Model P720 Peristaltic Pump

Similar documents
MODEL 905V OPERATING INSTRUCTIONS

Thermo Scientific Manostat. Simon. & Vera. Variable Flow Pumps. Ideal for a wide variety of life science and medical applications: Features

PUMP SYSTEM OPERATING MANUAL:

Warner Instruments 1125 Dixwell Avenue, Hamden, CT (800) / (203) (203) fax

Pneutronics. Miniature Proportional Valves. Catalog PND-MPV-001/US January 2007

2 Model 826 Dispensing Valve User Guide

Heated Perfusion Cube

GE Sensing & Inspection Technologies

MODEL 901 OPERATING INSTRUCTIONS

Model 616 Rotating Disk Electrode Instruction Manual

CABINET REEL OPERATING INSTRUCTIONS

6 Gauge Box Set with Programmable Speedometer. Made in the USA. Caution. Speedometer Parts. Tachometer Parts. Fuel Level Gauge Parts.

VSO Thermally Compensated Proportional Valve

Miniature Proportional Valve Thermally Compensated Proportional Valve. Physical Properties

KEY FEATURES. Compact components for 360 µm, 1/16, and 1/32 inch ID tubing Fast, breadboard-based design Leak-free high pressure setups

Normally Open Miniature Proportional Valve Thermally Compensated Proportional Valve

User manual ma Loop Calibrator Jofra macal

INSTRUCTION MANUAL 272-5X5 ANALOG TRANSMITTER (210 SERIES FLOW METERS) 272-5X7 ANALOG TRANSMITTER (220/240 SERIES FLOW METERS)

Warner Instruments 1125 Dixwell Avenue, Hamden, CT (800) / (203) (203) fax

Operator Instructions for Tension Links

Musical Surroundings Presents:

BULLETIN NO.ELEC IM121/10A Replaces IM121/09A

PEAKTRONICS DMC-101 ADDITIONAL FEATURES. DC Motor Controller, 5A DMC-101

Power Operated Retrofit Kit for Manual Door 230 VAC or 440/480 VAC 50/60 Hz Installation and Setup Manual

TELEDYNE HASTINGS INSTRUMENTS

Miniature Proportional Valves Precision Fluidics

Model 2053 Conductivity Meter Instruction Manual

Installation Instructions

Model 322 Automated Thermocouple Calibrator Operating Instructions. Product Description. Practical Instrument Electronics

TERMINATOR User Manual

OPERATING INSTRUCTIONS

EPS/ELA-Series User Manual EPS/ELA 250W

INSTRUCTION MANUAL 276-5XX SERIES 4-20MA TRANSMITTERS

Flow Limit Safety Shutoff Valves Model 1

700 Series FluidVision

200 Series Flow Meters

Air Spray Proportioning Valve

Peristaltic Pump Operating Instructions

Exercise 2: Series-Opposing DC Sources

DriveRight VSS Installation Guide

SALDET SALES & SERVICE, INC. CLINTON TOWNSHIP, MICHIGAN

Installation Instructions

3000 Series Operation Manual

Pipe fi ttings MUST be installed by a certifi ed welder only. Signet will not assume liability of any kind for improper fi tting installations.

MPPV-2, 4, 6, 8 Valve Instruction Manual Date:12/1/16

MultiCal. Operation Manual for MultiCal mmhga/psia Pressure Module

fax

Laboratory Room Controller

PIECAL 322 Automated Thermocouple Calibrator Operating Instructions. Product Description

SD Bendix E-10PR Retarder Control Brake Valve DESCRIPTION. OPERATION - Refer to Figure 2

Filter Holder Manifold User Guide. 3- and 6-Place Stainless Steel Manifolds 3- and 6-Place Sterility Test Manifolds 3-Place PVC Manifold

Piezoresistive Pressure Sensor

MAINTENANCE INFORMATION ====================

500 SERIES METERING FLOW SWITCHES TECHNICAL REFERENCE MANUAL. Proteus Industries Inc. Proteus 5-Year Warranty

BENCHTOP INSTRUMENT. Multi-channel DC Power Supply TP2000N/TP2000PU/TP4000N Series Operation Manual V1.0

DMC mA Positioner

Quick Reference Guide

EVP SERIES PROPORTIONAL CONTROL VALVES

K10 Intrinsically Safe Electro-Pneumatic Positioner Operating Manual

Geopump Peristaltic Pump Installation and Operation Manual

MALCOM Table-Top Digital Viscometer Model PC-1TL Series

Therm-L-Tec Building Systems LLC. Therm-L-Tech. Power Operated Retrofit Kit 230 VAC or 440/480 VAC 50/60 Hz Installation and Setup Manual

Radnoti Modular Wire Myograph System Assembly and Basic Principles

Config file is loaded in controller; parameters are shown in tuning tab of SMAC control center

S-SERIES DISPLACEMENT TRANSDUCERS

Piezoresistive Absolute Pressure Sensor

PICO Pµlse Contact Dispense Valve

Pipe fittings MUST be installed by a certified welder only. +GF+ SIGNET will not assume liability of any kind for improper fitting installations.

Analog Condensate Monitor Instruction & Maintenance Manual

Troubleshooting Bosch Proportional Valves

User s Manual. Model VC-8 Perfusion Valve Controller. Sweden U.S.A. Spain. Canada. United Kingdom. France. China. Germany

ML6420, ML7420 Non-Spring Return Electric Linear Valve Actuators

Flow System Accessories

MITYFLEX PERISTALTIC PUMPS

DEMA BLEND CENTER MODELS: 637GAP-1 and 637GAP-4 INSTALLATION INSTRUCTIONS

ETgage Model E Instructions

MPA Chassis for Multi-Probe Magnetic Transducers

BENCHTOP INSTRUMENT. Single Channel DC Power Supply SL Series Operation Manual V1.0

Reproduction or other use of this Manual, without the express written consent of Vulcan, is prohibited.

ISO-TECH IPS1810H and IPS1603D DC power supply ISO-TECH IPS 1810H et IPS 1603D Alimentation électrique c.c.

SD Bendix ET-2 Electronic Treadle DESCRIPTION OPERATION

Mid-West Instrument. Series 700 "Wet/Wet" Installation and Operating Instructions. Differential Pressure Transmitter

AEROMOTIVE Part # L Mustang Digital FMU INSTALLATION INSTRUCTIONS

Stay-IN-Play with Panic Stop Braking

Techcon Systems TS5000 Series Rotary Valve

INSTRUCTION MANUAL Model 1743B

IDEAL Stripmaster Model 950 Wire Stripper #45-950

PORT-A-WEIGH CRANE SCALES

OFI MODEL 130 HTHP BENCHTOP CONSISTOMETER INSTRUCTIONAL MANUAL

Config file is loaded in controller; parameters are shown in tuning tab of SMAC control center

10 PSE53 0 M5. Port size. M5 x 0.8 ø6 reducer 1/4-inch reducer. the cable at the time of shipment. 10-PSE to -101 kpa

Applied BioPhysics Inc

EP-8000 Series Electro-Pneumatic Transducers

SD Bendix TC-4 Modulating Control Valve TYPICAL PIPING DIAGRAM EXHAUST PORT DELIVERY PORT DELIVERY PORT FIGURE 1 SUPPLY PORT FIGURE 2

INSTRUCTIONS. Owner's Manual. Ionizing Air Nozzles Models AN-2 and AN-6

ENC 150 REFERENCE MANUAL ACU-RITE

SETRA Operating Instructions Series DPT 230 Pressure Transducers

PRODUCT SELECTION GUIDE 651, 1651, 153, 253, 653, and heated valves. Pressure Control Techniques. Dynamic Range

The Streaker Air-Particulate Sampler Instruction Manual

SATRON VTe pressure transmitter

Transcription:

Model P720 Peristaltic Pump Operation Manual NOTE: This pump is a laboratory device. It is not intended for use on humans. Instech Laboratories, Inc. cannot assume liability from improper use of its products.

Instech s Model P720 pump is a full-featured, miniature peristaltic pump designed specifically for low flow laboratory applications. Instech s wide variety of pump tube sets let you configure this pump to run at flow rates from 0.2 to 180 ml/hr,* to work with a variety of solutions, and to pump in single or dual channel mode. The Model P720 can operate as a stand-alone pump or as an element in closed loop control applications using the external speed control input. The pump has an internal battery that will operate the pump continuously for up to 30 hours if the power should fail or if you just want to move the pump around your lab without turning it off. This pump s circuitry has been designed to minimize electromagnetic radiation, making it ideal for use near sensitive microelectrodes. For quietest operation, run the pump using the internal battery. * For the base model with a 900:1 motor gear ratio. Other motors are available for other flow rate ranges. 1

Set-up Check for signs of shipping damage. You should have received: 1... Model P720 pump 1... Wall mounted 15V DC power adapter 1.... 9V lithium battery 1... 3.5mm stereo jack (for external speed control) Order tube sets separately. Motor run/stop Fine speed control Monitor output and external analog control input use stereo jack for connection Pump runs at full speed while pressed Speed source selector (set to INT for normal use) Coarse speed control Power on/off (Red LED on pump head indicates power on) Input for 9VDC power adapter (does not charge battery) Model P720 pump controls Battery Installation 1. Place POWER switch in off position (out). 2. Remove screw holding access cover on underside of pump and remove plate. 3. Withdraw connector and attach to battery terminals. A lithium U9VL is preferred due to its long shelf life and higher capacity (about twice the operating time as an alkaline) although an alkaline will suffice. 2

4. Make sure that the removal ribbon is below the battery. 5. Place the battery into the compartment and replace access plate. Testing Battery Backup Operation 1. Place speed source selector in INTernal position. 2. With no external adapter attached, turn on POWER switch and check pump end for illumination of red LED. 3. Press PURGE. The rotor should turn at full speed. 4. Set speed to some value other than zero and turn on motor by pressing the RUN/STOP button. 5. While motor is running, check that the amber LOW BAT- TERY LED has not come on (battery voltage below 7.5V); if so, replace battery. Pump Tube Installation 1. Slip the tubular portions extending from the bottom of the connector blocks into the mounting holes with the silicone tube just above the rotor. 2. Actuate the rotor, using the PURGE button, while guiding the tubing down and around the rotor with your finger (see figure below). 3. Press in both connectors so that they align with the square depressions in the pump. 4. Again press PURGE button to check that the tube has been correctly installed and that the amber Kapton tape has not been displaced. There will be slack in the tape as the rotor turns; this is normal. 3

Pump tube installation Pump Tube Removal 1. Press the purge button. 2. Lift the input side of the tube out of the holder. 3. As the rotor turns, lift the input side until the entire tube has disengaged. 4. Remove the output side from its holder. 4

Operation Stand Alone Operation 1. Insert the power jack into the pump first, then plug the 9V DC wall mount supply into an AC outlet. 2. Press in the pump POWER switch. 3. Attach inlet and outlet lines as required. Due to the low flow rates, it is usually best to attach the lines to the pump tube connector, fill the system, clear any air bubbles, pinch off the line to stop any flow and then install the pump tube into the pump as described above. The rotor will prevent flow when it is not turning. Pump tube installation may be performed without the external supply if it is more convenient. 4. Set desired flow rate using the two setting control knobs in conjunction with previously obtained calibration plot of flow vs. Dial Settings or MONITOR Voltage (see Calibration). 5. Check that SPEED SOURCE is in the INTernal position. If this switch has inadvertently been moved to the EXTernal position without an external input the pump will not run or respond to dial settings. 6. Press MOTOR RUN/STOP button to start pumping. Use this button to start and stop the pump rather than the POWER; it provides more rapid starts and stops. External Speed Control In this mode you will be supplying an analog voltage to control the speed of the pump. Bi-directional control is possible using this mode. The MOTOR RUN/STOP behaves normally. Set the SPEED SOURCE to EXTernal and apply the voltage via the center ring of the 3.5 mm stereo phono jack input at the top of the control panel. 5

EXTspeed in input GND Monitor voltage Out. Stereo jack connections for EXTernal speed control The control voltage passes through the speed control potentiometers and can be attenuated via the knob settings. This is a useful feature when operating more than one pump from a common control line since it allows individual speed adjustment for each pump. It is also useful when a digital level is used as a control voltage. The input parameters are as follows: Ensure that maximum MONITOR VOLTAGE (after knob attenuation) does not exceed ±1.75 volts. An input of +1.5V will produce a MONITOR voltage of about 1.75V when the dials are at 100 and 10. Zero volts = Zero flow rate (actively controlled). Note: TTL 0 state may not be 0 volts. CMOS is usually close enough to work directly. Positive Control voltage will cause the rotor to rotate clockwise (outflow will be on the top). Negative control voltage will cause the rotor to rotate counterclockwise (outflow on the bottom). To establish the maximum dial setting (assuming you desire full motor speed at your full peed signal): 1. Set Speed Source to EXT. 2. Apply power and press Power Switch IN. 3. Turn dials to 0. 4. Apply the maximum control signal that your system will deliver. Increase the dials until the MONITOR voltage reaches a maximum of 1.75V. 6

5. You may now perform a calibration of Flow vs. Monitor voltage as detailed below by either varying the incoming signal or with a constant input and varying the dials. Remember not to exceed the values determined in step 4 above. 6. Turn on the MOTOR RUN/STOP switch. You may leave the switch in this position and stop the pump by applying zero volts to the control input. Calibration Instech s P720 peristaltic pumps use tube sets of different sizes to cover the range of flow rates. The base model P720, with a motor that has a 900:1 gear ratio, will have flows from approximately 0.2 to 180 ml/hr (see chart below). Other models, such as the P720/66, /10K or /37K will have different ranges as shown in the spec sheet posted on the Instech website. To determine the flow rate at a given rotor speed you will need to calibrate your pump. We have designed our pumps so that the relationship between the rate setting on the controller and the rotor s speed is linear; therefore, in most cases you only need to perform a single-point calibration. For highest accuracy, we recommend that you calibrate each pump tube that you use, since tubing ID can vary from lot to lot. Approx. Flow Rate (ml/hr) 200.093" ID 180 160 140 120 100.062" ID 80 60 40.031" ID 20.020" ID.015" ID 0 0 10 20 30 40 50 60 70 80 90 100 110 Dial Setting (INTernal speed control) 7

1. Attach either the inflow or the outflow tube to a container on a balance, or one whose weight is precisely known. Ensure that all the air has been removed from the lines. 2. Set the pump dials to 110 to run the motor at maximum speed (coarse speed control: 100, fine speed control: 10), and turn on the pump motor. (Alternatively, when using the external speed control, or when you need more precision, you may calibrate vs. Monitor Voltage instead of dial settings. To read the Monitor Voltage connect a digital voltmeter between ground and the tip of the 3mm stereo jack plugged into the monitor jack.) 3. Collect or withdraw a timed sample, typically for 10 minutes. The total delivered volume upon which the calibration is based should exceed 0.5 ml (approximately 6 minutes when using the smallest tubing), assuming that the sample is being weighed with a resolution of 1 mg. 4. Weigh the sample and calculate the actual flow rate. Flow rates should be linear with dial settings between 3 and 110. Reservoir Scale Tips for Most Accurate Calibration Calibrating the pump by measuring the sample in a graduated pipette is usually less accurate than weighing the sample as described above. 8

When using new tube sets, run the pump at full speed for 20 to 30 minutes to allow the pump tube to stretch into its final shape. Use the same liquid that you will be using under actual operating conditions. When calibrating at very low flow rates, beware of evaporation. Use a covered container or one with a small surface area. If possible, simulate the pressure differences across the pump tube that will be experienced under actual operating conditions. Increased back pressure on the outflow side will cause a slight increase in delivery rate due to tubing dilation, though this effect is usually less than 1%. Replacement Parts Kapton Strips This amber strip can reduce tube wear and minimize the tendency for the peristaltic action to walk the tube through the pump, which can stretch the tube and alter the flow rate calibration. The strip should never be tight around the rotor. Replacement strips area available specify part number KSK. In many cases the kapton strips may not be necessary. Tube Sets Tube sets will typically last about one month under continuous operation. Dual tube sets place greater stress on the pump motor than do single tube sets, and thus they may shorten the life of the motor. To specify a tube set, first choose the size of tube you need based on your expected flow rates. Next choose the tube material and inlet and outlet connectors using the table below. When ordering, give Instech a part number that specifies: inlet connector tubing outlet connector. For example, LL-020S-22 specifies a single channel.020 silicone tube with a male Luer lock inlet connector and a 22 gauge hypodermic tubing outlet connector. Note that 9

you can have different inlet and outlet connectors on the same tube set. Call for current prices. DUAL TUBE SET WARNING: Dual channel tube sets, particularly the 062 size, place more stress on the pump motor than do single channel tube sets, which will shorten the life of the pump. Pumps with spur gearheads (P720/37K, P720/10K and P720) are more susceptible to this stress than are pumps with planetary gearheads (P720/66). In addition, dual 062 tube sets make contact with the sides of the pump rotor, which will cause those tube sets to wear faster than other sizes. 10

Available tube set materials, sizes and connectors Tube size (ID) Material Infusate.015".020".031".062".093" Silicone Saline, most drugs 015S 020S 031S 062S 093S C-FLEX IV diets with fats - 020C 031C 062C 093C VITON Petroleum-based fluids - 020V - 062V - Channel s Inlet and outlet connectors.015".020".031".062".093" Single 22 gauge tubing 22 - - - Single 20 gauge tubing 20 - - - Single.062" ID barb (soft BS plastic) Single Male Luer lock LL Single Female Luer lock FL Single.093" ID barb (soft 93 plastic) Dual 22 gauge tubing D22 - - - Dual 20 gauge tubing D20 - - - Dual.062" ID barb (soft plastic) DBS - - VITON is a registered trademark of DuPont Dow Elastomers LLC. C-FLEX is a registered trademark of Consolidated Polymer Technologies, Inc. Tygon is a registered trademark of Norton Performance Plastics Corporation. 22 22 gauge tubing 20 20 gauge tubing BS.062 ID barb Fits PE50,.020 Tygon Fits PE100,.030 Tygon Fits.062 Tygon LL Male Luer lock FL Female Luer lock 93.093 ID barb Fits female Luer,.093 Tygon Fits male Luer lock Fits.093 Tygon D22 Dual 22 gauge tubing D20 Dual 20 gauge tubing DBS Dual.062 ID barb Fits PE50,.020 Tygon Fits PE100,.030 Tygon Fits.062 Tygon Tube Set Connectors 11

Accessories Instech also offers a range of accessories and replacement parts for its peristaltic pumps. Call for current prices. Part Number Description P720/RMC Rod mounting clamp. Attaches P720 and P820 pumps and controllers to standard rod mounting systems (including Instech s UNIMOUNT). P720/KSK Kapton strip replacement kit. 20 protective strips, 5 retaining clips and 1 installation tool. P720/BATT 9V lithium battery for P720 pump. Specifications Rotor type Rotor speed Power supply voltage RPM supply sensitivity Typical operating current single tube Typical operating current dual tube Typical idle current Monitor voltage (INT) Nominal external voltage (EXT) Recommended battery Alternative battery Battery voltage triggering amber Lo Bat LED Size (WxHxD) Weight Typical repeatability ± 3% Linearity vs. dial setting ± 3% Accuracy ± 5% Maximum pressure.015 -.020 ID tube Maximum pressure.031 -.093 ID tube Printed March 2017 7700-05-0070rev01.doc 3 roller.4 14 RPM +8 to 15 V DC.08 %/Volt 25 ma 30 ma 14 ma 0 to ± 1.46 VDC ±1.5 to ±10 VDC Lithium U9VL Standard 9V alkaline ~7.5 V 2.5 x2.25 x4 1 lb 20 PSI 5 PSI 12

Instech Laboratories, Inc. Instech has been a leading provider of instruments for medical and biological research for over 40 years. Our reputation for quality and reliability is recognized by research facilities, universities and a wide range of companies throughout the world. Our design and manufacturing capabilities include: Small fluid pumps Continuous animal infusion systems Automated blood sampling systems Dissolved oxygen measurement systems Motor controllers For more information on the complete line of Instech systems and custom products, call us at 800-443-4227 or visit our website at www.instechlabs.com. The equipment behind the science. Instech Laboratories, Inc. 450 South Gravers Road Plymouth Meeting, PA 19462 800-443-4227 610-941-0132 FAX 610-941-0134 EMAIL support@instechlabs.com WEB www.instechlabs.com