P/3P Series MAX 2 I/min - 27 bar 9 High pressure filters
P/3P Series Features & Benefits Features Compact aluminium housing Two head sizes and two bowl lengths Large ports and wide flow paths Microglass III replacement elements, electrical and electronic indicators available Advantages Light weight but still robust design Optimised sizing Low differential pressure across housing and element Multi-layered design produced high capacity and efficiency Wire support reduces pleat bunching, keeps performance consistent Check element condition at a glance Right style for the application Benefits Reliable and continuous operation both in mobile and industrial applications Efficient filtration Right filter for each application Higher flow rates possible Less lost energy Great performance value Reliable performance throughout element life Reduces downtime, maximises element life Optimise element life, prevent bypassing Matches your system electrical connections Typical Applications Saw mills Aircraft ground support equipment Asphalt pavers Hydraulic fan drives Power steering circuits Domestic refuse vehicles Cement trucks Servo control protection Logging equipment The Parker Filtration P/3P Series High Pressure Filters. These application examples have one thing in common...the need for clean hydraulic fluid. Modern high pressure hydraulic systems are demanding. Better controls and long component life are expected. To deliver the high standards of performance, hydraulic components are built with tighter tolerances which increases their sensitivity to contamination. That s where Parker pressure filters come into play. They filter out ingressed contamination before it jams a valve or scores a cylinder. They block pump generated debris before it gets to servo or proportional valves. Parker pressure filters are a key ingredient in meeting today s system demands. Put your hydraulic systems in the care of Parker Filtration. We are committed to designing and building the best filters available to industry. 9 Parker Hannifin Hydraulic Filter Division Europe FDHB2UK. Section 2
Specification Pressure ratings: Maximum allowable operating pressure 27 bar. Filter housing pressure pulse fatigue tested: 38 bar. Connections: Inlet and outlet connections are threaded. Connection style Model P 3P BSPF(G) 3 / 4 ISO 49 M27 M33 Filter housing: Head material extruded aluminium (anodised -T). Bowl material impacted aluminium (anodised -T). Seal material: or Fluoroelastomer. Operating temperature range: -2 C to + C. Bypass valve: Opening pressure 3. bar. Filter element: Degree of filtration: Determined by multipass-test according to ISO 889. Flow fatigue characteristics: Filter media is supported so that the optimal fatigue life is achieved (ISO 3724). Microglass III: Supported with epoxy coated metal wire mesh, end cap material reinforced composite and metal inner core. Collapse rating 24 bar (ISO 294). High collapse elements: High collapse elements available. For details please contact Parker Filtration. Indicator options: Indicating differential pressure: 2. ±.3 bar. - visual M3. - electrical T. - electronic F(PNP). - electronic F2(NPN). For indicator details see catalogue section. Weights (kg): Model Length P. 2. 3P 2.9 3.9 Fluid compatibility: Suitable for use with mineral and vegetable oils, and some synthetic oils. For other fluids, please consult Parker Filtration. Installation Details P Series 23..9. 4. Torque 74-9 Nm (-7 Ft lbs) 4..8 2.8.8..99 79.4.3 3.2..22.2 79.4 3.3 Dia..8.3.2. 49..93 2.4. 2.4 9.8 P-2 28.7.2.3.8.9 P-2 2. 2.4 Torque 4-48 Nm.8 2. Minimum cartridge removal clearance.3. P- 73.-2.3.83-.9 P- Optional / SAE- drain port torque 2-27 Nm (-2 ft lbs) Bottom View 4.3 2.3 23.9.94 97 High pressure filters
P/3P Series Installation Details (cont.) 3P Series Torque 74-9 Nm (-7 Ft lbs) 9. 3..7 2.3 3..2 mm (inches).4 2.2 24.4.9 Side view 2. 229. 8.27 9.4 3P- 3P- 7.2 2.9 Torque 88-9 Nm (-7 Ft lbs) 338.8 3.34 3P-2 39.3 2.7 3P-2. 4. Minimum cartridge removal clearance 4.8 4.3 dia Bottom view Optional str thd drain port / SAE- ( / 2-2 UNF-2B) Torque 2-27 Nm (-2 Ft lbs) 92. 3.3 dia 9.9 2.7 34.9.37.3 dia thru 2 total.4 2.3 2. 28.8.2 Hex. 4. Port to port 9..7 Optional mounting bracket (923) 3.8.2 7 3 4 Index Description P 3P Head 2 Bypass assembly 3 Element See chart in product configurator 4 Bowl O-ring buna N9238 N92 Bowl O-ring fluoroelastomer V9238 V92 Bowl Drain plug c/w buna seal Drain plug c/w Fluoroelastomer seal 7 Nameplate Blank indicator kit Indicators M3 auto reset indicator FMUM3KVAU4M T indicator FMUTKVAU4M F Electronic indicator PNP with 4 LED FMUFKVAU4M F2 Electronic indicator NPN with 4 LED FMUF2KVAU4M 2 3 4 98 Parker Hannifin Hydraulic Filter Division Europe FDHB2UK. Section 2
Pressure Drop Curves The recommended level of the initial pressure drop is max..2 bar. If the medium used has a viscosity different from 3 cst, pressure drop over the filter can be estimated as follows: p = ( p3 x viscosity of medium used) / 3 cst. P Empty Housing 2 2 2 3P Empty Housing 2 3 4 2. 2. 2 Δ p (bar).. P- P-2 Δ p (bar).. 3P- 3P-2. 2 4 8. 2 P- Elements 3P- Elements 2 2 2 3 2 39 3 79 2... 2Q Q Q 2Q 2... 2Q Q Q 2Q 2. 2 4 8. 2 2 3 P-2 Elements 3P-2 Elements 2 2 2 3 2 39 3 79 2. 2Q 2. 2Q 2.. Q Q 2Q.. Q 2Q Q. 2 4 8. 2 2 3 99 High pressure filters
P/3P Series Ordering Information Standard products table Part number PQBM3KG2 PQBTKG2 P2QBM3KG2 P2QBTKG2 3PQBM3KG 3PQBTKG 3P2QBM3KG 3P2QBTKG Supersedes P--Q-M2--B2B2- P--Q-TW3--B2B2- P-2-Q-M2--B2B2- P-2-Q-TW3--B2B2-3P--Q-M2--C2C2-3P--Q-TW3--C2C2-3P-2-Q-M2--C2C2-3P-2-Q-TW3--C2C2- Flow (l/min) 4 4 7 7 2 2 7 7 Model number P P P P 3P 3P 3P 3P Element length Length Length Length Length Media rating (µ) Note: Filter assemblies ordered from the product configurator below are on extended lead times. Where possible, please make your selection from the table above. Note : Part numbers featured with bold highlighted codes will ensure a standard product selection. Note 2: Alternate displayed part number selection will require you to contact Parker Filtration for availability. Seals Indicator Bypass settings 3. bar 3. bar 3. bar 3. bar 3. bar 3. bar 3. bar 3. bar Ports G" G" G" G" Replacement elements 9392Q 9392Q 939Q 939Q 939Q 939Q 9394Q 9394Q Product configurator Box Box 2 P Box 3 Q Box 4 B Box M3 Box K Box 7 G2 Box 8 Box Model High pressure filter, T-port High pressure filter, T-port Box 2 Length Length Filter type 2 Box 3 P 3P Element media Microglass III element Degree of filtration Glass fibre 2Q Highlights Key (Denotes part number availability) 23 23 23 23 Item is standard Item is standard green option Item is semi standard Item is non standard Note: Standard items are in stock, semi standard items are available within four weeks Media code Q Q 2Q Box 4 Seal material Fluoroelastomer Seal type B V Box Plugged with steel plug indicator indicator No indicator port Electronic 4 LED, PNP, N.O. Electronic 4 LED, NPN, N.O. Electronic 4 LED, PNP, N.C. Electronic 4 LED, NPN, N.C. Indicator P M3 T N F F2 F3 F4 Box Bypass and indicator settings Bypass valve 3. bar Indicator 2. bar K When filter includes a bypass valve but not an indicator, code denotes bypass setting. Box 7 Filter connection Connections P: Thread G 3 / 4 Thread M27, ISO 49 3P: Thread G Thread M33, ISO 49 G2 M27 G M33 Box 8 Options Standard Drain port on bowl Options 4 Media 2Q Q Q 2Q Replacement elements with nitrile seals P- 939Q 939Q 9392Q 9393Q P-2 9394Q 939Q 939Q 9397Q 3P- 9398Q 9399Q 939Q 939Q 3P-2 9392Q 9393Q 9394Q 939Q Filter model P- P-2 3P- 3P-2 Nominal flow (I/min) at viscosity 3 cst 2Q 2 4 7 2 Q 3 9 Q 4 7 2 7 2Q 7 9 7 2 ßx(c)=2.% Degree of filtration Average filtration beta ratio ß (ISO 889) / particle size µm [c] ßx(c)= ßx(c)=7 ßx(c)= ßx(c)=2 ßx(c)= % efficiency, based on the above beta ratio (ßx) 9.% 98.7% 4. 8. 7 99.% 9 8 99.% 2 99.9% 4. 7 2 22 Disposable Microglass III 2Q Q Q 2Q Parker Hannifin Hydraulic Filter Division Europe FDHB2UK. Section 2