Bulletin 1494V Variable Depth Disconnect Switch Installation Instructions (Cat 1494V-DS400; -DSX400 - Series D)

Similar documents
Bulletin 1494C Cable Operated Disconnect Switch Kit (400A) Installation Instructions (Cat 1494C- _ Series 2 : 400A)

Table of Contents. Quick Installation Guide 2 - Disconnect Switch Installation - Disconnect Handle Installation - Cutting Connecting Rod

Bulletin 1494C Cable Operated Disconnect Switch Kit (600A) Installation Instructions (Cat 1494C- _ Series 2 : 600A)

Bulletin 1494V Variable Depth, Flange Operated Disconnect Switch Kits for 400 and 600 Amperes (Series A) Switches

Installation Instructions

PRODUCT PROFILE VARIABLE-DEPTH, FLANGE- MOUNTED DISCONNECT SWITCHES A BULLETIN 1494V

Cable-Operated Disconnect Switches. Accessories

PRODUCT PROFILE 1494C CABLE-OPERATED, FLANGE-MOUNTED DISCONNECT SWITCHES

Bulletin 1494F Fixed-Depth Flange-Mounted Disconnect Switches. Selection Guide

Bulletin 1494V Variable Depth, Flange Operated Circuit Breaker Kits for 125A, 150A 250A and 400A Frame Sizes

Bulletin 1494V Variable-Depth Flange-Mounted Circuit Breaker Operating Mechanism

Switch Base Replacement Instructions 3-Pole, 60 AMP, Fusible, w Neutral, Visible-Blade, Heavy Duty Safety Switches

Switch Base Replacement Instructions 3-Pole, 60 AMP, Fusible, Heavy Duty Safety Switches

Bulletin 1494V Variable Depth Flange-Mounted Disconnect Switches. Bulletin 1494F Fixed-Depth Flange-Mounted Disconnect Switches

CCP2-FLR1-21_ flange-rod operating mechanism

600V, Non-Fusible, (3-Pole, 3 Phase)

Bulletin 1494F 30A, 60A, 100A Fixed-Depth Disconnect Switch (Cat 1494F-N30; 1494F-N60; 1494F-N100; Series C)

OPERATOR ADAPTER A21ABA

SIRCO UL98 Load break switches standards UL and CSA 100 to 1200 A

Installation Instructions for Replacement Mechanism Kit

Disconnect Switches Type VBII (30-600A) with Flange Mounted Operating Handle

Camaro/Trans Am V3 T6 Kit Installation Instructions

Bulletin 1494M Fixed Depth Remote Operated Disconnect Switches Renewal Parts

Installation Instructions for Type SM Safety Handle Mechanism for L-Frame Series C Circuit Breakers and Molded Case Switches

SIRCO UL98 Non-fusible switches standards UL and CSA 100 to 1200 A

OPERATOR ADAPTER ABF

Bulletin 1494D Fixed-Depth Flange-Mounted Circuit Breakers

IMPORTANT WARRANTY & INSTALLATION INSTRUCTIONS ATTACHED

PARTS TOOLS. Set Screw. Washer (2) Blue Bushing (2) Black Bushing (2) B&M Short Throw Shifter. Jam Nut Grease. Retaining Ring (2) Insert (2)

Flange Mounted Disconnect Switch. Installation Instructions. Item: I.L. No A00 1 / 12 VBFS364F VBNFS361F VBNFS362F VBNFS363F VBNFS364F

EXTERNAL DISCONNECT ENCLOSURE INSTALL

Cat. No. 194R-J Note: Your order must include 1) Cat. No. of disconnect switch, 2) shaft, 3) handle, and 4) any accessories.

USER MANUAL Bulletin 1512A 400A One-High Cabinet Standard and Arc-Resistant Enclosure

OPERATOR ADAPTER ABBSV

TOYOTA FJ CRUISER AIR DAM/LIGHT BAR Preparation

Load Break Disconnect Switches FSLBS

UL/CSA Non-fused Disconnect Switches

<THESE INSTRUCTIONS MUST BE GIVEN TO THE END USER> B&W

Feeder Circuit Breaker Units Secure Support Pan and Change Door Latch

Digitrip Retrofit System for ITE K-3000, K-3000 S, K-4000 and K-4000 S Breakers

Non-Fused Load Break Switches FSSC, SX, SXDC, SC

Installation Instructions

SEQUESTR. External Disconnect Enclosure. Rev. C 2013 Pentair Equipment Protection PH hoffmanonline.com P/N

Big performance in a small package

Installation Instructions

Non-Fused Load Break Switches FSSC, SX, SXDC, SC

2-row and All-row systems included.

Instructions for Installation, Operation and Maintenance of: "WSRD" Interlocked Receptacles 30, 60 & 100 Ampere

Installation Instructions

Air Commander Part No , with air Part No , without air

TOYOTA SIENNA TRAILER WIRE HARNESS Preparation

Registers for spiral ducts

Installation Instructions

GE Industrial Solutions. Limitamp * AR. Arc Resistant Medium Voltage Motor Control. Installation Guide

IMPORTANT WARRANTY & INSTALLATION INSTRUCTIONS ATTACHED

UL Enclosed Disconnect Switches (Fused and Non-Fused)

Installation Instructions

Plow Partner Mounting Kit M

Universal Mounting Kit #0820

Enclosure for AMP1 Series Energy Meters with Swing Panel Kit

1E EJB Junction Boxes Cl. I, Div. 1 and 2, Groups B, C, D

INSTALLATION INSTRUCTIONS AM rev. A

<THESE INSTRUCTIONS MUST BE GIVEN TO THE END USER> B&W Trailer Hitches 1216 Hawaii Rd / PO Box 186 Humboldt, KS P: F:

Product Guide. NEMA pump controls.

<THESE INSTRUCTIONS MUST BE GIVEN TO THE END USER> B&W

Milwaukee's Electric Actuator Installation, Operation & Maintenance Manual

NISSAN #2744. Gross Trailer Weight (Maximum)...16,000 lbs. Vertical Load Weight (Max. Pin Weight)...4,000 lbs. SYSTEM TOW CAPACITY

PERFORMANCE SUSPENSION PARTS

<THESE INSTRUCTIONS MUST BE GIVEN TO THE END USER> B&W

INSTALLATION INSTRUCTIONS AND OPERATION MANUAL

FUSIBLE DISCONNECT SWITCHES

<THESE INSTRUCTIONS MUST BE GIVEN TO THE END USER> B&W

NEVER STOP CORRUGATE OPENER

FORD SuperRail Mounting Kit #3111

<THESE INSTRUCTIONS MUST BE GIVEN TO THE END USER> B&W Trailer Hitches 1216 Hawaii Rd / PO Box 186 Humboldt, KS P: F:

AE012 Enclosure for E5x Series Energy Meters With Swing Panel Kit Product Overview

Operation and Maintenance Manual

R. Manually Operated: Standard closure to be manually operated push up, pull down with removable retrieval rod as standard. The effort to raise or low

<THESE INSTRUCTIONS MUST BE GIVEN TO THE END USER> B&W Trailer Hitches 1216 Hawaii Rd / PO Box 186 Humboldt, KS P: F:

Safety 14 ga. Welded Plastic Bin Security Fire Resistant Gas Cylinder

Prevents Unscheduled Truck Departures

SPEEDFAX TM 2011 Disconnect Switches Contents

Installation Instructions

35-kV Safefront Mini-Switch Source Isolated Pad-Mounted Switchgear 50 Amp (Max) Clip-Mounted Current-Limiting Fuses

UL Class J and CSA HRCI-J Fuses ➋. obsolete. CSA HRCII-C Fuses. Maximum Horsepower ➊

IMPORTANT WARRANTY & INSTALLATION INSTRUCTIONS ATTACHED

Non-Fused Load Break Switches FSSC, SX, SXDC, SC

w w w. h d o n l i n e s h o p. d e ROAD TECH QUEST GLOBAL POSITIONING SYSTEM (GPS) MOUNTING KIT GENERAL INSTALLATION -J03554 REV.

VD0C06N908C July 1998 Raleigh, NC, USA. Instruction Bulletin ALTIVAR 66, ALTIVAR 58, ALTIVAR 18. Dynamic Braking Resistor Kit User s Manual

Please reference the attached document for information regarding the installation of Utility Side Skirts (USS-160) on Dry Freight Trailers.

Non-Fused Load Break Switches FSSC, SX, SXDC, SC

Low Voltage Products. Catalog. Flange Handle Operated Disconnect Switches. Non Fusible 30A A Fusible 30A - 800A

Installation Instructions

Installation Instructions

Standard Product Low Profile Type 12 One-Door Disconnect Enclosures

Disconnect Enclosures

Models. Save This Manual For Future Reference. International Comfort Products Corporation (USA) Lewisburg, TN USA LP1 5/16/

SEQUESTR. External Disconnect Enclosure. Rev. A 2014 Pentair Equipment Protection PH hoffmanonline.com P/N

* * E996L Series. E996L for Rim/Vertical. E996L for Mortise CAUTION

LIGHT DUTY ROLL UP DOOR

Transcription:

Bulletin 494V Variable Depth Disconnect Switch Installation Instructions (Cat 494V-DS400; -DSX400 - Series D) ATTENTION: To prevent electrical shock, disconnect from power source before installing or servicing. Follow NFPA 70E requirements. Install in suitable enclosure. Keep free from contaminants. ATTENTION: The following procedures are critical to the proper operation of the disconnect handle and switch. Failure to follow these steps can result in damage to the equipment and/or serious injury or death to the operator. Table of Contents Page Quick Installation Guide - Disconnect Switch Installation - Disconnect Handle Installation - Cutting Connecting Rod Quick Installation Guide (continued) - Connecting Rod Installation Connecting Rod Adjustment Procedure 4 Enclosure Without Handle Cutout 5 - Locate Handle - Drill Handle Holes Door Catch Mounting Bracket Installation 6 Disconnect Switch Installation 7 - Locate Disconnect Switch - Install Disconnect Switch - Assemble and Install Line Terminal Guard Trailer Fuse Block Installation 8 Phase Barrier Replacement and Terminal Adapter Installation 9 Fuse Clip Installation 0 Bulletin 494V Disconnect Switch Kit Bulletin 494V Disconnect Switch Kit Optional Accessory List

QUICK INSTALLATION GUIDE Disconnect Switch Installation (Right hand installation shown. For left hand installation follow similar procedure.) Use template D to locate handle holes on mounting plate. 5 Overlay template E (400 A) over D. 7 Install disconnect switch. 4 5 - / TOP 5 TOP HANDLE HOLE MEASURE TO INSIDE OF THE TOP OF ENCLOSURE HOLD FLUSH TO INSIDE OF ENCLOSURE Switch Mounting Holes BOTT Center punch and drill (4) /" holes for thread forming (TAP-TITE) screws provided with switch 6-/ TAPE D MEASURE TO INSIDE OF THE TOP OF ENCLOSURE HOLD FLUSH TO INSIDE OF ENCLOSURE BOTTOM HANDLE HOLE MEASURE TO INSIDE OF THE TOP OF ENCLOSURE HOLD FLUSH TO INSIDE OF ENCLOSURE D TOP BOTT E 405-58-0 () Printed in U.S.A. A 4 - /4 Disconnect Switch Hole Location Template () RIGHT Hand Installation (Use opposite side for left hand installation) 6 Center punch and drill (4) holes for 5/6-8 thread forming screws provided with switch. 9/" Dia. 90-0 lb-in Disconnect Handle Installation Install gasket. Install handle and spring bracket. Install defeater lever. 60-80 lb-in IMPORTANT: Apply grease to O-Ring to retain into handle groove. 7- lb-in Cutting Connecting Rod (Cut () Connecting Rods; first rod connects the handle to the switch, second rod provides stiffening for the enclosure flange) Measure working depth of enclosure. Measure, mark and Remove burrs. cut () connecting rods. Mounting Plate Enclosure Working Depth (Inside Flange of Enclosure to Mounting Plate) N N minus -/4" ()

QUICK INSTALLATION GUIDE (CONTINUED) 4 Connecting Rod Installation First rod connects the handle to the switch Verify that disconnect switch and handle are in "OFF" position. (Switch blades will be visible) Pull rod up and verify if rod is touching bottom of spring bracket. (If not, rotate rod until it touches spring bracket) Drive Bar 4 Rotate connecting rod into drive bar 6 turns. Zero Clearance Connecting Rod Hitch Pin 6 7 5 Primary Link Second rod provides stiffening for the enclosure flange 8 9 50-00 lb-in 0 ATTENTION: CHECK FOR PROPER OPERATION ()

Connecting Rod Adjustment Procedure Drive Bar Hitch Pin Connecting Rod Primary Link "ON" Position ➊ Move disconnect handle to the "ON" position. ➋ If switch does not fully close, return handle to "OFF" position. ➌ Remove link spring hitch pin and disengage the connectiong rod from the primary link. ➍ Turn connecting rod counter-clockwise ( or more) full turns. ➎ Re-engage connecting rod in primary link of handle, insert hitch pin and re-test ➏ Repeat ➊ - ➎ as necessary. ➐ Re-install link spring "OFF" Position ➊ Move disconnect handle to the "OFF" position. ➋ If switch does not fully open, return handle to "ON" position. ➌ Remove hitch pin and link spring, then disengage the connectiong rod from the primary link. ➍ Turn connecting rod clockwise ( or more) full turns. ➎ Re-engage connecting rod in primary link of handle, insert hitch pin and re-test. ➏ Repeat ➊ - ➎ as necessary. ➐ Re-install link spring (4)

Enclosure without Handle Cutout Enclosures with a Flange Thickness less than /6" use dimensions below to install disconnect handle. Enclosures with a Flange Thickness /6" and greater use dimensions in Alternate Mounting Kit 494V-H6 to install disconnect handle. Locate Handle - /8" Max. - /8" Max. - /8" Min. - /8" Min. 4 - /8" Min. 4 - /8" Min. Top Handle Hole Right Hand Flange Left Hand Flange Drill Handle Holes Top Handle Hole ().8 Dia. Holes 5/6" Square corners or up to /4" radius 5 - /" 6 - /" /" /4" (5)

Door Catch Bracket Installation Right hand installation shown (for left hand installation follow similar procedures) Door Catch Mounting Bracket: Provided with projections for welding. Projections can also be used as a guide for drilling holes. Can be used as a template to drill corresponding holes in the enclosure door. User to supply the hardware for fastening the bracket. Fasteners must provide the degree of ingress protection for the environmental rating of the enclosure. The bracket hardware must be inaccessible to unauthorized personnel. Dimension K (/4" to ") When using large disconnect handle kit only (494F-M or -S), use door catch provided with handle kit. When using large disconnect handle kit and small door hardware kits (494V-L, -LL, -L or -LL), use door catch provided with door hardware kit. Dimension K (-/8" to -/8") When using large disconnect handle kit only (494F-M or -S), use door catch (4049-080-0) which can be ordered from factory. When using large disconnect handle kit and large door hardware kits (494V-L or -LL), use door catch provided with door hardware kit. Door Catch Mounting Bracket Top TOP VIEW - 7 lb-in Door Catch Enclosure Door Door Catch Mounting Bracket Flange Thickness K Door Catch D C B Enclosure Base NEMA SIZE Enclosure Dimensions A (min) B (min) C (max) D E 4 - /8" - /8" - /8" - 5/8" - /4" C B B C A A E E Top Handle Hole Door Catch Mounting Bracket D D Door Catch Mounting Bracket Right Hand Flange (6) Left Hand Flange

Disconnect Switch Installation Locate Disconnect Switch CC AA EE AA CC FF FF BB BB DD DD HH Top Handle Hole HH GG GG Right Hand Flange Left Hand Flange Panel Mounting Dimensions Switch Size AA BB CC DD EE FF GG HH (4 Mounting Plate Holes) 5" 5-/" " " 5" 9/" Dia. 4-/4" -/8" Install Disconnect Switch Assemble and Install Line Terminal Guard LINE TERMINAL GUARD 90-0 lb-in LINE TERMINAL GUARD (7)

Trailer Fuse Block Installation (Switch Rating ) Trailer Fuse Block Location Note: Not required for non-fusible disconnect switch applications. 00 00 00 00 400 400 400 400 400 Amp Trailer Fuse Block (494V-FS400) Fuse Torque (lb-in) A Fuse Lug to Block Terminal Amps Voltage Class Fuse Clip 50 600 600 600 50 600 600 600 H/R H/R J HRCII-C H/R H/R J HRCII-C 7-/6" 0-/6" 6-/8" 6-/8" 8-/6" -/6" 7-/6" 8-/6" 6- -7 90-0 Wire into Lug 75-00 75-05 A 4 - /4" Install Trailer Fuse Block 90-0 lb-in (8)

Phase Barrier Replacement Kit (Switch Rating ) 494F-PH5 0-0 lb-in 4 CLICK Terminal Adapter Installation - Conversion from Fusible to Non-Fusible (Switch Rating ) 90-0 lb-in 75-00 lb-in 5-50 lb-in (9)

Fuse Clip Installation (Switch Rating ) Switch for Right Hand Mechanism Switch for Left Hand Mechanism 00A Fuse Clips Fuse Clips 6 - lb-in - 7 lb-in 00A Fuse Clips Fuse Clips 6 - lb-in - 7 lb-in Switch for Right Hand Mechanism Switch for Left Hand Mechanism 00A Fuse Clips Fuse Clips - 7 lb-in 40-55 lb-in 00A Fuse Clips Fuse Clips - 7 lb-in 40-55 lb-in (0)

Bulletin 494V Disconnect Switch Kit Disconnect Kit Catalog Number and Description Switch with Right Hand Mechanism 494V-DS400 () Switch Switch with Left Hand Mechanism 494V-DSX400 () Handle 494F-M (7-/" Painted Metal) ( / 600A) 494F-S (7-/" Stainless Steel) ( / 600A) Connecting Rod 494V-RB (Standard) () Enclosure Working Depth: 9-/" to 0" 494V-RB4 (Extended)() Enclosure Working Depth: 9-/" to " Fuse Block 494V-FS400 () Fuse Clips 40-N45 (Class H, J, 00A-50V, 00A-600V) 40-N46 (Class H, J, -50V, -600V) 40-N54 (Class R, 00A-50V, 00A-600V) 40-N55 (Class R, -50V, -600V) ()

Bulletin 494V Disconnect Switch Optional Accessory List Optional Accessories (Installation Instructions Included with Accessory Kits) Electrical Interlock Catalog Number and Description Switch with Right Hand Mechanism 495-N4 (-N.O./N.C.) 495-N44 (-N.O./N.C.) Switch with Left Hand Mechanism 495-N4 (-N.O./N.C.) 495-N4 (-N.O./N.C.) Auxiliary Contact 495-N8 (-N.O.) () 495-N9 (-N.C.) () Auxiliary Contact Adapter Kit 495-N5 () (Required only for Switch with Left Hand Mechanism) Lug Connectors 494R-N4 (CU Wire Size - #/0-50 MCM) () 494R-N5 (CU Wire Size #4.. 500 MCM) () Phase Barrier 494F-PH5 () Switch Rating Fuse Class Fuse Clip Rating 50V 600V Cat No. Fuse Cover with Door Non-Fusible ---- ---- Non-Fusible ---- ---- H, J, R H, J, R 00A 00A 00A 00A 495-N68➀ 495-N6➁ 495-N68➀ 495-N6➁ ➀ Switch with right hand mechanism ➁ Switch with left hand mechanism 405-54-0 () Printed in U.S.A.