INSTALLATION AND COMMISSIONING MANUAL CONTENTS. Function. Important Product range Technical specifications

Similar documents
INSTALLATION AND COMMISSIONING MANUAL CONTENTS. Function. Product range. Technical specifications. Characteristic components

CALEFFI. Solar pump stations 01166/14 NA. 278 and 279 series 01264/16 NA

COMPONENTS FOR SOLAR THERMAL SYSTEMS

COMPONENTS FOR SOLAR THERMAL SYSTEMS

CALEFFI. Direct supply unit for heating systems. 165 series 01237/17 GB. replaces dp 01237/15 GB. Function

CALEFFI. Pre-assembled distribution manifolds for radiant panel systems. series 663 & /05 NA. Function

CALEFFI. Modulating temperature regulating unit with distribution kit for primary circuit. 171 series 01153/15 GB. replaces 01153/07 GB

CALEFFI. Motorised temperature regulating unit for heating and air conditioning systems WYP UPM series 01254/17 GB

CALEFFI. Ball shut-off valve fitted for integrated flow rate measuring sensor. 111 series 01234/13 GB. (kpa) (mm w.g.) G (m 3 /h)

CALEFFI. Composite manifolds specifically designed for radiant panel systems. 670 series 01126/18 GB. replaces dp 01126/11 GB.

CALEFFI. Distribution manifold for radiant panel systems. 664 series 01260/14 GB

CALEFFI. Distribution manifold for radiant panel systems. 664 series 01260/18 GB. replaces 01260/14 GB

CALEFFI. QuickSetter Balancing Valve with flow meter. Installation Tip

ACCREDITED. brass EN CW617N brass EN CW614N brass EN CW614N, chrome plated PTFE PSU EPDM

CALEFFI. Pre-assembled distribution manifolds for. heating and air-conditioning systems. 663 series 01065/18 GB. replaces dp 01065/06 GB.

CALEFFI. Manifolds in composite specifically designed for radiant panel systems. 670 series 01126/05 GB. Function

Pre-assembled distribution manifolds for radiant panel systems

CALEFFI. Pre-assembled distribution manifold for radiant panel systems S1 series 01144/11 GB. Replaces 01144/07 GB.

132 Series. QuickSetter Balancing Valve with flow meter NA Function

CALEFFI. HydroMixer motorized temperature mixing unit. 167 series 01239/13 NA. Function

Solar Thermal. Grant Solar Pump Station Installation & Servicing Instructions

OPERATION AND INSTALLATION

MVD, MV, MKV, MKL, 2161C, MXV Series

SINGLE MANIFOLDS TECHNICAL DATA SHEET10/ ENG

CALEFFI. Motorised ball zone valves with 3-contact control BY series 01131/18 GB. replaces 01131/11 GB

548 hydraulic separator

M-8100EP. Installation Guide ENGINEERED PLASTIC MANIFOLD SERIES. Introduction. A. Assemble Manifold Components

Connection and regulation kit for HVAC terminal units

Product Information. Brass Manifolds. Version A

Installation, commissioning and servicing instructions

VE-S_15-32 Pressure Independent Balancing & Control Valves

Manifold Isolation Valves

Installation instruction

CALEFFI. Mixing valves and actuators series 01169/17 GB. replaces dp 01169/09. Function

M Installation Guide. PRECISION Manifold Series. Introduction. A. Assemble Manifold Components

LK Manifold RF. Design. Requirements. Documentation

LK Manifold Shunt VS2

DISTRIBUTION GROUP WITH THERMOSTATIC REGULATION. Upper connections G1 F Without fittings Fittings with running connection* Without pump

INSTALLATION AND COMMISSIONING MANUAL CONTENTS. Operating principle Application diagram. Regulator-actuator Wiring diagrams

VA-8020 Floating Valve Actuator

PRESSURE CONTROL VALVES SABS 198

Valves for building. Y-strainers... page 204 PVC valves Ball valves... page 204 Butterfly valve... page 204 Ball check valve...

CALEFFI. Pressure independent control valve (PICV) 145 series 01262/14 GB B 51

VG6000 Series Forged Brass Valves

THERMOSETTER Recirculation thermal balancing valve

Valves for building. Y-strainers... page 272 PVC valves Ball valves... page 272 Butterfly valves... page 272 Ball check valves...

MUELLER GAS. Shur StopTM Unit 812 PE Line Stopping. System 8" 12" SDR Reliable Connections. General Information 2

MrPEX 1 ¼ Stainless Steel Manifold. Installation Guide

SDHW System Inspection Form

Zone Valves and Parts (Honeywell)

RESOL SBS 1000 * * Connection Operation

underfloor heating PRODUCTS FOR UNDERFLOOR HEATING

TK-6024, TK-6124, TK-8024, TK-8124

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation. 2/2-way solenoid valve 2/2-Wege-Magnetventil Électrovanne 2/2 voies

CALEFFI. FLOWCAL Automatic flow balancing valve with polymer cartridge. 121 series 01141/11 NA. Function

MF4E MF4E

For our present, For their future. Version 11.03

MrPEX 1 ½ " Brass Manifold Installation Guide

PRE-ASSEMBLED MANIFOLD KIT 1 TECHNICAL DATA SHEET 09/ ENG

VICTRIX PRO Wall-hung modular condensing boiler for heating only

CALEFFI. Motorised ball valve for central heating systems. 638 series 01196/18 GB. replaces dp 01196/12 GB

Product range Solex Technical data and dimensioning. 5 Years

GRUNDFOS DATA BOOKLET. Grundfos UPBasic. Circulator pumps 50 Hz

Components for central heating

CALEFFI. HydroMixer direct distribution unit for heating systems. 165 series 01237/13 NA. Function

AV-8020 Series Floating Control Actuated Valve

Composite PEX-AL-PEX Tubing

SE M.C.N.51D

Products for underfloor heating

KS Pump Stations. Engineering Submittal Sheet. Installation Sets for Collectors

Technote. Frese OPTIMA - Pressure independent control & balancing valve. Application. Features. Benefits.

LK Manifold RF. Design. Requirements

Revision THERMO TECHNOLOGIES. USDT 2001 Differential Controller. Installation and User s Guide

HERZ PUMPFIX HERZ PUMPFIX. Datasheet 1 45XX XX, Issue Table of contents. Page 1. General information about HERZ PUMPFIX pump groups...

NETSIAN TECHNOLOGY VALVE SCHEDULE

Flow controller with integrated control valve (PN 16) AHQM return and flow mounting

CT3202.0_01 EN February 2018

Secondary Coolant 301

DS Series Solar System

Pressure Independent Control Valve

CALEFFI. Hydraulic separator-manifold SEPCOLL. 559 series 01084/16 GB. replaces dp 01084/13 GB

Product and installation manual. Underfloor Heating Composite Manifold

Mounting and Operating Instructions EB 5863 EN. Electric Control Valves. Pneumatic Control Valve

ASSEMBLY INSTRUCTIONS FOR 30L & 50L JACKETED PROCESS REACTOR SYSTEMS

Terminator PICV. Technical Manual

SOLAR HEATING SYSTEM

M x Series Valve Linkage Kits

CIRCO5SolarCirculationUnit

VA9208-Bxx-x Series On/Off Electric Spring Return Valve Actuators

VPI45.. VPI45..Q. Combi valves, PN 25. Building Technologies. VPI45..Q with pressure test points ACVATIX

Technote. Frese OPTIMA Compact DN10-DN50 - pressure independent balancing & control valve. Application. Features. Benefits.

SBS Manual for the specialised craftsman. Filling and flushing station. Connection Operation. en Manual

PRE-ASSEMBLED MANIFOLD KIT 1 TECHNICAL DATA SHEET 10/ ENG

FO-BV Series. Fixed-orifice balancing and control valves. Technical Data Sheet. WattsIndustries.com

Pump Stations for Heating Circuits

VA-7450 Series. Electric Valve Actuators

Series description: Wilo-Stratos ECO-STG

M9106-AGx-2N0x Series Electric Non-spring Return Actuators

Selection Guide. Vx-2x13-5xx-9-xx Series Vx-2x13-8xx-9-xx Series VB-2x xx Series. Schneider Electric Ball Valve Assemblies

Mounting and Operating Instructions EB 8135/8136 EN. Series V2001 Valves Type 3535 Three-way Valve for Heat Transfer Oil

Transcription:

28237 www.caleffi.com Circulation units for solar thermal systems Copyright 204 Caleffi 278-279 series INSTALLATION AND COMMISSIONING MANUAL CONTENTS Function Important Product range Technical specifications 2 Head available at the circulation unit connections 3 Characteristic components DeltaSol C+ digital regulator 4 Installation Filling the system 5 Function Circulation units are used on the primary circuit of solar thermal systems to control the temperature in the hot water storage. The pump inside the units is activated by the signal arriving from the regulator. The units contain the functional and safety devices for optimum circuit control. They are available with flow and return connection or with return connection only. The return connection is available in versions with or without fitting for connection to the digital regulator. The DeltaSol C+ digital regulator (optional) is suitable for management and control of 9 different types of solar thermal system also in a version with an insulating casing and protective panel (code 27800). Flushing the system Commissioning Draining the system Shut-off and check valves Air separator device Flow meter Correction for different density liquids Complete closing and opening of the valve Application diagrams 8 6 7

IMPORTANT The following instructions must be read and understood before installing, commissioning and servicing the circulation unit. The safety symbol is used in this manual to draw attention to safety instructions. The meaning of this symbol is as follows: CAUTION! YOUR SAFETY IS INVOLVED. FAILURE IN FOLLOWING THESE INSTRUCTIONS MAY RESULT IN INJURY. - The circulation unit for solar thermal systems must be installed by a qualified technician in compliance with relevant national and/or local regulations. - If the circulation unit is not installed, commissioned and serviced correctly in accordance with the instructions given in this manual, it could malfunction and endanger the user. - Make sure that all connection fittings are watertight. - When making the hydraulic connections ensure that threads are not mechanically overstressed. Over time, excessive stress may cause breakages with water leaks and damage to property and/or injury of persons. - Water temperatures higher than 50 C may cause serious scalding. - During installation, commissioning and servicing take the necessary precautions to prevent injury to persons caused by high temperatures. CAUTION: Risk of electric shock. Cut off the electric supply before carrying out any work. Failure in following these instructions may result in injury of persons or damage to property. Product range Code 2780. 0 Circulation unit with return connection without digital regulator 3 l/min Code 2780. 2 Circulation unit with return connection without digital regulator 8 30 l/min sizes 3/4 and Ø 22 mm sizes 3/4 and Ø 22 mm Code 278750 Circulation unit with return connection fitted for connection to DeltaSol C+ digital regulator 3 l/min size 3/4 Code 278752 Circulation unit with return connection fitted for connection to DeltaSol C+ digital regulator 8 30 l/min size 3/4 Code 2790.0 Circulation unit with flow and return connection fitted for connection to DeltaSol C+ digital regulator 3 l/min sizes 3/4 and Ø 22 m Code 2790. 2 Circulation unit with flow and return connection fitted for connection to DeltaSol C+ digital regulator 8 30 l/min sizes 3/4 and Ø 22 mm Technical specification Materials Shut-off valve Body: Check valve: Temperature gauge: brass EN 265 CW67 brass EN 264 CW64 steel/aluminiu Flow meter Body: Transparent level gauge: Flow indicator: Hydraulic seals: brass EN 265 CW67N PS brass EN 264 CW64 EPD Deaerator Body: Instrument holder manifold Body: Sealing gaskets: O-Ring seal elements: brass EN 265 CW67 brass EN 265 CW67N EPD EPDM Insulation Material: PP Average thickness: 20 m Density: 45 kg/m 3 Working temperature range: -5 20 Thermal conductivity: 0,037 W/(m K) at 0 Reaction to fire (UL94): class HBF 2

Performance Medium: water, glycol solution Max. percentage of glycol: 50% Maximum working temperature: deaerator side flow: 60 C pump side return: 0 C Max. working pressure: 0 bar Safety relief valve working temperature range: -30 60 C Safety relief valve setting: 6 bar (for other settings refer to 253 series using adapter code F2224) Check valve min. opening pressure (Δp): 2 kpa (200 mm w.g.) Shut-off and check valves working temperature range: -30 60 C Flow meter working temperature range: -0 0 C Flow rate adjustment range: 3 l/min and: 8 30 l/min Flow rate indicator accuracy: ±0% Pressure gauge scale: 0 0 bar Temperature gauge scale: 0 60 C Connections: 3/4 F Hose connection: 3/4 M Fill/drain connections: with hose connection Ø 5 mm without hose connection Ø 3/4 garden hose Pump model Solar 5-65 (5-80 for 8 30 l/min flow meters) Body: cast iron GG 5/20 Electric supply: 230 V - 50 Hz Max. pressure: 0 bar Max. temperature: 0 C Protection class: IP 42 Digital regulator (code 27800) Electric supply: 230 V - 50 Hz Nominal power consumption:,5 VA (2 V (ac)) 4 Pt000 probe input 2 semiconductor relay outputs with contact rating: A 2 temperature probes with working range: -50 200 C Probe cable working temperature range: -50 70 C temperature probe with working range: -50 200 C Probe cable working temperature range: -50 80 C Ambient temperature range: 0 40 C Protection class: IP 20 Dimensions: 72 x x 49 mm Head available at the circulation unit connections 278 series Flow rate adjustment range 3 l/min 278 series Flow rate adjustment range 8 30 l/min 279 series Flow rate adjustment range 3 l/min 279 series Flow rate adjustment range 8 30 l/min Power consumption Power consumption 3

Characteristic components ) Grundfos Solar 5-65 or 5-80 circulation pump 2) Safety relief valve with adjustable outlet type 253 series 3) Fill/drain cock with control level 4) Instrument holder fitting with pressure gauge 5) Flow mete 6) Deaerator with air vent and shut-off valve with check valve 7) Flow temperature gauge 8) Return temperature gauge 9) Pre-formed shell insulation 0) Shut-off ball valve with check valve with temperature gauge holder knob ) Connection kit for expansion vessel (optional) 2) Display with synoptic panel and temperature readings 3) Adjustment button 4) Temperature probe 5) Stainless steel probe pocket code 257004 (optional) 6) Hose connection 7) Insulating casing with protective panel and regulator code 27800 8) Mounting bracket DeltaSol C+ digital regulator Electric supply: 230 V (ac). Complete with pre-formed shell insulation, compatible for connection to series 278 and 279 circulation units. Complete with 3 Pt000 probes; optional fourth probe. Functions: differential temperature regulator with supple mentary and optional functions. Inputs: for 4 Pt000 temperature probes. Outputs: 2 semiconductor relays. 4

Filling the syste Open the shut-off valve coupled with the automatic air vent, installed at the highest point of the solar thermal system. Open the shut-off and check valves, turning the control stems through 45 (do not remove the temperature gauges). Fill by means of a pump, using the cock (A) located at the lowest point of the system, until air no longer comes out of the air vents. If the solar thermal system requires the use of water premixed with anti-freeze, any top-ups must be carried out using a mixture with the same proportions. Close the air vent shut-off valve. Close the cock (A). Installatio Remove temperature gauge holder knob. Remove insulating shell. Slide clip to release bracket, then reposition. Fix the bracket to the wall using the fixing screws supplied in the pack (). Insert the unit from the front, fitting the pins in their seats as shown in the figure. The components are fastened to the bracket automatically by the clip (2). Establish the position for installing the expansion vessel at a distance allowed by the length of the hose, using the bracket provided. The bracket allows the use of expansion vessels with a maximum capacity of 24 l, see the instructions concerning the accessories (3). Lay the pipes of the whole system and connect the solar unit. Secure the components and the pipes to the rear insulation. Fully tighten all the fittings. The unit s threaded fittings are tightened and tested in the assembly phase in the factory. However, during commissioning the water-tightness of the fittings must be checked by means of a pressure test. Make the electrical connections of the system, as specified in the regulator instruction manual. Apply the front part of the insulation. 2 3 5

Flushing the syste Close the flow meter adjustment ball valve (). Now open the fill/drain cock (2). By means of an external (separate) pump applied on the safety unit fill/drain cock (3), allow the medium to flow through the solar panels and the heat exchange circuit until it flows out of the flow meter fill/drain cock (4). Briefly open the flow meter ball valve (4) to expel all air from the system. Leave the external pump running on the system for a few minutes to ensure correct flushing. 2 3 4 Commissionin Close the flow meter fill/drain cock () and increase pressure in the system to the maximum design pressure using the external filling pump applied to the safety unit fill/drain cock. When this pressure is reached (2), close the safety unit fill/drain cock using the control lever. Open the valves of the unit (3) and switch on the solar circulation unit pump (do not remove the temperature gauges). Allow the water to circulate for a while and then check water-tightness. Re-open the air vent installed at the highest point of the solar thermal system and repeat the deaeration procedure, briefly activating the circulation pump. Restore the desired working pressure with the filling pump. The flow rate of the system can be varied using the flow meter (4). This modulation is performed by the ball valve with which it is equipped (see respective characteristics). To regulate/limit the flow rate it is recommended to follow the indications of the solar panel manufacturer. After the first few operating hours, the solar thermal system must be deaerated again, both in the highest point and on the air separator (on versions where fitted). Once deaeration is terminated, check system pressure and if necessary restore to the desired working pressure. 2 3 4 Draining the system The draining operation is necessary if the system has been filled with water only and there is a risk of frost. Open the shut-off and check valves, turning the control knobs through 45. Open the air vents at the highest point. Open the drain cock at the lowest point of the system. 6

Shut-off and check valves The shut-off valves are equipped with a built-in check valve, positioned inside the ball.. To allow the passage of the medium in both directions, the ball valves must be opened to 45 using a 9 mm hex wrench. The check valve is opened by the ball, see figure (A). 2. In normal system operation, the ball valves must be fully open. A Flow meter The flow rate meter is a flow rate measuring device with float equipped with an adjustment ball valve. The meter has a range of 3 l/min or 8 30 l/min The flow meter must always be installed in a vertical position. Captive nut Flow rate adjustment /2 F fittin Thermometric label Graduation 3/4 F fitting A thermometric label on the back of the flow meter signals if the maximum permitted temperature (0 C) has been exceeded: white = temperature not exceeded; dark = maximum temperature exceeded. The appliance warranty will no longer apply if this label is removed. Correct position Incorrect position The reading is taken from the top edge of the float Important! Use only a 9mm hex wrench to adjust the flow meter. Air separator device The solar circulation units with flow and return connection are equipped with an air separator on the flow line. The gases separated from the thermal carrier medium collect at the top of the deaerator. The collected gases must be evacuated from time to time (every day after putting into operation and afterwards, depending on the quantity of air, once a week or once a month) by opening the manual air vent with a suitably sized screwdriver. To maintain optimal efficiency of the solar thermal system, afterwards, it is necessary to discharge air from the system every six months using the deaerator. Correction for different density liquids Changes in flow rate readings remain within the indicated accuracy (±0%) for glycol percentages of up to 50%. Complete closing and opening of the valve The valve can be fully closed or fully open. A slot on the obturator stem indicates the status of the valve. Fully closed A Fully open B 7

Application diagrams 8