Micro-OPLC Installation Guide

Similar documents
SBP2 Pendant Pushbutton Stations Installation Instructions

User Manual. T6 Tachometer. Online: Telephone: P.O. Box St. Petersburg, Florida 33736

Grapple Kit Install & Grapple Bucket Manual

Level Alert Model Multi-Switch Liquid Level Sensor. Assembly and Installation Instructions

3000RS PRECISION RESISTANCE STANDARD 3000 PRECISION SERIES LABORATORY REFERENCE STANDARDS

Model NTX7 Series Automatic Battery Charger User s Manual Rev. 1.0 October 17, 2006

DC Master 24/ A

XW2R-COM. Common Terminals X W 2R - P D - COM. Space-saving and less wiring work of power supply wiring are achieved. Application Example

WEB CONTROL PRODUCTS

PD404-AN V analog control 4 Channel x 500 W Dimmer & Switch Packs ANALOG 0-10 V. Serial Number

NEW GEN OWNER S MANUAL

A2P Single Phase Automatic Industrial Battery Charger

Models DP10 & DP20 Series Low Voltage Disconnects User s Manual Rev. 1.1 October 31, 2007

Signal Conditioner WEB CONTROL PRODUCTS SC100 FORM NO. L B User Manual. MTY (81)

HIGH DUMP ROLL-OUT BUCKET

DUAL WIDEBAND AIR/FUEL RATIO GAUGE Product Numbers: GS-W702W_Dual, GS-C702W_Dual, GS-T702W_Dual

Factory Authorized Mechanism Enhancement (FAME)

Mechanical Spiral Sensor

CM52 Network Protector with Arc Flash Reduction Module

OWNER S MANUAL SUBMERSIBLE UTILITY PUMP

SB SWITCH CONTROL BOX

Kompensator External Low Voltage Heating Cable System

For a 25 Amp Circuit with a 10% Voltage Drop, we recommend the following [but please follow all local electrical codes]: 50 [15.2] 8 [8.

INDUS rail /

3M Cold Shrink QT-III Silicone Rubber Three-Core Termination Kits

MACP TB. 23 db Coupler MHz Rev. V1. Features. Functional Schematic. Description. Pin Configuration 4. Ordering Information 1,2

3M Cold Shrink Silicone Rubber Termination QT-III 7600-S-3G Series Three-Core Outdoor Termination

OWNER S MANUAL SELF-PRIMING PORTABLE UTILITY PUMP

LT-EL138 LED Flashlight

Instruction Booklet for the Installation, Operation and Maintenance of Type 5-15 kv VCP-WG Vacuum Circuit Breaker 4000A MiniMod

RP Instruction Manual

Appendix: Safety and application notes for... 15

MANUAL Model: PT 12/24-60 Solar Converters Inc. - Rev. F

Installation Manual Model 3800/3810

Model HPX60 Series Automatic Battery Charger User s Manual Rev. 1.0 October 17, 2006

TO AVOID DOING IRREPARABLE DAMAGE TO DRIVE CIRCUITRY NEVER APPLY AC POWER DIRECTLY TO LED LIGHTBOXES!

Customer Support

Head-separated Digital Pressure Sensor DP5 SERIES DPH SERIES

VTC1000 Series Voltage Converter. Installation & Operation Manual

EVS RP6020. Instruction Manual

User s Manual. ClipperCreek, Inc. Innovative Infrastructure for Electric and Hybrid Vehicles. Model PCS-15

RANGE HOODS USER INSTRUCTIONS

Installation & Operators Manual

OBAE, OBAEXU, ON BOARD Battery Chargers

3M Cold Shrink Silicone Rubber Outdoor Termination Kit QT-III 7600-S-3W Series

INSTALLATION AND MAINTENANCE MANUAL FORM #PM-126 REV A 12/09

FX2N-2LC SPECIAL FUNCTION BLOCK

18642, INSTALLATION INSTRUCTIONS

USER S MANUAL GPC SERIES LOW VOLTAGE DISCONNECT. Galley Power LLC.

Installation Instructions for KPS and KPH Circuit Breakers and Molded Case Switches

DC TO AC POWER INVERTER PWRIC150012W INSTRUCTION MANUAL

Broadband PowerShield. External Battery Pack 20 Ah 12 V Battery. User Manual

Contactor Combiner Box Installation Manual

Dimensions 12/800N 12/1200N D. DC to AC Power Inverters. OWNERS MANUAL for Models: OWNERS MANUAL April ISO 9001:2000 Certified Company

Dimensions: [mm] Recommended Hole Pattern: [mm] Pattern Properties: Article Properties:

60 PSI Boost Gauge. For Product Numbers: MT-DV01_60, MT-WDV01_60

OC Automation Converters Series. Electronic Industries Alliance (EIA) interface converter series for serial communication devices

Cold Shrink - Silicone Rubber QTII(X)4S-32H Series Cable Termination Instructions

Disconnect Combiner Box Installation Manual

18673, INSTALLATION INSTRUCTIONS

Instructions for VCP-W Simple Electrical Ground & Test Device (SEG&TD) with simplified interlock scheme - bottom terminal set version

8300 Series Installation Guidelines

Heavy Duty Four Wheeled Walker

DC TO AC POWER INVERTER PWRINV150W INSTRUCTION MANUAL

Enhanced Mini Phantom

User Guide IGD Series

Installation Instructions

WELDING INVERTER. PEGAS 160 E Smart PEGAS 200 E Smart OPERATING MANUAL. ALFA IN a.s. PEGAS E Smart Manual EN 04

Do-It-Yourself Battery Pack

SENSE SERIES SPEAKERS

FOG Hog Grease Interceptor System Installation & Service Manual FOR USE WITH FOGHog FH-20, FH0-35, FH-50, FH-75, and FH-100

Installation Instructions for R-Frame G-Series (RG) 310+ Trip Unit

Accessories for Wind Power Inverter WINDY BOY PROTECTION BOX 400 / 500 / 600

Straight-Bore Clutch LSCC-32, 44, 54

G3PE-Single-phase. Solid State Relays for Heaters

USB Charge Port Installation Instructions

EBG Series Surface Preparation Machines

BroadBand PowerShield. 20 AHr Battery. User Manual

User s Manual and Operating Instructions

CCP2-FLR1-21_ flange-rod operating mechanism

VTC610 Series Voltage Converter. Installation & Operation Manual

Safety Sentry Electronic Breakaway Switch

INSTALLATION INSTRUCTION & OWNER S MANUAL

HYGRODYNAMICS DIGITAL DEW POINT MONITOR PC BOARD MODEL 6392N & 6392N2 TABLE OF CONTENTS

QPET, QPETXU Battery Chargers

i n s t r u c t i o n m a n u a l

3M Cold Shrink QT-III Silicone Rubber 3/C Cabinet Mount Termination Kit

M Series External Battery Frame. User Guide

DALI 650mA LED Driver

MAINFRAME HOT RUNNER TEMPERATURE CONTROL SYSTEMS. Instruction Manual

AEROMOTIVE Part # & Mustang 5.0L Stealth Fuel System Kit INSTALLATION INSTRUCTIONS

THE EXTREME BATTERY CHARGER

CLEAN ROOM DEVICES, LLC "WHERE TUBING AND FITTINGS COME TOGETHER"

DODGE CUMMINS MK-2 Micro-Kleen System

Smile 11 RA/-B Smile 12 RF/-G Reset button

SUPER PUMP OUT SYSTEM

MIL-24/2600Q MIL-24/3200DQ

A Member of the. Integrated Metering Technologies

INSTRUCTION MANUAL WARNING

GEatom306KHF-5U Three-phase Grid-Tied Battery Inverter. Version 1.1. Global Mainstream Dynamic Energy Technology Ltd. 1

Transcription:

4 mm (0.157") 117 mm (4.606") 7.5 mm (0.295") Jazz OPLC Micro-OPLC Installation Guide 6 Digital Inputs, 4 Relay Outputs 6 Digital, 2 Analog/Digital, 2 Analog Inputs, 6 Relay Outputs Before using this product, the user must read and understand this document. For additional information regarding this product, refer to the user guide and technical specifications. All examples and diagrams are intended to aid understanding, and do not guarantee operation. Unitronics accepts no responsibility for actual use of this product based on these examples. Please dispose of this product according to local and national standards and regulations. Only qualified service personnel should open this device or carry out repairs. Failure to comply with appropriate safety guidelines can cause severe injury or property damage. Do not attempt to use this device with parameters that exceed permissible levels. To avoid damaging the system, do not connect/disconnect the device when power is on. Environmental Considerations Do not install in areas with: excessive or conductive dust, corrosive or flammable gas, moisture or rain, excessive heat, regular impact shocks or excessive vibration. Ventilation: 10mm space required between the OPLCs top/bottom edges & enclosure walls. Do not place in water or let water leak onto the unit. Do not allow debris to fall inside the unit during installation. Mounting Dimensions 147.5 mm (5.807") 12 mm (0.472") 16.8 mm (0.661") 85.7 mm (3.374") 46.6 mm (1.835") 13.2 mm (0.52") 113.7 mm (4.476") Add-on modules Take into account that installing an add-on module requires sufficient clearance space. During installation After installation 72 mm (2.835") 27.5 mm (1.083") 35.8 mm (1.409") 38 mm (1.496") Unitronics 1

53 mm (2.087") 35 mm (1.378") 05/10, DIN-rail mounting Snap PLC onto the DIN rail Panel mounting Cut-out: 117 x 89mm (WxH) 4.606 x 3.504 Panel 5mm (max) 0.197" (max).. Gasket Wiring Note: All diagrams are based on the rear view of the OPLC. Do not touch live wires. Install an external circuit breaker. Guard against short-circuiting in external wiring. Use appropriate circuit protection devices. Unused pins should not be connected. Ignoring this directive may damage the device. Double-check all wiring before turning on the power supply. To avoid damaging the wire, do not exceed a maximum torque of 0.5 N m (5 kgf cm). Do not use tin, solder, or any substance on stripped wire that might cause the wire strand to break. Install at maximum distance from high-voltage cables and power equipment. Use crimp terminals for wiring; use 26-12 AWG wire (0.13 mm 2 3.31 mm 2 ). 1. Strip the wire to a length of 7±0.5mm (0.250-0.300 inches). 2. Unscrew the terminal to its widest position before inserting a wire. 3. Insert the wire completely into the terminal to ensure a proper connection. 4. Tighten enough to keep the wire from pulling free. Input or output cables should not be run through the same multi-core cable or share the same wire. Allow for voltage drop and noise interference with input lines used over an extended distance. Use wire that is properly sized for the load. Inputs 1. Both and comprise I0-I5; these digital inputs are arranged in a single group. Via wiring, the entire group may be set to either pnp or npn. The following information concerns. In addition to I0-I5, these comprise the following: 2. I6 and I7 may be wired as either digital or analog inputs. These may be wired as either: npn digital inputs pnp digital inputs analog (voltage) inputs In addition, 1 input may be wired as a pnp input, while the other is wired as an analog input. Note that if 1 input is wired as an npn input, the other may not be wired as an analog input. 3. AN0 and AN1 are analog (voltage) inputs. 2 Unitronics

, 05/10 I/O Configuration Digital Inputs, Controller s Power Supply Input wiring (I0-I5), npn (sink) Input wiring (I0-I5), pnp (source) Input wiring (I0-I5), npn (sink) Input wiring (I0-I5), pnp (source) Input wiring (I6-I7), npn (sink) Input wiring (I6-I7), pnp (source) Unitronics 3

05/10, Digital Outputs Output wiring Increasing contact life span To increase the life span of your contacts and protect the unit from potential damage by reverse- EMF, connect: A clamping diode in parallel with each inductive DC load An RC snubber circuit in parallel with each inductive AC load 4 Unitronics

, 05/10 Analog inputs Note: Shields should be connected at the signal source. Analog Input wiring, current (JZ10-11-R16 only) 2 or 3-wire, AN0 and AN1 4-wire, AN0 and AN1 Analog Input wiring, voltage Note: If either I6 or I7 is wired as an npn digital input, the remaining input may not be wired as an analog input., AN2 and AN3 JZ10-11-R16V, AN0 and AN1 The information in this document reflects products at the date of printing. Unitronics reserves the right, subject to all applicable laws, at any time, at its sole discretion, and without notice, to discontinue or change the features, designs, materials and other specifications of its products, and to either permanently or temporarily withdraw any of the forgoing from the market. All information in this document is provided "as is" without warranty of any kind, either expressed or implied, including but not limited to any implied warranties of merchantability, fitness for a particular purpose, or non-infringement. Unitronics assumes no responsibility for errors or omissions in the information presented in this document. In no event shall Unitronics be liable for any special, incidental, indirect or consequential damages of any kind, or any damages whatsoever arising out of or in connection with the use or performance of this information. The tradenames, trademarks, logos and service marks presented in this document, including their design, are the property of Unitronics (1989) (R"G) Ltd. or other third parties and you are not permitted to use them without the prior written consent of Unitronics or such third party as may own them DIG-JAZZ-R1X-V 05-10 Unitronics 5