ASSA ABLOY Series Power Operator Installation and Instruction ASSA Manual ABLOY ASSA ABLOY

Similar documents
ASSA ABLOY Series Power Operator Installation and Instruction ASSA Manual ABLOY ASSA ABLOY

5600 Series Power Operator Installation and Instruction Manual

Requirements LEO Power Operator Installation Instructions Patents: 5,881,497; 7,316,096; 7,484,333 CAUTION CAUTION WARNING

Requirements LEO Power Operator Installation Instructions Patents: 5,881,497; 7,316,096; 7,484,333 CAUTION CAUTION WARNING

5700 Series Power Operator Hinge (Pull) Side Mount Installation and Instruction ASSA Manual ABLOY

5700 Series Power Operator Stop (Push) Side Mount Installation and Instruction

WARNING: Make sure that (120V, 60Hz) input power is turned off at facility s main circuit breaker before proceeding with installation.

ASSA ABLOY Series Multi-Point Hold Open Installation and Instruction Manual

ASSA ABLOY MPI (Infinite Hold Open Range) Support Unit Models. Multi-Point Electromechanical Overhead Concealed Closer Holder Releasing Device

Full-featured operator with slim profile for moderate to high traffic applications LOW ENERGY OPERATOR CATALOG

Power drill Center punch Wire stripper

6900 Series PowerMatic Low Energy Power Operator

6900 Series PowerMatic. Low Energy Power Operator

T57 SERIES LOW ENERGY OPERATOR INTRODUCTION FEATURES BENEFITS PATENTS TABLE OF CONTENTS

Series 9540 J9540. Installation Instructions Multi-Sized 1 to 6 Non-Hold Open. Regular Arm Applications. Parallel Arm Applications

7100SZ Series SafeZone Installation and Instruction Manual

Superior door control for rigorous, high-use applications 6000 LOW ENERGY OPERATOR CATALOG

Multi-point closer/holder with motion sensor 7100SZ DOOR CLOSER CATALOG

7100SZ SERIES. Multi-Point Closer/Holder with Motion Sensor

Installation Instructions Series 78-B/FHA Hold Open

Concealed overhead closer for high-end applications DOOR CLOSERS CATALOG

7100SZ Series SafeZone. Multi-Point Closer/Holder with Motion Sensor

7100SZ Series SafeZone. Multi-Point Closer/Holder with Motion Sensor

ASSA ABLOY. 7100SZ Series SafeZone External Sensor. Installation and Instruction Manual ASSA ABLOY. Patent Pending

Electro-Mechanical Swing Operator. Table of Contents

Electromagnetic Door Holder/Releases

5700 SERIES Low Energy Power Operator

Regenerative power door operator for moderate to high traffic applications SERIES ADAEZ LOW ENERGY OPERATOR CATALOG

TS93 EMF T/PT/TDE. Surface applied door closer

TS9356 PKT 90/119. Surface applied door closer. Installation instructions: Pocket door track mount in 90 /119 pocket (Closer on wall)

6900 PowerMatic Low Energy Power Operator Installation Instructions CAUTION CAUTION WARNING

LCN AUTOMATIC OPERATORS

Hinge (Pull) Side Door Application DC6230 Series Multi-Sized 1 thru 6 DC6430 Series Half-Size 1 thru 6. Door Mounted DC6230 & DC6430

M670/M680BD MAGNALOCK SERIES Installation Instructions

Regenerative power door operator for moderate to high traffic applications SERIES ADAEZ LOW ENERGY OPERATOR CATALOG

Model 2300DL Installation Guide

*24771* 4040SE DE Sentronic. 1 Voltage. 7 Regulation. 2 Track. 8 Door Closer Cover. 3 Spring Power. 4 Arm Installation. 5 Arm Screw.

9000 Series Trinity The world's most intelligent door closer

FIRE/LIFE SAFETY CLOSERS/HOLDERS SERIES

2300 OPERATING/APPLICATION/INSTALLATION INSTRUCTIONS

Closer with traditional styling for low to moderate traffic openings 78-B/F DOOR CLOSER CATALOG

HIGH SECURITY CLOSERS SERIES

Senior Swing Control Box. Table of Contents

Model 2300JL Installation Guide

*28101* 4600 Electronic Low Energy Operator Installation Instructions 4630 PULL SIDE MOUNT 4640 PUSH SIDE MOUNT. Table of Contents.

DC3210 Series. Multi-Sized 1 thru 6 DEEP REVEAL APPLICATION WITH M103 OPTION(615F59 CLAMP KIT) Recommended Closer Size

ACSI MODEL 1406BB-04-AO POWER SUPPLY INSTALLATION INSTRUCTIONS

HIGH SECURITY SERIES

9540 SERIES. Cast Iron Door Closer

KEANE MONROE a member of the record group

INSTALLATION AND OPERATING INSTRUCTIONS For Model GL1 Gate Locks

TS93 PT/PTH. Surface applied door closer. Installation instructions: Push side track mount with dead stop (PT) Optional hold open (PTH)

ASSA ABLOY Universal Door Closers with Heavy Duty Spring Stop Parallel Arms

78-B/F Series. Traditional Door Closers

MAXIGARD A2000 SPEED SWITCH. Introduction

SW10 (Full Power) & SW19 (Low Energy)

2904 Power Supply Installation Instructions I-EA00041

ASSA ABLOY Universal Door Closers

7800 & 7900 Powered Door Operators Premier Product

ARCHITECTURAL CONTROL SYSTEMS, INCORPORATED ST. LOUIS, MISSOURI

Installation Instructions (07-08) CAUTION

8. Do not install this product on the exterior of buildings. 9. Do not use as a doorstop. This will void warranty. Installation Instructions

Package Contents. Mounting Hardware

Copyright , 2018 Yale Security Inc., an ASSA ABLOY Group company. All rights reserved. Reproduction in whole or in part without the express

B100S - Super Swing. Instruction Manual. Document number: B100S-C Release: V4.0 Date: May 08,2009

FIRE/LIFE SAFETY SERIES PRODUCT SELECTION GUIDE

Alliance Towel Dispensing System. Operation Manual

*29268* 4600CS Electronic Low Energy Operator 4630CS PULL SIDE MOUNT 4640CS PUSH SIDE MOUNT. Table of Contents. Customer Service

MODEL 600LB 600 POUND SINGLE MAGNETIC LOCK WITH LED, BOND SENSOR & DOOR STATUS SENSOR SPECIFICATIONS

Electrical Options Booklet. Table of Contents

HOW TO TELL HAND OF DOOR:

INSTALLATION GUIDE For Surface Mounted Applications (Purchased after 08/01/2018)

ED50. Low energy automatic swing door operator. Service Manual

SYMBOL LEGEND DANGER WARNING NOTE THIS INDICATES DANGER TO THE LIFE AND HEALTH OF THE USER IS APPROPRIATE PRECAUTIONS ARE NOT TAKEN

5300 Series 5300 SERIES

5800 Series ADAEZ PRO Low Energy Operator

7570 SERIES Security Door Closer

PRODUCT INFORMATION BULLETIN

High Security Closers Series

Hunter Automatics HA-8. Installation Manual

Instruction Manual for the. E-SL 450 Series

DC5000 Series. Cam Action Door Closer

Standard Plastic Template P/N: (3-0) P/N: (4-0)

ARCHITECTURAL PRODUCT GUIDE

Installation Instructions

High Security Closers Series

SYMBOL LEGEND DANGER WARNING NOTE THIS INDICATES DANGER TO THE LIFE AND HEALTH OF THE USER IS APPROPRIATE PRECAUTIONS ARE NOT TAKEN

Electrohydraulic Powered Systems

Handy Lift HD Owners Manual WARNING. BURR 500 lb. Capacity Handy Lift HD PN (40 ) PN (45 ) PN (50 )

Norton ABS-AMERICAN BUILDING SUPPLY, INC Series Multi-Sized Closers - Packed 6 per case

Installation Instructions CAUTION

ADA EZ Rev. H, 8/23/11

ADA Compliant Solution REV

Multi-sized cast iron closer for high use applications DOOR CLOSER CATALOG

Handy Lift LT Owners Manual

*24213* 4040-SE Sentronic. 1 Voltage. 6 Adjusting Hold-Open Door Position. 7 Regulation. 2 Tracking. 8 Door Closer Cover.

Operating Instructions Type MPT 53

Installation and Wiring Instructions for the TL- Prefix SARGuide Illuminated Touchpad for 80 Series Exit Devices to ElectroLynx Connector System

TEL: G&C Electronics CC E. T.

PCS 100 SYSTEM INSTALLATION INSTRUCTIONS

Transcription:

00 Series Power Operator Installation and Instruction ASSA Manual ABLOY Item No. Description Motor (00M) Cover (00COV) Control Inverter (00IN) Power Supply VDC (00PS) Track Assembly (0-) / Replacement Motor Key (00KEY) Tools required: Allen wrench set (inch) Flat blade screwdriver (potentiometer & terminal size) Screwdriver (Phillips size ) Tape ruler Use screw pack and hardware provided to mount operator. Power drill Center punch Wire stripper #7 drill /-0 tap (metal frame install) WARNING: To reduce the risk of injury to person, use this operator only with: Pedestrian Swing doors. ETL certified; conforms to ANSI/UL standard for automatic closing doors. Copyright 0, 0 Yale Security Inc., an Group company. All rights reserved. 80-9-000-00 (0-)

Door Prep Hollow Metal Door Frame Reinforcing Frame Material Ga..0 (.) Ga..077 (.90) Ga..098 (.) 8 Ga..078 (.) Recommended Ga..0 (.) 0 Ga.. (.) 0 Ga.. (.) 8 Ga.. (.8) Fasteners for Frame Reinforcing Min. Required 8 Ga..078 (.) Ga..0 (.) Ga..0 (.) 0 Ga.. (.) /-0 Machine screws for hollow metal and aluminum. No. x-/" (70mm) long sheet metal screws for wood. Door Frame /8" () Templating is based on /8" gap between door and frame. Notes: All dimensions are given in inches. Thickness recommended for reinforcements in hollow metal doors and frames is charted at the left of this page. Do not scale drawing. This template information based upon use of " maximum width butt hinges. Maximum frame reveal is " for this application. Before beginning the installation, verify that the door frame is properly reinforced and is well anchored in the wall. Unreinforced hollow metal frames and aluminum frames should be prepared and fitted with /-0 blind rivet nuts, furnished by others. Concealed electrical conduit and concealed switch or sensor wires should be pulled to the frame before proceeding. Technical Data Input power: Power consumption: Circuit breaker: Power supply: Door width*: Door weight: Door opening angle: Hold open time: *Interior Doors Only 0VAC, 0Hz. amps amps V DC, max.. Amp. -" (8-9cm) 00-0 lb. (-8 kg) Pull arm: 80-9, with reveal 0 - /8" (0 - mm) 0-0 seconds (A.D.A. seconds min.) Notes: Input connections - torque to.8 in/lbs (.nm) Permanent wiring is to be employed as required by local codes. Activation devices: push plates, access control, mats, touchless wall switches, etc. Maximum wire size is: AWG at terminals HOT and COM (0VAC; 0Hz) on T Power Input Terminal. AWG at terminals thru on Accessory Terminal. Copyright 0, 0 Yale Security Inc., an Group company. All rights reserved. 80-9-000-00 (0-)

Operator Mounting Left hand door illustrated.. Using template, locate and prepare holes in the frame.. Drill #7 and tap /-0 Machine Screws or Self Drilling Screws ( places). " -/" -/8" -/8" " -/" C L Hinge -/" " Bottom of Frame!! See page 0 for removable template. WARNING DO NOT REMOVE ARM FROM OPERATOR! WARNING ARM MUST CLEAR TOP OF DOOR. Attach Operator Attach operator to frame using supplied screws. Track Mounting Using template, locate and mount track. Track MUST be flush with top of door. C L Screw C L Hinge " SNAP - Insert end caps - Attach screws - Snap on track cover Copyright 0, 0 Yale Security Inc., an Group company. All rights reserved. 80-9-000-00 (0-)

Attach Arm Attach arm to track slider using provided allen wrench. Turn screw counter-clockwise. Determine Hand of Door Right Hand Left Hand A - Door Mounting ON = RH OFF = LH - ON = Push & Go OFF = Door Closer Mode A Adjustment of Closed and Open Position Magnets are used to signal the unit at closed and fully open positions. With door in the closed position, slide Close Position Magnet so it aligns directly with the sensor. With door in the open position, slide Open Position Magnet so it aligns directly with the sensor. Note: Magnets must be adjusted to meet specific application needs. Latch and backcheck positions depend on magnet positions. Sensor Close Position Magnet Open Position Magnet Copyright 0, 0 Yale Security Inc., an Group company. All rights reserved. 80-9-000-00 (0-)

7 Activation Connection See wiring diagram examples on pages 7-9. B F B Relay output (K) Relay output (K) VDC (+) VDC (-) F VDC Power Supply for Powered Accessories 8 Grounding C C! WARNING UNIT WILL NOT FUNCTION CORRECTLY WITHOUT PROPER GROUNDING GROUND WIRE MUST BE SECURED TO BACKPLATE UNDER HEAD OF (GREEN) GROUND SCREW LABELED GND. 9 Power Connection Input Wiring Instructions Terminal COM HOT Description Common power lead (Neutral) Hot power lead (0VAC, 0Hz) D D Breaker Switch HOT COM Copyright 0, 0 Yale Security Inc., an Group company. All rights reserved. 80-9-000-00 (0-)

0 Power-On Procedures. Align Close Position Magnet with sensor.. Turn power on at the Unit On/Off Switch located on the end cap.. Turn Breaker Switch to "Reset" (Breaker Switch shown in step 9). Red LED in breaker should be on and circuit board LEDs should illuminate. Sensor Close Position Magnet Open Position Magnet E Control Set-Up Inverter Control Board Adjustments: Based on function adjustment desired, use table below to determine which POT is to be adjusted. Required: Magnets must be adjusted for specific application. POT ADJUSTMENT TABLE DESCRIPTION FUNCTION H/O TQ Motor Torque at Hold Open CW - Increase Backcheck Position CCW - Decrease P Sweep Closing Force (90-0 ) CW - Increase CCW - Decrease M/DLY Motor Delay on Opening CW - Increase CCW - Decrease H/O TM Hold Open Time ( - 0 Seconds) CW - Increase CCW - Decrease OBSTR SENS Obstruction Detection on Open CW - Increase CCW - Decrease P Latch Force (0-0 ) CW - Increase CCW - Decrease OBSTR SENS H/O TM SW0 PUSH PULL ON K K PB COM SNS COM E P JMP0 NO TB0 NC M/DLY P H/O TQ STATUS LEDS WARNING ELECTRIC SHOCK RISK! (Adjustments made in the shaded area should be performed by Authorized Factory Personnel.) MOTOR OUT /0VAC IN W V U L 0Y L L Y Signage Affix "Caution" Labels on both sides of the door. Labels should be centered across the width of the door and 0" from the floor. Center 0" Copyright 0, 0 Yale Security Inc., an Group company. All rights reserved. 80-9-000-00 (0-)

Wave to Open Switch Wiring Notes:. Power input to Door Operator Unit is at T Power Input Terminal (not shown) 0VAC 0Hz.. Wave to Open Switch can be ordered separately or as a kit. Wave to Open Switch (back side) Operation: Relay output (K) Relay output (K) VDC (+) VDC (-) Door is normally closed. Activating Wave to Open Switch will open the door. The door will close after hold open delay elapses. Standard Function with Switches Notes:. Power input to Door Operator Unit is at T Power Input Terminal (not shown) 0VAC 0Hz. Wall Switch, Card Reader, Key Switch, etc. Normally Open Momentary dry contacts Operation: Relay output (K) Relay output (K) VDC (+) VDC (-) Doors are normally closed. Door Activating either switch will open both doors. Door will close after hold open time delay has elapsed. Relay output (K) Relay output (K) VDC (+) VDC (-) Optional Door Wall Switch, Card Reader, Key Switch, etc. Normally Open Momentary dry contacts Copyright 0, 0 Yale Security Inc., an Group company. All rights reserved. 7 80-9-000-00 (0-)

Radio Frequency Function Option Notes:. Power input to Door Operator Unit is at T Power Input Terminal (not shown) 0VAC 0Hz.. Radio Frequency Feature can be purchased as a separate kit and installed as pictured below. RF Receiver Unit Relay output (K) Relay output (K) VDC (+) VDC (-) Operation: Door is normally closed. Activating wireless switch or hand held wireless transmitter will open the door. Door will close after hold open delay elapses. Door MHz Receiver (Mounted on Operator) Wiring for Momentary Hold Open Function Relay output (K) Relay output (K) VDC (+) VDC (-) Optional Door Fail Secure / Fail Safe Electric Strike Wiring Operation: Door is normally closed and latched. Activating switch will unlock the electric strike and the door will automatically open. Door will close after hold open time delay has elapsed. Jumper Settings NC Place jumper to upper position for normally closed (Fail Safe) operation or to lower position for normally open (Fail Secure) NO operation. JMP0 For Fail Secure Strike The door will remain locked during power failure. For Fail Safe Strike The door will unlock during power failure. Relay output (K) Relay output (K) VDC (+) VDC (-) Wall Switch, Card Reader, Key Switch, etc. Normally Open Momentary dry contacts + - Jumper wire ga or larger copper wire only (not provided) Copyright 0, 0 Yale Security Inc., an Group company. All rights reserved. - DC Electric Strike 8 80-9-000-00 (0-)

Fail Safe Electromagnetic Lock VDC Wiring Notes:. Power input to Door Operator Unit is at T Power Input Terminal (not shown) 0VAC 0Hz.. Unit s Relay Rating: 0VDC @ A or VAC @.A Operation: Door is normally closed and latched. Jumper Settings Place jumper to upper position for normally closed operation. NC NO JMP0 Activating switch will cut power to mag lock and the door will automatically open. Door will close after hold open time delay has elapsed. The door will unlock during power failure. Relay output (K) Relay output (K) VDC (+) VDC (-) Wall Switch, Card Reader, Key Switch, etc. Normally Open Momentary dry contacts - Jumper wire ga or larger copper wire only (not provided) + - VDC Electromagnetic Lock (Fail Safe) Executive Feature Operation: Door is normally closed and latched. Activating switch will open the door and the door will stay open until the button is depressed again, then the door will close and latch. OBSTR SENS H/O TM SW0 PUSH PULL ON K K PB COM SNS COM P JMP0 NO TB0 NC M/DLY P F H/O TQ STATUS LEDS J0 MOTOR OUT /0VAC IN W V U L 0Y L L Y F Notes:. All switches, latches, and other accessaries should be connected according to standard wiring instructions.. Recommend RF kit #7 for use with Executive Feature. Jumper Settings WITH POWER DISCONNECTED, Place jumper on pins and to activate the Executive Feature program. J0 Normal operation Executive operation Copyright 0, 0 Yale Security Inc., an Group company. All rights reserved. 9 80-9-000-00 (0-)

PULL SIDE Left Hand Door Illustrated " /-0 Machine Screws or Self Drilling Screws ( Places) /" -/8" -/" -/8" -/8" -/" " -/" " Frame Ø 7/8" Door */8" 9" -/8" *CRITICAL: Required for proper installation " C L Hinge or Pivot PULL SIDE Right Hand Door Illustrated -/" " " -/" " -/8" -/8" -/" -/8" /" /-0 Machine Screws or Self Drilling Screws ( Places)! WARNING Arm must clear top of door. Do Not Remove Arm From Operator! Ø 7/8" Frame Door */8" 9" " -/8" *CRITICAL: Required for proper installation C L Hinge or Pivot Copyright 0, 0 Yale Security Inc., an Group company. All rights reserved. 0 80-9-000-00 (0-)

Troubleshooting Fault Possible Reasons Why Remedies/Explanations The door does not open - the motor does not start - the motor continues to run The door does not close The door opens and stays open when first energized. The electric strike or electromagnetic lock does not work. Control switch is set to OFF position Circuit breaker is set to OFF position Electrical power is missing Activation unit does not function Motor is driving in wrong direction Something jammed beneath the door Arm has come loose Closing power set too low Arm has come loose The door is binding or obstructed Control switch is set to OFF position SW0 is set incorrectly JMP0 is set incorrectly Loose or shorted wire to strike or lock Power from unit insufficient for strike or electromagnetic lock Change the setting of the ON/OFF switch Reset the circuit breaker to the ON position Check the electrical power switch Jump activation input to verify Flip Door Mounting Dip Switch to other direction Remove object Re-install arm and key Adjust P or P according to instructions on pg. 8 Re-install arm and key Inspect hinges and frame for wear or obstruction Change the setting of the ON/OFF switch Change the switch setting to the correct handing. See instructions on page See instructions on page 8 or 9 Inspect wires running from unit to latch device Provide power to strike or electromagnetic lock from another source. Maintenance (Service by Authorized Personnel Only): Disconnect power before servicing. Frequency of maintenance will depend on factors such as traffic, climate, etc. To make sure your operator is working correctly you should periodically check wire connections, tightness of arm connection and screws, and wear and tear on hinges/pivots. No serviceable user parts! Copyright 0, 0 Yale Security Inc., an Group company. All rights reserved. 80-9-000-00 (0-)

Operation: General Information Your Low Energy Operator can be configured in three variations to meet the standards:. Push plates, Wave-to-open switches, etc. are available to activate the operator.. Push & Go can be enabled. In this mode, your door is pushed (or pulled) manually, and then automatically opens to full open position.. Door can be used as a manual door (Door Closer Mode). The door will work and act like a standard door closer, with power, when pushed or pulled open manually. Push plates still active. If desired, overhead presence devices can be provided for an extra level of protection. Consult local authority having jurisdiction. These are not required by current ANSI/BHMA A.9 standards. Opening: When an opening signal is received by the control unit, the door opens to the fully open position. The open position is held by the motor. If the door is obstructed while opening, the door will stop; the operator will sense obstruction and the door will close. Note: Door must be visible by person operating activation switch(es). Auxiliary door stop (by others) required. Closing:! When the hold open time has elapsed, the operator will close the door automatically, using the motor. The door will slow to low speed at latch before it reaches the fully closed position. The door is kept closed by low power. If the door is obstructed while closing, the door will stop; the operator will sense obstruction, stop and stall. If obstructed more than two minutes, the unit will turn off. To reset, manually close the door, cycle power and turn switch on. Activate push plates to test operation. WARNING: Make sure that (0V, 0Hz) input power is turned off at facility s main circuit breaker before proceeding with installation. Do not remove arm for installation. For assistance, contact Norton Technical Product Support at 877-97-. Copyright 0, 0 Yale Security Inc., an Group company. All rights reserved. 000 Highway 7 East Monroe, NC 8 Tel: (877)- 97- Fax: (800)-8-09 www.nortondoorcontrols.com 80-9-000-00 (0-)