j Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Similar documents
Intertek Level 4 RTL (ASTA Recognized Laboratory Scheme)

Resin Impregnated Paper Bushing, Oil to SF 6. , Type GSBK

1ZSE EN, REV. 7. Oil SF 6. bushings type GOEK Technical guide

Zinc Oxide Surge Arrester PEXLIM Q

High Voltage Surge Arresters Buyer s Guide Section PEXLIM R

Independent Testing Laboratory for High Voltage Equipment

Transformer bushings, type GOH. Technical guide

1ZSC AAA EN, REV. 7. Transformer bushings type GSBK Technical guide

1ZSC AAA en, Rev. 6. Resin impregnated paper bushing, oil to SF 6., type GSBK Technical guide

High Voltage Technology & Testing

HMI, APRIL, Test Laboratories in Ratingen

SELECTION GUIDE. Nominal Input Voltage. Output Voltage. Input Current. Input reflected ripple current

NXE2 Series Isolated 2W Single Output SM DC-DC Converters

SELECTION GUIDE. Nominal Input Voltage. Output Voltage. Input Current. Input reflected ripple current

INSTRUCTION MANUAL CRS Combined insulation bushing

TECHNICAL SPECIFICATION FOR 11 KV CAPACITOR BANK

Resin Impregnated Paper Bushing, Oil to Air, Type GSB Technical guide

VEIKI-VNL Electric Large Laboratories Ltd. H-1158-Budapest, Vasgolyó utca 2-4. HUNGARY

High Voltage and Extra High Voltage Cables

Annex to the Accreditation Certificate D-PL according to DIN EN ISO/IEC 17025:2005

Zinc Oxide Surge Arrester EXLIM R

1ZSE en, Rev. 7. Transformer bushings, type GOB Technical guide

MV Air Insulated Switchgear TAP17. Technical Data TGOOD

AIR CORE REACTORS. Phoenix Electric Corporation

CERTIFICATE OF ACCREDITATION

Auxiliary Relay (7PJ11) and Trip Relay (7PJ12)

CERTIFICATE OF ACCREDITATION

Zinc-Oxide Surge Arrester TEXLIM Q-C

Guide Specification. Three-Phase Solid Dielectric Trident-SR with SafeVu Integral Visible Break

VariSTAR Type AZE station-class surge arresters for systems through 345 kv IEEE certified

Technical Specification of GECOL. Packaged Transformers

Pankaj Khali, ABB India Limited Representing :ABB Switzerland limited, September 2016 Generator Circuit-Breakers. Technical Seminar: PLN

Documents and Addresses

SELECTION GUIDE. Nominal Input Voltage. Output Voltage. Input Current. Input reflected ripple current

Medium voltage products. KEVCD A combined current and voltage sensor Instructions for installation, use and maintenance

OIP Transformer Outdoor Bushings Type COT(C) 125 COT (C) kV to 550kV up to 5000A IEC

tests Partial discharge level from day 1 10 pc Insulation 24 kv : impulse tested at 125 kv Insulation 36 kv : impulse tested at 170 kv, 200 kv indeed.

Transforming Energy.. For Advanced Technology

NXPLUS C Single busbar. Maintenance-free for lifetime

OFFSHORE WIND FEASIBILITY STUDY APPENDICES Appendix C.2 Subsea Cable Data Sheets

TECHNICAL SPECIFICATION FOR 11 KV AUTOMATIC CAPACITOR SWITCH

Guideline No.: E-07(201610) E-07 TRANSFORMERS. Issued date: October 28,2016. China Classification Society

SERIES TAP-CHANGER

Solid Dielectric Load Break Switch SPECIFICATION. 25kV, 630A, 4 WAYS, 4 WAYS SWITCHED PADMOUNTED VACUUM LOAD INTERRUPTER

Prüffeld der Schaltwerke

Guideline No.: E-07(201712) E-07 TRANSFORMERS. Issued date: December 26, China Classification Society

Item 1: Contents of the complete training & CV of the lecturer

Pantograph disconnector type GW54, up to 550 kv Maximum reliability and minimal maintenance

Transformer High Current Bushings Type CFPT & CFCT 36kV up to 40kA IEC

Surge Arresters. UltraSIL Housed VariSTAR Station Class Surge Arresters GENERAL CONSTRUCTION

1ZSE en, Rev. 3. Wall bushings, type GSA-AA Technical guide

S.No. Tender Queries BRPL Reply 1 For 11KV(E) 3Cx300sqmm A2XWY High Ampacity cable conductor details specification not

Combined Current and Voltage Instrument Transformer CVS-P-24-O Technical Specifications

Energy Division. PCA Single Column Polymeric Surge Arrester

Surface mounting, flush mounting, and DIN track mounting

013 : 2009 CEB SPECIFICATION MOULDED CASE CIRCUIT BREAKERS

1ZSE EN, REV. 4. Wall bushings type GSA-AA Technical guide

Energy Transmission & Distribution Services - Italy. SVEPPI laboratory...our services for your success. Answers for energy.

3 Cold Shrink Silicone Rubber Skirted Termination Kit QT-III 7672-S-8 Series

MEDIUM VOLTAGE PRODUCT. TJC 4 Indoor voltage transformers

Maximum temp. rise in oil by 40 thermometer above design ambient (deg C) specified time Short circuit rating (Sec) for As per IS 2026

Guideline No.: E-07(201501) E-07 TRANSFORMERS. Issued date: October 20,2015. China Classification Society

INTRODUCTION. The plug-in connection on the cables and lightning arrestors, allows for easy installation and replacement.

1ZSE en, Rev. 9. Transformer bushings, type GOB Technical guide

CAST RESIN DISTRIBUTION TRANSFORMERS 2016 EDITION

Disconnectors and earthing switches up to 25 kv AC

S840, S845, S846 Series Single-break changeover, NC or NO contacts, positive opening operation and wiping action Catalogue D40.en

MEDIUM VOLTAGE AIR INSULATED ARC-RESISTANT LOAD BREAK AND DISCONNECT SWITCHES

NXE1 Series Isolated 1W Single Output SM DC-DC Converters

045 : 2000 CEB STANDARD

Compact Integrated Distribution Substation (CIDS)

AS/NZS AS/NZS

On-Load Tap changer Type V

3EP1 Surge Arrester. Metal-oxide surge arrester without series gaps for high-voltage systems up to U m. = 170 kv

020: 2013 CEB SPECIFICATION MINIATURE CIRCUIT BREAKER (MCB)

ABB PTTR SPAIN. Zaragoza. The product: Cast coil transformers

Solid State Relays, 3-phase

B kv T&D GAS INSULATED SWITCHGEAR

TECHNICAL SPECIFICATION FOR 11 KV DROP OUT (D.O.) FUSE with Polymeric Insulators:

SIGMA SERIES DE METER

The University of New South Wales. School of Electrical Engineering and Telecommunications. Industrial and Commercial Power Systems Topic 2

MGJ1 Series 5.7kVDC Isolated 1W SM Gate Drive DC/DC Converters

SWITCHBOARDS (LV and MV)

High Voltage Surge Arresters Buyer s Guide Section PEXLIM P-Y

Molded Vacuum Reclosers The recloser you want, all in one package. Single- and Three-Phase Molded Vacuum Reclosers, 15 38kV

Fluid characteristics impact performance capabilities in transformer application

OIP Transformer Outdoor Bushings Type COT(C) 125 COT (C) kV to 550kV up to 5000A IEC

Issue Title Remarks. Instrument transformers See IEC 61869

Bus bar Bushings up to 1.1kV and from 1.6kA to 4kA for Liquid Filled Transformers:

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Product presentation CPT tech Jason Evershed, ABB Transformer Components, May 21st New RIS transformer bushings The paper-free solution

On-load tap-changer OILTAP V

CERTIFIED TEST REPORT

INTERNATIONAL STANDARD

Unified requirements for systems with voltages above 1 kv up to 15 kv

Miniaturecircuitbreaker(MCB),6A,1Np,C-Char,AC. Application Switchgear for industrial and advanced commercial applications.

I Surge Arresters. UltraSIL Polymer-Housed VariSTAR Type U3 Surge Arrester for Systems through 275 kv IEC 10 ka; Line Discharge Class 3 GENERAL

The comprehensive portfolio of the testing laboratories at Schaltwerk Berlin siemens.com/energy/psw

Anti-Icing System on Nordex wind turbines - lightning protection and operating experience. Dr. J. Birkemeyer. Winterwind

TECHNICAL REQUIREMENTS FOR ELECTRICAL EQUIPMENT

Transcription:

j Schedule of Accreditation Laboratory locations: Ridley Street lyth Northumberland NE24 3AG United Kingdom ORE Catapult Development Services Limited a subsidiary of Contact: Geoff Richardson Tel: +44 (0)1670 359 555 Fax: +44 (0)1670 359 666 E-Mail: Geoff.Richardson@ore.catapult.org.uk Website: www.ore.catapult.org.uk s covered by the organisation and their relevant activities details Activity code Address ORE Catapult 50m lade Test Facility Euroseas Centre Albert Street lyth Northumberland NE24 1LZ Local contact Dr G Richardson WIND TURINE LADES - Physical A1 Address ORE Catapult 100m lade Test Facility Albert Street lyth Northumberland NE24 1LZ United Kingdom Local contact Dr G Richardson WIND TURINE LADES - Physical A2 Address Charles Parsons Technology Centre High Quay lyth NE24 2AZ Local contact Dr G Richardson POWER CALES Assessment Manager: NP Page 1 of 6

DETAIL OF ACCREDITATION WIND TURINE LADES Physical testing A1 (ORE Catapult 50m lade Test Facility) Full-scale testing of rotor blades: IEC TS 61400-23:2001 excluding cl. 13.10, Creep cl. 13.11, Other non-destructive testing cl. 13.12, lade sectioning Static testing Fatigue testing Natural frequency testing Centre of Gravity and mass PR10011, iss 4 PR10012, iss 4 PR10015, iss 2 PR10081, iss 3 Test Facility limiting dimensions: Hub Centre: 4.2 m above floor Hub Centre: 15 m from winch wall Floor to roof: 10 m Max individual force: 400 kn Max strain: 10,000 strain Max Laser distance: 20 m String pots: 0-15 m Surface Temperature: 0-50 C nominal Four Wire Resistance : 0-1000 Ω Assessment Manager: NP Page 2 of 6

WIND TURINE LADES (ORE Catapult 100m lade Test Facility) Physical testing Full-scale testing of rotor blades: Static testing Fatigue testing Natural frequency testing Centre of Gravity and mass Test Facility limiting dimensions: Hub Centre 1: 3.75 m above floor Hub Centre1: 8.1 to 35.7 m from winches Hub Centre 2: 10 m above floor Hub Centre2: 8.1 to 35.7 m from winches Floor to roof: 25 m IEC TS 61400-23:2001 excluding cl. 13.10, Creep cl. 13.11, Other non-destructive testing cl. 13.12, lade sectioning A2 Max individual force: 600 kn Max strain: 10,000 µ strain Max Laser distance: 24 m String pots: 5.00 constant force irrespective of extension Surface Temperature: 0-50 C nominal Four Wire Resistance : 0-1000 Ω Power Cables 1 kv to 30kV (IEC 60502-2) 30 kv to 150 kv (IEC 60840) Partial Discharge (PD) EC 60885-3, 2.4.1 IEC 60502-2 (2014), 18.2.5 IEC 60840 (2011), 12.4.4 S 6622, 17.5 S 7835, 18.5 IEC 61442 (2005), cl 7 Assessment Manager: NP Page 3 of 6

Power Cables (cont d) Tan Delta IEC 60502-2 (2014),18.2.6 IEC 60840 (2011), 12.4.5 S 6622 (2007), 20.4 and 20.5 S 7835 (2007), 21.4 and 21.5 S 7870-2 (2011), 3.11.1, and 3.11.3.1 Heat cycle IEC 60502-2 (2014),18.2.7 IEC 60840 (2011), 13.3.2.4 S 6622 (2007), 20.6 S 7835 (2007), 21.6 S 7870-2 (2011), 3.8 Heat cycle voltage test IEC 60840 (2011), 12.4.6 IEC 60840 (2011), 13.2.4 IEC 61442 (2005), cl 9 Impulse testing IEC 60230 (2002) IEC 60502-2 (2014),18.2.8 IEC 60840 (2011), 12.4.7 IEC 60840 (2011), 13.2.5 S 6622 (2007), 20.7 S 7835 (2007), 21.7 S 7870-2 (2011), 3.2.4 IEC 61442 (2005), cl 6 HVAC IEC 60502-2 (2014),18.2.8 and 18.2.9 IEC 60840 (2011), 12.4.7 S 6622 (2007), 20.8 S 7835 (2007), 21.8 and 19.18.1 S 7870-2 (2011), 3.2.5 IEC 61442 (2005), cl 4 Resistivity of semiconducting screens IEC 60502-2 (2014) 18.2.10 Assessment Manager: NP Page 4 of 6

Insulated ushings for alternating voltages above 1 kv Power transformers. insulation levels, dielectric tests and external clearances in air Dry or wet PF withstand (up to 600 kv) Dry lightning impulse test (up to 400 kv) EMC test (up to 400 kv) Temperature rise test Capacitance and tan delta s Partial discharge s (up to 600 kv) Test of tap insulation Full wave lightning impulse test (up to 400 kv) Lightning impulse tests on a neutral terminal S EN (IEC) 60137 : 2008 Clauses 8.1 8.3 8.6 8.7 9.1 9.4 9.5 S EN (IEC) 60076-3:2013, Clauses: 13.2 13.4 Low-voltage switchgear and controlgear assemblies. Power switchgear and controlgear assemblies Dielectric properties Power-frequency withstand 0 to 5000 V 100 ma Impulse withstand voltage 0 to 32 kv Lightning Impulse Power Frequency with stand for Insulated enclosures Verification of temperature rise by testing with current. 8000 A, 10 C to180 C Mechanical Operation S EN (IEC) 61439-2:2011 S EN (IEC) 61439-1:2011 10.9 10.9.2 10.9.3 10.9.4 10.10.2 10.13 Low-voltage switchgear and controlgear assemblies: usbar trunking systems (busways) Verification of temperature rise by testing S EN (IEC) 61439-6:2012 10.10.2 Assessment Manager: NP Page 5 of 6

High-voltage switchgear and controlgear IEC62271-1: Edition 1.1 2011 IEC 62271-100 Edition 2.1 2012 IEC 62271-102 Edition 1.2 2013 IEC 62271-103 Edition 1.0 2011 IEC 62271-200 Edition 2.0 2011 IEC 62271-201 Edition 1.0 2006 Dielectric tests Wet and dry tests Power frequency voltage tests AC voltage 0 kv to 600 kv Lightning impulse voltage tests 0 kv to 400 kv Clause 6.2 Clause 6.2.6.1 (IEC 60060-1 Edition 3 2010-09) Clause 6.2.6.2 (IEC 60060-1 Edition 3 2010-09 lightning impulse) Clause 6.4 Measurements of the resistance of Circuits 0 mw to 200 mw, 0 A to 200 A Temperature-rise tests 8000 A, 10 C to 180 C Clause 6.5 Cables Conditioning - PF withstand - wetting for 500 hr Ageing - 50 Hz for 17500 hr and - 500 Hz for 3000 hr Ageing assessment - Power frequency voltage step test S 7870-2: 2011 Clause 5.4.15 Harmionised long duration test - 5.4.15.3.2 Conditioning - 5.4.15.3.3 Ageing procedure (50 Hz ageing) - 5.4.15.3.4 Ageing assessment (step breakdown test) Clause 5.4.8 Test of resistance to water (500 Hz ageing) END Assessment Manager: NP Page 6 of 6