Saddleback Cove / P.O. Box 088 Travelers Rest, SC 9690 EC-30-SM Travelers Rest, SC: 800-476-403 Simi Valley, CA: 800-43-050 Fax: 864-834-358 www.tsbrass.com " [5mm] Faucet [0mm] Deck Mounting Hole Detail 3" 76mm 0" 54mm /" [38mm] Side Mount Control This Space for Architect/Engineer Approval Job Name Date Model Specified Quantity Customer/Wholesaler Contractor Architect/Engineer B-740 Side Mount Control Regulates Water Temperature and ON/OFF Setting. Note: To Ensure Proper Operation Sensor Faucet, Side Mount Control Should Remain in the OPEN Position at All Times. Spout w/. GPM Vandal Resistant Aerator 0" Chrome Plated Forged Brass Deck Plate Mounting Surface /" NPSM x / NPSM 8" [457mm] Long Flexible /" NPSM, 3" [330mm] Flexible Stainless Steel Hose for Tempered Water. Connect to Control Module Using /" Close Nipple () 3/8" Compression, 7" [43mm] Flexible () Check Valve Asm for Crossflow Prevention H T 0mm Removable Strainer C [60mm] Sensor Cable Chrome Plated Brass Electronic Faucet: Deck Mount Cast Spout w/ VR Aerator, Side Mount Temperature Control, AC/DC Control Module w/ Internal Flow Control Switches, 7" Long Hot & Cold Supply Hoses w/ Check Valve Assemblies 3 5/8" x 4 3/6" x " Deep [9mm x 06mm x 5mm] Water Resistant Control Module Box (Blue) w/ Internal Flow Control Setting Switches, AC or DC Operated w/ (4) AA Batteries. Hardwire Capable Using Terminals on Back 4 3/8" mm " [5mm] Maximum Thickness 4 7/8" 4mm 00-40 VAC Adapter w/ 4 [3658mm] Long Double Power Cord. (Remove Rubber Plugs on Module and Cable to Connect) 5 3/8" 37mm ASME A.8. / CSA B5. NSF 37 (Low Lead Content) /8" [3mm] Anti-rotation Pin. Remove Pin if Desired. (See Mounting Hole Detail) Box May Contain Extra Hoses That Are Not Needed and May be Discarded After Final Installation Drawn: GEF Checked: DMH Approved: JHB Date: 05/07/4 Scale: :7 Sheet:
Saddleback Cove / P.O. Box 088 Travelers Rest, SC 9690 EC-30-SM Travelers Rest, SC: 800-476-403 Simi Valley, CA: 800-43-050 Fax: 864-834-358 www.tsbrass.com ITEM NO. SALES NO. DESCRIPTION 06355-45 Aerator w/ Key, Vandal Resistant,. GPM, 3/6-7 Male 0795-45 Angled Sensor w/ Cable 3 0697-45 Inlet Hose, Faucet, /" NPSM-F x / NPSM-F 4 06647-45 ChekPoint Module (Blue) 5 5EF-000 Double Gang, Plug-in AC Transformer 6 00534-5 Close Nipple, /" NPT 7 B-740 Side Mount Control w/ Hoses & Ceramic Crtg 8 03080-45 Ceramic Cartridge, B-730 9 0649-5 CV Asm, 3/8" Comp-F x 3/8" Comp-M 0 0545-45 Vandal Resistant Key 05084-40 0" Deck Plate w/ Side Mount Hole EC-FILTER Replacement Filter 8 7 3 4 A Maximum (8) ChekPoint Faucets can be Hardwire Connected and Powered by EC-HARDWIRE ChekPoint Hardwire AC Transformer. (Sold Separately) Label for Flow Control Switch Settings is Located on Inside Back Cover. 0 6 5 Flow Control Switches are Located Inside Module Housing in Black Box Next to Battery Compartment. *Switches are Set to DEFAULT Position: - Auto Time Out = 5 Seconds - Shut Off Delay = Second - Auto Flush = OFF 9 Remove (4) Screws and Back Cover to Access Switches. *Available Water Flow Control Selections: - Auto Time Out: 5 sec, 30 sec, 45 sec, 60 sec, 3 min, 0 min - Shut Off Delay: sec, 0 sec, 5 sec, 30 sec - Auto Flush (30 Seconds After Every Inactive Hours): ON or OFF Chrome Plated Brass Electronic Faucet: Deck Mount Cast Spout w/ VR Aerator, Side Mount Temperature Control, AC/DC Control Module w/ Internal Flow Control Switches, 7" Long Hot & Cold Supply Hoses w/ Check Valve Assemblies ASME A.8. / CSA B5. NSF 37 (Low Lead Content) Drawn: GEF Checked: DMH Approved: JHB Date: 05/07/4 Scale: NTS Sheet:
Saddleback Cove / P.O. Box 088 Travelers Rest, SC 9690 EC-30-SMT4 Travelers Rest, SC: 800-476-403 Simi Valley, CA: 800-43-050 Fax: 864-834-358 www.tsbrass.com 6 /" 65mm This Space for Architect/Engineer Approval Job Name Date Model Specified Quantity 5/8" 66mm Customer/Wholesaler Contractor Architect/Engineer Chrome Plated Die Cast Deck Plate 0mm 3 5/8" x 4 3/6" x " Deep [9mm x 06mm x 5mm] Water Resistant Control Module Box (Blue) w/ Internal Flow Control Setting Switches, AC or DC Operated w/ (4) AA Batteries. Hardwire Capable Using Terminals on Back EC-SMT Above Deck Side Mount Adjustable Thermostatic Mixing Valve 7/6" 6mm /" NPSM x / NPSM 8" [457mm] Long Flexible Removable Strainer [60mm] Sensor Cable Mounting Surface 4 3/8" mm Solid Cast Brass Spout w/ Polish Chrome Plated Finish and 06355-45,. GPM [8.3L/min] Vandal Resistant Aerator 4 7/8" 4mm 5 3/8" 37mm 7/8" mm Maximum Thickness 00-40 VAC Adapter w/ 4 [3658mm] Long Double Power Cord. (Remove Rubber Plugs on Module and Cable to Connect) /" NPSM x /" NPSM 6" [406mm] Long Flexible Rough-In Requirement: () " [5mm] Mounting Holes () 3/8" Compression x /" NPSM 8" [457mm] Flexible Stainless Steel Supply Hose Shank Nut Wrench ASME A.8. / CSA B5. Spout w/ Centers Deck Plate, Above Deck Side Mount NSF 37 (Low Lead Content) AC/DC Control Module with Internal Flow Control Setting Switches, 8" Long Hot & Cold Supply Stop Flexible Connector Hoses ASSE 070 (TMV) Drawn: GEF Checked: DMH Approved: JHB Date: 05/07/4 Scale: :6 Sheet:
Saddleback Cove / P.O. Box 088 Travelers Rest, SC 9690 EC-30-SMT4 Travelers Rest, SC: 800-476-403 Simi Valley, CA: 800-43-050 Fax: 864-834-358 www.tsbrass.com 3 4 5 6 7 ITEM SALES NO. NO. 06355-45 8 9 DESCRIPTION Aerator w/ Key, Vandal Resistant,. GPM, 3/6-7 Male 0795-45 Angled Sensor w/ Cable 3 0850-45 ChekPoint C-C SMT Deck Plate 4 0854-45 M4 x 0mm, SS, Torx VR FH Screw 5 0849-45 Handle 6 0848-45 Temperature Limit Stop 7 EC-SMT Above Deck Thermostatic Mixing Valve w/ Handle 8 0697-45 Inlet Hose, Faucet, /" NPSM-F x / NPSM-F 9 06647-45 ChekPoint Module (Blue) 0 EC-FILTER Replacement Filter 00534-5 Close Nipple, /" NPT 5EF-000 Double Gang, Plug-in AC Transformer 3 0667-45 Supply Hose, /" NPSM Female x /" NPSM Female 4 5EF-0005 Supply Hose, 9/6-4 Female x /" NPSM A Maximum (8) ChekPoint Faucets can be Hardwire Connected and Powered by EC-HARDWIRE ChekPoint Hardwire AC Transformer. (Sold Separately) 0 4 Label for Flow Control Switch Settings is Located on Inside Back Cover. 08543-45 0545-45 *Available Water Flow Control Selections: - Auto Time Out: 5 sec, 30 sec, 45 sec, 60 sec, 3 min, 0 min - Shut Off Delay: sec, 0 sec, 5 sec, 30 sec - Auto Flush (30 Seconds After Every Inactive Hours): ON or OFF Spout w/ Centers Deck Plate, Above Deck Side Mount AC/DC Control Module with Internal Flow Control Setting Switches, 8" Long Hot & Cold Supply Stop Flexible Connector Hoses Drawn: GEF Checked: DMH Approved: JHB Date: 3 05/07/4 Flow Control Switches are Located Inside Module Housing in Black Box Next to Battery Compartment. *Switches are Set to DEFAULT Position: - Auto Time Out = 5 Seconds - Shut Off Delay = Second - Auto Flush = OFF Remove (4) Screws and Back Cover to Access Switches. ASME A.8. / CSA B5. NSF 37 (Low Lead Content) ASSE 070 (TMV) Scale: NTS Sheet:
Saddleback Cove / P.O. Box 088 Travelers Rest, SC 9690 EC-30-SMT4V05 Travelers Rest, SC: 800-476-403 Simi Valley, CA: 800-43-050 Fax: 864-834-358 www.tsbrass.com 6 /" 65mm This Space for Architect/Engineer Approval Job Name Date Model Specified Quantity 5/8" 66mm Customer/Wholesaler Contractor Architect/Engineer Chrome Plated Die Cast Deck Plate 0mm 3 5/8" x 4 3/6" x " Deep [9mm x 06mm x 5mm] Water Resistant Control Module Box (Blue) w/ Internal Flow Control Setting Switches, AC or DC Operated w/ (4) AA Batteries. Hardwire Capable Using Terminals on Back EC-SMT Above Deck Side Mount Adjustable Thermostatic Mixing Valve 7/6" 6mm /" NPSM x / NPSM 8" [457mm] Long Flexible Removable Strainer [60mm] Sensor Cable Mounting Surface 4 3/8" mm Solid Cast Brass Spout w/ Polish Chrome Plated Finish and B-099-08-N05, 0.5 GPM VR Spray Device 4 7/8" 4mm 5 3/8" 37mm 7/8" mm Maximum Thickness 00-40 VAC Adapter w/ 4 [3658mm] Long Double Power Cord. (Remove Rubber Plugs on Module and Cable to Connect) /" NPSM x /" NPSM 6" [406mm] Long Flexible Rough-In Requirement: () " [5mm] Mounting Holes () 3/8" Compression x /" NPSM 8" [457mm] Flexible Stainless Steel Supply Hose Shank Nut Wrench ASME A.8. / CSA B5. Spout w/ Centers Deck Plate, Above Deck Side Mount NSF 37 (Low Lead Content) 0.5 GPM VR Spray Device, AC/DC Control Module with Internal Flow Control Setting Switches, 8" Long Flexible Supply Hoses ASSE 070 (TMV) Drawn: GEF Checked: DMH Approved: JHB Date: 05/07/4 Scale: :6 Sheet:
Saddleback Cove / P.O. Box 088 Travelers Rest, SC 9690 EC-30-SMT4V05 Travelers Rest, SC: 800-476-403 Simi Valley, CA: 800-43-050 Fax: 864-834-358 www.tsbrass.com ITEM SALES NO. NO. DESCRIPTION B-099-08- N05 0.5 GPM VR Spray Device, 3/6-7 Male 0795-45 Angled Sensor w/ Cable 3 0850-45 ChekPoint C-C SMT Deck Plate 4 0854-45 M4 x 0mm, SS, Torx VR FH Screw 5 0849-45 Handle 6 0848-45 Temperature Limit Stop 7 EC-SMT Above Deck Thermostatic Mixing Valve w/ Handle 8 0697-45 Inlet Hose, Faucet, /" NPSM-F x / NPSM-F 9 06647-45 ChekPoint Module (Blue) 0 EC-FILTER Replacement Filter 00534-5 Close Nipple, /" NPT 5EF-000 Double Gang, Plug-in AC Transformer 4 3 0667-45 Supply Hose, /" NPSM Female x /" NPSM Female 4 5EF-0005 Supply Hose, 9/6-4 Female x /" NPSM 3 5 6 7 8 9 A Maximum (8) ChekPoint Faucets can be Hardwire Connected and Powered by EC-HARDWIRE ChekPoint Hardwire AC Transformer. (Sold Separately) 0 4 08543-45 0545-45 *Available Water Flow Control Selections: - Auto Time Out: 5 sec, 30 sec, 45 sec, 60 sec, 3 min, 0 min - Shut Off Delay: sec, 0 sec, 5 sec, 30 sec - Auto Flush (30 Seconds After Every Inactive Hours): ON or OFF Spout w/ Centers Deck Plate, Above Deck Side Mount 0.5 GPM VR Spray Device, AC/DC Control Module with Internal Flow Control Setting Switches, 8" Long Flexible Supply Hoses Drawn: GEF Checked: DMH Approved: JHB Date: 3 05/07/4 Label for Flow Control Switch Settings is Located on Inside Back Cover. Flow Control Switches are Located Inside Module Housing in Black Box Next to Battery Compartment. *Switches are Set to DEFAULT Position: - Auto Time Out = 5 Seconds - Shut Off Delay = Second - Auto Flush = OFF Remove (4) Screws and Back Cover to Access Switches. ASME A.8. / CSA B5. NSF 37 (Low Lead Content) ASSE 070 (TMV) Scale: NTS Sheet:
Saddleback Cove / P.O. Box 088 Travelers Rest, SC 9690 EC-30-SMT8 Travelers Rest, SC: 800-476-403 Simi Valley, CA: 800-43-050 Fax: 864-834-358 www.tsbrass.com This Space for Architect/Engineer Approval 0 / 60mm Job Name Date Model Specified Quantity 5/8" 66mm Customer/Wholesaler Contractor Architect/Engineer Chrome Plated Die Cast Deck Plate 0mm 3 5/8" x 4 3/6" x " Deep [9mm x 06mm x 5mm] Water Resistant Control Module Box (Blue) w/ Internal Flow Control Setting Switches, AC or DC Operated w/ (4) AA Batteries. Hardwire Capable Using Terminals on Back EC-SMT Above Deck Side Mount Adjustable Thermostatic Mixing Valve 7/6" 6mm /" NPSM x / NPSM 8" [457mm] Long Flexible Removable Strainer [60mm] Sensor Cable 4 3/8" mm Mounting Surface Solid Cast Brass Spout w/ Polish Chrome Plated Finish and 06355-45,. GPM [8.3L/min] Vandal Resistant Aerator 4 7/8" 4mm 5 3/8" 37mm 7/8" mm Maximum Thickness 00-40 VAC Adapter w/ 4 [3658mm] Long Double Power Cord. (Remove Rubber Plugs on Module and Cable to Connect) /" NPSM x /" NPSM 6" [406mm] Long Flexible Rough-In Requirement: () " [5mm] Mounting Holes () 3/8" Compression x /" NPSM 8" [457mm] Flexible Stainless Steel Supply Hose Shank Nut Wrench ASME A.8. / CSA B5. Spout w/ 8" Centers Deck Plate, Above Deck Side Mount NSF 37 (Low Lead Content) AC/DC Control Module with Internal Flow Control Setting Switches, 8" Long Hot & Cold Supply Stop Flexible Connector Hoses ASSE 070 (TMV) Drawn: GEF Checked: DMH Approved: JHB Date: 05/07/4 Scale: :6 Sheet:
Saddleback Cove / P.O. Box 088 Travelers Rest, SC 9690 EC-30-SMT8 Travelers Rest, SC: 800-476-403 Simi Valley, CA: 800-43-050 Fax: 864-834-358 www.tsbrass.com 3 4 5 6 7 ITEM SALES NO. NO. 06355-45 DESCRIPTION Aerator w/ Key, Vandal Resistant,. GPM, 3/6-7 male 0795-45 Angled Sensor w/ Cable 3 085-45 ChekPoint 8" C-C SMT Deck Plate 4 0854-45 M4 x 0mm, SS, Torx VR FH Screw 5 0849-45 Handle 6 0848-45 Temperature Limit Stop 7 EC-SMT Above Deck Thermostatic Mixing Valve w/ Handle 8 0697-45 Inlet Hose, Faucet, /" NPSM-F x / NPSM-F 9 06647-45 ChekPoint Module (Blue) 0 EC-FILTER Replacement Filter 00534-5 Close Nipple, /" NPT 5EF-000 Double Gang, Plug-in AC Transformer 3 0667-45 Supply Hose, /" NPSM Female x /" NPSM Female 4 5EF-0005 Supply Hose, 9/6-4 Female x /" NPSM 8 9 A Maximum (8) ChekPoint Faucets can be Hardwire Connected and Powered by EC-HARDWIRE ChekPoint Hardwire AC Transformer. (Sold Separately) 0 4 Label for Flow Control Switch Settings is Located on Inside Back Cover. 08543-45 0545-45 *Available Water Flow Control Selections: - Auto Time Out: 5 sec, 30 sec, 45 sec, 60 sec, 3 min, 0 min - Shut Off Delay: sec, 0 sec, 5 sec, 30 sec - Auto Flush (30 Seconds After Every Inactive Hours): ON or OFF Spout w/ 8" Centers Deck Plate, Above Deck Side Mount AC/DC Control Module with Internal Flow Control Setting Switches, 8" Long Hot & Cold Supply Stop Flexible Connector Hoses Drawn: GEF Checked: DMH Approved: JHB Date: 3 05/07/4 Flow Control Switches are Located Inside Module Housing in Black Box Next to Battery Compartment. *Switches are Set to DEFAULT Position: - Auto Time Out = 5 Seconds - Shut Off Delay = Second - Auto Flush = OFF Remove (4) Screws and Back Cover to Access Switches. ASME A.8. / CSA B5. NSF 37 (Low Lead Content) ASSE 070 (TMV) Scale: NTS Sheet:
Saddleback Cove / P.O. Box 088 Travelers Rest, SC 9690 EC-30-SMT8V05 Travelers Rest, SC: 800-476-403 Simi Valley, CA: 800-43-050 Fax: 864-834-358 www.tsbrass.com 0 / 60mm This Space for Architect/Engineer Approval Job Name Date Model Specified Quantity 5/8" 66mm Customer/Wholesaler Contractor Architect/Engineer Chrome Plated Die Cast Deck Plate 0mm 3 5/8" x 4 3/6" x " Deep [9mm x 06mm x 5mm] Water Resistant Control Module Box (Blue) w/ Internal Flow Control Setting Switches, AC or DC Operated w/ (4) AA Batteries. Hardwire Capable Using Terminals on Back EC-SMT Above Deck Side Mount Adjustable Thermostatic Mixing Valve 7/6" 6mm /" NPSM x / NPSM 8" [457mm] Long Flexible Removable Strainer [60mm] Sensor Cable 4 3/8" mm Mounting Surface Solid Cast Brass Spout w/ Polish Chrome Plated Finish and B-099-08-N05, 0.5 GPM VR Spray Device 4 7/8" 4mm 5 3/8" 37mm 7/8" mm Maximum Thickness 00-40 VAC Adapter w/ 4 [3658mm] Long Double Power Cord. (Remove Rubber Plugs on Module and Cable to Connect) /" NPSM x /" NPSM 6" [406mm] Long Flexible Rough-In Requirement: () " [5mm] Mounting Holes () 3/8" Compression x /" NPSM 8" [457mm] Flexible Stainless Steel Supply Hose Shank Nut Wrench ASME A.8. / CSA B5. Spout w/ 8" Centers Deck Plate, Above Deck Side Mount NSF 37 (Low Lead Content) 0.5 GPM VR Spray Device, AC/DC Control Module with Internal Flow Control Setting Switches, 8" Long Flexible Supply Hoses ASSE 070 (TMV) Drawn: GEF Checked: DMH Approved: JHB Date: 05/07/4 Scale: :6 Sheet:
Saddleback Cove / P.O. Box 088 Travelers Rest, SC 9690 EC-30-SMT8V05 Travelers Rest, SC: 800-476-403 Simi Valley, CA: 800-43-050 Fax: 864-834-358 www.tsbrass.com ITEM SALES NO. NO. DESCRIPTION B-099-08- N05 0.5 GPM VR Spray Device, 3/6-7 Male 0795-45 Angled Sensor w/ Cable 3 085-45 ChekPoint 8" C-C SMT Deck Plate 4 0854-45 M4 x 0mm, SS, Torx VR FH Screw 5 0849-45 Handle 6 0848-45 Temperature Limit Stop 7 EC-SMT Above Deck Thermostatic Mixing Valve w/ Handle 8 0697-45 Inlet Hose, Faucet, /" NPSM-F x / NPSM-F 9 06647-45 ChekPoint Module (Blue) 0 EC-FILTER Replacement Filter 00534-5 Close Nipple, /" NPT 5EF-000 Double Gang, Plug-in AC Transformer 4 3 0667-45 Supply Hose, /" NPSM Female x /" NPSM Female 4 5EF-0005 Supply Hose, 9/6-4 Female x /" NPSM 3 5 A Maximum (8) ChekPoint Faucets can 6 be Hardwire Connected and Powered by EC-HARDWIRE ChekPoint Hardwire AC 7 8 Transformer. (Sold Separately) 9 0 4 08543-45 0545-45 *Available Water Flow Control Selections: - Auto Time Out: 5 sec, 30 sec, 45 sec, 60 sec, 3 min, 0 min - Shut Off Delay: sec, 0 sec, 5 sec, 30 sec - Auto Flush (30 Seconds After Every Inactive Hours): ON or OFF Spout w/ 8" Centers Deck Plate, Above Deck Side Mount 0.5 GPM VR Spray Device, AC/DC Control Module with Internal Flow Control Setting Switches, 8" Long Flexible Supply Hoses Drawn: GEF Checked: DMH Approved: JHB Date: 3 Label for Flow Control Switch Settings is Located on Inside Back Cover. Flow Control Switches are Located Inside Module Housing in Black Box Next to Battery Compartment. *Switches are Set to DEFAULT Position: - Auto Time Out = 5 Seconds - Shut Off Delay = Second - Auto Flush = OFF Remove (4) Screws and Back Cover to Access Switches. 05/07/4 ASME A.8. / CSA B5. NSF 37 (Low Lead Content) ASSE 070 (TMV) Scale: NTS Sheet: