Jiangsu Zeversolar New Energy CO.LTD Building 9 No.198, Xiangyang Road, Suzhou, PEOPLE'S RE- PUBLIC OF CHINA

Similar documents
Certificate of Conformity self-generation unit

Certificate of Conformity self-generation unit

Certificate of Conformity self-generation unit

Certificate of Conformity self-generation unit

Harmonic current emissions as EN Harmonic Test Value in Amps % of fund Limit value in Amps

Datasheet of UBS Series Bidirectional Programmable DC Power Source/Load

G83/2 Engineering Recommendation

Solar Grid tied inverter. Power-One Italy S.p.A. Via S. Giorgio 642, Terranuova Bracciolini (AR) - Italy. P acr [W] P acmax [W]

ABB central inverters PVS to 1000 kw

AS/NZS AS/NZS

ABB PV + Storage REACT-3.6/4.6-TL 3.6 to 4.6 kw

ABB central inverters PVS to 1000 kw

Photovoltaics. MPI Hybrid Series

Voice of GM. Company Profile. Certificates. Product Advantages. Technical Parameters. Service. General Manager GoodWe Power Supply Technology Co.

ABB PV + Storage REACT-3.6/4.6-TL 3.6 to 4.6 kw

THREE-PHASE FRONIUS ENERGY PACKAGE. EFFICIENT / High-performance lithium iron phosphate

TEST REPORT DIN V VDE V

TEST REPORT DIN V VDE V

THREE-PHASE. FRONIUS ENERGY PACKAGE / The personal storage solution for 24 hours of sun. EFFICIENT FLEXIBLE REVOLUTIONARY

Technical Report No A Dated

Technical Report No A Dated

THREE-PHASE FRONIUS ENERGY PACKAGE. EFFICIENT / High-performance lithium iron phosphate

Rayleigh Instruments Ltd Raytel House Brook Road Rayleigh Essex SS6 7XH United Kingdom

Technical Report No D Dated

Technical specifications

SAJ Solar Inverter. Sununo Plus 1K/1.5K BENEFITS. Smart and Easy to Use. Flexible and Efficient. Safe and Reliable. Convenient Installation

Technical Report No C Dated

Annex to the Accreditation Certificate D-PL according to DIN EN ISO/IEC 17025:2005

Technical Report No B Dated

Technical Report No Rev. 00 Dated

/ The personal storage solution for 24H sun. / Dynamic Peak Manager. / Smart Grid Ready THREE-PHASE

SolarMax MT series The all-rounder for trade and industry

PC10(WT19) Industrial Pressure Sensor

SolarMax S series (United Kingdom) Maximising solar plant yields can be so easy.

Power Whenever You Need

Asynchronous generators

Mass Combi Ultra 24/ (230 V)

SolarMax MT series. The power pack for maximum yields.

Technical specification agenitor 306 NG

GUIDE FOR MICROGENERATION INTERCONNECTION TO CITY OF MEDICINE HAT ELECTRIC DISTRIBUTION SYSTEM

Energy generation and storage

Application. Battery. Public Grid GS HYBRID INVERTER

SolarMax S series (Australia) Maximising solar plant yields can be so easy.

Technical specification agenitor 404b NG

Technical specification agenitor 408 NG

UL-EU CERTIFICATE EN :2006/A1:2010, EN :2006/A2:2013, EN :2006. Certificate No. UL-EU Page 1/6 Date of Issue

BYD Distributed Energy Storage System (DESS) Integrated Type (European Version)

/ The personal storage solution for 24H Sun. / Dynamic Peak Manager. / Smart Grid Ready THREE-PHASE

SolarMax 50TS/80TS/100TS/300TS. Ready for the future.

up to 63 A (1 module per pole)

5. OVERCURRENT RELEASE (OCR)

Table of Contents. Lucas Nülle GmbH Page 1/7

SolarMax P series The power package for residential solar plants

FRONIUS ENERGY PACKAGE

Technical Report No A Dated

Technical Report No A Dated

THREE-PHASE STORAGE SOLUTION EFFICIENT MODULAR REVOLUTIONARY

INTERCONNECTION STANDARDS FOR PARALLEL OPERATION OF SMALL-SIZE GENERATING FACILITIES KILOWATTS IN THE STATE OF NEW JERSEY

INVEOR "Smart connections." on five levels

water-cooled motor / generator with up to 13 kw continuous power

THE NETHERLANDS (N E D E R L A N D) COMMUNICATION. Approval number: E4-23R Extension number: 00

IECEx Certificate of Conformity

Operation Instructions

Annex 3B COMMUNICATION

Solenoid Valve Island Type 3965

Power Whenever You Need

Green Inverter from. Solar inverters. for Asia. Solar inverters. for Europe. Solar inverters. for America. Solar inverters.

Slim P.C.B. Relays (EMR or SSR) A

Test Result No.1. Lead (Pb) % ND See comment if > % Cadmium (Cd) % ND Mercury (Hg) % ND

MAKING MODERN LIVING POSSIBLE. UniLynx Indoor Installation Manual. ULX 1800i ULX 3000i ULX 3600i ULX 5400i SOLAR INVERTERS

(1,5 modules per pole)

8710 EN. Potentiometric Displacement Sensors. Models 8710, 8711

for the use of SIQ Type Approved certification mark Sl-SIQ BG 004/081 Project file: C DIN Rail Power Supply

TANZANIA BUREAU OF STANDARDS

Universal Interconnection Technology Technology Roadmap Workshop. Associated Barriers to Distributed Generation

Copyright 2003 Advanced Power Technologies, Inc.

Pre-announcement. Transformerless Solar Inverters

Catch Eco Range : Technical Specification Sheet

SOLAR2PS 500 / 630 / 750 kw Three Phase Solar PV Inverter

ORION PLUS three-phase kVA

Standards, Procedures and Policies for Grid Connection

TYPE APPROVAL CERTIFICATE

Retrofit to Single phase / Three phase PV system Micro-grid, UPS, Peak shift, Pure off-grid retrofitting etc multi-working

Integrated Plant Control and Q on Demand 24/7 SUNNY TRIPOWER

Zero-Carbon Innovator

INVT SOLAR INVERTER SHENZHEN INVT ELECTRIC CO.,LTD

TECHNICAL SPECIFICATION FOR INDEPENDENT POWER PRODUCERS. NB Power Customer Service and Distribution. June 2008

PowerValue 11/31 T kva

/ Optimised energy management. / Dynamic Peak Manager. / Smart Grid Ready 12.0 A / 12.0 A 18.0 A / 18.0 A

RULE 21 GENERATING FACILITY INTERCONNECTION APPLICATION SMUD s Distribution System - (SMUD FORM 2655)

COMPLETE SOLUTIONS FOR POWER PROTECTION

Commander SK. Technical Data Guide. Model sizes A to D and 2 to 6. AC variable speed drive for 3 phase induction motors

Definitions. Scope. Customer Generation Interconnection Requirements

1 Low-voltage Power-factor Correction capacitors KNK APPLICATION DESIGN

Summary. Project data. Site data. A. Mulder Construction cc Anton Mulder Birdie Kuilsrivier. Turnberry Village

Three-Phase Soft Starters

Three-phase 200 V series: FRN0025 to 0060C2S-2U Three-phase 400 V series: FRN0013 to 0030C2S-4U

Energy Meters for Solar-Log Product Information

ABB AG, Transformers Active arcing fault protection system for dry-type transformers. ABB Group April 17, 2013 Slide 1

Test Report. CHTC JIAHUA NONWOVEN CO.,LTD No.99,WaGou New Village, Pengchang,Xiantao,Hubei, CHINA

Transcription:

Technical Report No. <70.409.15.042.02-00> F.3 Requirements for the test report for power generation units F.4 Requirements for the test report for the NS protection Dated <2015-05-26> Client: Manufacturing place: Test subject: Jiangsu Zeversolar New Energy CO.LTD Building 9 No.198, Xiangyang Road, 215011 Suzhou, PEOPLE'S RE- PUBLIC OF CHINA Jiangsu ZOF New Energy Co., Ltd. No.588 Gangxing Road, Economic Development Zone, 212200 Yangzhong City, Jiangsu Province, PEOPLE'S REPUBLIC OF CHINA Product: P Grid-connected inverter Type: Zeverlution Pro 33K Test specification: DE-AR-N 4105: 2011 DIN DE 0124-100(DE 0124-100):2012 Purpose of examination: According to annex F3 and F4 in DE-AR-N 4105: TÜ SÜD certification mark specifications Test result: The test results show that the presented product is in compliance with the specified requirements. This technical report may only be quoted in full. Any use for advertising purposes must be granted in writing. This report is the result of a single examination of the object in question and is not generally applicable evaluation of the quality of other products in regular production. Page: 1 of 10 TÜ SÜ D Certification and Testing

1 Description of the test subject 1.1 Function These devices are transformer-less grid-connected P inverters which converts direct current optimized by photovoltaic DC conditioner to alternating current, and it is intended to be connected in parallel with the low-voltage mains to supply common load. They are intended for professional incorporation into P system, and they are assessed on a component test basis. 1.2 Consideration of the foreseeable misuse Not applicable Covered through the applied standard Covered by the following comment Covered by attached risk analysis 1.3 Technical Data Model : Zeverlution Pro 33K P input : AC output : Max. input voltage: d.c. 1000; MPP voltage range: d.c. 270-950; Max. input current: d.c. 2 x 34A; Isc P(absolute maximum): d.c. 2 x 51A; Rated grid voltage: 3/N/PE~ 400 Rated grid frequency: 50Hz Max. continuous output current: a.c. 3 x 48A Max. AC output active power: 33kW Max. AC output apparent power: 33kA Adjustable cos(φ): 0,85ind...1...0,85cap Protection Class Ingress protection Construction Supply connection Weight : I : IP65 : Fixed equipment : Non-detachable power supply cord : 58kg 2 Order 2.1 Date of Purchase Order, Customer s Reference Page: 2 of 10 TÜ SÜ D Certification and Testing

2015.02.04, 7482037727/1000 2.2 Receipt of Test Sample, Location 2015.02.10, 1) Jiangsu Zeversolar New Energy Co., Ltd. Building 9, No.198 Xiangyang Road, 215011 Suzhou, PEOPLE'S REPUBLIC OF CHINA 2) Nanjing CQC - Trusted Testing Technology Co., Ltd. No.99,Wenlan Road, Xianlin University Zone, Xianlin Street, Qixia District, NanJing, China 2.3 Date of Testing 2015-02-10 2015-04-20 2.4 Location of Testing 1) Jiangsu Zeversolar New Energy Co., Ltd. Building 9, No.198 Xiangyang Road, 215011 Suzhou, PEOPLE'S REPUBLIC OF CHINA 2) Nanjing CQC - Trusted Testing Technology Co., Ltd. No.99,Wenlan Road, Xianlin University Zone, Xianlin Street, Qixia District, NanJing, China 2.5 Points of Non-compliance or Exceptions of the Test Procedure None 3 Test Results 3.1 Positive Test Results F.3 Requirements for the test report for power generation units (DE-AR-N 4105) Extract from test report for unit certificate Determination of electrical properties Type of system Generation unit manufacturer Grid-connected inverter for P system Jiangsu Zeversolar New Energy Co.,Ltd. Address: Building 9, No.198, Xiangyang Road, 215011, No. 70.409.15.042.02-00 Manufacturer s data Type of system: Active power (nominal power at reference conditions): Grid-connected inverter for P system 30kW Page: 3 of 10 TÜ SÜ D Certification and Testing

Suzhou, PEOPLE'S REPUBLIC OF CHINA Rated voltage: Period of measurement: From 2015-02-10 to 2015-04-20 3/N/PE~ 400 Active power P Emax 33kW Reactive power reference (@0,91Un) Active power P/P Emax [%] Max. possible cosφ under-excited Max. possible cosφ over-excited 10 20 30 40 50 60 70 80 90 100 0,849 0,848 0,847 0,847 0,847 0,848 0,848 0,886** 1,000** N/A* 0,858 0,857 0,854 0,853 0,852 0,852 0,851 0,884** 1,000** N/A* Remark: * : The max. current is limited by software to 48 A, the apparent power and active power are limited accordingly when test at fixed grid voltage(0,91un). S limited=p limited=48 x 209,3 x 3 30000W/A So the P Emax can not reached when test at 0,91Un. ** : Due to apparent power is limited to S Emax, the active power is reduced accordingly when adjust cos φ. It is therefore not achieved to default cos φ at points 80% and 90% P/P Emax. The max. possible cos φ is recorded accordingly. Reactive power reference (@Un) Active power P/P Emax [%] Max. possible cosφ under-excited Max. possible cosφ over-excited 10 20 30 40 50 60 70 80 90 100 0,848 0,848 0,847 0,847 0,847 0,848 0,848 0,849 0,905* 1,000* 0,849 0,851 0,851 0,850 0,850 0,850 0,850 0,849 0,904* 1,000* Reactive power reference (@1,09Un) Active power P/P Emax [%] Max. possible cosφ under-excited Max. possible cosφ over-excited 10 20 30 40 50 60 70 80 90 100 0,843 0,848 0,848 0,848 0,848 0,848 0,848 0,850 0,905* 1,000* 0,833 0,845 0,847 0,848 0,848 0,848 0,848 0,848 0,904* 1,000* * : Due to apparent power is limited to S Emax, the active power is reduced accordingly when adjust cos φ. It is therefore not achieved to default cos φ at points 90% and 100% P/P Emax. The max. possible cos φ is recorded accordingly. Page: 4 of 10 TÜ SÜ D Certification and Testing

Compliance of required displacement factor cosφ Default in system control 0,900 O 0,920 O 0,940 O 0,960 O 0,980 O 1,000 0,980 U 0,960 U 0,940 U 0,920 U 0,900 U Measured value at PGU terminals 0,899 0,919 0,938 0,960 0,979 1,000 0,981 0,962 0,940 0,921 0,901 Reactive power transfer function Standard-cosφ-(P)-characteristic Active power P/P Emax [%] 10 20 30 40 50 60 70 80 90 100 cosφ 0,990 0,996 0,997 0,998 0,999 0,979 0,960 0,939 0,921 -* Conform to Standard- cosφ-(p)-characteristic Remark: * :The maximum apparent power of the inverter is limited to S Emax. If setting cos φ 1, the maximum active power is reduced accordingly. The active power 100% P/P Emax is therefore only achieved when cos φ = 1. Switching actions Making operation without default (of primary energy carrier) k i 0,13 Worst case at switch over of generator sections* k i - Making operation at reference conditions (of primary energy carrier) k i 1,01 Breaking operation at nominal power k i 1,01 Worst-case value of all switching operations k imax 1,01 Remark: * Not applicable for P system Flicker Angle of network impedance ψ k: 32 1) 50 70 85 Coefficient of system flicker c ψ: 3,61 - - - Remark: 1) R A = 0,24 Ω; X A = j 0,15 Ω at 50 Hz network impedance used for most unfavorable condition which is approximately 32 flicker angle. Page: 5 of 10 TÜ SÜ D Certification and Testing

Harmonics Active 0 10 20 30 40 50 60 70 80 90 100 power P/Pn[%] Ordinal I [%] I [%] I [%] I [%] I [%] I [%] I [%] I [%] I [%] I [%] I [%] number 2-0,14 0,18 0,18 0,20 0,28 0,27 0,33 0,31 0,28 0,31 3-0,05 0,08 0,13 0,19 0,25 0,37 0,49 0,49 0,84 1,07 4-0,03 0,04 0,05 0,07 0,06 0,10 0,08 0,06 0,09 0,09 5-0,24 0,20 0,26 0,28 0,28 0,28 0,27 0,28 0,26 0,25 6-0,02 0,03 0,04 0,05 0,07 0,06 0,07 0,04 0,05 0,05 7-0,14 0,13 0,17 0,18 0,18 0,19 0,19 0,19 0,19 0,18 8-0,08 0,11 0,11 0,11 0,11 0,11 0,13 0,11 0,11 0,11 9-0,01 0,02 0,03 0,03 0,03 0,04 0,04 0,03 0,04 0,04 10-0,08 0,09 0,10 0,09 0,10 0,11 0,12 0,10 0,11 0,12 11-0,15 0,05 0,11 0,14 0,16 0,17 0,17 0,18 0,19 0,18 12-0,01 0,02 0,03 0,03 0,04 0,03 0,04 0,04 0,03 0,03 13-0,10 0,08 0,11 0,15 0,17 0,18 0,19 0,20 0,21 0,20 14-0,02 0,02 0,02 0,03 0,03 0,03 0,03 0,04 0,03 0,03 15-0,01 0,01 0,02 0,02 0,02 0,03 0,02 0,02 0,03 0,03 16-0,05 0,04 0,05 0,05 0,05 0,05 0,05 0,05 0,05 0,05 17-0,04 0,08 0,09 0,11 0,13 0,16 0,17 0,17 0,19 0,18 18-0,01 0,02 0,02 0,02 0,03 0,03 0,03 0,04 0,03 0,03 19-0,03 0,07 0,09 0,10 0,13 0,16 0,17 0,17 0,19 0,19 20-0,03 0,02 0,03 0,03 0,03 0,04 0,04 0,04 0,04 0,04 21-0,01 0,01 0,02 0,02 0,02 0,02 0,02 0,02 0,02 0,02 22-0,02 0,02 0,02 0,02 0,02 0,02 0,03 0,03 0,02 0,02 23-0,02 0,03 0,07 0,08 0,10 0,12 0,13 0,14 0,16 0,16 24-0,01 0,01 0,01 0,01 0,02 0,02 0,03 0,03 0,02 0,02 25-0,03 0,03 0,06 0,07 0,09 0,12 0,14 0,14 0,17 0,17 26-0,01 0,01 0,01 0,01 0,02 0,02 0,02 0,02 0,02 0,02 27-0,01 0,01 0,01 0,01 0,02 0,02 0,02 0,02 0,02 0,02 28-0,01 0,01 0,01 0,01 0,01 0,02 0,02 0,02 0,02 0,02 29-0,03 0,03 0,04 0,05 0,07 0,09 0,11 0,10 0,13 0,13 30-0,01 0,01 0,01 0,01 0,01 0,02 0,02 0,02 0,02 0,02 31-0,05 0,03 0,03 0,04 0,06 0,08 0,10 0,10 0,13 0,13 32-0,01 0,01 0,01 0,02 0,02 0,02 0,02 0,02 0,02 0,02 33-0,01 0,01 0,01 0,01 0,01 0,02 0,02 0,02 0,02 0,02 34-0,01 0,01 0,01 0,02 0,02 0,02 0,02 0,02 0,02 0,02 35-0,05 0,04 0,02 0,02 0,04 0,05 0,07 0,06 0,09 0,10 36-0,01 0,01 0,01 0,01 0,01 0,01 0,02 0,01 0,02 0,02 37-0,04 0,04 0,03 0,02 0,03 0,05 0,06 0,06 0,08 0,09 38-0,01 0,01 0,01 0,01 0,01 0,02 0,02 0,02 0,02 0,02 39-0,01 0,01 0,01 0,01 0,01 0,02 0,01 0,01 0,02 0,02 40-0,01 0,01 0,01 0,01 0,01 0,01 0,02 0,01 0,01 0,01 Page: 6 of 10 TÜ SÜ D Certification and Testing

Subharmonics Active 0 10 20 30 40 50 60 70 80 90 100 power P/Pn[%] Frequency I [%] I [%] I [%] I [%] I [%] I [%] I [%] I [%] I [%] I [%] I [%] [Hz] 75-0,09 0,12 0,26 0,29 0,27 0,38 0,33 0,28 0,35 0,31 125-0,06 0,08 0,15 0,17 0,16 0,26 0,21 0,16 0,23 0,23 175-0,06 0,12 0,18 0,21 0,18 0,24 0,16 0,19 0,19 0,18 225-0,06 0,13 0,22 0,20 0,19 0,17 0,20 0,14 0,14 0,15 275-0,05 0,08 0,20 0,20 0,20 0,18 0,16 0,17 0,14 0,13 325-0,05 0,07 0,17 0,17 0,15 0,17 0,16 0,11 0,13 0,13 375-0,03 0,04 0,08 0,08 0,08 0,11 0,10 0,06 0,10 0,10 425-0,03 0,03 0,07 0,07 0,07 0,09 0,09 0,05 0,09 0,09 475-0,05 0,05 0,10 0,13 0,14 0,15 0,14 0,11 0,11 0,11 525-0,05 0,05 0,10 0,13 0,13 0,13 0,13 0,14 0,10 0,09 575-0,03 0,05 0,08 0,12 0,14 0,14 0,14 0,14 0,11 0,09 625-0,03 0,05 0,09 0,13 0,13 0,14 0,13 0,13 0,11 0,10 675-0,02 0,03 0,05 0,05 0,05 0,07 0,06 0,05 0,06 0,06 725-0,02 0,02 0,04 0,05 0,04 0,06 0,06 0,05 0,06 0,06 775-0,02 0,05 0,05 0,07 0,09 0,11 0,11 0,10 0,10 0,08 825-0,02 0,05 0,05 0,07 0,10 0,11 0,11 0,12 0,09 0,08 875-0,02 0,05 0,04 0,06 0,10 0,11 0,11 0,12 0,10 0,08 925-0,02 0,05 0,05 0,07 0,10 0,12 0,12 0,12 0,11 0,09 975-0,02 0,03 0,03 0,04 0,04 0,06 0,05 0,04 0,05 0,05 1025-0,02 0,02 0,03 0,04 0,04 0,05 0,05 0,04 0,05 0,05 1075-0,02 0,02 0,04 0,04 0,06 0,08 0,09 0,08 0,09 0,07 1125-0,02 0,02 0,04 0,04 0,06 0,08 0,10 0,09 0,09 0,07 1175-0,03 0,02 0,04 0,03 0,06 0,08 0,09 0,09 0,09 0,07 1225-0,03 0,03 0,04 0,04 0,06 0,09 0,11 0,09 0,10 0,09 1275-0,02 0,02 0,03 0,03 0,03 0,05 0,04 0,03 0,05 0,04 1325-0,02 0,02 0,03 0,03 0,03 0,04 0,04 0,03 0,04 0,04 1375-0,02 0,02 0,03 0,03 0,03 0,06 0,06 0,06 0,07 0,07 1425-0,02 0,02 0,03 0,03 0,03 0,05 0,07 0,06 0,07 0,06 1475-0,02 0,02 0,03 0,03 0,03 0,05 0,06 0,06 0,07 0,06 1525-0,02 0,02 0,03 0,03 0,03 0,05 0,07 0,06 0,08 0,08 1575-0,01 0,02 0,02 0,03 0,03 0,03 0,03 0,03 0,04 0,04 1625-0,01 0,02 0,02 0,03 0,03 0,03 0,03 0,02 0,03 0,04 1675-0,02 0,03 0,03 0,03 0,03 0,03 0,04 0,03 0,05 0,05 1725-0,02 0,03 0,03 0,02 0,02 0,03 0,04 0,04 0,05 0,05 1775-0,01 0,03 0,03 0,03 0,03 0,03 0,04 0,03 0,05 0,04 1825-0,02 0,04 0,03 0,03 0,02 0,03 0,04 0,03 0,05 0,05 1875-0,01 0,01 0,02 0,02 0,02 0,03 0,03 0,02 0,03 0,03 1925-0,01 0,01 0,02 0,02 0,02 0,03 0,02 0,02 0,03 0,03 1975-0,02 0,03 0,03 0,03 0,02 0,03 0,03 0,02 0,04 0,04 Page: 7 of 10 TÜ SÜ D Certification and Testing

Higher frequencies Active power 0 10 20 30 40 50 60 70 80 90 100 P/Pn[%] Frequency I [%] I [%] I [%] I [%] I [%] I [%] I [%] I [%] I [%] I [%] I [%] [khz] 2.1-0,01 0,01 0,01 0,01 0,01 0,01 0,01 0,01 0,02 0,02 2.3-0,01 0,01 0,01 0,01 0,01 0,01 0,01 0,01 0,01 0,01 2.5-0,01 0,01 0,01 0,01 0,01 0,01 0,01 0,01 0,01 0,01 2.7-0,01 0,01 0,01 0,01 0,01 0,01 0,01 0,01 0,01 0,01 2.9-0,01 0,01 0,01 0,01 0,01 0,01 0,01 0,01 0,01 0,01 3.1-0,01 0,01 0,01 0,01 0,01 0,01 0,01 0,01 0,01 0,01 3.3-0,01 0,01 0,01 0,01 0,01 0,01 0,01 0,01 0,01 0,01 3.5-0,01 0,01 0,01 0,01 0,01 0,01 0,01 0,01 0,01 0,01 3.7-0,01 0,01 0,01 0,01 0,01 0,01 0,01 0,01 0,01 0,01 3.9-0,01 0,01 0,01 0,01 0,01 0,01 0,01 0,01 0,01 0,01 4.1-0,01 0,02 0,02 0,02 0,02 0,02 0,02 0,02 0,02 0,03 4.3-0,01 0,01 0,01 0,01 0,01 0,01 0,01 0,01 0,01 0,01 4.5-0,01 0,01 0,01 0,01 0,01 0,01 0,01 0,01 0,01 0,01 4.7-0,01 0,01 0,01 0,01 0,01 0,01 0,01 0,01 0,01 0,01 4.9-0,01 0,01 0,01 0,01 0,01 0,01 0,01 0,01 0,01 0,01 5.1-0,01 0,01 0,01 0,01 0,01 0,01 0,01 0,01 0,01 0,01 5.3-0,01 0,01 0,01 0,01 0,01 0,01 0,01 0,01 0,01 0,01 5.5-0,01 0,01 0,01 0,01 0,01 0,01 0,01 0,01 0,01 0,01 5.7-0,01 0,01 0,01 0,01 0,01 0,01 0,01 0,01 0,01 0,01 5.9-0,01 0,01 0,01 0,01 0,01 0,01 0,01 0,01 0,01 0,01 6.1-0,01 0,01 0,01 0,01 0,01 0,01 0,01 0,01 0,01 0,01 6.3-0,01 0,01 0,01 0,01 0,01 0,01 0,01 0,01 0,01 0,01 6.5-0,01 0,01 0,01 0,01 0,01 0,01 0,01 0,01 0,01 0,01 6.7-0,01 0,01 0,01 0,01 0,01 0,01 0,01 0,01 0,01 0,01 6.9-0,01 0,01 0,01 0,01 0,01 0,01 0,01 0,01 0,01 0,01 7.1-0,01 0,01 0,01 0,01 0,01 0,01 0,01 0,01 0,01 0,01 7.3-0,01 0,01 0,01 0,01 0,01 0,01 0,01 0,01 0,01 0,01 7.5-0,01 0,01 0,01 0,01 0,01 0,01 0,01 0,01 0,01 0,01 7.7-0,01 0,01 0,01 0,01 0,01 0,01 0,01 0,01 0,01 0,01 7.9-0,01 0,01 0,01 0,01 0,01 0,01 0,01 0,01 0,01 0,01 8.1-0,01 0,01 0,01 0,01 0,01 0,01 0,01 0,01 0,01 0,01 8.3-0,01 0,01 0,01 0,01 0,01 0,01 0,01 0,01 0,01 0,01 8.5-0,01 0,01 0,01 0,01 0,01 0,01 0,01 0,01 0,01 0,01 8.7-0,01 0,01 0,01 0,01 0,01 0,01 0,01 0,01 0,01 0,01 8.9-0,01 0,01 0,01 0,01 0,01 0,01 0,01 0,01 0,01 0,01 Remark: The harmonic values are maximum values from all phases. Page: 8 of 10 TÜ SÜ D Certification and Testing

F.4 Requirement for the test report for the NS protection (DE-AR-N 4105) Extract from test report for NS protection Determination of electrical properties NS protection as central NS protection Type of NS system Software version: Manufacturer: No. 70.409.15.042.02-00 Other Manufacturer s data Measuring period: Protection function From XXXX-XX-XX to XXXX-XX-XX Control value Release value Tripping time NS protection a oltage drop protection U < 0,8 * U n U n ms Rise-in-voltage protection U > 1,1 * U n U n ms Rise-in-voltage protection U >> 1,15 * U n U n ms Frequency decrease protection f < 47,5 Hz Hz ms Frequency increase protection f > 51,5 Hz Hz ms Remark: a : The tripping time comprises the period before limit violation U/f until tripping signal to interface switch. During planning of power generation system the proper time of interface switch shall be added to the highest value of time determined above. The break time (sum of tripping time NS protection plus proper time of interface switch) shall not exceed 200 ms. NS protection as integrated NS protection Remark: SEmax > 30kA, an external suitable certified central NS protection device must be installed at the central meter panel, in addition to the central NS protection, PGU is integrated with grid protection functions as below. Type of NS system Software version: Manufacturer: In addtion to the central NS protection required, PGU is integrated with grid protection functions as below Other Manufacturer s data 1.00 Assigned to PGU type Zeverlution Pro 33K Jiangsu Zeversolar New Energy Co.,Ltd. Integrated interface switch Type of Switching equipment 1 Relay Address: Building 9, No.198, Xiangyang Road, 215011, Suzhou, PEOPLE'S REPUBLIC OF CHINA Type of Switching equipment 2 Relay Measuring period: From 2015-02-10 to 2015-04-20 Protection function Setting value Tripping value c Break time a oltage drop protection U < 0,8 * U n 318,2/185,2 140,0 ms Page: 9 of 10 TÜ SÜ D Certification and Testing