Question Set(2017) Switch Gear & protection(5 th SEm) 9. Explain the construction and operating principle with proper diagram:

Similar documents
TIME SCHEDULE MODULE TOPICS PERIODS. On completion of this course the student will be able:

AD Table 3.--Goodrich Evacuation Systems Installed on Certain Airbus Model Airplanes

APPENDIX I Annual production of selected automobile industry in India (in thousands)

THE TECHNICAL STANDARDS AND SAFETY ACT 2000, S. O. 2000, c and -

ELECTRICAL POWER and POWER ELECTRONICS

A Research, Science and Discovery based Polyurethane Technology company

The University of New South Wales. School of Electrical Engineering and Telecommunications. Industrial and Commercial Power Systems Topic 6

GOVERNMENT OF PAKSITAN MINISTRY OF FINANCE, ECONOMIC AFFAIRS, STATISTICS AND REVENUE (REVENUE DIVISION) **** NOTIFICAITON (SALES TAX)

ARTICLE 4 AS AMENDED

FUNDAMENTALS OF POWER DISTRIBUTION SAIEE-1337-V : 2 CPD credits : Category 1

ARTICLE 9 AS AMENDED

ADDENDUM #1. A. Alternate Bid Item #3A - The procurement and installation of a new 12,000 gallon UL 2085 rated AGT tank for

EE 741 Over-voltage and Overcurrent. Spring 2014

MPC-20 Software Configuration Tool Guide

Sectionalizing. Rick Seeling. Pete Malamen. Introduction Philosophy. Three Phase Reclosers High-Side Protection Specific Applications

Apricus Australia Commercial Hot Water Warranty

Pretest Module 29 High Voltage Unit 1

MAHALAKSHMI ENGINEERING COLLEGE TIRUCHIRAPALLI

Resilience in Energy: Building Infrastructure Today for Tomorrow s Automotive Fuel

ISO Rules Part 500 Facilities Division 502 Technical Requirements Section Interconnected Electric System Protection Requirements

Chapter 6 Generator-Voltage System

VOLUME: IIIC SCHEDULE IIIC/4 11 KV AND 3.3 KV SWITCHGEARS

2014 ELECTRICAL TECHNOLOGY

Power systems Protection course

UNIT-I ALTERNATORS PART-A

Circuit Breaker Prepared By :

2-marks question bank UNIT I - TRANSFORMERS UNIT II: AC MACHINES

33 KV STATIC SHUNT CAPACITOR WITH ALLIED EQUIPMENT

TECHNICAL MANUAL ORGANIZATIONAL, DIRECT SUPPORT, AND GENERAL SUPPORT MAINTENANCE MANUAL WITH REPAIR PARTS AND SPECIAL TOOLS LIST

ELECTRICAL INSTALLER THEORY EXAMINATION 21 June 2014 QUESTION AND ANSWER BOOKLET

Contents. Chapter No. Title Page No. 1 Overview of a Ship s Electrical System 1. 2 Electrical Safety 41

TABLE OF CONTENTS. About the Mike Holt Enterprises Team... xviii CHAPTER 1 ELECTRICAL THEORY... 1

HARYANA VIDYUT PRASARAN NIGAM LTD.

DESIGN CONSIDERATIONS FOR APPLICATION OF SHUNT CAPACITORS IN HEAVY HATER PLANT (TUTICORIN)

Power Systems Trainer

INESING srl. MOBILE SUBSTATIONS Energy Solution. Energy Innovation. INESING srl Energy Innovation

1.0 Scope. 2.0 Codes and Standards

LIFE INSURANCE CORPORATION OF INDIA

A REPORT ON. Undertaken at

Unit III-Three Phase Induction Motor:

R07 SET - 1

Regulation: R16 Course & Branch: B.Tech EEE

Scheme - I. Sample Question Paper

532: 2006 Bicycle tube valves and valve tubing Specification (third revision) 2414: 2005 Cycle and rickshaw pneumatic tyres (fourth revision)

Syllabus for the Trade of Electrician Duration : Six Month Second Semester Semester Code: ELE: SEM II

CHAPTER 4 PROTECTION REQUIREMENTS

SHRI ANGALAMMAN COLLEGE OF ENGINEERING AND TECHNOLOGY (An ISO 9001:2008 Certified Institution) SIRUGANOOR, TIRUCHIRAPPALLI

DEPARTMENT OF ELECTRICAL AND ELECTRONICS ENGINEERING

School of Electrical and Information Engineering. ELEC High Voltage. University of Sydney. Dr Keith Mitchell. Engineering

GUWAHATI MUNICIPAL CORPORATION WATER WORKS :: PANBAZAR GUWAHATI

UBC Technical Guidelines Section Edition Commissioning of Electrical Systems Page 1 of 5

Title Electrical Technical Maintenance Coding System. Reference Number PMP 01 (RIC Standard: EP SP)

Oil Circuit Breakers

AE105 PRINCIPLES OF ELECTRICAL ENGINEERING JUNE 2014

Protective Device Coordination ETAP Star

FATIMA MICHAEL COLLEGE OF ENGINEERING & TECHNOLOGY Senkottai Village, Madurai Sivagangai Main Road, Madurai

3.2. Current Limiting Fuses. Contents

SF 6 gas insulated RMU SafePlus 24 kv. ABB SafePlus 24 kv SF6 gas insulated RMU 1

Name and address of DISCOM with Logo. TARIFF NOTIFICATION The 22 rd March, 2018 RETAIL SUPPLY TARIFF EFFECTIVE FROM 1 st APRIL, 2018

COLLEGE OF ENGINEERING DEPARTMENT OF ELECTRICAL AND ELECTRONICS ENGINEERING QUESTION BANK SUBJECT CODE & NAME : EE 1001 SPECIAL ELECTRICAL MACHINES

Course Semester Subject Code Subject Name B.E EEE(M) V UAEE507 MARINE ELECTRICAL TECHNOLOGY UNIT-I

NATIONAL CERTIFICATE (VOCATIONAL) ELECTRICAL SYSTEMS AND CONSTRUCTION NQF LEVEL 4 NOVEMBER 2009

ELECTRICIAN S THEORY EXAMINATION 11 September 2010 QUESTION AND ANSWER BOOKLET

Study of Fault Clearing by A Circuit Breaker In Presence of A Shunt Capacitor Bank

Characteristics of LV circuit breakers Releases, tripping curves, and limitation

QUESTION BANK III YEAR / V SEM CONTROL OF ELECTRICAL MACHINES UNIT I CONTROL CIRCUIT COMPONENTS PART - A

Northeastern Rural Electric Membership Corporation Schedule DG-2 Columbia City, Indiana Page 1 of 5

Unit AE01K Knowledge of Locating and Correcting Simple Electrical Faults in the Automotive Workplace

EE042: Practical Power System Protection for Engineers & Technicians

DC CIRCUITS ELECTROMAGNETISM

KENYA POWER-MOMBASA BRANCH REPLACEMENT OF AIR-CONDITIONING AND ASSOCIATED WORKS BILLS OF QUANTITIES FOR ELECTRICAL INSTALLATIONS BILL NO

Medium Voltage Standby non-paralleling Control GUIDE FORM SPECIFICATION

SF 6 Gas Insulated Switchgear Type SDH714 for 72.5 to 145 kv

NATIONAL CERTIFICATE (VOCATIONAL) ELECTRICAL SYSTEMS AND CONSTRUCTION NQF LEVEL 3 NOVEMBER 2009

Transformer Protection

ELECTRICAL INSPECTOR EXAMINATION 14 November 2015 QUESTION AND ANSWER BOOKLET Time Allowed: Three hours

DEPARTMENT OF ELECTRICAL ENGINEERING DIT UNIVERSITY HIGH VOLTAGE ENGINEERING

QUESTION BANK SPECIAL ELECTRICAL MACHINES

SYLLABUS. osmania university UNIT - I UNIT - II UNIT - III UNIT - IV CHAPTER - 1 : PRINCIPLES OF ELECTRO-MECHANICAL ENERGY CONVERSION CHAPTER - 2 :

Amendments in Technical Specification No. S-137/DD-177 July 2007 for 11KVAutomatic Switched Capacitor bank at Sub-Stations (33/11KV).

ELECTRICIAN S THEORY EXAMINATION 21 June 2014 QUESTION AND ANSWER BOOKLET

TECHNICAL MANUAL OPERATOR'S, ORGANIZATIONAL, DIRECT SUPPORT, and GENERAL SUPPORT MAINTENANCE MANUAL (INCLUDING REPAIR PARTS AND SPECIAL TOOLS LIST)

In any of the 5 star hotels. The exact venue will be informed once finalized.

COURSE OUTLINE (Page 1 of 9)

Catalog HA Edition up to 24 kv, Air-Insulated, Extendable. Medium-Voltage Switchgear. siemens.com/simosec

Advanced Protective Relay Training


Fuse Link Designation

Pretest Module 29 High Voltage

Diagnostics of Rotor and Stator Problems in Industrial Induction Motors

Higher Secondary Level (Grade XI & XII) 2015 Electrical Engineering

HVACR Electrical Systems

EE6401 ELECTRICAL MACHINES I UNIT I: MAGNETIC CIRCUITS AND MAGNETIC MATERIALS PART: A 1. Define EMF and MMF. 2. Name the main magnetic quantities

ANALYSIS OF OVERCURRENT PROTECTION RELAY SETTINGS OF A COMMERCIAL BUILDING NURUL SYAQIRAH BINTI MOHD SUFI UNIVERSITI MALAYSIA PAHANG

CENTRAL MARKS DEPARTMENT II (Legal) Our Ref: CMD-II(L)/16:

Chapter 3.1: Electrical System

34 th Hands-On Relay School

Table of Contents. CHAPTER 1 BASIC ELECTRICAL THEORY (Essential for Journeyman and Master s Licensing Exams)... 1

METEOROLOGICAL TABLES,

Outdoor live tank SF6 circuit breaker EDT with integrated current transformer up to 72.5 kv

Transcription:

Question Set(2017) Switch Gear & protection(5 th SEm) 1. What is fault in power system? Classify the fault. What are the bad effects of fault? 2. Define with example: Symmetrical fault and unsymmetrical fault. 3. What is reactor? Classify the reactor. Describe briefly any one from them. 4. What do you understand by percentage of reactance? Do the related problems regarding short circuit and base kva calculation. 5. What is circuit breaker? Classify the circuit breaker? 6. Define the following terms: Breaking capacity, making capacity, Arc voltage, Restriking voltage, Recovery voltage, R.R.R.V, 7. Explain the phenomenon of arc in CB 8. Explain the different method of arc excitation. 9. Explain the construction and operating principle with proper diagram: MOCB ABCB SF6 Vacuum circuit Breaker (v) state their advantage and disadvantage 10. Write short notes on: Operating mechanism of CB Auto reclosing MCB ELCB or RCCB 11. What is fuse? What are the desirable characteristics of fuse? Name the materials used in fuse element. 12. Define the following terms: (v) (vi) (vii) Current rating of fuse element Fusing current Fusing factor Prospective current Cut-off current Pre-arcing time Arcing time

(viii) Total operating time 13. Explain the construction and operating principle of HRC fuse with suitable diagram. Also state the application. 14. State the advantage and disadvantage of HRC fuse. 15. What are the considerations in selecting fuse for Motor protection Transformer protection 16. Distinguish between the function of Isolator Circuit Breaker Earthing switch 17. State the sequence of operation of circuit breaker, isolator and earthing switch 18. What are the Difference between fuse and MCB? 19. State the causes of over voltage in power system. How transmission line is protected from over voltage? 20. What is protective ratio and protective angle? How the tower footing resistance can be reduced? 21. What is surge absorber and surge diverter? 22. write short notes on: Rod gap Horn gap Metal oxide arrestor(moa) Ferranti surge absorber 23. What are the various methods used to protect transmission line against lightning? 24. Describe the methods of protection of substation against damage due to lightning stroke. 25. Describe primary and back-up protection. 26. Explain briefly the purpose of zone of protection. 27. What are the main characteristics of protective relays? 28. Describe briefly on following relays: i) Inverse time relays ii) iii) iv) Definite time lag relay Instantaneous relay Differential relay. 29. Define the following terms: Pick-up current Current setting P.S.M. Time setting multiplier

30. Describe the construction and operating principle: Induction type over current relay (non directional) Induction type directional over current relay distance relay or impedance relay Transley system relay 31. Write short notes on: CVT CCVT Electro-magnetic relay Thermal relay (v) Static relay 32. State the principle of CT & PT in a protection system. Draw a neat circuit diagram incorporating CT & PT in a protection system. 33. A 10 Amp 3 sec. o/c relay has current setting of 150% and TSM of 0.5, the relay is connected in the circuit through CT having ratio of 500/5. Calculate the time of operation of relay if the circuit carries a fault current of 6000 amps. The relay has the following characteristics: P.S.M 3 4 5 6 7 8 9 10 7 5.5 5 4 3.8 3.5 3.1 3 Time in sec 34. write short notes on: Differential protection of bus-bar Fault bus protection Radial feeder protection Parallel feeder protection (v) Ring main system protection 35. State the field application of buchholz relay. Explain its working principle with diagram. 36. What is meant by distance relay? With the neat sketch explain the operation of impedance relay. 37. Describe with a neat sketch the differential protection of stator winding fault of an alternator. 38. Write short notes on Earth fault protection of transformer.

39. A 3 phase 33/6.6 kv star/delta connected transformer is protected by merz-price circuiting system. If the ct is on low voltage side have a ratio of 300:5, determine the ratio of CTs on the high voltage side. 40. What is meant by zone of protection? With simple diagram show such a scheme of protection for transmission line and describe its principle of operation. 41. Mention the various methods of protection required for the protection of alternator. 42. What do you meant by motoring action and field suppression of an alternator? 43. Explain the operation of differential protection of an alternator and transformer. SHORT QUESTION(Each carry 2 marks) 1. What is circuit breaker? 2. Classify the circuit breaker. 3. What is the purpose of oil in OCB? 4. What is SF6? 5. What is the disadvantage of SF6 gas? 6. What are the important of rating of circuit breaker? 7. What is breaking capacity? 8. What is making capacity? 9. Write two properties of SF6. 10. What is recovery voltage? 11. Define RRRV. 12. Define Restriking voltage in CB. 13. Write any two advantage of SF6 in CB. 14. What are the methods of arc interruption in CB? 15. How does a circuit breaker differ from a switch? 16. What is meant by rupturing capacity of a circuit breaker? 17. List the essential features of a switch gear. 18. A 3 phase oil circuit breaker is rated at 1200V, 13000MVA and 11 kv. Find the rated symmetrical breaking current and rated making current. 19. Draw the symbol of: Circuit Breaker (v) (vi) (vii) Isolator Earthing Switch Surge Arrestor C.T. P.T. Surge absorber

(viii) Ferranti surge absorber 20. What is meant by burden of a relay? 21. What is meant by back-up relay? 22. What is meant by back-up protection? 23. State the essential qualities of protection? 24. Mention the percentage of occurance of different types of faults on over head line 25. List the percentage of distribution of faults in the various power system element 26. Define protective relay 27. Define: Operationg torque, Restriking torque, 28. Define: Pick-up current, P.S.M,T.S.M, Fault clearing time, Breaker time, Relay time 29. What is static relay? 30. What are essential qualities of a relay? 31. What are the various Time-current characteristics of an over current relay? 32. What is auto re-closure? 33. What is plcc? 34. What is meant by a polarized relay? 35. What is time grading of relay? 36. What is meant by directional relay? 37. What are the applications of over current relay? 38. What is differential relay? 39. What are the applications of differential relay? 40. What is a comparator? 41. What are the types of comparator? 42. What are the faults of alternator? 43. Why the loss of excitation occurs in the alternator? 44. Draw the block diagram of a static relay? 45. What are the advantage and disadvantage of static relay? 46. What is Buchholz relay? Where it is used? 47. Draw the block diagram of a basic static distance relay? 48. Why the secondary of a C.T. should not be opened? 49. What is need for power system earthing? 50. What is meant by 5p20:10VA? Fill in the blanks by inserting appropriate words: A fuse is a... device. A circuit breaker is a... device. An isolator is designed to open a circuit breaker under... When a switch is opened,... is produced.

(v) Under normal operation conditions, the contacts of the circuit breaker remain... (vi) Under fault conditions,... supplies information to the circuit breaker to open. (vii) For greater flexibility,... bus-bar system is used. (viii) The outdoor type switchgear is generally used for voltage beyond,... kv. (ix) When a short circuit occurs, a... current flows through the system. (x) When all the three phases are short-circuited, it gives rise to... currents. (xi) The rating of circuit breaker is generally determined on the basis of... short circuit current. (xii) The most common type fault in the overhead lines is... (xiii) A 1000kVA transformer with 5% reactance will have a reactance of... at 2000kVA base. (xiv) Short circuit kva is obtained by multiplying the base kva by... (xv) Reactors are used at various points in the power system to... (xvi) A fuse element should have... melting point. (xvii) The value of fusing factor is always... than unity. (xviii) A fuse has... time current characteristics. (xix) The fuse element is generally made of... (xx) A fuse performs... functions. (xxi) A fuse has... breaking capacity as compared to a circuit breaker. (xxii) A relay performs the function of... (xxiii) The relay operating coil is supplied through... (xxiv) A 1vA relay is... sensitive than a 3vA relay. (xxv) The minimum relay coil current at which the relay operates is called... (xxvi) Induction relays... be used with dc quantities. (xxvii) An over current relay having a current setting of 125% is connected to a supply circuit through a current transformer of ratio 400/5. The pick-up value will be... (xxviii) The pick-up value of a relay is 7.5A and fault current in relay coil is 30A. Its plugsetting multiplier is... (xxix) Back-up protection will be activated when... (xxx) Induction relays are used with... quantities. (xxxi) Back up protection is generally employed for protection against... faults. (xxxii) The most commonly used system for the protection of generator is... (xxxiii) Automatic protection is generally... provided for field failure of an alternator. (xxxiv) The chief cause of over speed is an alternator is the... (xxxv) Buchholz relay is installed between... and conservator. (xxxvi) For the protection of a delta/star power transformer, the CTs on delta side must be connected in... (xxxvii) Overload protection is generally not provided for...

(xxxviii) Buchholz relay is a... relay. (xxxix) The most important stator winding fault of an alternator is... fault. (xl) Merz-Price circulating current principle is more suitable for... than... (xli) The most severe surge on the line are produced by... (xlii) Lightning produces a... fronted wave. (xliii) For successful working of ground wire, the footing resistance of tower should be... (xliv) A surge diverter should be located... to the apparatus to be protected. (xlv) Most of the lightning strokes are due to... charge clouds. (xlvi) The stroke A will always occur on... (xlvii) Surge absorbers are used to... the steepness of wave front of the surge. www.electricaledu.com