Analysis of Air Flow and Heat Transfer in Ventilated Disc Brake Rotor with Diamond Pillars

Similar documents
Investigation for Flow of Cooling Air through the Ventilated Disc Brake Rotor using CFD

INVESTIGATION OF HEAT TRANSFER CHARACTERISTICS OF CIRCULAR AND DIAMOND PILLARED VANE DISC BRAKE ROTOR USING CFD

NUMERICAL INVESTIGATION OF FLUID FLOW AND HEAT TRANSFER CHARACTERISTICS ON THE AERODYNAMICS OF VENTILATED DISC BRAKE ROTOR USING CFD

SOLAR FLAT PLATE COLLECTOR HEAT TRANSFER ANALYSIS IN THE RAISER WITH HELICAL FINS Mohammed Mohsin Shkhair* 1, Dr.

CFD Analysis and Comparison of Fluid Flow Through A Single Hole And Multi Hole Orifice Plate

CFD Investigation of Influence of Tube Bundle Cross-Section over Pressure Drop and Heat Transfer Rate

ABSTRACT I. INTRODUCTION III. GEOMETRIC MODELING II. LITERATURE REVIW

THERMAL MANAGEMENT OF AIRCRAFT BRAKING SYSTEM

International Journal of Scientific & Engineering Research, Volume 5, Issue 7, July-2014 ISSN

NUMERICAL INVESTIGATION OF PISTON COOLING USING SINGLE CIRCULAR OIL JET IMPINGEMENT

Turbostroje 2015 Návrh spojení vysokotlaké a nízkotlaké turbíny. Turbomachinery 2015, Design of HP and LP turbine connection

Study on Flow Fields in Variable Area Nozzles for Radial Turbines

CONJUGATE HEAT TRANSFER ANALYSIS OF HELICAL COIL HEAT EXCHANGE USING CFD

International Journal of Engineering Research and General Science Volume 5, Issue 3, May-June, 2017 ISSN

Comparison of Swirl, Turbulence Generating Devices in Compression ignition Engine

CFD Analysis for Designing Fluid Passages of High Pressure Reciprocating Pump

FLOW AND HEAT TRANSFER ENHANCEMENT AROUND STAGGERED TUBES USING RECTANGULAR VORTEX GENERATORS

THERMAL STRESS ANALYSIS OF HEAVY TRUCK BRAKE DISC ROTOR

APPLICATION OF STAR-CCM+ TO TURBOCHARGER MODELING AT BORGWARNER TURBO SYSTEMS

Chapter 7: Thermal Study of Transmission Gearbox

Back pressure analysis of an engine muffler using cfd and experimental validation

CFD ANALYSIS ON LOUVERED FIN

Investigation of converging slot-hole geometry for film cooling of gas turbine blades

Effect of Stator Shape on the Performance of Torque Converter

Experimental Investigation of Heat Transfer characteristics Enhancement through Grooved Tube

ANALYSIS OF BLADES OF AXIAL FLOW FAN USING ANSYS. Mahajan Vandana N.,* Shekhawat Sanjay P.

Design and Test of Transonic Compressor Rotor with Tandem Cascade

Finite Element Analysis on Thermal Effect of the Vehicle Engine

Ansys-CFX Analysis on a Hatch-Back Car with Wheels and without Wheels

Experimental investigation of shell-and-tube heat exchanger with different type of baffles

CFD ANALYSIS OF FLUID FLOW AND HEAT TRANSFER IN A SINGLE TUBE-FIN ARRANGEMENT OF AN AUTOMOTIVE RADIATOR

CFD ANALYSIS OF PRESSURE DROP CHARACTERISTICS OF BUTTERFLY AND DUAL PLATE CHECK VALVE

Prediction of Thermal Deflection at Spindle Nose-tool Holder Interface in HSM

CFD Analysis of an Energy Scavenging Axial Flow Micro Turbine using Automotive Exhaust Gases

Enhance the Performance of Heat Exchanger with Twisted Tape Insert: A Review

Abstract In this study the heat transfer characteristics inside a rectangular duct with circular, rectangular, drop

EXPERIMENTAL INVESTIGATIONS OF DOUBLE PIPE HEAT EXCHANGER WITH TRIANGULAR BAFFLES

Performance Calculation of Vehicle Radiator Group using CFD

Simulation Studies on the Effect of Porous Twisted Plate Inserts on the Performance of Fire Tube Steam Packaged Boiler

Study of Inlet Guide Vanes for Centrifugal Compressor in Miniature Gas-Turbines

Effect of concave plug shape of a control valve on the fluid flow characteristics using computational fluid dynamics

COMPUTATIONAL ANALYSIS TO MAXIMIZE THE HEAT TRANSFER RATE OF DOUBLE TUBE HELICAL COIL HEAT EXCHANGER

Enhanced Heat Transfer Surface Development for Exterior Tube Surfaces

Aerodynamic Characteristics of Sedan with the Rolling Road Ground Effect Simulation System

Sports Car Brake Cooling Simulation with CAD-Embedded CFD

Numerical Investigation of the Effect of Excess Air and Thermal Power Variation in a Liquid Fuelled Boiler

INTERCOOLER FOR EXTREMELY LOW TEMPERATURES OF CHARGING

STRESS AND VIBRATION ANALYSIS OF A GAS TURBINE BLADE WITH A COTTAGE-ROOF FRICTION DAMPER USING FINITE ELEMENT METHOD

Efficiency Improvement in Shell and Tube Heat Exchanger Using CFD Tool

Design and Performance Analysis of Louvered Fin Automotive Radiator using CAE Tools

(1) Keywords: CFD, helicopter fuselage, main rotor, disc actuator

Engineering Success by Application of STAR-CCM+ for Modern Gas Turbine Design

INTERNATIONAL JOURNAL OF PURE AND APPLIED RESEARCH IN ENGINEERING AND TECHNOLOGY

CFD Flow Analysis and Optimization of Exhaust Muffler

Automation of Optimal Design of Air Preheater s Corrugated Heating Elements using CFD

PREDICTION OF PISTON SLAP OF IC ENGINE USING FEA BY VARYING GAS PRESSURE

ISSN (Online)

A Study on the Optimum Shape of Automobile Air Cleaner Diffuser

Scroll Compressor Oil Pump Analysis

International Engineering Research Journal Numerical Analysis of Heat Exchanger Tubes

University of Huddersfield Repository

Study of the Effect of CR on the Performance and Emissions of Diesel Engine Using Butanol-diesel Blends

Thermal Analysis of Shell and Tube Heat Exchanger Using Different Fin Cross Section

Static Structural and Thermal Analysis of Aluminum Alloy Piston For Design Optimization Using FEA Kashyap Vyas 1 Milan Pandya 2

A Study on Performance Enhancement of Heat Exchanger in Thermoelectric Generator using CFD

THERMAL ANALYSIS OF HELICALLY GROOVED COIL IN A CONCENTRIC TUBE HEAT EXCHANGER

NUMERICAL ANALYSIS OF HELICALLY COILED HEAT EXCHANGER USING CFD TECHNIQUE

Optimisation of Double Pipe Helical Tube Heat Exchanger and its Comparison with Straight Double Tube Heat Exchanger

Study of intake manifold for Universiti Malaysia Perlis automotive racing team formula student race car

CFD Simulation of a Scroll Compressor Oil Pumping System

51. Heat transfer characteristic analysis of negative pressure type EGR valve based on CFD

International Journal of Advance Engineering and Research Development

Impacts of Short Tube Orifice Flow and Geometrical Parameters on Flow Discharge Coefficient Characteristics

ADVANCES in NATURAL and APPLIED SCIENCES

Numerical Study on the Flow Characteristics of a Solenoid Valve for Industrial Applications

Measurement and Analysis of Underhood Ventilation Air Flow and Temperatures for an Off- Road Machine

e t Performance of Extended Inlet and Extended Outlet Tube on Single Expansion Chamber for Noise Reduction

Thermal Analysis of Helical and Spiral Gear Train

IJSRD - International Journal for Scientific Research & Development Vol. 3, Issue 11, 2016 ISSN (online):

NUMERICAL INVESTIGATION OF EFFECT OF EXHAUST GAS RECIRCULATION ON COMPRESSIONIGNITION ENGINE EMISSIONS

EFFECT OF SURFACE ROUGHNESS ON PERFORMANCE OF WIND TURBINE

Research in hydraulic brake components and operational factors influencing the hysteresis losses

EFFECTS OF PISTON SPEED, COMPRESSION RATIO, AND CYLINDER GEOMETRY ON SYSTEM PERFORMANCE OF A LIQUID PISTON

CFD analysis of triple concentric tube heat exchanger

GEOMETRICAL PARAMETERS BASED OPTIMIZATION OF HEAT TRANSFER RATE IN DOUBLE PIPE HEAT EXCHANGER USING TAGUCHI METHOD D.

FSI and Modal Analysis of Elastic Ring Squeeze Film Damper for Small Gas Turbine Engines

Australian Journal of Basic and Applied Sciences

Experimental and CFD Analysis of Exhaust Manifold to Improve Performance of IC Engine

Analysis of a turbine rim seal cavity via 3D-CFD using conjugated heat transfer approach

I. Tire Heat Generation and Transfer:

Load Analysis and Multi Body Dynamics Analysis of Connecting Rod in Single Cylinder 4 Stroke Engine

Muthoot Institute of Technology and Science, Varikoli, Kochi.

Modal Analysis of Automobile Brake Drum Based on ANSYS Workbench Dan Yang1, 2,Zhen Yu1, 2, Leilei Zhang1, a * and Wentao Cheng2

International Journal of Scientific & Engineering Research, Volume 6, Issue 10, October ISSN

[Rao, 4(7): July, 2015] ISSN: (I2OR), Publication Impact Factor: 3.785

Analysis of Aerodynamic Performance of Tesla Model S by CFD

Simulation of Performance Parameters of Spark Ignition Engine for Various Ignition Timings

IJESR/Oct 2012/ Volume-2/Issue-10/Article No-12/ ISSN International Journal of Engineering & Science Research

Static And Modal Analysis of Tractor Power Take Off (PTO) Gearbox Housing

Journal Online Jaringan COT POLIPD (JOJAPS) Fluid Flow Analysis of Micro Gas Turbine Using Computational Fluid Dynamics (CFD)

Transcription:

International Journal of Current Engineering and Technology E-ISSN 2277 4106, P-ISSN 2347 5161 2016 INPRESSCO, All Rights Reserved Available at http://inpressco.com/category/ijcet Research Article Analysis of Air Flow and Heat Transfer in Ventilated Disc Brake Rotor with Diamond Pillars Gorakh B. Kudal * and Mahesh R. Chopade Department of Mechanical Engineering, MIT College of Engineering, Pune-411038, India Accepted 15 June 2016, Available online 20 June 2016, Special Issue-5 (June 2016) Abstract The heat generated during braking operation is stored in brake disc and this heat is rejected to surrounding mainly by forced convection. Effective design of ventilated brake rotor is an essential to achieve proper cooling of braking system. The ventilated brake discs are available in various configurations such as radial type and pillared type brake rotors. It is found that thermal failure of brake disc is not only due to high temperature, but also due to high thermal stresses developed within rotor passages. The temperature distribution within vane passage of radial vane rotors is not uniform and it leads to high thermal stresses. Pillared rotors are alternative to radial vane rotors as they have more uniform temperature distribution within rotor passages. This topic mainly focuses on understanding of air flow and heat transfer characteristics of diamond pillared brake rotor. The CFD code is used to analyze and improve convective heat dissipation through passages of diamond pillared brake rotor. Validation is done for tapered radial vane (TRV) rotor, for which the experimental and numerical results are in good agreement. The modified configuration of diamond pillared brake rotor shows 11 % improvement in convective heat transfer coefficient as compared to baseline design of diamond pillared brake rotor. Keywords: Brake disc, ventilated, thermal failure, thermal stresses, diamond pillared rotor, CFD 1. Introduction 1 Braking system is an essential component of vehicle for its safety purpose. Braking system is mainly used to control and limit the vehicle speed as per the requirements. Frictional brakes are mainly classified into disc brakes and drum brakes. Disc brakes convert kinetic energy of vehicle into heat energy by pressing brake pad axially against a brake rotor. The drum brakes use shoes that are pressed against a drum. Under extreme condition such as descending a steep hill with a heavy load or a repeated high speed braking used in racing cars, drum brake would often lose their effectiveness and lead to brake fade. In this situation disc brakes are more suitable than drum brakes as they withstand in a very high temperature as compared to drum brakes. Long repetitive braking leads to temperature rise of various component of the vehicle brake system that reduces the performance of brake system. Therefore proper cooling of a vehicle braking system is an important safety issue. The temperature of brake rotor may reach very high during braking operation. Therefore, the disc brake must be able to dissipate the heat as fast as possible to ensure higher life expectancy. The brake discs are solid and ventilated type. The ventilated discs *Corresponding author: Gorakh B. Kudal are mainly used to improve cooling performance and its operation is similar as centrifugal impeller. Ventilated brake rotors are preferred over solid rotors due to their increased surface area of heat transfer and reduced mass. The air flow and heat transfer characteristics of ventilated disc brake rotors depend on various factors such as geometry of disc, air flow rate through rotor passages, passage turbulence intensity, rotational speed etc. Among all the above said parameters the aerodynamic flow characteristics highly dependent upon geometry of the disc and less dependent on rotational speed (D. Parish and D.G. MacManus, 2005). Therefore geometrical design of brake rotor is an important parameter which ensures proper cooling of braking system. The ventilated brake rotors are mainly classified into radial type and pillared type brake rotor. The radial type brake rotors are easy to manufacture as compared to pillared type rotors. The material distribution is more uniform in case of pillared rotors, which provides resistance to crack propagation and significantly lower thermal stresses (Lisa Wallis, et al, 2002). It is also found that thermal failure of brake rotor is not only due to high temperatures, but also due to high thermal stresses developed due to large temperature gradients. The pressure, velocity and temperature distribution within vane passages of straight radial vane configuration rotors is not uniform, 219 MIT College of Engineering, Pune, India, MECHPGCON 2016, INPRESSCO IJCET Special Issue-5 (June 2016)

which leads to high thermal stresses. Heat transfer from the rotor passages is symmetrical in case of pillared rotors. Hence, for modern high-speed vehicles, ventilated pillared rotors may be more appropriate as compared with straight radial vane configuration rotors (S. Manohar Reddy, et al, 2008). To improve the performance of a vented brake rotor, an understanding of air flow and heat transfer phenomena is very important. The flow through passages of the ventilated disc brake rotor is highly complex in nature and it can be better understood by using computational fluid dynamics (CFD). Numerical modeling can predict flow and heat transfer characteristics within passages of brake rotor and it can be used to improve cooling performance of brake rotor. brake rotor only a 20 0 segment (two passages) shown in figure 3 is considered rather than complete rotor, which reduces computational efforts. 2. Brake Disc Geometry Figure 1 shows the overall dimensions of diamond pillared brake rotor, which is considered for numerical analysis. The details about the rotor cross section are shown in figure 3. The rotor has 36 equally spaced flow passages. The arrangement of diamond pillars in flow passages shows the more uniform material distribution in rotor passages. Pillared rotors were mainly developed for high performance application such as racing cars where temperature of rotor may reach very high. Pillared rotors have advantages of curved vane rotors which increases braking performance. The present study is carried out at 800 rpm rotational speed, which is approximately 90 to 140 km/h for a typical four wheeled vehicle. Fig.2 Diamond Pillared Brake Rotor Fig.3 20 0 Segment of DP Brake Rotor 3. Computational Modeling and Simulation Fig.1 Disc Brake Rotor Geometry (Dimensions are in mm) The ICEM-CFD module of ANSYS is used for mesh generation and simulation is carried out in ANSYS Fluent. The main objective of this study is to understand the distribution of pressure, velocity and temperature within passages of diamond pillared brake rotor configuration. An attempt is made to enhance the convective heat transfer coefficient of diamond pillared brake rotor by understanding the air flow through passages of baseline design of diamond pillar. Modeling of diamond pillar brake rotor has been carried out using Creo Parametric 2.0. The baseline model of diamond pillar brake rotor is shown in figure 2. For numerical analysis due to rotational symmetry of 3.1. Meshing and Boundary Conditions The 3-D model of the diamond pillar brake rotor is imported in IGS format in ICEM-CFD for mesh 220 MIT College of Engineering, Pune, India, MECHPGCON 2016, INPRESSCO IJCET Special Issue-5 (June 2016)

generation. The brake rotor is treated as spinning in an infinite environment and hence open boundary conditions are applied at domain wall. At the inlet and outlet boundary of the domain, pressure of one atmosphere is specified. The computational domain is also a 20 0 segment with radius 290 mm and length 120 mm, which is large enough to avoid any effect on the flow through passages of brake rotor. Due to rotational symmetry periodic boundary conditions are applied to either side of the segment which represents entire rotor. Rotor walls are assumed at constant temperature. The details of boundary conditions and external domain are shown in figure 4. Fig.4 CFD Model with Boundary Conditions In order to capture curved surfaces and wall properties, the model is discretized using hexahedral mesh elements. Fine mesh is employed near wall to capture both the velocity and thermal boundary layer. The hexahedral mesh model of diamond pillar is shown in figure 5. The meshing is checked which gives a minimum angle of 36 0 and minimum determinant of 0.65. The meshing is also checked for other issues such as volume, surface orientation, minimum required quality in order to achieve correct results and better convergence. incompressible ideal gas. Radiation and buoyancy effects are neglected. The surrounding pressure and temperature are assumed as 101325 Pa and 300 K. The simulation is carried out by assuming rotor walls at constant temperature of 700 K for rotational speed of 800 rpm. The two fluid zones are created. The outer fluid is stationary, while inner fluid is rotating. These two fluid zones are interfaced by creating appropriate mesh interfaces available in ANSYS Fluent. The solid zone is not created as constant wall temperature condition is assumed for all rotor walls. 3.2. Validation and Grid Independence The experimentation was performed on tapered radial vane (TRV) rotor. Firstly the brake disc was heated around 100 0 C by a surface heater of rating 1.0 kw. A maximum temperature of 100 0 C was chosen to minimize heat lost by radiation. When temperature of rotor became uniform, the surface heater was removed and the brake disc was rotated at constant speed of 500 rpm. The rotor was driven by 2 hp, 3 phase induction motor, with speed control by variable frequency drive. The power is transmitted from motor to rotor via torque limiter and bearing assembly. Torque limiter is provided to avoid motor stall conditions while breaking. During rotation the temperature drop was recorded from 87 0 C for each minute by infrared temperature meter. The convective heat transfer coefficient is calculated by using the law of energy conservation, which is given below, Amount of stored heat lost by rotor = amount of heat carried by air m C p dt/dt = h A (Tw T atm) 8.31*566*0.134 = h*0.27*(86.8 24.4) h = 37.41 W/m 2 K The value of convective heat transfer coefficient obtained from CFD is 35.80 W/m 2 K The % deviation between experimental and CFD result is % difference = % difference = 4.30 % Fig.5 Hexahedral Meshing for DP Brake Rotor The rotational speed of rotor is constant; therefore a moving reference frame is employed for the analysis. The flow of air is considered to be steady and The deviation between experimental and CFD result is about 4.30 %, which is in good agreement. The grid independence study was carried out with grid sizes of 224000, 275000, 330000, 389000, 432000, 495000 and 581000 cells for baseline diamond pillared brake rotor configuration. The figure 6 shows value of convective heat transfer coefficient for corresponding grid size. It was observed that the variation in convective heat transfer coefficient becomes negligible for grid sizes more than 432000; therefore it was decided to use 432000 cells for all other configurations. 221 MIT College of Engineering, Pune, India, MECHPGCON 2016, INPRESSCO IJCET Special Issue-5 (June 2016)

Heat Transfer Coefficient, W/m 2 K Gorakh et al 42.5 42 41.5 41 40.5 40 224 275 330 389 432 495 581 Number of Cells 1000 Fig.5 Convective heat transfer coefficients against grid sizes (a) Temperature Contour 3.3. Modifications in Diamond Pillared Brake Rotor The modifications are done based on the flow analysis of baseline diamond pillared brake rotor. The specific objective is to reduce the size of recirculation area lies at upper side of diamond pillars. The recirculation regions reduce the air mass flow rate and hence convective heat transfer through rotor passages. To reduce the size of recirculation area all the diamond pillars are tilted in direction of rotation (clockwise direction). The modifications in diamond pillars are done with the following assumptions: i. The size of diamond pillars are kept constant and only their orientation is changed. ii. The length of outer pillars can be changed to fit them at outer radius. (b) Velocity Streamlines 3.4. Flow and Heat Transfer Analysis Figure 6 shows temperature, velocity streamlines and velocity vector plots at the passages of baseline diamond pillared brake rotor configuration. The analysis is carried out at 800 rpm rotational speed and 700 K wall temperature. From vector plot, it is seen that the recirculation region lies at upper side of diamond pillars. The recirculation region decreases air mass flow rate and the convective heat transfer through rotor passages. From temperature contour, it is seen that the rate of convective heat transfer is very low at the recirculation regions. Therefore it is necessary to decrease area of recirculation region lies within rotor passages. Based on this objective modifications are done by tilting all diamond pillars in clockwise direction. (c) Velocity Vector Fig.6 Results for Baseline Diamond Pillared Brake Rotor 222 MIT College of Engineering, Pune, India, MECHPGCON 2016, INPRESSCO IJCET Special Issue-5 (June 2016)

The effect of inclination of pillars on convective heat transfer is analyzed by increasing angle of inclination of all pillars by 5 0. In this way the new brake rotor designs with inclination given to all pillars viz. 5 0, 10 0, 15 0 and 20 0 are studied. As angle of inclination increases the recirculation area lies at upper side of pillars decrease, which improves air mass flow rate and convective heat transfer through rotor passages. As we increase angle of inclination, the air flow becomes more re-aligned and reduces recirculation area. The velocity vectors for modified diamond pillar configurations are shown in figure 7. From vector plots, it is seen that with increase in angle of inclination of pillars from 0 to 20 0, the area of recirculation zone decreases, which shows improvement in convective heat transfer through rotor passages. Beyond 20 0 inclination, the reduction in recirculation area was very less, therefore further modifications were not considered. (c) 15 0 Inclination (a) 5 0 Inclination (d) 20 0 Inclination Fig. 7 Results for Modified Diamond Pillared Configurations (b) 10 0 Inclination The table 1 gives information about improvement in convective heat transfer coefficient for modified geometries of diamond pillared brake rotor configuration along with baseline design. The convective heat transfer coefficient increases around 11 % at angle of inclination of 20 0 given to all pillars. Beyond that the improvement in convective heat transfer coefficient is negligible, therefore further modifications are not considered. For 20 0 inclinations design the mass flow rate increases by 16.11 %. The improvement in mass flow rate is due to reduction in recirculation areas presented in rotor passages. The reduction in recirculation areas is the key parameter to improve convective cooling performance of brake rotors. 223 MIT College of Engineering, Pune, India, MECHPGCON 2016, INPRESSCO IJCET Special Issue-5 (June 2016)

Table 1: Convective heat transfer coefficient and mass flow rate at 800 rpm for modified diamond pillar brake rotor designs Brake Rotor Design Convective Heat Transfer Coefficient, hconv (W/m 2 K) Relative Difference (%) Mass Flow Rate (g/s) Relative Difference (%) Baseline 42.16-1.08-5 0 inclination 44.12 4.65 1.109 2.68 10 0 inclination 45.02 6.78 1.174 8.70 15 0 inclination 45.37 7.61 1.215 12.50 20 0 inclination 46.80 11.00 1.254 16.11 Conclusions In the present study, the flow and heat transfer characteristics of diamond pillared brake rotor are studied by using computational fluid dynamics (CFD). Based on the above study, the following conclusions are drawn. 1) The recirculation regions in the flow passages reduce the convective heat transfer and air mass flow rate through rotor passages. 2) At the recirculation region the air becomes more stagnant which increases temperature at that location and it might promote the hot spots. Therefore it is necessary to reduce the area of recirculation region. 3) The area of recirculation regions has reduced by tilting all the diamond pillars in the direction of rotation of rotor. Due to this modification, the flow pattern became more re-aligned. 4) The modification has improved convective heat transfer coefficient about 11 % for 20 0 inclination provided to all pillars. Beyond that the improvement in heat dissipation was negligible. 5) Due to reduction in recirculation area, the air mass flow rate through rotor passages has also increased. At extreme for 20 0 inclination of pillars, the air mass flow has improved by 16 %. References Reddy S., Mallikarjuna J., Ganesan V. (2008), Flow and Heat Transfer Analysis of a Ventilated Disc Brake Rotor Using CFD, SAE Technical Paper 2008-01-0822. Lisa Wallis et al. (2002), Air Flow and Heat Transfer in Ventilated Disc Brake Rotors with Diamond and Tear-Drop Pillars, Numerical Heat Transfer, Part A, 41:643-655. K. M. Munisamy, N. H. Shuaib, M. Z. Yusoff and S. K. Thangaraju (2013), Heat Transfer Enhancement on Ventilated Disc Brake Disc with Blade Inclination Angle Variation, International Journal of Automotive Technology, Vol. 14, No. 4, pp. 569-577. Parish D., MacManus D. G. (2005), Aerodynamic Investigations of Ventilated Brake Discs, Proceedings of Institution of Mechanical Engineers, Part D: Journal of Automobile Engineering, 219, p.471-486. Thundil Karuppa Raj Rajagopal et al. (2014), Numerical Investigation of Fluid Flow and Heat Transfer Characteristics on the Aerodynamics of Ventilated Disc Brake Rotor using CFD, Thermal Science, Vol. 18, No. 2, pp. 667-675. Reddy S., Mallikarjuna J., Ganesan V. (2006), Effect of Vane Shape on Flow and Heat Transfer Characteristics of a Brake Disc, Proceedings of the 3rd BSME-ASME International conference on Thermal Engineering 20-22 December, 2006, Dhaka, Bangladesh. F Talati and S Jalalifer (2007), Investigation of Heat Transfer phenomenon in a Ventilated Disc Brake Rotor with Straight Radial Vanes, Journal of Applied Sciences 8(20): 3583-3592. A. Nejat, E. Mirzakhalili, M. Aslani and R. Najian Asl (November 2011),Heat Transfer Enhancement on Ventilated Brake Disc using Airfoil vanes, Journal of Thermal Science and Engineering, Vol. 3, No. 4, pp. 569-579. A.D. McPhee (2007), Experimental Heat Transfer and Flow Analysis of a Vented Brake Rotor, International Journal of Thermal Sciences, page 4,7. Carlos Hannover Galindo-Lopez, Thesis on Optimization of Convective Heat Dissipation from Ventilated Brake Discs, May 2009. Gautam Pulugundla, Thesis on CFD Design Analysis of Ventilated Disc Brakes, May 2008 Zhongzhe Chi, Thesis on Thermal Performance Analysis and Geometical Optimization of Automotive Brake Rotor, July 2008, pp. 57-85. 224 MIT College of Engineering, Pune, India, MECHPGCON 2016, INPRESSCO IJCET Special Issue-5 (June 2016)