Extracting Valuable Information from HV Circuit Breaker Testing. Charles Sweetser - OMICRON MIPSYCON 2014

Similar documents
A Systematic Approach to High-Voltage Circuit Breaker Testing

Close-Open (Short-Circuit) Time Results Interpretation

Air-insulated switchgear UniGear type ZS1

Using new Magnetically Actuated Vacuum Interrupter technology for safe and reliable medium voltage circuit breaker switching in mines

Descriptive Bulletin. R-MAG TM magnetically actuated dead tank outdoor vacuum circuit breaker 15.5 kv - 38 kv

Descriptive Bulletin. R-MAG magnetically actuated dead tank outdoor vacuum circuit breaker 15.5 kv - 38 kv

The galvanic separation of the primary or actuating circuit and the load circuits

Application Note. First trip test. A circuit breaker spends most of its lifetime conducting current without any

R-MAG. Vacuum Circuit Breaker with Magnetic Actuator Mechanism

Breaker failure protection function block description

Dead Tank Circuit Breaker 145PM40-C Compact design with enhanced reliability

1.0 Installation Wiring

R-MAG Vacuum Circuit Breaker with Magnetic Actuator Mechanism 15.5 kv - 27 kv; 1200 A A

PUB NLH 174 Island Interconnected System Supply Issues and Power Outages Page 1 of 4

Horizontal Circuit Switchers

Power systems Protection course

OPERATING AND MAINTENANCE MANUAL. Primary Current Injection Test Set. 750ADM-H mk2

Solid Dielectric, Triple Option Reclosers Catalog O-vlt14

Solid Dielectric, Triple Option Reclosers Catalog O-vlt14

INESING srl. MOBILE SUBSTATIONS Energy Solution. Energy Innovation. INESING srl Energy Innovation

Outdoor vacuum breaker for railway applications - FSK II

Circuit Breaker and Transducer: Where do I connect? Robert Foster Application Engineer Megger Paradise, CA 95969

BCM application note Travel measurement in circuit breaker monitoring

Circuit breaker interlocking and operation requirements SIEMENS

September 2008 TEC, INTELLIGENT MONITORING SYSTEM

Horizontal Circuit Switchers

Publication No.: PSG

The University of New South Wales. School of Electrical Engineering and Telecommunications. Industrial and Commercial Power Systems Topic 6

The X, Y, and Z of Circuit Breaker Control

VOLUME: IIIC SCHEDULE IIIC/4 11 KV AND 3.3 KV SWITCHGEARS

Components for EEx e Panels

16kA Solid Dielectric, Triple Option Reclosers Catalog VLT12

Specification Guide. for RMVAC. Direct Replacement. AC Medium Voltage. Circuit Breakers

OHB Outdoor sulphur Hexafluoride circuit-breaker

Outdoor live tank SF6 circuit breaker EDT with integrated current transformer up to 72.5 kv

1. Take the cover off the relay, taking care to not shake or jar the relay or other relays around it.

Pretest Module 29 High Voltage Unit 1

Motor Protection Fundamentals. Motor Protection - Agenda

Medium Voltage Outdoor Apparatus Portfolio 2009

Advance 27 ANSI 27 kv switchgear

Contactor V-Contact VSC/P

Solid Dielectric, Single Phase Recloser

MV Air Insulated Switchgear TAP17. Technical Data TGOOD

CITY OF LOMPOC UTILITIES DEPARTMENT ELECTRICAL DIVISION SPECIFICATION NO. ELE-112 SUBSTATION CLASS VACUUM CIRCUIT BREAKERS OCTOBER 2008

Instruction manual. Type 3AH35-MA vacuum circuit breaker magnetic-actuator operator module.

Instruction manual. Type 3AH35-MA vacuum circuit breaker magnetic-actuator operator module.

Dynamic Resistance Measurement for Circuit Breakers Applying high DC current

Type SDV7 distribution circuit breaker family Answers for energy.

GE Electrical Distribution. Gerapid High Speed DC Circuit Breakers. On the move. imagination at work

Type SOQ Negative Sequence Time Overcurrent Relay

SafeGear TM Motor Control Center Arc resistant metal-clad construction Motor Control Center Descriptive bulletin

AMVAC TM technical guide Vacuum circuit breaker with magnetic actuator mechanism

Application Note. Common Bussing AC Drives. For 650 and 690+ series drives APP-AC-03

A Revolution in Circuit Breaker Operating Mechanism Technology

REFERENCE CP_TSSPEC_138 0 DATE: JUNE 2006 PAGE: 1 OF 17 TITLE SPECIFICATION FOR POLE- MOUNTED AUTO-RECLOSERS TABLE OF CONTENTS

Multi Processing Station with Oven 24V

GE CONSUMER & INDUSTRIAL

2.1 Warnings & Agency Approvals Electrical Connections - Specifications Standard Wiring Configurations...2 4

Solid Dielectric, Three Phase Reclosers Catalog O-vs18

Transmission Switching

Medium Voltage Test Report Job Number Job Information. Test Information. Circuit Breaker Information. Electric Power Systems

SUBSTATION VACUUM CIRCUIT BREAKER (38KV)

Circuit Breakers. Switching & Controls. Selection Guide NC1V Series Dimensions...

PRODUCT / TEST MANUAL 2C58K2 INSTANTANEOUS OVERCURRENT

SUBSTATION VACUUM CIRCUIT BREAKER (15.5KV)

ISO Rules Part 500 Facilities Division 502 Technical Requirements Section Interconnected Electric System Protection Requirements

SUBSTATION VACUUM CIRCUIT BREAKER (25.8 / 27KV)

SION Vacuum Circuit-Breakers. Answers for energy. Medium-Voltage Equipment Selection and Ordering Data. Catalog HG

ABB ! CAUTION. Type KRV Directional Overcurrent Relay E 1.0 APPLICATION 2.0 CONSTRUCTION AND OPERATION. Instruction Leaflet

Type SDV7 distribution circuit breaker family

DIP SWITCH BASED EARTH LEAKAGE RELAY (ELR) WITH CORE BALANCE CURRENT TRANSFORMER (CBCT / ZCT) EL SERIES

Product Specification Guide. Title: Southern States 72 kv RLSwitcher Vertical Interrupter Style Reactor Switcher

SWITCHGEAR FOR SERVICE UP TO 36kV (CABLE AND OVERHEAD CONDUCTOR CONNECTED)

MOTOR TERMINAL CONNECTIONS

UBC Technical Guidelines Section Edition Commissioning of Electrical Systems Page 1 of 5

Eaton s Cooper Power Systems catalog Medium-voltage vacuum circuit breakers

Published in A R DIGITECH

Circuit Breakers. Switching & Controls. Selection Guide NC1V Series Dimensions Accessories

MOBILE SUBSTATION DESIGN Brad Bozich & Vitor Vieira 2755 Northwoods Parkway Norcross, Georgia

ABB Automation, Inc. Substation Automation & Protection Division Coral Springs, FL Allentown, PA

COM Overcurrent Relay

A manufacturer s view of bushing reliability, testing and analysis. Lars Jonsson Håkan Rudegard

4.0 OPERATION Type ITH-T Relay

ZENSOL AUTOMATION INC.

Solid Dielectric, Three Phase Reclosers CATALOG VS11

ABB Automation & Power World: April 18-21, 2011 EPO How 38kV R-MAG Can Be Used in Wind Farm Applications. ABB Inc. April 20, 2011 Slide 1

3AK OPERATING INSTRUCTIONS. Vacuum circuit-breaker module 3AK1 and 3AK3

Functions provided by measuring relays in railway equipment

Vacuum Circuit Breaker Type VAD-3

Contents. DX Ignition Page 2

Prüffeld der Schaltwerke

Programming of different charge methods with the BaSyTec Battery Test System

SIEMENS Transmission and Distribution

Type SDV6 distribution circuit breaker. Top performance - proven reliability. Answers for energy.

Outdoor live tank vacuum circuit breaker Type OVB-VBF for 24/36/40.5 kv applications

SDV7. Outdoor distribution circuit breaker family 15.5 kv to 38.0 kv. usa.siemens.com/sdv7

CX-Series. Circuit Breaker

B kv Gas-insulated Substations

Three-Phase Pole Mounted Recloser

TECHNICAL DESCRIPTION

Transcription:

Extracting Valuable Information from HV Circuit Breaker Testing Charles Sweetser - OMICRON MIPSYCON 2014 5 November 2014

FINEPOINT 2

Agenda Topics SF6 and Oil Breaker Types (Info) Timing and Travel Power Factor Contact Resistance (Static and Dynamic) Minimum Pick-Up

Circuit Breaker Testing Protocol Performance Characteristics Timing and Travel Command Coil Analysis Motor Current Analysis Insulation Components Gas, Oil, and Vacuum Contact Resistance Supplies and Battery System Bushings CTs

Performance Characteristics Timing and Travel O, C, TripFree CO, ReClose O-C, O-CO Command Coil Analysis Current Signature Minimum Pick-Up Motor Current Analysis

Failure Modes Major Problems May Include: Insulation Failure Failure to Operate Failure to Interrupt Catastrophic Failure Other Problems May Include: Slow Close Slow Open

Types of Breakers Oil SF6 Gas Air: Blast or Magnetic Vacuum Common Components Contacts Mechanism Insulation Arc Mitigation Control Cabinet OMICRON

Circuit Breaker Types

9

Live Tank vs Dead Tank

11

Typical Breaker Components Mechanism Springs Hydraulic Pneumatic Magnetic Actuator Contacts Moving Stationary OMICRON

Principle of Operating Mechanisms

Principle of Operating Mechanisms

Spring Mechanism Close spring is bigger than Open spring While closing open spring must be fully charged OMICRON

Spring Mechanism Close spring is bigger than Open spring

Hydraulic Mechanism

Magnetic Actuator OMICRON

MA Field Prep OMICRON

MA Testing Advanced Tests Recommended 1. Main Contact Timing (O, C, CO, O-C) 2. Contact Resistance 3. Monitoring (USP) Magnetic Actuator Function Storage Capacitor Function Capacitor Charger Function OMICRON

Actuator Current via OMICRON Current Probe OMICRON

Capacitor Connections OMICRON

Main Contact Connections OMICRON

Analyzing the Measurement OMICRON

Circuit Breaker Summary BREAKER TYPES Dead Tank Breaker (OCB) Dead Tank Breaker SF6 Live Tank Air Blast Live Tank SF6 Vacuum Breakers Air Magnetic Low Voltage Air Blast Reclosers Circuit Switchers Sectionalizers MECHANISM TYPES Hydraulic Pneumatic Spring Magnetic Actuator INSULATION SYSTEMS Oil SF6 Air Vacuum

Coil Current [A] Spring Type Operating Mechanism Open/Close Coil Principle Close Coil Magnetic Arm Open Coil Spring Coil Open Spring Core Close Spring 2.5 2 1.5 1 0.5 Source: ABB, [RUS07] 0 0 50 100 Time [ms] OMICRON

Trip Command US Typical Trip Command Duration - 66.6 ms Trip Coil Close Coil Delay OPEN (O) 66.6 ms (4 cycles) CLOSE (C) 133.3 ms (8 cycles) TRIPFREE (CO) Standing 133.3 ms (8 cycles) 8.3 ms (1/2 cycle) RECLOSE (OC) 66.6 ms (4 cycles) Standing 300.0 ms 29

Close Command US Typical Close Command Duration 133.3 ms Trip Coil Close Coil Delay OPEN (O) CLOSE (C) 66.6 ms (4 cycles) 133.3 ms (8 cycles) TRIPFREE (CO) Standing 133.3 ms (8 cycles) 8.3 ms (1/2 cycle) RECLOSE (OC) 66.6 ms (4 cycles) Standing 300.0 ms OMICRON 30

TripFree US Typical Delay Close Command Trip Command Close Duration 133.3 ms Trip Duration Standing Delay ½ Cycle or 8.3 ms OMICRON 31

ReClose US Typical Delay Trip Command Close Command Trip Duration 66.6 ms Close Duration Standing Sometimes > 300 ms OMICRON 32

Circuit Breaker Timing and Travel Perform a Measurement -Contacts, Coils, Mechanism, Aux Switches Interpret performance characteristics Consult manufacturers specifications (Pass or Fail),unlike power factor testing

Timing and Travel What Can be Measured? 1. Displacement (Travel&Velocity) 2. Breaker State (O:R:C) 3. Coil Current 4. Battery Voltage Level 5. Auxiliary Contact State

Performance Characteristics 1. Main Contact Timing 2. Resistor Switch Timing 3. Delta Timing 4. Velocity 5. Total Travel 6. Over Travel 7. Rebound 8. Stroke 9. Contact Wipe 10. Dwell Time (TripFree CO) 11. Dead Time (ReClose OC)

Specification Example Identification Control Circuit Open Control Circuit Close Opening Time Opening Velocity Pole Spread Open Closing Time Closing Velocity Pole Spread Close Overtravel Rebound Stroke Dwell Time Reclose Time (Dead Time) CB1 70-140 VDC / 6.0 A 90-140 VDC / 6.0 A 17-30 ms 3.8 m/s minimum 2.7 ms 50-85 ms 1.7 to 2.3 m/s 2.7 ms 4.0 mm maximum 6.5 mm maximum 113 mm maximum 20-38 ms 300 ms minimum

Measured Values

Main Contact Timing

Resistor Switch Timing

Pole Spread (Delta)

Travel CLOSE

Contact Wipe Contact Wipe: The distance the contacts move during a close operation from first make to the final resting position. This is an electrical measurement.

Insulation Components Overall Power Factor -TLI Tank Loss Index (OCB) Insulation Resistance DGA and Oil Screen (OCB) SF6 Moisture, Density, and SO2

OCBs vs Dead Tank SF6

OCB Test Procedure Test Insulatio n Tested Breaker Position HV IN A IN B Test Mode 1 C 1G Open Bushing 1 - - GST 2 C 2G Open Bushing 2 - - GST 3 C 3G Open Bushing 3 - - GST 4 C 4G Open Bushing 4 - - GST 5 C 5G Open Bushing 5 - - GST 6 C 6G Open Bushing 6 - - GST 7 C 1G +C 2G Closed Bushing 1&2 - - GST 8 C 3G +C 4G Closed Bushing 3&4 - - GST 9 C 5G +C 6G Closed Bushing 5&6 - - GST NOTE: All unused bushing should be left floating

Tank Loss Index (TLI) TLI = (closed breaker test in watts) (sum of open breaker losses in watts) Negative TLI (-) Lift Rod Guide Interrupter Assembly Positive TLI (+) Lift rod Oil Tank Liner

Dead Tank SF6 Test Procedure Test Insulatio n Tested Breaker Position HV IN A IN B Test Mode 1 2 3 4 5 6 7 8 9 10 11 12 C 1G C 2G C 3G C 4G C 5G C 6G C 12 C 34 C 56 C 1G +C 2G C 3G +C 4G C 5G +C 6G Open Bushing 1 - - GST Open Bushing 2 - - GST Open Bushing 3 - - GST Open Bushing 4 - - GST Open Bushing 5 - - GST Open Bushing 6 - - GST Open Bushing 1 Bushing 2 - UST-A Open Bushing 3 Bushing 4 - UST-A Open Bushing 5 Bushing 6 - UST-A Closed Bushing 1&2 - - GST Closed Bushing 3&4 - - GST Closed Bushing 5&6 - - GST NOTE: All unused bushing should be left floating

Power Factor

Power Factor

Contact Resistance Static Contact Resistance Current Level CB1 PHASE A PHASE B PHASE C 100 A 77.93 µ 78.39 µ 79.08 µ 200 A 77.93 µ 78.44 µ 79.15 µ 300 A 78.00 µ 78.43 µ 79.19 µ 400 A 78.00 µ 78.46 µ 79.19 µ IEEE C37.09 - DC test current of 100 A minimum and not exceeding rated current Dynamic Contact Resistance Closed position Arcing Open position 2 Stationary arcing contact 7 Stationary main contact 3 Moving arcing contact 8 Moving main contact

Dynamic Contact Resistance

Minimum Pick-Up Determine the command coil parameters and ratings, AC or DC, and operating voltage. Determine a start and stop voltage for the command coil under test. Example, 125 VDC command coil, Start [10 VDC] Stop [125 VDC] Determine pulse time: the pulse time should be limited so the command coil does not overheat, 300 ms is the default starting point. Determine dead time: this is the time that the command coil pauses between pulses. The dead time should be long enough to assist is cooling of the command coil. 2 seconds is a reasonable starting point. Determine the voltage step increment: This is the amount that the voltage is increased between command coil pulses: 5 VDC is a reasonable starting point.

Minimum Pick-Up

Other Terminology and Applications 1. First Trip 2. Slow Close 3. Minimum Pick-Up 4. Minimum Voltage OMICRON

OMICRON QUESTIONS?