Liquid Chromatography

Similar documents
S 1125 HPLC Pump System

HPLC System S 600 Series

HPLC SYSTEM S 500 SERIES

NEW HPLC - SYSTEM LINE

C196-E081C. Ultra High Performance Liquid Chromatograph Nexera X2. Specifications

PATROL UPLC Process Analysis System for Production

ACQUITY UPLC I-Class System with 2D Technology

VERITY Purification Systems Build the perfect system to fit your research

economics and performance Spark Holland introduces OPTIMAS The optimum balance of BETTER SAMPLE CARE

Spark Holland introduces ALIAS for ÄKTA pure All-round, state-of-the-art

High Pressure Valves. MX Series II Modules Manual Sample Injection Switching

Alliance HPLC DEFINED BY DEPENDABILITY, TODAY AND IN THE FUTURE

PrimeLine TM HPLC Pumps

The Agilent 1200 Series high perfor- mance autosampler SL: Area precision, injection volume linearity, minimum accessible volume, carry-over

HyperShear TM HPLC Mixers

HPLC Model 210D. UV detector lamp switch. Rheodyne 7725i injection valve. Prime/purge valve. Column. compartment. thumbscrews. Storage.

Technical Overview. Introduction

ACQUITY UPLC I-Class System Specifications

Chromatography. Liquid. HPLC Accessories SupelPRO Valves SUPELCO

QuickSplit TM Flow Splitters

High Pressure Gradient System. User Manual. Version 1.0 ( )

The Only No Compromise

High-throughput protein aggregate analysis of monoclonal antibodies using a novel dual-channel UHPLC instrument

Agilent InfinityLab LC Purification Solutions SELECTION GUIDE

HIGH PRESSURE SWITCHING VALVES

HyperShear TM HPLC and UHPLC Mixers

Agilent 1290 Infinity Autosampler

TECHNICAL REPORT. Introduction. Agilent 1100 HPLC system. Figure 1: HALO columns exhibit UHPLC-like performance at conventional HPLC pressure

HyperShear TM HPLC Mixers

Gilson, Inc. Table of Contents. Solid Phase Extraction Systems HPLC: Systems 2 9. Liquid Handlers HPLC: Liquid Handlers/Injectors 10 14

HyperShear TM HPLC and UHPLC Mixers

Fixed Flow Splitter *

Thermo Scientific Dionex UltiMate 3000 Thermostatted Column Compartment

Agilent 218 Purification Solution

Agilent 7693A Automated Liquid Sampler

Please exercise care when using solvents close to the instrument. It could damage the vapor sensor present in the ELSD.

Gilson, Inc. Table of Contents. HPLC: Liquid Handlers/Injectors GX-271 Analytical Liquid Handler...43 ISO 9001 certified.

seal, needle seat, needle assembly, seat cap kit Includes: rotor seal, needle assembly, needle seat 1100 G kit 25271

PRODUCT SPECIFICATION. Product Specification Crystal 9000 Gas Chromatograph. Chromatec Crystal Laboratory Gas Chromatography System

Impurity Testing of Fixed-Dose Combination Drugs Using the Agilent 1290 Infinity II HDR-DAD Impurity Analyzer Solution

Agilent SD-1 Purification System ml/min

78 동방하이테크상사 T.(02) F.(02)

Agilent 6850 Series II Network GC System G2630A Performance Specifications

SPECIFICATION. Bench top triple quadrupole Mass Spectrometry System coupled to a gas performance Chromatography (GC-MS/MS)

Agilent 7693A Automated Liquid Sampler

Welcome to KNAUER. Welcome to KNAUER - manufacturer of liquid chromatography instruments and solutions! Quality and environmental management

889 IC Sample Center

Application Note. Authors. Abstract. Energy & Chemicals

Liquid Chromatography LC Consumables SSI-LC

850 Professional IC. AnCat MCS Manual EN

High Sensitivity UHPLC-DAD Analysis of Azo Dyes using the Agilent 1290 Infinity LC System and the 60 mm Max-Light High Sensitivity Flow Cell

Application Note. Author. Abstract. Energy & Chemicals - Petrochemicals. Edgar Naegele, Agilent Technologies, Inc. Waldbronn, Germany

Stabinger Viscometer Series. SVM Series

Determination of fuel system icing inhibitor content of aviation turbine kerosine by HPLC

Agilent 1260 Infinity Analytical SFC System

Hitachi High-Speed Amino Acid Analyzer

Boosting Trace Detection Performance with the Vanquish Diode Array Detector and High-Sensitivity LightPipe Flow Cell

Instrumentation of HPLC. HPLC Solvent Pumping Systems

Stabinger Viscometer SVM 3001

[ APPLICATION NOTE ] INTRODUCTION APPLICATION BENEFITS WATERS SOLUTIONS KEYWORDS

Determination of Sudan Dyes I IV in Curry Paste

Agilent 1200 Series Valves

Stability Axial Compression Technology Application Ordering Information

Teledyne Isco D-Series Syringe Pumps

Chrom Tech your chromatography specialists. IDEX Injection Valves Manual. IDEX Injection Valves Actuated. 1/4-28 Flat-Bottom Injection Port Adapter

Agilent 1200 Series High Performance Autosamplers & Micro Well Plate Autosampler

MB3000. Versatile FT-IR analyzer designed for your industry The most reliable FT-IR, the lowest cost of ownership.

Model 8610C Gas Chromatograph. GC Chassis Types ECD PID FID / DELCD FPD. Mounts up to Six Detectors and Five Injectors

Using a New Gas Phase Micro-Fluidic Deans Switch for the 2-D GC Analysis of Trace Methanol in Crude Oil by ASTM Method D7059 Application

ÄKTA system Training Guide

Maintaining Your Agilent 1100 Series HPLC System

Agilent 1290 Infinity Quaternary Pump

High pressure dosing pumps Made in Germany

ÄKTA avant 150. Product Documentation

Setting up SilFlow for BackFlush in your GC

Agilent 1100 Series Capillary LC System. System Manual

Agilent 1260 Infinity Bio-inert High Performance Autosampler

Increased sensitivity and reproducibility in the analysis of trace fatty acid methyl esters in jet fuel

Mobile Phase Accessories

TSHR 6000 series TN/TS/TX analyzer

Excellence in gas analyzers since Over 180 years of JY optical experience. The expertise of Horiba combustion technology

Physiological Calibration Standard II Calibration standard physiological fluid CALIBRATION STANDARD PROTEIN

Agilent InfinityLab Quick Change Valve G4237A

System Manual. Agilent 1260 Infinity Capillary LC System

VALVES NEW MANUAL INJECTOR RHEBUILD KITS SAMPLE LOOPS MICRO VALVES PAGE 132 PAGE 136 PAGE 139 PAGE

98 동방하이테크상사 T.(02) F.(02)

P680 HPLC Pumps. Operating Instructions. Revision: 2.0 Date: April Dionex. Doc.: P680_OI_E_V2_0.doc

better analysis counts

GlycoChrom TM HPLC Analyzer. Hardware Installation and System Test

Agilent G5632 Valve Kit Instructions

DMT PERFORMING UNDER PRESSURE DMT. Pressure Scanner Features. Applications. Description 1/7

Application Note. General Use Inlet Solvent Filters. Inlet Solvent Filters. Filters and Degassers. New!

Adjustable Flow Splitter *

845Z Injection Module User s Guide

Precise metering results!

SELERITY TECHNOLOGIES SOLUTIONS FOR YOUR SUPERCRITICAL FLUID NEEDS

Agilent 1290 Infinity Quaternary Pump

HotDog HPLC Column Oven Satellite Increasing performance

Agilent 1290 Infinity II Ultra Low Dispersion Kit

Agilent Capillary Electrophoresis System. User s Guide

Transcription:

SCINTOMICS Liquid Chromatography Always the right system for your needs.

SCINTOMICS: Always the right system for your needs Advanced Research Daily QC Routine and beyond High Performance analytical/semi-preparative Radio-HPLC that covers all needs of modern radiopharmaceutical research and quality control. Data Acquisition and management with Clarity software package. Exceptional cost/performance ratio. Many options and features serve all your needs. High Performance analytical Radio-HPLC that makes your daily QC routine as simple as a click. With Azura Mobile Control SW the intuitive user interface that runs on mobile devices. Your daily routine always just a click away, always ready, always right. Expandable with options (e.g. auto sampler). 2

High-end performance and powerful features in combination with an exceptional cost/performance ratio. Encapsulated optics design to protect the optical components from fine dust or harmful gases, providing high detection sensitivity and a very stable baseline. Seya-Namioka Monochromator and a new blazed Holographic Concave Grating enhance light intensity, ensuring high sensitivity over the entire wavelength range. Automatic seal rinsing for improved longevity. Automatic compressibility compensation ensures highly precise flow rates. Optional vacuum degasser for complete removal of dissolved gases and air bubbles. Column compartment with Peltier elements for accurate temperature control (4 C up to 90 C) and high retention time reproducibility. Integrated tray to safely house solvent bottles. 3

SCINTOMICS HPLC: Pumps SCI8112 Isocratic Pump Operating principle: parallel dual-plunger pump No mixing valve Easily upgraded to SCI8110 Quaternary pump SCI8110 Quaternary Pump Operating principle: parallel dual-plunger pump Low-pressure gradient Number of solvents: up to 4 solvents Gradient formation: 4-channel mixing valve Composition precision: < 0.1 % Composition accuracy: < 0.5 % General Pump Specifications Automatic compressibility compensation Flow range: Analytical: 0.001-10 ml/min Semi-prep: 0.01-50 ml/min Flow rate accuracy: ± 1 % at 1 ml/min Flow rate precision: 0.1 % RSD at 1 ml/min Maximum pressure Analytical Cell 6000 psi / 410 bar: 0-5 ml/min 3000 psi / 205 bar: 5-10ml/min Semi-prep. Cell 3500 psi / 240 bar: 0-35ml/min 2500 psi / 170 bar: 35-50ml/min SCI8111 Binary Pump Operating principle: parallel dual-plunger pump High-pressure gradient Number of solvents: 2 Semi-automatic prime/purge Leak detection Diagnostics Error detection 4

SCINTOMICS HPLC: Detectors SCI8160 PDA Detector Slit bandwidth: 1.7 nm No. of PDA channels: 1024 Pixel resolution: 0.9 nm Wavelength: 190-950 nm Analytical Cell Path-length: 3 mm Pressure : < 1,500 psi Volume : 5 µl Semi-prep. Cell Path-length: 10 mm Pressure : < 1,500 psi Volume : 13 µl Noise level: < ± 2 10-5 AU (empty cell, 1 sec rise time, 254 nm) Drift: < 2 10-4 AU/hr (baseline correction), 0.001AU/hr (room temp) Wavelength accuracy: < 1 nm ( HY-1 Holmium Oxide filter) GLP compliance: photometric accuracy, linearity, noise nevel, drift System check SCI8120 UV/Vis Detector Wavelength range: 190-900 nm Data collection rate: up to 50Hz Light source: Deuterium & Tungsten lamp Noise level: < ±0.35 10-5 AU, 254 nm, dry cell Drift: < 1 10-4 AU/hr Bandwidth: 5 nm Wavelength accuracy: ±1 nm Wavelength precision: ±0.1 nm Linearity: >99.5 % for 2.5 AU (acetone, 254 nm) Path length: 10 mm (analytical cell) 3 mm (semi-prep cell) Cell volume: 10 µl (analytical cell) 5 µl (semi-prep cell) RI range: 1.00 1.75 RIU Noise: 5 10-9 RIU (analytical) 10 10-8 RIU (semi-prep) Flow cell vol: 7 µl (analytical), 9 µl (semi-prep) Cell pressure: 6 kg/cm 2 (5.8 bar, 84 psi) RS232 control 5

SCINTOMICS HPLC: Options SCI8101 Vacuum Degasser Number of channel: 4 channels Maximum flow rate: 10 ml/min per channel > 0 2.0 ml/ min per channel for removal of 70 % gas from Methanol Internal volume per channel : 925 µl per channel Materials in contact with solvent: Teflon and PEEK Electrochemical Detector (ECD) ECD is a detector for HPLC applied to variable analyses such as biogenic amines, phenols, vitamins, DNA adducts, inorganic ions and amino acids. Fluorescence Detector (FLD) SCI8131 Column Compartment Temperature range: 4 C (cooling) - 90 C Temperature stability: ±0.05 C Temperature accuracy: ±0.5 C Temperature programs: 40 Steps Column capacity: Analytical: max. 3 of 30 cm column (max. OD 18 mm) Semi-prep: max. 2 of 30 cm column Heat-up time: 16 minutes from 4 C to 80 C Cool-down time: 13 minutes from 80 C to 4 C Column switching: max. two automatic 6-port valve (optional) FLD is a highly sensitive, scanning fluorescence detector for liquid chromatography. It provides exceptional optical performance and operational flexibility for routine and trace analysis. 6

SCINTOMICS HPLC: System Manual Injector Rheodyne 7725i / 9725i Industry standard manual injector Analytical: 7725i (SUS) and 9725i (PEEK) Semi-prep: 3725i Column Switching Valves MX Series II (Stand-alone) automated high-pressure fluidic valves provides productivity enhancing solutions for today s demanding analytical methods. Combine MX Series II modular valves with your current instrument to support complex fluid switching and sample injection needs. TitanHP consists of an integrated driver/actuator and a removable liquid-end (Rapid Replacement Pod ) to provide a single, flexible space saving design. DuraLife wear surfaces extends valve lifetime, which means reduced field service and more customer analysis time between replacements of the wetted surfaces SCI8150 Autosampler a high-throughput autosampler with state of the art injection technology, fast injection and wash cycles, and an optional Peltier chiller/heater for samples. Full or partial loop injection along with Pressure-Assisted-Sample-Aspiration (PASA) is possible. The highly efficient needle and internal capillary wash virtually eliminates sample carry-over. Cycle time, including wash, is less than one minute. 96 standard 2 ml vials (32 mm x 12 mm) or well plates (96 or 384 capacity, deep or shallow) can be used. Sample capacity: analytical: 2 micro well plates according to SBS standards; semi-prep: 24 vials of 10 ml (LSV) Loop volume: 1-9999 µl programmable Reproducibility: RSD 0.3 % for full loop injections RSD 0.5 % for partial loopfill injections, RSD 1.0 % for µl pickup injections Carry-over: < 0.05 % RS232 Control Cooling/Heating option: 4 C 40 C 7

a robust Radio-HPLC System for a wide range of standard applications. Controlled via Mobile Control tablet app or Clarity Chrom Software. 8

AZURA: For a wide range of standard applications. AZURA Compact HPLC system is based on the multifunctional element ASM 2.1L. This element integrates up to 3 modules in one functional and space-saving unit, e.g. A degasser for a smooth baseline, a precise isocratic pump with low pulsation, and a variable UV wavelength detector. The system is supported by the Clarity Chrom software package and can also be controlled directly via the intuitive Mobile Control. Ultimate flexibility: Choose from a variety of integratable modules: P 4.1S: Pump with pressure transducer P 2.1S: Pump without pressure transducer DG 2.1S: Degasser 2-channel or 4-channel UVD 2.1S: UV/VIS detector V 2.1S: Valve drives VICI Valco valve drives Manual injection valve 9

AZURA Mobile Control Mobile Control is an intuitive software solution, easy-to-understand and to use, even for less experienced users. Controls and monitors AZURA devices and systems and performs measurements and methods. Detector traces, auxiliary traces and method parameters can be recorded, graphically depicted, analyzed, reported and exported at the click of a button. System overview provides instant insight into device and system status and allows to adjust key parameters with a fingertip. Smart user management makes the Mobile Control TM safe; ensuring that device parameters only be changed by authorized operators. Graphical display helps to avoid problems and unexpected downtime and to plan maintenance controls. Hand-held Mobile Control TM option to check the system remotely, allowing to oversee multiple systems from the comfort of your office Regular updates enable you to take advantage of new devices, features and functions as soon as they are released. 10

COMPACT Radio-HPLC: The ideal partners for GRP-Modules Compact-HPLC devices with modern technology and impressive performance, directly controllable by Scintomics Control Center (SCC) Software and GRP User Interface. The ideal partners for GRP-Modules. UV-DETECTOR 2.1S Wavelength range: 190-500 nm Deuterium (D2) lamp with integrated GLP chip Noise: ± 2.0 10-5 AU at 254 nm Drift: 3.0 10-4 AU/h at 254 nm Linearity: > 2.0 AU at 270 nm input 100-240 V, output 24 V DC, 60 W 121 x 129 x 187 mm 3 (W x H x D), 1.5 kg Double-piston PUMP P4.1S Integrated pressure sensor 0.1-10 ml/min or 0.1-50 ml/min, ceramic/stainless steel Max. pressure: 400 bar (#1), 150 bar (#2) Flow rate accuracy: deviation ±1.0%, measured at 5-50% of flow range using ethanol/water 10:90 Precision: 0.5% RSD (1 ml/min,12 MPa), measured at 1 ml/min using ethanol/water 10:90 113 x 135 x 225 mm 3 (W x H x D), 2.4 kg Injection Valve V2.1S 6-Port/2-positions Stainless steel, Valcon E3, 1/16 capillary connection 105 x 100 x 185 mm 3 (W x H x D), 1.9 kg, both without valve External DC 24V, 60 W Degasser DG 2.1S 2 channels Gas permeation through fluoropolymer membrane, max 10 ml/min Dead volume approx. 285 µl per channel Maximum pressure stability 7 bar Wetted materials PEEK, glass-filled PTFE, Teflon AF 121 x 138 x 190 mm 3 (W x H x D), 2,3 kg, 85-265 V, 50-60 Hz, 20 W Ambient conditions temperature range: 4-40 C, 39.2-104 F Air humidity: below 90%, non-condensing 11

SCINTOMICS GmbH Global Radiopharmacy Technology Lindach 4 82256 Fürstenfeldbruck / Germany T +49 (0) 8141 150 55-0 F +49 (0) 8141 150 55-15 info@scintomics.com www.scintomics.com