SHARKBITE INSTALLATION GUIDE

Similar documents
SHARKBITE INSTALLATION GUIDE

Installation Instructions

Equal tee push-fit on all ends


Table of Contents. SeaTechInc.com

Compression Fittings & Valves. Make the connection

SECTION 2 SAFETY, TOOLS AND EQUIPMENT, SHOP PRACTICES UNIT 7: TUBING AND PIPING

Compression Fittings & Valves. Make the connection

Ball Valves. Full Port Ball Valves - Compression w/ Drain Cap - Forged Brass. Full Port Mini Ball Valve - Forged Brass 05/06/15

Quick- Connect. Quick-Connect Plumbing Products Canadian Catalogue and Price List. Effective April 27, Watts. c a

EverTUFF CPVC CTS Fittings, Valves, Pipe & Cement

PVC & CPVC Copper Tubing. Insulated Pipe Steel Conduit. Plastic Conduit SDR-35. Dual Containment Glass Pipe

TBM Series 3-Way Ball Valve

The Carbon Steel Push-fit System

PVC WELL CASING & FITTINGS 20 FT. BELL-END /8 SDR21 REDUCING COUPLINGS STEEL WELL CASING & FITTINGS

METAL PRESSURE PIPE PIPE & TUBING PIPE & TUBING GALVANIZED PRESSURE PIPE ASTM A-53 ERW BLACK GAS PIPE ASTM A-53 ABOVE GROUND LARSEN SUPPLY CO., INC.

PRESS TOOLS PRODUCT CATALOG

Underground Gas Polyethylene (PE) Piping

GAS DISTRIBUTION PRODUCTS METER RISERS

Price List. Quick-Connect Plumbing Products. Effective October 30, Watts.com QUICK-CONNECT Catalog and Price List

ROMAC INDUSTRIES, INC. WIDE RANGE RESTRAINT. RESTRAINED END CAP page 6-7 NOW AVAILABLE FOR HDPE PIPE NO STIFFENER REQUIRED

M-8100EP. Installation Guide ENGINEERED PLASTIC MANIFOLD SERIES. Introduction. A. Assemble Manifold Components

1" QickZone Modular Brass Manifold Installation Instructions Parts List

Installation Guide. Single-Control Bath and Shower Trim A K K K 12021

SDR-26 (160 PSI) SDR-21 (200 PSI) SDR-17 (250 PSI) MINIMUM WALL (IN.) 20 LENGTH. 1.5" 1.900" N/A N/A N/A.090" ".419 lbs..415 lbs.

Engine Oil Leak at Crankshaft Rear Main Oil Seal (Replace with Revised Crankshaft Rear Main Oil

Jones Stephens Corp. PlumBest LTConnections SECTION D - FITTINGS & VALVES. Brass Compression Fittings

PVC Stargrip series 4000 Mechanical Joint Wedge Action Restraint for Plastic Pressure Pipe

Innerlynx Type UL Fire Rated 3Hour Fire Stop ADVANCE PRODUCTS & SYSTEMS, INC. ISO-9001 CERTIFIED COMPANY - FM

PVC Stargrip series 4000 Mechanical Joint Wedge Action Restraint for Plastic Pressure Pipe

INTELLIGENT WATER FLOW METERS. Installation Guide

A. This Section includes piping and related specialties for general-service compressed-air systems operating at 150 psig or less.

VITALink Taped Splice Pigtail Crimp

Chlorine Valves and Accessories

Snow Melt EN_US_2014_V2.indb 171 2/7/ :18:52 AM

Manifold Isolation Valves

INSTALLATION INSTRUCTIONS

Gauge Assembly and Maintenance

Clamps. for Plastic Tubing & Hose. Fluid Transfer Specialists

Series 900 Slitter Shaft

TEXAS UNITED PIPE INC.

INSTRUCTION MANUAL- PLANT OPERATIONS

PB900-GT SLOTBLASTER D-A PLEASE READ BEFORE USING THIS EQUIPMENT

M Installation Guide. PRECISION Manifold Series. Introduction. A. Assemble Manifold Components

HVS S 15kV Class

CATALOG. USMetrixQC is a Quick Connect Manifold system for warm and cold running water, and central heating systems. USMetrix QC

Ecoflex Pre-insulated Pipe Systems

PVC Pressure Piping Systems for Water Transmission

PERFORMANCE GPM of Water At Total Head in Feet

CONTENTS. Procrimp Water and Gas Pipe and Fitting System 4. Procrimp Brass Fittings 5. Procrimp Brass Fittings Range 6

SALEEN SPEEDLAB BOOST AND WATER TEMPERATURE GAUGE POD KIT

High-Strength Steel Reinforced HDPE Pipe. For pipe specifications, please visit:

PRODUCT GUIDE MADE IN USA

Advantages of Grooved Fittings

OWNER S MANUAL EVOLUTION 3500, 4500, 5500, & 8500 SERIES PUMPS

Tools. Tubing Tools. Rotrac Plus. Mini Tube Cutters. Tube Cutter. Ratchet Tube Cutter. π to 2-5/8 OD

Product Installation Guidelines MARCH 2008

Catalogue Easy inside

GB-250. Submittal Specifications Installation Application Specific Details

Installation Instructions

5600 Control Valve. Bypass Piping Boss Inlet & Outlet. Distributor Tube and basket. Brine Well. Brine Line. Over-Flow (Optional) $1.

Installation Guide PHILMAC 3G TM COMPRESSION FITTINGS. Turn On To Faster Installation TM

Instructions. Certifications Chrome less spray Chrome with spray 10-K82-WNCH-AD-Z Chrome less spray 10-K82-WYCH-AD-Z Chrome with spray

PEX-AL-PEX Compression Fittings. Plugs...12 Couplings Elbows Male Thread Adapters. Dielectric Unions Brass Ball Valves

SM64052 Maintenance & Repair Manual Commercial 2" Unisex Coupling - Valved Model 64052

VALSIR SUPPLY SYSTEMS MIXAL

Ford Service Saddles and Tapping Sleeves

Raychem CSJA Safety Instructions. Safety Instructions. Customer Service. Kit Contents. Installation Instructions

Installation and Maintenance Instructions

ELB ELB

FITTINGS AND FABRICATIONS DESIGNED AND ENGINEERED HIGH DENSITY POLYETHYLENE PIPE

Ecoflex potable PEX plus pre-insulated pipe system Installation guide

SECTION VIII. (Sub-section 430) Wastewater Valves and Appurtenances. 1. General thru Gate Valves thru 430-3

INSTALLATION & OPERATING INSTRUCTIONS

Pipe Penetrations Sealed ADVANCE PRODUCTS & SYSTEMS, INC. Innerlynx Type UL Fire Rated 3Hour Fire Stop.

Solvent Cements. LOOK INSIDE for the industry s most detailed cure charts. The choice of plumbing professionals.

PRESS TOOLS PRODUCT CATALOG

Installation Instructions

1-1/2 Inch Self-Priming Centrifugal Pumps Refer to pump manual for General Operating and Safety Instructions.

LOKRING Automotive Service Connectors For the Automotive AC Field

ASSEMBLY INSTRUCTION MANUAL

Edition 1

Aspen Lift Part Number Spectrum Lane ~ Missoula MT ~

Installation Instructions

Immersion Wells and Compression Fittings FOR TEMPERATURE CONTROLLERS

Installation Instructions

CONEX Works, Santry Avenue, Dublin 9, Ireland Tel: (0) Fax: (0)

House Hydrant Installation Instructions

2311FA. Pressure Tester USER INSTRUCTION MANUAL BARFIELD M/N 2311FA Revision C April 12, 2011 BARFIELD, INC. Corporate Headquarters

Steel Suction Line Accumulators

Freedom Lift. Part Number 57961

Instructions. Certifications. Two Handle Kitchen Faucet. Tools Required. Maintenance. Safety Tips. Important Points. Things You May Need.

Installation Instructions

SERIES II WALVIT + CUBE. 1.28/0.8 Gal (4.8/3 Litre)

HYMAX GRIP Wide-Range Restraint Solutions

BALL VALVES. Industry-Leading 300psi Low Lead Ball Valves

Transair. Specification Submittal

For assistance call T&M. Tubing and manifolds. installation guide

Innerlynx Type UL Fire Rated 3 Hour Fire Stop. ISO-9001 Certified Company - FM

FLUID POWER FLUID POWER EQUIPMENT TUTORIAL PIPE WORK. This work covers part of outcome 2 of the Edexcel standard module:

Transcription:

SHARKBITE INSTALLATION GUIDE

THE TOTAL PLUMBING SOLUTION CUT: Cut the pipe square removing rough edges and debris. Mark the pipe to the correct insertion depth. PUSH: Push pipe and fitting together up to the depth mark. DONE. *Using the disconnect clip, fittings can be easily changed, removed and reused. SHARKBITE FITTINGS / PIPE SIZE COMPATIBILITY / PIPE INSERTION DEPTH Nominal Size of Fitting Nominal Size of Pipe Pipe OD Size Pipe ID Size Pipe Insertion Decimal Depth Fraction 1/4" 1/4" CTS 3/8" 0.305" 0.81" 13/16" 3/8" 3/8" CTS 1/2" 0.350" 0.94" 15/16" 1/2" 1/2" CTS 5/8" 0.475" 0.95" 15/16" 5/8" 5/8" CTS 3/4" 0.652" 1.13" 1-1/8" 3/4" 3/4" CTS 7/8" 0.671" 1.13" 1-1/8" 15/16" 1" 1" CTS 1-1/8" 0.885" 1.32" 1-5/16" Pipe Insertion Depth 1-1/4" 1-1/4" CTS 1-3/8" 1.055" 2.0" 2" 1-1/2" 1-1/2" CTS 1-5/8" 1.245" 2.25" 2-1/4" 2" 2" CTS 2-1/8" 1.629" 2.50" 2-1/2" 1/4" compression 1/4" ACR 1/4" 0.190" n/a 3/8" compression 3/8" ACR 3/8" 0.311" n/a 1/2" SharkBite End ii sharkbite.com

THE SHARKBITE CONNECTION SYSTEM The SharkBite connection system is certified for potable water and hydronic applications. SharkBite uses an advanced push-to-connect design that works in two stages. When the pipe is inserted into the fitting it passes the first stage through a release collar and then through a stainless steel grab ring. The grab ring has teeth that open out and grip onto the pipe. At the second stage the pipe is pushed through an o-ring protector which aligns the pipe. A specially formulated o-ring is then compressed between the wall of the fitting and the pipe before the end of the pipe reaches the tube stop. O-RING PROTECTOR SUPPORT SLEEVE GRAB RING FIRST STAGE TUBE STOP O-RING SECOND STAGE RELEASE COLLAR DZR LEAD FREE BODY PEX STIFFENER Only when the pipe has passed through the o-ring and reaches the tube stop is a secure joint created. The SharkBite fittings can only be used with pipe/ tubing certified to the following specifications: PEX (ASTM F876, CSA B137.5) Copper (ASTM B 88) The SharkBite fittings have an integral PEX Stiffener that is effective in supporting PEX, PE-RT, and HDPE tubing to ensure the o-ring seals correctly on the outside of the pipe. The PEX Stiffener is not required for use with CPVC and copper tubing, however these two types of tubing fit over the PEX Stiffener easily and hold it against the tube stop. CPVC (ASTM D 2846, CSA B137.6) PE-RT (ASTM F 2769) HDPE (SDR-9 ASTM D2737) 1

CONNECTING A SHARKBITE JOINT The following instructions must be followed to assemble the SharkBite Connection System. PREPARATION Select the correct size fitting and pipe for the job. Check that fittings and pipe are clean, in good condition and are free from damage and foreign objects. Also check that the pipe is free from scratches, cuts, or gouges. Cut the pipe so that the ends are square. Ensure that there are no burrs or damage to the cut end. Wherever possible proper pipe cutting tools such as rotary pipe cutters (copper tubing) or pipe shears (for plastic pipe) should be used. Once the pipe end is cut square and clean, use the SharkBite Depth Deburr Gauge (sold separately) and a permanent marker to mark the insert depth on the outside of the pipe. This mark is used to ensure that the joint is assembled correctly. To assemble correctly, the pipe needs to be pushed into the fitting until it meets the tube stop. Follow these three steps to insert the pipe into the fitting. 1. Insert the pipe through the release collar to rest against the grab ring. 2. Push the pipe firmly with a slight twisting action until it reaches the tube stop. 3. To ensure that the pipe is correctly inserted, check that the depth mark is within 0.005 in (0.13 mm) of the end of the release collar 2

DISCONNECTING A JOINT Disconnection of the joint can only occur by using either the SharkBite disconnect clip or the SharkBite disconnect tongs. By applying pressure to the release collar with the clip or the disconnect tongs, the grab ring teeth are splayed. This action releases the pipe, allowing it to be removed from the fitting. 1. Place the SharkBite disconnect clip around the pipe with the non-branded face against the release collar. If using the SharkBite disconnect tongs, place the teeth around the fitting assembly. The fork end with the SharkBite brand logo should be positioned around the pipe and the other end around the neck of the fitting. 2. Push the clip against the release collar and pull the pipe with a twisting action to release the pipe. If using the SharkBite disconnect tongs, squeeze the tool with one hand and pull the pipe with a twisting action to release the pipe. 3. Check the fitting and pipe end for damage. The fitting and pipe should be free of damage, foreign objects and marks on the outside diameter. If the pipe is damaged or marked, then cut and use a new section of pipe. 3

INSTALLATION REQUIREMENTS SHARKBITE BURIAL SharkBite Universal fittings are suitable for burial in most applications; however care is required when using fittings in applications that require burial to ensure the correct installation practices are used and due care is given to any environmental factors that may have a detrimental effect on the life expectancy of the fittings and pipe. The installation of SharkBite Universal fittings in applications that will require the burial of the fitting must comply with all local plumbing code requirements. SharkBite Universal fittings and SharkBite PEX are not suitable for use in areas where the soil is or may become contaminated* including the soil used for back filling. All SharkBite Universal fittings with brass bodies must have an impervious barrier between the fitting and the surrounding soil. Self-fusing, formaldehyde and chloride-free, fully cured silicone tape with a minimum thickness of 0.020" should be used for this purpose. The soil used for back filling must be free of rocks, debris or any sharp objects that may cause damage to the fitting or pipe through impact or abrasion. * Examples of contamination include, but are not limited to, petrochemicals (reclaimed service station sites), high levels of nitrogen compounds (this could be caused by animal waste or fertilizer that may be found in some agricultural applications), low ph levels (below ph 6), high ph levels(above ph 8), run off from land fill, formaldehyde compounds, and solvents. It should be noted that such contaminants have been known to migrate through plastic piping systems and contaminate the Potable water supplied through these pipes. SHARKBITE SILICONE BURIAL WRAP Make a SharkBite Universal connection ensuring pipe is inserted to proper depth. While leaving the protective film in place, measure the amount of tape needed to completely wrap the fitting. To ensure a proper seal, overlap tape by 1"past the end of the fitting on every end and 1/4" 1/2" between/across the fitting. Wrap the fitting by pulling the tape tight and removing the protective film. Completely cover the fitting. The tape will bond to itself within minutes and will cement to itself within a few hours forming an air and water tight seal. SHARKBITE FITTINGS IN CONCRETE Do not allow joints within the slab. Use a continuous length of SharkBite PEX Pipe within the slab and be sure to check for leaks before pouring concrete. SHARKBITE DISTANCE BETWEEN FITTINGS Allow at least 1" of spacing between SharkBite Universal fittings for removal purposes. SHARKBITE GROUNDING ON COPPER PIPE When connecting a SharkBite Universal fitting to a copper piping system, install a copper jumper cable to ensure proper grounding. SharkBite Universal fittings are not an electrically continuous fitting. 4

THREADED CONNECTORS Teflon tape should be used with threaded SharkBite connectors to make a proper seal. GALVANIZED TUBING SharkBite Universal fittings should not be installed (threaded or push-to-connect) on galvanized tubing. SHARKBITE SOLDERING When soldering is required near a SharkBite Universal connection, make all solder joints first and then make the SharkBite connections. Flame can cause the pipe to reach high temperatures and should not be used close to a SharkBite Universal fitting. WORKING PRESSURE AND TEMPERATURE SharkBite Universal fittings have a maximum temperature of 200 F maximum pressure 200 psi when used on copper pipe. When used on PVC, CPVC, PEX, PE-RT or HDPE refer to the maximum pressure temperature rating of the pipe. PEX STIFFENERS SharkBite Universal fittings (3/8" to 1") come with an Integral PEX Stiffener. 1/4" (3/8" OD) fittings do not require PEX stiffeners. PEX Stiffener are required for PEX, PE-RT and HDPE pipe. 2XL PEX Stiffeners sold separately. SHARKBITE FITTING REUSE SharkBite Universal fittings are intended to be a permanent connection and are not designed for repeated connection and disconnection. If the need arises to change a fitting after initial installation this can be done given that proper care is taken when removing and reinstalling SharkBite Universal fittings. 1. SharkBite disconnect tongs or SharkBite disconnect clips must be used when removing the fittings. 2. The initial pipe and the new pipe must be clean and free from scratches and burrs. 3. Mark the correct insertion depth, insert the fitting to the mark, turn the water back on and check for leaks. 5

Reliance Worldwide Corporation 2300 Defoor Hills Rd NW, Atlanta, GA 30318 Phone: 1-877-700-4242 Fax: 1-877-700-4280 rwc.com Reliance Worldwide Corporation (Canada) Inc. 74 Alex Avenue Vaughan, Ontario, L4L 5X1 Phone: 1-888-820-0120 Sales Inquiries: canadasales@rwc.com Orders: canadaorders@rwc.com sharkbite.com 6 Manufactured and Distributed by Reliance Worldwide Corporation