IRIS enhancing the value of the building...

Similar documents
Your Elevator Partner

MACHINE ROOM-LESS ELEVATOR

ELEVATOR S GENERAL FUNCTIONS GUIDE

Vertical Dreams XJ SIEMENS. Vertispace Cargo Elevator. English. Deutsch. 中文 Français

Passenger Elevator with Machine Room

Features: 1 Compact, Energy Efficient Machine. 2 Controller. 3 Governor. 4 Door Control System. 5 Revolutionary Coated Steel Belts

Hitachi Elevator VFI-II

Creating An Accessible World ELVORON CPL.

GeN2 Comfort lift. A machine roomless system with unsurpassed levels of comfort, reliability, safety and environmental protection.

ELVORON HOME ELEVATOR

Elvoron Home Elevator

Vertical Dreams XJ SIEMENS. Optima MRL Elevators. English. Deutsch. 中文 Français

Machine-Room-Less Elevator

U.S.A / CANADA. USA CNS Automation, Inc E. Firestone Blvd. La Mirada, CA Tel : Fax :

Midrise Elevator. MRL MR Gearless MR Geared. Elevator Technology (Korea) Export Division

Home Elevator. Planning Guide

GFC-L3 ADVANCED TECHNOLOGIES. The Best Helper to Enhance the Efficiency of your Modern Factory GFC-L3. Comfort. Efficiency. Safety.

ELVORON HR DESIGN AND PLANNING GUIDE

TRIVIUM ENTER ANOTHER DIMENSION

Introduction Ecology Safety and Comfort Car Designs 5 7 Hall Design Basic Specifications 9-10 Electrical Installation Entrance Layout Drawings

NIPPON GOODS & CAR LIFT

SHAFT DIMENSIONS AND OPTIONS m/s; kg. KONE MonoSpace 700

Schindler 7000 Planning parameters of high-rise elevators.

Your Elevator Partner

Elvoron CPL. Planning Guide

I N D I A N S T A T I S T I C A L I N S T I T U T E

Schindler Schindler Passenger Elevators

in service THE ELEVATOR THAT YOU PLUG IN LIKE A DOMESTIC APPLIANCE

Standard VVMC-1000 or VFMC-1000 controls, dispatched by an M3 Group System, allow group configurations with 64 landings and as many as 12 cars.

RIDE QUALITY. All you need is a hoistway

RIDE QUALITY All you need is a hoistway

CHN-EN Otis Elevator Company

PASSENGER ELEVATORS (COMPACT MACHINE ROOM SYSTEM) Series-IP/AP Version 2 Series-IP

We care about your goods

Premier. Otis Elevator Company is the world's leading manufacturer and maintainer of elevators, escalators and moving walkways.

Machine-room-less electrical gearless solutions (MRLG)

Elevator Technology. synergy 100. Fact sheet.

ELEVATOR & ESCALATOR SYSTEMS. SHENYANG AMTE INDUSTRIES LLC Add.: No. 135, Changjiang Street, Huanggu District, Shenyang, China.

PASSENGER ELEVATORS (HIGH-SPEED STANDARD-TYPE)

DESCRIPTION OF OPERATION EcoSpace elevator with KCM831 control

TABLE OF CONTENTS. Contractor Notes 2. Specifications for Symmetry 3-4 Residential Elevator. Typical Hoistway Configurations 5-7

RIDE QUALITY. All you need is a hoistway

Silens-Pro Top. Machine. Excellence. Ultramodern. Uniquely

OPTIONS AND SHAFT DIMENSIONS m/s; kg. KONE MonoSpace 500

Built for every day, designed for any style.

PASSENGER ELEVATORS MACHINE-ROOM-LESS SYSTEM. Designed to European standards

Elevator Technology. synergy. element package. Fact sheet.

Routine made Exceptional

Home Elevator. Specifically engineered for residential applications

State-of-the-Art Factories For the Environment. For Product Quality. Certification

U n i n t e r r u p t i b l e P o w e r S y s t e m

Elevator Technology. uniq. Fact Sheet BO 61 F 00-40

PASSENGER ELEVATOR MODERNIZATION A CHOICE OF MODERNIZING YOUR ELEVATORS

Infinity & Infinity HD

synergy S1 Flexibility meets efficiency.

1.3~2.0 Ton Series Electric/3-Wheel(48Volt)

Green Elevator: minimal energy consumption required during ascent and no energy necessary for descent

home lift Italian Excellence and Design

PASSENGER ELEVATOR (COMPACT MACHINE ROOM SYSTEM) Series-AP Version2

Built for every day, designed for any style.

HOSPITAL BED ELEVATORS

A COST-EFFECTIVE ELEVATOR FOR LOW-RISE RESIDENTIAL BUILDINGS. KONE EcoSpace

Comfort. Smooth Silent Precise. The best sensation is not to notice anything. A dream lifestyle

Installation plan and power facility plan for Taiwan

Smooth Silent Precise. The best sensation is not to notice anything. A dream lifestyle

BUREAU OF INDIAN STANDARDS DRAFT FOR COMMENTS ONLY. (Not to be reproduced without the permission of BIS or used as an AMENDMENT)

Carlift Series PHP 220F

DEEP SEA ELECTRONICS PLC

Distributed by. Elevador de inversor distribuido

ASTRON. Automobile Elevator Moving Solutions with safety and Reliability. MRL Machine Room Less ELEVIO

Ecology Using Energy Wisely 7 8. Standard Design 15. Features Basic Specifications (m/sec) (m/sec) 3.

( 0.53~1.6KVA ) 220V 0.2~2.2KW ( 0.53~4.0KVA ) 440V 0.75~2.2KW

Built for every day, designed for any style.

Your Safety is Our Top Priority

Design of Parking Facilities. Design of Parking Facilities. Location of Parking Facilities

A LUXURY STANDARD CREATING A LIFETIME HOME

GeN2 TM Mod. Range of application GeN2 Mod 2:1 roping. 450 kg kg kg 8

Schindler 3100 Practical and reliable. Our passenger elevator with all essentials on board. Schindler Passenger Elevators

TOWER MAXI T SINGLE CONVERSION ON LINE UPS SYSTEMS

PASSENGER ELEVATORS MACHINE-ROOM-LESS SYSTEM

Routine made Exceptional

MODERNIZATION OF PASSENGER ELEVATOR CONTROL SYSTEM. for a greener tomorrow

Routine made Exceptional

GOING UP IN SPACE. KONE TranSys Passenger

PASSENGER ELEVATORS. Designed to European standards

Major Code changes MESA Continuing Education

Schindler 3300 A remarkable style that suits the building. The machine room-less passenger elevator that unifies form and function.

HOSPITAL BED ELEVATORS

We create moving experience AAVA ELEVATORS PVT. LTD.

A COST EFFECTIVE ELEVATOR FOR LOW-RISE RESIDENTIAL BUILDINGS. KONE EcoSpace

Your Elevator Partner

Introduction. Lift and Escalator Safety and their Protection. Lifts and Escalators Mechanism in HK Lift System Escalator System

REFERENCE STANDARD RS-18 ELEVATORS AND CONVEYORS REFERENCE STANDARD RS 18-1

THE COMPLETE ELEVATOR MODERNIZATION SOLUTION. KONE ReVolution

STRATUS ELEVATOR Installation and Operation Manual

A COST EFFECTIVE ELEVATOR FOR LOW-RISE RESIDENTIAL BUILDINGS. KONE EcoSpace

Tricon by MCE Data Form Motion Control Engineering Phone (916) Fax: (916)

Introduction. Ecology 7 8. Efficiency Safety and Comfort Standard Design 15. Features Basic Specifications (m/sec)

NOTES ON ELEVATOR SYSTEMS

Schindler The Escalator. Enjoy moving. Schindler Escalators

Transcription:

IRIS enhancing the value of the building... IRIS maximizing energy savings IRIS enabling environment protections IRIS pursuing space savings IRIS providing ride comfort IRIS ensuring safety & reliability

Your partner for Elevator IRIS is the rainbow goddess in Greek mythology IRIS represents High Quality, Excellent Aesthetic Design, Short Delivery and Best Service SIGMA Elevator 2

Revolutionary Development Concept Groundbreaking low & mid speed elevators substitute the Geared Machine with highly efficient Gearless Machine that adopts Permanent Magnet Synchronous Motor(PMSM) and exclusive PMSM controller IRIS : Features Coverage Speed : 1.0 ~ 2.5m/s Duty : Up to 1,00kg Stops : Up to 32stops (1.0 ~ 1.75m/s) Up to 40stops (2.0 ~ 2.5m/s) Main Features Green Elevator - Energy Savings - Environment Protections - Space Savings Ride Comfort Safety and Reliability 3

Green Elevator : IRIS Sigma's goal of green product includes compliance with stringent environmental standards. Accordingly, our approach to an environmentally acceptable product design requires careful consideration of the entire product life cycle from design to production, and has better solutions for people. Energy Savings IRIS pursues cost savings of building power supply by reducing the capacity of electical facility required for the operation of the elevator. High Motor Efficiency By using permanent magnet(pm) gearless motor, IRIS improves motor efficiency. Lower Power Consunptiom Compact motor design enables IRIS to lower initial electricity load and power consumption. It also allows IRIS to reduce heat from the motor. 0.95 0.93 0.91 0.9 0.7 0.5 0.3 0.1 0.79 0.77 0.75 PM Gearless Machine PM Motor Efficiency Advantage of PM Gear Machine 0 10 30 40 0 70 0 SIGMA Elevator 4

IRIS : Benefit Evironment Protections No need for lubricant oil By using PM Gearless, IRIS is free from lubricate oil for the gear box. This enables us not only to reduce maintenance cost but also to keep machineroom cleaned. EMC filters IRIS uses EMC filters which meet CISPR public 22 class. It minimizes interference from electrical and electronic equipment like home appliances in the building. Space Savings Compact machine Customers may benefit 1/3 space from a smaller size. Flexible space design and utilization IRIS enables architects to design building structure flexibly and use building space efficiently. 5

Ride Comfort Gearless system The absense of gearbox allows to eliminate noise from gear friction. Its coaxial transmission also reduces vibration and noise effectively. Controller design for lower noise Low noise is possible by applying high frequency of khz for synchronous motor controller. SPEED Constant Speed Adjustable decceleration Final stop Smooth Operation IRIS adopts VVVF(Variable Voltage Variable Frequency)control with 5th generation IPM and IGBT, and is designed for low Adjustable acceleration TIME vibration. SIGMA Elevator

: IRIS SIGMA`s cutting-edge gearless technology is favored to suit contemporary buildings. IRIS enables the value of the building to increase with its new concepts. IRIS : Benefit Safety and Reliability Flexible CPU Totally digitally design applying 32bit DSP(Digital Signal Processor) or PM motor speed control. Easy Maintenance Operation history log, mal-function analyzing system applied. Guaranteed Reliability HALT(Highly Accelerated Life Test) on parts to decrease defects and increase life span of parts. Full power reserve of motor A sufficrent power reserve will ensure safer and more reliable operation of the elevator. EMI Test (Electro Magnetic Interference) ESD Test (Electro Static Discharge) Vibration and Dropping Test Burst Test 7

Basic Line Specification Ceiling OPB Wall Door Handrail Floor C-HX2 CBM-10C Steel painted finish (No. DSP-002W) Steel painted finish (No. DSP-002W) HR-01 (Stainless steel) Deco Tile (Local)

Cool Line Specification Ceiling OPB Wall Door Handrail Floor C-32A CBM-10C STS Hairline STS Hairline HR-04 Deco Tile (Local) 9

Modern Line Specification Ceiling C-HX3 OPB CBM-31 CPI CID-10 Wall STS Hairline Etching (No. DSE-00W) Door STS Hairline Etching (No. DSE-00D) Handrail HR-04 Floor Deco Tile (Local) 10

Natural Line Specification Ceiling OPB Wall Door Handrail Floor C-HX2 CBM-10C STS Hairline Etching (No. DSE-019W) STS Hairline Etching (No. DSE-019D) HR-04 Deco Tile (Local)

Entrance Designs Specification 1 JambNarrow Jamb in Painted Steel Sheet (No. DSP-004W) DoorPainted Steel Sheet (No. DSP-004W) SillExtruded Hard Aluminum Hall Indicator & ButtonVID-M432 Specification 2 JambWide Jamb in STS Hairline DoorSTS Hairline SillExtruded Hard Aluminum Hall Indicator & ButtonVID-M432 Specification 3 JambWide Tapered Jamb with Transom Panel STS Hairline finish DoorSTS Hairline Etching (No. DSE-0190D) SillExtruded Hard Aluminum Hall IndicatorHID-A122 ButtonHBM-S43 12

Etching Patterns & Colors Etching Pattern DSE-001D / DSE-001W DSE-002D / DSE-002W DSE-003D / DSE-003W DSE-004D / DSE-004W DSE-00D / DSE-00W DSE-0D / DSE-0W DSE-01D / DSE-01W DSE-019D / DSE-019W DSE-***D : Etching Pattern for Car / Landing door DSE-***W : Etching Pattern for Car wall Painted Steel Sheet Color DSP-001W DSP-002W DSP-003W DSP-0C DSP-017C Actual colors may be different from these prints. 13

Fixtures Ceiling Car Operating Panel C-32A C-SL4 C-HX2 CBM-10C CBM-31 Hall Button C-HX3 HBM-S43 VID-M432 VID-M432T C-MX3 HBM-S42 VID-M422 VID-M422T 14

Fixtures Handicapped COP Hall Lantern CBM-42SH HLV-C0 HLV-30 HLV-C Hall Position Indicator HID-A122 HID-A132 HID-C132 Car Position Indicator Handrail HR-01 CID-10 HR-02 CID-12 HR-04

Observation 1 Side View OA 01 OA 02 OA 03 2 Side View & 3 Side View OB 01 OC 01 OC 03 3 Side View OD 01 OD 02 1

Observation Round View OR 01 OR 02 OR 03 OR 04 OR 05 OR 0 Ceiling (Round View) OP 01D OP 02D OP 03D 17

Technical Data Passenger Hoistway & Machine Room Plan Hoistway Section [Simplex] [Duplex] Overhead, Pit & Machine Room Height Speed (m/s) 1.0 1.5 1.75 2.0 2.5 Load (kg) 4 ~ ~ 4 ~ ~ 4 ~ ~ 7 ~ 7 ~ Travel (m) Overhead (mm) PIt Depth (mm) Machine Room Height (mm) Hook Load (kg) TR TR 130 40 4400 4400 40 5 5300 1400 1400 14 10 1 1 20 2300 00 2300 00 2300 00 00 00 3000 40 3000 40 3000 40 40 40 1

Technical Data Passenger 19 [Standard] 9 10 13 17 24 Capacity Persons 4 5 00 0 7 13 Load(kg) Entrance Opening (mm) Car Size AN BN HoistWay Size Simplex Duplex Machine Room Size Simplex Duplex AH BH AH BH AM BM AM BM 300 40 40 4 52 57 1 12300 13 13 Machine Room Reaction Load(kg) R1 00 2 3 3400 3700 4 400 2 93 R2 49 700 7340 70 90 9430 10210 175 10 195 Pit R3 3930 5 0 370 930 74 010 13300 135 143 R4 1400 1400 1030 1400 1400 0 1400 13 13 10 1 10 00 13 1 1700 00 10 00 17 21 Outside Inside AS BS 14 10 14 95 14 14 14 14 1 1 190 90 35 190 90 90 1935 2240 175 1 10 1 1700 1 17 1 1 1 00 00 21 2400 22 0 2 2400 24 0 22 0 27 23 3 10 3 1700 3 17 3 1 3 00 4300 00 4300 21 00 22 5400 2 00 24 5400 22 5400 5700 23 1 10 1 1700 1 17 1 1 1 00 00 21 2400 22 0 2 2400 24 0 22 0 27 23 3 10 3 1700 3 17 3 1 3 00 4300 00 4300 21 00 22 5400 2 00 24 5400 22 5400 5700 23 1400 1400 1030 1400 1400 0 1400 13 13 10 1 10 00 13 1 1700 00 10 00 17 21 14 10 14 95 14 14 14 14 1 1 190 90 35 190 90 90 1935 2240 175 1 10 1 1700 1 17 1 1 1 00 00 21 2400 22 0 2 2400 24 0 22 0 27 23 3 10 3 1700 3 17 3 1 3 00 4300 00 4300 21 00 22 5400 2 00 24 5400 22 5400 5700 23 1 10 1 1700 1 17 1 1 1 00 00 21 2400 22 0 2 2400 24 0 22 0 27 23 3 10 3 1700 3 17 3 1 3 00 4300 00 4300 21 00 22 5400 2 00 24 5400 22 5400 5700 23 7 9 10 12 13 1 1 21 4 525 00 75 10 13 300 40 40 4 52 57 1 12300 13 13 00 2 3 3400 3700 4 400 2 93 49 700 7340 70 90 9430 10210 175 10 195 3930 5 0 370 930 74 010 13300 135 143 [EN Code] [Malaysia Code] Unit : mm 1400 1400 1030 1400 1400 0 1400 13 13 10 1 10 00 13 1 1700 00 10 00 17 21 14 10 14 95 14 14 14 14 1 1 190 90 35 190 90 90 1935 2240 175 1 10 1 1700 1 17 1 1 1 00 00 21 2400 22 0 2 2400 24 0 22 0 27 23 3 10 3 1700 3 17 3 1 3 00 4300 00 4300 21 00 22 5400 2 00 24 5400 22 5400 5700 23 1 10 1 1700 1 17 1 1 1 00 00 21 2400 22 0 2 2400 24 0 22 0 27 23 3 10 3 1700 3 17 3 1 3 00 4300 00 4300 21 00 22 5400 2 00 24 5400 22 5400 5700 23 9 10 13 17 23 4 545 0 7 5 1025 0 135 5 1.0 Speed (m/s) 1.0 1.0 300 40 40 4 52 57 1 12300 13 13 00 2 3 3400 3700 4 400 2 93 49 700 7340 70 90 9430 10210 175 10 195 3930 5 0 370 930 74 010 13300 135 143 Layout Dimensions (Speed : 1.0m/s)

Layout Dimensions (Speed : 1.5, 1.75m/s) Technical Data Passenger [Standard] 9 10 13 17 24 Capacity Persons 5 00 0 7 13 Load(kg) Entrance Opening (mm) Car Size AN BN HoistWay Size Simplex Duplex Machine Room Size Simplex Duplex AH BH AH BH AM BM AM BM 40 40 4 52 57 1 12300 13 13 Machine Room Reaction Load(kg) R1 2 3 3400 3700 4 400 2 93 R2 700 7340 70 90 9430 10210 175 10 195 Pit R3 5 0 370 930 74 010 13300 135 143 R4 1400 1030 1400 1400 0 1400 13 13 10 1 10 00 13 1 1700 00 10 00 17 21 Outside Inside AS BS 14 95 14 14 14 14 1 1 190 90 35 190 90 90 1935 2240 175 1 1700 1 17 1 1 1 00 00 21 2400 22 0 2 2400 24 0 22 0 27 23 3 1700 3 17 3 1 3 00 4300 00 4300 21 00 22 5400 2 00 24 5400 22 5400 5700 23 1 1700 1 17 1 1 1 00 00 21 2400 22 0 2 2400 24 0 22 0 27 23 3 1700 3 17 3 1 3 00 4300 00 4300 21 00 22 5400 2 00 24 5400 22 5400 5700 23 1400 1030 1400 1400 0 1400 13 13 10 1 10 00 13 1 1700 00 10 00 17 21 14 95 14 14 14 14 1 1 190 90 35 190 90 90 1935 2240 175 1 1700 1 17 1 1 1 00 00 21 2400 22 0 2 2400 24 0 22 0 27 23 3 1700 3 17 3 1 3 00 4300 00 4300 21 00 22 5400 2 00 24 5400 22 5400 5700 23 1 1700 1 17 1 1 1 00 00 21 2400 22 0 2 2400 24 0 22 0 27 23 3 1700 3 17 3 1 3 00 4300 00 4300 21 00 22 5400 2 00 24 5400 22 5400 5700 23 7 9 10 12 13 1 1 21 525 00 75 10 13 40 40 4 52 57 1 12300 13 13 2 3 3400 3700 4 400 2 93 700 7340 70 90 9430 10210 175 10 195 5 0 370 930 74 010 13300 135 143 [EN Code] [Malaysia Code] Unit : mm 1400 1030 1400 1400 0 1400 13 13 10 1 10 00 13 1 1700 00 10 00 17 21 14 95 14 14 14 14 1 1 190 90 35 190 90 90 1935 2240 175 1 1700 1 17 1 1 1 00 00 21 2400 22 0 2 2400 24 0 22 0 27 23 3 1700 3 17 3 1 3 00 4300 00 4300 21 00 22 5400 2 00 24 5400 22 5400 5700 23 1 1700 1 17 1 1 1 00 00 21 2400 22 0 2 2400 24 0 22 0 27 23 3 1700 3 17 3 1 3 00 4300 00 4300 21 00 22 5400 2 00 24 5400 22 5400 5700 23 9 10 13 17 23 545 0 7 5 1025 0 135 5 1.5 ~ 1.75 Speed (m/s) 1.5 ~ 1.75 1.5 ~ 1.75 40 40 4 52 57 1 12300 13 13 2 3 3400 3700 4 400 2 93 700 7340 70 90 9430 10210 175 10 195 5 0 370 930 74 010 13300 135 143

Technical Data Passenger Layout Dimensions (Speed : 2.0, 2.5m/s) [Standard] Unit : mm Speed (m/s) Persons Capacity Load(kg) Entrance Opening (mm) Car Size Inside Outside AN BN AS BS HoistWay Size Machine Room Size Simplex Duplex Simplex Duplex AH BH AH BH AM BM AM BM Reaction Load(kg) Machine Room Pit R1 R2 R3 R4 7 1400 13 1490 35 00 2 40 2 00 2 40 2 1 75 0 300 13 13 190 35 20 2 400 2 20 2 400 2 1 75 132 10 10 190 20 22 400 22 20 22 400 22 7 139 105 2.0 ~ 2.5 17 13 1 10 00 13 1 1700 00 10 190 90 35 190 90 2400 22 0 2 2400 24 0 22 00 22 5400 2 00 24 5400 22 2400 22 0 2 2400 24 0 22 00 22 5400 2 00 24 5400 22 12300 13 2 175 10 13300 135 24 00 17 21 90 1935 2240 175 0 27 23 5400 5700 23 0 27 23 5400 5700 23 13 93 195 143 [EN Code] 10 1400 13 1490 35 00 2 40 2 00 2 40 2 1 75 0 300 12 13 190 35 20 2 400 2 20 2 400 2 1 75 132 10 13 10 190 20 22 400 22 20 22 400 22 7 139 105 2.0 ~ 2.5 1 1 10 13 1 10 00 13 1 1700 00 10 190 90 35 190 90 2400 22 0 2 2400 24 0 22 00 22 5400 2 00 24 5400 22 2400 22 0 2 2400 24 0 22 00 22 5400 2 00 24 5400 22 12300 13 2 175 10 13300 135 21 00 17 21 90 1935 2240 175 0 27 23 5400 5700 23 0 27 23 5400 5700 23 13 93 195 143 [Malaysia Code] 7 1400 13 1490 35 00 2 40 2 00 2 40 2 1 75 0 300 13 5 13 190 35 20 2 400 2 20 2 400 2 1 75 132 10 1025 10 190 20 22 400 22 20 22 400 22 7 139 105 2.0 ~ 2.5 17 0 135 1 10 00 13 1 1700 00 10 190 90 35 190 90 2400 22 0 2 2400 24 0 22 00 22 5400 2 00 24 5400 22 2400 22 0 2 2400 24 0 22 00 22 5400 2 00 24 5400 22 12300 13 2 175 10 13300 135 23 5 00 17 21 90 1935 2240 175 0 27 23 5400 5700 23 0 27 23 5400 5700 23 13 93 195 143 21

Technical Data Observation Overhead, Pit & Machine Room Height Hoistway Section Speed (m/s) Overhead (mm) PIt Depth (mm) Machine Room Height (mm) 1.0 4300 17 1.5 40 1 0 1.75 400 00 1 Side View Observation Elevator Layout (OA) [Hoistway & Machine Room Plan] [Layout Dimensions] Speed (m/s) 1.0 ~ 1.75 Capacity Person 24 Load(kg) 7 13 Opening (mm) Inside Car Size Outside AN BN AS BS 1400 10 1700 1 13 1 1940 14 10 1790 190 55 105 05 2145 B1 25 5 12 HoistWay Size AH BH EE CB 23 2 2 19 20 2400 25 730 9 10 2 2 272.5 272.5 Machine Room Size Unit : mm Reactions(kg) AM BM R1 R2 23 2 2 19 20 2400 25 52 1 13 13 3700 400 93 22

Technical Data Observation 2 Side View Observation Elevator Layout (OB) [Hoistway & Machine Room Plan] [Layout Dimensions] Unit : mm Speed (m/s) 1.0 ~ 1.75 Person Capacity Load(kg) 7 13 Opening (mm) Inside Car Size Outside AN BN AS BS 1400 10 1700 13 1 14 90 1790 55 105 05 B1 25 955 1055 HoistWay Size AH BH EE CB 23 2 19 20 2400 730 9 2 272.5 272.5 Machine Room Size Reactions(kg) AM BM R1 R2 23 2 19 20 2400 57 12300 13 4 2 93 3 Side Rectangular Observation Elevator Layout (OC) [Hoistway & Machine Room Plan] [Layout Dimensions] Speed (m/s) 1.0 ~ 1.75 Person Capacity Load(kg) 7 13 Opening (mm) Inside Car Size Outside AN BN AS BS 1400 10 1700 13 1 14 90 1790 105 05 B1 25 955 1055 HoistWay Size AH BH EE CB 23 2 19 20 2400 730 9 2 272.5 272.5 Machine Room Size Unit : mm Reactions(kg) AM BM R1 R2 23 2 19 20 2400 57 12300 13 4 2 93 23

Technical Data Observation 3 Side Observation Elevator Layout (OD) [Hoistway & Machine Room Plan] [Layout Dimensions] Speed (m/s) 1.0 ~ 1.75 Capacity Person 24 Load(kg) 7 13 Opening (mm) Inside Car Size Outside AN BN AS BS 1400 10 1700 1 13 1 1940 14 10 1790 190 55 105 05 2145 B1 25 955 1055 1 HoistWay Size AH BH EE CB 23 2 2 19 20 2400 25 730 9 10 2 2 272.5 272.5 Machine Room Size Unit : mm Reactions(kg) AM BM R1 R2 23 2 2 19 20 2400 25 52 1 13 13 3700 400 93 Round Observation Elevator Layout (OR) [Hoistway & Machine Room Plan] [Layout Dimensions] Speed (m/s) 1.0 ~ 1.75 Capacity Person Load(kg) 7 13 Opening (mm) Inside Car Size Outside AN BN AS BS 1300 1400 10 0 13 1490 190 105 5 225 B1 25 955 1055 HoistWay Size R AH BH EE 700 23 2 20 2700 930 1030 CB 2 272.5 272.5 Machine Room Size B3 AM BM R1 10 1400 10 23 2 20 2700 57 12300 13 Unit : mm Reactions(kg) R2 4 2 93 24

Technical Data Entrance Details Narrow Jamb without Transom Panel [Section B-B] [Section A-A] [Front View of Entrance] [Building Structure Plan] Note 1. H dimension in building structure plan depends upon the type of hall indicator selected. 2. Unit : mm 25

Technical Data Entrance Details S-Type Wide Jamb with Transom Panel (with accentric line) [Section B-B] [Section A-A] [Front View of Entrance] [Building Structure Plan] Note 1. H dimension in building structure plan depends upon the type of hall indicator selected. 2. Unit : mm 2

Technical Data Entrance Details T-Type Wide Jamb with Transom Panel (with accentric line) [Section B-B] [Section A-A] [Front View of Entrance] [Building Structure Plan] Note 1. H dimension in building structure plan depends upon the type of hall indicator selected. 2. Unit : mm 27

Technical Data Passenger 2 Speed (m/s) Capacity Load(kg) Motor Capacity(kW) Simplex Duplex MCCB Capacity(A) Transformer Capa.(kVA) Lead-in Wire Size(mm 2 ) Simplex Duplex Simplex Duplex Earth Wire Size(mm 2 ) Starting Power(kVA/set) Persons 1.0 1.5 1.75 9 10 13 17 24 9 10 13 17 24 9 10 13 17 24 4 5 00 0 7 13 5 00 0 7 13 5 00 0 7 13 5.5 5.5 5.5 5.5 5.5.7.7 9.3.3.3.3.3 10 10 12 13.9 1.5 9. 9. 9. 9..7.7 14 1.2 19.3 35 35 35 40 0 0 0 0 0 0 0 0 0 0 0 0 0 1 1 0 0 2 1 1 0 0 225 2 1 1 1 25 25 25 32 40 40 25 25 32 32 32 40 3 32 32 32 40 40 3 3 32 32 32 40 3 3 0 3 3 3 0 3 3 3 0 0 140.0.0.2.9 7..4 9.1 10.9 12.3 14.1.1. 9.5 10.. 12..1 17.2 19. 9.9 10.5.5 13.1 14.1.3 17.3 19.7 22..9.9 12.5 13.. 1. 1.1 21.9 24.7 2.2 1.2 17.2 19.0 21.5 23.1 25.1 30.2 34.3 39. 19. 21.0 23.0 2.2 2.2 30. 34.5 39.3 45.3.0.0.0.0.0.0.0 1.0 1.0 1.0.0.0.0 1.0 1.0 1.0 22.0 22.0 22.0 1.0 1.0 1.0 1.0 1.0 22.0 22.0 22.0 3.0 1.0 1.0 1.0 1.0 1.0 1.0 22.0 22.0 3.0 3.0 22.0 22.0 22.0 22.0 22.0 3.0 3.0 3.0.0 22.0 3.0 3.0 3.0 3.0 3.0 3.0.0.0 4.0 4.0 4.0 4.0 4.0 4.0 4.0.0.0.0 4.0 4.0 4.0.0.0.0.0.0.0.0.0.0.0.0.0.0.0 1.0.0.0.0.0.0.0.0.0 1.0 1.0.0.0.0.0.0 1.0 1.0 1.0 25.0.0 1.0 1.0 1.0 1.0 1.0 1.0 25.0 25.0 45 75 0 975 45 1430 145 1930 225 0 140 17 1930 2145 245 295 3430 1375 10 1700 00 22 275 3375 4000 7.3 7.3 7.7.7 10.0 10.9.9 14.7 1. 19.5 10.5.2 12. 14.5.7 17.2 21.0 24.0 2.0 13.2 14.1. 1.0 19.5 21.3 24.2 27. 32.3 [Speed 1.0 ~ 1.75 m/s] Heat Output (kcal / H) Speed (m/s) Capacity Load(kg) Motor Capacity (kw) Simplex Duplex Simplex Duplex Simplex Duplex MCCB Capacity of Building(A) Power Supply Capacity(kVA) Lead-in Wire Size(mm 2 ) Earth Wire Size (mm 2 ) Heat Output (kcal / H) Starting Power (kva/set) Persons 2.0 2.5 13 17 24 13 17 24 7 13 7 13 13.5 13.5 1 1.5 22 13.5 17 17 23 27.5 0 0 75 75 175 1 40 40 0 75 0 75 75 1 175 0 225 1 1 175 0 225 300 75 1 1 175 13 14 1 1 21 25 1 1 23 2 31 25 27 31 3 42 31 35 39 45 52 2 3 3 3 3 3 3 3 3 3 14 14 14 14 0 0 0 1 0 1 1 14 14 14 22 30 3 14 22 22 30 3 3 14 14 14 14 225 2570 3300 30 4575 32 3575 40 425 57 25 27 29 32 3 41 32 35 3 42 47 54 [Speed 2.0, 2.5 m/s] 2V 400V 2V 400V Note 1. The wire size should be calculated considering the voltage drop when travel exceeds m. Power Supply Plan

Technical Data Passenger Technical Features [Operation Functions] Standard Option Features Attendant Operation Independent Operation Back-up Operation Safe Drive Operation Car Call Cancellation Automatic Turn-Off of Car Light & Fan Automatic Bypass Overload Holding Stop (0% of rated load) Detection of Jammed Hall Button Car Door Safety Edge Micro Levelling N-Plex Operation Non-Stop Operation Parking Operation VIP Operation Emergency Power Operation Fire return operation Firemen Operation Anti-nuisance Operation Door Nudging Voice Synthesizer Door Photo Sensor Description The operating mode of an elevator can be changed from the normal automatic operation to the attendant service by an attendant switch. Key switch in the car operating panel will cancel any existing car calls and hold the door open at the landing position. During independing operation, the car will respond only to car calls. When Electrical transmission device between hall call and control panel comes into the abnormal condition and it lasts during some period, elevator control device is converted to Back-up operation automatically. Then, the elevator moves in sequence up and down repeatedly from top to bottom floor to service every other floor which is in normal condition. When a car stops between floors due to mechanical malfunction, it will descend to the nearest floor at a low speed and hold the doors open after checking all safety measures. Allows cancellation of an incorrectly registered car call. If you push a wrong floor button in the car, you can cancel it by pressing that floor button one more time. Car illumination and fan are turned off automatically in case there is no hall call or car call, this saves energy. A fully-loaded car ( More than 0% of rated load) bypasses hall calls in order to maintain maximum operational efficiency. When the number of passengers exceeds the normal capacity, a buzzer sounds and the elevator remains stopped at that floor. When the excessive number of passengers disembark, the buzzer stops, the elevator doors close, and operation continues. If a hall button is jammed mechanically, the hall call will be automatically bypassed after being served once, until the program is resolved. Extending the full height of the car door, this decice causes the doors to return to the fully open position, should the door encounter a person or obstacle while closing. An automatic two way levelling device is provided to maintain the elevator car level with the landing, regardless of elevator load or direction of travel. It can control up to 4 sets of elevators to optimize allocation of hall calls. Specific floors which are memorized in control panel can be set to disable using switch on car operating panel or in security room. The elevator can be automatically parked at the predetermned floor with its door closed, as well as turn off the lights and ventillation. The specified elevator is controlled by the special call buttons provided only for VIP elevator If normal building power supply fails and the building provides emergency power to the controller(s), one elevator at a time will proceed to the lowest landing where it will stop with doors open and with all of its power and operating circuit in an inoperative standby condition. In case of fire, every car should be returned to the specified floor in order to evacuate pasengers to safety. In case of fire, a firemen can use the elevator which is stopped at the specified floor in order to support firemen for fire-fighting. In case of substantial difference between the number of calls registered on the car operating panel and actual load in the elevator, the elevator prevents unnecessary operation by cancelling all registered calls when it arrives at the nearest floor. When the doors remain open for more than the fixed door open time, this feature closes the doors at reduced closing speed with the buzzer sounding. This system provides riding passengers with audio information about car operation such as direction of travel, landing floor, etc. The doors reverse to fully open position if the light ray unit detects an obstacle when the doors are closing. 29

Technical Data Work by Others The works below are not included in the elevator installation work and should be carried out by building contractors in accordance with our drawings, relevant international or local codes and regulations. Hoistway A properly framed and enclosed hoistway, including any venting as requried by the governing code or authority. A dry pit constructed to the elevator manufacturer's specifications to reinforce or sustain any vertical forces on the guide rails and impacted loads from the car and counterweight buffers. A metal sill angle or concrete haunch across the full width of the hoistway at each elevator landing. Provision of steel bars to fix jamb around the entrance of each floor. All cutting, including cutouts to accommodate hall singal fixtures, patching, painting of walls, floors, or partitions, together with finish painting of entrance doors and frames, if required. Provision of entrance or ladder for pit access Supply and installation of fascia plate. Installation of emergency exits and electric wiring in blind sections of hoistway where required. The tolerance of perpendicular line over the whole hoistway height must not exceed ±30mm. A waterproof outlet and light fixture in the elevator pit area with the light switch being located adjacent to the access door or ladder. Suitable light fixture and convenience outlet in the pit with a light switch adjacent to the access door or ladder. The receptacles shall have protection for ground fault circuit interrupter. Machine Room Provision of wiring between controller and building management system. A construction hoisting beam or hook, if required, with the correct location and size as determined by the elevator contractor for each hoistway. Noise insulation should be installed between machine room and adjacent residential area. A suitable machine room with legal access, ventilation and concrete floor. The temperature in the machine room should be maintained between 5 and 40. Relative humidity should not exceed 90%(monthly) and 95%(daily) non-condensing. Ventilation fan or Air conditioner should be provided as per heat dissipation by the elevator contractor. The size of entrance shall be Min.mm(W) x 00mm(H). Installation of lead-in wire and earth wire between building main power board and machine room incoming distribution board. However, machine room lighting source supply shall be installed separately. Provision of suitable light fixture and convenience outlets in the machine room Miscellaneous Wiring and piping between monitoring system. Machine room and hoistway shall be free of dust or harmful gas. All electric power for lighting, tools, welding, etc during installation. All single phase receptacles installed in machine rooms, pits, and machinery spaces shall have ground fault circuit interrupter protection. Fire detector for fire emergency operation. A secured area for stroage of elevator equipment and materials during installtion. 30

SIGMA constantly endeavors to improve products so that information in this catalog is subject to change without notice. 0. 12 Printed in Korea / Revision No. 1