Key Installation Points. Table of Contents

Similar documents
Installation must be in Accordance with AS/NZS

INSTALLATION MANUAL. Installation Details Warranty Wolfen 122 Wall Bubbler Wolfen 90 Wall Bubbler Wolfen Hob Bubbler

Part No: Genuine Mira Accessories

THERMOSTATIC CONCENTRIC DUAL CONTROL SHOWER VALVES Installation & aftercare instructions

TOUCH-ACTIVATED URINAL FLUSHING SYSTEM SLIM STYLE PANEL - LARGE (FRONT ACCESS)

ROCA KHROMA TOILET SUITE

HANDS FREE FOOT & KNEE OPERATED TAPWARE

TOUCH-ACTIVATED DUAL FLUSH WC FLUSHING SYSTEM - FRONT ACCESS

SERIES II WALVIT + CUBE. 1.28/0.8 Gal (4.8/3 Litre)

Mira Mode Shower and Bath Fittings

ROCA THE GAP BACK TO WALL TOILET SUITE

FASHION SKIRTED TOILET FOR P & S TRAPS DUAL FLUSH OWNER S MANUAL ITM. / ART # QTA023

VIVID SLIMLINE FLOOR MOUNTED BATH MIXER PRODUCT CODE: FINISH: VS745 CHR CHROME STYLISH PREMIUM FINISH CONTEMPORARY DESIGN PHOENIX WARRANTY

THERMOSTATIC INLINE CONTROL SHOWER VALVES Installation & aftercare instructions

3.0 INSTALLATION INSTRUCTIONS. Avon 21 Self-closing taps (Push button) B0992AA Self-closing basin pillar tap

Duo water control system

Mini Twinline Sequential Shower Valves

RUSH WALL TOP ASSEMBLIES EXT D 15MM PRODUCT CODE: FINISH: RU067 MB MATTE BLACK 3/4 TURN OPERATION PREMIUM FINISHES

8000 / 10,000 / 12,000

INSTALLATION MANUAL. Installation Details Warranty Wolfen Foot Operated Pedal Valve Wolfen Foot Operated Kit with Outlet

HIDEAWAY PLUS IN-WALL CISTERN (BACK TO WALL PAN)

Installation, Care and Maintenance Instructions. Optiflush OP1 Battery and OP2 Mains Versions

flushing systems SMART CHOICES FOR HYGIENE AND WATER EFFICIENCY BUILT IN VANDAL RESISTANCE Toilet Flushing Systems Urinal Flushing Systems

MECHANICAL UNDER COUNTER 150 CONCEALED CISTERN (BTW)

DYNAFLUID 2000 STEAM & WATER MIXING VALVE INSTALLATION & OPERATING MANUAL

1901 Thermostatic Shower Mixer

Flush Valve Systems. By SCHELL.

GLOSS WALL BATH SET PRODUCT CODE: FINISH: GS783 CHR CHROME CONTEMPORARY DESIGN PHOENIX WARRANTY STYLISH PREMIUM CHROME FINISH MATCH WITH...

RUSH SHOWER/BATH DIVERTER MIXER PRODUCT CODE: FINISH: RU791 CHR CHROME CONTEMPORARY DESIGN PHOENIX WARRANTY STYLISH PREMIUM CHROME FINISH

Infrared Control Valve Installation Guide

Infrared Control Valve Installation Guide

Scale Feeder Manifold Water Filtration System Instruction Manual

OMEGA UNDER COUNTER MECHANICAL BTW 4S CONCEALED CISTERN

G SERIES - E TOUCH MIXER / TAP

Installation and Operating Instructions for Davey HM Series Pressure Systems with Pressure Switch

IRC Urinal Flush Control Valve

INSTALLATION MANUAL IMPORTANT CONSIDERATIONS TECHNICAL INFORMATION. Tools you may need

Zenith Aqua Sense Taps

DOMINIQUE MKII SEMI RECESSED vanity

MIZU QUICK CHANGE DUAL FILTER SYSTEM

APT14 Automatic Pump Trap Installation and Maintenance Instructions

Installation Instructions

List Of Product(s) Installed

TFL Gas Log Lighter (TFLGLL)

Installation, Operating, Maintenance and Safety Instructions for CW332 Pressurised water system for boats 24 volt d.c.

Airtec Snorkel Assembly Vehicle: Toyota FJ Cruiser 4.0L Petrol, 04/2011+ Part No. 011SAT0185A. Read instructions fully before commencing fitment.

Zip FlushMaster Surface mounted sensor

Installation & user guide

Figure DC03. Double check valves for medium hazard rated applications BSP screwed connections. Features

SIGMA PNEUMATIC CARE BUTTON

SEries 41 check valve installation, operation & maintenance manual

INSTALLATION MANUAL. Installation Details Warranty Wolfen Pre Rinse Sink Mixer Wolfen Compact Pre Rinse Sink Mixer

M Installation Guide. PRECISION Manifold Series. Introduction. A. Assemble Manifold Components

Dual Flow Manifold Systems Instruction Manual

PIL0478 ISSUE 01/ 07/16

Zip FlushMaster Solo Water Saver Urinal Flushing System Keeps Urinals Clean & Reduces Water Wastage

Solar Thermal. Grant Solar Pump Station Installation & Servicing Instructions

Integra / Summer Breeze

MODEL VG08001 CONTENT PACKING LIST / TOOLS NEEDED PANEL DIMENSIONS FITTINGS / TECHNICAL DATA WALL/CORNER INSTALLATION CARE AND TROUBLE SHOOTING

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS

These instructions are to be left with the user

ENWARE-ORAS SINGLE LEVER MIXER Installation and Maintenance Instructions

OMIKA. it s a personal experience. Installation Guide Wall Mounted Basin Mixer. This instruction booklet covers this model: OMI-109.

Compact Concealed Toilet Cistern with Dual flush CNC1001

Installation, Operation, and Maintenance Manual

Flue installation instructions. Air flue duct for use with ecomax and ecotec boilers. For the installer

PRODUCT MANUAL. Heavy Duty Backpack Sprayer 16L

Installation Instructions

Dual Port Manifold Water Filtration Systems Instruction Manual

GWA BATHROOMS & KITCHENS WARRANTY PERIODS

VADA - V75-S PRODUCT OVERVIEW CONSTRUCTION USAGE LIMITATIONS MOTOR WARRANTY

VR2-CC VR2-RS VR2-ES PRODUCT MANUAL

SIGMA75 PNEUMATIC CONCEALED CISTERN (BTW)

Model 6518FR. NOTE TO INSTALLER: Please leave this information with the Maintenance Department. LIMITED WARRANTY

UltraSystem Series II INSTALLATION MANUAL PARTNERED WITH

Airfield Industrial Estate Hixon Staffordshire ST18 0PF

ANTI VANDAL TAPWARE. Installation Instructions CONCEALED SPINDLE (CS) SERIES SCHOOL PATTERN (VP) SERIES TRADITIONAL/INSTITUTIONAL (IN) SERIES

INSTALLATION INSTRUCTIONS

Installation Instructions Blitz Tap Range

Maintenance Information

Installation For Service Only

HEAVY DUTY TROLLEY JACK. Operation Manual

The Da-Lite Difference.

INSTALLATION INSTRUCTIONS

PH1 AIR INTAKE EMERGENCY SHUT-OFF VALVE PULL CABLE ACTUATION.

4" 4" 4 1/4" 11" TOP VIE 3 1/8" Ø1/2" 2" 10 3/8" SIDE VIE VG05002 THE MEASUREMENTS IN INCHES ARE ROUNDED TO THE NEAREST 1/8"

Breezair TBA 550 Installation Manual

Installation Instructions Cobalt Tap Range

Installation Instructions Melba Sink Mixer

VANDAL RESISTANT FITTINGS VR105, VR125, VR145 (VR106, VR115 Export only) PRODUCT MANUAL IMPORTANT

Tools Required. Metric Wrench Set Screwdriver Set Metric Socket Set Pliers Heavy duty hydraulic Jack and Car Stands Box knife or similar Hacksaw WD40

MODEL 8682 SUREFLOW ADAPTIVE OFFSET CONTROLLER

M-8100EP. Installation Guide ENGINEERED PLASTIC MANIFOLD SERIES. Introduction. A. Assemble Manifold Components

INSTALLATION INSTRUCTIONS FOR SLIMLINE BEDPAN WASHER WITH EXPOSED ROYAL FLUSHOMETER

Technical Information & Warranty

Product and installation manual. Underfloor Heating Composite Manifold

The Ultimate Smart Grid Solution INSTRUCTION MANUAL

INSTALLATION INSTRUCTIONS TOILET. Castello & Sienna Back-to-Wall

Geberit Manufacturing, Inc Boone Drive, Michigan City, IN Phone: (800) Fax: (219)

Transcription:

Installation Guide

Key Installation Points Table of Contents All pipe sizes in this guide are internal diameter (DN) We recommend PE-X pipe NOT copper pipe Check pipes sizes For domestic installations we recommend a main feed via a DN 25mm line. Refer to Commercial pipe size guide for commercial applications Check that you have a minimum water pressure of 350kpa If there is a Pressure Vessel involved install a line strainer and an isolating ball valve at the Pressure Vessel Install a Pressure Reducing Valve only if water pressure exceeds 650kpa Use the foam packaging provided to cover the valve for acoustic insulation Lag the pipe work with acoustic lagging Flush the lines thoroughly before connecting the valve Ensure there is easy access to the valve for future maintenance and service Use the set screw on the top of the valve to adjust the f lush volume The Low Maintenance Flush Valve & Sensorf lush touch pad MUST be installed by an experienced, licensed plumber General Installation Advice Mains Pressure Flushing...4 Pipe Recommendations...5 Water Pressure & Flow...5 Valve & Touchpad Location...6 Ancillary Plumbing Fittings...6 Plumber Instructions & Guidelines Australian Standards...7 Low Maintenance Flush Valve...7 Ceiling Mounted Valve...8 Wall Mounted Valve...9 Attaching the Valve... 10 Water Supply... 11 Water Pressure & Flow... 11 Pressure Vessels... 11 Flush Pipe Layout... 12 Line Flushing... 13 Preliminary Check... 14 Touchpad Position... 14 Installing the touchpad Connecting the leads to the valve and the touchpad... 15 Sensorf lush Standard Range Stainless Steel... 16 Tile-in Touchpads... 17 Installing the Sensorf lush Corian Touchpad... 17 Commissioning the Valve & Adjusting the Flush... 20 Touchpad operation... 21 Troubleshooting... 21 Warranty conditions:... 22 2 3

General Installation Advice General Installation Advice Mains Pressure Flushing The Low Maintenance Flush Valve is a sanitary f lush valve which connects directly to the water mains. It is not designed to be connected to a cistern. It can be used with any standard wall-hung or wall faced pan and with most urinals. The valve requires a Sensorf lush touchpad to be installed for activation. Correct installation of the Low Maintenance Flush Valve and Sensorf lush touch pad will provide trouble free toilet f lushing. Plumbers should pay careful attention to pipe sizing, acoustic insulation and correct f itting of any/all ancillary plumbing f ittings. The installing plumber MUST read and follow this guide to ensure installation meets manufacturer s requirements, all relevant Australian standards and that all National Plumbing Code requirements are met. Incorrect installation of the Low Maintenance Flush Valve and/or Sensorf lush touch pad will result in the void of warranty. CONTENTS Pipe Recommendations All pipe sizes in this guide are internal diameter (DN) sizes. Refer to the Commercial Plumbing Sizing Guide for further details of pipe sizes for commercial installations. This guide can be found on our website: www.hydaf lush.com.au In domestic installations we recommend the main supply line be a minimum DN 25mm. All Low Maintenance Flush Valves should be supplied by branch line using a minimum DN 25mm pipe. We do not recommend copper pipes due to their poor acoustic qualities. If copper is used, care should be taken to ensure it is adequately sized and acoustically insulated. Hydaf lush recommends PE-X pipe materials. Do not use Outer Diameter measurements when sizing supply pipes. All recommended sizes are internal diameter sizes. Up-sizing pipe work may impact friction losses and velocity altering the performance of the system. Water Pressure & Flow A pressure vessel may be required to assist with increase in water supply to valve. The minimum flow rate required at the valve is 1.5 litres per second. This flow rate must be maintained regardless of the simultaneous maximum demand from subsequent Low Maintenance Flush Valves and other appliances on the line. We recommend valves be connected using an independent line from the mains to prevent any impact on other appliances. Pipe distance between valve and pressure vessel should be considered. 4 5

General Installation Advice Plumber Instructions & Guidelines A hydraulic engineer should be consulted for all installations of 5 or more valves or when there are complex water supply factors to consider such as multi-storey buildings, uncertain water pressure, water variances such as water quality, excessive distance from mains to the pressure, water variances such as water quality, excessive distance from mains to the valves, potential acoustic problems and heavy or uncertain demands from a system or other appliances. (Examples only Other situations should also be considered). Valve & Touchpad Location The valve can be installed either in a minimum 90mm wall cavity or in the ceiling space. The valve must be accessible to allow for future maintenance and servicing. An isolating ball valve must be installed at each Low Maintenance Flush Valve. Space required around the valve must be a minimum of 300mm. The touchpad can be installed in the traditional location on the wall behind the toilet or elsewhere in the room. Access to a secure standard 240v power outlet is required. Ancillary Plumbing Fittings The installation may require the inclusion of one or more of the following: A line strainer A pressure vessel A pressure reducing valve (If pressure exceeds 650kpa). Australian Standards The valve MUST be installed by a licensed qualified plumber. All Australian Standards for the installation of f lush valves must be met (AS/NZS 3500.2). Refer to the Warranty section of this guide for details of installation obligations. Low Maintenance Flush Valve Using the mounting screws provided, install the valve vertically in either the wall space (minimum 90mm cavity) or ceiling and with loose coupling connections on both the inlet and outlet of valve. Ensure the valve is securely fastened to a suitable stable structural support. Allow for easy access to the valve for servicing. Front or rear access panels for an in-wall installation should be a minimum of 300mm x 300mm. A minimum clearance of 300mm is required above the valve to allow access to the set screw on the top of the valve for f low adjustment and to remove the bonnet of the valve for servicing. All plumbing connection points to the valve MUST be accessible. When servicing valve piston, plumber should use Rocol Sapphire Grease. The polystyrene packaging material supplied should be placed around the valve and taped into place to provide acoustic insulation. Additional acoustic insulation around the valve is recommended in residential applications. 6 7

Plumber Instructions & Guidelines Plumber Instructions & Guidelines Ceiling Mounted Valve Wall Mounted Valve 8 9

Plumber Instructions & Guidelines Plumber Instructions & Guidelines Attaching the Valve Water Supply We recommend that all Low Maintenance Flush Valves be supplied using a minimum DN 25mm pipe. We recommend that in domestic installations the main supply line should be DN 25mm. Refer to the Commercial Plumbing Sizing Guide for further details of pipe sizes for commercial installations. This guide can be found on our website: www.hydaf lush.com.au. The Low Maintenance Flush Valve should be run off an independent line. Failure to do so may impact on other water appliances within the premises or may cause unsatisfactory operation of the valve. Limit the number of direction changes in pipe work. Supply lines to valves should be PE-X pipe. Acoustic insulation must be used for all pipework which may affect habitable rooms Water Pressure & Flow All installations require water f low of 1.5lts per second at each at each Low Maintenance Flush Valve and water pressure of between 350kpa and 650kpa. Insufficient water f low rates or water pressure outside this range may lead to malfunction of the valve. Pressure Vessels If installed correctly, a pressure vessel may assist performance in maintaining a constant supply of water to the valve. If a pressure vessel is required ensure that it is installed in compliance with the manufacturer s instructions. 10 11

Plumber Instructions & Guidelines Plumber Instructions & Guidelines Flush Pipe Layout The f lush pipe must be a minimum of DN 40mm. Geberit 56mm Silent Pipe is recommended. The f lush pipe must be a minimum of 450mm in length. If the f lush pipe is longer than 2.5m (i.e. the distance from the valve to the f lush pipe outlet) you will need to slow the water down with a pair of 45 degree bends every 1.5m. Do not allow bends of greater than 45 degrees except for the f inal connection to the pan. Line Flushing All supply lines MUST be f lushed to ensure removal of swarf and construction debris prior to connecting the valve. Failure to do so will cause the valve to malfunction and will void the warranty. To f lush the water lines after the valve has been installed you must f irst remove the piston from the valve. To do this, shut off the water supply to the valve, unscrew the white bonnet from the top of the valve, use a pair of pliers to remove the piston from inside the valve and reattach the bonnet. Open the water supply to fully f lush the lines. Once this has been done, re-install the piston and re-attach the white bonnet. Do not run f lush pipes horizontally. Flush pipes must be acoustic pipes such as Geberit Silent Pipe or acoustic lagged PE-X. 12 13

Plumber Instructions & Guidelines Plumber Instructions & Guidelines Preliminary Check Before connecting the touchpad: Be sure that all plumbing connections except the pan connection have been completed and the valve has been correctly installed. Be sure that the water supply is connected and supply lines are open. Do not connect the pan until the touchpad has been installed and the system has been commissioned. Place a large bucket under the f lush pipe prior to installing the touchpad as the valve may f lush when the touchpad is connected and powered up. Touchpad Position The touchpad may be installed in the traditional position on the wall directly behind the toilet or in another location which is convenient. The unit is supplied with a 2m lead to connect the touchpad to the valve. Extension leads are available as a spare part if required. If 2m lead supplied is not long enough, DO NOT cut lead, this will void warranty. If installing the touch pad behind the toilet, take care to ensure that the raised toilet seat does not rest on the touchpad. Standard height of f the floor is between 900mm and 1100mm. The touchpad should be positioned so that the half f lush logo is on the lef t side of the plate. In the case of the vertical lined stainless steel pad the half f lush logo should be at the top of the pad. Connecting the leads to the valve and the touchpad All our touch pads are connected to the valve in the same way. The touchpad is supplied with a 2 metre lead and a power pack. The connectors only allow for connection the correct way. Extension leads are available as a spare part. With the power of f, connect the lead to the valve by attaching the two red lugs of the lead to the metal tabs on the valve. Then thread the white plug end of the lead through the wall opening and connect it to the touchpad. Thread the power lead through the wall opening and connect it to the touchpad. Plug the power pack into the power outlet. When the power is turned on the valve may activate for a half-flush. 14 15

Installing the touchpad Installing the touchpad Sensorf lush Standard Range Stainless Steel Screw-on touchpads should be firmly screwed to a solid surface. The standard range of 110 x 70mm touch pads allow for the use of a standard electrical power outlet backing plate (C clip) to be used for attachment. Larger plates should be f irmly affixed to the wall frame. Tile-in Touchpads Tile-in touchpads must not be permanently af f ixed to the wall. We recommend Bostik 5612 Non-Skimming Butyl Mastic Sealant. This will allow future removal of the tile if necessary. Installing the Sensorf lush Corian Touchpad Step 1 - Use the mounting plate supplied as a template to position and mark the cable opening in the wall. The wall opening must be the same size as the rectangular opening in the centre of the mounting bracket, approximately 34mm x 20mm. The mounting bracket comes with a grub screw seated in a brass ring. Do not unscrew this grub screw it should be fully embedded in the brass ring. Step 2 - Cut the hole in the wall. Ensure the mounting plate is level and screw the plate to the wall using the screws supplied. Bring the leads from the power pack and valve through the hole. Wet area installations will require the touchpad to be sealed using our rubber gasket which is available as a spare part. Alternatively, the pad can be sealed using a bead of neutral cure silicone sealant. The touchpad requires an opening of 55mm x 70mm to be cut into the wall material to accommodate the circuitry on the reverse of the pad. Connect the leads as detailed above. Touch pad should be f irmly f ixed in place prior to testing. 16 17

Installing the touchpad Installing the touchpad Step 3 - Ensure the power is turned off. Connect the power and valve leads to the touchpad. These leads only allow for connection in the correct way. Step 5 - Note: The touchpad is secured to the mounting plate by the grub screw being wound out. Insert the Allen key into the hole in the base of the touchpad and unscrew the grub screw until it is f lush with the surface of the touchpad frame. The touchpad can be removed from the wall by reversing this procedure. Step 4 - Ensure that the touchpad is oriented correctly with the half f lush logo on the left side. Hook the touchpad onto the top of the mounting bracket and click the pad into position. The hole in the base of the frame will align with the grub screw in the base of the mounting plate. If the pad does not click into position check that the grub screw is fully screwed into the brass ring. WARNING: DO NOT ATTEMPT TO REMOVE OR TAMPER WITH ELECTRONICS ON REAR OF TOUCH PAD. THIS WILL DAMAGE ELECTRONICS AND VOID WARRANTY. 18 19

Low Maintenance Flush Valve Touchpad operation and Troubleshooting Commissioning the Valve & Adjusting the Flush The valve is factory set for a 6lt full flush and a 3lt half f lush at 350kpa but volumes do vary depending on the installation. Volumes can be adjusted according to the customer s needs and the WELS rating of the pan being used. Prior to connecting the pan, the volume can be measured by placing a large bucket under the f lush outlet. Activate a full f lush and use a measuring jug to measure the volume. Use a blade screwdriver to adjust the set screw located in the middle of the white bonnet of the valve. Touchpad operation The touchpad uses touch sense technology and has a built in lockout time. A gentle touch of the sensor is all that is required to activate the f lush. Once activated, the system will not re-f lush until 5 seconds after the original flush has completed. Refer to the Adjusting the f lush section above if the f lush volume needs adjusting. Troubleshooting A troubleshooting guide is available on our website at www.hydaf lush.com.au. Screw anti-clockwise to increase the f lush volume and clockwise to decrease the f lush volume. 20 21

Warranty Details Every Low Maintenance Flush Valve and touchpad is under warranty for 12 months covering parts and labour ONLY. (12 months from date of purchase) Warranty conditions: The products MUST be correctly installed including the f lushing of lines prior to connecting the valve. The valve MUST be installed by a qualified licensed plumber. The installation must meet all relevant Australian Standards (AS/NZS 3500.2). The requirements of water pressure and flow MUST be met. The warranty covers faults in the product construction, material and assembly ONLY. It does NOT cover faults due to incorrect installation practices. The warranty does not cover claims for damages or consequential loss either directly or indirectly due to the valve or touchpad. Note: Service callouts resulting from poor, faulty or incorrect installation will be billed to the original installing plumber, customer or requesting party Corian is a DuPont registered trademark for its solid surfaces. Hydaf lush 2011 Hydaf lush Customer Service: 1300 384 749 www.hydaf lush.com.au 22