PV4 - PIV6. Submersible multistage centrifugal electro-pumps. Installation and maintenance. This manual is to be given to the end user

Similar documents
Monocellular centrifugal electro-pumps

3946 en / a. This manual is to be given to. the end user. HPM x44. A.C. motor. Installation and maintenance

COMPABLOC. Cb Cb Cb 1504 Installation and maintenance. These instructions should be given to the end user GN

Operating Instructions

This manual is to be given to. the end user P.M.G. / ALTERNATORS. Installation and maintenance

INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS

230V 60Hz LINE FUSES AM CLASS:

Installation guide. Mb 3101, Mb Drive systems. Part number: 2910 en / p

VEM motors Thurm GmbH

VADA - V75-S PRODUCT OVERVIEW CONSTRUCTION USAGE LIMITATIONS MOTOR WARRANTY

INSTALLATION AND OPERATING MANUAL. TM Series Multi-stage Pump

VERTICAL MULTI-STAGE CENTRIFUGAL PUMPS

VADA - V60-J PRODUCT OVERVIEW CONSTRUCTION MOTOR USAGE LIMITATIONS WARRANTY

VERTICAL MULTI-STAGES CENTRIFUGAL PUMPS

Medium and high pressure pumps

R231 A.V.R. Installation and maintenance R 231. This manual is to be given to. the end user. Armature 6- Field. Slow-blow fuse 250V 8 A

Centrifugal Pumps (Part Nos. PS2SS PS73SS) PS2SS

SELF PRIMING CHEMICAL SERVICE PUMPS

Operating and Installation Instructions Diaphragm Vacuum Pumps and Compressors

Company name: GRUDNFOS VisMin Created by: Kimmboy Ancis Phone: Date: 13/03/2017

PROMAG SR SERIES SEAL-LESS CENTRIFUGAL PUMPS

Installation, Operating, Maintenance and Safety Instructions for CW332 Pressurised water system for boats 24 volt d.c.

Instruction for RBP250-3 and RBP300-3

Service Handbook HD /97

Series Base mounted pump. Installation and operating instructions

SERIES PC INSTRUCTION AND OPERATION MANUAL

OPERATION & MAINTENANCE INSTRUCTIONS

Compact System NRGS 11-2 NRGS Original Installation Instructions English

THREE PHASE AND SINGLE PHASE ASYNCHRONOUS ELECTRIC MOTORS OPERATION AND MAINTENANCE BOOKLET Rev

BAH series Use and Maintenance Manual

DulcoFlex Peristaltic Pump: DFB13B

TPHK Series Immersible Pump

Series Base mounted pump. Installation and operating instructions

SLR / SLR-S/N. Instruction Manual. Walrus America Inc

Maintenance Guide COMPABLOC Reference: 5060 en / c

CM15-1 A-R-I-V-AQQV C-A-A-N

Heavy duty slurry pumps

Installation and maintenance guide LSK. D.C. motors. Reference: 5703 en / a

HOT WASHER MODEL NO: KING 125 OPERATION & MAINTENANCE INSTRUCTIONS PART NO: LS1009

POND PUMP Model Nos:SPP3 & SPP6 0200

PLSES 4500 IMfinity Platform. IP23 high-speed induction motors Industrial refrigeration Variable speed Frame size 225 to to 480 kw

3947 en / b

ASYNCHRONOUS MOTORS THREE-PHASE MOTORS SINGLE-PHASE MOTORS BRAKE MOTORS INSTRUCCIONES DE SERVICIO OPERATING INSTRUCTIONS 2016

UNPACKING SAFETY GUIDELINES GENERAL SAFETY INFORMATION. Operating Instructions & Maintenance Manual

OPERATION & MAINTENANCE INSTRUCTIONS

Instruction Manual. Sewage lifting station compli 300

H.S. MACHINERY RING COMPRESSORS

This manual presents installation, servicing, troubleshooting, and maintenance for M PUMPS CM MAG-M SERIES Information that may be required regarding

Instruction manual. Installation requirements. Power Take-Off. Pump mounting: Spline shaft DIN 5462 / ISO 14. Mounting flange ISO 7653-D.

Immersion Pumps PRG sealless

FLÄKTGROUP PM-MOTOR WITH INTEGRATED FC 106 FREQUENCY CONVERTER

Appendix: Safety and application notes for... 15

Operation Manual Model: PPSSS Submersible Slurry Pump

USER MANUAL. TSK and TSK V.

CPLS Drip-proof 3-phase induction motors

Model and Series 115 VAC INDUSTRIAL DIAPHRAGM PUMPS. PumpAgents.com - buy pumps and parts online INDUSTRIAL DIAPHRAGM PUMPS

Chapter 5 Part B: Ignition system - transistorised type

Installation and maintenance CPLS. Drip-proof 3-phase induction motors. Part number: 4240 en / c

M Series Condensate Recovery Unit

CM1-5 S-R-I-E-AQQE C-A-A-N

CM1-3 S-R-I-E-AQQE C-A-A-N

INSTRUCTION MANUAL INDUSTRIAL PERISTALTIC PUMPS MODEL RBT-70

Contents. Overview. Safety Instructions. Before Installation. Installation. Operation. Maintenance. Replacement Parts. System Specifications 8 01

Click on Warman Logo to go back to Menu WARMAN PUMPS ASSEMBLY, OPERATING AND MAINTENANCE INSTRUCTIONS PART 2Q SLURRY JET PUMPS TYPES JPC AND JPH PC2Q

Mb 3101, Mb 2000, Mb IA(W)

CM1-8 A-R-I-E-AQQE F-A-A-N

CM25-1 A-R-G-E-AQQE C-A-A-N

Owners Manual: - Pumps

Operating Instruction

Heavy duty slurry pumps

SUBMERSIBLE DIRTY WATER PUMP

User Manual Rittal PMC UPS 6kVA

250W PUDDLE PUMP WITH AUTO SENSOR MODEL NO: PSP105

Matala. VersiFlow Series. Instruction and Maintenance Manual

VT Oil-Free Range Operators Handbook

WARMAN PUMPS ASSEMBLY, OPERATING AND MAINTENANCE INSTRUCTIONS PART 2C SERIES A SOLUTION PUMPS TYPE S AND SH PC2C

INSTRUCTION MANUAL FOR THE CLINICAL 50 CENTRIFUGE

8000 / 10,000 / 12,000

TPHK Series Immersible Pump

PROCESS PUMPS (INDIA) PVT LTD

Installation, Operation and Maintenance Manual. EVC Controller (from February 2007)

CM3-6 A-R-G-E-AQQE C-A-A-N

A Series 50HZ. A - Series. Vertical Multistage Centrifugal in-line Pumps AVC/AVI/AVS ISO-9001

These installation and maintenance instructions must be read in full and completely understood before the installation!

Butterfly valves Figure 56 Installation & Maintenance Instructions

Set 2 Mini Pust APB50B

230V DIESEL FUEL TRANSFER PUMP MODEL NO: DFT230

NK /310A2F1AE-SBAQE

Installation Operation & Maintenance Manual. Oil-Free (Dry) Rotary Vane Vacuum Pump Systems

PUMP SCPD 56/26 DIN BY-PASS

CM1-6 A-R-I-E-AQQE F-A-A-N

Installation Operation Maintenance. LSSN Butterfly Valve AGA Approved 50MM - 150MM. QAD#IM6055.REVA

INSTALLATION AND OPERATING INSTRUCTIONS

NEOTECHA NTB-NTC BALL VALVES INSTALLATION AND MAINTENANCE INSTRUCTIONS

Installation Vertical Pump: Installation 'CM' and 'CDM' Style: Operation:

OWNERS MANUAL ECODIVER

ESE Series Cast Iron Sewage Pumps

Table of Contents. 1. Model Designation And Unit Models Guide Specifications Technical Data Performance Data 10

INTRODUCTION GENERAL GUIDELINES ATTACHING THE DRIVE PARTS

CGA CXA VGA VXA CG-PRC006-E4

Transcription:

Réf. 3483 GB - 4.33/a - 09.2001 This manual is to be given to the end user PV4 - PIV6 Submersible multistage centrifugal Installation and maintenance

PV4 - PIV6 1 - GENERAL PV4 and PIV6 series should be installed in accordance with the instructions in this manual. They must not be used in operating conditions other than those indicated in this document. Should these instructions not be adhered to, or any modification be made to the equipment, without the agreement of LEROY-SOMER, the guarantee will be invalidated. LEROY-SOMER accepts no responsibility if the instructions contained in this document have not been followed. This manual does not take account of any existing safety recommendations and regulations which may be in force where the equipment is installed. It is the responsibility of the user to ensure that these are applied and followed. 2 - USE The PV4 and PIV6 series multistage centrifugal electropumps are designed to pump water, oil or any other nonexplosive clear liquids which are compatible with the material with which the pump is made. For any other liquid: please consult LEROY-SOMER. maximum content of solid particles in suspension: 200 g/m 3 maximum viscosity of pumped liquid: 20 centistokes or 3 Engler with standard pump 75 centistokes or 10 Engler with pump with an oversized motor maximum temperature of pumped liquid: 70 C for hydraulic elements made of SAN (styroacrylo-nitrile) on PV4 pumps 90 C for hydraulic elements made of PEI (polyetherimide) on PV4 pumps and for PIV6 pumps minimum temperature of liquid conveyed: - 10 C maximum ambient temperature: 40 C maximum duty pressure of the pump (on lift): 10 bars on PV4 pumps with thermoplastic delivery head 20 bars on PV4 pumps with metal delivery head 25 bars on PIV6 pumps density of pumped liquid = 1 3.2 - Electrical characteristics Mot 3 ~ LS 80 N 820497EJ004 kg IP 55 I.cl F C 40 S S 1 V Hz min -1 kw cos ϕ A 230 50 2830 1,1 0,82 4,50 Y 400 50 2830 1,1 0,82 2,60 240 50 2850 1,1 0,78 4,50 Y 415 50 2850 1,1 0,78 2,60 D.000 LEROY-SOMER motors Rated current Power factor Rated power Rotation speed Frequency Supply voltage Connection Type of motor Motor serial no. 4 - HANDLING Electro-pumps should be handled and unpacked carefully. We recommend that the unit is handled as shown in the sketch below. IEC 34-1 (87) 3 - CHARACTERISTICS The pump mounting flanges comply with the standard NF E44-301 (DIN 5440). Each electro-pump is fitted with two identification plates, one defining the hydraulics, the other defining the motor. 3.1 - Hydraulic characteristics The hydraulic characteristics are guaranteed to conform to international standard ISO 2548 class C for massproduced pumps. TYP N PV.4.2.24 C94 0890 H max 140 m. MOTEURS LEROY-SOMER Type of electro-pump Electro-pump serial no. Maximum total manometric lift in meters 5 - STORAGE In good storage conditions, our are not at risk of deterioration. They should be stored in dry, enclosed areas away from inclement weather conditions, dust, vibration and shocks. If the storage area is not frostproof, ensure that the pump has been drained. Do not rest on the motor fan cover. Before commissioning or re-commissioning an electropump, follow the instructions given in this manual. 2

PV4 - PIV6 6 - INSTALLATION PV4 and PIV6 series have been designed to be mounted on tanks, vats, drain pans, etc. Electro-pumps should be installed by personnel who are qualified to undertake this type of work. The delivery pipe should be fitted in such a way that no mechanical force is exerted on the body of the pump. On PV4 pumps with thermoplastic delivery head, do not exceed a tightening torque of 20 Nm when screwing on the pipe fitting. We recommend that the electro-pump should be mounted on its support. The electro-pump can be installed in various positions from vertical (motor at the top) to horizontal (see drawing below). When the electro-pump axis is tilted from the vertical, it will be necessary to support the suction unit so that it does not bend. support 7 - ELECTRICAL CONNECTION Electrical connection must be performed by a qualified electrician taking all existing regulations into account. If the electro-pump has been stored in damp conditions, check the motor insulation resistance before commencing any electrical connection. This should be a minimum of 10 megohms in cold state at 500 volts for a period of 60 seconds. 7.1 - Power supply Make sure that the power supply indicated on the motor identification plate corresponds to the actual electricity supply. Check that the diameter of the incoming and outgoing conductors of the meter is adequate to supply the electropump with the correct power. 7.2 - Connections The motors are supplied with the following connections as standard: Three-phase 230/Y 400V up to 5.5 kw inclusive at 50 Hz 400V above 7.5 kw at 50 Hz Make absolutely certain that the type of connection corresponds to the mains supply voltage. It should be connected as shown in the diagram below, which appears on the terminal box lid. W2 U2 V2 W2 U2 V2 U1 V1 W1 U1 V1 W1 L1 L2 L3 connection L1 L2 L3 Y connection support The electro-pump should be installed in a well-ventilated, weatherproof area. 6.1 - Delivery pipe The diameter of the delivery pipe should be chosen after careful calculation of the installation pressure losses. A flow-control valve should be placed on this pipe. 6.2 - Before commissioning Make sure that the electro-pump rotates freely without sticking. To do this, remove the fan cover and rotate the fan a few times by hand. The minimum level of liquid in the pan should be 100 mm above the suction inlet filter. It is recommended that the electro-pump should have level detection control. Installed in the pan, this will prevent the pump starting when the water level is below the specified level. Single phase 230V single phase at 50 Hz 7.3 - Protection Connect to earth as required by existing regulations. In order to benefit from the guarantee, it is essential to protect the motor electrically by placing a thermal magnetic circuit-breaker between the isolator and the motor. This circuit-breaker may also be fused. Before starting up the electro-pump, the circuit-breaker should be set provisionally to the correct current (shown on the identification plate) for the corresponding mains supply voltage. Definitive setting should be performed as instructed in paragraph 8. So as not to subject the electro-pump to excessive temperature rises, do not exceed the maximum number of starts per hour indicated overleaf. 3

PV4 - PIV6 Motor power Max. number of starts per hour 0.55 kw 40 0.75 to 1.1 kw 35 1.5 to 3 kw 30 4 to 7.5 kw 20 The number of starts should be spread over the hour. 8 - STARTING THE PUMP UNIT An electro-pump must never be run dry. This is very important to ensure the mechanical seal remains watertight. For three-phase units, make sure that the direction of rotation is that indicated by the arrow on the fan cover, by running the motor for a couple of turns. If the direction of rotation is reversed, modify the connection to the motor terminal block by reversing 2 power supply wires. After starting, once the motor has reached its operating speed, make sure that the back pressure is normal and not subject to significant fluctuations. If this is not the case, stop the electro-pump and check that the level of liquid in the pan is more than 100 mm above the suction inlet filter as indicated in section 6.2. If the motor is not running fast enough, check the connection. Take care not to leave the pressure valve closed for more than 5 minutes. With the electro-pump operating normally, measure the maximum current drawn on each phase. Set the circuitbreaker definitively, for a slightly higher current than the maximum measured. This must never exceed the current indicated on the motor identification plate. Check that the voltage between phases at the motor terminals is correct. Any disruption to operation indicates abnormal electropump operation (voltage drop, loss of phase, incorrect setting, foreign body in the pump, sludge, etc.). The electro-pump should turn smoothly without vibrating. Never run the electro-pump with the pressure valve closed. If difficulties are experienced with priming when the electro-pump is started, either there is insufficient liquid in the pan or the pump has been drained and an air pocket is blocking the top of the pump. In this case, drain the pump by unscrewing the plug 90 shown in the diagram at the end of this document. Running the electro-pump on empty is absolutely prohibited. Motor. Drain holes: To drain condensates formed during cooling of the machines, there are holes in the lowest points in the motor housing or shields depending on the operating position. From time to time, the plastic plugs covering these holes should be removed and then replaced. 9 - STOPPING THE PUMP UNIT Switch off the electrical supply to the motor. In the event of a prolonged stop and/or where there is a risk of freezing, drain the pan and the delivery pipe or take appropriate precautions against freezing. 10 - SERVICING PV4 and PIV6 series require very little servicing. The bearings are permanently greased. Only the mechanical seal may need to be changed if noticeably worn or leaking. Electro-pumps installed as backup equipment should be run for a short time once a week to ensure that they are working properly. It is recommended that the current consumption should be checked occasionally. If this should rise without the flow increasing, this indicates an operating fault or particularly harsh operating conditions, which should be rectified. In any event, it is recommended that the electropump should be dismantled after 2 years or 10,000 hours of operation in order to examine parts subject to wear (mechanical seal, turbine, etc.) 11 - DISMANTLING - REASSEMBLY An electro-pump must be dismantled and reassembled by personnel qualified to carry out this type of work. Where one or more components of the electro-pump are being replaced (spare parts) it is essential that only parts supplied by LEROY-SOMER are used. Failure to comply with this instruction invalidates the guarantee and relieves the manufacturer of responsibility for any malfunction. Any person working on an electro-pump is responsible for the consequences. Before commencing work on the electro-pump: Disconnect the electricity supply to the motor. Close the pressure valve. Check that the pump body is not under pressure. 11.1 - Removing the motor The motor can be easily disconnected without removing the pump. To do this, remove: the protective grille 69 the 4 coupling sleeve locking screws 2.88 the 4 screws 83 and their washers 3.83 11.2 - Removing the hydraulic unit After removing the delivery pipe and the fixing for mounting the pump on the pan, remove the pump from the pan, drain it and position it vertically with the delivery head at the bottom. 4

PV4 - PIV6 11.2.1 - PV4 pump See diagram on page 8 Remove: the tube 39 after having: unscrewed the 2 tube clamping nuts delivery head 21 2.39 on the, for pumps with a thermoplastic body stopped the rotation of the delivery head 21 (use a strap spanner to do this), for pumps with a metal body Warning: This has a left hand thread. the hydraulic unit (impellers, diffusers, ferrules, cover plates, bearing, shaft, mechanical seal) the impeller tightening screw 84 by locking the shaft so as not to damage it at the other end the first cover plate 16-2 the first impeller 28 the first diffuser 29 the first ferrule 67 the bearing 11 the sleeve 07 Remove the other stages in the same way. 11.2.2 - PIV6 pump See diagram on page 9 Position the pump vertically, with the delivery head at the bottom, on a compression mounting, as shown below. Tighten the 4 tie rods, then remove: the 4 screws 2.48 the 4 locknuts 48 (tightening a screw or M6 screw rod in the locknut will enable them to be removed more easily) Unscrew and remove the compression mounting, then remove: the suction unit (tube) 39 the hydraulic unit (cell body, impellers, diffusers, shaft, mechanical seal) the impeller tightening screw 84 by locking the shaft so as not to damage it at the other end. the first cell body 13 the first impeller 28 the second cell body 13 with its diffuser 29 the second impeller 28 the bearing assembly 11 and 62 Remove the other stages in the same way. 11.3 - Changing the mechanical seal After dismantling the hydraulic unit as indicated in paragraph 2, remove: the ring 71 (after unscrewing the locking screw 2.71 on PV4 pumps) the spacer ring 72 located in the delivery head 21 Refitting a new seal: The housing for the spacer ring must be clean. Clean it and fit a new spacer ring by lubricating the rubber ring and its housing with a 10% solution of Teepol in clean water. Push the spacer ring into its housing using a plastic cylindrical mandrel. Make sure that the friction surface is clean and dry, as well as the part of the shaft on which the revolving joint 71 slides. Fit a revolving joint 71 which has been previously lubricated with the same solution as the spacer ring, using a torque tube to locate it. For PV4 pumps, slide it on until it rests on the shoulder of the shaft and lock the screws 2.71. Take care not to damage the friction surfaces of the mechanical seal during these operations. 11.4 - Reassembling the hydraulic unit Before reassembly ensure that the parts are clean and not worn. Reassemble the unit by carrying out the dismantling procedure in reverse. Use silicon grease to lubricate the thread (PV4 pumps with metal delivery head) or spigot (PIV6 pumps) of the delivery head 21 as well as the O ring seal 81, before refitting the tube. Note: After dismantling, we recommend fitting a new mechanical seal. 11.5 - Motor-hydraulic unit connection When connecting the motor to the hydraulic unit, correct compression of the mechanical seal should be obtained and the movable hydraulic assembly should be set in the centre of its axial play. Proceed as follows: 5

PV4 - PIV6 11.5.1 - PV4 hydraulic unit Mount the motor on the hydraulic unit. Replace and tighten the 4 screws 83 with their washers 3.83. Fit the pin 95 into one of the two halves of the coupling sleeve 88. Mount the coupling sleeve 88 taking care to locate the pin 95 in the groove in the shaft 24 of the hydraulic unit. Bring into contact, without tightening, the 4 coupling sleeve screws 2.88. Slide a 2.5 mm wide shim under the coupling sleeve, between the sleeve and the delivery head 21. Lock the 4 sleeve screws 2.88. Remove the shim. Fit the protective grille 69. 12 - SPARE PARTS To order spare parts, please specify: the type of electro-pump the electro-pump serial number the description of the part with its part number, as shown on the diagram and on the parts list in this document 11.5.2 - PIV6 hydraulic unit Mount the motor on the hydraulic unit. Replace and tighten the 4 screws 83. Mount the coupling sleeve 88 on the motor and hydraulic unit shaft ends. Bring into contact, without tightening, the 4 coupling sleeve screws 2.88. Lift the movable assembly and slide 20 mm wide shim under the coupling sleeve, between the sleeve and the delivery head 21. (See diagram below). Tighten the 4 sleeve screws 2.88 firmly. Remove the shim. Fit the protective grille 69. 6

PV4 - PIV6 Fault Cause Remedy The motor will not start. Circuit-breaker faulty or incorrectly set. Check the circuit-breaker. The supply voltage is correct but the voltage at the motor terminals is too low. Redo the electro-pump power supply line, increasing the diameter of the wires. The motor is not properly connected. Comply with the wiring diagram (connection to the motor). The pump will not start. The inlet filter is not sufficiently immersed. Check the immersion depth. Direction of rotation reversed Reverse 2 cables on the motor terminal Inadequate performance. The circuit-breaker trips. (3-phase motor). Delivery pipe closed by valve or other and an air pocket has formed in the upper part of the pump. Direction of rotation reversed (3-phase motor). Total manometric lift is higher than specified. block. Open the drain plug on the delivery head by unscrewing it several turns. Reverse 2 cables on the motor terminal block. Use an electro-pump with better performance or reduce the pressure losses. The pump or inlet filter are partially Clean them and remedy the problem. obstructed. Air entering on intake. Check the immersion depth of the inlet filter valve. Permanent overload due to inadequate Fit a control valve on the pump delivery TML, resulting in too high a flow. pipe to slow down the flow. Permanent overload due to excessive Please consult LEROY-SOMER. viscosity or density of the liquid being pumped. Excessive voltage drop. Increase the voltage or increase the diameter of the conductors. Operation with 2 phases (3-phase Inspect the supply cables and motor). connection terminals. Leaking mechanical seal. Faulty mechanical seal. Check and replace all the components of the mechanical seal (never run on empty). Electro-pump vibrating. In accordance with the various points Check. above. Abnormal restriction on the flanges. Check the connection of the pump on its support and the connection of the delivery pipe. They should not cause any mechanical stress. This should be eliminated by flexible collars, etc. Faulty motor bearings. Check and change the bearings (same size and type). 7

PV4 Pump with thermoplastic delivery head Pump with metal delivery head Part No. Description Part No. Description 7 Sleeve 68 Inlet filter 7.1 Spacer 69 Protective grille 7.2 Spacer 71 Revolving joint 7.8 Bearing spacer 2.71 Revolving joint screw 11 Bearing 72 Spacer ring 16.1 Cover plate 81 O ring seal 16.2 Suction plate 83 Screw 21 Delivery head 3.83 Washer 24 Shaft 84 Turbine screw 28 Turbine 3.84 Brake washer 29 Diffuser 88 Coupling sleeve 39 Tube 2.88 Coupling sleeve screw 2.39 Tube clamping nut 90 Draining plug 3.39 Tube clamping washer 95 Pin 62 Bearing bush 101 Motor 67 Ferrule 8

PIV6 83 69 88 2.24 3.24 72 71 24 101 21 2.88 3.88 48 2.48 81 07 62 2.84 84 2.68 13 29 28 11 39 68 Part No. Description Part No. Description 7 Shaft spacer 68 Inlet filter 11 Bearing cell 2.68 Inlet filter fixing screws 13 Cell 69 Protective grille 21 Delivery head 71 Revolving joint 24 Pump shaft 72 Fixed plug 2.24 Shaft end screw 81 O ring seal 3.24 Shaft end washer 83 Motor fixing screw 28 Turbine 84 Turbine locking screw 29 Diffuser 2.84 Turbine locking washer 39 Suction unit 88 Coupling sleeve 48 Bolt 2.88 Coupling sleeve screw 2.48 Locknut fixing screw 3.88 Coupling sleeve washer 62 Bearing assembly 101 Motor 9

Notes

MOTEURS LEROY-SOMER 16015 ANGOULÊME CEDEX - FRANCE RCS ANGOULÊME N B 671 820 223 S.A. au capital de 131 910 700 F http://www.leroy-somer.com