Condenser Bushings. OIL-TO-AIR - Oil-Impregnated Paper ANSI STANDARDS IEEE C AND IEEE C AN ALSTOM COMPANY

Similar documents
PNO Condenser Bushings from 52 kv to 420 kv Oil-to-air - Oil-Impregnated Paper

PABS. AIR-TO-SF 6 - Gas-insulated bushing IEC STANDARDS ANSI STANDARDS AN ALSTOM COMPANY

OIP Transformer Outdoor Bushings Type COT(C) 125 COT (C) kV to 550kV up to 5000A IEC

OIP Transformer Outdoor Bushings Type COT(C) 125 COT (C) kV to 550kV up to 5000A IEC

B kv Gas-insulated Substations

Resin Impregnated Paper Bushing, Oil to Air, Type GSB Technical guide

Transformer bushings, type GOH. Technical guide

OTCF. Grid Solutions. Capacitor Voltage Transformers 72.5 kv to 800 kv. Quality Product Design. Seismic Withstand Capability.

1ZSE en, Rev. 9. Transformer bushings, type GOB Technical guide

1ZSE en, Rev. 7. Transformer bushings, type GOB Technical guide

Product presentation CPT tech Jason Evershed, ABB Transformer Components, May 21st New RIS transformer bushings The paper-free solution

Bushings for High Voltage AC Applications

1ZSE en, Rev. 3. Wall bushings, type GSA-AA Technical guide

OIL TO AIR BUSHINGS SERIES PNO. VOLTAGE FROM 52 kv TO 245 kv

Resin Impregnated Paper Bushing, Oil to SF 6. , Type GSBK

1ZSE EN, REV. 7. Oil SF 6. bushings type GOEK Technical guide

Transformer bushings, type GOA 250. Installation and maintenance guide

1ZSE EN, REV. 4. Wall bushings type GSA-AA Technical guide

dfdf 34.5 kv and 69 kv, Type O Plus C II Condenser Bushings Technical Guide

Micafil transformer oil-sf 6 bushings GARIP / RTKG kv. Power and productivity for a better world TM ABB

1ZSC AAA en, Rev. 6. Resin impregnated paper bushing, oil to SF 6., type GSBK Technical guide

Transformer High Current Bushings Type CFPT & CFCT 36kV up to 40kA IEC

OTAA Oil Impregnated Paper (OIP) Bushing for IEEE/ANSI Market

Installation Manual Bushings, IEEE/ANSI Standard

Transformer bushings, type GSA-OA Technical guide

Transformer Bushings Type COT COT kv to 245 kv up to 3150 A IEC 137

1ZSE en, Rev. 9. Transformer bushings, type GSA-OA Technical guide

High Voltage Bushing Wells for Pad Mounted Distribution Transformers Technical Guide

1ZSC AAA EN, REV. 7. Transformer bushings type GSBK Technical guide

35-kV Thru-Bushings F Series (bolt-in) for Air-Insulated to Air-Insulated Service 200 Amp, 600 Amp, 900 Amp and 1250 Amp

kv А

General information on handling and maintenance of SDC TM Solid Dielectric Capacitor Bushings

25-kV Apparatus Bushings B Series (bolt-in) for Elbow to Air-Insulated Service 200 Amp, 600 Amp, 900 Amp and 1250 Amp

35-kV 200-kV BIL Apparatus Bushings B Series (bolt-in) for Elbow to Air-Insulated Service 200 Amp, 600 Amp, 900 Amp and 1250 Amp

OIL-TO-OIL BUSHINGS SERIES PCTO SINGLE FLANGE TYPE VOLTAGE FROM 72,5 kv TO 420 kv

35-kV Apparatus Bushings B Series (bolt-in) for Elbow to Air-Insulated Service 200 Amp, 600 Amp, 900 Amp and 1250 Amp

NXPLUS C Single busbar. Maintenance-free for lifetime

Bushing Insulators according to DIN and UNEL Standards

Transformer Bushing Type EKTO

ABB PTTR SPAIN. Zaragoza. The product: Cast coil transformers

www. ElectricalPartManuals. com Substation Transformers Primary or Secondary Open

Type HS PEXLIM-P Surge Arresters Maximum System Voltage 123 kv to 800 kv

INSTRUCTION MANUAL CRS Combined insulation bushing

25-kV Apparatus Bushings A Series (clamp-in) for Elbow to Air-Insulated Service 200 Amp and 600 Amp

2. INDUCTIVE VOLTAGE TRANSFORMERS Dry and oil-paper insulation

BUSHINGS: GENERAL INFORMATION

25 kv Apparatus Bushings

EMPAC Metal enclosed capacitor bank for wind applications

MICAFIL RIP Transformer Bushings AirRIP / RTKF kv

Eaton s Cooper Power Systems

LV Bushing Oil to Air Dry Insulation PTAB-SLV832

Surge Arresters. UltraSIL Housed VariSTAR Station Class Surge Arresters GENERAL CONSTRUCTION

Load Break Switch Type LBOR-II, Oil Immersed PTAT-LIR975 IZUA Technical Guide Nut Mount Weld Mount

BOWTHORPE EMP MEH SURGE ARRESTERS (IEC) ENERGY /// MEH SURGE ARRESTERS IEC

Low voltage bushings for pad-mounted distribution transformers Technical information guide

Review Section: 3. Definitions..the surrounding air in contact with the apparatus onto which the bushing is mounted, not inside bus duct or enclosure.

15 kv and 25 kv Thru-Bushings

شركة كهرباء محافظة القدس المساهمة المحدودة

ACCESSORIES FOR LPOF, HPPT AND XLPE HIGH VOLTAGE CABLE SYSTEMS PRODUCT CATALOGUE

DM Condenser bushings, kV DURESCA

Fluid characteristics impact performance capabilities in transformer application

GENERAL. CONSTRUCTION External

CAST RESIN TRANSFORMERS

VariSTAR Type AZE station-class surge arresters for systems through 345 kv IEEE certified

Certified for best-in-class performance, reliability, and safety. Trihal sets a new standard for dry-type cast resin transformers

Transformer Bushings Type. STARIP / STARIP -Si. Mounting Operating and Maintenance Instructions

power cable accessories

Guide Specification. Three-Phase Solid Dielectric Trident-SR with SafeVu Integral Visible Break

Distribution transformers Efficiency over life-cycle

Product presentation CPT tech Jason Evershed, ABB Transformer Components, May 21st Dry-type transformers Innovative Technology

CAST RESIN DISTRIBUTION TRANSFORMERS 2016 EDITION

GROUP D. Switch & Protective device.

A of 14. Edition : Date : Page : Document No. Amendments :

Technical Specification For Outdoor Substation Harmonic Filter Banks

PORCELAIN BUSHINGS ED Series

BOWTHORPE EMP MCA/MDA SURGE ARRESTERS (IEC) ENERGY /// MCA/MDA SURGE ARRESTERS IEC

Inductive voltage transformers

CABLE SYSTEMS. Accessories and Systems for Medium and High-Voltage Cables up to 300 kv.

CP Automatic capacitor bank

CLICK-FIT. High Voltage Accessories for Extruded Cables

B kv T&D GAS INSULATED SWITCHGEAR

en, Rev. 10. Transformer bushings, type GOH Installation and maintenance guide

Excitation system is of Static Silicon Excitation System, including excitation transformer, thyristors, and AVR.

TE S RAYCHEM RSTI-CC-58 SCREENED, SEPARABLE COUPLING SYSTEM

3M Cold Shrink 3-Conductor Inline Splice Kits QS-III 5786A- MT, 5787A-MT and 5788A-MT 25/28 kv for use with Armored and Non- Armored 3/C Cable

Surge arresters. UltraSIl Polymer-Housed VariSTar Type UI Intermediate-Class Surge arresters. General. COnSTrUCTIOn

TGK Prefabricated Substation Technical Data

SERIES TAP-CHANGER

34-SDMS-01 SPECIFICATIONS FOR

QTII (X) Series Silicone Rubber Cold Shrink Termination Kits

Bus bar Bushings up to 1.1kV and from 1.6kA to 4kA for Liquid Filled Transformers:

Design specifications

INESING GROUP. Power System Solution

SUBSTATION VACUUM CIRCUIT BREAKER (38KV)

AIR CORE REACTORS. Phoenix Electric Corporation

Field Experience & Reliability Tests for the New EasyDry Condenser Bushing LUKAS MUGGLI

Trip Circuit and Trip coil supervision Relay

SUBSTATION VACUUM CIRCUIT BREAKER (15.5KV)

SUBSTATION VACUUM CIRCUIT BREAKER (25.8 / 27KV)

Transcription:

PAO Condenser Bushings - kv BUSHINGS OI-TO-AIR - Oil-Impregnated Paper ANSI STANDARDS IEEE C.9.0-000 AND IEEE C.9.0-99 AN ASTOM COMPANY PAO bushings are capacitance-graded bushings with an oil-impregnated paper core. They meet ANSI/IEEE C.9.0-000 and C.9.0-99, standard performance characteristics and dimensions for outdoor apparatus bushings. They are designed for use in power transformers and can be installed up to a maximum inclination (up to and including kv) or 0 ( to kv) off vertical. Design, components and manufacturing technology promote an average lifetime in excess of 0 years under normal operation conditions. The bushing is designated as follows: PAO..0.00 PAO ANSI type Condenser Bushings, Oil-impregnated paper (OIP) Insulation class in kv 0 BI in kv 00 Rated current in A I---D Catalogue number I-- Drawing number D (BC) Draw ead (Bottom Connection) installed Customer Benefits Bushings with longer lifetime and higher reliability Possibility to use bushings under extreme weather condition (lower pour-point value) No oxidation phenomena typical with mineral oil No performance reduction with age Manufacturing of capacitance-graded bushings The main electrical component is the condenser body, manufactured using a continuous sheet of pure kraft paper, wound around a central conductor tube. During the winding process a series of aluminum foils are coaxially inserted between the paper layers, to achieve the best possible distribution of the radial and longitudinal electrical gradients between the central tube and the flange, which is grounded. The winding is made by computer-controlled machines, with subsequent machining to achieve the final shape. After winding, each bushing is individually assembled and placed into an oven and processed under vacuum for the appropriate period of time. Each bushing is then impregnated with oil, which has been degassed and processed so that it has a maximum water content of ppm. Each bushing is placed under pressure to insure thorough impregnation and to test that it is properly sealed. After impregnation, the bushing head is filled with a nitrogen cushion. This process is automatic and computer-controlled. GRID

Main Features PAO: ANSI/IEEE Standards condenser bushings Range from to kv Oil-impregnated paper Air side: porcelain or composite insulator Oil side: epoxy resin insulator ( to kv) or porcelain insulator (00 to kv) Partial discharge: max. pc at. Un Synthetic impregnating oil DDB (completely miscible with transformer oil) Provided with power factor tap ( to 9 kv) or voltage tap ( to kv) Draw lead for 00-00 A, to kv Draw split rod for bottom connection for 00 A, to 9 kv Bottom connection for 00 A application, kv and above Head made of special UV filter prismatic glass with oil level indicator ( to 0 kv) or fitted with metal oil reservoir and level gauge ( to kv) Flange made of cast aluminum alloy Standard installation angle, max. of off vertical (up to and included kv) or max. 0 off vertical ( to kv) other installation angles available on request Transformer-Breaker Interchangeable (TBI) Fig. : Bushings to kv Fig. : Bushings to 0 kv. HV Terminal. Metal oil reservoir. Oil level indicator. Porcelain. OIP Condenser. Winding tube. Voltage tap. Flange 9. CT space 0. Epoxy resin or Porcelain envelope 9 0 9 0. HV Terminal. Filling plug. UHV filter glass. Porcelain. OIP Condenser. Winding tube. Voltage tap. Flange 9. CT space 0. Epoxy resin or Porcelain envelope

Air side The air side insulator is made of porcelain, light grey MUNSE B.0/0. (ASA 0). It can be provided with a resin fiberglass envelope covered by silicone sheds upon request. The typical creepage distance is suitable for very highly polluted atmospheres. The shed configuration is an alternating type (short-long shed). This is the most effective solution, proven by salt spray tests.the shed profile complies with IEC -9 recommendations. A one-piece porcelain or multiple-piece porcelain, in order to meet standard or special requirements, is used for bushings. Multiple pieces are glued using epoxy resin, without use gaskets. The final porcelain is considered as a single piece (it passes tests IEC, clause ). Oil side The oil side envelope is made of a molded epoxy resin for bushings up to kv and porcelain for higher voltage ratings. This resin is a two-part compound consisting of a resin base and a hardener; the filler material is quartz sand. The epoxy resin envelope permits shapes, thickness and dimensional tolerances not possible with porcelain. As an added advantage, the epoxy resin easily accepts metal attachments, as required, to meet design requirements. The under flange sleeve length for the CT pocket is provided in accordance with ANSI/IEEE Standards. Top terminal The top terminal is made of silver plated copper. Bushings rated 00/00/00 A have a removable HV terminal (fig. - and -). This terminal is connected to the copper inner terminal lug by means of multiblade contacts and is secured to the bushing head by screws. Current ratings There are three connection alternatives for the conductor: Draw lead connection for 00 and 00 A (fig. - and -) Draw split rod for bottom rod connection for 00 A, to 9 kv Bottom connection using a rigid conductor for 00 A and above (fig. -) Using suitable accessories, any bushing rated 00 or 00 A (draw through lead installed) can be converted to 00 A (bottom connected) and vice versa. Fig. : 00 A draw lead terminal Fig. : 00 A draw lead terminal Fig. : 00 A inner lug Fig. : 00 A draw split rod for bottom connection Draw through lead interchangeability Current ANSI Standards address the dimensions, mounting holes and connections at and below the bushing flange. Bushings, for the same class, may vary slightly in external height creating few problems due to differences between various manufacturer s draw lead cable lengths and inner terminal lug connectors. This issue has been addressed by means of a split-lug draw lead connector (see fig. - and -) that provides universal interchangeability to most bushing. This eliminates the need to use an exact replacement bushing or to remove and replace the existing lug from the draw lead to mate with the bushing cap of the replacement bushing. Draw rod installation The draw rod connection (split-conductor) allows an easier and quicker bushing installation and removal as well. By simply connecting and pulling the split-conductor through the bushing, it is possible to install a 00 A rated bushing (commonly bottom connected) in the same manner of a draw-lead type bushing, saving time and money in commissioning and maintenance activities (need to drop down the oil in the transformer tank).

Head and oil level indication Bushings up to and including 0 kv have a cylindrical oil head reservoir, prismatic in shape, made of borosilicate glass, and containing a UV filter (fig. -). This head design allows easy oil level checks, even from a distance and at any angle of sight. Bushings at kv through kv have a metal head reservoir and are provided with a prismatic glass oil level indicator to verify proper oil levels (fig. -). The metal components of the head are made of cast aluminum alloy. Fig. : Head of bushings to 0 kv Fig. : Head of bushings to kv Gaskets Made of Viton (a fluoroelastomer which has better properties than nitrile, i.e. resistance to higher temperature and excellent resistance to oils, aggressive fuels and chemicals), O-ring type. They are compatible with both the fluid inside the bushing (DDB) and transformer mineral oil. The air side gaskets are sealed to carefully protect against polluting weather elements. Fig. : Cemented porcelain. Porcelain. Cement. Metal cemented ring. Flange. Silicone sealing Flange The flange is made of cast aluminum, equipped with the following accessories: ifting holes Power factor tap, for bushings to 9 kv (fig. -9) Voltage tap, for bushings to kv (fig. -0) Assembly The coupling between porcelain and metallic parts is made of Belleville spring washers placed into the bushing head. Bushings of to kv are always assembled using cemented porcelains. The cement used is a quick setting monocalcic-aluminized type. All cemented surfaces, potentially in contact with the external environment, are silicone sealed. Fig. : DDB Dodecylbenzene synthetic oil Saturated lateral chain Fig. 9: Power Factor Tap Fig. 0: Voltage Tap ---(CH ) 9- ---(CH ) Benzenic ring Insulating fluid We have over 0 years of field-proven experience with oil-impregnated paper bushings using DDB synthetic oil (DODECYBENZENE). This oil has superior dielectric and insulating characteristics than mineral oil: Superior and constant dielectric qualities (non-aging) High capability of gas absorption under electrical field stress and high temperature Negligible toxicity Excellent biodegradability Full miscibility with transformer mineral oil A very low pour point and higher flash point

Tests All bushings have electrical characteristics and are tested in compliance with ANSI/IEEE C.9.00-000 and C.9.00-99 standard general requirements and test procedure for outdoor power apparatus bushings. Design tests Dielectric Withstand Voltage Tests - ow-frequency Wet Withstand Voltage Test - Full-Wave ightning Impulse Withstand Voltage Test - Chopped-Wave ightning Impulse Withstand Voltage Test - Wet Switching Impulse Withstand Voltage ( kv) - ow-frequency Dry Withstand Voltage Test with PD measurement. Mechanical Tests - Draw-ead Bushing Cap Pressure Test - Cantilever Strength Test Thermal Tests Routine tests Capacitance and Power Factor Measurement ow-frequency Dry Withstand Test with PD Measurement Tap Withstand Voltage Mechanical Tests Packing - transportation Thanks to a special device to prevent the diffusion of the nitrogen cushion out of the head into the lower end of the bushing, each bushing can be packed and shipped secured in the horizontal position. This insures minimal crate dimensions and reduced transportation costs. Nameplate Each bushing is provided with a nameplate, containing complete electrical data and the serial number, in accordance with the requirements of ANSI Standards. The nameplate, made of stainless steel, is secured to the flange with rivets and includes: O.I.P CONDENSER BUSHINGS INS. CASS RATED CURRENT SERIA NUMBER. Identification number. Bushing code. Insulation class. Rated maximum line to ground voltage. Rated impulse withstand voltage. Rated continuous current for draw lead type. Rated continuous current for fixed conductor, bottom connection type IDENTIFICATION NUMBER -G kv VOTAGE A DRAW EAD TRANSFORMER OR C.B. BUSHING SERIA NUMBER MONTH/YEAR STANDARD REFERENCE ENGHT BEOW MOUNTING SURFACE WEIGHT kg C pf C pf UST P.F. AT 0 C %. Serial number 9. Month and year of final tests 0. Standard references. ength below mounting surface. Weight. Capacitance C. Capacitance C. Power factor value at 0 C kv BI kv A BOTTOM CONNECTED NON PCB CONTENT Fig. b: Nameplate Multi-contact blades 9 0 Fig. Fig. Fig. Fig. Fig. : Split draw lead terminal 00 A ( to 9 kv) Fig. : Split draw lead terminal 00 A ( to kv) Fig. : Bottom connection 00 A and above ( to kv) Fig. : Botttom connection 00 A and above ( to 9 kv)

PAO Range - kv Dimensions Catalogue Number Figure IEEE C.9.0- Nominal System Voltage BI Rated continuous current Arcing distance Creepage distance Weight Maximum altitude K (CT pocket) D Type kv kv A Inches Inches bs Feet Inches Inches Inches Inches Inches Inches Inches.0.00 I--00-D 99 0 00.. 90 9900..9.0.9.0..0.00 I--0-BC 99 0 00.. 0 9900..9.0... 9.0...00.00 I--00-D 000. 00 00.. 9 9900..9.0.9.0...00.00 I--0-BC 000. 00 00.. 9900..9.0....0...00.000 I--0-BC 000. 00 000.. 9900 9..9.0....0...00.000 I---BC 000. 000 000.. 9900.......0.9.0.00 I-99-00-D 99 0 00.0. 0 9900.9..0 0.0 0..9.0.00 I-99-0-BC 99 0 00.0. 9900...0....0.9 9.0.00 I-90-00-D 000 9 0 00 9.9 9. 9900.9 9.9.0.0..9 9.0.00 I-90-0-BC 000 9 0 00 9.9 9. 9900.9 9.9.0.....9 9.0.000 I---BC 000 9 0 000. 9.0 0 9900...0... 9.0. 9.0.000 I---BC 000 9 0 000. 9.0 9900..0.... 9.0..0.00 I---D 99 0 00..0 0 00 99.9.9.9...0.00 I---BC 99 0 00..0 0 00 99.9.9.9.....0.00 I---D 000 0 00.. 9 00.0..9.09...0.00 I---BC 000 0 00.. 9 00.0..9......0.000 I---BC 000 0 000.. 00.0..9......0.000 I---BC 000 0 000 0.00. 0 00. 9..0.....9.0.00 I--00-D 99 0 00 9.0 00.9 9 00....9 0..9.0.00 I--00-BC 99 0 00 9.0 00.9 9 00...... 0..9 9.900.00 I-9-00-D 99 9 900 00.. 00..9...0 9.0.9 9.900.00 I-9-00-BC 99 9 900 00.. 9 00..9..... 9.0.9 0.00.00 I-9-00-D 000 0 00 00 90.9. 00. 90.9. 9. 0..9 0.00.00 I-9-00-BC 000 0 00 00 90.9. 00. 90.9.... 0..9 0.00.000 I-9-0-BC 000 0 00 000 90.9. 00.0 0..... 0..9 0.00.000 I-9-0-BC 000 0 00 000. 0. 90 00 0. 0. 9.9... 0....00 I-9-00-D 9 000 00 0. 99. 9900....0...00 I-9-00-BC 9 000 00 0. 99. 9900.........000 I-9-0-BC 9 000 000 0. 99. 9900.0.0.......000 I-9-0-BC 9 000 000 0. 99. 9900.. 9.9.... 00..00 I--0-D 9 000 00 00. 0. 00. 0. 9. 9.. 00..00 I---BC 9 000 00 00. 0. 00. 0. 9..... 00..000 I---BC 9 000 00 000. 0. 00. 0. 9..... 00..000 I---BC 9 000 00 000. 0. 00. 0. 9......00.00 I--0-D 9 000 00 00 0.. 0 00... 0...00.00 I---BC 9 000 00 00 0.. 0 00........00.000 I---BC 9 000 00 000 0.. 0 00........ 0. 0. DIAMETER HOE 000A -.0 000A -. MINIMUM FAT DIMENSION. 000A -.0 000A -.9 MINIMUM FAT DIMENSION. Fig. : Bottom terminal type 0.0 THK 0. DIAMETER HOE. 0.0 THK Fig. : Bottom terminal type 0.0..0 SPHERICA RADIUS HOES 0. - TAP 0. DEEP FU THREAD.0 DIA B.C.. DIA. DIA D - OUN - A 0.0 HOES 0.0 - TAP 0. DEEP FU THREAD. DIA. DIA. DIA Fig. 9: Bottom terminal type Fig. 0: Bottom terminal type Fig. : Bottom terminal type D.0 SPHERICA RADIUS.0 HOES 0.0 - TAP 0. DEEP FU THREAD. DIA B.C. D

Dimensions Catalogue Number D D D D d D s n F Type Inches Inches Inches Inches Inches Inches Inches N. Inches Inches Inches Inches Inches.0.00 I--00-D...0..... 0. 0..-. fig.-......... d.l..0.00 I--0-BC...0....... 0. 0..-. fig.-.-.... b.c...00.00 I--00-D...0..... 0. 0..-. fig.-......... d.l...00.00 I--0-BC...0....... 0. 0..-. fig.-.-.... b.c...00.000 I--0-BC...0....... 0. 0..-.......... (fig.) b.c...00.000 I---BC 9...0....... 0. 0..0-......... (fig.9) b.c..0.00 I-99-00-D...0..... 0. 0..-. fig.-......... d.l..0.00 I-99-0-BC...0....... 0. 0..-. fig.-.-.... b.c. 9.0.00 I-90-00-D 9...0..... 0. 0..-. fig.-......... d.l. 9.0.00 I-90-0-BC 9...0....... 0. 0..-. fig.-.-.... b.c. 9.0.000 I---BC 9.. 9.0.9...... 0. 0..-.......... (fig.) b.c. 9.0.000 I---BC 0..00 9.0.9...... 0. 0..0-......... (fig.9) b.c..0.00 I---D.. 9.0.9.... 0...- fig.-......... d.l..0.00 I---BC.. 9.0.9.... 0...- fig.-...... (fig.0) b.c..0.00 I---D.. 9.0..... 0...- fig.-......... d.l..0.00 I---BC.. 9.0..... 0...- fig.-...... (fig.0) b.c..0.000 I---BC.. 9.0..... 0...-.......... (fig.) b.c..0.000 I---BC.. 0...... 0...0-......... (fig.) b.c..0.00 I--00-D.. 0..... 0...- fig.-......... d.l..0.00 I--00-BC.. 0...... 0...- fig.-...... (fig.0) b.c. 9.900.00 I-9-00-D.00. 0.......- fig.-......... d.l. 9.900.00 I-9-00-BC.00. 0........- fig.-...... (fig.) b.c. 0.00.00 I-9-00-D.00. 0.......- fig.-......... d.l. 0.00.00 I-9-00-BC.00. 0........- fig.-...... (fig.) b.c. 0.00.000 I-9-0-BC.00. 0........-.......... (fig.) b.c. 0.00.000 I-9-0-BC.00..9 9..... 0...0-......... (fig.) b.c...00 I-9-00-D.00..9 9.... 0...- fig.-......... d.l...00 I-9-00-BC.00..9 9..... 0...- fig.-...... (fig.) b.c...000 I-9-0-BC.00..9 9..... 0...-.......... (fig.) b.c...000 I-9-0-BC.00..9 9..... 0...0-......... (fig.) b.c. 00..00 I--0-D.00. 9........- fig.-......... d.l. 00..00 I---BC.00. 9........- fig.-...... (fig.) b.c. 00..000 I---BC.00. 9........-.......... (fig.) b.c. 00..000 I---BC.00. 9........0-......... (fig.) b.c..00.00 I--0-D.00.9.........- fig.-......... d.l..00.00 I---BC.00.9..... 9...- fig.-...... (fig.) b.c..00.000 I---BC.00.9..... 9...-.......... (fig.) b.c. Fig. : Power Factor Tap ( to 9 kv). Closing and grounding cap. Measurement electrode. Insulation tap. Gasket. Tap flange. Bushing flange. ast layer D Top terminal thread size 9 Top terminal min. thread 0 Terminal lug: figure d.r. Bottom terminal thread size Bottom terminal min. thread Bottom terminal type (fig.) Fig. : Voltage Tap ( to kv) Installation d.i = draw lead b.c. = bottom connected. Closing and grounding cap. Measurement electrode. Insulation tap. Gasket. Filling plug. Bushing flange. Connection to internal layer. Gasket 9. Gasket 0. Tap external body Fig. : Bushings head to 0 kv. HV Terminal. Multicontact blades. Copper connector. Pin. Filling plug. Belleville washers. Winding tube Fig. : Bushings head to kv. HV Terminal. Multicontact blades. Copper connector. Pin. Filling plug. Belleville washers. Winding tube

AN ASTOM COMPANY Alstom Grid Worldwide Contact Centre www.grid.alstom.com/contactcentre Tel.: + (0) 0 00 www.grid.alstom.com D D S. D USABE THD F-n D D D d K.-UN Following the acquisition of PASSONI & VIA, Alstom Grid now offers a large portfolio of condenser bushings for AC or DC operation. If you require any further information, please address your queries to rpv@alstom.com S D D To contact the manufacturer Viale Suzzani, 9 0 MIANO (Italy) Tel.: +9 0 Fax: +9 0 09 0 Email: rpv@alstom.com D Fig. : PAO bushings to 9 kv Fig. : PAO bushings to 0 kv Fig. : PAO bushings to kv D D D d F-n K GRID D D S D D D D D F-n K Grid-ITR--PAO-90-V-0-0-EN - Alstom, the Alstom logo and any alternative version thereof are trademarks and service marks of Alstom. The other names mentioned, registered or not, are the property of their respective companies. The technical and other data contained in this document are provided for information only. Neither Alstom, its officers nor employees accept responsibility for or should be taken as making any representation or warranty (whether express or implied) as to the accuracy or completeness of such data or the achievements of any projected performance criteria where these are indicated. No liability is accepted for any reliance placed upon the information contained in this brochure. Alstom reserves the right to revise or change these data at any time without further notice. Printed on paper made with pure ECF (Elemental Chlorine Free) ecological cellulose produced from trees grown in production forests under responsible management, and selected recycled three-layer fibres.