GENREADY LOAD CENTER AND TRANSFER SWITCH

Similar documents
Owner's Manual. GenReady Load Center and Transfer Switch. This manual should remain with the unit. Model Numbers. GenReady Basic Panelboard

Owner's Manual. GenReady Multi-breaker Load Center and Transfer Switch. or GENERAC. This manual should remain with the unit.

n Ilation instructions Load Center Transfer TMOperator

SECTION 32 - PAD-MOUNTED CAPACITORS TABLE OF CONTENTS

Owner s Manual. For Automatic Transfer Switch. 50 & 100 Amp. Model Number RTG10EZA1 RTG12EZA1 RTG16EZA1 MODEL NUMBER: SERIAL NUMBER: DATE PURCHASED:

CONTROL POWER OFF ON ALARM SILENCE / TEST NEMA 4X 304 STAINLESS STEEL ENCLOSURE W/ OUTER DOOR LAYOUT CUSTOMER JOB NAME PRODUCT O:

Owner s Manual. For Automatic Transfer Switch. PowerPact Home Standby Generator MODEL NUMBER: SERIAL NUMBER: DATE PURCHASED:

Vigilant Automatic Transfer Switches

A. Submit manufacturer's literature and technical data before starting work.

1100 OVERHEAD TRANSFORMERS

OTEC Transfer switch open transition

CON EDISON EQUIPMENT

RTS Automatic Transfer Switch TECHNICAL MANUAL. A new standard of reliability. This manual should remain with the unit.

Electrical Design/Build Guide

Owner s Manual. For Automatic Transfer Switch. 50 & 100 Amp. Model Number RTG10EZA1 RTG12EZA1 RTG16EZA1 MODEL NUMBER: SERIAL NUMBER: DATE PURCHASED:

INSTALLATION MANUAL MODEL #100947, AMP MODEL #100949, AMP RELIANCE CONTROLS ARL SERIES AUTOMATIC TRANSFER SWITCH

MCM CABLE 3/15/2010

Quick Start Guide TS 910 & TS 920

CHPC Transfer switch closed transition

Bussmann series Quik-Spec Power Module Switch elevator disconnect

ANZI Transfer Switch and Generator Wiring Installation Addendum

Owner s Manual. For Automatic Transfer Switch. 50 & 100 Amp. Model Number RTG10EZA1 RTG12EZA1 RTG16EZA1 MODEL NUMBER: SERIAL NUMBER: DATE PURCHASED:

Selection and application guide

Owner s Manual. For Automatic Transfer Switch. 100 Amp. Model Number RTG16EZA3 MODEL NUMBER: SERIAL NUMBER: DATE PURCHASED:

Quick Start Guide TS 910

Transfer switch OTEC open or delayed transition

SECTION LOW VOLTAGE DISTRIBUTION EQUIPMENT

7kW. 7kW. CorePower System Residential Standby Generators Air-Cooled Gas Engine FEATURES. Power Rating Model (Composite Polymer) - 7 kw 60Hz

Product Specification Sheet #3LD2.1

Zenith ZTX. GE Energy Digital Energy. Automatic Transfer Switch

Effective December 2015 Supersedes September 2013

STANDBY GENERATOR 100 kw LIQUID-COOLED GENERATOR SET INCLUDES FEATURES. Standby Power Rating Model HT kw 60Hz

16/20/22 kw CENTURION SERIES

STANDBY GENERATOR 130 kw LIQUID-COOLED GENERATOR SET INCLUDES FEATURES. Standby Power Rating Model HT kw 60Hz

Owner's Manual. This manual should remain with the unit.

Customer Requirements Downtown Secondary Network Service

Transfer switch OTPC open, closed, or delayed transition

A. This Section includes Low Voltage Switchgear Work, as indicated on the drawings, and as specified herein.

17 kw GENERAC GUARDIAN SERIES STANDBY GENERATORS - PREPACKAGED. Air-Cooled Gas Engine Generator Sets FEATURES

Transfer switch OHPC open or delayed transition

Installation and Construction Notes for EVSE4

GENERAC GUARDIAN SERIES STANDBY GENERATORS

*Only if located away from doors, windows and fresh air intakes, and unless otherwise directed by local codes.

INSTRUCTIONS FOR THE RELIANCE Fast/Tran TM ARL0909 & ARL0909R

MP Meter-Pak Meter Centers Product Description PRODUCT DESCRIPTION. MP Meter-Pak Meter Centers

MP Meter-Pak Meter Centers Product Description PRODUCT DESCRIPTION. MP Meter-Pak Meter Centers

Transfer switch OTEC and OTECSE open transition

STANDBY GENERATOR 80 kw LIQUID-COOLED GENERATOR SET INCLUDES FEATURES. Standby Power Rating Model HT kw 60Hz

Pow-R-Line 3E Panelboard

RTS Automatic Transfer Switch TECHNICAL MANUAL. A new standard of reliability. This manual should remain with the unit.

70 kw GENERAC STANDBY GENERATORS. Liquid-Cooled Engine Generator Sets FEATURES INCLUDES: Standby Power Rating Model QT070 (Bisque) - 70 kw 60Hz

Section 4 Square D QO Loadcentres

20 kw GENERAC GUARDIAN SERIES STANDBY GENERATORS - PREPACKAGED. Air-Cooled Gas Engine Generator Sets FEATURES

Florham Park, NJ USA Call (ASCO) for sales or service

AMENDMENT ELECTRIC SERVICE MANUAL 2014

Zenith ZBTS/ ZBTSD/ZBTSCT

INSTRUCTIONS FOR THE RELIANCE CONTROLS ARM SERIES AUTOMATIC TRANSFER SWITCH

INSTALLATION INSTRUCTIONS AND OPERATION MANUAL

M - F 8:00 AM - 5:00 PM CT

OTPC-SE Service entrance transfer switch open transition

8/10/14kW. 8/10/14kW. GUARDIAN SERIES Residential Standby Generators Air-Cooled Gas Engine FEATURES INCLUDES:

SECTION PANELBOARDS

Ge 600 Manual Transfer Switch 100 Amp Generator

SPEEDFAX TM 2011 Load Centers & Circuit Breakers Contents

16 kw CENTURION STANDBY GENERATOR. Air-Cooled Gas Engine Generator Sets FEATURES. Standby Power Rating Model (Steel - Gray) - 16 kw 60Hz

Ground Mount / Piping / Electrical Quick Reference ECS Membrane Processor: PMC and ISD

Automatic Transfer Switch

Bulletin 1494F Fixed-Depth Flange-Mounted Disconnect Switches. Selection Guide

GENERAC GUARDIAN SERIES STANDBY GENERATORS

Automatic Transfer Switch

NORTH CAROLINA SHERIFFS ASSOCIATION

SERIES TS AMP AUTOMATIC TRANSFER SWITCHES

Ge 600 Manual Transfer Switch 200 Amp Nema 3r

BTPC Bypass isolation transfer switch open or closed transition

Quik-Spec Coordination Panelboard Specifications

Owner's/Installation Manual

User s Manual. ACH550-CC/CD Packaged Drive with Classic Bypass Supplement for ACH550-UH HVAC User s Manual

Automatic Transfer Switch

Introduction. P1 Panelboards. P1 Feature Overview. Contents. Siemens Panelboards Introduction to P1 Panelboards 1. General Specifications 3

User s Manual. ACS550-CC Packaged Drive with Bypass Supplement for ACS550-01/U1 Drives User s Manual

GENERAC GUARDIAN SERIES STANDBY GENERATORS

INSTALLATION INSTRUCTIONS AND OPERATION MANUAL

User s Manual. ACH550-CC/CD Packaged Drive with Classic Bypass Supplement for ACH550-UH HVAC User s Manual

FLORIDA SHERIFFS ASSOCIATION & FLORIDA ASSOCIATION OF COUNTIES

Apollo Solar Inverter Switchgear Module Installation Manual Rev 1.2 Page 1

Quick Connection Panel (QCP) Installation Guide

RCS1000 Data Sheet. RCS1000 Series Controllable Circuit Breaker Panel

Owner s Manual. For Automatic Transfer Switch Amp, Service Entrance / Non-Service Entrance

16 kw CENTURION STANDBY GENERATOR. Air-Cooled Gas Engine Generator Sets FEATURES. INCLUDES: True Power Electrical Technology

Owner's Manual. LTS Load Shed Switch. This manual should remain with the unit.

SECTION ENCLOSED SWITCHES AND CIRCUIT BREAKERS

First Floor Plan - EPC105, 111 and 113 Remodel EL POMAR CENTER (EPC) Facilities Services. Scale: As Shown Date: 05/31/17 Drawn by: LCE

Owner's Manual. LTS Load Shed Switch. This manual should remain with the unit.

ECOVISION DOOR SYSTEM FOR

Automatic Transfer Switch

ARPF. Air Handler with Painted Cabinet. 1½ to 5 Tons Multi-Position,

Section SWITCHBOARDS. Introduction. Part 1 - General. Related Work

Cable-Operated Disconnect Switches. Accessories

Acme Conduit Entry. String Combiner/Pass-Through. FOR PHOTOVOLTAIC INSTALLATION Installation Manual

GENERAC QUIETSOURCE SERIES STANDBY GENERATORS

Transcription:

GENEADY LOAD CENTE AND TANSFE SWITCH DESCIPTION The Geneady load center is a hybrid panel that operates as a normal load center and also allows for seamless integration of standby generators. GENEADY LOAD CENTE FEATUES 4 circuit capacity with the use of tandem breakers Dimensions are the same as a standard 42-space main load center Utilizes standard Siemens components Protect up to 8 circuits, up to 3 with the use of tandem breakers circuits available for non-protected loads Circuits can easily be shifted from protected to non-protected and vice versa UL listed and service entrance rated Models available with or without EZ Transfer operator factory installed Single panels are compatible with generators rated up to Amps/3 kw Multiple Geneady load centers can be supported with a single generator Flush Mount NEMA Enclosure EZ TANSFE OPEATO FEATUES Factory installed on the Geneady Advanced model. Can be easily installed in the field on the Geneady Basic with available kit Allows for manual or automatic operation Please Note: The Geneady Panel is designed to be directly compatible with any Generac manufactured product. Use of another manufacturer s generator may require the purchase and installation of additional sensing and control components.

PODUCT OPTIONS Geneady Load Center and Transfer Switch Geneady Basic Load Center Model Number 5448 Geneady Advanced Load Center with EZ Transfer Operator Model Number 5449 EZ Transfer Operator Field Installation Kit Model Number 5447 Includes: A Circuit Breaker A Lower Panel Circuit Switch 2A Main Circuit Breaker INSTALLATION OPTIONS Includes Geneady Basic plus: EZ Transfer Operator A Lower Panel, Generator Circuit Switch 5A Double Pole Breaker for Sensing Circuit Plus all other components found in the field installation kit. Transfer Operator Field Installation Kit Includes: Transfer Operator 5A Double Pole Breaker for Generator Sensing Circuit A Lower Panel, Generator Circuit Switch Hold Down Bracket Interlock Bar Mounting Hardware Decals Installation Guide Geneady Basic Geneady Advanced Geneady Complete The Geneady load center is installed without the EZ Transfer operator. It replaces the home s main load center. This option will save the homeowner thousands in upgrade costs when a generator is installed. The Geneady load center is installed with the EZ Transfer operator. All fuel and electrical lines (contractor supplied) are installed to the planned generator site along with the generator pad (if required). The home is completely wired and ready for the addition of a generator in the future. Everything included in the Geneady Advanced level is installed along with an automatic standby generator. The home s selected circuits will be backed up by generator power whenever the utility is lost.

5A A 5A A INTECONNECTIONS Geneady Load Center and Transfer Switch GOUP GENEAC P/N G4746 FUSE W/HOLDE G858E DECAL POWE LEADS AND TANSFE SWITCH LEADS MUST BE UN IN TWO DIFFEENT CONDUITS. METE EXCEPTIONS: IF THE INSULATION ATING ON ALL WIING IS ATED FO 6V AND THE LENGTH OF THE CONDUIT IS 3ft O LESS IT IS ACCEPTABLE TO INCLUDE GENEATO CONTOL & POWE WIING IN ONE CONDUIT. SOCKET GND 5A FUSE EPLACEMENT 5A, 32VDC TYPE-ATO G N 94 WANING NOTE WIE OIENTATION 24VAC INPUT 2VDC TANSFE ELAY COIL 4 3 2 N L GENEAC NEUTAL BA GOUND BA ENGINE GENEATO CONNECTION PANEL ALL WIING TO BE MINIMUM 8AWG, 3VAC ATING. ECOMMENDED WIE TYPE: THHN LICENSED ELECTICIAN AND MUST NOTE: INSTALLATION TO BE DONE BY A MEET ALL NATIONAL, STATE AND LOCAL ELECTICAL CODES. GEN-EADY LOAD CENTE EXPLODED VIEW: GEN EADY LOAD CENTE DAWING #: G4744 EVISION: H-2827-D DATE: 9/8/8 PAGE OF 4 of 3

5A A 5A A INTECONNECTIONS Geneady Load Center and Transfer Switch GOUP G POWE LEADS AND TANSFE SWITCH LEADS MUST BE UN IN TWO DIFFEENT CONDUITS. EXCEPTIONS: IF THE INSULATION ATING ON ALL WIING IS ATED FO 6V AND THE LENGTH OF THE CONDUIT IS 3ft O LESS IT IS ACCEPTABLE TO INCLUDE GENEATO CONTOL & POWE WIING IN ONE CONDUIT. GOUDING OD (ELECTODE) N ENGINE GENEATO CONNECTION PANEL ALL WIING TO BE MINIMUM 8AWG, 3VAC ATING. ECOMMENDED WIE TYPE: THHN NOTE: INSTALLATION TO BE DONE BY A LICENSED ELECTICIAN AND MUST MEET ALL NATIONAL, STATE AND LOCAL ELECTICAL CODES. GOUNDING ELECTODE CONNECTION (LOCATED ON THE EA OF UNIT) E E2 N BC BC LINE 5B WHITE GEEN 5B 28 AND LATE AI-COOLED HSB GENEATOS EXPLODED VIEW: GEN EADY LOAD CENTE DAWING #: G4744 METE SOCKET BC- L GOUND BA GENEAC NEUTAL BA BC-LINE DUPLEX BEAKE GEN-EADY LOAD CENTE EVISION: H-2827-D DATE: 9/8/8 PAGE 2 OF 4 2 of 3

N 5A 5A A A INTECONNECTIONS Geneady Load Center and Transfer Switch N QT SEIES ENGINE GENEATO CONNECTION PANEL ALL WIING TO BE MINIMUM 8AWG, 3VAC ATING. ECOMMENDED WIE TYPE: THHN GENEAC P/N G4746 FUSE W/HOLDE G858E DECAL POWE LEADS AND TANSFE SWITCH LEADS MUST BE UN IN TWO DIFFEENT CONDUITS. EXCEPTIONS: IF THE INSULATION ATING ON ALL WIING IS ATED FO 6V AND THE LENGTH OF THE CONDUIT IS 3ft O LESS IT IS ACCEPTABLE TO INCLUDE GENEATO CONTOL & POWE WIING IN ONE CONDUIT. GOUP G NOT USED IN THIS APPLICATION N 94 TNS SW WIE TNS SW WIE 94 E E2 3 5A 8 ON CUSTOME CONNECTION 4 5 6 7 NOTE: 78 AND 83 CONNECTIONS AE TB 2 M STT WIE 83 M STT WIE 78 EXPLODED VIEW: GEN EADY LOAD CENTE DAWING #: GOUND NEUTAL METE SOCKET BC- L GENEAC NEUTAL BA GOUND BA BC-LINE DUPLEX BEAKE GEN-EADY LOAD CENTE NOTE: INSTALLATION TO BE DONE BY A LICENSED ELECTICIAN AND MUST MEET ALL NATIONAL, STATE AND LOCAL ELECTICAL CODES. EVISION: H-2827-D DATE: 9/8/8 PAGE 3 OF 4 3 of 3

UNIT DIMENSIONS Geneady Load Center and Transfer Switch 4.38 5.63 4 Outside Dimensions of Enclosure Shell Front Cover & Door 42 43.25 Equipment Ground Utility Generator Transfer Operator Bonding Connection Neutral

SPECIFICATIONS Geneady Load Center and Transfer Switch Enclosure...NEMA Type, general purpose, painted metal Main Breaker... 2 Amp Generator Switch... Amp Main breaker wire size... # to 3 mcm Cu-Al Generator switch wire size...# 2 to / Cu, /-2/ Al Neutral Lug... # 6 to 3 mcm Ground Lug... # 4-2/ Ground Fault or Arc Fault Circuit Breaker... QPF or QAF Siemens Maximum number of circuits (standard " breakers / tandem /2" breakers) Protected circuits...8/3 Non-protected circuits.../na Total circuits...28/4 Withstand rating Main bus (amps)...22, Meets NEC wire bending space...yes UL listed...yes Seismically qualified to meet UBC code...yes Weight Geneady Basic w/o EZ transfer operator (Geneady Advanced with EZ transfer operator)...45.5 lbs. (49 lbs.) Operating temperature range...-2º F to 4º F Generac Power Systems, Inc. S45 W2929 HWY. 59, Waukesha, WI 5389 generac.com 29 Generac Power Systems, Inc. All rights reserved. All specifications are subject to change without notice. Bulletin 752SBY/Printed in U.S.A. 3.8, rev: 3.9