PRODUCT DATA SHEET CamSafe 3 & CamSafe 3 WM

Similar documents
A CLEAN AIR WORLD. Rigid, gas tight, shock and vibration resistant. Operating pressure guaranteed to ± 8000 Pa. Functional design, userfriendly

Splash-proof Terminal HEPA Filter

FILTER MODULES FILTER MODULES APPLICATIONS

HEPA Filter System with Scanner, Type SCFhightec Triple S

Panel Finedust/HEPA Filter

BioMAX. Koch Filter Corporation. A Complete Line of HEPA Filters for Hospital, Commercial and Industrial Applications

Duct filter units. Duct HEPA filter units AKF

Compact Finedust / HEPA Filter

PLENUM WITH ABSOLUTE FILTER HOLDER FOR SUPPLY GRILLES

Centrifugal fan with highly efficient EC drive motor

SECTION HVAC AIR CLEANING DEVICES

PerfectPleat. PerfectPleat M8 ULTRA. PerfectPleat. Better Air is Our Business. 4" Extended Surface Pleated Filters. DuraFlex - AAF s Patented Media

Leadership in Filtration. MANN+HUMMEL Fuel Filters

Particle Filter Box FKU

ALTITUDE CONTROL VALVES FOR ONE WAY FLOW

Mobile recleanable HEPA filter units for a flow of m 3 / h

Type MFI COMPACT CONSTRUCTION FOR LARGE VOLUME FLOW RATES

Design Makes All The Difference...

COMBINATION PRESSURE REDUCING AND SOLENOID SHUTOFF CONTROL VALVES 2.01 COMBINATION RESSURE REDUCING AND SOLENOID SHUTOFF CONTROL VALVE

AstroCel. Better Air is Our Business ss. High Efficiency Particulate Air Filters (HEPA) Ultra Low Penetration Air Filters (ULPA)

Maximum Protection in Filter Systems CGF/CGG. GEA Ceiling Air Outlets Data & Facts. GEA Heat Exchangers / GEA Air Treatment

U X Y W L. Gear wheels. Linkage. In option: Stainless steel AISI 304L , AISI 316L or painted steel (standard RAL)

MODULAR BAGHOUSE DUST COLLECTORS POWERED BY

Air Handling Units RM-/RL-Line. AHU Casing Characteristics, Design Details For Outdoor Installation And Increased Hygiene Requirements

HCD-135. Industrial Control Damper. Application and Design. Ratings (see page 2 and 3 for specific limitations) Standard Construction.

General Specifications

Dura Water Wafer Butterfly Valve

P&G MANUFACTURING INC.

VOLU-probe/SS. Stainless Steel Pitot Airflow Traverse Probes

Registers for spiral ducts

Blower Specifications

FOR GAGE UNIT INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS

Air distribution product

Energy Recovery Laboratory Exhaust

SOLENOID CONTROL VALVE

Introduction to Johnson Controls Dampers

PRESSURE RELIEF / SURGE ANTICIPATOR CONTROL VALVE

TH Series UL 900 Class 1, Factory Mutual Approved, Truly Separatorless Filter Modules

PRESSURE REDUCING CONTROL VALVES

FlowAir CATALOG.

The reference in sandblasting. DCM\DCM 3000 a DCM to series.

COMPETENCE BROCHURE Filter Media DELBAG HEPA Filter. Fresh Air Freed of Floating Materials

Airpocket Select Ultrasonically-sealed

PRESSURE RELIEF / SUSTAINING CONTROL VALVES

External Dimensions (mm) Internal Dimension (mm) Material. Side Panel Pre-filter Main Filter Air Speed Noise Glass Door

Process Inline Filter Protective filter PLF2-9HF

FLOAT CONTROL VALVES

Spark arrestor type C

CLAIRE TOTAL SAFETY CABINET TYPE B2 Safe for chemicals due to Total Exhaust

PFA LINED BALL VALVES Installation, Operation and Maintenance Manual

V. Aa. Gram A/S

GloveFAST Cyto/Aseptic. Isolators PROTECTION, SAFETY, RELIABILITY. AND MORE.

Low Pressure Filters. Low Pressure Filters LOW PRESSURE FILTERS

Puri-Drall PDK. Puri-Clean PCK. Puri-Inlet PEK. HEPA filter air outlet with pull-down outlet element

Particle Filter Box Model FKF

Diaphragm pressure gauge, flush For sanitary applications, NS 100 Model PG43SA-D, with integrated diaphragm element monitoring

For installation into ductwork

RHF hightec RH13 / H Mobile recleanable filter unit

Small centrifugal fans made of plastic

FilterMax F. Modular dust collector with integrated pre-separator. Models

Corrosion Control for Control Rooms & Process Control Environments AIRBORNE PARTICULATE AND GASEOUS CONTAMINANT SOLUTIONS

2.- HANDLING OF VALVES BEFORE ASSEMBLY 3.- FITTING THE VALVE TO THE REST OF THE ASSEMBLY 5.- PERIODICAL INSPECTION OF THE VALVE AND MAINTENANCE

DSA HIGH EFFICIENCY DROPLET SEPARATOR DROPLET SEPARATOR DSA. With heated vanes

GloveFAST Cyto Pharma GloveFAST Cyto Aseptic Isolators PROTECTION, SAFETY, RELIABILITY AND MORE.

Energy Recovery Laboratory Exhaust

AIR ZONE INTERNATIONAL MIXED-FLOW AIR COLUMN UNIT

This innovation places FluoroSeal Plug Valves at the leading edge of technology in the industrial valve market.

PISTON DIVERTER VALVES

FILTRATION TECHNOLOGY PHARMACEUTICAL, NUTRACEUTICAL, & COSMETIC INDUSTRIES

FilterMax DF. Modular dust multi purpose collector. Models

INSTALLATION, OPERATION & MAINTENANCE MANUAL Description Handling Installation Actuators...

Ducting & Ventilation Components

WCV Series Full Pattern Wafer Check Valves 2 TO 8 PVC AND CVPC

Protector Glove Boxes.

V. Aa. Gram A/S

FilterMax DF. Modular dust multi purpose collector. Models

MCF BALL VALVES OVERVIEW

Crankcase Ventilation Manager (CVM) Installation Instructions

EDELSTAHL. Kämmer Series Aseptic and Sanitary Valves

TH Series UL 900 Class 1, Factory Mutual Approved, Truly Separatorless Filter Modules

Installation, Operation & Service Manual. PPL Bag Filter Housings. Table of Contents Page No. Eaton Filtration, LLC

HCD-230 Industrial Control Damper

FF Series Drawer Magnet

PRODUCT BROCHURE Universal duct air filter DELBAG MultiClean. One system, many solutions

MODULATING FLOAT CONTROL VALVE

Downflo Systems. Containment. With Triple-Sealed Bag-In/Bag-Out for filters and hopper discharge

Installation manual. Intake system and ventilation. Industrial engines DC09, DC13, DC16 OC16. 01:02 Issue 10 en-gb. Scania CV AB 2018, Sweden

ID & IP SERIES IN-LINE DISC AND PISTON VALVES

American Safe Room, Inc. Installation and Operation Manual for the ASR-101-BV 7-Bar Double Acting Automatic Blast Valve

Air Handling Units. Geniox. Accessories

SITRANS P measuring instruments for pressure

2/2 or 3/2-way Solenoid Valve, with pivoted armature and isolating diaphragm

Process Multi-Rheo Filter PMRF

IN-LINE DISC & PISTON VALVES

Installation and Operation Manual for a Solar System with KPW Collectors

COVER EQUIPMENT. VAREC BIOGAS 400W Series EMERGENCY RELIEF MANHOLE COVERS

PNEUMATICALLY ACTUATED 2-WAY

INSTALLATION AND OPERATING INSTRUCTIONS

Excelair. Every filter is created to perfection!

LEDGELESS VERTICAL CARTRIDGE DUST COLLECTOR

Transcription:

PRODUCT DATA SHEET CamSafe 3 & CamSafe 3 WM Camsafe 3 and Camsafe 3 Wall Mounted CamSafe 3 and CamSafe WM (WallMounted) are filter housings that can be used to supply or exhaust air. They are safe change filter housing. Indeed, the filter can be changed without breaking the containment thanks to the Bag In Bag Out (BIBO) process. This process is required when the air might be contaminated (particles, microorganisms, gases). The CamSafe 3 and CamSafe WallMounted are designed to be used within LifeScience (Pharmaceutical, Biotechnology), Healthcare (Hospital), Biological Safety Laboratory, Animal facilities. The CamSafe WM version is suitable for API (Active Pharmaceutical Ingredient) purposes. The design allows to have access to the filtration equipment from the room. The advantage is to remove API as close as possible to their emission points, avoiding long stretches of contaminated pipeline. In addition to our CamSafe Family, the CamSafe 3 and CamSafe WM are equipped with a clamping device which is positioned outside the airflow, so a reliable in-situ scanning can be performed. Moreover, our Tech Center has developed a new probe (patented) to enhance significantly the reliability of the leak detection. Finally, the system to handle the probe is working with a Magnetic Drive Coupling ensuring a long-lasting tightness of the housing. V4 01.06.2017 www.camfil.com

CONTENT TECHNICAL DATA... 3 FILTER BANK CONFIGURATION MODULE MODEL CONFIGURATION... 4 MODULE DIMENSIONS... 5 MODULE WEIGHT... 5 BANK DIMENSIONS... 6 EXAMPLE... 7 Configuration... 7 Dimensions... 7 COLLECTORS FLANGE DIMENSIONS... 7 WALL MOUNTED CONFIGURATION CS3 WALL MOUNTED - HEIGHT... 9 CS3 WALL MOUNTED - DEPTH AND WIDTH... 9 EXAMPLE... 10 WALL THICKNESS AND CUT OUT... 11 Frontal Installation... 11 Behind Wall Installation... 11 Wall Cut-out Detail... 11 SHROUD MODULE... 11 Overview... 11 Dimensions... 11 ACCESSORIES KIT DETAILS... 12 Magnehelic Kit - 0 to 750 Pa... 12 Safe change plastic bag... 12 Mounting Kit... 12 Leak tight test device DSP-3... 13 www.camfil.com 2

TECHNICAL DATA Construction 2 mm steel airtight welded Painted version Primer layer and Epoxy power coated RAL 9010 Filter mounting Spring loaded filter clamping, with two security functions: clamping is not possible if the filter is not correctly positioned and closing the door can t be done if the filter is not clamped Connection Rectangular connection flange with fastening hole pattern Pressure ports Quick connector for Ø 8 mm tube. Upstream and downstream locations provided. Camfil pressure gauges can be ordered separately. Performances Qualified at +/- 6000 Pa: - Class 3 - ISO 10648-2 - Class L1 - EN1886 - Class D - EN12237 - Class C - Eurovent 2/2 Scan Automated scan: Camfil motion control box with 220V power input Manual scan: Camfil manual turning handle Mixing Chamber The purpose of the mixing chamber is to inject and harmonize the distribution of the aerosol on the upstream side of the filter Accessories included - Gasket seat test - DIN 1946-4 with DIN quick coupling (Test equipment can be ordered separately, DIN Safety coupling M5- ISO 4414) - Door window to check if safety bag is installed - All components are explosive atmosphere compliant (optional) Accessories not included - Safe change bag with integrated o-ring sealable - Gasket and bolting - Pressure test kit - Factory mounting full or partial, individual factory tests with test report Outdoor Installation Stainless steel should be used for outdoor installation. Painted version is not suitable for this application. www.camfil.com 3

MODULE MODEL CONFIGURATION 1. PRODUCT CamSafe 3 (CS3) 2. MODEL SIZE FILTER SIZE 305 305 x 610 610 610 x 610 762 762 x 610 3. MODEL STAGE PREFILTER H: 50 mm FILTER H: 292 mm F 0 1 PF +F 1 1 F + F 0 2 PF + F + F 1 2 4. MATERIAL Painted RAL 9010 Stainless Steel - 304 L Stainless Steel - 316 L Single modules Combinations 5. BANK 1,2,3,4,5,6 6. COLLECTORS: NC NO COLLECTOR INLET 1 TOP LEFT SIDE 2 TOP CENTRAL 3 TOP RIGHT SIDE OUTLET 4 BOTTOM LEFT SIDE 5 BOTTOM CENTRAL 6 BOTTOM RIGHT SIDE www.camfil.com 4

MODULE DIMENSIONS FILTER FILTER + PREFILTER MIXING CHAMBER TOP VIEW - 610 FRONT VIEW TOP VIEW - 305 MODULE WEIGHT DIMENSION TYPE WEIGHT in kg 305x610 FILTER 50 FILTER + PREFILTER 72 610x610 FILTER 56 FILTER + PREFILTER 81 www.camfil.com 5

BANK DIMENSIONS Modules List Collector Sup. Mixing Chamber* F Module Collector Inf. Gaskets (x3) Collector Sup. Mixing Chamber* PF + F Module Collector Inf. Gaskets (x3) Collector Sup. Mixing Chamber* F + F Modules Collector Inf. Gaskets (x4) Collector Sup. Mixing Chamber* PF + F + F Modules Collector Inf. Gaskets (x4) H (mm) 1 2 3 4 5 6 Total H (mm) Total H (mm) 445 Total H (mm) Total H (mm) Total H (mm) 2131 2131 2205 2355 2450 400 400 400 400 400 400 650 650 650 650 650 650 1728* 1728* 1802* 595 1952* 690 2047* 9 9 9 9 9 9 445 2381 2381 2455 2605 2 400 400 400 400 400 400 900 900 900 900 900 900 1978* 1978* 2052* 595 2202* 690 2297* 9 9 9 9 9 9 445 2784 2784 2858 3008 3103 400 400 400 400 400 400 1300 1300 1300 1300 1300 1300 2381* 2381* 2455* 595 2605* 690 2* 12 12 12 12 12 12 445 3034 3034 3108 3258 3353 400 400 400 400 400 400 1550 1550 1550 1550 1550 1550 2631* 2631* 2705* 595 2855* 690 2950* 12 12 12 12 12 12 Total Width (flange to flange) 880 1685 2492 3297 4256 4987 800 825 800 825 800 825 800 825 Total 2684 2281* 2934 2531* 3337 2934* 3587 3184* All dimensions are in mm Total Height without mixing chamber and a gasket less with the *, total height in bold. www.camfil.com 6

EXAMPLE Configuration CS3 designates the Camfil CamSafe 3 product line CS3 610 designates the filter size CS3 610 PF+F designates the filter stages CS3 610 PF+F PAINTED designates the material CS3 610 PF+F PAINTED 2 designates the bank number CS3 610 PF+F PAINTED 2 1/6 designates the collector s inlet/outlet positions 2 Modules List H (mm) Total Collector Sup. Mixing Chamber* 400 2381 PF + F Module 900 Collector Inf. Gaskets (x3) 9 1978* Total Width 1685 CS3 610 PF+F PAINTED 2 1/6 Illustration Dimensions from table Dimensions CS3 610 PF+F PAINTED 2 1/6 Dimensions www.camfil.com 7

762 610 305 COLLECTORS FLANGE DIMENSIONS 1 2 3 4 5 6 - - - www.camfil.com 8

Transition Outlet Mixing Chamber Main body Damper Transition Inlet CS3 WALL MOUNTED - HEIGHT Illustration Height Illustration D Optional Height 385 Illustration F+F and PF+F+F are 2 modules with a gasket in between Height 650 900 1300 (+ Gasket x1) 1550 (+ Gasket x1) Optional Illustration MC Can be used with double filter stage Height 400 Can be used twice Illustration Height 916 CS3 WALL MOUNTED - DEPTH AND WIDTH 305 610 The configuration has no influence on the width www.camfil.com 9

EXAMPLE Transition Outlet + Damper + CS 3 Module + Mixing chamber +Transition Inlet Transition Outlet Gasket Damper Gasket CS 3 Module Mixing Chamber Gasket Gasket Transition Inlet www.camfil.com 10

WALL THICKNESS AND CUT OUT Frontal Installation Behind Wall Installation 200 mm max 200 mm max 2 different brackets holder position for adjustment Screw connection Wall Cut-out Detail a b c Value mm (For example above) Details General case with 5 mm clearance all around Frontal Installation a 976 Total W + 2x5 b 2310 Total H-427 + 2x5 c 120 125-5 Behind Wall Installation a 1044 976+68 mm clearance b 2378 2310+68 mm clearance c 83 Sealing all around the flange against the wall SHROUD MODULE Overview Particule Injection Connection holes Dimensions www.camfil.com 11

ACCESSORIES KIT DETAILS Magnehelic Kit - 0 to 750 Pa Range: Gasket: Wall: Tube: 0 750 Pa 4 gaskets vulcanize fiber 12-17 diam. 15x10 thickness 3mm 2 passages Layton union wall 4x6 2 m of vinyl tube 4x6 Safe change plastic bag Type: Conception: Connecting: Applications: Safe change plastic bag welded with sealed o-ring PVC thickness 20/100 frequency welded high By Ø8mm nitril oring For filter changing in contaminated airflow Mounting Kit Application: Connection: CamSafe 3 housing connecting kit with perfectly adapted repositionable adhesive gasket and bolts On rectangular pre-drilled flanges, for: CamSafe module to CamSafe module Camsafe to collectors Collectors to ventilation system Bolts: Gasket: Electrogalvanized bolting for Painted Camsafe Stainless Steel for Stainless Camsafe EPDM gasket Thickness 5mm, 4 parts gasket with repositionable adhesive www.camfil.com 12

Leak tight test device DSP-3 Pressure Range: 0-3 kpa Measurement Range: Min 6 l/h Max 60l/h Function: Suitable for testing HEPA/ULPA filters with test grooves Housing dimensions: LxWxH: 240 x 120 x 160 The Camfil seal position tester can be used to test all HEPA/ULPA filter cells for perfect seal position in any suitable duct housing, even during operation. Connection pieces on CAMFILFKB/D, FKS/D, CAMSAFE, CAMBOX and containment housings are clearly indicated with a label. For FKOP housings, connection pieces are located on the side of the interior of the housing. According to DIN 1946/sheet 4, the leakage air flow must be tested between the filter seal and housing support frame at an overpressure of 2000 Pa (200 mm water column) in the test groove. The permissible leakage air flow VL should not exceed the natural leakage air rate (penetration) of the HEPA/ULPA filter, E11 H14 as per DIN EN 1822. www.camfil.com 13