INSTRUCTION MANUAL MODEL PS VDC POWER SUPPLY

Similar documents
Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment

INSTRUCTION MANUAL DIGITRAC % 2 DIGITAL TENSION READOUT AND CONTROL

MAGPOWR Spyder-Plus-S1 Tension Control

EZ-TRAC Digital Tension Readout and Control

INSTRUCTION MANUAL GLOBAL SERIES BRAKE MODELS: GBA, GBAM, GBB, GBBM, GBC, GBCM, GBD, GBDM, GBE, GBEM

TRAC-3 TENSION READOUT AND CONTROL

5001TCP SPEED CONTROLLER

PM300 VOLTAGE REGULATOR INSTRUCTION MANUAL

5001TCP SPEED CONTROLLER

Original Instructions INSTRUCTION MANUAL Model GTSCM / GTSDM Load Cells For Under Pillow Block Applications

MAGPOWR DLCA Digital Load Cell Amplifier

RODIX, INC. FC-40-PLC Plus Series Control Troubleshooting Guide for Circuit Board P/Ns and

PM300E Voltage Regulator Instruction Manual

ESC2301. Universal Electronic Governor Controller Operation Manual

SCCP PWM Charge Controller/Load Manager Owner s Manual

EUROTHERM ONTROLS. Two phase thyristor power switches. Product data

D-70, D-140, D-210, and D-280 Series Electric Non-Spring Return Actuators

Dycon D1532SM. EN50131/PD6662 Grade 3, 12V 2A Power Supply. Technical Description Installation and Operating Manual DYCON POWER SOLUTIONS LTD

Dycon D2430 EN54-4 Fire Alarm Power Supply Series

EG3000. Generator Electronic Governor Controller Operation Manual

INSTRUCTION MANUAL FOR VOLTAGE REGULATOR APR P/N

CP-9301 CP Application. Features. Applicable Literature. Electronic Actuator Drives General Instructions

ESD5500E Series Speed Control Unit

MAGPOWR DTR-65 Digital Load Cell Amplifier

CBC-300 Series & CBC-300C Series Dual Channel Adjust Clutch/Brake Controls

SAX Electronic Valve Actuator

INSTRUCTION MANUAL FOR. VOLTAGE REGULATOR Model: APR Part Number:

LC BATTERY CHARGER OPERATION & MAINTENANCE GUIDE

FLÄKTGROUP PM-MOTOR WITH INTEGRATED FC 106 FREQUENCY CONVERTER

DIN Rail UPS Model: DIN-UPS Installation/Operation Manual

DIN Rail UPS DC UPS/Battery Detection System Model: BDS-DIN-UPS Installation/Operation Manual

DC3N Non-Regenerative DC Drives

ENGINE GOVERNING SYSTEMS

Description 1/8-7.5HP

SB 2000 PUSH TO SEARCH NEXT STAG E. Aerotech, Inc. FORM: QM 1320

BT300 HVAC Drives Conventional Bypass (C-Bypass) Options

DC3E Non-Regenerative DC Drive User Guide 1/4 to 2 HP, 115/230 VAC M/N DC3N-12D AI M/N DC3N-12D-4X-010-AI

Continental Hydraulics Installation Manual CEM-AA-A

& HIGH CURRENT DC POWER SUPPLIES INSTRUCTION MANUAL

CBC-300 & CBC Series Dual Channel Adjust Clutch/Brake Controls

TECHNICAL DATASHEET#TD1516AX 3 AMP SOLENOID DRIVER

Application Engineering

Matrix APAX. 380V-415V 50Hz TECHNICAL REFERENCE MANUAL

ESD-5550/5570 Speed Control Unit. Manual

ABB Component Drives ACS150, 0.5 to 5 Hp

Speed Sensor. Inputs: Safety Information. Outputs. Wiring Diagram. Electrical Data: NOTICE

SAV Electronic Valve Actuator

How to Select the RE Industrial Actuator Part Number

User Manual of 2MA2282

G203V / G213V MANUAL STEP MOTOR DRIVE

Fan Coil Unit (FCU) Fan Motor Control

Application Engineering

Models. Output current max.* Output Power max. Low Line : VAC High Line: VAC 24 VDC / 12 A 240 W. Back up battery

Quick guide. Plug-in fans GPPM with FC101_106 August 2014

USERS MANUAL MCD REMOTE OPERATOR

Sentry Battery Charger. Installation and Operations Manual Section 75

RCP200 Series Motor Controls. Instruction Manual Model RCP Model RCP Model RCP202-BC1 Model RCP202-BC2 Model RCP205-BC2

SALDET SALES & SERVICE, INC. CLINTON TOWNSHIP, MICHIGAN

ESD5550 / 5570 Series Speed Control Units

Flowrite 599 Series SAX Electronic Valve Actuator Non-spring Return, 24 Vac, 3-Position Control

MAGPOWR HEB250 High Efficiency Brake

PowerOhm Installation Manual for BM R Series Braking Modules

DO NOT INSTALL, REMOVE, OR REWIRE THIS EQUIPMENT WITH POWER APPLIED.

Observe all necessary safety precautions when controlling the soft starter remotely. Alert personnel that machinery may start without warning.


FT-1005 Air Volume/Velocity Transducer. Operation & Maintenance Manual. Engineered for accuracy, applicability, durability and simplicity

Modulating control valves with magnetic actuators, PN 16

User s Manual. For DM860T. Fully Digital Stepper Drive. Version 1.0 Designed by StepperOnline All Rights Reserved

ENGINE GOVERNING SYSTEMS LSM672 LOAD SHARING MODULE. GOVERNORS AMERICA CORP. 720 Silver Street Agawam, MA , USA MEMBER

17429X.00 SERIES MODELS:

INSTALLATION, OPERATION AND MAINTENANCE MANUAL. MODEL PF1 Rated 15,25,40 & 70 Amps, Single Phase SCR Power Controls. ISE, Inc

User Manual. T6 Tachometer. Online: Telephone: P.O. Box St. Petersburg, Florida 33736

PL900 ILLUMINATOR. Fiber-Lite. Operation Manual. Setup. Fiber Optic Connection A PRODUCT OF DOLAN-JENNER INDUSTRIES. Voltage Selection:

EDG6000 Electronic Digital Governor

REFERENCE MANUAL FORM: MX-TRM-E REL REV MTE

User Guide. Model Insulation Tester / Megohmmeter. Introduction

PowerOhm Installation Manual for BM R Series Braking Modules

Manual of ST 6/8 controller

USER MANUAL MODELS NRG02-D240AC-4Q NRG02-D240AC-4Q-PCM NRG05-D240AC-4Q NRG05-D240AC-4Q-PCM NRG10-115AC-4Q NRG10-115AC-4Q-PCM

Electrical data Nominal voltage AC/DC 24V Nominal voltage frequency 50/60Hz

SPECIFICATIONS ATTENTION OPERATION DESCRIPTION

USER'S MANUAL MODEL DPD60001 MICROSTEP DRIVER PACK

LDX-C120 Series is a 120 W integrated DIN Rail Battery Charger / DC UPS Power Supplies, suitable for wide variety of industrial applications.

A6Z OPERATING MANUAL

ESD-5500E Series - Speed Control Unit

User Manual. Solar Charge Controller 3KW

DC3R Regenerative DC Drive User Guide 1/4 to 2 HP, 115/230 VAC

ESD5100 Series Speed Control Unit PART NUMBER ESD5120 ESD (127)

Models: User s Manual. Pulse-Width Modulated, Adjustable Speed Drives for DC Brush Motors

Data Sheet for Precision Potentiometer

12 Series Linear Actuators. Operation & Maintenance Manual, Analog Positioner Installation

1100 Series Piston Type Differential Pressure Gauges

OPERATING MANUAL. Cole-Parmer Stir-Pak General-Purpose Laboratory Mixer. Model Number General-Purpose Laboratory Mixer System

RVS-DN Digital Reduced Voltage Motor Starter

Users Manual. Accessories Motor and Phase Rotation Indicator ships with the following items: 3 test leads 3 test probes 3 alligator clips 9 V battery

Powers TM Controls EA 338 Electronic Actuator

VA-715x Electric Valve Actuator

XR500B Universal Voltage Regulator

MEDICAL IRRIGATION K PUMP OPERATING MANUAL: Manufactured for: K.M.I 3185 Palisades Dr Corona CA USA Model No.

PowerOhm Installation Manual for LG ATV Series Braking Modules

Transcription:

222 W. Memorial Road, Oklahoma City, OK 73114-2317 Phone: 1-800-624-7697 Fax: 405-755-8425 www.magpowr.com E-mail: magpowr@magpowr.com INSTRUCTION MANUAL MODEL PS-24 24 VDC POWER SUPPLY All of the information herein is the exclusive proprietary property of Maxcess International, and is disclosed with the understanding that it will be retained in confidence and will neither be duplicated nor copied in whole or in part nor be used for any purpose other than for which disclosed. Copyright 2004, all rights reserved. Periodically there will be updates to this manual. The latest version is available at www.magpowr.com or by calling 1-800-MAGPOWR (624-7697). 1.0 Introduction The MAGPOWR Model PS-24 is a controllable current regulator for 24 vdc magnetic particle clutches and brakes. The PS-24 also provides a small amount of reverse current to maximize the torque range of the clutch / brake. The PS-24 may be powered from either 24 vac or 24 vdc. The Model PS-24 has three jumper selectable current ranges. Maximum outputs for the individual ranges are 0.5, 1.0 and 2.0 adc. The appropriate range is determined by the current rating of the clutch or brake to be controlled. For best torque control resolution, the lowest current range providing sufficient current for maximum operating torque should be selected. When using 24 vdc input power the maximum current output will be slightly less than the selected range. The PS-24 accepts either a remote adjustment potentiometer, or a 0 to 10 vdc analog control signal. An isolation card is required when the PS-24 is connected to an external non-isolated control signal. Connections are provided for an external 1 madc current meter. The meter display will indicate output current as a percentage of the output range selected. The control circuits are not electrically isolated from the power circuits. The control circuit negative is connected to the P.E. connection, i.e., control input circuits are not floating. 2.0 Installation The PS-24 is intended for installation on a vertical panel with a DIN 35 rail, with the wiring terminals facing down. Figure 1 shows the enclosure dimensions. Wiring to and from the PS-24 must be done with double or reinforced insulation or protective screening which provides protective separation. All wiring should comply with the essential requirements of the appropriate standard(s) and is the responsibility of the installer. 850A302-1 06/05 REV. B

Route input power away from control signal wiring. Connect shields of shielded cable to the terminals indicated as SHIELD. Maximum exposed shield length and maximum length of wires outside of the shield is 3 in. (75 mm). 2.30 [58.4 mm] 6.18 [157.0 mm] A Maxcess International Company 1.39 [35.2 mm] 3.38 [85.9 mm] PS-24 MODEL: CLUTCH-BRAKE POWER SUPPLY Figure 1 Enclosure Dimensions 3.0 Setup Remove the enclosure top by inserting a flat blade screwdriver under the retaining tabs in the base (See figure 2). Set the J1 input voltage selection jumper to either AC or DC depending on input voltage type. Set the current range selection jumpers to the range appropriate for the clutch / brake connected to the PS-24 (See figure 3 for J2 current range settings). The factory setting is 1/2 amp range. Replace the enclosure top. J1 J2 Figure 2 Figure 3 Enclosure Top Removal J2 Current Range Settings 2

4.0 Electrical Connections Figure 4 shows the connections that are required for the basic system. They are: 24 vac/vdc power 24 vdc output for clutch / brake 1 to 10 kohm Potentiometer Route input power away from control wiring. The clutch / brake wires and the remote meter wires should be twisted pair. Run the signal input wiring in shielded cable. Connect the shield to the provided terminal marked SHIELD. The maximum shield length and maximum length of wires outside of the shield is 3 in. (75 mm). When using a 0 to10 vdc input instead of a potentiometer, connect the negative of the input to terminal 26 and the positive of the input to terminal 25. The 0 to 10 vdc signal should be isolated from PE. If not isolated from PE, EMC performance may be degraded. The 0 to 1 madc output and the potentiometer input negative lead is ground referenced. The 24 vdc output must be floating with respect to ground. When using multiple PS-24's, each one must have its own power supply. ISOLATED 24 VAC, 50/60 Hz or 24 VDC POTENTIOMETER or 0-10V INPUT 24V 24V 1mA AC/DC OUTPUT METER L1 L2 + - + - SHIELD + - 1 2 3 4 5 6 7 23 24 25 26 24 VDC ONLY 1 2 3 CLUTCH/ BRAKE REMOTE METER 0-1 ma DC (OPTIONAL) SWITCH NOT ALLOWED IN D.C. OUTPUT CW 1K TO 10K REMOTE POTENTIOMETER Alternate wiring for non-isolated 24 vdc supply. EMC performance may be degraded. Do not use with AC supply. Figure 4 Electrical Connections for PS-24 5.0 Maintenance The only maintenance that may be required on the PS-24 is fuse replacement. Replacement of the fuse(s) requires first removing input power, then opening the enclosure. The enclosure must be re-installed to maintain the IP rating. The enclosure may be opened by inserting a flat blade screwdriver under the retaining tabs in the base (See figure 2). 3

6.0 Troubleshooting Symptom Possible Cause Solution or Diagnostic No clutch / brake No input power. Verify incoming power is correct output. voltage and frequency. J1 selection wrong. Fuses blown. Clutch / brake wires open circuit. Remote potentiometer or external power supply not wired correctly, or shorted together. Verify J1 is set to AC or DC to match the type of power input. Clutch / brake wires shorted together or shorted to ground. Disconnect clutch / brake wires at the PS-24 and check for proper clutch / brake resistance between the wires. Voltage between terminal 24 and 26 should be 10 vdc. Voltage between terminal 25 and 26 should vary from 0 to 10 vdc as the potentiometer or external 0 to10 vdc power supply is moved through its range of travel. Remote meter not working. Incorrect type of meter. Meter wires shorted or open. Meter should be a current meter with 1 madc full scale and no more than 100 ohm resistance. Disconnect meter wiring at the PS-24 and check for proper meter resistance between the wires. 4

7.0 Specifications Supply Voltage: 24 vdc, 2.1 amp maximum, 49 va with clutch or brake coil 24 vac, +/- 10%, 50/60 Hz, 2.1 amp maximum, sinusoidal, 49 va with clutch or brake coil Fuses: F1 2.5 amp, Littelfuse Part No. 21602.5, or Wickmann Part No. 19194-058-FS F2 5.0 amp, Littlefuse Part No. 216005, or Wickmann Part No. 19194-063-FS Enclosure: IP20 Climatic Class: 3K3 (EN60721) Temperature Range: Operating: 0 C to 50 C Storage: -30 C to 80 C Relative Humidity: 5% to 85% Pollution Degree: 2 (IEC664-1) Altitude: 0 to 2000 m Compatible Residual Current Device Types: Worst Case Fault Current: A or B (IEC755) 2.5 amp Inputs: Signal Potentiometer: 1 to 10 kohm, ¼ watt minimum or Voltage: 0 to 10 vdc, 100 kohm input impedance Outputs: Clutch / Brake Voltage: Current: Regulation: Current Drift: Meter Signal: Potentiometer Supply Voltage: -1.2 to 24 vdc, duty cycle/phase controlled Adjustable in three ranges: -0.016 to 0.5 adc -0.032 to 1.0 adc -0.064 to 2.0 adc < 1% of range 0.024 %/ C 0 to 1 madc, +/-3% into 100 ohm maximum 10 vdc +/-3%, 10 madc maximum