Polestar Compact 250A MCB Distribution Boards

Similar documents
POWERSTAR 125 POWERSTAR 125

Solar Photo Voltaic Switchgear Solutions

Consumer unit solutions to meet the requirements of the new 17th edition amendment 3 regulations

GROUP TP&N DISTRIBUTION BOARD TYPE B. Distribution boards for modern commercial & industrial installations

DX 3 MCBs. Choice of DX 3 MCBs for capacitor banks. Technical data

NS Feeder pillar up to 3200A

DX³ 4-pole RCBO 6000 A/10 ka

MINIATURE CIRCUIT BREAKER

Miniature Circuit-Breakers (MCBs)

DX³ RCBO 4500/6 ka Phase + Neutral, neutral on left

DSE201 Compact design with enhanced protection

Circuit Breaker Selection was affected by Seventeenth Edition Amendment from the First of July 2015

1.4. Product overview Memera consumer units and devices

QUALITY ASSURANCE & DOCUMENTATION

xboard safety, reliability effectively combining and performance safety, reliability and performance in commercial and industrial applications

Phase + Neutral, neutral on right side

Miniature Circuit-Breakers (MCBs)

020: 2013 CEB SPECIFICATION MINIATURE CIRCUIT BREAKER (MCB)

Btdin-RS RCBO 2p Phase + Neutral, neutral on right

Contents. Acti 9 Isobar. A type distribution board features...page 1/2. B type distribution board features...page 1/3

LOCAL SWITCH-DISCONNECTORS STANDARD DUTY, TYPE RDMP, 20-63A, IP65, 2-8 POLES TECHNICAL DATA

Contents. Acti 9 Isobar. A type distribution board features...page 1/2. B type distribution board features...page 1/3

DNX 3 MCB 4500 A / 6 ka Phase + Neutral, neutral on left side

Low Voltage Main Distribution Board

Miniature Circuit Breaker

Relax... you re in safe hands CONSUMER UNITS / PRODUCT GUIDE.

COMPLETE SOLUTIONS FOR POWER PROTECTION

DX³ RCBO 6000A Phase + Neutral, neutral on left

EAD10H80D EAD14H80D EAD17H80D

RESIDUAL CURRENT CIRCUIT BREAKER

MINIATURE CIRCUIT BREAKERS RCBO s & DIN RAIL MOUNTED FUSE HOLDERS

A distribution board you no longer need to hide!

Phase + Neutral, neutral on left side

Residential and light commercial. invicta. panelboards

, , PREPARATION - CONNECTION. Mounting:. On symmetrical EN rail or DIN 35 rail

Domae. The right solution for distribution boards

Get smart. Reduce energy consumption

CEL Isolators Helix Cut Outs

INDIAN INSTITUTE OF TECHNOLOGY KANPUR

Equipment model: auxiliary control. Pack Cat.Nos 10/16 A V± P + T shuttered module module

RX 3 M.C.B A up to 63 A

DX³ RCBO 6000 A Phase + Neutral, neutral right side

Wall mounted switchgear

RX 3 M.C.B A up to 63 A

Intelligent Choice for Prestigious Buildings

Amount (Rs) 1.5 sq. mm ISI marked, FR

BETA Low-Voltage Circuit Protection

ATyS S - ATyS d S Remotely operated Transfer Switching Equipment from 40 to 125 A

Tender Schedule for Electrical Works at Varagani Branch. Sl. No. Particulars Quantity Unit Rate Amount

RX 3 MCB 4500 A Phase + Neutral, neutral on left side

The young energy ensures more safety

87045 LIMOGES Cedex. 2. PRODUCT RANGE (continued) 1. DESCRIPTION - USE. Breaking capacity : Symbol : Technology : 3. OVERALL DIMENSIONS

Estimate For The Electrical Works At Pittakayagulla Branch Sl.N Particulars Quantity Unit Rate Amount

NB1 Miniature Circuit Breaker

DNX 3 MCB 4500 A / 6 ka Phase + Neutral, neutral on left side

Consumer Switchboards and Circuit Protection Flexible range designed for domestic and commercial installations

DX³ RCBO 6000 / 10 ka Phase + Neutral, neutral on left

Name of work : Electrification of PG Block Second Floor in V.P.S.V Ayurveda college Kottakkal.

AN ISO 9001:2015 COMPANY

DX³ RCCBs - ID 4P up to 100 A

Btdin RCBO 6000A up to 63A (2P)

LEXIC Curv LIMOGES Cedex. Cats N (s) : /68/87/88, /48, /84/85, /76/77/95/96/97, /71/72 1.

DPX moulded case circuit breakers

(1,5 modules per pole)

013 : 2009 CEB SPECIFICATION MOULDED CASE CIRCUIT BREAKERS

Switched on street lighting

Perfection that Matters

Panelboards for the S800 high performance MCB Mirage S800

Circuit Breaker Prepared By :

DATA SHEET FOR 1 TYPE COMPARTMENTALISED / NON - COMPARTMENTALISED. ( a ) CIRCUIT BREAKER FEEDERS FULLY DRAWOUT / NON DRAWOUT

The young energy ensures more safety

ic60h (6kA) single module combined RCD/MCB units ic60h (10kA) single module combined RCD/MCB units ild residual current circuit breakers idpn N Vigi

Paramount HRC Cartridge

Tender Schedule. Sl. No. Particulars Quantity Unit Rate `

Earthing Inspection Pit

A DIVISION OF TGC INTERNATIONAL LTD HIRE EQUIPMENT CATALOGUE

MESG 12 / 17.5 / 24 / 36 KV

XL 3 -N SimPly, EfficiEnt And SAfE. 3 - PHASE distribution boards up to 250 A

Switchgear Type SIMOSEC, up to 24 kv, Air-Insulated, Extendable

PDL s DBF AND DBS SERIES DISTRIBUTION BOARDS

Residual current devices

Technical data. Miniature Circuit Breakers. System pro M. System pro M

Cat. N (s) : /65/66/83/84, /94/95/96/99, /01/02/06/07/11/12/13/14. Pollution degree : C / + 40 C. .

l Suitable for most residential, commercial and light industrial applications

TECHNICAL SPECIFICATIONS OF PCC PANEL

and other modular devices for low voltage installation

DX³ RCBO 6000A Phase + Neutral, neutral on right

R.C.B.O. SP / 1 module

Power IT Compact Secondary Substations, CSS. Low Voltage Switchboard, LVS2

Miniature circuit-breaker (MCB) SH200M Series

TX³ RCCBs 2P up to 100 A

NEW TX³ RANGE PROTECTION YOU CAN RELY ON

Selection Guide. Control Circuit and Load Protection

Sentry Technical. Miniature Circuit Breakers (MCBs) Standards and approvals. Description. Technical specification

Key features. DESIGNS: - Conservator type - Hermetically sealed

QF(13) - Series Miniature Circuit Breakers

Ready to install Distribution boards, DIN rail mounted equipment, enclosures and connection systems

NPS/003/010 - Technical Specification for 400V Assemblies (LVAC Boards) utilised in Major Substations

Range 16A to 63A. Sensitivity 30mA, 100mA, 300mA, 500mA. Execution Double Pole, Four Pole. Specification IEC / IS : 2000

Control Circuit Protection

Transcription:

Polestar Compact 50A MCB Distribution Boards

MCBS, RCBOs AND DISTRIBUTION BOARDS MCBs - 6A to 63A Type B, C and D Single, Double and Triple Pole 8mm modular width 6kA BS EN 60898 RCBOs - 6A to 50A Type C Single Pole 8mm wide 6kA BS EN 6009 System TPN Boards rated 00A SPN Boards rated 5A Paint Finish, Epoxy Powder, Light Grey RAL 703 for standard boards and shade 697 to BS38C for IP66 Custom Built Specials Service

4 POLESTAR COMPACT DISTRIBUTION BOARDS & INCOMING OPTIONS 50A TYPE B DISTRIBUTION BOARDS AND THEIR INCOMING OPTIONS l Incoming options - order separately: Integral metering available Busbars rated at 50A IP3X (Door Closed) Full compliment of Neutral & Earth terminals Incoming maximum 0mm Outgoing maximum 5mm 8PSCMR POLESTAR COMPACT INCOMER OPTIONS l 50/SDB 003MB 00/SDBDP Allows the fixture of dual Earth bars (IP3X) Clean Earth kit available (IP3X) All IP3X boards are supplied as standard with hinged outer door, catch (lock is optional extra) and removable top/bottom gland plates IP8PSCMR SWITCH DISCONNECTORS AND DIRECT CONNECTION l Switch Disconnector 50A 3P* 00A P List No 50/SDB 00/SDBDP 50mm terminal capacity * Derated to 5A when used as an incomer to MCB distribution Boards BS EN60947-3, IEC60947-3 Direct Connection 50A 3P 0mm terminal capacity 50/DCB All Incomers are supplied complete with mounting kit, links & fixing screws MOULDED CASE CIRCUIT BREAKERS l 00A 3P 00A 4P 85mm terminal capacity Neutral busbar supports incorporate an integral MCB end stop BS EN 6439-3 003MB 004MB All Incomers are supplied complete with mounting kit, links & fixing screws IEC 60947-, EN 60947-

CSBC 6CL 8PSCMBP 8PSCDIN8 8PSCAS 8PSCBB MCBLD + 748 Blanking Strip 7CC (fitted to Earth Bar) CLEB CLNB DIN RAIL, ROWBOARD, SERVICE CENTRES l Service Centre/ DIN Rail Board: List No 8 Module 8PSCDIN8 36 Module ( Rows of 8) 8PSCDIN36 Add-On for fixture to IP3X type B board. Equipped with easily removed DIN Rail to accommodate 8 or 36 8mm module wide DIN Rail mounted devices 45 & 40mm high Cable Spreader Box Add on Enclosure, 45mm high, Blank front cover plate 8PSCSB Rowboard: No of Rows H W D 45 430 55 8PSCAS 40 430 55 8PSCAS 3 570 430 55 8PSCAS3 4 735 430 55 8PSCAS4 5 85 430 55 8PSCAS5 Suitable for Stand-Alone use or Add-On to IP3X type B board. Each row will accommodate 8 off 8mm module wide DIN Rail mounted devices. Main Neutral and Earth Bars included, along with provision for additional Mini Neutral and Earth bars. GENERAL POLESTAR ACCESSORIES TP & SP l List No Cylinder Lock & Key 6CL MCB Locking device (excl. lock) MCBLD Padlock & Key for use with MCBLD 748 Clean Earth Bar Kit type B Boards only. 8CEBK (4 to way= kit, 6 to 4 way= kits). SP MCB size Blank (shields MCB & Busbar Terminal) 8PSCMBP Blanking Strip - 6 Individual module wide pieces 8PSCBP/6 Blanking Strip - 4 lengths each 3 modules wide 8PSCBP3/4 Blanking Strip - lengths each modules wide 8PSCBP/ Clip In Blank SP Moulding CSBC Busbar cross connector insulator - pack of 9 8PSCBB Cable clamp assembly (70mm ) - pack of 3 7CC ADDITIONAL EARTH BAR KITS l Additional Earth Bars to fit TP Distribution Boards No of Ways List No No of Ways List No 4 8EB04 6 8EB6 6 8EB06 0 8EB0 8 8EB08 4 8EB4 8EB Earth and Neutral bar, 0mm cable max, for use with DIN Rail NEUTRAL EARTH 7 Terminals CLNB07 CLEB07 Terminals CLNB CLEB 5 Terminals CLNB5 CLEB5 POLESTAR COMPACT 50A DISTRIBUTION BOARD ACCESSORIES 5

6 POLESTAR COMPACT MCBs & RCBOs MCBs SINGLE POLE MCBs - 6kA l RATING AMPS B TYPE C TYPE D TYPE 6A 70B/06 70C/06 70D/06 0A 70B/0 70C/0 70D/0 6A 70B/6 70C/6 70D/6 0A 70B/0 70C/0 70D/0 3A 70B/3 70C/3 70D/3 40A 70B/40 70C/40 70D/40 50A 70B/50 70C/50 70D/50 63A 70B/63 70C/63 70D/63 BS EN 60898 Type B (3 5In), C (5 0In), D (0 0In) classification Short circuit duty rating: Type B/C/D 6000A 40V/45V 50Hz Terminal capacity up to 35mm cable 8mm modular width 7B/0 7C/0 73C/0 73C/3 RCBOs DOUBLE POLE MCBs - 6kA l RATING AMPS B TYPE C TYPE D TYPE 6A 7B/06 7C/06 7D/06 0A 7B/0 7C/0 7D/0 6A 7B/6 7C/6 7D/6 0A 7B/0 7C/0 7D/0 3A 7B/3 7C/3 7D/3 40A 7B/40 7C/40 7D/40 50A 7B/50 7C/50 7D/50 63A 7B/63 7C/63 7D/63 BS EN 60898 Type B (3 5In), C (5 0In), D (0 0In) classification Short circuit duty rating: Type B/C/D 6000A 40V/45V 50Hz Terminal capacity up to 35mm cable 8mm modular width Not for use within standard type A or B distribution boards TRIPLE POLE MCBs - 6kA l RATING AMPS B TYPE C TYPE D TYPE 6A 73B/06 73C/06 73D/06 0A 73B/0 73C/0 73D/0 6A 73B/6 73C/6 73D/6 0A 73B/0 73C/0 73D/0 3A 73B/3 73C/3 73D/3 40A 73B/40 73C/40 73D/40 50A 73B/50 73C/50 73D/50 63A 73B/63 73C/63 73D/63 BS EN 60898 Type B (3 5In), C (5 0In), D (0 0In) classification Short circuit duty rating: Type B/C/D 6000A 40V/45V 50Hz Terminal capacity up to 35mm cable 8mm modular width RCBOs SINGLE MODULE - 30mA SENSITIVITY - 6kA l Single Pole Type A MCB Type C Current rating (A) List No 6A 70C/063 0A 70C/03 6A 70C/63 0A 70C/03 3A 70C/33 40A 70C/403 50A 70C/503 Standard compliance BS EN 6009; IEC 009. Short circuit duty rating 6000A 40V 50Hz. Terminal capacity up to 6mm cable. 8mm modular width

POLESTAR COMPACT SUB METERING OPTIONS SUB METERING l Sub metering provides an awareness of energy use. Trends of minimum and maximum demand become visible enabling any instances of energy waste to be identified. Metering alone cannot reduce energy consumption or subsequent carbon emissions - action taken based upon knowledge gained from an effective metering strategy can. Schedule 7 of the Electricity Act 989 requires that all meters must be approved for use in a billing situation. MID (Measuring Instruments Directive) approved meters have, since 006, been approved for billing purposes across the EU. Non MID meters include MODBUS (RTU) connections and pulsed output as a standard feature. MID meters are supplied with a pulsed output as a standard feature. LS50MPKIT LS5MPKIT 8MPSC50LP INTEGRAL METER KIT I Integral meter kits suitable for mounting within 50A type B Meter Ready (MR) Distribution Boards. Includes a Digital energy meter, three current transformers, fuses, neutral link, wiring looms and mounting base plate. Suitable for use with a 3ph 4 wire unbalanced system. Description 50A Integral Meter Kit LS50MPKIT Integral Meter Kit (MID) LS50MIDMPKIT 50A DUAL METER PACK I 740mm high add on assembly suitable for mounting directly beneath two surface 50A type B Distribution Boards. Includes two digital energy meters, six current transformers, all associated fuses & wiring and flexible interconnections to Distribution Boards. Provides single point isolation while dual meters allow for separate monitoring of Light and small Power energy consumption. Suitable for use with a 3ph 4 wire unbalanced system. Description 50A Add-on Dual Meter Pack 8MPSC50LP For use with IP3X Type B Distribution Boards. POLESTAR COMPACT METERING OPTIONS 7

POLESTAR COMPACT MINIATURE CIRCUIT BREAKER - Tripping Characteristics and Earth Loop Impendance Values l Tripping Characterteristics TRIPPING TIME MINUTES SECONDS.3.45 0 60 40 0 0 6 4 40 0 0 6 4 0.6 0.4 0. 0. 0.06 0.04 0.0 0.0.5 3 I_3653 4 5 6 8 0 5 0 30 MULTIPLE OF RATED CURRENT Maximum earth fault loop impedance (Zs) for circuit breakers with Uo of 30V, incorporating the 0.95 Cmin factor, 7th Edition IET Wiring Regulations (BS767:008), Amendment 3 effective from st January 05 Characteristic B t a 0.4s t a 5s I n (A) Ω Ω 6 7. 7. 0 4.37 4.37 6.76.76 0.9.9 3.33.33 40.05.05 50 0.86 0.86 63 0.67 0.67 Tripping characteristic B For universal use in socket outlet and lighting circuits. TECHNICAL DATA POLESTAR COMPACT 8 TRIPPING TIME MINUTES SECONDS TRIPPING TIME MINUTES SECONDS.3.45 0 60 40 0 0 6 4 40 0 0 6 4 0.6 0.4 0. 0. 0.06 0.04 0.0 0.0.3.45 0 60 40 0 0 6 4 40 0 0 6 4 0.6 0.4 0. 0. 0.06 0.04 0.0 0.0.5.5 3 3 I_365 4 5 6 8 0 5 0 30 MULTIPLE OF RATED CURRENT I_3654 4 5 6 8 0 5 0 30 MULTIPLE OF RATED CURRENT Characteristic C t a 0.4s t a 5s I n (A) Ω Ω 6 3.6 7. 0.9 4.37 6.33.66 0.05.09 3 0.67.33 40 0.57.4 50 0.48 0.95 63 0.38 0.76 Tripping characteristic C Particularly advantageous in lamp and motor circuits with higher starting currents. Characteristic D t a 0.4s t a 5s I n (A) Ω Ω 6.38 7. 0.05 4.37 6 0.67.66 0 0.48.09 3 0.9.33 40 0.7.4 50 0. 0.95 63 0.9 0.76 Tripping characteristic D For electrical circuits with strong pulse-generating equipment, such as transformers or solenoid valves.

POLESTAR COMPACT MINIATURE CIRCUIT BREAKER - Rating of Luminaire Circuits l Maximum permissible lamp load of a miniature circuit breaker when operating fluorescent lamps L 8 W, L 36 W, L 38 W, L 58 W Maximum number of fluorescent lamps Electronic ballast Full switching at 30 V Group switching at 30 V I n (A) Lamp -lamp ) -lamps ) -lamp ) -lamps ) Characteristic B C D B C D B C D B C D 6 L 8 W 7 37 66 7 35 35 66 66 66 35 35 35 L 36 W 7 37 37 7 9 9 37 37 37 9 9 9 L 58 W 7 9 9 9 9 9 0 L 8 W 36 67 36 58 58 58 58 58 L 36 W 36 6 6 3 3 3 6 6 6 3 3 3 L 58 W 3 3 3 0 0 0 3 3 3 0 0 0 6 L 8 W 56 00 77 56 94 94 77 77 77 94 94 94 L 36 W 56 00 00 5 5 5 00 00 00 5 5 5 L 58 W 5 5 5 3 3 3 5 5 5 3 3 3 0 L 8 W 70 7 70 7 7 7 7 7 L 36 W 70 7 5 64 64 64 5 5 5 64 64 64 L 58 W 64 64 64 40 40 40 64 64 64 40 40 40 3 L 8 W 00 44 355 00 44 88 355 355 355 88 88 88 L 36 W 00 44 00 00 03 03 00 00 00 03 03 03 L 58 W 00 03 03 65 65 65 03 03 03 65 65 65 40 L 8 W 6 6 444 6 6 35 444 444 444 35 35 35 L 36 W 6 6 50 6 9 9 50 50 50 9 9 9 L 58 W 6 9 9 8 8 8 9 9 9 8 8 8 50 L 8 W 80 47 555 80 47 94 555 555 555 94 94 94 L 36 W 80 47 3 6 6 6 3 3 3 6 6 6 L 58 W 6 6 6 0 0 0 6 6 6 0 0 0 63 L 8 W 70 340 567 70 340 370 700 700 700 370 370 370 L 36 W 70 340 393 70 03 03 393 393 393 03 03 03 L 58 W 70 03 03 8 8 8 03 03 03 8 8 8 ) All ECGs are turned on simultaneously. ) The ECGs are turned on in groups one after the other. Reduction factors for miniature circuit breakers for the simultaneously switcing on of incandescent lamp loads, taking into account the rated current of the miniature circuit breaker and the summated current of the lamps Reduction factor Switching with miniature circuit breaker Switching with separate switch Characteristic B 0.5 0.6 Characteristic C Characteristic D Current carrying capacity of miniature circuit breakers with corrected and uncorrected HQ, HQI and NAV lamps (number) Lamp power (W) 35 70 50 50 400 000 000 3500 Lamp current (A) 0.5.8 3 3.5 9.5 0.3 8 Corrected lamp current (A) 0.3 0.5.5 6 5.5 9.8 Inrush peak (A) 0 8 36 60 70 0 5 0 In(A) Lamp power (W) 35 70 50 50 400 000 000 3500 Characteristic B 6 0 0 0 0 0 0 0 5 3 0 0 0 0 6 8 5 0 0 0 0 6 3 0 3 6 8 4 0 40 0 5 3 3 50 8 5 7 4 4 63 6 4 7 4 3 Characteristic C 6 6 3 0 0 0 0 0 0 6 3 0 0 0 6 6 9 4 0 0 8 0 5 3 0 3 6 3 3 40 33 8 9 5 4 50 38 0 6 5 3 3 63 53 9 4 9 7 4 4 Characteristic D 6 8 4 0 0 0 0 4 7 4 0 0 0 6 6 3 3 0 0 8 4 7 4 4 0 3 44 7 6 40 56 8 5 9 8 3 50 70 35 9 0 4 3 63 88 44 4 4 4 4 Different data for corrected/uncorrected lamps. Circuit impedance: The specified lamp loads apply, taking into account a line impedance of 800 m. At 400 m the permissible values are reduced by 0%. TECHNICAL DATA POLESTAR COMPACT 9

POLESTAR COMPACT RANGE l TECHNICAL DATA POLESTAR COMPACT DISTRIBUTION BOARDS l Standards Compliance: BSEN6439-3 and IEC 6439-3 Rated Voltage: 30/400V, 50/60Hz Busbar Rating: 50A Rated Insulation Voltage: 500V a.c. Short Circuit Withstand: 5kA Conditional 7.kA for 0.5 sec..0ka for sec. Protection Degree: IP3X (Door Closed) ISOLATORS & SWITCH DISCONNECTORS l When used as an incomer to MCB Distribution Boards Standards Compliance: Rated Voltage: Rated Insulation Voltage: Rated Impulse Withstand Voltage: Rated Duty: 00A 5A Pole Configuration: Isolators 5A BSEN60947-3 and IEC/EN60947-3 30/400V, 50/60HZ 500V a.c. 6kV a.c. peak AC B (Double Pole) AC B (Triple Pole) Double Pole, Triple Pole M0 Lug (0mm wide) ISOLATORS & SWITCH DISCONNECTORS l When supplied loose Standards Compliance: BSEN60947-3 and IEC/EN60947-3 Rated Voltage: 30/400V, 50/60HZ Rated Insulation Voltage: 500V a.c. Rated Impulse Withstand Voltage: 6kV a.c. peak Rated Duty: 00A AC B (Double Pole) 50A AC B (Triple Pole) Pole Configuration: Double Pole, Triple Pole Isolators 63 to 5A: 50mm 50A Incoming - M0 Lug (0mm wide) Outgoing - M8 Lug (6mm wide) TYPE B AND ROW DISTRIBUTION BOARDS l 50A List No. H 8PSC04MR 768 8PSC06MR 8 8PSC08MR 876 8PSCMR 984 8PSC6MR 09 8PSC0MR 00 8PSC4MR 308 Add on enclosures List No. H List No. H 8PSCDIN8 45 8PSCAS 45 8PSCDIN36 40 8PSCAS 40 8PSCSB 45 8PSCAS3 570 Meter Packs 8MPSC50LP 740 8PSCAS4 735 8PSCAS5 85 Dual meter packs (LP) have a width equal to that of two distribution boards RESIDUAL CURRENT CIRCUIT BREAKERS (RCCBs) l Standards Compliance: EN6008 and IEC 6008 Rated Voltage: 30/400V, 50/60Hz RCD Class: Type AC Maximum Terminal Capacity: 35mm MINIATURE CIRCUIT BREAKERS (MCBs) l Standards Compliance: BSEN60898 and IEC 60898 Rated Voltage: 30/400V, 50/60Hz Short Circuit Capacity: 6kA BSEN60898- and IEC60898- Tripping Characteristics: Types B, C and D Temperature Range: Maximum Operating Temperature: 55 C Pole Configuration: Single Pole, Double Pole, Triple Pole Maximum Terminal Capacity: 35mm MOULDED CASE CIRCUIT BREAKERS (MCCBs) l Standards Compliance: Rated Current In: Rated Configuration: Rated Operational voltage: Rated Breaking Capacity: RCBOs l IEC/EN60947-00A 3 Pole or 4 Pole 690V 65kA Standards Compliance: EN6009, IEC 6009 Rated Voltage: 30V 50Hz Rated Short Circuit Capacity: 6kA MCB Tripping Characteristics: Type C RCD Class: Type A Neutral: Unswitched Maximum Terminal Capacity: 6mm Neutral flying lead and functional earth lead provided During interruption of the neutral conductor the protective function is guaranteed when FE & PE conductors are connected 45 430 surface Height H 55 overall 0

Acknowledged as one the leading brands in the UK and in British Standard markets around the world, Crabtree offers designers & specifiers a wide range of quality products that caters for a vast array of applications including Commerce, Offices, Education, Hospitals & Health, Hotels & Leisure facilities, in fact wherever quality products are required. Crabtree factories operate a series of internationally recognized standards including ISO900 for quality, OHSAS 800 for Health & Safety and ISO400 for Environmental Management. The UK production locations are home to the product management, engineering, design, quality & logistics teams. In the UK Crabtree operates two UKAS accredited Laboratories that carry out R&D and compliance testing on all Crabtree products, these highly accredited facilities ensure that safety, quality & reliability remain consistent with UK & EU legislation regulations & Siemens internal standards, policies and practices. Crabtree products are all designed manufactured and tested in accordance with the recognised product standards, and backed by standard & extended guarantees. Crabtree also operates to recognised standards for product safety & sustainability, Crabtree wiring accessories are ROHS and REACH compliant often in excess of the UK market standards. Crabtrees WEEE compliance process and recycling scheme ensures that the end of product life circumstances are catered for in line with UK & EU Legislation. Recycled materials are used in product packaging, and declared into a recycling scheme locally to control environmental impacts and assure that the maximum level of recycling of materials and use of recycled materials is achieved. As a Siemens company Crabtree also operates a zero harm scheme within all of its manufacturing, logistics & sales facilities, and is proud to have achieved a 5 star Health & Safety rating.

ELECTRIUM SALES LIMITED A SIEMENS COMPANY Commercial Centre, Lakeside Plaza, Walkmill Lane, Bridgtown, Cannock WS 0XE. email: info@electrium.co.uk Web: www.electrium.co.uk UK SALES Telephone: 0543 45500 Facsimile: 0543 4550 email: crabtree.sales@electrium.co.uk TECHNICAL Telephone: 0543 43830 Facsimile: 0543 4383 email: crabtree.technical@electrium.co.uk EXPORT SALES Telephone: +44 543 455049 Facsimile: +44 543 455048 email: export@electrium.co.uk DUBAI OFFICE Telephone: +97 4 3660684 Facsimile: +97 4 3660676 email: export@electrium.co.uk Although every effort has been made to ensure accuracy in the compilation of the technical detail within this publication, specifications and performance data are constantly changing. Latest details can be obtained from Crabtree. Publication No. B7 /5 Printed in England.