Shhhhhhhhhhh! Here there is silence.

Similar documents
TD-SILENT Series (160 to 1000 models)

Ultra-quiet circular duct fans TD-SILENT ECOWATT Series

TD-SILENT range, the quietest fans in the world in their class

TD-SILENT range, the quietest fans in the world in their class

MVF S.r.l. Via San Giovanni Bosco, Alessandria Tel Fax Web:

Versatility. Features. By installing the SILENT MV, you will never experience the disturbance of noisy ventilation again. Benefits

TD-ECOWATT AND DECOR-ECOWATT Series

SILENT MV Ultra Quiet In-line Fans

IN-LINE MIXED FLOW DUCT FANS MIXVENT-TD Fan Systems

IN-LINE DUCT FANS MIXVENT-TD Fan Systems

TD-MIXVENT Series IN-LINE MIXED FLOW DUCT FANS TD-MIXVENT. In-Line duct fans

MTD Silent Series MIXED FLOW IN-LINE DUCT FAN

BPF. Centrifugal Plug Fans

MODEL TD-MIXVENT INLINE MIXED FLOW DUCT FAN

IN-LINE MIXED FLOW DUCT FANS TD-MIXVENT Series

Practical examples of installation in the TD range

IN-LINE MIXED FLOW DUCT FANS TD-MIXVENT Series

Inline Fans Options Featuring TD-MIXVENT/TD-SILENT

ACOUSTIC CABINET FANS Centribox CVB-CVT Series, Forward Curved Centrifugal Fans

Inline Fans Options Featuring TD-MIXVENT/TD-SILENT

BDB. Double Inlet Centrifugal Fan. with Backward Wheels

Soler & Palau. Research Design and High Technology

MODEL TD-MIXVENT INLINE MIXED FLOW DUCT FAN

Introducción Introduction

Short casing. Long casing (L version) Commercial premises

ADA. Double Inlet Centrifugal Fan. with Airfoil Impellers

BATHROOM EXTRACT FANS DECOR-100 Series

MODELS FF & FFC CEILING AND INLINE/CABINET VENTILATORS

EDM-80N EDM-80L EDM-100 EDM-200. Installation examples. Extract ventilation through short duc

series RVV Variable flow rate controllers

MODEL FF/FFC CEILING AND INLINE/CABINET VENTILATORS

EDM Series EDM-80N EDM-80L EDM-100 EDM-200 AXIAL BATHROOM FANS. Bathroom extract fans EDM

supplied in Form (B) configuration. Airflow over Impeller- Motor.

CENTRIFUGAL DIRECT DRIVE FANS CMT-CMB

plates and with flexible conduit. Ø Outlet (mm)

ROOF MOUNTED FANS MIXVENT-TH Series Mixed Flow Fans MIXVENT-TH. Roof mounted fans. Flame retardant terminal box. Circular spigot coupling

ACOUSTIC CABINET FANS CVB / CVT Series

ACOUSTIC CABINET FANS CENTRIBOX CVB/CVT. Acoustic cabinet fans. Circular duct connection flanges. Flame retardant IP55 remote terminal box

MODEL FF/FFC CEILING AND INLINE/CABINET VENTILATORS

HIGH TEMPERATURE TWIN SQUIF FANS

Soler & Palau. Research Design and High Technology

HXBR / HXTR Series PLATE MOUNTED SICKLE BLADE AXIAL FANS WITH EXTERNAL ROTOR MOTOR. Plate mounted axial flow fans HXBR/HXTR. Corrosion resistance

NALSRF BELT DRIVE ACOUSTIC SINGLE EXTERNAL ROOF FANS

IN-LINE CENTRIFUGAL DUCT FANS VT Series

MODELS FF & FFC CEILING AND INLINE/CABINET VENTILATORS

CONFIGURABLE HIGH-EFFICIENCY HEAT RECOVERY UNITS CADB/T-HE PRO-REG Series

Air Curtains for Revolving Doors

PH SERIES SINGLE DUCT ATU PERFORMANCE DATA

BSB. Single Inlet Centrifugal Fan. with Backward Wheels

CENTRIFUGAL FANS. Single Width, Single Inlet WFS & WBS Series WTC TECH CO., LTD. CENTRIFUGAL FANS Single Width, Single Inlet WFS & WBS Series

FDA Double Inlet Centrifugal Fan. with Forward Wheels

Circular Silencer. Rigid and flexible construction Type CA CB CF CS. TROX GmbH Telephone +49/28 45/ Telefax +49/28 45/

series Silencers

CAV controllers. Type EN. For the precise control of normal and high constant volume flows. 01/2017 DE/en PD EN 1

FAN POWERED TERMINAL UNITS

New standard decorative generation

PERPIGNAN FRANCE FIGUERES PUIGCERDÀ RIPOLL

ROOF MOUNTED FANS TH-MIXVENT Series Mixed Flow Fans TH-MIXVENT. Roof mounted fans. Flame retardant terminal box. Circular spigot coupling

200, 9200 & 9200-VIB SERIES

Ceiling Mount Type Ventilating Fan

Indoor Console. Slim Design This is only 199mm thick, the slimmest on the market. Its slim design easily integrates the unit into your décor.

FDA. Double Inlet Centrifugal Fan. with Forward Wheels

CAV controllers. Type EN-Ex. For the precise control of normal and high constant volume flows in potentially explosive atmospheres (ATEX)

FDCLP2 Constant Volume Series Flow, Low Profile

RETROFIT TERMINAL UNITS

CENTRIFUGAL IN-LINE FANS VENT Series

COMPACT CAGE RACK VALVES

VENT Series CENTRIFUGAL IN-LINE FANS VENT. In-Line duct fans. Mounting foot

Mancoolers Models MCY, MCB, MCP

AHN 064 to 304 EHN/CHN 064 to 304

KSOM Control exhaust valve

AIR VENT T E C H N O L O G Y. infinity. energy efficient - environmentally friendly - economical EC MOTORS - direct drive - CuSTOM built ErP Compliant

NCF fans 50 Hz. Protection class IP 55

CAV controllers. Type VFL. Volume flow limiter for insertion into ducting PD VFL 1

VORTICE VARIO I RANGE Flush mounted axial fans

Ducted medium static pressure monosplit DC Inverter

ACOUSTIC CABINET FANS CVAB / CVAT Series

VORT QUADRO RANGE CENTRIFUGAL EXTRACTOR FANS FOR WALL/CEILING INSTALLATION AND FLUSH MOUNTING WITH OPTIONAL SIDE EXTRACTION

CAV controllers. Type RN. For the precise control of constant volume flow rates PD RN 1

500-YVI PARALLEL FAN-POWERED AIR TERMINAL UNIT FORM EG3 (404)

Engineering Data Manual. New : available with EC motor. High Static Pressure Ductable Fan Coil Unit. Models 07 to to 4650 m 3 /h

VAV Terminal Units SDS

Driving and Connecting Globally. Fan Coil Unit. Model : PHW-K Size : 510CMH~2720CMH. Made in Taiwan

CMB / CMT Series CENTRIFUGAL SINGLE INLET FANS. Centrifugal direct drive fans CMB/CMT 80 C. Impeller dynamically balanced

500-YCI SERIES FAN-POWERED AIR TERMINAL UNIT FORM EG2 (404)

technical data air conditioning systems Round Flow Cassette FXFQ-P9VEB

DOMESTIC RANGE DOMESTIC FANS. Perimetral bathroom fans. Axial bathroom fans. Centrifugal bathroom fans WALL FANS

Circular Box Fans - DAISHO EC Range DAISHO EC 125. Features. Electrical Supply. Product Code. Sizes 125, 150, 200, 250, 315, 450, 630 and 1000.

ATU PRODUCT CATALOG AIR TERMINAL UNITS FCI-600 CONSTANT VOLUME FAN TERMINAL UNIT Metal Industries, Inc.

ceiling & inline/cabinet ventilators

MAJOR 2 NCH. Ductable units. High pressure and high capacity ductable units RANGE NCH Y NCH NCH I COADIS COMBI. Motor optional

Measuring probe For ventilation and air-conditioning Model A2G-FM

MIXVENT-TH Series Mixed Flow Fans

Air Flow Solutions. Commercial Fans Offices, retail, leisure, education

CAV controllers. Type VFL. Volume flow limiter for insertion into ducting K

CEILING & INLINE/CABINET VENTILATORS

CVAB / CVAT Series ACOUSTIC CABINET FANS CVAB / CVAT. Acoustic cabinet fans. Backward curved centrifugal impellers.

BHW MEDIUM STATIC PRESSURE DUCTABLE TYPE TECHNICAL CATALOGUE

VORT QUADRO RANGE. Design: F. Trabucco & Associati

Specifications. Applications Ventilation of safety cabinets (STORM 10), scrubbers, fume capture arms, filter housing, etc. (STORM 12, 14, 16).

Transcription:

TD SILENT RANGE Shhhhhhhhhhh! Here there is silence. New TD Silent range. The world s most quiet fans in its class.

TD SILENT range: A leap in time. S&P, a world leader in ventilation, presents the world s most quiet in-line fans range in it s class. The world s most quiet fans in its class. A quantum leap based on our long experience in this type of fans and hundreds of hours of research with a clear objective: improving the quality of life and a clear result: up to 12 db (A) less than our major competitors. Install it to your customers: simply they will forget it exists Install quietness, install quality of life, with TD SILENT fans, your customers will feel the satisfaction that the ventilation system does not interfere with their daily tasks. Connection Rubber gasket Sound-absorbent cover The TD Silent range is the result of a great human, technological and economic investment to offer S&P clients an extremely high-performance product with significant noise reduction compared to other similar products on the market. Many hours of aerodynamic testing have enabled us, not only to reduce the noise produced, but also to ensure that the noise actually emitted is within less disturbing frequencies for the human ear, so that installations using TD Silent offer a greater level of comfort for the user. Sound deadener External casing Mounting Feet Support brackets

State of the art technology has been used to design TD SILENT, both in the design software and the use of twin-material injection to achieve results that will satisfy even the most demanding professional. A layer of sound-absorbent material to deaden noise generated during normal operation of the device. Twin-material support brackets, which in addition to simplifying installation, serve as joint seals. Connection box can be rotated 36º, to facilitate entry of the power cable Twin-material support brackets, which in addition to simplifying installation, serve as joint seals. Support bracket for installing on a wall or ceiling, incorporating twin-material support brackets for the motor section that absorb vibrations. A specifically designed internal coating to direct the sound waves in the right angle for them to be captured by the sound-absorbent material. Sound waves produced inside the TD, are directed through the perforated inner cover and absorbed by the layer of sound-absorbent material.

Low profile helicocentrifugal fans with sound-absorbent insulation, manufactured in plastic material with an external connection box, a body that can be dismantled and an adjustable 23 V 5 Hz motor, fitted with rubber gaskets on the inlet and outlet to absorb vibrations. (Excepto TD-16 SILENT que incorpora el sistema de motor flotante patentado por S&P) Easy installation Loosen fixing clamps Open clamps on both sides Remove the fan body Remove the terminal box lid. Carry the wiring of the unit Mount the fan body again by tightening the clamps Technical Characteristics Model Nom. speed r.p.m. Maximum absorbed power at Pa. (W) Maximum absorbed current (A) Duty at free discharge (m 3 /h) Maximum operating temp. (ºC) Sound pressure level* (db(a)) Ø Duct (mm) TD-16/1 N SILENT 25 22 2 12,16,1 18 14 4 24 21 1 TD-25/1 SILENT 22 185 24 18,11,1 24 18 4 24 19 1 TD-35/125 SILENT 225 19 3 22,13,1 38 28 4 19 19 125 TD-5/15-16 SILENT 25 195 5 44,22,19 58 43 6 22 17 15 /16 TD-8/2 SILENT 278 248 7 6,3,26 88 7 6 19 18 2 TD-1/2 SILENT 25 2 12 1,5,45 11 8 6 21 2 2

TD Silent 23V 5 Hz Air volume in m 3 /h and m 3 /s Static pressure in Pa Absorbed power in W Air flow data in accordance with the following standards: UNE 1-212-89, BS 848 Part 1, AMCA 21-85 and ASHRAE 51-1985 P s (Pa) 12 1 8 LS Pabs (W) 6 TD-16/1 SILENT 5 4 P s (Pa) 16 14 12 LS 1 Pabs (W) 8 TD-25/1 SILENT 7 6 5 6 C 3 8 C 4 4 2 F E B 2 1 6 4 2 F E B 3 2 1 2 4 6 8 1 12 14 16 18 Q(m 3 /h)..1.2.3.4.5 Q(m 3 /s) D A 4 8 12 16 2 24 Q(m 3 /h)..1.2.3.4.5.6.7 Q(m 3 /s) D A A 24 32 39 46 52 49 4 31 54 34 B 23 32 4 46 51 47 39 3 54 33 C 23 34 43 47 51 47 39 3 54 33 A 24 24 37 34 36 41 32 21 44 24 B 23 24 38 35 35 39 31 2 44 23 C 23 26 41 36 35 39 31 2 44 24 A 3 34 37 48 51 47 41 31 54 33 B 29 35 37 48 49 46 39 3 53 33 C 28 36 39 49 5 45 39 3 54 33 D 23 26 37 43 49 45 36 27 51 31 E 22 27 39 43 47 43 35 26 5 3 F 22 29 41 44 48 44 35 27 51 31 D 23 17 35 32 33 37 28 17 41 2 LS E 22 18 37 32 31 36 27 17 41 2 F 22 21 39 33 32 36 27 17 42 22 D 29 32 34 45 48 44 37 27 51 3 E 28 32 35 45 46 42 35 27 5 29 F 28 33 36 46 47 42 36 27 51 3 A 26 32 46 53 53 44 38 3 57 36 B 24 36 46 53 52 44 38 3 56 36 C 25 35 42 51 55 47 4 34 57 37 A 26 28 4 4 36 31 25 18 44 24 B 24 32 4 4 35 31 25 18 44 24 C 25 31 36 38 38 34 27 22 43 23 A 3 33 45 53 46 4 36 28 55 34 B 26 35 43 52 45 4 36 28 54 33 C 26 35 39 51 49 42 38 31 54 33 D 22 38 42 47 48 38 32 26 52 31 E 23 34 43 46 48 39 32 27 51 31 F 24 33 39 49 54 43 35 29 56 35 D 22 33 35 34 28 24 19 17 39 19 LS E 23 29 36 33 28 25 19 18 39 19 F 24 28 32 36 34 29 22 2 4 2 D 26 36 4 47 41 34 29 24 49 29 E 25 34 41 46 42 35 31 25 49 28 F 25 33 38 49 46 37 33 26 51 31 *Sound pressure level radiated at 3 m. in free field condition, with rigid ducts at the inlet and outlet.

TD Silent 23V 5 Hz Air volume in m 3 /h and m 3 /s Static pressure in Pa Absorbed power in W Air flow data in accordance with the following standards: UNE 1-212-89, BS 848 Part 1, AMCA 21-85 and ASHRAE 51-1985 P s (Pa) 16 14 12 LS 1 Pabs (W) 8 TD-35/125 SILENT 7 6 5 P s (Pa) 3 25 LS 2 Pabs (W) 18 TD-5/15-16 SILENT 15 12 C 8 6 4 2 F C E B 4 3 2 1 15 1 5 F E B 9 6 3 5 1 15 2 25 3 35 Q(m 3 /h)..2.4.6.8.1 Q(m 3 /s) D A 1 2 3 4 5 6 Q(m 3 /h)..4.8.12.16 Q(m 3 /s) D A A 22 28 41 53 49 44 37 3 55 35 B 22 27 39 51 49 42 37 3 54 33 C 23 31 48 53 51 46 41 32 56 36 A 22 23 32 39 32 25 18 14 41 2 B 22 22 3 37 32 23 18 14 39 19 C 23 26 39 39 34 27 22 16 43 22 A 29 3 43 53 5 45 38 3 56 35 B 25 27 4 5 47 4 36 29 52 32 C 24 31 46 52 47 42 4 32 54 34 D 21 27 42 46 51 38 31 25 53 32 E 22 29 4 46 53 39 34 26 54 34 F 3 33 41 51 52 46 4 33 55 35 D 18 22 34 33 34 2 13 13 39 18 LS E 19 24 32 33 36 21 16 14 39 19 F 27 28 33 38 35 28 22 21 41 21 D 24 27 43 45 46 38 3 25 5 29 E 23 29 4 45 47 35 32 26 5 29 F 29 34 41 49 46 41 38 31 52 31 A 24 35 51 58 57 56 51 47 63 42 B 25 33 48 56 55 54 46 42 6 4 C 24 33 49 57 53 52 46 4 6 39 A 12 21 42 39 37 35 23 18 45 25 B 13 19 39 37 35 33 18 13 43 22 C 12 19 4 38 33 31 18 11 43 22 A 38 38 52 6 58 53 49 43 63 43 B 35 35 53 58 57 5 44 38 62 41 C 3 33 5 57 56 48 42 36 6 4 D 28 33 46 54 53 51 45 38 58 38 E 25 31 41 5 48 44 37 3 53 33 F 25 37 48 56 52 49 42 35 59 38 D 23 25 34 37 38 35 26 23 43 22 LS E 2 23 29 33 33 28 18 15 38 17 F 2 29 36 39 37 33 23 2 43 23 D 26 33 47 53 51 47 41 33 56 36 E 25 31 44 5 48 41 33 27 53 33 F 26 37 5 55 5 43 37 31 57 37 *Sound pressure level radiated at 3 m. in free field condition, with rigid ducts at the inlet and outlet.

TD Silent 23V 5 Hz Air volume in m 3 /h and m 3 /s Static pressure in Pa Absorbed power in W Air flow data in accordance with the following standards: UNE 1-212-89, BS 848 Part 1, AMCA 21-85 and ASHRAE 51-1985 P s (Pa) 3 25 LS 2 F TD-8/2 SILENT C Pabs (W) 3 25 2 P s (Pa) 4 35 3 LS 25 C TD-1/2 SILENT Pabs (W) 4 35 3 25 15 15 2 F 2 1 E B 1 15 1 E B 15 1 5 5 5 5 2 4 6 8 Q(m 3 /h)..5.1.15.2.25 Q(m 3 /s) D A 2 4 6 8 1 Q(m 3 /h)..5.1.15.2.25.3 Q(m 3 /s) D A A 27 4 48 57 61 61 57 5 66 45 B 25 38 46 55 58 58 54 46 63 42 C 23 38 47 57 59 58 53 48 64 43 A 12 31 29 35 37 36 24 18 42 21 B 1 29 27 33 34 33 21 14 39 19 C 8 29 28 35 35 33 2 16 4 19 A 49 5 51 59 62 62 59 51 67 47 B 42 45 49 58 59 58 55 47 64 44 C 36 42 5 58 59 57 54 47 64 43 D 25 37 48 55 61 57 53 46 64 43 E 24 35 48 52 58 54 49 42 61 4 F 29 38 51 58 58 55 5 45 63 42 D 12 26 3 34 38 33 21 15 41 2 LS E 11 24 2 31 35 3 17 11 38 18 F 16 27 33 37 35 31 18 14 41 2 D 45 47 52 56 59 58 54 46 64 43 E 37 45 54 53 55 54 5 42 61 4 F 31 44 54 57 56 53 5 43 62 41 A 28 43 49 58 62 65 61 53 68 48 B 27 42 46 56 6 61 56 49 65 45 C 25 42 47 58 61 61 56 5 66 45 A 14 35 32 36 39 39 27 19 44 24 B 13 34 29 34 37 35 22 15 42 21 C 11 34 3 36 38 35 22 16 42 22 A 5 5 52 59 65 65 61 54 7 49 B 43 46 49 58 61 6 57 5 66 45 C 35 44 51 59 6 59 56 5 65 45 D 27 38 48 54 61 57 53 46 64 43 E 23 37 49 52 59 54 49 42 61 41 F 26 39 52 57 59 56 51 45 63 43 D 14 29 32 33 4 33 21 14 42 22 LS E 1 28 33 31 38 3 17 1 41 2 F 13 3 36 36 38 32 19 13 42 22 D 44 45 53 55 59 58 54 46 64 43 E 35 41 53 52 55 54 5 41 6 4 F 28 4 54 58 57 54 5 44 62 42 *Sound pressure level radiated at 3 m. in free field condition, with rigid ducts at the inlet and outlet.

Dimensions (mm.) TD-16/1 N Silent A B Ø C D Ø E F G H TD-25/1 575 97 252 24 1 25 83 121 TD-35/125 462 123 252 24 1 25 83 121 TD-5/15-16* 484 147 274 221 116 25 96 134 TD-8/2 568 198 327 264 145 34 129 164 TD-1/2 568 198 327 264 145 34 129 164 * Supplied with an additional rubber gasket for facilities in a 16 mm duct.

Practical examples of installing TD SILENT range TD Silent range offers one of the most versatile fan systems on the market today. Due to its flexibility it can be used in a multitude of small or medium fan installations. Especially in places where working people and the ventilation system works for many hours, in these cases the sound level becomes an essential element for comfort. SCO2

Accessories Mechanical accessories MCA Non-return flaps to be installed at the fans discharge. They prevent heat leakages when the extractor does not work. MAR Rectangular Duct Adapters enable to be connected to rectangular ducting. MRJ Grilles mounted at the inlet or outlet of the fan, to prevent the entry of any foreign objects that could damage the fan. MPC. Flow detectors designed to correctly measure pressures at the inlet of series TD devices unaffected by airflow. Electrical accessories REGUL 2 2 speed switch REB Single-phase electronic speed controller. ECOWATT CONTROL Control element for demand controlled ventilation systems in public, commercial residential buildings that automatically modifies the fan speed to adapt it to the needs defined in the system, measured with sensors. VAPZ Electronic single-phase regulator that controls the fan speed with a simple contact (presence detector) or an analogical input, -1 V or 4-2 ma (C 2 probe for relative humidity % RH).

Accessories SCO2-A Ambient C 2 and temperature sensor. SCO2-AD Ambient C 2 and temperature sensor, with display. SCHT-AD Ambient C 2,temperature and relative humidity with display. CPFL-S / CPFL-E Presence Detector for wall fitting, sensitive to infrared radiation by bodies in movement, with a 36º detecting angle. Power supply:1-23 V. TDP-S / TDP-D Presure sensor. Enables you to control the pressure in the fan inlet. Presure range: -25 Pa. Output signal: -1V/4-2 ma REMP Motorides flaps opening proportionally and controlled by the EAS control module. Power supply: 24 VAC or 24 VD, depending on the models.

S&P: Una estrategia global - Una política local Soler & Palau Sistemas de Ventilación S.L.U. Oficinas Centrales C/ Llevant, 4 - Pol. Ind. Llevant 815 Parets del Vallés (Barcelona) www.solerpalau.es consultas@solerpalau.com Servicio de Asesoría Técnica: Tel. 91 11 62 25 - Fax. 91 11 62 29 Red Comercial de Soler & Palau En estrecha colaboración con la habitual red de distribuidores, en nuestras Delegaciones encontrará usted respuesta y asesoramiento sobre nuestros aparatos o su forma de instalarlos y utilizarlos. Barcelona Tel. 93 571939 Fax. 93 571931 Zaragoza Tel. 976 374595 Fax. 976 25816 Sevilla Tel. 95 4258296 Fax. 95 4517665 Granada Tel. 958 41141 Fax. 958 421625 Murcia Tel. 968 262838 Fax. 968 262838 Vigo Tel. 986 28912 Fax. 986 296676 Gijón Tel. 98 5365711 Fax. 98 5336275 Valladolid Tel. 983 49412 Fax. 983 49413 Las Palmas de Gran Canaria Tel. 928 356449 Fax. 928 356448 Madrid Tel. 91 692835 Fax. 93 692855 Valencia Tel. 96 347352 Fax. 96 348325 Bilbao Tel. 94 441685 Fax. 94 4413666 Palma de Mallorca Tel. 971 619457 Fax. 971 61945