EX100/200-Series INSERTION MAGNETIC FLOW METER INSTRUCTIONS EX110 EX210 EX150 EX :2008 ISO CERTIFIED COMPANY

Similar documents
EX80-Series ELECTROMAGNETIC FLOW SENSOR INSTRUCTIONS EX81 EX82 EX :2008 ISO CERTIFIED COMPANY

EX100/200 Series. Insertion Magnetic Flow Meter Instructions. EX11x EX21x. EX15x EX25x PROUDLY MADE IN THE USA

ARCHIVED. EX80 Series. (Includes Dates 6/28/05 to 10/06) EX81 EX82

EX80 Series EX81 EX82. E X 8 0 S E R I E S E l e c t r o m a g n e t i C F l o w s e n s o r i n s t r u c t i o n s. The Leader in Flow Meter Value.

TX100/200-SERIES INSERTION TURBINE INSTRUCTIONS TX101/201 TX115/215 ISO 9001:2008 CERTIFIED COMPANY

SERIES TBS INSERTION TURBINE TBS-0XX TBS-1XX

TX115/215 Hot-tap Insertion Turbine Instructions

TX101/201 Insertion Turbine Instructions

TX 115/215 Hot-tap Insertion Turbine Instructions

TX800-Series FLOW SENSOR INSTRUCTIONS. TX81x TX82x 9 001:2008 ISO CERTIFIED COMPANY TX800-SERIES FLOW SENSOR INSTRUCTIONS

TX100/200-SERIES INSERTION TURBINE. T X / S E R I E S I N S E R T I O N T U R B I N E instru c tions TX101/201 TX115/215

TX101/201 Insertion Turbine Instructions

WMX-series MUNICIPAL/INDUSTRIAL MAGMETER INSTRUCTIONS

TX80-Series FLOW SENSOR INSTRUCTIONS TX81 TX :2008 ISO CERTIFIED COMPANY TX80-SERIES FLOW SENSOR INSTRUCTIONS

EX800-Series. Electromagnetic Flow Sensor Instructions PROUDLY MADE IN THE USA

IP800-Series FLOW SENSOR INSTRUCTIONS IP810 IP :2008 ISO CERTIFIED COMPANY IP80-SERIES FLOW SENSOR INSTRUCTIONS

IP80-Series FLOW SENSOR INSTRUCTIONS IP81 IP :2008 ISO CERTIFIED COMPANY IP80-SERIES FLOW SENSOR INSTRUCTIONS

SERIES FLMG MUNICIPAL/INDUSTRIAL MAGMETER INSTRUCTIONS

IP800-Series. Insertion Paddlewheel Flow Sensor Instructions PROUDLY MADE IN THE USA

IP800-Series. Insertion Paddlewheel Flow Sensor Instructions PROUDLY MADE IN THE USA

Shop online at omega.com For latest product manuals: omegamanual.info

IP800-Series FLOW SENSOR INSTRUCTIONS IP810 IP :2008 ISO CERTIFIED COMPANY IP800-SERIES FLOW SENSOR INSTRUCTIONS

Compu-Flow. Electromagnetic Insertion Flow Meter. Compu-Flow EXM MAG

AG2000 IRRIGATION MAGMETER INSTRUCTIONS

WMP-Series PLASTIC-BODIED MAGMETER INSTRUCTIONS 9001:2008 ISO CERTIFIED COMPANY WMP-SERIES PLASTIC-BODIED MAGMETER INSTRUCTIONS. 3 inch.

EM101 LOW FLOW MAGNETIC FLOWMETER INSTRUCTIONS

Pipe fi ttings MUST be installed by a certifi ed welder only. Signet will not assume liability of any kind for improper fi tting installations.

SES. Stainless Single-Jet Meter Instructions PROUDLY MADE IN THE USA

EM 101 EM EM EM GENERAL INFORMATION. SPECIFICATIONS MATERIALS Wetted Materials - FLOW RANGE

Pipe fittings MUST be installed by a certified welder only. +GF+ SIGNET will not assume liability of any kind for improper fitting installations.

Signet 2517 Brass Paddlewheel Flow Sensor * *

Pipe fi ttings MUST be installed by a certifi ed welder only. Signet will not assume liability of any kind for improper fi tting installations.

SeaMetrics Flow Meters and Flow Computers

PE202. Low Flow Magmeter Instructions. Precision Flow Measurement An ONICON Brand PROUDLY MADE IN THE USA

LEVEL AND FLOW MEASUREMENT WS131 FLOW METER USER MANUAL.

Insertion turbine INSTRUCTION SHEET. TECHNICAL PRODUCT

S-Series. Low Flow Meter Instructions SPX SPT. Precision Flow Measurement An ONICON Brand PROUDLY MADE IN THE USA

WMX-SERIES Flanged Magmeter

BI-DIRECTIONAL INSERTION FLOW TRANSDUCER

AG2000 Irrigation Magmeter

Sidel Therm & CO 2 Counter Instruction & Installation Manual

F-4600 INLINE ULTRASONIC FLOW METER Installation and Operation Guide

FLS F6.60 MAGMETER FLOW SENSOR INSERTION FLOW SENSORS APPLICATIONS MAIN FEATURES

BI-DIRECTIONAL INSERTION METER

MFM220 & MFM220DC Plastic-Bodied Magmeter

Hydro-Flow Model 3100 Retractable Insertion Vortex Flowmeter Installation and Operation Manual

imag 4700 SERIES FLANGED MAGMETER

Instructions EM 101 Low Flow Electromagnetic Flow Meters

W91/W94 Series TEMPERATURE REGULATORS. Self-Operated Temperature Regulators. Design & Operation W91 Non-Indicating W94 Dial Thermometer

Hydro-Flow Model 3100

Hydro-Flow Model 2200 Fixed Insertion Vortex Flowmeter Installation and Operation Manual

TR-QS Wafer-Style Turbine Flow Meters Installation, Operating & Maintenance Manual

Signet 2552 Metal Magmeter

TURBINE METERS - WP Series

FPD1001B thru FPD1003B, FPD1102B and FPD1103B, FPD1201B thru FPD1203B SERIES LOW FLOW Positive Displacement Flowmeters

Hydro-Flow Model 2200 Installation and Operation Guide B

Signet 2552 Metal Magmeter

M SERIES Multi-Jet Cold Water Meter

MODEL 1100 TURBINE FLOW METER

SITRANS AS 100. Instruction Manual September 2001 ITRANS AS 100

DIGITAL FLOWMETER AND PRESSURE INDICATOR MODEL FPA400

FPD1001 thru FPD1003, FPD1102 and FPD1103, FPD1201 thru FPD1203 (includes -R Option) Positive Displacement Flowmeters

FLOWX3 F3.20 High Pressure Paddlewheel Flow Sensor MAIN FEATURES APPLICATIONS OPERATING PRINCIPLE

Flow Meter & Control Catalog

Operating Instruction for Plastic Vortex Flow Transmitter. Model: UV

Chapter Page. 1 Introduction Description 1

* * Rev. F 03/16 Operating Instructions

ISTEC MAGNETIC METERS

FIXED DEPTH INSERTION METER INSTRUCTIONS

Signet 2552 Magmeter. English * * Specifications. Safe to operate Hot-tap

G2 Industrial Grade Meters

INLINE Flow sensor for hazardous area II 1 G/D - II 2 D - II 3 GD - I M1

Ensuring Premium Performance with Foxboro I/A Series Pulsed dc Magnetic Flowmeters

Paddle Wheel Turbine Flow Meters Installation, Operating & Maintenance Manual

Product Manual. EX40, Version Last Updated: 11/7/16. Product Description:

Model 1100 Turbine Flow Meter

Product Data Sheet 2012 Rev 5 FLOWMETRIX SA SAFMAG Electromagnetic Flowmeter Doc Date

F111.X Flow Sensor for Hot Tap Installation INSTRUCTION MANUAL. 1. Introduction Safety Instructions Unpacking Description.

Signet 2536 Rotor-X Paddlewheel Flow Sensors

Manifold QF. Contents. Description. Installation & Setup Guide. Safety 3. Introduction 3. Installation Standards 4. Specifications 5.

MFM300 Plastic-Bodied Magmeter

Installation, Operation and Maintenance Manual

Paddle Wheel Turbine Flow Meters Installation, Operating & Maintenance Manual

SIGNET 7002 Vortex Flow Sensor ENGLISH

Appendix. Clearance. Skewed profiles. Application Schematics

DIGITAL PRESSURE AND FLOW INDICATOR MODEL FPA500

* * Rev M 10/14 Operating Instructions

* * Rev /18 Operating Instructions

Operating and Installation Instructions

Installation & Operation Manual

INSTRUCTION MANUAL. 1. Introduction 2. Safety Instructions.. 2 Unpacking Description. 2. Main Features... 3 Technical Data...

HM860 FLOWMETER OPERATOR S MANUAL DO NOT USE OR OPERATE THIS EQUIPMENT UNTIL THIS MANUAL HAS BEEN READ AND THOROUGHLY UNDERSTOOD

Hydro-Flow 2200 Fixed Insertion Vortex Flow Meter

Positive Displacement Flowmeters GM020 series instruction manual

100 Series Flow Switches Technical Reference Manual

SCC Inc. FLMTR Series. Installation Instructions Document No. LV February 21, KT-BMK-PLC Gas Flow Meter Kits for Flow Totalization

Condensed Version of Operator s Manual For The VL600 Series Flowmeters

DIGIFLO ELECTRONIC FLOWMETER

C.W. COX COMPANY a product line of Perfecto Products, Inc

CIRCLE SEAL CONTROLS

Transcription:

EX100/200-SERIES INSERTION MAGNETIC FLOW METER INSTRUCTIONS EX100/200-Series INSERTION MAGNETIC FLOW METER INSTRUCTIONS EX110 EX210 EX150 EX250 9 001:2008 ISO CERTIFIED COMPANY

TABLE OF CONTENTS General Information General Information, Features, Specifications... Page 1 Installation Piping, Distorted Flows, Immersion, Positioning the Meter... Page 2 Fitting Installation, Meter Installation... Page 3 Proper Depth Setting... Page 4 Dimension C, Pipe Wall Thickness... Page 5 Straight Pipe Recommendations... Page 6 Full Pipe Recommendations... Page 7 Electrical Connections General Electrical Guidelines,, Forward (and Reverse) Flow Output, Grounding Guidelines, Grounding Diagram... Page 8 Connections Diagrams Counter or PLC, A055 4-20 ma Output, FT520 Controller... Page 9 FT420 Display and Proportional Feed, FT420 & 4-20 ma Output, Dual FT420 Displays... Page 10 DL76 Data Logger, FT420/DL76... Page 11 Operation & Maintenance Zero Adjustment, Minimum Flow, Presence of Flow Indication, Filtering, Electrode Coating, Calibration ( K-Factor ), Flow Rates in Gallons Per Minute... Page 12 Troubleshooting Problems, Probable Causes and Things to Try... Page 13 TABLES, DIAGRAMS & CHARTS Features... Page 1 Distorted Flows, Positioning the Meter... Page 2 Meter Installation, Sensor Removal... Page 3 Proper Depth Setting... Page 4 Dimension C, Pipe Wall Thickness... Page 5 Straight Pipe Recommendations... Page 6 Full Pipe Recommendations... Page 7 Grounding Diagram... Page 8 Connection Diagrams: Counter or PLC, A055 4-20 ma Output, FT520 Controller... Page 9 Connection Diagrams: FT420 Display and Proportional Feed, FT420 & 4-20 ma Output, Dual FT420 Displays... Page 10 Connection Diagrams: DL76 Data Logger, FT420/DL76... Page 11 Zero Adjustment, Flow Rates in Gallons Per Minute... Page 12 Troubleshooting Problems, Probable Causes and Things to Try... Page 13

GENERAL INFORMATION, FEATURES and SPECIFICATIONS The complete lack of moving parts of the EX100/200-Series insertion flow sensor is the source of its reliability. Brass and stainless steel models withstand a variety of temperature, pressure, and chemical conditions. The EX-Series has no rotor to stop turning in dirty water and there are no bearings to wear out. A rapidly reversing magnetic field is produced in the lower housing. As the fluid moves through this field, a voltage is generated that is measured and translated into a frequency signal proportional to flow rate. This square wave signal can be sent directly to a PLC or other control or can be converted using any of the Seametrics family of indicators and converters. A modular system of electronics can be attached directly to the flow FEATURES Cable Strain Relief sensor or remotely mounted. The Seametrics FT420 provides full indication of rate and total, plus 4-20 ma output. The AO55 provides blind 4-20 ma output, and the DL76 is a battery-powered data logger. The adapter of the EX mates with a standard female NPT fitting, and can be directly threaded into ordinary saddles or threaded weld fittings. The EX115 and 215 include an isolation valve, allowing hot-tap installation, or installation and removal under pressure; a bronze ball valve is standard, with a 316 stainless steel valve option if needed. Reverse flow output and immersibility are optional. Housing Screw (connect ground to one) Cover or Electronics Module Lower Housing Brass or 316 Stainless Shaft Compression Nut Adapter mates with 1 1/2 FNPT threaded fitting EX110/210 Sensor Housing Electrodes and Cap EX150/250 Valve assembly for hot tap installation SPECIFICATIONS* Pipe Sizes Materials Shaft/Fitting Electrodes Electrode Cap Housing Valve Assembly (115/215 Only) O-Ring (115/215 Only) Full Low 3 to 48 (up to 72 optional) 316 SS or Brass Hastelloy PVDF Cast powder-coated aluminum Bronze (stainless optional) with bronze ball valve EPDM 12-25 Vdc, 250 ma 12-25 Vdc, 40 ma average with 250 ma peaks Flow Range Fitting Size Required Temperature Ambient Fluid Pressure Minimum Conductivity Calibration Accuracy Output 0.28 to 20 ft/sec (0.08-6.09 m/sec) EX110/210 EX150/250 1-1/2 FNPT 2 FNPT 0 to 160 F (-17 to 72 C) 32 to 200 F (0 to 93 C) 200 psi (13.8 bar) 20 microsiemens/cm /- 1% of full scale Square wave pulse, opto isolated, 550 Hz @ 20 ft/sec 6 ma max, 30 Vdc forward flow standard; reverse flow optional Empty Pipe Detection Software, defaults to zero flow *Specifications subject to change Please consult our website for current data (www.seametrics.com). Page 1

INSTALLATION Piping. For best results, the EX sensor should be installed with at least ten diameters of straight pipe upstream and five downstream. Certain extreme situations such as partially-opened valves are particularly difficult and may require more straight diameters upstream (see page 6 for straight pipe recommendations). POSITIONING THE METER Fair (Unacceptable position if air is present) DISTORTED FLOWS Distorted Flow Profile Faster Flow Causes Meter To Read High Best Position FLOW 10X 5X Fair (Unacceptable position if fluid contains sediment) Immersion. The 100/200-Series sensors are not designed for underwater operation. Even occasional immersion can cause damage. If occasional immersion, such as when a vault floods, then the -40 option, (immersion) is recomended. Chemical Injection or Fertigation. When any magmeter, by any manufacturer, is used in a chemical injection application (including fertigation), the chemical line must be placed downstream of the magmeter OR far enough upstream for complete mixing to occur before the fluid reaches the meter. When unmixed chemical or fertilizer alternates with water passing through the meter, the rapid changes in conductivity may cause sudden spikes and drops in the meter s reading, resulting in inaccurate measurement. The magmeter will restabilize, however, with a steady flow of fluid of uniform conductivity. Vertical flow in upward direction is the preferred installation orientation, since it improves low-flow performance and avoids problems with trapped air and sediment. Bottom, top, and vertical pipe installations are all acceptable if required by the piping layout. Caution: These flow sensors are not recommended for installation downstream of a boiler feedwater pump where installation fault may expose the flow sensor to boiler pressure and temperature. Maximum recommended temperature is 200 F. Caution: In chemical injection or fertigation applications, install chemical line downstream of magmeter, or far enough upstream to allow complete mixing of fluids before the meter. Page 2

INSTALLATION EX110/210 INSTALLATION Fitting Installation. EX110/210 adapters mate with a 1-1/2 female NPT pipe thread adapter fitting. Any fitting that provides the matching NPT female thread may be used. Installation procedure compensates for fitting height differences. Cut a minimum 1-3/4 hole in the pipe. If possible, measure the wall thickness and write it down for use in depth setting. Then install the threaded fitting (saddle, weldolet, etc.) on the pipe. Meter Installation. Loosen the compression nut so that the adapter slides freely. Pull the meter fully upward and finger-tighten the compression nut. Using a thread sealant, install the adapter in the pipe fitting. Do not overtighten. Now loosen the compression nut, lower the meter to the appropriate depth setting (see diagram and instructions that follow). Be sure flow is in the direction of the arrow on the housing. Tighten compression nut fully. Compression nut Adapter mates with FNPT threads EX150/250 INSTALLATION Hot tap EX meters are designed so they can be installed and serviced without depressurizing the pipe. Fitting Installation. The EX150 and 250 adapters mate with a 2 FNPT threaded fitting for compatibility with the 2 isolation valve. Any fitting that provides matching NPT female thread may be used. The installation procedure compensates for differences in fitting height. If initial installation is performed on an unpressurized pipe, cut a minimum 1-3/4 hole in the pipe. If possible, measure the wall thickness and write it down for use in depth setting. Then install the threaded fitting (saddle, weldolet, etc.) on the pipe. If it is necessary to do the initial installation under pressure, any standard hot tap drilling machine with 2 NPT adapter, such as a Transmate or a Mueller, can be used. Ordinarily, it is not necessary to use an installation tool, due to the small diameter tube the meter can be installed by hand at all but the highest pressures. Meter Installation. Remove the sensor unit from the valve assembly. Using a thread sealant, install the valve assembly on the pipe fitting. If the initial installation is a pressure ( hot ) tap, remove the 1-1/2 x 2 adapter bushing at the back of the valve. Thread the tapping machine on, open the valve, and tap using a minimum of 1-3/4 or maximum 1-7/8 cutter. After retracting the machine and closing the valve, reinstall the flow sensor. When the sensor is secure, open the valve and adjust depth setting (see diagram and instructions that follow). Be sure flow is in the direction of the arrow on the housing. Tighten locking collar and compression nut fully. Compression nut Locking collar 2 adapter removes to mount hot-tap machine Full-port 2 ball valve allows sensor removal Mates with 2 FNPT threads EX150/250 Sensor Removal Page 3

INSTALLATION PROPER DEPTH SETTING Depth Setting. It is important for accuracy that the sensor be inserted to the correct depth into the pipe. "D" 1. In Table 1, find Dimension C for your sensor model and pipe size. Subtract wall thickness of your pipe (Table 2) to find Dimension D. NOTE: When you calculate your K-factor as described on page 12, Dimension D will be given also. 2. Measuring from the outside of the pipe to the joint in the housing, as shown in the diagram, adjust the sensor to Dimension D and hand-tighten compression nut. Caution! Never attempt to remove a flow sensor when there is pressure in the pipe unless it is specifically designed for hot tap installation and removal. Loosen the compression nut slowly to release any trapped pressure. If fluid sprays out when removing the sensor, stop turning and depressurize the pipe. Failure to do so could result in the sensor being thrown from the pipe, resulting in damage or serious injury. 3. Align the conduit housing with the centerline of the pipe, as shown. Be sure the arrow on the housing points in the direction of flow. strain relief 4. Check Dimension D one more time. FLOW 5. Tighten the compression nut fully. Page 4

INSTALLATION TABLE 1: DIMENSION C NOMINAL PIPE SIZE 3 4 6 8 10 12 14 16 18 20 24 30 36 EX110 EX210 EX150 EX250 10.04 9.93 9.69 9.46 9.22 8.99 8.75 8.52 8.28 8.05 7.58 6.87 6.17 15.04 14.93 14.69 14.46 14.22 13.99 13.75 13.52 13.28 13.05 12.58 11.87 11.17 17.04 16.93 16.69 16.46 16.22 15.99 15.75 15.52 15.28 15.05 14.58 13.87 13.17 21.04 20.93 20.69 20.46 20.22 19.99 19.75 19.52 19.28 19.05 18.58 17.87 17.17 TABLE 2: PIPE WALL THICKNESS NOMINAL PIPE SIZE 3 4 6 8 10 12 14 16 18 20 24 30 36 PVC/Steel Sch. 40 PVC/Steel Sch. 80 Stainless Steel (10S) Stainless Steel (40S) Copper Tubing (Type L) Copper Tubing (Type K) Brass Pipe Duct. Iron (Class 52) 0.216 0.237 0.280 0.322 0.365 0.406 0.438 0.500 0.562 0.593 0.687 0.300 0.337 0.432 0.500 0.593 0.687 0.750 0.843 0.937 1.031 1.218 0.120 0.120 0.134 0.148 0.165 0.180 0.188 0.188 0.188 0.218 0.250 0.312 0.312 0.216 0.237 0.280 0.322 0.365 0.375 0.375 0.375 0.375 0.375 0.375 0.375 0.375 0.090 0.110 0.140 0.200 0.250 0.280 0.109 0.134 0.192 0.271 0.338 0.405 0.219 0.250 0.250 0.312 0.365 0.375 0.280 0.290 0.310 0.330 0.350 0.370 0.390 0.400 0.410 0.420 0.440 0.470 0.530 Page 5

INSTALLATION STRAIGHT PIPE RECOMMENDATIONS (X = diameter) 10X 5X Reduced Pipe Two Elbows In Plane 10X 5X Two Elbows, Out Of Plane 20X 5X 20X 5X Expanded Pipe 30X Spiral Flow Propeller Meter 50X Swirling Flow Page 6 Partially Open Butterfly Valve

INSTALLATION FULL PIPE RECOMMENDATIONS Possible Problem Better Installation Ensures full pipe Allows air pockets to form at sensor Possible Problem Better Installation Post-valve cavitation can create air pocket Keeps pipe full at sensor Possible Problem Better Installation Air can be trapped Allows air to bleed off Caution: These flow sensors are not recommended for installation downstream of a boiler feedwater pump where installation fault may expose the flow sensor to boiler pressure and temperature. Maximum recommended temperature is 200 F. Page 7

ELECTRICAL CONNECTIONS General Electrical Guidelines: Whenever possible avoid running control cables in the same conduit with or bundled with AC power. Using shielded cable, be sure to connect shield to ground at power supply end of the cable. Do not connect other end of shield. Avoid routing flow sensor cables in close proximity to a variable frequency drive. Recommended power and output wiring is shielded twisted pair 18-22 AWG control cable. Recommended voltage is 12-24 Vdc. Note that unregulated power supplies can vary from nameplate voltage by a considerable amount, especially with AC line voltage fluctuation. Therefore 24V power supplies must be regulated. See the Connections diagrams on the following pages for the appropriate terminals. : A 12-24 Vdc power supply capable of at least 250 ma current output is needed. Output: The standard output is pulses with flow in the forward direction (Reverse flow output is optional [-15] ). Electrically it is an open collector opto isolated switch. The output is not internally powered. Grounding Guidelines: For best results, use a good quality earth ground, such as metallic water piping or a driven ground, to ensure a good connection to earth ground and good noise suppression. If the flow sensor is installed in metallic piping, for optimum connection clamp wire to the piping a short distance to one side of the flow sensor using an electrical grounding clamp. Connect the wire to the earth ground and to one of the housing screws. For Non-Metallic Pipe: Connect one to the housing screws by wire to a good earth ground, such as metalic water piping or a rod driven into the ground. EX meters are usually unaffected by moderate levels of electrical noise. In some applications performance may be improved by taking the following steps: Use shielded twisted pair cable (Belden 8723 or equivalent above ground or Alpha 35482 or equivalent burial). Clamp a ferrite bead (Steward 28A2029-OAO or equivalent) on meter signal/power wire within 3/4 of the meter strain relief (tape or tie wrap in place if necessary). See diagram below. IMPORTANT - Connect the cable shield ground wire to ground, ONLY at power supply end of cable. Note: This output is limited to 6 ma at 30 Vdc maximum. GROUNDING DIAGRAM Earth Ground PLACE FERRITE BEAD HERE Housing Screw Metallic Pipe Grounding Clamp Page 8

CONNECTIONS DIAGRAMS COUNTER OR PLC 12-24 Vdc Forward Output (open collector) Reverse Output (Option -15 only) Max. 6 ma, 30 Vdc Max. 6 ma 30 Vdc COUNTER OR PLC DIGI- TAL INPUT EX-SERIES *See Dual FT420 Diagram for an example of bidirectional connections. AO55 4-20 ma OUTPUT 24 Vdc Forward Output Reverse Output (Option-15 only) EX-SERIES 9 8 7 0 5 6 Sensor *See Dual FT420 Diagram for an example of bidirectional connections. 1 4 2 3 9 8 7 0 4 5 6 1 2 0 3 9 8 7 5 6 1 4 2 3 FREQUENCY 9 8 7 0 5 6 1 4 2 3 S 4-20 ma AO55 24 Vdc 4-20 ma FT520 CONTROLLER FT520 24 Vdc EX-SERIES Out 12V SEN1 G SEN2 Forward Output Reverse Output (Option-15 only) *See Dual FT420 Diagram for an example of bidirectional connections. Page 9

CONNECTIONS DIAGRAMS FT420 DISPLAY AND PROPORTIONAL FEED 24 Vdc FT420 Forward Output Sensor Input S Scaled To Proportional Feed Metering Pump Reverse Output (Option-15 only) EX-SERIES *See Dual FT420 Diagram for an example of bidirectional connections. 4-20mA Pass-Thru FT420 DISPLAY AND 4-20 ma OUTPUT FT420 Forward Output Reverse Output (Option-15 only) *See Dual FT420 Diagram for an example of bidirectional connections. EX SERIES 24 Vdc 24 Vdc 4-20 ma Device (e.g. pump, PLC) Sensor Input 4-20mA S Scaled Pass-Thru DUAL FT420 DISPLAYS (Example of Bidirectional Connection) FT420 Pass-Thru 4-20mA 24 Vdc Sensor Input FT420 Scaled Forward Output Scaled Sensor Input Reverse Output (Option-15 only) 4-20mA Pass-Thru Page 10 EX-SERIES

CONNECTIONS DIAGRAMS DL76 DATA LOGGER DL76 12-24 Vdc Sensor Input Forward Output Reverse Output (Option-15 only) EX-SERIES *See Dual FT420 Diagram for an example of bidirectional connections. FT420/DL76 Forward Output Reverse Output (Option-15 only) EX-SERIES 24 Vdc Sensor Input S 4-20mA FT420 Scaled Pass-Thru Sensor Input S DL76 *See Dual FT420 Diagram for an example of bidirectional connections. Page 11

OPERATION & MAINTENANCE Zero Adjustment. When the EX100/200-Series meter is powered up and there is no flow, there should be no output pulses (or, if connected to the FT420, flow rate should read 0 ). If there are pulses, it may be necessary to adjust the flow meter under no-flow conditions after it has been installed. This should only be done if the indicated flow is low, near the lower cutoff. Status LED Zero Adjust Pins Status LED Zero Adjust Pins - - Forward Output To perform the adjustment, after determining that there is a full pipe with no flow, short between the two pins marked Zero Adjust. A red LED light will come on for approximately 50 seconds and then go out. The zero adjustment is completed. Minimum Flow. As with any other flow sensor, there is a rate below which the EX100-Series sensor cannot read. Check the table below for the minimum flow rate detectable by the sensor for a given pipe size. Presence of Flow Indication. To assist in troubleshooting, the Status LED has two blinking modes in normal operation. When there is no flow detectable by the meter (below minimum threshold) the LED blinks every 8.0 seconds. When there is detectable flow, the same indicator blinks every 3.0 seconds (s are being output when indicator is blinking every 3 seconds). 1 2 Max. 6mA 30Vdc 3 4 5 6 12-24Vdc Filtering. The software of the EX100/200-Series filters out electrical noise and averages sudden variations in the flow to smooth the output. It takes a matter of seconds for the flow sensor to get up to full output when it is powered up or when flow begins. Electrode Coating. Grease or other adhering, non-conductive materials can stop flow detection if the electrodes become heavily coated. To clean the electrodes, remove the sensor from the pipe and gently scrub the electrodes (three silver bumps) on the reading face of the flow sensor. A mild soap (dishwashing liquid for example) can be used to aid the cleaning process. Calibration ( K-Factor ). In order to properly process pulses from the flow sensor, a number must be entered into the control to which the sensor is connected. This number, called the K-factor, is the number of pulses the sensor puts out per unit of fluid passing through the pipe. It is normally provided for Seametrics sensors in pulses per gallon, and can be ascertained by using the K-Factor Calculator on the Seametrics website. These numbers are based on extensive testing, which has shown close agreement among different EX sensors in the same installation. Typically, most K-factor error can be attributed to installation variables, such as depth setting and fitting configuration. Using the K-Factor Calculator: 1) Go to the Seametrics webpage, EX K-factor calculator (http://www.seametrics.com/node/223)* 2) Select your meter 3) Choose units 4) Input external pipe diameter (measure) and wall thickness (measure, or look-up in Table 2 on page 5 of this manual) FLOW RATES (IN GALLONS PER MINUTE) Feet Per Second 5) Press Calculate to determine your K-factor (NOTE: Dimension D is also calculated.) 6) Enter your K-factor into your controller *For pipe sizes larger than 50, please consult factory. NOMINAL PIPE SIZE 3 4 6 8 10 12 14 16 18 20 24 30 36 48 Min 0.28 Max 20.0 6 11 25 44 69 99 134 175 222 274 395 617 888 1580 440 783 1,762 3,133 4,895 7,050 9,596 12,533 15,863 19,584 28,200 44,064 63,452 112,804 Page 12

TROUBLESHOOTING Problem Probable Cause Try... No pulse output Unit not grounded Connect to earth ground Below minimum flow cutoff Flow reversed Output connections reversed Pipe not full Excessive electrical noise No power reversed Fluid conductivity <20 microsiemens/cm Check the Presence of Flow LED (see p. 12) Note flow direction arrow, reverse direction to meter Change output connections Check plumbing Check for proper electrical wiring Check for power across power input terminals Reverse connections Select another flow meter Output pulses incorrect Jumpy reading Missing or incorrect ground wire Incorrect depth setting Fluid conductivity <20 microsiemens/cm Empty pipe Not enough straight pipe Excessive electrical noise Rapidly changing conductivity (in chemical injection or fertigation applications) Check for proper ground Check depth setting from Dimension C table (page 4) Select another flow meter Check for full pipe or install meter in the vertical position Check for air pockets or turbulence. Refer to installation, page 6 Check for proper electrical wiring Install chemical injection line downstream of magmeter (or far enough upstream to allow complete mixing of fluids before meter) Page 13

Seametrics Incorporated 19026 72nd Avenue South Kent, Washington 98032 USA (P) 253.872.0284 (F) 253.872.0285 1.800.975.8153 www.seametrics.com LT-65200196-120913 12/9/2013