BWT Infinity A DIN 20mm.972 L/s DIN 25mm L/s DIN 32mm L/s

Similar documents
UV sterilizers and spare parts

Watertreatment. Landbased Farming. Weedfilter. Catvis WATER I NTAKE R ECIRCULATION S YSTEM

Hydrosafe - Model HSFS

GENO -MX 1" - MX DN 100 backwash filter. Intended use. Scope of supply. Function. Structure

TECHNICAL DESCRIPTION

Engineered to Higher Standards

ECONOPLATE BV SERIES HOT WATER SERVICE PACKAGED HEAT EXCHANGERS WITH THERMAL STORES

TECHNICAL DESCRIPTION

EXPERTS IN ULTRAVIOLET DISINFECTION

SOLICITATION C INSTALLATION AND MAINTENANCE OF POTABLE WATER FILTRATION SYSTEMS THROUGHOUT THE STATE OF FLORIDA QUESTIONS AND ANSWER

REVISED ATM72 Auto Transfer Module

ULTRAVIOLET WATER DISINFECTION SYSTEM OPERATION & MAINTENANCE MANUAL

Expert tip: UNPARALLELED PROTECTION AND VERSATILITY UNDERGROUND IRRIGATION PROGRAMMABLE SOLENOID CONTROL UNIT 1 F. PROGRAMMABLE SOLENOID VALVE.

UVMAX Light Commercial Series Model description weight NOTES

AQUA2000 From O3PURE

1.0 F300S Ultraviolet Flood Exposure System

DIFFERENTIAL PRESSURE BATTERY CHARGERS

... PureLine PQ. Technical Specification. PureLine PQ (Disinfection) Models PQ PQ UV Chamber. Cabinet

INSTALLATION AND USER INSTRUCTIONS

GE.VO.360/325.SS+0_all

Cytotoxic Safety Cabinets ENVAIR eco safe Plus

Introduction Advantages of cooperating with Our service - our conditions Our standard central control valve

TEFEN FLOW & DOSING TECHNOLOGIES

WEDECO DLR SERIES ULTRAVIOLET WATER DISINFECTION UNIT INSTALLATION OPERATION AND MAINTENANCE MANUAL MODELS DLR-AP SERIES NO'S

WARCO CHEMAG SERIES GH FILTERS

Cooling Tower Control & Dosing Bleed, Inhibitor, Timed Biocide, ORP

AGRICULTURE HORTICULTURE GREENHOUSE

SafeFAST Classic. Class II Microbiological Safety Cabinets PROTECTION, SAFETY, RELIABILITY. AND MORE.

ARKAL FILTERS CATALOGUE

ORION. Safety Class 2 100% exhaust. ALMOST Rocket Science

Monobloc and Sectional Directional Control Valves

PURE WATER. Installation, Operation and Maintenance Manual. 3-Stage Under Counter Filtration with UV Model PWSYS-UV-3STG. Important.

UV-AIRE AIR PURIFYING SYSTEM

WL250 TOWER DRAWING AND PARTS LIST

Planning Manual Passion 300-S. Passion 300-S. Super Power Twin Power. Contents

Excel AD Electromagnetic dosing pump

INSTRUMENTATION & CONTROL

SPARE PARTS PRICE LIST SEAKEEPER SERIES

Lubrication Systems. Section 26

LK Manifold Shunt VS2

Ultraviolet Sterilization System Installation Instructions & Owner s Manual

D M S 760 C01 A A 1 1

Each pump shall be equipped with carbon/graphite vanes. A vacuum relief valve shall be incorporated into the design of the pump.

Laboratory Equipment MICROBIOLOGICAL SAFETY CABINETS ENVAIR ECO SAFE COMFORT PLUS CLASS II MICROBIOLOGICAL SAFETY CABINET.

CONTROLLERS & SPECIAL VALVES

Industrial Diesel Generator Set KD3300-F 50 Hz Fuel Consumption Optimized

Envair Lab SCS Evo Comfort+ Class II Microbiological Safety Cabinets

Heating oven with mechanical control

Model: UV-16R/24 READ THESE INSTRUCTIONS CAREFULLY AND COMPLETELY BEFORE PROCEEDING WITH THE INSTALLATION.

Dosing Pump Operational Manual

Power consumption Operation At rest Wire sizing. Auxiliary switch. EMC Low-voltage directive. Non-operating temperature range 40...

MPD Series. Medium Pressure Duplex

Fabricated Duplex Strainers

VALVES WITH UV ELECTRIC ACTUATOR

Crime-lite 2. a new and improved range of forensic light sources

Treatment Chamber. Control System

Electronic Control Valves

Each pump shall be equipped with carbon/graphite vanes. A vacuum relief valve shall be incorporated into the design of the pump.

MPD Series. Medium Pressure Duplex

DETAILED EQUIPMENT SPECIFICATION MRO-4 SERIES REVERSE OSMOSIS SYSTEMS

ROTA PULSE FLOW SENSOR Slip Insertion Paddlewheel (with inductive coil pulse output & built in op-amp circuit)

Electrical panels TECHNICAL INFORMATION 104 ELECTRICAL PANELS 105 PROTECTION OF ELECTRICAL COMPONENTS 107 ELECTRICAL PANEL ACCESSORIES 110

AGRICULTURE HORTICULTURE GREENHOUSE

Manual Kinematic Viscosity Bath Tamson TV12

Installation, Operation and Maintenance Manual

Industrial Diesel Generator Set KD2250-F 50 Hz Fuel Consumption Optimized

Indirect evaporative air conditioning 100% outside air FACTORY INSTALLATION (CW-160)

The pumps shall be Oil Free and Variable speed controlled by Pressure Transducer, PLC and inverter.

Electric FIP Type TKD ABS 3 Way Ball Valve

FLUID TRANSFER SECTION 1

GE.PK.022/020.SS+0_all

3-Way heavy duty flow control, with pressure compensated, solenoid and load sensing controlled priority flow

Marine Fuel Filtration Marine 800 Series

Angle seat valve with diaphragm actuator VZXA-...-M

INSTALLATION MANUAL & OWNER S GUIDE ULTRAVIOLET WATER TREATMENT SYSTEMS Rev. 07/16

VALVE WITH UV ACTUATOR

inlet/outlet connection flow rates filtration degrees max. working pressure

AQUA2000 ADVANCED WATER TREATMENT SYSTEMS OWNER S MANUAL INCLUDES: Restrictions. Installation. Operation. Maintenance. Changing the Filter

CALEFFI. FLOWCAL Automatic flow balancing valve with polymer cartridge. 121 series 01141/11 NA. Function

Filtration Ft-Line 34. Ck-Line 38. Cp-Series 42. FilterMax 46. Cintropur filtration 51. Cartridge housings

Electronic Temperature Sensor ETS 300

DCE 100 Series Dust Filter

INSTALLATION MANUAL & OWNER S GUIDE ULTRAVIOLET WATER TREATMENT SYSTEMS Rev. 5/10

X100 Convertible Filter Housing and Accessories

PRODUCT OVERVIEW FILTER UNITS

FILTRATION AMIAD PLASTIC FILTERS, SCREENS & DISCS

HARMSCO Filtration Products BC6 Series

LINEAR LS CHILLED / CERAMIC / BAIN MARIE

CAPACITIVE LEVEL SWITCHES. Capacitive switch catalogue HYC-CSC01 Elect. Iss. 01

Angle seat valve with piston actuator VZXA-...-K

Controller Specification Sheet

Pulsation Dampeners NEW! Wanner Engineering Inc

Heating oven with natural convection

FCU Floor Control Unit

1 HYDRAULIC POWER UNITS

Smart controls Reliable operation User friendly design Plug and play operation

Ultraviolet Lamps. Worldwide Suppliers of Specialty Lamps. Creating True Value and True Partnership

JUMO ecoline Ci Inductive conductivity and temperature sensor for general water engineering

RB15 KNAPSACK SPRAYER

WL250 TOWER DRAWING AND PARTS LIST

Transcription:

HARVESTED RAINWATER POST FILTRATION & UV DISINFECTION OPTIONS 0.50 L/s 1.40 L/s Automatic Post Filtration BWT Infinity A DIN 20mm.972 L/s DIN 25mm 1.250 L/s DIN 32mm 1.388 L/s Install one or two BWT Infinity A automatic backwash filter DIN.. Electronic timer with hour-day-week-month settings depending on the quality of the water, 90 micron anti-scale screen and associated connection module with male/male threaded unions. Each filter is capable of handling a peak demand flow rate of..l/s (Refer above) * Install isolation valves each side of the filters * Tundish to floor-waste or stormwater * 240V 10Amp Gpo within 1 meter of the installed filters above the splash Line of the tundish * Install in a plant room or under all weather sun-proof, vandal-proof, well 1

Final bag filtration 1, 5, 10, 25, 50 microns 0.50L/s 1.40 L/s Install (2) two WFC X100B-FSIX100 polypropylene bag filter housing with legs; 2 inlet / outlet ports Supply only: (4) four WFCBPONG25X01-25 micron nominal polypropylene filter bags with polytec seal (two are spares) Install on a manifold in parallel Isolation valves each of the installed bag filter housings Pressure gauges each side of the filter housings Floor waste in vicinity of housing with fall to drain housings during filter bag change (Refer to attached installation & technical data) 2

BWT UV disinfection systems where water will come in contact with humans Rainwater UV disinfection systems 0.50 L/s 1.50 L/s Install: (1) one or two BWT Bewades 80W80/11 LC 316 S/S ultra violet disinfection systems with inbuilt agitators to minimise soiling of the quartz sleeve. Technical data: Nominal connection width DIN 32mm Max vol. flow 400 J/m2 at T 100 = 70% transmission 4.50M 3 h Max op pressure 10 bar Min/Max ambient water temp. 5/40 0 C Emitter power W 80 Power 230/50 V/Hz Degree of protection IP 54 UV chamber 316 Ti S/S BMS connections for power & lamp failure Yes Inbuilt turbulators for agitation and even flow of water Yes Isolation valves each side of the install UV chamber Bypass valve & associated pipe-work if 1 system is installed otherwise a second unit in parallel acts as duty standby 240V 15 Amp Gpo with 1 meter of the installed UV system Fall to floor-waste in vicinity of UV chamber to drain during service Install in plant room or under all weather, sun-proof, vandal-proof well 3

HARVESTED RAINWATER POST & FINAL FILTRATION & UV DISINFECTION OPTIONS 2.50 L/s 3.05 L/s Automatic Post Filtration BWT Infinity A DIN 40mm 2.50 L/s DIN 50mm 3.05 L/s Install one or two BWT Infinity A automatic backwash filter DIN. Electronic timer with hour-day-week-month settings depending on the quality of the water, 90 micron anti-scale screen and associated connection module with male/male threaded unions. Each filter is capable of handling a peak demand flow rate of.l/s (Refer above) M * Install isolation valves each side of the filters * Tundish to floor-waste or stormwater * 240V 10Amp Gpo within 1 meter of the installed filters above the splash Line of the tundish * Install in a plant room or under all weather sun-proof, vandal-proof, well 4

Final bag filtration 1, 5, 10, 25, 50 microns 2.50L/s 3.05 L/s Install (2) two WFC X100B-FSIX100 polypropylene bag filter housing with legs; 2 inlet / outlet ports Supply only: (4) four WFC25X01-25 micron nominal polypropylene filter bags with polytec seal (two are spares) Install on a manifold in parallel Isolation valves each of the installed bag filter housings Pressure gauges each side of the filter housings Floor waste in vicinity of housing with fall to drain housings during filter bag change (Refer to attached installation & technical data) 5

BWT UV disinfection systems (where rain-water is in contact with humans) 2.50L/s 3.05 L/s Install: two BWT Bewades 100W100/11 LC 316 S/S ultra violet disinfection system on a manifold in parallel. Technical data: Nominal connection width DIN 50mm Max vol. flow 400 J/m2 at T 100 = 70% transmission 7.00M 3 h Max op pressure 10 bar Min/Max ambient water temp. 5/40 0 C Emitter power W 100 Power 230/50 V/Hz BMS connections for power & lamp failure Yes Inbuilt turbulators for agitation and even flow of water Yes Degree of protection IP 54 UV chamber 316 Ti S/S Isolation valves each side of the install UV chamber Bypass valve & associated pipe-work if 1 system is installed otherwise a second unit in parallel acts as duty standby 240V 15 Amp Gpo with 1 meter of the installed UV system Fall to floor-waste in vicinity of UV chamber to drain during service Install in plant room or under all weather, sun-proof, vandal-proof well 6

BWT UV disinfection systems (where rain-water is in contact with humans) 2.80L/s 5.50 L/s Install: (2) two BWT Bewades 200W200/11 LC 316 S/S ultra violet disinfection systems on a manifold in parallel Technical data: Nominal connection width DIN 50mm Max vol. flow 400 J/m2 at T 100 = 70% transmission 10.00M 3 h Max op pressure 10 bar Min/Max ambient water temp. 5/40 0 C Emitter power W 200 Power 230/50 V/Hz BMS connections for power & lamp failure Yes Inbuilt turbulators for agitation and even flow of water Yes Degree of protection IP 54 UV chamber 316 Ti S/S Install UV chambers on a manifold in parallel Isolation valves each side of the install UV chamber Bypass valve & associated pipe-work if 1 system is installed otherwise a second unit in parallel acts as duty standby 240V 15 Amp Gpo with 1 meter of the installed UV system Fall to floor-waste in vicinity of UV chamber to drain during service Install in plant room or under all weather, sun-proof, vandal-proof well 7

HARVESTED RAINWATER POST & FINAL FILTRATION & UV DISINFECTION OPTIONS 6.00 L/s 10.00 L/s BWT RF Multipur A DIN 65mm 6.00 L/s BWT RF Multipur A DIN 80mm 10.00 L/s * Install filters on a manifold in parallel * Isolation valves each side of the filters * Tundish to floor-waste or stormwater * 240V 10Amp Gpo within 1 meter of the installed filters above the splash Line of the tundish * Install in a plant room or under all weather sun-proof, vandal-proof, well (Refer attached installation & technical data) 8

Final bag filtration 1, 10, 25, 50 microns Duty 2.50 L/s 10.00 L/s Filter bag housings: Install: (2) two or three WFC BFS-2C 316-2-BSP-316L food quality stainless steel bag filter housings with band clamp closure, 2 BSP inlet/outlet ports that accept P2 size (7 OD x 32 long) filter bags. If flow rates are above 7.00 L/s consider a third or fourth system manifolded in parallel to share the load. Filter bags: Supply only: (4) four WFC BPG-25-2SS-25 micron nominal polypropylene P2 size filter bags with 316 stainless steel rings. (Two cartridges are spares) Install isolation valves each of the installed bag filter housings Install on a manifold in parallel Install Pressure gauges each side of the filter housings Install pressure differential switches across each housing with voltage free connections to BMS system to identify pressure due to blockages of the bag filters Floor waste in vicinity of housing with fall to drain housings during filter bag change 9

BWT UV disinfection systems (where rain-water is in contact with humans) 6.00 L/s 10.00 L/s Install (2) Two UV-disinfection units, manufacture BWT Type Bewades 240W80/22EU UV-disinfection units for microbiological control for drinking and process water - Suitable for wide transmission range (10-90% / 10 cm) - Optimum hydraulic design with Internal mixing devices for generation of turbulence for uniform UV-treatment and advanced disinfection performance - Power socket unit - Calibrated, UVC-selective high quality UV-sensor - Low-pressure UV-lamps with very long life time up to 14000 h - UV reaction chamber made of high grade stainless steel 316Ti - Integrated ballast unit - High quality quartz sleeves with expected life time of 3 years Microprocessor controlled unit "UV-Control II" with the following features: - measuring of radiation performance with digital display of UV intensity (% or W/mý) and 0/4.. 20 ma output for BMS - LED indication for power on, operation and failure - Hours run meter and counter for lamp activations - Supervision of each lamp with local and remote operation/failure indication and safety shut down - Adjustable warning and shut down threshold for low UV-intensity with local and remote alarm for BMS - Connection for external/remote control - Connections for: Shut-off valve Rinsing valve Thermostat Flow control device - Automatic rinsing can be initiated Time, temperature or flow controlled - Local and remote alarm (potential free contact) for failure indication available 10

Technical data: Connection width 80mm Nominal flow rate at transmission of 70 %/10 cm and UV-dose of 40 mws/cmý m3/h 22 (After 10000 h lamp life time) Nominal pressure max. bar 10 Water temperature min./max. øc. 5/30 Ambient temperature min./max.øc 5/40 Radiator performance W 200 Expect. Lamp life time h 12000-14000 UVC-performance W 63 Power supply V/Hz 230/50 Power consumption W approx 260 Number of radiators 3 Dimensions Width mm 219 Height mm 1165 * Free space above UV system for lamp replacement: mm 1000 11