat transfer is the passage of thermal energy from a hot to a cold body. When a physical body, e.g. an object or fl uid, is at a different temperature than its surroundings or another body, transfer of thermal energy, also known as heat transfer, occurs in such a way that the body and the surroundings reach thermal equilibrium. Heat transfer always occurs from a hot body to a cold one. Energy occurs mainly through conduction, convection or radiation. Heat transfer can never be stopped; it can only be slowed down. Heat - a transfer of thermal energy, (i.e., of energy and entropy) from hotter material to cooler material. Heat transfer may change the internal energy of materials. Internal Energy the internal vibrational energy that the molecules or electrons composing all materials contain. Conduction transfer of heat by electron diffusion or phonon vibrations. Convection transfer of heat by conduction in a moving medium, such as a fl uid. Radiation transfer of heat by electromagnetic radiation or, equivalently, by photons. Approach Temperature - is defi ned as the hot fl uid outlet temperature minus the cold fl uid inlet temperature 4

Pilan Hydraulic Coolers and Heat Exchangers General Design Considerations Theory and Application of Shell & Tube Heat Exchangers Two fluids, of different starting temperatures, fl ow through the heat exchanger. One fl ows through the tubes (the tube side) and the other s outside the tubes but inside the shell (the shell side). Heat is transferred from one fl uid to the other through the tube walls, either from tube side to shell side or vice versa. The fl uids can be either liquids or gases on either the shell or the tube side. In order to transfer heat efficiently, a large heat transfer area should be used, so there are many tubes. In this way, waste heat can be put to use. This is a great way to conserve energy. Heat exchangers with only one phase (liquid or gas) on each side can be called one-phase or single-phase heat exchangers. Twophase heat exchangers can be used to heat a liquid to boil it into a gas (vapor), sometimes called boilers, or cool a vapour to condense it into a liquid (called condensers), with the phase change usually occurring on the shell side. Boilers in steam engines are typically large, usually cylindrically-shaped shell-and-tube heat exchangers. In large power plants with steam-driven turbines, shell-and-tube condensers are used to condense the exhaust steam exiting the turbine into condensate water which can be recycled back to be turned into steam, possibly into a shell-and-tube type boiler. There can be many variations on the shell and tube design. Typically, the ends of each tube are connected to plenums (sometimes called water boxes or ports) through holes in tubesheets. The tubes may be straight or bent in the shape of a U, called U-tubes. The following sketch shows a typical U-Tube Heat Exchanger with all its components identifi ed: Most shell-and-tube heat exchangers are either 1, 2, or 4 pass designs on the tube side. This refers to the number of times the fl uid in the tubes passes through the fl uid in the shell. In a single pass heat exchanger, the fl uid goes in one end of each tube and out the other. 5

Pilan Hydraulic Coolers and Heat Exchangers General Design Considerations Flow arrangement The arrangement is of great importance for Heat Exchangers performance. Flow arrangement indicates the sense on which s are desinged to fl ow. Heat exchangers may be classifi ed according to their fl ow arrangement as follows: Parallel- heat exchangers, the two fl uids enter the exchanger at the same end, and travel in parallel to one another to the other side. (B in the below sketch). Counter- heat exchangers, the two fl uids enter the exchanger from opposite ends. The counter current design is most effi cient, in that it can transfer the most heat. In a cross-fl ow heat exchanger, the fl uids travel roughly perpendicular to one another through the exchanger. (A in the below sketch). Pilan - is a trademark of Comeval Valve Systems Data subject to change without prior notice For efficiency, heat exchangers are designed to maximize the surface area of the wall between the two fl uids, while minimizing resistance to fluid through the exchanger. The exchanger s performance can also be affected by the addition of fi ns or corrugations in one or both directions, which increase surface area and may channel fl uid fl ow or induce turbulence. Optimized devices are known as compact heat exchangers. Shell and tube heat exchanger, single pass (parallel fl ow) Shell and tube heat exchanger, two pass tube side (counter fl ow) 6

Pilan Hydraulic Coolers and Heat Exchangers General Design Considerations Concurrent exchange and countercurrent exchange The diagram presents a generic representation of a countercurrent exchange system, with two parallel tubes containing fl uid separated by a permeable barrier. The property to be exchanged, whose magnitude is represented by the shading, transfers across the barrier in the direction from greater to lesser according to the second law of thermodynamics. With the two fl ows moving in opposite directions, the countercurrent exchange system maintain a constant gradient between the two fl ows over their entire length. With a sufficiently long length and a suffi ciently low fl ow rate this can result in almost all of the property being transferred. By contrast, in the concurrent (or co-current, parallel) exchange system the two fl uid fl ows are in the same direction. As the diagram shows, a concurrent exchange system has a variable gradient over the length of the exchanger and is only capable of moving half of the property from one fl ow to the other, no matter how long the exchanger is. It can t achieve more than 50%, because at that point, equilibrium is reached, and the gradient declines to zero. 7

Pilan Hydraulic Coolers and Heat Exchangers Single Phase Shell & Tube Heat Exchangers Series A to F The PILAN range of Single Phase Heat Exchangers for liquids consist of a standardised manufacture programme of 6 series and 33 models for thermal transfer application with heat load capabilities well up to 500 KW. Each Unit provides a specifi c performance depending on the process parameters which, conveniently, entered into our selection programme will identify a range of 2 to 3 models that can accommodate to the required service. These Units are manufactured against our inventory of more than 1000 models for immediate delivery being a cheap option thanks to the scale production methods. The main range covers for Hydraulic Coolers (hydraulic oil as process fl uid), Solar Heat Exchangers (to provide hot water from the sun energy obtained through solar panels), Swimming Pool Exchangers (to heat water pools or, otherwise, keep pools cool), coolers for underground duties and other applications within the liquid / liquid fluid phase parameter. All exchangers are based on the designs shown on these data sheets with just some likely variations depending on the duty sector. Main design advantages: 1 Floating Tube Stack; inserted into the accurately machined shell, no recess between the shell and the outside baffl es of the tube stack to avoid thermal loss and fully replaceable for easy maintenance. 2 Brazed or mechanically expanded plate sheet; ensuring tightness of tube circuit to avoid fl uid contamination. Can be brazed to Tin or silver process. Pilan - is a trademark of Comeval Valve Systems Data subject to change without prior notice 3 Three Passes Circuit arrangement; with water inlet and outlet ports in opposite sides. The multiple tube stack baffl e arrangement drives the process fluid across the outside path from inlet to outlet ports ensuring maximal thermal exchange with the cooling medium. Smaller physical units can accomplish the requested heat power thus being lighter and more economical. 4 Bolted Covers; to ease permanent access to the tube stack for maintenance operations. Made in Hot pressed brass or Bronze as standard to avoid pipe work connection clogging. 5 Finned Tubes; precision rolled, cut to each series length, with bevelled tube ends. Standard 6.5 mm O.D and 0.3 mm wall thickness what increases the thermal exchange properties. 6 Integral anchoring; what provides robustness to the exchanger and eases anchoring to the equipment if wished. 7 Draining Plug; For fl uid emptying during maintenance operations. It is made in brass material to avoid jamming. 8

Pilan Hydraulic Coolers and Heat Exchangers Hydraulics Coolers - Series A PILAN Shell and Tube Heat Exchangers are designed in a three passes tube stack arrangement with cooling fluid inlet and outlet in opposite sides and counter current fluids. Tube stack is fully floating type thus thermal stresses are minimised while maintenance operations are eased. PILAN range of Industrial Shell & Tube Heat Exchangers are suitable for any sort of heat transfer fluids, heating or cooling process fluids. Its use is restricted to liquid phase fluids and material compatibility should be observed. MAWP: oil 14 bar, water 10 bar * MAWT: 120ºC (180ºC with VITON seals) * Testing Standard: BS6755 Stabillity Test performed at 20 bar, Sealing Leakage Test at 14 bar. Dimensions Model A B C D E-F Weight TP-A1 195 72 38 Ø86 3/4 3 TP-A2 263 138 103 Ø86 3/4 3,5 TP-A3 349 225 189 Ø86 3/4 4 TP-A4 448 326 288 Ø86 3/4 4,7 TP-A5 576 450 415 Ø86 3/4 5,5 Length Units expressed in mm, Diametres in Inches / Weight in Kgs General Arrangement Drawings pdf or Auto-Cad formats are available on request. Parts and Materials Part Name Material 1 Shell Aluminium /Bronze/Cast Iron 2 Tube Stack 2.1 Tubes Copper / Copper-Nickel / St. Steel 2.2 Tube plates Brass / Bronze 2.3 Baffles Aluminium 2.4 Welding Tin welded 60/40 3 End caps Brass / Bronze 4 Seals NBR / Viton 5 Cover screws Steel 6 Drain plugs Brass Remarked materials denote standard construction for Industrial Units. Performance Graphs Flow Rate Model Heat dissipated (kw) (l/ min) (l/min) Surface (m2) TP-A1 3 30 15 0,10 0,02 0,13 TP-A2 6 46 23 0,19 0,05 0,22 TP-A3 9 56 28 0,36 0,09 0,32 TP-A4 13 64 32 0,60 0,13 0,46 TP-A5 16 56 28 0,56 0,12 0,68 Maximal Fresh Flow Rate Capacity: 50 l/min (35 l/min if sea water).this table means a typical performance of the shown units at given average process data of oil outlet temperature : 50ºC; Inlet Temperature: 25ºC, Viscosity of : 38Cst with SAE 30 type and 50ºC. Any other change in the chosen parametres could result in a different oil cooler selection. Temperature Correction Factors Graphs were plotted using the parametres shown in the right side table. For oil graphs see separated sheet. When temperature gap between oil outlet and water inlet exceeds the given 25ºC the following correction factors should be used: 10ºC: 0.4 / 15ºC: 0.6 / 20ºC: 0.8 / 30ºC: 1.2 / 35ºC: 1.4 / 40ºC: 1.6 (multiply KW by the suitable correction factor). Flow Rate Correction Factors For water rates other than 50% of the oil rate, the following correction factors should be used: 25%: 0.8 / 100%: 1.2 (multiply the rate by the suitable correction factor). Pressure Drop Graphs for primary and secondary circuits are available at our Technical Dept. Please consult your nearest PILAN distributor. 9

Pilan Hydraulic Coolers and Heat Exchangers Hydraulics Coolers - Series B PILAN Shell and Tube Heat Exchangers are designed in a three passes tube stack arrangement with cooling fluid inlet and outlet in opposite sides and counter current fluids. Tube stack is fully floating type thus thermal stresses are minimised while maintenance operations are eased. PILAN range of Industrial Shell & Tube Heat Exchangers are suitable for any sort of heat transfer fluids, heating or cooling process fluids. Its use is restricted to liquid phase fluids and material compatibility should be observed. MAWP: oil 14 bar, water 10 bar * MAWT: 120ºC (180ºC with VITON seals) * Testing Standard: BS6755 Stabillity Test performed at 20 bar, Sealing Leakage Test at 14 bar. Dimensions Model A B C D E-F Weight TP-B1 273 123 109 Ø108 1 5 TP-B2 355 205 191 Ø108 1 6 TP-B3 452 302 289 Ø108 1 7 TP-B4 587 437 425 Ø108 1 8,2 TP-B5 730 580 566 Ø108 1 10 Length Units expressed in mm, Diametres in Inches / Weight in Kgs General Arrangement Drawings pdf or Auto-Cad formats are available on request. Parts and Materials Part Name Material 1 Shell Aluminium /Bronze/Cast Iron 2 Tube Stack 2.1 Tubes Copper / Copper-Nickel / St. Steel 2.2 Tube plates Brass / Bronze 2.3 Baffles Aluminium 2.4 Welding Tin welded 60/40 3 End caps Brass / Bronze 4 Seals NBR / Viton 5 Cover screws Steel 6 Drain plugs Brass Pilan - is a trademark of Comeval Valve Systems Data subject to change without prior notice Remarked materials denote standard construction for Industrial Units. Performance Graphs Graphs were plotted using the parametres shown in the right side table. For oil graphs see separated sheet. Flow Rate Correction Factors Flow Rate Model Heat dissipated (kw) Maximal Fresh Flow Rate Capacity: 80 l/min (50 l/min if sea water).this table means a typical performance of the shown units at given average process data of oil outlet temperature : 50ºC; Inlet Temperature: 25ºC, Viscosity of : 38Cst with SAE 30 type and 50ºC. Any other change in the chosen parametres could result in a different oil cooler selection. Temperature Correction Factors When temperature gap between oil outlet and water inlet exceeds the given 25ºC the following correction factors should be used: 10ºC: 0.4 / 15ºC: 0.6 / 20ºC: 0.8 / 30ºC: 1.2 / 35ºC: 1.4 / 40ºC: 1.6 (multiply KW by the suitable correction factor). For water rates other than 50% of the oil rate, the following correction factors should be used: 25%: 0.8 / 100%: 1.2 (multiply the rate by the suitable correction factor). (l/ min) (l/min) Surface (m2) TP-B1 8 66 33 0,16 0,02 0,33 TP-B2 12 80 40 0,32 0,03 0,48 TP-B3 18 104 52 0,96 0,07 0,66 TP-B4 25 106 53 1 0,11 0,90 TP-B5 29 98 49 1,04 0,14 1,16 10 Pressure Drop Graphs for primary and secondary circuits are available at our Technical Dept. Please consult your nearest PILAN distributor.

Pilan Hydraulic Coolers and Heat Exchangers Hydraulics Coolers - Series C PILAN Shell and Tube Heat Exchangers are designed in a three passes tube stack arrangement with cooling fluid inlet and outlet in opposite sides and counter current fluids. Tube stack is fully floating type thus thermal stresses are minimised while maintenance operations are eased. PILAN range of Industrial Shell & Tube Heat Exchangers are suitable for any sort of heat transfer fluids, heating or cooling process fluids. Its use is restricted to liquid phase fluids and material compatibility should be observed. MAWP: oil 14 bar, water 10 bar * MAWT: 120ºC (180ºC with VITON seals) * Testing Standard: BS6755 Stabillity Test performed at 20 bar, Sealing Leakage Test at 14 bar. Dimensions Model A B C D E-F Weight TP-C1 372 182 93 Ø130 1 1/4 9 TP-C2 472 287 193 Ø130 1 1/4 10 TP-C3 600 415 320 Ø130 1 1/4 12,5 TP-C4 744 557 465 Ø130 1 1/4 14,5 TP-C5 922 737 643 Ø130 1 1/4 17,5 Length Units expressed in mm, Diametres in Inches / Weight in Kgs General Arrangement Drawings pdf or Auto-Cad formats are available on request. Parts and Materials Part Name Material 1 Shell Aluminium /Bronze/Cast Iron 2 Tube Stack 2.1 Tubes Copper / Copper-Nickel / St. Steel 2.2 Tube plates Brass / Bronze 2.3 Baffles Aluminium 2.4 Welding Tin welded 60/40 3 End caps Brass / Bronze 4 Seals NBR / Viton 5 Cover screws Steel 6 Drain plugs Brass Remarked materials denote standard construction for Industrial Units. Performance Graphs Graphs were plotted using the parametres shown in the right side table. For oil graphs see separated sheet. Flow Rate Correction Factors Flow Rate Model Heat dissipated (kw) Maximal Fresh Flow Rate Capacity: 140 l/min (90 l/min if sea water).this table means a typical performance of the shown units at given average process data of oil outlet temperature : 50ºC; Inlet Temperature: 25ºC, Viscosity of : 38Cst with SAE 30 type and 50ºC. Any other change in the chosen parametres could result in a different oil cooler selection. Temperature Correction Factors When temperature gap between oil outlet and water inlet exceeds the given 25ºC the following correction factors should be used: 10ºC: 0.4 / 15ºC: 0.6 / 20ºC: 0.8 / 30ºC: 1.2 / 35ºC: 1.4 / 40ºC: 1.6 (multiply KW by the suitable correction factor). For water rates other than 50% of the oil rate, the following correction factors should be used: 25%: 0.8 / 100%: 1.2 (multiply the rate by the suitable correction factor). (l/ min) (l/min) Surface (m2) TP-C1 16 100 50 0,28 0,04 0,64 TP-C2 26 120 60 0,55 0,07 0,90 TP-C3 36 140 70 0,74 0,13 1,23 TP-C4 48 160 80 1,06 0,17 1,60 TP-C5 56 140 70 0,95 0,16 2,07 Pressure Drop Graphs for primary and secondary circuits are available at our Technical Dept. Please consult your nearest PILAN distributor. 11

Pilan Hydraulic Coolers and Heat Exchangers Hydraulics Coolers - Series D PILAN Shell and Tube Heat Exchangers are designed in a three passes tube stack arrangement with cooling fluid inlet and outlet in opposite sides and counter current fluids. Tube stack is fully floating type thus thermal stresses are minimised while maintenance operations are eased. PILAN range of Industrial Shell & Tube Heat Exchangers are suitable for any sort of heat transfer fluids, heating or cooling process fluids. Its use is restricted to liquid phase fluids and material compatibility should be observed. MAWP: oil 14 bar, water 10 bar * MAWT: 120ºC (180ºC with VITON seals) * Testing Standard: BS6755 Stabillity Test performed at 20 bar, Sealing Leakage Test at 14 bar. Pilan - is a trademark of Comeval Valve Systems Data subject to change without prior notice 12 Dimensions Model A B C D E-F Weight TP-D1 505 270 109 Ø162 1 1/2 20 TP-D2 634 402 238 Ø162 1 1/2 24 TP-D3 780 546 384 Ø162 1 1/2 27 TP-D4 954 722 558 Ø162 1 1/2 32 TP-D5 1.160 928 764 Ø162 1 1/2 38 TP-D6 1.364 1.132 968 Ø162 1 1/2 45 Length Units expressed in mm, Diametres in Inches / Weight in Kgs General Arrangement Drawings pdf or Auto-Cad formats are available on request. Parts and Materials Part Name Material 1 Shell Aluminium /Bronze/Cast Iron 2 Tube Stack 2.1 Tubes Copper / Copper-Nickel / St. Steel 2.2 Tube plates Brass / Bronze 2.3 Baffles Aluminium 2.4 Welding Tin welded 60/40 3 End caps Brass / Bronze 4 Seals NBR / Viton 5 Cover screws Steel 6 Drain plugs Brass Remarked materials denote standard construction for Industrial Units. Performance Graphs Graphs were plotted using the parametres shown in the right side table. For oil graphs see separated sheet. Flow Rate Correction Factors Flow Rate Model Heat dissipated (kw) Maximal Fresh Flow Rate Capacity: 190 l/min (110 l/min if sea water).this table means a typical performance of the shown units at given average process data of oil outlet temperature : 50ºC; Inlet Temperature: 25ºC, Viscosity of : 38Cst with SAE 30 type and 50ºC. Any other change in the chosen parametres could result in a different oil cooler selection. Temperature Correction Factors When temperature gap between oil outlet and water inlet exceeds the given 25ºC the following correction factors should be used: 10ºC: 0.4 / 15ºC: 0.6 / 20ºC: 0.8 / 30ºC: 1.2 / 35ºC: 1.4 / 40ºC: 1.6 (multiply KW by the suitable correction factor). For water rates other than 50% of the oil rate, the following correction factors should be used: 25%: 0.8 / 100%: 1.2 (multiply the rate by the suitable correction factor). (l/ min) (l/min) Surface (m2) TP-D1 40 180 90 0,40 0,07 1,58 TP-D2 52 200 100 0,55 0,09 2,14 TP-D3 66 220 110 0,62 0,12 2,79 TP-D4 84 240 120 0,80 0,16 3,57 TP-D5 108 260 130 1 0,19 4,48 TP-D6 120 240 120 0,96 0,21 5,38 Pressure Drop Graphs for primary and secondary circuits are available at our Technical Dept. Please consult your nearest PILAN distributor.

Pilan Hydraulic Coolers and Heat Exchangers Hydraulics Coolers - Series E PILAN Shell and Tube Heat Exchangers are designed in a three passes tube stack arrangement with cooling fluid inlet and outlet in opposite sides and counter current fluids. Tube stack is fully floating type thus thermal stresses are minimised while maintenance operations are eased. PILAN range of Industrial Shell & Tube Heat Exchangers are suitable for any sort of heat transfer fluids, heating or cooling process fluids. Its use is restricted to liquid phase fluids and material compatibility should be observed. MAWP: oil 14 bar, water 10 bar * MAWT: 120ºC (180ºC with VITON seals) * Testing Standard: BS6755 Stabillity Test performed at 20 bar, Sealing Leakage Test at 14 bar. Dimensions Model A B C D E-F Weight TP-E1 675 372 239 Ø198 2 33 TP-E2 816 513 380 Ø198 2 39 TP-E3 998 696 560 Ø198 2 45 TP-E4 1.204 901 766 Ø198 2 54 TP-E5 1.408 1.102 968 Ø198 2 64 TP-E6 1.712 1.406 1.272 Ø198 2 74 Length Units expressed in mm, Diametres in Inches / Weight in Kgs General Arrangement Drawings pdf or Auto-Cad formats are available on request. Parts and Materials Part Name Material 1 Shell Aluminium /Bronze/Cast Iron 2 Tube Stack 2.1 Tubes Copper / Copper-Nickel / St. Steel 2.2 Tube plates Brass / Bronze 2.3 Baffles Aluminium 2.4 Welding Tin welded 60/40 3 End caps Brass / Bronze 4 Seals NBR / Viton 5 Cover screws Steel 6 Drain plugs Brass Remarked materials denote standard construction for Industrial Units. Performance Graphs Flow Rate Model Heat dissipated (kw) (l/ min) (l/min) Surface (m2) TP-E1 76 320 160 0,44 0,09 3,27 TP-E2 106 360 180 0,64 0,13 4,24 TP-E3 134 400 200 0,90 0,20 5,45 TP-E4 175 420 210 1,10 0,25 6,82 TP-E5 205 400 200 1,15 0,28 8,22 TP-E6 240 360 180 1,10 0,28 10,27 Graphs were plotted using the parametres shown in the right side table. For oil graphs see separated sheet. Flow Rate Correction Factors Maximal Fresh Flow Rate Capacity: 340 l/min (215 l/min if sea water).this table means a typical performance of the shown units at given average process data of oil outlet temperature : 50ºC; Inlet Temperature: 25ºC, Viscosity of : 38Cst with SAE 30 type and 50ºC. Any other change in the chosen parametres could result in a different oil cooler selection. Temperature Correction Factors When temperature gap between oil outlet and water inlet exceeds the given 25ºC the following correction factors should be used: 10ºC: 0.4 / 15ºC: 0.6 / 20ºC: 0.8 / 30ºC: 1.2 / 35ºC: 1.4 / 40ºC: 1.6 (multiply KW by the suitable correction factor). For water rates other than 50% of the oil rate, the following correction factors should be used: 25%: 0.8 / 100%: 1.2 (multiply the rate by the suitable correction factor). Pressure Drop Graphs for primary and secondary circuits are available at our Technical Dept. Please consult your nearest PILAN distributor. 13

Pilan Hydraulic Coolers and Heat Exchangers Hydraulics Coolers - Series F PILAN Shell and Tube Heat Exchangers are designed in a three passes tube stack arrangement with cooling fluid inlet and outlet in opposite sides and counter current fluids. Tube stack is fully floating type thus thermal stresses are minimised while maintenance operations are eased. PILAN range of Industrial Shell & Tube Heat Exchangers are suitable for any sort of heat transfer fluids, heating or cooling process fluids. Its use is restricted to liquid phase fluids and material compatibility should be observed. MAWP: oil 14 bar, water 10 bar * MAWT: 120ºC (180ºC with VITON seals) * Testing Standard: BS6755 Stabillity Test performed at 20 bar, Sealing Leakage Test at 14 bar. Dimensions Model A B C D E-F Weight TP-F1 754 330 236 Ø278 3 47 TP-F2 900 476 382 Ø278 3 57 TP-F3 1.077 654 560 Ø278 3 68 TP-F4 1.280 856 762 Ø278 3 79 TP-F5 1.484 1.060 966 Ø278 3 91 TP-F6 1.790 1.364 1.270 Ø278 3 105 Pilan - is a trademark of Comeval Valve Systems Data subject to change without prior notice 14 Length Units expressed in mm, Diametres in Inches / Weight in Kgs General Arrangement Drawings pdf or Auto-Cad formats are available on request. Parts and Materials Part Name Material 1 Shell Aluminium /Bronze/Cast Iron 2 Tube Stack 2.1 Tubes Copper / Copper-Nickel / St. Steel 2.2 Tube plates Brass / Bronze 2.3 Baffles Aluminium 2.4 Welding Tin welded 60/40 3 End caps Brass / Bronze 4 Seals NBR / Viton 5 Cover screws Steel 6 Drain plugs Brass Remarked materials denote standard construction for Industrial Units. Performance Graphs Graphs were plotted using the parametres shown in the right side table. For oil graphs see separated sheet. Flow Rate Correction Factors Flow Rate Maximal Fresh Flow Rate Capacity: 800 l/min (500 l/min if sea water).this table means a typical performance of the shown units at given average process data of oil outlet temperature : 50ºC; Inlet Temperature: 25ºC, Viscosity of : 38Cst with SAE 30 type and 50ºC. Any other change in the chosen parametres could result in a different oil cooler selection. Temperature Correction Factors When temperature gap between oil outlet and water inlet exceeds the given 25ºC the following correction factors should be used: 10ºC: 0.4 / 15ºC: 0.6 / 20ºC: 0.8 / 30ºC: 1.2 / 35ºC: 1.4 / 40ºC: 1.6 (multiply KW by the suitable correction factor). For water rates other than 50% of the oil rate, the following correction factors should be used: 25%: 0.8 / 100%: 1.2 (multiply the rate by the suitable correction factor). Pressure Drop Graphs for primary and secondary circuits are available at our Technical Dept. Please consult your nearest PILAN distributor. Model Heat dissipated (kw) (l/ min) (l/min) Surface (m2) TP-F1 133 720 360 0,36 0,09 7,20 TP-F2 180 780 390 0,50 0,13 9,14 TP-F3 250 840 420 0,62 0,17 11,81 TP-F4 325 900 450 0,76 0,25 14,60 TP-F5 410 960 480 1 0,32 17,30 TP-F6 500 900 450 1,16 0,52 21,54

Pilan Hydraulic Coolers and Heat Exchangers Hydraulics Coolers - Series AM PILAN Shell and Tube Heat Exchangers are designed in a three passes tube stack arrangement with cooling fluid inlet and outlet in opposite sides and counter current fluids. Tube stack is fully floating type thus thermal stresses are minimised while maintenance operations are eased. PILAN range of Marine Shell & Tube Heat Exchangers are suitable for any sort of heat transfer fluids, heating or cooling process fluids. Its use is restricted to liquid phase fluids and material compatibility should be observed. MAWP: oil 14 bar, water 10 bar * MAWT: 120ºC (180ºC with VITON seals) * Testing Standard: BS6755 Stabillity Test performed at 20 bar, Sealing Leakage Test at 14 bar. Dimensions Model A B C D E-F Weight TP-A1M 195 72 38 Ø86 3/4 3 TP-A2M 263 138 103 Ø86 3/4 3,5 TP-A3M 349 225 189 Ø86 3/4 4 TP-A4M 448 326 288 Ø86 3/4 4,7 TP-A5M 576 450 415 Ø86 3/4 5,5 Length Units expressed in mm, Diametres in Inches / Weight in Kgs General Arrangement Drawings pdf or Auto-Cad formats are available on request. Parts and Materials Part Name Material 1 Shell Aluminium /Bronze/Cast Iron 2 Tube Stack 2.1 Tubes Copper-Nickel / St. Steel / Copper 2.2 Tube plates Brass / Bronze 2.3 Baffles Aluminium 2.4 Welding Tin welded 60/40 3 End caps Brass / Bronze 4 Seals NBR / Viton 5 Cover screws Steel 6 Drain plugs Brass Remarked materials denote standard construction for Marine Units. Performance Graphs Flow Rate Model Heat dissipated (kw) (l/ min) (l/min) Surface (m2) TP-A1M 3 30 15 0,10 0,02 0,13 TP-A2M 6 46 23 0,19 0,05 0,22 TP-A3M 9 56 28 0,36 0,09 0,32 TP-A4M 13 64 32 0,60 0,13 0,46 TP-A5M 16 56 28 0,56 0,12 0,68 Graphs were plotted using the parametres shown in the right side table. For oil graphs see separated sheet. Flow Rate Correction Factors Maximal Fresh Flow Rate Capacity: 50 l/min (35 l/min if sea water).this table means a typical performance of the shown units at given average process data of oil outlet temperature : 50ºC; Inlet Temperature: 25ºC, Viscosity of : 38Cst with SAE 30 type and 50ºC. Any other change in the chosen parametres could result in a different oil cooler selection. Temperature Correction Factors When temperature gap between oil outlet and water inlet exceeds the given 25ºC the following correction factors should be used: 10ºC: 0.4 / 15ºC: 0.6 / 20ºC: 0.8 / 30ºC: 1.2 / 35ºC: 1.4 / 40ºC: 1.6 (multiply KW by the suitable correction factor). For water rates other than 50% of the oil rate, the following correction factors should be used: 25%: 0.8 / 100%: 1.2 (multiply the rate by the suitable correction factor). Pressure Drop Graphs for primary and secondary circuits are available at our Technical Dept. Please consult your nearest PILAN distributor. 15

Pilan Hydraulic Coolers and Heat Exchangers Hydraulics Coolers - Series BM PILAN Shell and Tube Heat Exchangers are designed in a three passes tube stack arrangement with cooling fluid inlet and outlet in opposite sides and counter current fluids. Tube stack is fully floating type thus thermal stresses are minimised while maintenance operations are eased. PILAN range of Marine Shell & Tube Heat Exchangers are suitable for any sort of heat transfer fluids, heating or cooling process fluids. Its use is restricted to liquid phase fluids and material compatibility should be observed. MAWP: oil 14 bar, water 10 bar * MAWT: 120ºC (180ºC with VITON seals) * Testing Standard: BS6755 Stabillity Test performed at 20 bar, Sealing Leakage Test at 14 bar. Dimensions Model A B C D E-F Weight TP-B1M 273 123 109 Ø108 1 5 TP-B2M 355 205 191 Ø108 1 6 TP-B3M 452 302 289 Ø108 1 7 TP-B4M 587 437 425 Ø108 1 8,2 TP-B5M 730 580 566 Ø108 1 10 Length Units expressed in mm, Diametres in Inches / Weight in Kgs General Arrangement Drawings pdf or Auto-Cad formats are available on request. Parts and Materials Part Name Material 1 Shell Aluminium /Bronze/Cast Iron 2 Tube Stack 2.1 Tubes Copper-Nickel / St. Steel / Copper 2.2 Tube plates Brass / Bronze 2.3 Baffles Aluminium 2.4 Welding Tin welded 60/40 3 End caps Brass / Bronze 4 Seals NBR / Viton 5 Cover screws Steel 6 Drain plugs Brass Pilan - is a trademark of Comeval Valve Systems Data subject to change without prior notice Remarked materials denote standard construction for Marine Units. Performance Graphs Graphs were plotted using the parametres shown in the right side table. For oil graphs see separated sheet. Flow Rate Correction Factors Flow Rate Model Heat dissipated (kw) Maximal Fresh Flow Rate Capacity: 80 l/min (50 l/min if sea water).this table means a typical performance of the shown units at given average process data of oil outlet temperature : 50ºC; Inlet Temperature: 25ºC, Viscosity of : 38Cst with SAE 30 type and 50ºC. Any other change in the chosen parametres could result in a different oil cooler selection. Temperature Correction Factors When temperature gap between oil outlet and water inlet exceeds the given 25ºC the following correction factors should be used: 10ºC: 0.4 / 15ºC: 0.6 / 20ºC: 0.8 / 30ºC: 1.2 / 35ºC: 1.4 / 40ºC: 1.6 (multiply KW by the suitable correction factor). For water rates other than 50% of the oil rate, the following correction factors should be used: 25%: 0.8 / 100%: 1.2 (multiply the rate by the suitable correction factor). (l/ min) (l/min) Surface (m2) TP-B1M 8 66 33 0,16 0,02 0,33 TP-B2M 12 80 40 0,32 0,03 0,48 TP-B3M 18 104 52 0,96 0,07 0,66 TP-B4M 25 106 53 1 0,11 0,90 TP-B5M 29 98 49 1,04 0,14 1,16 16 Pressure Drop Graphs for primary and secondary circuits are available at our Technical Dept. Please consult your nearest PILAN distributor.

Pilan Hydraulic Coolers and Heat Exchangers Hydraulics Coolers - Series CM PILAN Shell and Tube Heat Exchangers are designed in a three passes tube stack arrangement with cooling fluid inlet and outlet in opposite sides and counter current fluids. Tube stack is fully floating type thus thermal stresses are minimised while maintenance operations are eased. PILAN range of Marine Shell & Tube Heat Exchangers are suitable for any sort of heat transfer fluids, heating or cooling process fluids. Its use is restricted to liquid phase fluids and material compatibility should be observed. MAWP: oil 14 bar, water 10 bar * MAWT: 120ºC (180ºC with VITON seals) * Testing Standard: BS6755 Stabillity Test performed at 20 bar, Sealing Leakage Test at 14 bar. Dimensions Model A B C D E-F Weight TP-C1M 372 182 93 Ø130 1 1/4 9 TP-C2M 472 287 193 Ø130 1 1/4 10 TP-C3M 600 415 320 Ø130 1 1/4 12,5 TP-C4M 744 557 465 Ø130 1 1/4 14,5 TP-C5M 922 737 643 Ø130 1 1/4 17,5 Length Units expressed in mm, Diametres in Inches / Weight in Kgs General Arrangement Drawings pdf or Auto-Cad formats are available on request. Parts and Materials Part Name Material 1 Shell Aluminium /Bronze/Cast Iron 2 Tube Stack 2.1 Tubes Copper-Nickel / St. Steel / Cooper 2.2 Tube plates Brass / Bronze 2.3 Baffles Aluminium 2.4 Welding Tin welded 60/40 3 End caps Brass / Bronze 4 Seals NBR / Viton 5 Cover screws Steel 6 Drain plugs Brass Remarked materials denote standard construction for Marine Units. Performance Graphs Flow Rate Model Heat dissipated (kw) (l/ min) (l/min) Surface (m2) TP-C1M 16 100 50 0,28 0,04 0,64 TP-C2M 26 120 60 0,55 0,07 0,90 TP-C3M 36 140 70 0,74 0,13 1,23 TP-C4M 48 160 80 1,06 0,17 1,60 TP-C5M 56 140 70 0,95 0,16 2,07 Graphs were plotted using the parametres shown in the right side table. For oil graphs see separated sheet. Flow Rate Correction Factors Maximal Fresh Flow Rate Capacity: 140 l/min (90 l/min if sea water).this table means a typical performance of the shown units at given average process data of oil outlet temperature : 50ºC; Inlet Temperature: 25ºC, Viscosity of : 38Cst with SAE 30 type and 50ºC. Any other change in the chosen parametres could result in a different oil cooler selection. Temperature Correction Factors When temperature gap between oil outlet and water inlet exceeds the given 25ºC the following correction factors should be used: 10ºC: 0.4 / 15ºC: 0.6 / 20ºC: 0.8 / 30ºC: 1.2 / 35ºC: 1.4 / 40ºC: 1.6 (multiply KW by the suitable correction factor). For water rates other than 50% of the oil rate, the following correction factors should be used: 25%: 0.8 / 100%: 1.2 (multiply the rate by the suitable correction factor). Pressure Drop Graphs for primary and secondary circuits are available at our Technical Dept. Please consult your nearest PILAN distributor. 17

Pilan Hydraulic Coolers and Heat Exchangers Hydraulics Coolers - Series DM Pilan - is a trademark of Comeval Valve Systems Data subject to change without prior notice PILAN Shell and Tube Heat Exchangers are designed in a three passes tube stack arrangement with cooling fluid inlet and outlet in opposite sides and counter current fluids. Tube stack is fully floating type thus thermal stresses are minimised while maintenance operations are eased. PILAN range of Marine Shell & Tube Heat Exchangers are suitable for any sort of heat transfer fluids, heating or cooling process fluids. Its use is restricted to liquid phase fluids and material compatibility should be observed. MAWP: oil 14 bar, water 10 bar * MAWT: 120ºC (180ºC with VITON seals) * Testing Standard: BS6755 Stabillity Test performed at 20 bar, Sealing Leakage Test at 14 bar. Dimensions Model A B C D E-F Weight TP-D1 505 270 109 Ø162 1 1/2 20 TP-D2 634 402 238 Ø162 1 1/2 24 TP-D3 780 546 384 Ø162 1 1/2 27 TP-D4 954 722 558 Ø162 1 1/2 32 TP-D5 1.160 928 764 Ø162 1 1/2 38 TP-D6 1.364 1.132 968 Ø162 1 1/2 45 Length Units expressed in mm, Diametres in Inches / Weight in Kgs General Arrangement Drawings pdf or Auto-Cad formats are available on request. Parts and Materials Part Name Material 1 Shell Aluminium /Bronze/Cast Iron 2 Tube Stack 2.1 Tubes Copper-Nickel / St. Steel / Copper 2.2 Tube plates Brass / Bronze 2.3 Baffles Aluminium 2.4 Welding Tin welded 60/40 3 End caps Brass / Bronze 4 Seals NBR / Viton 5 Cover screws Steel 6 Drain plugs Brass Remarked materials denote standard construction for Marine Units. Performance Graphs Graphs were plotted using the parametres shown in the right side table. For oil graphs see separated sheet. Flow Rate Correction Factors Flow Rate Model Heat dissipated (kw) Maximal Fresh Flow Rate Capacity: 190 l/min (110 l/min if sea water).this table means a typical performance of the shown units at given average process data of oil outlet temperature : 50ºC; Inlet Temperature: 25ºC, Viscosity of : 38Cst with SAE 30 type and 50ºC. Any other change in the chosen parametres could result in a different oil cooler selection. Temperature Correction Factors When temperature gap between oil outlet and water inlet exceeds the given 25ºC the following correction factors should be used: 10ºC: 0.4 / 15ºC: 0.6 / 20ºC: 0.8 / 30ºC: 1.2 / 35ºC: 1.4 / 40ºC: 1.6 (multiply KW by the suitable correction factor). For water rates other than 50% of the oil rate, the following correction factors should be used: 25%: 0.8 / 100%: 1.2 (multiply the rate by the suitable correction factor). (l/ min) (l/min) Surface (m2) TP-D1M 40 180 90 0,40 0,07 1,58 TP-D2M 52 200 100 0,55 0,09 2,14 TP-D3M 66 220 110 0,62 0,12 2,79 TP-D4M 84 240 120 0,80 0,16 3,57 TP-D5M 108 260 130 1 0,19 4,48 TP-D6M 120 240 120 0,96 0,21 5,38 18 Pressure Drop Graphs for primary and secondary circuits are available at our Technical Dept. Please consult your nearest PILAN distributor.

Pilan Hydraulic Coolers and Heat Exchangers Hydraulics Coolers - Series EM PILAN Shell and Tube Heat Exchangers are designed in a three passes tube stack arrangement with cooling fluid inlet and outlet in opposite sides and counter current fluids. Tube stack is fully floating type thus thermal stresses are minimised while maintenance operations are eased. PILAN range of Marine Shell & Tube Heat Exchangers are suitable for any sort of heat transfer fluids, heating or cooling process fluids. Its use is restricted to liquid phase fluids and material compatibility should be observed. MAWP: oil 14 bar, water 10 bar * MAWT: 120ºC (180ºC with VITON seals) * Testing Standard: BS6755 Stabillity Test performed at 20 bar, Sealing Leakage Test at 14 bar. Dimensions Model A B C D E-F Weight TP-E1M 675 372 239 Ø198 2 33 TP-E2M 816 513 380 Ø198 2 39 TP-E3M 998 696 560 Ø198 2 45 TP-E4M 1.204 901 766 Ø198 2 54 TP-E5M 1.408 1.102 968 Ø198 2 64 TP-E6M 1.712 1.406 1.272 Ø198 2 74 Length Units expressed in mm, Diametres in Inches / Weight in Kgs General Arrangement Drawings pdf or Auto-Cad formats are available on request. Parts and Materials Part Name Material 1 Shell Aluminium /Bronze/Cast Iron 2 Tube Stack 2.1 Tubes Copper-Nickel / St. Steel / Copper 2.2 Tube plates Brass / Bronze 2.3 Baffles Aluminium 2.4 Welding Tin welded 60/40 3 End caps Brass / Bronze 4 Seals NBR / Viton 5 Cover screws Steel 6 Drain plugs Brass Remarked materials denote standard construction for Marine Units. Performance Graphs Graphs were plotted using the parametres shown in the right side table. For oil graphs see separated sheet. Flow Rate Correction Factors Flow Rate Model Heat dissipated (kw) Maximal Fresh Flow Rate Capacity: 340 l/min (215 l/min if sea water).this table means a typical performance of the shown units at given average process data of oil outlet temperature : 50ºC; Inlet Temperature: 25ºC, Viscosity of : 38Cst with SAE 30 type and 50ºC. Any other change in the chosen parametres could result in a different oil cooler selection. Temperature Correction Factors When temperature gap between oil outlet and water inlet exceeds the given 25ºC the following correction factors should be used: 10ºC: 0.4 / 15ºC: 0.6 / 20ºC: 0.8 / 30ºC: 1.2 / 35ºC: 1.4 / 40ºC: 1.6 (multiply KW by the suitable correction factor). For water rates other than 50% of the oil rate, the following correction factors should be used: 25%: 0.8 / 100%: 1.2 (multiply the rate by the suitable correction factor). (l/ min) (l/min) Surface (m2) TP-E1M 76 320 160 0,44 0,09 3,27 TP-E2M 106 360 180 0,64 0,13 4,24 TP-E3M 134 400 200 0,90 0,20 5,45 TP-E4M 175 420 210 1,10 0,25 6,82 TP-E5M 205 400 200 1,15 0,28 8,22 TP-E6M 240 360 180 1,10 0,28 10,27 Pressure Drop Graphs for primary and secondary circuits are available at our Technical Dept. Please consult your nearest PILAN distributor. 19

Pilan Hydraulic Coolers and Heat Exchangers Hydraulics Coolers - Series FM Pilan - is a trademark of Comeval Valve Systems Data subject to change without prior notice PILAN Shell and Tube Heat Exchangers are designed in a three passes tube stack arrangement with cooling fluid inlet and outlet in opposite sides and counter current fluids. Tube stack is fully floating type thus thermal stresses are minimised while maintenance operations are eased. PILAN range of Marine Shell & Tube Heat Exchangers are suitable for any sort of heat transfer fluids, heating or cooling process fluids. Its use is restricted to liquid phase fluids and material compatibility should be observed. MAWP: oil 14 bar, water 10 bar * MAWT: 120ºC (180ºC with VITON seals) * Testing Standard: BS6755 Stabillity Test performed at 20 bar, Sealing Leakage Test at 14 bar. Dimensions Model A B C D E-F Weight TP-F1M 754 330 236 Ø278 3 47 TP-F2M 900 476 382 Ø278 3 57 TP-F3M 1.077 654 560 Ø278 3 68 TP-F4M 1.280 856 762 Ø278 3 79 TP-F5M 1.484 1.060 966 Ø278 3 91 TP-F6M 1.790 1.364 1.270 Ø278 3 105 Length Units expressed in mm, Diametres in Inches / Weight in Kgs General Arrangement Drawings pdf or Auto-Cad formats are available on request. Parts and Materials Part Name Material 1 Shell Aluminium /Bronze/Cast Iron 2 Tube Stack 2.1 Tubes Copper-Nickel / St. Steel / Copper 2.2 Tube plates Brass / Bronze 2.3 Baffles Aluminium 2.4 Welding Tin welded 60/40 3 End caps Brass / Bronze 4 Seals NBR / Viton 5 Cover screws Steel 6 Drain plugs Brass Remarked materials denote standard construction for Marine Units. Performance Graphs Graphs were plotted using the parametres shown in the right side table. For oil graphs see separated sheet. Flow Rate Correction Factors Flow Rate Model Heat dissipated (kw) Maximal Fresh Flow Rate Capacity: 800 l/min (500 l/min if sea water).this table means a typical performance of the shown units at given average process data of oil outlet temperature : 50ºC; Inlet Temperature: 25ºC, Viscosity of : 38Cst with SAE 30 type and 50ºC. Any other change in the chosen parametres could result in a different oil cooler selection. Temperature Correction Factors When temperature gap between oil outlet and water inlet exceeds the given 25ºC the following correction factors should be used: 10ºC: 0.4 / 15ºC: 0.6 / 20ºC: 0.8 / 30ºC: 1.2 / 35ºC: 1.4 / 40ºC: 1.6 (multiply KW by the suitable correction factor). For water rates other than 50% of the oil rate, the following correction factors should be used: 25%: 0.8 / 100%: 1.2 (multiply the rate by the suitable correction factor). (l/ min) (l/min) Surface (m2) TP-F1M 133 720 360 0,36 0,09 7,20 TP-F2M 180 780 390 0,50 0,13 9,14 TP-F3M 250 840 420 0,62 0,17 11,81 TP-F4M 325 900 450 0,76 0,25 14,60 TP-F5M 410 960 480 1 0,32 17,30 TP-F6M 500 900 450 1,16 0,52 21,54 20 Pressure Drop Graphs for primary and secondary circuits are available at our Technical Dept. Please consult your nearest PILAN distributor.

Pilan Hydraulic Coolers and Heat Exchangers 3 Passes Design Shell & Tube Heat Exchangers Pressure Drop Data Sheet Series A / AM Series D / DM Series B / BM Series E / EM Series C / CM Series F / FM 21

Moulding the success. Pilan www.comeval.es