Nevro Lead Compatibility

Similar documents
Vercise PC Implantable Pulse Generator

Precision Spectra System Implantable Pulse Generator

Infographics on Electromobility (January 2019)

Vercise Gevia 16 Contact Implantable Pulse Generator

Global Dialysis - Cost per Dialysis Session

Vercise TM DBS Charging Handbook

BP Statistical Review of World Energy June 2017

Total credit to the non-financial sector (core debt), % of GDP Table F1.1

I. Global wine markets,

Rectangular photoelectric proximity switches

Primary energy. 8 Consumption 9 Consumption by fuel. 67 th edition

Imports of seed for sowing by country Calendar year 2011 Source: ISF compilation based on official statistics and international seed trade reports

Lifting Instructions for 1336 PLUS and FORCE D Frame Drives

AUSTRIA. Table 1. FDI flows in the host economy, by geographical origin. (Millions of US dollars)

FEDERAL RESERVE statistical release

Thermal Coal Market Presentation to UNECE Ad Hoc Group of Experts on Coal in Sustainable Development December 7, 2004

Information Technology and Economic Development: An Introduction to the Research Issues

Packing Data Installation Instructions

Performance Derby: MSCI Regions/Countries Earnings & Revenues Growth 2019E / 2018E / 2017A

CSM-K. high capacity clean steam generator

I. World trade in Overview

67 th edition. Renewable energy. Appendices. 44 Other renewables consumption 45 Biofuels production

WORLD MOTOR VEHICLE PRODUCTION BY COUNTRY AND TYPE QUARTERS June 14, 2018

Allen-Bradley 1397 Pulse Encoder Interface Card

Spain s exports by oil product group and country of destination

Fork through-beam sensors

NI PS-15/16/17 Side Mount Brackets


CrimpTest-1 kn. Calibration Bracket

Fork through-beam sensors

19,000 38,500. Mean Crop. 5, ,827 Max , ,869 Last Year 6, ,

PLASTIC WELDING. New! TRIAC AT. Intelligent and robust.

KINGDOM OF CAMBODIA NATION RELIGION KING 3

KINGDOM OF CAMBODIA NATION RELIGION KING 3

KINGDOM OF CAMBODIA NATION RELIGION KING 3

Table 23 Production of minor oil products from refineries - by type Thousand metric tons

KINGDOM OF CAMBODIA NATION RELIGION KING 3

KINGDOM OF CAMBODIA NATION RELIGION KING 3

KINGDOM OF CAMBODIA NATION RELIGION KING 3

35,000 52,000 87,000 1,600 8, ,400 76,600. Mean Crop. Monthly YTD Min ,671 8,211 Max. 2017

KINGDOM OF CAMBODIA NATION RELIGION KING 3

KINGDOM OF CAMBODIA NATION RELIGION KING 3

testing to perfection MultiTest-i Technical Datasheet

UView Mini Transilluminator

DOUBLE OCTOMILL TM PRODUCT RANGE

KINGDOM OF CAMBODIA NATION RELIGION KING 3

Table 5 Production, trade and supply of hard coal Thousand metric tons and kilograms per capita

Table 5 Production, trade and supply of hard coal Thousand metric tons and kilograms per capita

PLASTIC WELDING. New! TRIAC AT. Intelligent and robust.

Production of minor oil products from refineries - by type Thousand metric tons

Made UNDER high pressure

Spain s exports by oil product group and country of destination. Year Corporación de Reservas Estratégicas de Productos Petrolíferos

1. INTERNATIONAL OVERVIEW. 1.0 Area and population. population (1,000) area

INSTALLATION GUIDE NI WSN-3291 Outdoor IP Enclosure For NI WSN-32xx Series Devices

Global Competitiveness Index Rankings

Coal. 36 Reserves and prices 38 Production and consumption. 67 th edition

ISO Interface. Large capacity. Light weight. Accommodates enclosure IP65. Solenoid Valve (with M Connector) Conforming to ISO

World Air Conditioner Demand by Region

Product Overview INCH

ING Economic Forecasts

Market Briefing: Global Markets

The new. Class ZURCON Z20 / Z22. New worldclass polyurethane materials. ZYour Partner for Sealing Technology

9.01 ICT use for business-to-business transactions

UAE draft regulation for Electric Vehicle

ING Economic Forecasts

ING Economic Forecasts

(annual average compound growth rate)

EVOline Socket Modules

Civil Dialogue Group on WINE Thursday April 19th, 2018

Potential Danger of Fire or Explosion Read this letter now!

Table F3.1 TIMSS 4th grade scores by GDP per capita (PPP), GDP per capita (USD) Math score

Universal Charging and Testing Unit FPU-1 for Bladder, Piston and Diaphragm Accumulators

Global Threat Reduction Initiative Foreign Research Reactor Spent Nuclear Fuel Shipments

United States 1,263, % % Total 3,150, % 97, %

RISK DASHBOARD ANNEX CREDIT RISK PARAMETERS Q2 2017

RISK DASHBOARD ANNEX CREDIT RISK PARAMETERS Q4 2017

World real merchandise trade grows faster than output

Global Valuation Summary - SAMPLE PAGES

Natural gas. 26 Reserves 28 Production and consumption 33 Prices 34 Trade movements. 67 th edition

Table 13 Production, trade and supply of conventional crude oil Thousand metric tons; kilograms per capita; reserves production ratio (R/P) in years

The new STx chain hoist NEW. Sophisticated technology prepared for the future

Fiche 1 Quelques données de la Banque Mondiale

M O T O R V E H I C L E S T A T I S T l C S

Appendix L: Data Sets in Printed Form

Electrophoresis + Blotting + Imaging. V3 Western Workflow Visualize. Verify. Validate.

Summary of debt securities outstanding

Cotton This Month. Major Changes in Supply and Demand Estimates and Projections

JURISDICTIONS PARTICIPATING IN THE CONVENTION ON MUTUAL ADMINISTRATIVE ASSISTANCE IN TAX MATTERS

Global Economic Briefing: Merchandise Trade

Production (bbl/day)

Global Medium & Heavy Commercial Vehicle Model Level Production Forecast Report. From 2001 to 2021

Universal Charging and Testing Unit FPU-1 for Bladder, Piston and Diaphragm Accumulators

Chit Chats clients save up to 70% on U.S. and international postage.

Table 13 Production, trade and supply of conventional crude oil Thousand metric tons; kilograms per capita; reserves production ratio (R/P) in years

Table 13 Production, trade and supply of conventional crude oil Thousand metric tons; kilograms per capita; reserves production ratio (R/P) in years

2.01 Availability of latest technologies

PREVIEW. Fieldbus System for Distributed I/O NEW PRODUCTS

Charging and testing unit FPU for Bladder, Piston and Diaphragm Accumulators

HELICOPTERS Service. Helicopter Maintenance Upgrades

LPI ranking and scores, 2014

Transcription:

Nevro Lead Compatibility Directions for Use 91131569-01 REV B CAUTION: Federal law restricts this device to sale, distribution and use by or on the order of a physician.

Guarantees Boston Scientific Corporation reserves the right to modify, without prior notice, information relating to its products in order to improve their reliability or operating capacity. Drawings are for illustration purposes only. Trademarks All trademarks are the property of their respective owners. Additional Information For contraindications, warnings, precautions, adverse events, storage and handling, sterilization, clinical studies supporting the use of the neurostimulation system, programming, labeling symbols, warranty, or other device-specific information not included in this manual, refer to the appropriate Directions for Use for your Boston Scientific SCS System as listed on your Boston Scientific Reference Guide. 91131569-01 REV B ii of ii

Introduction Introduction This manual outlines instructions for connecting Boston Scientific Spinal Cord Stimulator (SCS) devices to specific Nevro SCS Leads and Lead Extensions (see Lead Compatibility ) in a trial or permanent implant procedure. Boston Scientific recommends that physicians and healthcare providers read all applicable product labeling before implanting Boston Scientific devices. Intended Use The Boston Scientific SCS Implantable Pulse Generators, OR Cables, and Lead Extensions can be connected to compatible Nevro Leads and Lead Extensions as part of a spinal cord stimulation procedure. Lead Compatibility The Boston Scientific Implantable Pulse Generators, OR Cables, and Lead Extensions are compatible with the Nevro Leads and Lead Extensions listed in Table 1. Table 1: Compatible Nevro Leads and Lead Extensions Product Number Product Description LEAD2008-25B Blue Lead Extension Kit, 25 cm LEAD2008-35B Blue Lead Extension Kit, 35 cm LEAD2008-60B Blue Lead Extension Kit, 60 cm LEAD1058-30B Blue Lead Kit, 30 cm with 5 mm spacing LEAD1058-50B Blue Lead Kit, 50 cm with 5 mm spacing LEAD1058-70B Blue Lead Kit, 70 cm with 5 mm spacing LEAD1058-90B Blue Lead Kit, 90 cm with 5 mm spacing TLEAD1058-50B Trial Lead Kit, 50 cm with 5 mm spacing TLEAD1058-70B Trial Lead Kit, 70 cm with 5 mm spacing TLEAD1058-90B Trial Lead Kit, 90 cm with 5 mm spacing WARNING: The Nevro Leads and Lead Extensions have not been tested for compatibility with an MRI environment when used with the Boston Scientific SCS Systems. MRI scanning can result in severe patient injury. 91131569-01 REV B 1 of 6

Directions for Use Section A: Connecting Boston Scientific Trial System Device after a Nevro Trial Procedure This section outlines instructions for connecting the Boston Scientific SCS Trial Systems to the Nevro Trial or Perm Leads. Avoid using excessive force during surgery as this may damage the Lead Extension. Do not sharply bend or kink the Lead Extension. Do not tie suture(s) directly to the Lead Extension; use the provided suture sleeves or anchors. Avoid handling the Lead Extension with sharp instruments; use only rubber-tipped forceps. Take care when using sharp instruments such as hemostats or scalpels to prevent damaging the Lead Extension. Remove body fluids from the end of the Lead connector before connecting it to any other component. Fluid contamination of these connections could compromise the integrity of the stimulation circuit. 1. Consult the Nevro product labeling for instructions on removing the Nevro OR Cables and Trial Stimulator. 2. Ensure that stimulation is OFF and disconnect the Nevro OR Cables and Trial Stimulator. 3. Ensure that the Nevro Lead (s) or Lead Extensions (s) are intact. 4. If a Lead Extension is required, connect each Nevro Lead to each Boston Scientific Extension as follows: a. Wipe the proximal end of the Lead to ensure that it is free of fluids. b. Insert the proximal end of the Lead into the Lead Extension Connector until it stops and the retention ring is under the setscrew. Ensure that the Lead is fully inserted before proceeding to the next step to prevent Lead damage. NOTE: If there appears to be an obstruction when inserting the Nevro Lead into the Boston Scientific Lead Extension Connector, turn the hex wrench counterclockwise to loosen the setscrew, and/or gently rotate the lead to help advance the proximal end. When using the Hex Wrench, ensure that it is fully seated in the setscrew. 5. Connect each Lead or Lead Extension to the Boston Scientific OR Cables as detailed in the Trial Manual provided for your SCS system. 6. Connect the Boston Scientific OR Cables to the Boston Scientific External Trial Stimulator as detailed in the Trial Manual for your SCS system. 7. Link the Boston Scientific External Trial Stimulator to the Boston Scientific Clinician Programmer or Boston Scientific Remote Control to verify that components are properly connected. The Clinician Programmer and Remote Control displays impedances for each lead contact. Impedances may result from open or unconnected wires. For programming instructions, refer to the programming Directions for Use for your SCS system as listed in your Reference Guide. 8. If a Boston Scientific Lead Extension was used in Step 4, use the Hex Wrench to turn the Extension Connector setscrew clockwise until it clicks, indicating that it is locked. Ensure that the Hex Wrench is fully seated in the setscrew before tightening. The Hex Wrench is torque-limiting and cannot be overtightened. 9. If needed, create an appropriately-sized pocket using blunt dissection on either side of the midline for coiled excess Leads, Lead Extensions, or both. 91131569-01 REV B 2 of 6

Directions for Use 10. Place a small loop at the lead for slack. If necessary, loosely tie a suture around the lead-loop. Do not tighten the suture onto the lead as this may cause Lead damage. 11. If necessary, carefully remove excess slack by gently pulling the extensions from the exit wound. 12. Place and tape a stress relief loop and dress the wound. Use standard aseptic dressing technique at the exit site and at the lead junction for the duration of the trial period. 13. To connect Nevro Perm Leads to a Boston Scientific Implantable Pulse Generator after the trial phase, consult the appropriate Directions for Use provided with your Boston Scientific Implantable Pulse Generator for detailed implant procedure. 14. To replace Trial or Perm leads with permanent Boston Scientific Leads and Implantable Pulse Generator, consult the appropriate Directions for Use provided with your Boston Scientific Leads and Implantable Pulse Generator. Section B: Connecting Boston Scientific Devices after a Nevro Permanent Implant This section outlines instructions for connecting permanently implanted Nevro Leads and Lead Extensions to a Boston Scientific Implantable Pulse Generator. 1. Consult the appropriate product labeling to explant the Nevro Implantable Pulse Generator. 2. If a Boston Scientific Trial procedure will be performed with a Boston Scientific Lead Extension, follow Steps 4-12 in Section A. 3. To connect the Nevro Lead or Lead Extension to the Boston Scientific Implantable Pulse Generator, consult the appropriate product labeling provided with your Boston Scientific Implantable Pulse Generator. 91131569-01 REV B 3 of 6

Customer Service - USA To order replacement parts, or for answers to any questions you might have, please contact the Customer Service Department: Phone: (866) 360-4747, +1 (661) 949-4747 Fax: +1 (661) 949-4022 Boston Scientific Neuromodulation 25155 Rye Canyon Loop Valencia, CA 91355, USA Customer Service - Outside USA If you have any other questions or need to contact Boston Scientific, choose your locality from the contact list. Argentina T: +5411 4896 8556 F: +5411 4896 8550 Australia / New Zealand T: 1800 676 133 F: 1800 836 666 Austria T: +43 1 60 810 F: +43 1 60 810 60 Balkans T: 0030 210 95 37 890 F: 0030 210 95 79 836 Belgium T: 080094 494 F: 080093 343 Brazil T: +55 11 5853 2244 F: +55 11 5853 2663 Bulgaria T: +359 2 986 50 48 F: +359 2 986 57 09 Canada T: +1 888 359 9691 F: +1 888 575 7396 Chile T: +562 445 4904 F: +562 445 4915 China Beijing T: +86 10 8525 1588 F: +86 10 8525 1566 China Guangzhou T: +86 20 8767 9791 F: +86 20 8767 9789 China Shanghai T: +86 21 6391 5600 F: +86 21 6391 5100 Colombia T: +57 1 629 5045 F: +57 1 629 5082 Czech Republic T: +420 2 3536 2911 F: +420 2 3536 4334 Denmark T: 80 30 80 02 F: 80 30 80 05 Finland T: 020 762 88 82 F: 020 762 88 83 France T: +33 (0) 1 39 30 97 00 F: +33 (0) 1 39 30 97 99 Germany T: 0800 072 3301 F: 0800 072 3319 Greece T: +30 210 95 42401 F: +30 210 95 42420 Hong Kong T: +852 2960 7100 F: +852 2563 5276 Hungary T: +36 1 456 30 40 F: +36 1 456 30 41 India Bangalore T: +91 80 5112 1104/5 F: +91 80 5112 1106 India Chennai T: +91 44 2648 0318 F: +91 44 2641 4695 91131569-01 REV B 4 of 6 India Delhi T: +91 11 2618 0445/6 F: +91 11 2618 1024 India Mumbai T: +91 22 5677 8844 F: +91 22 2617 2783 Italy T: +39 010 60 60 1 F: +39 010 60 60 200 Korea T: +82 2 3476 2121 F: +82 2 3476 1776 Malaysia T: +60 3 7957 4266 F: +60 3 7957 4866 Mexico T: +52 55 5687 63 90 F: +52 55 5687 62 28 Middle East / Gulf / North Africa T: +961 1 805 282 F: +961 1 805 445 The Netherlands T:+31 30 602 5555 F: +31 30 602 5560 Norway T: 800 104 04 F: 800 101 90 Philippines T: +63 2 687 3239 F: +63 2 687 3047 Poland T: +48 22 435 1414 F: +48 22 435 1410 Portugal T: +351 21 3801243 F: +351 21 3801240 Singapore T: +65 6418 8888 F: +65 6418 8899 South Africa T: +27 11 840 8600 F: +27 11 463 6077 Spain T: +34 901 111 215 F: +34 902 267 888 Sweden T: 020 65 25 30 F: 020 55 25 35 Switzerland T: 0800 826 786 F: 0800 826 787 Taiwan T: +886 2 2747 7278 F: +886 2 2747 7270 Thailand T: +66 2 2654 3810 F: +66 2 2654 3818 Turkey Istanbul T: +90 216 464 3666 F: +90 216 464 3677 Uruguay T: +59 82 900 6212 F: +59 82 900 6212 UK & Eire T: +44 844 800 4512 F: +44 844 800 4513 Venezuela T: +58 212 959 8106 F: +58 212 959 5328

Customer Service - Outside USA This page intentionally left blank 91131569-01 REV B 5 of 6

Legal Manufacturer AUS Australian Sponsor Address Boston Scientific Neuromodulation Boston Scientific (Australia) Pty Ltd Corporation PO Box 332 25155 Rye Canyon Loop BOTANY Valencia, CA 91355 USA NSW 1455 (866) 789-5899 in US and Canada Australia (661) 949-4000, (661) 949-4022 Fax Free Phone 1800 676 133 (866) 789-6364 TTY Free Fax 1800 836 666 www.bostonscientific.com Email: neuro.info@bsci.com EC REP EU Authorized Representative Boston Scientific Limited Ballybrit Business Park Galway, Ireland T: +33 (0) 1 39 30 97 00 F: +33 (0) 1 39 30 97 99 2016 Boston Scientific Corporation or its affiliates. All rights reserved. 91131569-01 REV B 2016-12