NEW ZEALAND POST OFFICE NEGATIVE 50V D.C. TO POSITIVE 50V D.C. SUPPLY NOTES PR 2157 ISSUE 1 APRIL 1977

Similar documents
lectronic starter for single phase duction motor

2.0 CONSTRUCTION 3.0 OPERATION. SA-1 Generator Differential Relay - Class 1E 2.5 TRIP CIRCUIT

Ceramic PTC Thermistor:

Maintenance Manual 13 AMPERE POWER SUPPLY 19A704647P1-P3. Mobile Communications LBI-31801C

OPERATING AND MAINTENANCE MANUAL. Primary Current Injection Test Set. 750ADM-H mk2

James Hamilton Electrical Pty Ltd (Inc in Qld) A.C.N trading as. Power Drive Systems. Generator Control Specialists

EPS/ELA-Series User Manual EPS/ELA 250W

Understanding The HA2500's Horiz Driver Test

3. OPERATION 2.1. RESTRAINT CIRCUIT 2.6. INDICATING CIRCUIT 2.2. OPERATING CIRCUIT 2.7. SURGE PROTECTION CIRCUIT 2.3.

User Guide 4Q kW D.C.Motor Regenerative Speed Controller. Part Number: Issue Number: 3

OVERLOAD PROTECTION. All electrical circuits must have some means of protecting against overload.

CHAPTER 4 PROTECTION REQUIREMENTS

SDC,Inc. SCR-Regenerative Ac Drive

Induction Power Supply Technical/Service manual for 12.5kW-40kW/480V input 2012

R-MAG Vacuum Circuit Breaker with Magnetic Actuator Mechanism 15.5 kv - 27 kv; 1200 A A

DEEP SEA ELECTRONICS PLC

Lecture 2. Power semiconductor devices (Power switches)

PPS20 COMMUNICATIONS POWER SUPPLY AND BATTERY MANAGEMENT SYSTEM

Crompton Controls. This is. Installation and Maintenance Instructions. S10 & Smooth-BRAKE DC Injection Brake Modules. Tel: +44 (0)

Data Bulletin. Ground-Censor Ground-Fault Protection System Type GC Class 931

DEEP SEA ELECTRONICS PLC

R-MAG. Vacuum Circuit Breaker with Magnetic Actuator Mechanism

Professional Wireless Products

RE-PR3-E-86&105 3-Phase Panel Mount 86 and 105kW

AUTOMOTIVE MAINTENANCE TECHNOLOGY SUBJECT: AUTOTRONIC 2 TITLE: BREAKER-TRIGGERED TRANSISTORISED IGNITION TI-B

Functions provided by measuring relays in railway equipment

TRIPS AND FAULT FINDING

INDEX Section Page Number Remarks

Features. Description. Table of Contents

Working Principle of Earth Leakage Circuit Breaker (ELCB) and Residual Current Device (RCD)

INSTALLATION & OPERATING MANUAL RW SERIES WALL-MOUNT RECTIFIERS

Question Number: 1. (a)

DYNAMO & ALTERNATOR - B FIELD LOGIC PROBE.

2. AC SERVICE AND MOTOR REQUIRED 1. ENCLOSURE REQUIRED

AIR COOLED RECTIFIER SPECIFICATION S-50-A

Principles of Electrical Engineering

ISO Rules Part 500 Facilities Division 502 Technical Requirements Section Interconnected Electric System Protection Requirements

World Class Power Solutions. Rectifiers. For Stationary Battery Systems in Nuclear Power Plants

702 AUTOMATIC START MODULE OPERATING INSTRUCTIONS

Burden Fuse Rating Resistor SAF / SAK6 1NM 10mm M8 12NM SAF / SAK10 2NM 16mm M8 12NM

EST Electrical Service Technician Answer Schedule

RT2DB Excitation and voltage regulation system for synchronous generators

INSTALLATION, OPERATION & MAINTENANCE SERIES ABC11B-120-XX BATTERY CHARGERS

ELECTRICAL SERVICE TECHNICIAN EXAMINATION 25 November 2017 QUESTION AND ANSWER BOOKLET

ABB ! CAUTION. Type KRV Directional Overcurrent Relay E 1.0 APPLICATION 2.0 CONSTRUCTION AND OPERATION. Instruction Leaflet

SURE-TRIP OEM RELACEMENT TRIP UNIT

Model ER-340XRi / ER-680XRi / ER-1220XRi DC drive product manual HG iss 9 1

Thyristors Characteristics

Tattletale Annunciators and Magnetic Switches

Model 340i / 680i / 1220i DC drive product manual HG iss 8 1

ABB Automation Inc. Substation Automation and Protection Division Coral Springs, FL 33065

Application Note CTAN #127



1. DBS series. Applications Manual

PORTABLE CURRENT SOURCE FOR CIRCUIT BREAKER AND MOTOR OVERLOAD TESTING INSTRUCTION MANUAL PI-250B. Release 1.0 April 5, 2013

KV4-300 mk2. KV5-200 mk2. KV5-100T mk2. KV3-250 mk2

Induction Power Supplies

TYPE KF UNDER-FREQUENCY RELAY A. Figure 1: Type KF Relay for 60 Hertz without Case. (Front & Rear View.) Front View Rear View

SECTION MOTOR CONTROL

Single or Double 240VAC motor control for domestic and industrial gates and doors.

Electronic Dynamo Regulator INSTRUCTION MANUAL. COPYRIGHT 2014 CLOVER SYSTEMS All Rights Reserved

Table of Contents. VLT 5000 Series Service Instructions. Introduction Product Overview Warnings and Cautions... 1

Brake Pack SB50W. Standard AC Motors A-143. Standard AC Motors Intro duction. Brake Pack. AC Speed Control Motors Inverter.

LED Flasher. R1 R2 100 F + C1 100 F +

Adapted from presentation developed by Scott Fausneaucht

Electrical operating instructions

HP21 SERVICE SUPPLEMENT UNIT INFORMATION. TSC6 Two-Speed Control

Electronic Dynamo Regulator INSTRUCTION MANUAL. COPYRIGHT 2014 CLOVER SYSTEMS All Rights Reserved

BASIC ELECTRICAL MEASUREMENTS By David Navone

revised September 11, 1997

SURE TRIP RETRO KITS

HCM25 Portable Sub-Sea MPI System Data Sheet

Direct On Line (DOL) Motor Starter. Direct Online Motor Starter

to allow a current in one circuit to operate a switch in another circuit to protect a circuit by melting if the current becomes too large

Exercise 1-5. Current Protection Devices EXERCISE OBJECTIVE DISCUSSION OUTLINE DISCUSSION. Circuit breakers

SECTION 4 ELECTRIC MOTORS UNIT 17: TYPES OF ELECTRIC MOTORS UNIT OBJECTIVES UNIT OBJECTIVES 3/21/2012

Unit Protection System for Pumped-Storage Power Stations

Horizontal Circuit Switchers

3.5 Amp Bi-polar stepper motor drive MSE570 Evo 2

Model HEA Multicontact Auxiliary

SALDET SALES & SERVICE, INC. CLINTON TOWNSHIP, MICHIGAN

Pan Hao Co., Ltd. How to operate IGBT modules in parallel properly

Horizontal Circuit Switchers

Security alarms, warning systems.

Products Tde Macno. User s Manual BRAKING UNIT. Cod. MP00401E00 V_1.0

WIRING THE HEATER POWER SUPPLY

GENERATION, CONVERSION, OR DISTRIBUTION OF ELECTRIC POWER

EMX or EMK POWER SUPPLY

Dycon D2430 EN54-4 Fire Alarm Power Supply Series

MX431 Generator Automatic Voltage Regulator Operation Manual

Learning Objectives:

USD ,4A 42Vdc Bipolar Driver

2.0 CONSTRUCTION AND OPERATION 3.0 CHARACTERISTICS K. CO (HI-LO) Overcurrent Relay

DPX moulded case circuit breakers

Boston Gear Ratiotrol

Lecture 20: Stator Control - Stator Voltage and Frequency Control

A200 NEMA Contactors and Starters A200

DENVER PUBLIC SCHOOLS DESIGN AND CONSTRUCTION STANDARDS This Standard is for guidance only. SECTION MOTORS, STARTERS & DRIVES

ABB Power T&D Company Inc. Relay Division Coral Springs, FL Allentown, PA. Non-Directional, Single Phase Adjustable Time Delay Device No.

Transcription:

NEW ZEALAND POST OFFICE NEGATIVE 50V D.C. TO POSITIVE 50V D.C. SUPPLY NOTES PR 2157 ISSUE 1 APRIL 1977 1. GENERAL. 1.1 These PR notes supersede notes PR 2133 and should only be used in conjunction with the attached schedule of drawings. 1.2 The power supply can be used for all applications where plus 50V at up to 1A is required. Efficiency at full load is generally better than 70% and load regulation better than 5% from 1 / 10 load to full load. 1.3 The supply operates on a one plus one redundancy basis and contains two separate -50V/+50V d.c. - d.c. converters, a changeover and alarm circuit, a voltage alarm unit and a converter current limit circuit. In the event of one of the converters failing, automatic changeover to the second converter is effected, the yellow LED lights up and an alarm is extended. If the second converter fails the red LED lights up and a second alarm is extended. The current limit circuit limits the maximum output to approximately 1.5A and has a thermal trip mechanism to prevent thermal overload. This will operate after some 8 minutes on a direct short circuit. The voltage alarm unit monitors the system output and will give an alarm if the voltage rises or falls outside the set limits. The converter fail alarms can be reset with the reset key mounted inside the supply cabinet. Note that this reset key will not restore the thermal trip circuit. 2. ASSOCIATED DRAWINGS. 2.1 NZPO 40982-50V/+50V D.C. to D.C. Power Supply Circuit. NZPO 40980-50V/+50V D.C. to D.C. Converter Circuit. NZPO 40978-50V/+50V D.C. to D.C. Converter Fail, Changeover and Alarm Circuit. NZPO 40979-50V/+50V D.C. to D.C. Current Limit Circuit. NZPO 40435-50V/+50V D.C. to D.C. Power Supply General Construction Details. NZPO 40977-50V/+50V D.C. to D.C. Power Supply Mechanical Details. NZPO 40462 Voltage Alarm Unit Mk II. 3. DESCRIPTION. 3.1 The power supply which is housed in a 24 by 12 Gael cabinet contains two -50V/+50V converters on a gear plate and the current limit circuit. Also mounted on the gear plate are the terminal block, reset key and auxiliary tag board. The converters are easily removed in case of failure and a replacement fitted. 4. INSTALLATION. 4.1 The supply should be located indoors and mounted in a position which will not impede air flow through the cabinet. The temperature of air entering the bottom of the cabinet must not exceed 40 C.

Page 2 4.2 The supply is fixed to the wall by removing the gear plate and screwing the cabinet securely through the four holes at the rear of the cabinet. 4.3 There are seven external connections to the supply and these are terminated on the 8 way terminal block. Terminal T1 Terminal T2 Terminal T3 Terminal T4 Terminal T5 Terminal T6 Terminal T7-50V Battery Input. Earth. Earth. +50V D.C. Output. Converter 1 Fail Alarm Output. Converter 2 Fail Alarm Output. System Fail Alarm Output. 5. SETTING UP AND TESTING. 5.1 The only setting up required is the adjustment of voltage alarm unit. This unit should be adjusted in accordance with the PR notes to the following limits :- High Volts - Not Used, turn H.V. pot fully clockwise. Low Volts - 42.0 V 5.2 The following procedure is to be used to obtain the correct voltage for setting up the voltage alarm unit. 5.2.1 Remove fuses FS1 and FS2. 5.2.2 Connect a variable 50V power supply between the converter side of FS1 and earth. 5.2.3 Connect a meter between the output terminal T4 and earth. 5.2.4 Adjust the power supply so that the output voltage reads the required 42.0 volts. 5.2.5 Adjust the voltage alarm unit in accordance with notes PR 2094 Issue 3. 5.2.6 Remove the power supply and meter and replace the fuses FS1 & FS2. 5.2.7 The changeover and alarm circuit is checked by removing fuses FS1 and FS2 and checking that the converter fail LED s light up. Replace the fuses and reset both converters by operating the reset key to Reset 1 then Reset 2. This completes the setting up and testing. 6. CIRCUIT EXPLANATORY. 6.1 D.C. to D.C. Converter. (Ref NZPO drg 40980)

Page 3 Assume transistor TR1 is off and TR2 is on and the transformer saturated. When TR1 starts to conduct, the voltage developed across the primary winding Np induces voltage in the feedback winding Nf such as to rapidly drive TR1 into saturation and turn TR2 off. When this is completed, a constant voltage Vp = Vcc -Vce (sat) is applied to Np. Since d = Vp flux must increase in the transformer at a constant dt Np rate causing the flux density to increase from point C towards D on the BH curve in Fig 1. E FLUX DENSITY D MAGNETIC FLUX F C Fig 1 As long as the core remains non-saturated, the magnetisation current Im = Hl is small but as saturation Np point (point D) is approached a large magnetisation current Im is required to keep d constant( l = dt magnetic path length). When the reflected load current plus the sharply increasing magnetising current exceed the collector current TR1 can supply with the available drive, TR1 comes out of saturation causing Vp to decrease and the field to collapse thus ending the half cycle. The process is then repeated for TR2. R2 provides the bias for TR1 or TR2 on startup and R1 regulates the amount of base drive current available. Capacitors C4 and C5 are speed-up capacitors which aid the transistors to switch from the off to the on state and vice versa. C1, C2 and L1 form a pi section filter to reduce noise on the battery supply. R3 and C5 help damp any ringing and spikes in the collector voltage waveform. The square wave output is rectified by diodes D2-D5 which are fast recovery diodes and is smoothed by capacitor C6. It must be noted that some adjustment of resistors R1 and R2 may be necessary to achieve optimum performance during manufacture or subsequent servicing due to the spread of transistor characteristics. To minimise this, matched pairs of transistors should be used. R1 is adjusted for best efficiency whilst still providing sufficient base drive on full load (see fig 2) and R2 is adjusted so that the converter will start will start under full load conditions. R2 should be approximately 80 times R1.

Page 4 COLLECTOR - COLLECTOR VOLTAGE WAVEFORMS Insufficient Base Drive To Much Base Drive Fig 2 6.2 Converter Fail, Changeover and Alarm Circuit. (Ref NZPO drg 40978) This circuit is designed to monitor the output of the operating converter and, if a failure occurs, switch over to the other converter and extend an alarm. If failure of the second converter occurs, a second alarm is extended. R1 and OPT1 ( a photo darlington) monitor the output voltage of the first converter. When the output voltage and hence the current fails, the darlington transistor pair in OPT1 is turned off which allows the voltage divider chain of R2, R3 and R4 to bias SCR1 into conduction and hence operate relays RLA and RLC. Once triggered, the SCR will stay latched until the supply is interrupted by pushing the reset button. C1 is to prevent spurious triggering by noise. When RLA is operated, LED1 is turned on and an alarm is extended via contacts RLA2 and RLA1 changes over the input from converter 1 to converter 2. At the same time RLC1 releases the short circuit on SCR2 which allows the alarm circuitry for converter 2 to come into operation. The alarm circuit for converter 2 is identical to that of converter 1 except that a small time delay via C3 is included to prevent it operating at the instant of changeover. If converter 2 fails the a second alarm is extended via relay contacts RLB1 to LED2 (red) and the input to converter 2 is disconnected by RLB2. 6.3 Auxiliary Tag Board. This tag board contains the two steering diodes which serve to isolate the alarm circuitry from the section which it is not monitoring. 6.4 Current Limit Circuit. (Ref NZPO drg 40979) This circuit is designed to monitor the output current of the converter and prevent it exceeding 1.5A under overload conditions. Transistor TR1 is normally turned hard on by TR2, T1 and R2. When the current in the output circuit exceeds 1A the voltage developed across R1 turns on TR3 which causes the voltage at the base of TR2 to be reduced. This brings TR1 out of saturation and limits the current available to the output circuit. When the output current falls below 1A, TR1 is automatically turned hard on and the circuit is back to normal.

Page 5 Microtherm T1 is attached to TR1. The contacts of the microtherm are normally closed and open when the case temperature exceeds 125 C. This ensures that the temperature of TR1 and Heatsink under fault conditions does not exceed the ratings of TR1. 6.5 Voltage Alarm Unit. (Ref NZPO drg 40462) See Notes PR 2094 Issue 4