LCN AUTOMATIC OPERATORS

Similar documents
Senior Swing Control Box. Table of Contents

*PULL SIDE mount shown

SENIOR SWING UNIQUE FEATURES

LCN 9540 SERIES SINGLE DOOR, SURFACE MOUNT (PUSH) OFFSET PIVOT/BUTT HINGE

9550 SERIES FEATURES OPERATOR MOUNTS SIMULTANEOUS PAIR, SURFACE MOUNT *PULL SIDE PUSH SIDE DOUBLE EGRESS

9540 SERIES FEATURES SINGLE DOOR, SURFACE MOUNT (PUSH) OFFSET PIVOT/BUTT HINGE

*CENTER PIVOT arm shown

LCN 9740 SERIES SINGLE DOOR, SURFACE MOUNT (PUSH) OFFSET PIVOT/BUTT HINGE

9550 Series Senior Swing. Features. Special Templates. Certifications. Fasteners Mounting

9560 Series Senior Swing. Features. Special Templates. Cover Fasteners Mounting. Certifications

LCN 2810 SERIES OPERATOR MOUNTS SINGLE DOOR, OVERHEAD CONCEALED CENTER PIVOT ARM OFFSET PIVOT/BUTT HINGE

*70954* 240V Senior Swing Control Box Installation Instructions CAUTION WARNINGS. Table of Contents

9530 Series Senior Swing. Features. Special Templates. Fasteners Mounting. Certifications

*CENTER PIVOT arm shown

2860 SERIES FEATURES OPERATOR MOUNTS INDEPENDENT PAIR, OVERHEAD CONCEALED *CENTER PIVOT OFFSET PIVOT/BUTT HINGE

2850 Series Senior Swing. Features. Special Templates. Certifications. Fasteners Mounting

9550 SERIES FEATURES OPERATOR MOUNTS SIMULTANEOUS PAIR, SURFACE MOUNT *PULL SIDE PUSH SIDE DOUBLE EGRESS

LCN 9140 SERIES FEATURES SINGLE DOOR, SURFACE MOUNT (PUSH) OFFSET PIVOT/BUTT HINGE

LCN 9130 SERIES FEATURES SINGLE DOOR, SURFACE MOUNT (PULL) OFFSET PIVOT/BUTT HINGE

9140 SERIES FEATURES SINGLE DOOR, SURFACE MOUNT (PUSH) OFFSET PIVOT/BUTT HINGE

Electrohydraulic Powered Systems

Electro-Mechanical Swing Operator. Table of Contents

4640 shown POWER OPERATOR HOLD-OPEN ACCESSIBILITY* NON-HANDED NON-SIZED

ASSA ABLOY Series Power Operator Installation and Instruction ASSA Manual ABLOY ASSA ABLOY

Dor-O-Matic. Senior-Swing Universal Control Box. Instruction Manual Universal Control Box DOR-O-MATIC

LCN 4310ME SERIES FEATURES HINGE (PULL) SIDE MOUNTING. The 4310ME SENTRONIC is a. heavy duty, electrically controlled

LCN 4310ME SERIES HINGE (PULL) SIDE MOUNTING. The 4310ME SENTRONIC is a. heavy duty, electrically controlled. closer/holder designed to provide

ASSA ABLOY Series Power Operator Installation and Instruction ASSA Manual ABLOY ASSA ABLOY

NON-SIZED SIZED HANDED

SURFACE MOUNTED PULL SIDE

CONCEALED CLOSER SERIES

Requirements LEO Power Operator Installation Instructions Patents: 5,881,497; 7,316,096; 7,484,333 CAUTION CAUTION WARNING

CONCEALED CLOSER SERIES

FIRE/LIFE SAFETY CLOSERS/HOLDERS SERIES

Allegion LCN Benchmark AU9100 Series

FIRE/LIFE SAFETY SERIES PRODUCT SELECTION GUIDE

Dor-O-Matic. Series Slide Control. Installation Instructions

Full-featured operator with slim profile for moderate to high traffic applications LOW ENERGY OPERATOR CATALOG

Power Operators. Requirement. Approved Manufacturers. -All Operators To Be Electrically Powered -Operators To Be Aluminum (BHMA 689) Finish

KEANE MONROE a member of the record group

*29268* 4600CS Electronic Low Energy Operator 4630CS PULL SIDE MOUNT 4640CS PUSH SIDE MOUNT. Table of Contents. Customer Service

DOUBLE LEVER ARM DOUBLE LEVER ARM SINGLE LEVER ARM 5010 SINGLE LEVER ARM

Requirements LEO Power Operator Installation Instructions Patents: 5,881,497; 7,316,096; 7,484,333 CAUTION CAUTION WARNING

LCN 4010T SERIES HINGE (PULL) SIDE

4310ME Series. Features E25. Special Templates. Grade 1 - ANSI A156.15, UL 10C, ADA, 100 Hour Salt Spray, Meets BAA - Buy American Act, NFPA 101

HIGH SECURITY CLOSERS SERIES

*28101* 4600 Electronic Low Energy Operator Installation Instructions 4630 PULL SIDE MOUNT 4640 PUSH SIDE MOUNT. Table of Contents.

AUTOMATIC OPERATORS SURFACE MOUNTED PULL SIDE

NON-SIZED SIZED HANDED

LCN 4040SE SERIES FEATURES HINGE (PULL) SIDE MOUNTING

5600 Series Power Operator Installation and Instruction Manual

HIGH SECURITY SERIES

Dor-O-Matic. Astro Swing Universal Control Box. Instruction Manual Universal Control Box

4310ME Series. Features E25. Special Templates. Certifications. Cover Fasteners Mounting Arms

T57 SERIES LOW ENERGY OPERATOR INTRODUCTION FEATURES BENEFITS PATENTS TABLE OF CONTENTS

AL(689) DKBRZ(695) DKBRZ(695) LTZPC(691) AL(689) DKBRZ(695) AL(689) DKBRZ(695)

*HINGE (pull) side mount shown

6900 Series PowerMatic Low Energy Power Operator

6900 Series PowerMatic. Low Energy Power Operator

Electrified Products TABLE OF CONTENTS. P Power Supply Power Transfers Pressure Sense Bars Proximity Cards & Keys...

Electrified Products TABLE OF CONTENTS. P Power Supply Power Transfers Pressure Sense Bars Proximity Cards & Keys...

MOUNTING FINISH COVER CYLINDER **ARM FUNCTION REGULAR (DOUBLE) DESIGNER METAL NON-HANDED NON-SIZED

4840 with EDA arm and 459 Door Loop

NON-SIZED SIZED HANDED

High Security Closers Series

High Security Closers Series

*24771* 4040SE DE Sentronic. 1 Voltage. 7 Regulation. 2 Track. 8 Door Closer Cover. 3 Spring Power. 4 Arm Installation. 5 Arm Screw.

7800 & 7900 Powered Door Operators Premier Product

Setup and Programming Manual

Metal, Standard Wood and machine screw pack Top jamb (Push Side) Body Construction. Finishes/Colors/ Powder Coat. Wiring NON-SIZED SIZED

CRAFTMASTER HARDWARE CO., INC Architectural. Product Guide

7100SZ SERIES. Multi-Point Closer/Holder with Motion Sensor

5700 Series Power Operator Hinge (Pull) Side Mount Installation and Instruction ASSA Manual ABLOY

Adams rite. Exit Devices & parts exit devices series exit device parts

Multi-point closer/holder with motion sensor 7100SZ DOOR CLOSER CATALOG

2904 Power Supply Installation Instructions I-EA00041

PULL SIDE MOUNTED PUSH SIDE MOUNTED DOUBLE LEVER ARM LEVER ARM P DOUBLE LEVER ARM SINGLE LEVER ARM 4110T 4210T*

Recessed. Touch bar exit devices

PUSH SIDE M O U N T E D PULL SIDE M O U N T E D D O U B L E LEVER ARM LEVER ARM P D O U B L E LEVER ARM S I N G L E LEVER ARM

5700 Series Power Operator Stop (Push) Side Mount Installation and Instruction

B100S - Super Swing. Instruction Manual. Document number: B100S-C Release: V4.0 Date: May 08,2009

LCN Super Smoothie Adjustable Closer Super Smoothie Adjustable Closer

ARCHITECTURAL CONTROL SYSTEMS, INCORPORATED ST. LOUIS, MISSOURI

ED900. Low Energy Swing Door Operators

ABS-AMERICAN BUILDING SUPPLY, INC. Von Duprin

*4110 HCUSH mount shown

7100SZ Series SafeZone. Multi-Point Closer/Holder with Motion Sensor

7100SZ Series SafeZone. Multi-Point Closer/Holder with Motion Sensor

4000 Series mounted closers

ED50. Low energy automatic swing door operator. Service Manual

1000 SERIES SURFACE MOUNTED CLOSERS

5300 Series 5300 SERIES

08710/ING BuyLine 7155

Installing the gate post bracket with the cardboard arm template

ADA Compliant Solution REV

Installing the gate post bracket with the cardboard arm template

Concealed overhead closer for high-end applications DOOR CLOSERS CATALOG

ADAMS RITE. ADAMS RITE MANUFACTURING COMPANY Sliding Hardware/Exit Devices Series Turns

Dor-O-Matic. Astro-Fold Universal Control Box Instruction Manual Universal Control Box DOR - O - MATIC

Headline. Overhead Door Holders/Stops

Transcription:

LCN AUTOMATIC OPERATORS SENIOR 9530 SENIOR 9540 SENIOR 9550 SENIOR 9560 8310 ACCESSORIES

LCN ELECTROMECHANICAL POWERED SYSTEMS ELECTROMECHANICAL AUTOMATIC OPERATORS LCN s electromechanical products are designed primarily for automatic opening applications that occasionally require manual opening. A control box provides all electrical functions. These self-contained units are suitable for use on single leaf doors or pair of doors. These products combine all the control and power elements into a single operator package, only some actuators are required to complete the system. Surface mounted and overhead concealed mountings available. Available in two standard anodized finishes aluminum and dark bronze. Custom anodized finishes and custom paint is available. LOW ENERGY ELECTROMECHANICAL POWER OPERATORS Complies with ANSI 156.19 Opening time from full close to backcheck is no faster than 3 seconds Less than 15lbs of force to open door manually HIGH ENERGY ELECTROMECHANICAL POWER OPERATORS Complies with ANSI 156.10 Opening time from full close to backcheck is no faster than 1.5 seconds Less than 30 lbs of force to open door manually Requires use of guide rails and safety devices STANDARDS, LISTINGS & APPROVALS UL listed for self-closing doors without hold open. UL 325. Tested and certified under ANSI. Low Energy Electromechanical Operators ANSI 156.19 High Energy Electromechanical Operators ANSI 156.10 ADA Compliant. Applicable to Low Energy Electromechanical Operators only. Wiring is compliant with both UL 325 and the NEC. Separation of high and low voltage. Consult the factory for other listings. WARRANTY 2 year limited warranty. See General Section for complete details MAINTENANCE Low Energy Electromechanical Power Operators Operators mounted according to the LCN Installation instructions require no periodic maintenance or adjustments. Monthly, quarterly and annual visual inspections are recommended. No service contracts. High Energy Electromechanical Power Operators High energy automatic operators may require periodic maintenance and/or adjustments. Daily visual inspections are recommended to ensure proper operation of all activation and safety devices. 53 8/07

LCN ELECTROMECHANICAL POWERED SYSTEMS GENERAL ELECTRICAL DATA 1. Input power 115 volt, 3 wire, single phase, 60Hz, fused, 15 amp supply. 2. UL approved type flexible conduit is recommended for the 115 volt power line. 3. The 115 volt power supply must be a dedicated circuit from the main circuit breaker panel and must not be connected into a building lighting system operating fluorescent lights. 4. Location of conduits determined by mounting. See installation instructions for location. 2500, 2800, 2900, 9300, 9500, 9700 Series ELECTRICAL DATA 1. 120 VAC input @ 2.5 amps (2500 and 9300 Series). 2. 120 VAC input @ 2.5 amps (2800, 2900,9500 and 9700 Series). 3. 24 V AC output @ 1.5 amps (protected by self-resetting thermal fuse). 4. 24 V DC available with SO kit included. 9100 Series ELECTRICAL DATA 1. 120 VAC input @ 1 amp. 2. 17 VAC output @ 2.5 amps on premium control box. 3. 24 VDC available with SO kit included with premium control box. 58 8/07

LCN ELECTROMECHANICAL POWERED SYSTEMS This page illustrates examples of typical Electromechanical LCN systems. Please consult your local SSC representative of LCN for assistance with specific installations and material requirements. SINGLE DOOR SYSTEM (Low Energy) An Interior Door. No guide rails or safety devices. Free Swinging (or Dogged) Door. How It Works Wireless RF actuators with receiver, powered by the transformer allows for easy installation. For automatic door operation, touching either actuator signals the receiver and power operator to open the door to 90 degrees. The door is held there until the system times out. Door closes via spring return. Door opening speed, closing speed and hold open time is adjustable on the control box. If not actuated, the power operator functions as a manual door. SINGLE DOOR SYSTEMS Automatic Operator Low Voltage Wiring RF Actuator RF Actuator RF Receiver 120V Input BILL OF MATERIALS Qty. Part No. Description 1 9531 Automatic Operator (RH) 2 8310-3853WS RF Actuators 1 8310-865 RF Receiver VESTIBULE ENTRY SYSTEM (Low Energy) Exterior & Vestibule doors. Sequential Operation. No guide rails or safety devices. Controlled Access, Free Egress. How It Works This installation provides both accessibility and security for building occupants. It allows for the integration of multiple automatic operators, a card reader and electric strike. A sequencer allows sequential operation of the two automatic operators. Vestibule actuators allow single door ingress/egress from the vestibule as needed. If not actuated the power operator functions as a manual door. Note: 120V AC Input required to both operators 120V Input VESTIBULE ENTRY OPERATION Low Voltage Wiring Sequencer Automatic Operator Electric Strike Automatic Operator Low Voltage 120V Input Wall Plate Actuator Wall Plate Actuator Wall Plate Actuator Card Reader w/keypad as Exterior Actuator BILL OF MATERIALS Qty. Part No. Description 1 9542 Automatic operator (RH) 1 9531 Automatic operator (RH) 3 8310-853 Wall Plate Actuators 1 8310-849 Sequencer Other products from Von Duprin and Locknetics 54 8/07

LCN 9530 SERIES SINGLE DOOR, SURFACE MOUNT (PULL) OFFSET PIVOT/BUTT HINGE The 9530 SENIOR by LCN is an ADA door operator that is a two-inone swing door operator. SENIOR operators when activated, opens doors automatically for wheelchair access, yet allows for manual operation for regular pedestrian traffic. FEATURES Push N Go permits non-switch activation Power Boost provides additional latching force Electromechanical unit with microprocessor control Digital keypad for easy setup Meets International Building Code requirements and ANSI A156.19 UL approved for fire doors 9530 series operator is shipped with motor gearbox, control box, standard arm, header, and mounting hardware. Actuators available separately, see pages 121. Single door, surface mounted. Meets ADA requirements (power mode only). Handed product. 36 header length is standard. Specify length 33 to 49 max. Double door header available up to 98, specify other length 49 to 98 max. Consult factory regarding this option. Adjustable hold open period of 1 to 32 seconds in automatic or manual mode. 9530 Series is fully compliant with UL 325 & UL 1998 and meets the provisions of ANSI A156.19. The 9530 Series is UL listed for fire-rated applications. The 9530 Series also meets the provisions of the Americans with Disabilities Act. MOUNTING SURFACE MOUNT SINGLE DOOR SURFACE MOUNT SIMULTANEOUS PAIR SURFACE MOUNT INDEPENDENT PAIR CONCEALED SINGLE DOOR CONCEALED SIMULTANEOUS PAIR HANDED NON-HANDED CONCEALED INDEPENDENT PAIR HANDING STANDARD ANODIZED CUSTOM ANODIZED CUSTOM PAINT METAL FINISH COVER ARM FUNCTION STANDARD (SINGLE) REGULAR (DOUBLE) DOUBLE EGRESS (PUSH/PULL) OFFSET PIVOT ARM CENTER PIVOT ARM 97

LCN 9530 SERIES MOUNTING DETAILS TOP JAMB SINGLE DOOR (OFFSET PIVOT/BUTT HINGE, CENTER PIVOT, PULL) MOUNTING 48" DOOR OPENING (MAX.) OPERATOR 17 3/8 " 11 1/2 " PULL CHANEL 292 MM PULL ARM ASS'Y LEFT HAND INCOMING 2 3/4 " 70 MM OFFSET PIVOT or BUTT HINGES 6 3/4 " 171 MM 1 15/16 " 49 MM 5 3/4 " 146 MM OPERATOR 1" 25 MM 4 1/2 " 114 MM PULL ARM ASS'Y PULL CHANEL DIRECTION 1 3/4 " 44 MM INTERIOR DOOR HOLLOW METAL FRAME Suggested Installation MAXIMUM OPENING Template allows 90 degree power opening and 90 degree manual opening. Butt Hinges should not exceed 5 (127 mm) in width. Reveal should not exceed 4 (102 mm). Head Frame minimum 1 3/4 (44 mm). Face frame 6 3/4 (171 mm) total operator clearance. Top Rail minimum 2 3/4 (70 mm). Special Templates Customized installation templates or products may be available to solve unusual applications. Contact LCN for assistance. Opening & Closing Time are variable by adjustments to the electronic control box. Maximum hold open time adjustable up to approximately 32 seconds. System Diagram see AUTOMATIC OPERATORS section pages 52-54 for typical system wiring and page 55 for electrical data. Please consult your local SSC representative or LCN for assistance with specific installations and material requirements. 98

MOTOR GEARBOX MOTOR GEARBOX (STANDARD FORCE) SENIOR, 9530-3454 Driving mechanism for operator. Provides 15lbs opening force. Handed. MOUNTING BRACKET MOUNTING BRACKET 2 3/4, 9530-275 Motor gearbox mounting bracket for 2 3/4" offset pivot or butt hinge installations. Front bracket. REAR MOUNT BRACKET, 9530-3018 Motor gearbox mounting bracket. Rear bracket. ANGLED BRACKET, 9530-334-1 Mounting bracket for surface applications. CONTROL BOXES CONTROL BOX SENIOR, 9530-3462 Electronic controlling device for Senior Swing. HEADERS Header, 9530-3572HL Standard, mounting header. Single door, single operator. Specify length 30 to 49 maximum. Header, 9530-3572DD Standard, mounting header. Double door, single operator. Specify length 49 to 98 maximum. END CAPS HEADER END CAPS, 9530-334 End cap with openings for wiring. END DRESS PLATE, 9530-334-2 Metal finish end cap. LCN 9530 SERIES 3454 275 3018 344-1 3462 3572HL 3572DD 334 334-2 ACCESSORIES 99

LCN 9530 SERIES ACCESSORIES ARMS STANDARD ARM ASSEMBLY, 9530-3077PLCM Handed arm. STANDARD ARM, 9530-3077T Handed arm. Track roller not included. TRACKS TRACK 9530-3038 Standard non-handed track. TRACK END CAP 9530-73 Black plastic end caps. 3077PLCM 3077T ROLLER, 9530-3034 Quiet low friction roller assembly. INSTALLATION ACCESSORIES SPINDLE PLATE 2 3/4, 9530-11A Hides bottom of motor gearbox. Completes header box. Cutout allows for motor gearbox shaft. For 2 3/4" offset pivot or butt hinge installations. FILLER PLATE BLANK, 9530-12 Completes length of header box. (Specify Length) MOUNTING PLATE, 9530-18 Optional mounting plate for standard hollow metal door frames. Specify length 33 to 98 maximum. NOTE: The length of a universal 18 plate will need to be ordered 3 1/2 longer than the supplied header. 3038 3034 73 11A 12 18 100

LCN 9530 SERIES TABLE OF SIZES Indicates recommended range of door width for operator. Note: For all Senior Swing Series Single Door - Width per leaf 36 minimum, 48 maximum DOOR WIDTH 36" 914mm 9531 Minimum Door Width 48" 1219mm HOW-TO-ORDER 9530 SERIES OPERATORS 1. SPECIFY HAND RH LH 2. SPECIFY FINISH. Standard Anodized Finish Aluminum or Dark Bronze Operator will be shipped with: -STANDARD MOTOR GEARBOX (SF) -STANDARD CONTROL BOX (SC) -36 HEADER (36HL) -STANDARD ARM (3077T) -2 3/4 PIVOT POINT -STANDARD TRACK w/track ROLLER -MACHINE SCREW PACK Unless options listed below are selected. OPERATOR OPTIONS ORDERING INFORMATION HEADER HL (Specify length 36 to 49 ) DD (Specify length 49 to 98 ) MOUNTING PLATE Plate, (Specify Length 30 to 98 ) SPECIAL TEMPLATE ST- 101

LCN 9540 SERIES SINGLE DOOR, SURFACE MOUNT (PUSH) OFFSET PIVOT/BUTT HINGE The 9540 SENIOR by LCN is an ADA door operator that is a two-inone swing door operator. SENIOR operators when activated, opens doors automatically for wheelchair access, yet allows for manual operation for regular pedestrian traffic. FEATURES Push N Go permits non-switch activation Power Boost provides additional latching force Electromechanical unit with microprocessor control Digital keypad for easy setup Meets International Building Code requirements and ANSI A156.19 UL approved for fire doors 9540 series operator is shipped with motor gearbox, control box, regular arm, header, and mounting hardware. Actuators available separately, see page 121. Single door, surface mounted. Meets ADA requirements (power mode only). Handed product. 36 header length is standard. Specify length 33 to 49 max. Double door header available up to 98, specify other length 49 to 98 max. Consult factory regarding this option. Adjustable hold open period of 1 to 32 seconds in automatic or manual mode. MOUNTING HANDED NON-HANDED SURFACE MOUNT SINGLE DOOR SURFACE MOUNT SIMULTANEOUS PAIR SURFACE MOUNT INDEPENDENT PAIR CONCEALED SINGLE DOOR CONCEALED SIMULTANEOUS PAIR CONCEALED INDEPENDENT PAIR HANDING METAL STANDARD ANODIZED CUSTOM ANODIZED CUSTOM PAINT FINISH 9540 Series is fully compliant with UL 325 & UL 1998 and meets the provisions of ANSI A156.19. The 9540 Series is UL listed for fire-rated applications. The 9540 Series also meets the provisions of the Americans with Disabilities Act. COVER ARM FUNCTION STANDARD (SINGLE) REGULAR (DOUBLE) DOUBLE EGRESS (PUSH/PULL) OFFSET PIVOT ARM CENTER PIVOT ARM 103

LCN 9540 SERIES MOUNTING DETAILS TOP JAMB SINGLE DOOR (OFFSET PIVOT/BUTT HINGE, CENTER PIVOT, PUSH) MOUNTI Consult factory for all balance door installations. OFFSET PIVOT or BUTT HINGES OUTGOING PUSH ARM ASS'Y 17" From edge of door 2 3/4 " 70 MM OPERATOR 48" DOOR OPENING (MAX.) REVEAL 6 3/4 " 171 MM 1" 25 MM 4 1/2 " 114 MM 5 3/4 " 146 MM OPERATOR SECONDARY LINK DOOR FRAME 1 7/16 " From top of door DIRECTION DOOR EXTERIOR HOLLOW METAL FRAME Suggested Installation MAXIMUM OPENING Template allows 90 degree power opening and 90 degree manual opening. Butt Hinges should not exceed 5 (127 mm) in width. Reveal for push installations should not exceed 10 (254 mm) for REGULAR ARM and 20 (508 mm) for LONG ARM. Head Frame minimum 1 3/4 (44 mm). Face frame 6 3/4 (171 mm) total operator clearance. Top Rail minimum 2 3/4 (70 mm). Opening & Closing Time are variable by adjustments to the electronic control box. Maximum hold open time adjustable up to approximately 32 seconds. Special Templates Customized installation templates or products may be available to solve unusual applications. Contact LCN for assistance. System Diagram see AUTOMATIC OPERATORS section pages 52-54 for typical system wiring and page 55 for electrical data. Please consult your local SSC representative or LCN for assistance with specific installations and material requirements. 104

MOTOR GEARBOX MOTOR GEARBOX (STANDARD FORCE) SENIOR, 9540-3454 Driving mechanism for operator. Provides 15lbs opening force. Handed. MOUNTING BRACKET MOUNTING BRACKET 2 3/4, 9540-275 Motor gearbox mounting bracket for 2 3/4" offset pivot or butt hinge installations. Front bracket. REAR MOUNT BRACKET, 9540-3018 Motor gearbox mounting bracket. Rear bracket. ANGLED BRACKET, 9540-334-1 Mounting bracket for surface applications. CONTROL BOXES CONTROL BOX SENIOR, 9540-3462 Electronic controlling device for Senior Swing. HEADERS Header, 9540-3572HL Standard, mounting header. Single door, single operator. Specify length 30 to 49 maximum. Header, 9540-3572DD Standard, mounting header. Double door, single operator. Specify length 49 to 98 maximum. END CAPS HEADER END CAPS, 9540-334 End cap with openings for wiring. END DRESS PLATE, 9540-334-2 Metal finish end cap. LCN 9540 SERIES 3454 275 3018 344-1 3462 3572HL 3572DD 334 334-2 ACCESSORIES 105

LCN 9540 SERIES ACCESSORIES ARMS REGULAR ARM ASSEMBLY, 9540-3077 Handed arm. REGULAR LONG ARM ASSEMBLY, 9540-3077L Handed arm. 3077 3077L MAIN ARM, 9540-77 Handed arm attaches to motor gearbox. LINKAGE ASSEMBLY 15, 9540-79 Threaded rod attaches to door. Extends from main arm. LINKAGE ASSEMBLY 32, 9540-79LR Threaded long rod attaches to door. Extends from main arm. Used for reveal 10 to 20. INSTALLATION ACCESSORIES SPINDLE PLATE 2 3/4, 9540-11A Hides bottom of motor gearbox. Completes header box. Cutout allows for motor gearbox shaft. For 2 3/4" offset pivot or butt hinge installations. FILLER PLATE BLANK, 9540-12 Completes length of header box. (Specify Length) MOUNTING PLATE, 9540-18 Optional mounting plate for standard hollow metal door frames. Specify length 33 to 98 maximum. NOTE: The length of a universal 18 plate will need to be ordered 3 1/2 longer than the supplied header. 77 79 79LR 11A 12 18 106

LCN 9540 SERIES TABLE OF SIZES Indicates recommended range of door width for operator. Note: For all Senior Swing Series Single Door - Width per leaf 36 minimum, 48 maximum DOOR WIDTH 36" 914mm 9542 Minimum Door Width 48" 1219mm HOW-TO-ORDER 9540 SERIES OPERATORS 1. SPECIFY HAND RH LH 2. SPECIFY FINISH. Standard Anodized Finish Aluminum or Dark Bronze Operator will be shipped with: -STANDARD MOTOR GEARBOX (SF) -STANDARD CONTROL BOX (SC) -36 HEADER (36HL) -REGULAR ARM (3077) -2 3/4 PIVOT POINT -WOOD and MACHINE SCREW PACK Unless options listed below are selected. OPERATOR OPTIONS HEADER HL (Specify length 36 to 49 ) DD (Specify length 49 to 98 ) MOUNTING PLATE Plate, (Specify Length 30 to 98 ) ARM Long Arm (3077L) FINISH SPECIAL TEMPLATE ST- ORDERING INFORMATION 107

LCN 9550 SERIES OPERATOR MOUNTS SIMULTANEOUS PAIR, SURFACE MOUNT *PULL SIDE PUSH SIDE DOUBLE EGRESS *PULL SIDE mount shown The 9550 SENIOR by LCN is an ADA door operator that is a two-inone swing door operator. SENIOR operators when activated, opens doors automatically for wheelchair access, yet allows for manual operation for regular pedestrian traffic. Push N Go permits non-switch activation Power Boost provides additional latching force Electromechanical unit with microprocessor control Digital keypad for easy setup Meets International Building Code requirements and ANSI A156.19 UL approved for fire doors FEATURES 9550 series operator is shipped with motor gearboxes, control box, arms, header, and mounting hardware. Actuators available separately, see pages 121. Simultaneous pair, surface mounted. Meets ADA requirements (power mode only). Handed product. Pull, Push or Double Egress applications available. 72 header length is standard. Specify other length 60 to 98. Consult factory regarding this option. Adjustable hold open period of 1 to 32 seconds in automatic or manual mode. MOUNTING CONCEALED SIMULTANEOUS PAIR SURFACE MOUNT SINGLE DOOR SURFACE MOUNT SIMULTANEOUS PAIR SURFACE MOUNT INDEPENDENT PAIR CONCEALED SINGLE DOOR HANDED NON-HANDED CONCEALED INDEPENDENT PAIR HANDING METAL STANDARD ANODIZED CUSTOM ANODIZED CUSTOM PAINT FINISH 9550 Series is fully compliant with UL 325 & UL 1998 and meets the provisions of ANSI A156.19. The 9550 Series is UL listed for fire-rated applications. The 9550 Series also meets the provisions of the Americans with Disabilities Act. COVER ARM FUNCTION STANDARD (SINGLE) REGULAR (DOUBLE) DOUBLE EGRESS (PUSH/PULL) OFFSET PIVOT ARM CENTER PIVOT ARM 109

LCN 9550 SERIES MOUNTING DETAILS TOP JAMB SIMULTANEOUS PAIR (OFFSET PIVOT/BUTT HINGE, CENTER PIVOT, PUSH) MOUNTING OUTGOING PUSH ARM ASS'Y 17" From edge of door OPERATOR REVEAL OUTGOING 4 1/2 " 114 MM 6 3/4 " 5 3/4 " OPERATOR 171 MM 146 MM OFFSET 1" PIVOT 25 MM or BUTT HINGES SECONDARY LINK 2 3/4 " 70 MM 1 7/16 " From top of door DIRECTION DOOR 8'-0" DOOR OPENING (MAX.) DOOR FRAME EXTERIOR TOP JAMB SIMULTANEOUS PAIR (OFFSET PIVOT/BUTT HINGE, CENTER PIVOT, PULL) MOUNTING 4 1/2 " 114 MM 8'-0" DOOR OPENING (MAX.) 17 3/8 " 11 1/2 " 5 3/4 " 441 MM 291 MM 6 3/4 " 146 MM 2 3/4 " 171 MM 70 MM OPERATOR PULL CHANNEL OPERATOR OFFSET PIVOT 1" PULL ARM or ASS'Y BUTT 1 15/16 " 25 MM HINGES 49 MM PULL ARM ASS'Y PULL CHANNEL INCOMING INTERIOR INCOMING DIRECTION 1 3/4 " 44 MM INTERIOR DOOR MAXIMUM OPENING Template allows 90 degree power opening and 90 degree manual opening. Butt Hinges should not exceed 5 (127 mm) in width. Reveal for push installations should not exceed 10 (254 mm) for REGULAR ARM and 20 (508 mm) for LONG ARM. Reveal for pull installations should not exceed 4 (102 mm). Reveal for double egress installations should not exceed 4 (102 mm). Head Frame minimum 1 3/4 (44 mm). Face frame 6 3/4 (171 mm) total operator clearance. Top Rail minimum 2 3/4 (70 mm). Special Templates Customized installation templates or products may be available to solve unusual applications. Contact LCN for assistance. Opening & Closing Time are variable by adjustments to the electronic control box. Maximum hold open time adjustable up to approximately 32 seconds. System Diagram see AUTOMATIC OPERATORS section pages 52-54 for typical system wiring and page 55 for electrical data. Please consult your local SSC representative or LCN for assistance with specific installations and material requirements. 110

LCN 9550 SERIES 2 3/4 " 70 MM BUTT HINGES 48" DOOR OPENING (MAX.) PULL ARM ASS'Y OPERATOR OPERATOR 17" From edge of door 17 3/8 " 11 1/2 " PULL CHANNEL 292 MM PUSH ARM 48" DOOR OPENING (MAX.) ASS'Y 1 3/4 " 44 MM BUTT HINGES 2 3/4 " 70 MM 5 3/4 " 146 MM 1" 25 MM 4 1/2 " 114 MM OPERATOR PUSH ARM ASS'Y SECONDARY LINK DOOR FRAME 2 3/18" FROM BOTTOM OF DOOR STOP 6 3/4 " 171 MM 5 3/4" 146 MM 4 1/2 " 114 MM OPERATOR 1" 25 MM PULL ARM ASS'Y PULL CHANNEL DOOR DIRECTION FRAME DOOR DIRECTION 1 15/16" FROM TOP OF DOOR DOOR TOP JAMB SIMULTANEOUS PAIR (RH DOUBLE EGRESS) MOUNTING Consult factory for all balance door installations. MOUNTING DETAILS INTERIOR HOLLOW METAL FRAME Suggested Installation Butt Hinges should not exceed 5 (127 mm) in width. Reveal for push installations should not exceed 10 (254 mm) for REGULAR ARM and 20 (508 mm) for LONG ARM. Reveal for pull installations should not exceed 4 (102 mm). MAXIMUM OPENING Template allows 90 degree power opening and 90 degree manual opening. Reveal for double egress installations should not exceed 4 (102 mm). Head Frame minimum 1 3/4 (44 mm). Face frame 6 3/4 (171 mm) total operator clearance. Top Rail minimum 2 3/4 (70 mm). Opening & Closing Time are variable by adjustments to the electronic control box. Maximum hold open time adjustable up to approximately 32 seconds. System Diagram see AUTOMATIC OPERATORS section pages 52-54 for typical system wiring and page 55 for electrical data. Please consult your local SSC representative or LCN for assistance with specific installations and material requirements. Special Templates Customized installation templates or products may be available to solve unusual applications. Contact LCN for assistance. 111

ACCESSORIES LCN 9550 SERIES MOTOR GEARBOX MOTOR GEARBOX (STANDARD FORCE) SENIOR, 9550-3454 Driving mechanism for operator. Provides 15lbs opening force. Handed. MOUNTING BRACKETS MOUNTING BRACKET 2 3/4, 9550-275 Motor gearbox mounting bracket for 2 3/4" offset pivot or butt hinge installations. Front bracket. REAR MOUNT BRACKET, 9550-3018 Motor gearbox mounting bracket. Rear bracket. ANGLED BRACKET, 9550-334-1 Mounting bracket for surface applications. CONTROL BOXES CONTROL BOX SENIOR, 9550-3462 Electronic controlling device for Senior Swing. COMPANION CABLE, 9550-982 Cable that allows one control box to run two motor gear boxes. Companion cable. For use with Senior Swing. HEADERS HEADER, 9550-3572HL Standard, mounting header. Pair door, two operators. Specify length 60 to 98 maximum. END CAPS HEADER ENDCAPS, 9550-334 End cap with openings for wiring. END DRESS PLATE, 9550-334-2 Metal finish end cap. 3454 275 3018 344-1 3462 982 3572HL 334 334-2 112

LCN 9550 SERIES ARMS STANDARD ARM ASSEMBLY, 9550-3077PLCM Handed arm. REGULAR ARM ASSEMBLY, 9550-3077 Handed arm. REGULAR LONG ARM ASSEMBLY, 9550-3077L Handed arm. 3077PLCM ACCESSORIES STANDARD ARM, 9550-3077T Handed arm. Track roller not included. MAIN ARM, 9550-77 Handed arm attaches to motor gearbox LINKAGE ASSEMBLY 15, 9550-79 Threaded rod attaches to door. Extends from main arm. LINKAGE ASSEMBLY 32, 9550-79LR Threaded long rod attaches to door. Extends from main arm. Used for reveal 10 to 20. TRACKS TRACK 9550-3038 Standard non-handed track. TRACK END CAP 9550-73 Black plastic end caps. ROLLER, 9550-3034 Quiet low friction roller assembly. INSTALLATION ACCESSORIES SPINDLE PLATE 2 3/4, 9550-11A Hides bottom of motor gearbox. Completes header box. Cutout allows for motor gearbox shaft. For 2 3/4" offset pivot or butt hinge installations. FILLER PLATE BLANK, 9550-12 Completes length of header box. (Specify Length) MOUNTING PLATE, 9550-18 Optional mounting plate for standard hollow metal door frames. Specify length 33 to 98 maximum. NOTE: The length of a universal 18 plate will need to be ordered 3 1/2 longer than the supplied header. 3077 3077L 3077T 77 79 79LR 3038 3034 73 11A 12 18 113

LCN 9550 SERIES ORDERING INFORMATION TABLE OF SIZES Indicates recommended range of door width for operator. Note: For All Senior Swing Series Simultaneous Pair Width per leaf 30 minimum to 48 maximum DOOR WIDTH 60" 1524mm 9553 Minimum Door Width 96" 2438mm HOW-TO-ORDER 9550 SERIES OPERATORS 1. SPECIFY HAND RH LH 2. SPECIFY FINISH. Standard Anodized Finish Aluminum or Dark Bronze Operator will be shipped with: -STANDARD MOTOR GEARBOX (SF) (2 ea) -STANDARD CONTROL BOX (SC) -72 METAL COVER (72HL) -REGULAR ARM (2 ea) -2 3/4 PIVOT POINT -MACHINE SCREW PACK OPERATOR OPTIONS HEADER HL (Specify length 60 to 98 ) MOUNTING PLATE Plate, (Specify Length 30 to 98 ) ARM Standard Arm (2 ea) w/standard Track (2 ea) Double Egress Includes Standard Arm w/track (1 ea) & Regular Arm (1 ea) Long Arm (3077L) SPECIAL TEMPLATE ST- 114

LCN 9560 SERIES OPERATOR MOUNTS INDEPENDENT PAIR, SURFACE MOUNT *PULL SIDE PUSH SIDE DOUBLE EGRESS *PULL SIDE mount shown The 9560 SENIOR by LCN is an ADA door operator that is a two-inone swing door operator. SENIOR operators when activated, opens doors automatically for wheelchair access, yet allows for manual operation for regular pedestrian traffic. Push N Go permits non-switch activation Power Boost provides additional latching force Electromechanical unit with microprocessor control Digital keypad for easy setup Meets International Building Code requirements and ANSI A156.19 UL approved for fire doors FEATURES 9560 series operator is shipped with motor gearboxes, control boxes, arms, header, and mounting hardware. Actuators available separately, see page121. Independent pair, surface mounted. Meets ADA requirements (power mode only). Handed product. Pull, Push or Double Egress applications available. 72 header length is standard. Specify other length 60 to 98. Consult factory regarding this option. Adjustable hold open period of 1 to 32 seconds in automatic or manual mode. MOUNTING CONCEALED SIMULTANEOUS PAIR SURFACE MOUNT SINGLE DOOR SURFACE MOUNT SIMULTANEOUS PAIR SURFACE MOUNT INDEPENDENT PAIR CONCEALED SINGLE DOOR HANDED NON-HANDED CONCEALED INDEPENDENT PAIR HANDING METAL STANDARD ANODIZED CUSTOM ANODIZED CUSTOM PAINT FINISH 9560 Series is fully compliant with UL 325 & UL 1998 and meets the provisions of ANSI A156.19. The 9560 Series is UL listed for fire-rated applications. The 9560 Series also meets the provisions of the Americans with Disabilities Act. COVER ARM FUNCTION STANDARD (SINGLE) REGULAR (DOUBLE) DOUBLE EGRESS (PUSH/PULL) OFFSET PIVOT ARM CENTER PIVOT ARM 115

LCN 9560 SERIES MOUNTING DETAILS TOP JAMB INDEPENDENT PAIR (OFFSET PIVOT/BUTT HINGE, CENTER PIVOT, PUSH) MOUNTING OUTGOING PUSH ARM ASS'Y 17" From edge of door OPERATOR REVEAL OUTGOING 4 1/2 " 114 MM 6 3/4 " 5 3/4 " OPERATOR 171 MM 146 MM OFFSET 1" PIVOT 25 MM or BUTT HINGES SECONDARY LINK 2 3/4 " 70 MM 1 7/16 " From top of door DIRECTION DOOR 8'-0" DOOR OPENING (MAX.) DOOR FRAME EXTERIOR TOP JAMB INDEPENDENT PAIR (OFFSET PIVOT/BUTT HINGE, CENTER PIVOT, PULL) MOUNTING 4 1/2 " 114 MM 8'-0" DOOR OPENING (MAX.) 17 3/8 " 11 1/2 " 5 3/4 " 441 MM 291 MM 6 3/4 " 146 MM 2 3/4 " 171 MM 70 MM OPERATOR PULL CHANNEL OPERATOR OFFSET PIVOT 1" PULL ARM or ASS'Y BUTT 1 15/16 " 25 MM HINGES 49 MM PULL ARM ASS'Y PULL CHANNEL INCOMING INTERIOR INCOMING DIRECTION 1 3/4 " 44 MM INTERIOR DOOR MAXIMUM OPENING Template allows 90 degree power opening and 90 degree manual opening. Butt Hinges should not exceed 5 (127 mm) in width. Reveal for push installations should not exceed 10 (254 mm) for REGULAR ARM and 20 (508 mm) for LONG ARM. Reveal for pull installations should not exceed 4 (102 mm). Reveal for double egress installations should not exceed 4 (102 mm). Head Frame minimum 1 3/4 (44 mm). Face frame 6 3/4 (171 mm) total operator clearance. Top Rail minimum 2 3/4 (70 mm). Special Templates Customized installation templates or products may be available to solve unusual applications. Contact LCN for assistance. Opening & Closing Time are variable by adjustments to the electronic control box. Maximum hold open time adjustable up to approximately 32 seconds. System Diagram see AUTOMATIC OPERATORS section pages 52-54 for typical system wiring and page 55 for electrical data. Please consult your local SSC representative or LCN for assistance with specific installations and material requirements. 116

LCN 9560 SERIES 2 3/4 " 70 MM BUTT HINGES 48" DOOR OPENING (MAX.) PULL ARM ASS'Y OPERATOR OPERATOR 17" From edge of door 17 3/8 " 11 1/2 " PULL CHANNEL 292 MM PUSH ARM 48" DOOR OPENING (MAX.) ASS'Y 1 3/4 " 44 MM BUTT HINGES 2 3/4 " 70 MM 5 3/4 " 146 MM 1" 25 MM 4 1/2 " 114 MM OPERATOR PUSH ARM ASS'Y SECONDARY LINK DOOR FRAME 2 3/18" FROM BOTTOM OF DOOR STOP 6 3/4 " 171 MM 5 3/4" 146 MM 4 1/2 " 114 MM OPERATOR 1" 25 MM PULL ARM ASS'Y PULL CHANNEL DOOR DIRECTION FRAME 1 15/16" FROM TOP OF DOOR TOP JAMB INDEPENDENT PAIR (RH DOUBLE EGRESS) MOUNTING Consult factory for all balance door installation. MOUNTING DETAILS DOOR DIRECTION DOOR INTERIOR HOLLOW METAL FRAME Suggested Installation Butt Hinges should not exceed 5 (127 mm) in width. Reveal for push installations should not exceed 10 (254 mm) for REGULAR ARM and 20 (508 mm) for LONG ARM. Reveal for pull installations should not exceed 4 (102 mm). Reveal for double egress installations should not exceed 4 (102 mm). Head Frame minimum 1 3/4 (44 mm). Face frame 6 3/4 (171 mm) total operator clearance. Top Rail minimum 2 3/4 (70 mm). Opening & Closing Time are variable by adjustments to the electronic control box. Maximum hold open time adjustable up to approximately 32 seconds. System Diagram see AUTOMATIC OPERATORS section pages 52-54 for typical system wiring and page 55 for electrical data. Please consult your local SSC representative or LCN for assistance with specific installations and material requirements. MAXIMUM OPENING Template allows 90 degree power opening and 90 degree manual opening. Special Templates Customized installation templates or products may be available to solve unusual applications. Contact LCN for assistance. 117

ACCESSORIES LCN 9560 SERIES MOTOR GEARBOX MOTOR GEARBOX (STANDARD FORCE) SENIOR, 9560-3454 Driving mechanism for operator. Provides 15lbs opening force. Handed. MOUNTING BRACKETS MOUNTING BRACKET 2 3/4, 9560-275 Motor gearbox mounting bracket for 2 3/4" offset pivot or butt hinge installations. Front bracket. REAR MOUNT BRACKET, 9560-3018 Motor gearbox mounting bracket. Rear bracket. ANGLED BRACKET, 9560-334-1 Mounting bracket for surface applications. CONTROL BOXES CONTROL BOX SENIOR, 9560-3462 Electronic controlling device for Senior Swing HEADERS HEADER, 9560-3572HL Standard, mounting header. Pair door, two operators. Specify length 60 to 98 maximum. END CAPS HEADER END CAPS, 9560-334 End cap with openings for wiring. END DRESS PLATE, 9560-334-2 Metal finish end cap. 3454 275 3018 344-1 3462 3572HL 334 334-2 118

LCN 9560 SERIES ARMS STANDARD ARM ASSEMBLY, 9560-3077PLCM Handed arm. REGULAR ARM ASSEMBLY, 9560-3077 Handed arm. 3077PLCM ACCESSORIES REGULAR LONG ARM ASSEMBLY, 9560-3077L Handed arm. STANDARD ARM, 9560-3077T Handed arm. Track roller not included. MAIN ARM, 9560-77 Handed arm attaches to motor gearbox LINKAGE ASSEMBLY 15, 9560-79 Threaded rod attaches to door. Extends from main arm. LINKAGE ASSEMBLY 32, 9560-79LR Threaded long rod attaches to door. Extends from main arm. Used for reveal 10 to 20. TRACKS TRACK 9560-3038 Standard non-handed track. TRACK END CAP 9560-73 Black plastic end caps. ROLLER, 9560-3034 Quiet low friction roller assembly. INSTALLATION ACCESSORIES SPINDLE PLATE 2 3/4, 9560-11A Hides bottom of motor gearbox. Completes header box. Cutout allows for motor gearbox shaft. For 2 3/4" offset pivot or butt hinge installations. FILLER PLATE BLANK, 9560-12 Completes length of header box. (Specify Length) MOUNTING PLATE, 9560-18 Optional mounting plate for standard hollow metal door frames. Specify length 33 to 98 maximum. NOTE: The length of a universal 18 plate will need to be ordered 3 1/2 longer than the supplied header. 3077 3077L 3077T 77 79 79LR 3038 3034 73 11A 12 18 119

LCN 9560 SERIES ORDERING INFORMATION TABLE OF SIZES Indicates recommended range of door width for operator. Note: For all Senior Swing Series Independent Pair Width per leaf 30 minimum to 48 maximum DOOR WIDTH 60" 914mm 9563 Minimum Door Width 96" 1219mm HOW-TO-ORDER 9560 SERIES OPERATORS 1. SPECIFY HAND RH LH 2. SPECIFY FINISH. Standard Anodized Finish Aluminum or Dark Bronze Operator will be shipped with: -STANDARD MOTOR GEARBOX (SF) (2 ea) -STANDARD CONTROL BOX (SC) (2 ea) -72 METAL COVER (72HL) -REGULAR ARM (2 ea) -2 3/4 PIVOT POINT -MACHINE SCREW PACK Unless options listed below are selected. OPERATOR OPTIONS HEADER HL (Specify length 60 to 98 ) MOUNTING PLATE Plate, (Specify Length 30 to 98 ) ARM Standard Arm (2 ea) w/standard Track (2 ea) Double Egress Includes Standard Arm w/track (1 ea) & Regular Arm (1 ea) Long Arm (3077L) SPECIAL TEMPLATE ST- 120

*740100* 740100 2800 Overhead Consealed Series 9500 Surface Applied Series Senior Swing Control Box Installation Instructions important These instructions are presented in step-by-step sequence. It is very important that installation begins with 1. Pre-Installation Site and Product Check (page 3) and continues as directed after each section. warning Always disconnect main power to the operator prior to replacing. Control box contains no serviceable parts inside. Table of Contents General Information... 1 Electrical Specifications... 2 1 Pre-Installation Site and Product Check... 2 2 Installation... 3 3 Wiring... 3 4 Keypad Settings... 7 5 System Test...11 6 Troubleshooting... 12 7 Release for Service... 13 General Information The Senior Swing Control Box is for use with the Senior Swing Power Operator System. The system can operate a single door (2810, 9530, and 9540 Series), a simultaneous pair of doors (2850 and 9550 Series), or an independent pair of doors (2860 and 9560 Series). ANSI/BHMA A156.19 Compliance The Senior S wing Power Operator System is a low energy product and must conform to the latest version of ANSI/BHMA A156.19 (American National Standard for Power Assist and Low Energy Power Operated Doors). Installation Instructions All installation instructions are valuable references and should be given to the building owner or maintenance supervisor after installation is complete. The Senior Swing Control Box installation instructions and the manufacturer s instruction manual accompanying any sensor must be referenced to ensure proper installation, setup, and operation.

No Serviceable Parts Inside Electrical Specifications AC input voltage... 120 VAC AC fuse... 120 VAC, 2.5 A time-delay fuse Motor protection... Solid state failure detection and shutdown Activate inputs... dry NO contacts (close contacts to open door) Safety inputs... dry NO contacts (closed contacts indicate an obstruction) Breakaway input... dry NC contacts (open contacts indicate breakaway) 3-position switch input... dry 3-position switch Power Boost disable input... dry NO contacts (close contacts to disable Power Boost) Lock output... Form C dry relay contacts rated 8 A, 30 VDC maximum Accessory power output... 24 VAC, 1.5 A (protected by resettable thermal fuse) Logic power output... 5 V, 50 ma (protected by resettable thermal fuse) 1 Pre-Installation Site and Product Check important Factory Authorized Door Leaf Size and Weight Type Width per Leaf Maximum Weight per Leaf Single Door 36 to 48 200 lb. Simultaneous Pair 30 to 48 200 lb. 1a 1b 1c 1d All required installation steps listed before 8. Control Box Installation in the Senior Swing installation instructions should be completed before installing the Senior Swing control box. Check that the control box model (indicated on control box label; Figure 1-1) is correct for the application. Check that the available AC voltage matches the control box voltage requirement (120 VAC). Check that all accessories required for the application are on hand. Label indicates model COMPANION MOTOR CAUTION: 120 VAC 2.5 A TIME-DELAY FUSE WARNING: FOR CONTINUED PROTECTION AGAINST FIRE, REPLACE ONLY WITH SAME TYPE AND RATING OF FUSE. COMPANION S L O W CLOSE SPEED F A S T S L O W MASTER CLOSE SPEED F A S T UP DOWN SETTING VALUE : OPENING SPEED : BACKCHECK SPEED : BACKCHECK POS. : HOLD-OPEN DELAY UP : LATCH POSITION : AUTO-REV. CLOSING : ELECTRIC LOCK : POWER BOOST DOWN : PUSH N GO : ALTERNATE ACTION : SAFETY SLOW/STOP : SPECIAL : STATUS ANNOUNCEMENT DEFAULT POWER ON SENIOR 710164 WARNING: ALL SPEED SETTINGS (OPENING, CLOSING, AND LATCHING) AND HOLD-OPEN TIME- DELAY MUST BE FIELD ADJUSTED TO MEET LATEST APPLICABLE ANSI/ BHMA STANDARDS. DMSS #2 APPROACH P5 DMSS #2 SAFETY P4 ELECTRIC LOCK P10 RETROFIT P8 DMSS #1 APPROACH P3 DMSS #1 SAFETY P2 BODYGUARD ACTIVATE ACTIVATE P1 P6 P7 Figure 1-1

2 Installation To install the Senior Swing Control Box, follow the Senior Swing installation instructions beginning with 8. Control Box Installation on page 12 of those instructions. caution Improper installation or set up may result in personal injury or property damage. Follow instructions carefully. For answers to questions, call 1-877-671-7011 3 Wiring Review the separate wiring diagrams in the accessory instructions so that all wiring can be completed. See Figure 3-1 for system configuration terminology. See Figure 3-2, Figure 3-3, and Figure 3-4 for names and locations of control box connectors. See Figure 3-5 for control box plug and jack descriptions, wiring, and mating cables. See Figure 3-6 for electric strike locking device sample wiring. See Figure 3-7 for EL (electric latch retraction) locking device sample wiring. caution When joining or separating a plug and receptacle, do not push or pull on wires. This may cause a wire to be pulled loose from a terminal, which may result in a malfunction. Connect single door operator to Master Motor Power cable from control box Connect operator for second door to control box Companion Motor Power receptacle (P5 on control box power board) Safety side Approach side Safety side Approach side Connect master operator to control box Master Motor Power cable

P4 P 1 0 AC fuse, 120 VAC 2.5 A time-delay POWER BOARD Companion motor power (P5) AC power LOGIC BOARD Master motor power Figure 3-2. Control box power board connectors. POWER BOARD Breakaway See Figure 3-4 for closeup of control box logic board connectors 3-position switch LOGIC BOARD Figure 3-3. Control box logic board connectors. DMSS (companion; approach side) DMSS (companion; safety side) P5 Locking Interface and Power Boost disable input LOGIC BOARD P8 Retrofit Accessories P3 P2 P1 P6 P7 DMSS (master; approach side) DMSS (master; safety side) Bodyguard (safety side) Activate Activate Figure 3-4. Closeup of control box logic board connectors.

Bodyguard (master; safety side): Prevents door from opening; holds open door in open position (uses door state data from control box to ignore door movement while opening/closing) P1 on-board connector If used Cable 761468 Bodyguard JST-type connector Bodyguard cable to Bodyguard sensor LOGIC BOARD DMSS (master; safety side): Prevents door from opening, and slows an opening door DMSS (master; approach side): Initiates a door opening cycle if activated while door is closing DMSS (companion; safety side): Prevents door from opening, and slows an opening door DMSS (companion; approach side): Initiates a door opening cycle if activated while door is closing Activate: Initiates a door opening cycle Activate: Initiates a door opening cycle (operates identically to P6 and is provided as a convenience if 2 activations are used) P2 on-board connector P3 on-board connector P4 on-board connector P5 on-board connector P6 on-board connector P7 on-board connector If used If used If used If used If used If used Safety Approach Safety Approach Cable 761464 Cable 761464 Safety Safet y DMSS harness 761467 A pproach Approach DMSS harness 761467 Black, 24 VAC White, 24 VAC Yellow, Activate Gray, Ground Black, 24 VAC White, 24 VAC Yellow, Activate Gray, Ground Black, 24 VAC Red, 24 VAC White, Slowdown Green, Ground Black, 24 VAC Red, 24 VAC White, Activate Green, Ground Black, 24 VAC Red, 24 VAC White, Slowdown Green, Ground Black, 24 VAC Red, 24 VAC White, Activate Green, Ground To DMSS (master; safety side) To DMSS (master; approach side) To DMSS (companion; safety side) To DMSS (companion; approach side) Used only for powered activation device Activate cable To normally open Activate contacts Used only for powered activation device Activate cable To normally open Activate contacts Retrofit Accessories: Accesses older model Activate, Slow/Stop, and Carpet Safety inputs P8 on-board connector Retrofit only Cable 761469 Blue, Carpet Safety Gray, Ground Yellow, Activate Violet, Slowdown To existing cable 710057 (old part No. 81276) Breakaway: Disables operator inputs when Breakaway switch is active 3-Position Switch: OFF, AUTO, HOLD permanent connections permanent connections Orange Black Red Green Black To normally closed Breakaway switch or jumper 81269 To 3-position switch (if used) Locking Interface: Power output and relay contacts for locking devices; Power Boost disable input P10 on-board connector If used Cable 761465 Blue, Power Boost disable Black, Ground Violet, Relay NO Gray, Relay COM Brown, Relay NC Green, 5 V White, 24 VAC White, 24 VAC Ground To normally open Power Boost disable contacts To locking device (see page 7 for sample wiring) POWER BOARD Companion Motor Power: Companion motor power (use only for second door of simultaneous pair of doors) Master Motor Power: Master motor power (use for single door) AC Input: 120 VAC P5 on-board connector permanent connections permanent connections If used Cable 761466 Cable 761463 Black, Hot AC White, Neutral AC Green, Earth Ground To motor cable of companion operator (use only for second door of simultaneous pair of doors) To motor cable of master operator (always use for single door) To 120 VAC Figure 3-5

LL NOTE: Always wire the locking device to the NO (normally open) contact of the control box locking interface and use the keypad to set the EL (electric lock) setting to either SA (fail safe) or SE (fail secure). Control box lock supply rating: 24 VAC, 1.5 A Cut connector off rectifier, then connect using wire nuts White White White White Rectifier (for DC strikes) Black Red Senior Swing control box Gray (COM) Violet (NO) Cable 761465 to Senior Swing control box locking interface receptacle (P10) Fail safe electric strike The keypad EL (electric lock) setting is SA (fail safe). When the operator is on, the strike is locked when the door is closed and unlocked when the door is opening. When the 3-position switch is set to OFF, the strike is unlocked. Figure 3-6. Sample Wiring for a Fail Safe Electric Strike Locking Device Cable 761465 to Senior Swing control box locking interface receptacle (P10) Von Duprin PS914 x 900-2RS SC I1 01 I2 02 GND Gray (COM) Violet (NO) Senior Swing control box When using an EL device such as EL33A, EL99, etc: Use 12 AWG stranded wire for outputs 01 and 02 between PS914 and EL device (200 run maximum). EL device The keypad EL (electric lock) setting is SE (fail secure). The control box locking relay signals the PS914 x 900-2RS. When the operator is on, the EL device is locked when the door is closed and unlocked when the door is opening. When the 3-position switch is set to OFF, the EL device is locked. Figure 3-7. Sample Wiring for a Fail Secure EL (Electric Latch Retraction) Locking Device

No Serviceable Parts Inside 4 Keypad Settings Settings (except for close speed) for the Senior Swing Power Operator System are changed using keypad pushbuttons and an alphanumeric display on the control box (Figure 4-1 and Figure 4-2). Close speed is changed using dials on the control box (Figure 4-1). See page 9 and page 10 for directions for changing the values of settings. caution Adjust the operator for the slowest operation practical in accordance with the latest revisions of Americans with Disabilities Act, ANSI/BHMA A156.19 (American National Standard for Power Assist and Low Energy Power Operated Doors), and local codes. COMPANION MOTOR CAUTION: 120 VAC 2.5 A TIME-DELAY FUSE WARNING: FOR CONTINUED PROTECTION AGAINST FIRE, REPLACE ONLY WITH SAME TYPE AND RATING OF FUSE. COMPANION S L O W CLOSE SPEED F A S T S L O W MASTER CLOSE SPEED F A S T UP DOWN SETTING VALUE : OPENING SPEED : BACKCHECK SPEED : BACKCHECK POS. : HOLD-OPEN DELAY UP : LATCH POSITION : AUTO-REV. CLOSING : ELECTRIC LOCK : POWER BOOST DOWN : PUSH N GO : ALTERNATE ACTION : SAFETY SLOW/STOP : SPECIAL : STATUS ANNOUNCEMENT DEFAULT POWER ON SENIOR 710164 WARNING: ALL SPEED SETTINGS (OPENING, CLOSING, AND LATCHING) AND HOLD-OPEN TIME- DELAY MUST BE FIELD ADJUSTED TO MEET LATEST APPLICABLE ANSI/ BHMA STANDARDS. DMSS #2 APPROACH P5 DMSS #2 SAFETY P4 ELECTRIC LOCK P10 RETROFIT P8 DMSS #1 APPROACH P3 DMSS #1 SAFETY P2 BODYGUARD ACTIVATE ACTIVATE P1 P6 P7 Close speed dials Keypad Figure 4-1. Control Box Panel with Keypad Setting display Value display SETTING VALUE DEFAULT Reset to default values pushbutton Setting selection pushbuttons UP DOWN POWER : OPENING SPEED ON : BACKCHECK SPEED : BACKCHECK POS. : HOLD-OPEN DELAY UP : LATCH POSITION : AUTO-REV. CLOSING : ELECTRIC LOCK : POWER BOOST DOWN : PUSH N GO : ALTERNATE ACTION : SAFETY SLOW/STOP : SPECIAL : STATUS ANNOUNCEMENT Value selection pushbuttons Figure 4-2. Closeup of Control Box Keypad

warning KEEP HANDS, CLOTHING, WIRES, TOOLS, LADDERS, ETC. AWAY FROM THE DOOR WHEN THE OPERATOR IS INITIALLY TURNED ON. See Figure 4-3 for definitions of the positions of the door throughout the opening and closing cycle. See Table 4-1 for explanations of the keypad settings. To change setting values: 1. Set the 3-position switch, if used, to OFF. 2. Apply AC power. The POWER light will illuminate and the display will remain blank. 3. Press any two pushbuttons at the same time for 1 second to turn on the keypad. The display will illuminate. 4. Press the UP or DOWN setting selection pushbutton to select the desired setting. The setting is shown in the SETTING display, and the current value for that setting is shown in the VALUE display. 5. Press the UP or DOWN value selection pushbutton to select the desired value for the displayed setting. The value for the setting is indicated in the VALUE display. 6. The keypad will automatically turn off after 5 minutes of inactivity. To reset all values to default (default values are listed in Table 4-1 under Selectable Values ): 1. Set the 3-position switch, if used, to OFF. 2. Apply AC power. The POWER light will illuminate, and the display will remain blank. 3. Press any two pushbuttons at the same time for 1 second to turn on the keypad. The display will illuminate. 4. Press the DEFAULT pushbutton for 4 seconds. 5. The values are set to default, and the display will indicate the opening speed setting and value. 6. The keypad will automatically turn off after 5 minutes of inactivity. Back check speed Back check position Opening speed Closing speed Latch position Deceleration to fully closed position Figure 4-3. Door Position Definitions

Safety side Door Mounted Safety Sensor (DMSS) disable feature Purpose: Deactivate the Door Mounted Safety Sensor (DMSS) on safety side of door to eliminate nuisance detection of a wall or guard rail. 1. Install control box, all door hardware and safety devices per their instructions. 2. Setup DMSS sensors in accordance with ANSI standard 156.10. 3. Use keypad to set SAFETY SLOW/STOP (SS) value to STOP (SP). 4. Use keypad to set SLOWDOWN DISABLE (SD) value to 85. 5. Activate door opening cycle. If door does not open fully, use keypad to reduce SD value from 85 in 5 degree increments. 6. Repeat Step 5 until door opens fully. 7. Perform a complete system test as described in the section 5. Wall Safety side DMSS Sensor Door DMSS Sensor Active Sensor (85 degrees or less) Frame

Table 4-1. Control Box Settings and Selectable Values Setting Opening Speed Back Check Speed Back Check Position Hold Open Delay Latch Position Auto Reverse Closing Electric Lock Setting Display Selectable Values 01 = slow 02 = medium 03 = fast (default = 01) 01 = 1 door 02 = 2 doors (default = 01) Values as Displayed 45-80 degrees (default = 70) 01-32 seconds (default = 05) 00-23 degrees (default = 13) off, on (default = off) off SA = fail safe SE = fail secure (default = off) Power Boost off 5 seconds continuous (default = off) Push N Go off, on, fd (default = off) Alternate Activate Safety Slow/Stop off, on (default = off) slow, stop (default = slow) Special Status Announcement off 30-85 (default = off) Reserved Reserved Description Controls opening speed of any normal weight and size door Controls speed of door near full open position to prevent door slamming open Approximate angle at which door begins to decelerate near the full open position Amount of time (in seconds) door remains fully open following an activate signal Approximate angle at which door begins to decelerate near the full closed position When on, door will re-open upon hitting an obstruction To turn on, set to SA (fail safe) or SE (fail secure) to match locking device connected to control box locking interface receptacle (P10); when on, causes a 1 second delay between activate signal and door opening to allow time for most electric locks to disengage before operator opens door When on, increases closing force of door from 9 lbs to 18 lbs to close door against high winds or stack pressure; turns on for 5 seconds or continuously after door reaches latch position during closing cycle; disabled by Power Boost disable input When set to On or Fd, pushing door open 5 degrees causes operator to open door remainder of way and hold open. Hold open time is same as hd setting when set to On. Hold open time is 1 second when set to Fd. When on, door stays open until a second activate signal is received. Determines response to a DMSS on the safety side of the door; if SL (slow), door goes to back check speed; if SP (stop), door stops for 5 seconds, then continues opening at back check speed Deactivate the Door Mounted Safety Sensor (DMSS) on safety side of door to eliminate nuisance detection of a wall or guard rail. Reserved