Type MMV-WP Medium Voltage Wind Power Cable

Similar documents
Gexol. Gexol. World Class Oil & Gas Cables. The Global Cable Solutions Company

Easier! Faster! Safer!

Control Cable Type T/N 600/1000 volts DRILMAR 90 Polyvinyl Chloride/Nylon Insulated Drilling Rig and Marine Cable

Type P Drilmar 125-XE Signal & Instrumentation

Type P Drilmar 125-XE Signal & Instrumentation

Control Cable Type P 600/1000 volts DRILMAR 125-XE Crosslinked Polyolefin Insulated Drilling Rig and Marine Cable

Type P Drilmar 125-XE Power/Distribution Cable Multiconductor

MEDIUM VOLTAGE

Corflex. Continuous Corrugated Aluminum Sheathed PL, MC and MV Industrial Cables. Introduction Applications... 3

Automotive Cables. The Global Cable Solutions Company

TUNNELING POWER CABLES

Section 11 Mining Cable

DLO. Mining Cable. Mining Cable. 2 kv

INDUSTRIAL GRADE HIGHLY DURABLE, EASY STRIPPING PORTABLE POWER CABLES

DRILL CORD. Insulation Nominal Size. Approximate Amps Anixter. Number Number Thickness O.D.

TC-THHN/THWN-2 Copper, PVC/Nylon Insulated

TC-XHHW-2 Copper, XLPE Insulated, PVC Jacketed

High Voltage Copper, Smooth Aluminum Shield/Sheath

TC-XHHW-2 Copper, XLPE Insulated, PVC Jacketed

TC-THHN/THWN-2 Copper, PVC/Nylon Insulated

TC-RHH/RHW-2 USE-2 Copper

LCT Shielded Primary UD EPR LCT Shielded Primary UD EPR Cable

MC or MV-105 Copper, TR-XLPE Insulated

High Voltage Aluminum, Smooth Aluminum Shield/Sheath

C-L-X Aluminum Sheath Type IEC

E R C. R E R C ; ; W T E C

INDUSTRIAL

Introduction. Phone (888) Fax (800) Int l Phone Int l Fax

Okoguard -Okoseal Type IEC

CORFLEX. Continuous Corrugated and Welded, Impervious Aluminum Sheathed PL, MC and VFD Industrial Cables. Introduction Applications...


IEEE 1580 TYPE T/N CABLE

0.6/1KV FLAME RETARDANT ARMORED & SHEATHED CABLE PRODUCT CONSTRUCTION 1. CONDUCTOR

LCT Shielded Primary UD TRXLP LCT Shielded Primary UD TRXLP Cable

Medium Voltage Cables for PermaLife Nuclear Utility Applications

ÖLFLEX VFD 2XL - screened VFD cable for fixed installation or occasional flexing with UL TC-ER.

Introduction. Nexans wire and cable. Contact us for all your wire and cable needs

UNSHIELDED MULTI CONDUCTOR

Omni Cable is a master distributor of specialty wire and cable selling

FlexFlame BFOU(i) 150/250(300)V S3/S7 Instr. cable

INDUSTRIAL SOLUTIONS MARINE CATALOGUE INNOVATIVE CABLE SOLUTIONS MEETING INTERNATIONAL STANDARDS

FlexFlame RFOU(i) 150/250(300)V S1/S5 Instr. cable

Marine Wire and Cable

ANSI/NEMA WC ICEA No. S Portable and Power Feeder Cables for Use in Mines and Similar Applications

TRATOS OIL&GAS NEK606

Global data. Electrical parameters

0.6/1KV FLAME RETARDANT UNARMORED CABLE PRODUCT CONSTRUCTION 1. CONDUCTOR CROSS-LINKED POLYETHYLENE (XLPE) IEEE 1580 COLOR CODE 3.

Electronic Instrumentation

4. SHIELDS. 4.1 Power Cable. 4.2 Electronic Cable Conductor Shield (Strand Shield) Outer Shield (Insulation Shield) 60

TECHNICAL GUIDELINE. Medium Voltage Conductor Ampacities ALUMINUM COPPER. Single Conductor 5kV - 35kV

Standardization IEC /-351/-353. Conductor material

Unarmoured Single-Core Cables to BS6883

3M Cold Shrink QS-III Inline Splice Kits 15 kv 5513A, 5514A, 5515A and 5516A

Detailed Specifications & Technical Data

Variable Frequency Drive (VFD) Cable Solutions

QS-III. 5513A, 5514A, 5515A and 5516A 15 kv Cold Shrink Inline Splice Kits. Data Sheet CAUTION. 1. Product Description. 2. Applications.

FlexFlame BFOU-XFR(i) 150/250(300)V Instr. cable. Standards applied. IEC EN 50200:2006 Annex E

CABLED TWISTED PAIRS CONDUCTORS

Wired for Power Generation

TABLE OF CONTENTS Page

BFOU 0.6/1kV Power Cable

Installation device. HelaTape. Electrical tapes for sealing, insulation and bundling of cable and conduits.

Rail & Transit WIRE AND CABLE

CRANE, CONVEYOR, LIFT & REELING CABLES

SOOW 90 C. Portable Cord. Portable Cord 10.2 SOOW 90 C

Section 8. Portable Cordage & Power Cable

MC, THHN/THWN-2 Copper

Data sheet E-DAT Industry patch cord V6 IP67 - RJ m

The Best Flexible Wire Replacement with ERIFLEX FLEXIBAR STANDARD and ERIFLEX FLEXIBAR SUMMUM

CABLED SINGLE CONDUCTORS

RFOU 0.6/1kV Power Cable

3M Cold Shrink 3-Conductor Inline Splice Kits QS-III 5786A- MT, 5787A-MT and 5788A-MT 25/28 kv for use with Armored and Non- Armored 3/C Cable

6000 Series Ethernet Buccaneer

PRODUCT INFORMATION ÖLFLEX HEAT 125 C MC. Info Improved characteristics in the event of a fire GL - Germanischer Lloyd approved

Airfield Ground Lighting

Electrical connection systems

Ethernet Buccaneer BUCCANEER DATA. bulgin

Harnessing the wind of change. Our cables supply societies with renewable energy.

A. General: Deliver, store and handle wire and cable in accordance with the manufacturer's instructions and as specified in Division 1.

TECSUN (UL) PV1-F Halogen - free TÜV + UL dual rated PV-Wire

ULTROL Still ahead of its time after 30 years Class 1E nuclear rated cable

UF103WG250 10/3 WG Uf Cable-250' Features. Material, Color, and Finish. Dimensions and Weight

20 HUBER+SUHNER RADOX SOLAR

Southwire Company. Current Rating 70 AMPERE (60 DEG C), 85 AMPERE (75 DEG C), 95 AMPERE (90 DEG C) Ground Conductor Size

Ethernet Buccaneer IP68 BUCCANEER FOR DATA BUCCANEER DATA

ÖLFLEX CLASSIC 135 CH -halogen-free control cable, HFFR, flexible and screened for various applications, U 0 /U: 300/500V

Power & Control Cable IEC

Installation Devices 4

is the UK subsidary of Tele-Fonika Kable S.A., with offices and a warehouse centrally located in Leicestershire.

Data sheet chainflex CF8821

Data sheet chainflex CF881

VDE-registered oil-resistant PVC control cable with black outer sheath for a wide range of applications

PPT 802, Proximity Probe Transducer System

grounded in service wired to innovate STABILOY Type XHHW-2 and USE-2/RHH/RHW-2

Data sheet chainflex CF240

Coupling ring, screw thread provides secure cable coupling. Shielded Cat 5e coupler maintains screening. Retaining Nut

OFFSHORE WIND FEASIBILITY STUDY APPENDICES Appendix C.2 Subsea Cable Data Sheets

Identification Type SU+M(C)P SE(4G1,5+(2 0,75)+(2 AWG22))UL 1KV OR. Part-No

Data sheet chainflex CF886

PVC Insulation with Nylon Jacket. Solid or Stranded Soft-annealed Uncoated Copper

Transcription:

WP Type MMVWP Medium Voltage Wind Power Cable ThreeConductor: 5kV & 5kV, % Rated 05 C Renewable Energy Cables Conductors Soft annealed flexible stranded tinned copper per IEEE 580 Table and UL 07 Insulation Extruded thermosetting 05 C Ethylene Propylene Rubber (EPR), meeting UL 09 (Type E), IEEE 580 (Type E), ICEA S6856 and UL 07. Metallic Shield Composite shield consisting of tinned copper braid with nylon providing 60% copper coverage meeting UL 09, IEEE Std. 580, ICEA S6856 and UL 07. The nylon is colored for easy phase identification (three conductor = black, blue, red) without the need to remove the shield to find an underlying colored tape. Conductor Shield A combination of semiconducting tape and extruded thermosetting semiconducting material meeting UL 09, IEEE 580, ICEA S6856 and UL07. Insulation Shield Semiconducting tape, with overlap, for fast and easy termination meeting UL 09, IEEE 580, ICEA S6856 and UL 07. Grounding Conductor (optional) One uninsulated soft annealed flexible stranded tinned copper conductor per ASTM B and sized according to Table. of UL 07. Jacket Black, arctic grade, flame retardant, oil, abrasion, chemical and sunlight resistant thermosetting compound meeting UL 09, IEEE 580, ICEA S6856 and UL 07. Jacket is two layer reinforced on multiconductor constructions. Colored jackets for signifying different voltage levels are also available on special request (ie. yellow = 5kV and red = 5kV). Ratings & Approvals UL Listed as Marine Shipboard Cable (E6) UL Listed as NEC Type MV05 (E65) American Bureau of Shipping (ABS) Det Norske Veritas (DNV) 05 C Temperature Rating Voltage Rating: 5kV & 5kV Torsional Rating: +/ 7 /ft Termination Kits AmerCable recommends Raychem s HVTM series terminations for multiconductor constructions. Hawke Gland Types Hawke P/N Industrial & Safe Area (IP68) Increased Safety EExe / Explosion Proof Class I, Div. Class I, Zone Flameproof / EExd Zone & Applications AmerCable s Type MMVWP wind power medium voltage cables are for use as the service loop (drop) cable on the output side of the wind turbine generator at temperatures from 0 C to +05 C. Features Carries both NEC markings for onshore applications and marine markings for offshore applications. Two layer, reinforced thermoset jacket resists torsional movement. Withstands greater than 0,000 cycles of twist, degrees in both directions. These cables utilize flexible stranded conductors and braided shields which make them very suitable for applications involving repeated flexing and twisting. These cables have a small minimum bending radius (6xOD) for easy installation. Optional uninsulated grounding conductors sized per UL 07. The increased flexibility of this cable allows for termination of one end and coiling in the nacelle. Then coiling and terminating other end when nacelle is mated with the tower, thereby reducing installation time. Passes IEC Category A and IEEE 0/UL 58 flame tests. www. amercable.com email: greencable@amercable.com

WP Type MMVWP Medium Voltage Wind Power Cable ThreeConductor: 5kV & 5kV, % Insulation Level. Rated 05 C Renewable Energy Cables Three Conductor Type MMVWP 5kV, 00/% Insulation Level Single Banked Inductive Maximum Size Nominal Weight In Free (No Spacing) DC Resistance AC Resistance Reactance Voltage Drop Optional Suspended AWG/ Part No. Diameter (Lbs./ Air in Trays at 5 C at 90 C, 60Hz (ohms/ (Volts per amp Grounding Length kcmil mm (inches) 000 ft.) (amps) (amps) (ohms/000 ft.) (ohms/000 ft.) 000 ft.) per 000 ft.) Conductor (ft.) /0 /0 6 7 5 66 777 0 85 0 00 00 06WP 07WP 08WP 09WP 0WP WP WP WP WP WP 6WP.6.90.7.5.686.8.966..6.5.75 0 9 787 55 558 5966 676 807 90 05 9 0 66 06 8 86 9 55 58 58 67 7 97 6 60 96 8 65 87 9 96 5 0.7 0.09 0.07 0.058 0.08 0.00 0.0 0.08 0.0 0.00 0.06 0.7 0.7 0.09 0.06 0.05 0.08 0.05 0.0 0.0 0.0 0.00 0.09 0.09 0.08 0.08 0.07 0.07 0.9 0.96 0.6 0.6 0.8 0.0 0.09 0.08 0.07 0.067 0.06 /0 0 66 0 55 7 97 50 55 585 Three Conductor Type MMVWP 5kV, % Insulation Level Single Banked Inductive Maximum Size Nominal Weight In Free (No Spacing) DC Resistance AC Resistance Reactance Voltage Drop Optional Suspended AWG/ Part No. Diameter (Lbs./ Air in Trays at 5 C at 90 C, 60Hz (ohms/ (Volts per amp Grounding Length kcmil mm (inches) 000 ft.) (amps) (amps) (ohms/000 ft.) (ohms/000 ft.) 000 ft.) per 000 ft.) Conductor (ft) /0 /0 7WP 8WP 9WP 60WP 6WP 6WP.57.558.7.87.96.59 076 69 59 60 56 78 05 69 09 5 7 99 9 6 0.8 0.7 0.7 0.09 0.07 0.058 0.0 0.8 0.7 0.7 0.09 0.0 0.0 0.0 0.07 0.6 0.99 0.6 0.0 0. 0. 6 80 6 7 69 9 Ordering Type MMVWP Medium Voltage Cables Example: conductor power cable 5kV % # AWG Ground 7 05 7WP G AmerCable Type MMV Prefix Specific Cable Number (from charts) Ground Conductor G with ground Blank no ground SAVE TIME SAVE MONEY Order Your Cable with Factory Installed Termination Kits and Lugs Manufactured by AmerCable Incorporated 800697 78965800 Fax: 7899009

WP Type MMVWP Medium Voltage Wind Power Cable Single Conductor: 5kV, 5kV & kv Rated 05 C Renewable Energy Cables Conductors Soft annealed flexible stranded tinned copper per IEEE 580 Table and UL 07 Insulation Extruded thermosetting 05 C Ethylene Propylene Rubber (EPR), meeting UL 09 (Type E), IEEE 580 (Type E), ICEA S6856 and UL 07. Metallic Shield Composite shield consisting of tinned copper braid with nylon providing 60% copper coverage meeting UL 09, IEEE Std. 580, ICEA S6856 and UL 07. Conductor Shield A combination of semiconducting tape and extruded thermosetting semiconducting material meeting UL 09, IEEE 580, ICEA S6856 and UL07. Insulation Shield Semiconducting tape, with overlap, for fast and easy termination meeting UL 09, IEEE 580, ICEA S6856 and UL 07. Jacket Black, arctic grade, flame retardant, oil, abrasion, chemical and sunlight resistant thermosetting compound meeting UL 09, IEEE 580, ICEA S6856 and UL 07. Colored jackets for signifying different voltage levels are also available on special request (ie. yellow = 5kV, and red = 5kV & kv). Ratings & Approvals UL Listed as Marine Shipboard Cable (E6) UL Listed as NEC Type MV05 (E65) American Bureau of Shipping (ABS) Det Norske Veritas (DNV) 05 C Temperature Rating Voltage Rating: 5kV, 5kV & kv Torsional Rating: +/ 7 /ft Termination Kits AmerCable recommends Raychem s HVT series terminations for singleconductor constructions. Hawke Gland Types Hawke P/N Industrial & Safe Area (IP68) Increased Safety EExe / Explosion Proof Class I, Div. Class I, Zone Flameproof / EExd Zone & Applications AmerCable s Type MMVWP wind power medium voltage cables are for use as the service loop (drop) cable on the output side of the wind turbine generator at temperatures from 0 C to +05 C. Features Carries both NEC markings for onshore applications and marine markings for offshore applications. Withstands greater than 0,000 cycles of twist, degrees in both directions. These cables utilize flexible stranded conductors and braided shields which make them very suitable for applications involving repeated flexing and twisting. These cables have a small minimum bending radius (6xOD) for easy installation. The increased flexibility of this cable allows for termination of one end and coiling in the nacelle. Then coiling and terminating other end when nacelle is mated with the tower, thereby reducing installation time. Passes IEC Category A and IEEE 0/UL 58 flame tests. www. amercable.com email: greencable@amercable.com

WP Type MMVWP Medium Voltage Wind Power Cable Single Conductor: 5kV, 5kV & kv Rated 05 C Renewable Energy Cables Single Conductor Type MMVWP 5kV, 00/% Insulation Level Diameter DC Inductive Maximum Size Over Nominal Weight In Free Triangular Single Banked Resistance AC Resistance Reactance Voltage Drop Suspended AWG/ Part No. Insulation Diameter (Lbs./ Air Configuration in Tray at 5 C at 90 C, 60Hz (ohms/ (Volts per amp Length kcmil mm (inches) (inches) 000 ft.) (amps) (amps) (amps) (ohms/000 ft.) (ohms/000 ft.) 000 ft.) per 000 ft.) (ft.) /0 /0 6 7 5 0 85 0 0WP 05WP 06WP 07WP 08WP 09WP 0WP WP WP WP WP 0.560 0.597 0.69 0. 0.755 0.80 0.899 0.9.06.08.6 0.765 0.805 0.89 0. 0.9.057.6.0.67.. 58 59 67 80 98 08 97 96 76 007 0 86 7 85 8 8 86 5 606 68 59 8 8 7 60 5 58 8 0 79 6 55 580 0.75 0.0 0. 0.089 0.0 0.056 0.06 0.0 0.07 0.0 0.0 0.8 0.7 0.7 0.09 0.06 0.05 0.0 0.00 0. 0.0 0.0 0.0 0.0 0.0 0.6 0.96 0.5 0.0 0.78 0. 0. 0.08 0.0 0.086 0.077 80 576 56 58 60 60 6 6 690 5kV, % Insulation Level Diameter DC Inductive Maximum Size Over Nominal Weight In Free Triangular Single Banked Resistance AC Resistance Reactance Voltage Drop Suspended AWG/ Part No. Insulation Diameter (Lbs./ Air Configuration in Tray at 5 C at 90 C, 60Hz (ohms/ (Volts per amp Length kcmil mm (inches) (inches) 000 ft.) (amps) (amps) (amps) (ohms/000 ft.) (ohms/000 ft.) 000 ft.) per 000 ft.) (ft.) /0 /0 6 7 5 0 85 0 6WP 65WP 66WP 67WP 68WP 69WP WP 7WP 7WP 7WP 7WP 0.80 0.85 0.905 0.96.008.07.59.0.6.6..7.85.0.88..5.9.560.65.76.89 786 880 989 9 90 9 75 59 97 86 7 8 7 78 8 56 598 67 6 89 7 88 77 8 6 5 57 58 8 0 78 66 09 56 8 57 0.75 0.0 0. 0.089 0.0 0.056 0.06 0.0 0.07 0.0 0.0 0.8 0.7 0.7 0.09 0.06 0.05 0.0 0.09 0.07 0.0 0.0 0.00 0.07 0. 0.05 0.5 0.09 0.76 0.8 0.9 0. 0.0 0.09 0.08 5 88 6 66 7 60 90 55 59 58 kv, 00% Insulation Level Diameter DC Inductive Maximum Size Over Nominal Weight In Free Triangular Single Banked Resistance AC Resistance Reactance Voltage Drop Suspended AWG/ Part No. Insulation Diameter (Lbs./ Air Configuration in Tray at 5 C at 90 C, 60Hz (ohms/ (Volts per amp Length kcmil mm (inches) (inches) 000 ft.) (amps) (amps) (amps) (ohms/000 ft.) (ohms/000 ft.) 000 ft.) per 000 ft.) (ft.) /0 /0 6 0 80WP 8WP 8WP 8WP 8WP 85WP 86WP 87WP.080..7.6.76...69.89.8..5.600.665.80.85 07 68 85 588 797 5 8 09 78 9 7 67 67 9 0 88 76 6 55 78 05 6 7 8 97 0.75 0.0 0. 0.089 0.0 0.056 0.06 0.0 0.8 0.7 0.7 0.09 0.06 0.05 0.055 0.05 0.05 0.0 0.08 0.06 0.0 0.75 0.0 0.57 0. 0.80 0.5 0. 0.8 90 7 89 9 9 0 Manufactured by AmerCable Incorporated 800697 78965800 Fax: 7899009

Renewable Energy Cables Individual Closest Uninsulated Size Size Number Strand Dia. IEEE 5 Conductor AWG/kcmil mm of Strands (inches) Std. Size Dia. (inches) /0 /0 6 7 5 66 777 MMVWP Stranding Profile 0 85 0 00 00 09 66 8 5 66 777 0 59 9 0.0 66 8 06 68 6 7 5 66 777 0. 0.6 0.07 0.6 0. 0.575 0.65 0. 0.785 0.860 0.9.09. MMVWP Ampacities & Electrical Data Ampacities are based on API RP F (June 999) Table. Ampacities are based on a 90 C conductor temperature and a 5 C ambient temperature. The 05 C ampacities from this table may be used as permitted. Ampacities covered by NEC article 8.80 may also be used (90 C or 05 C as permitted). Inductive reactance and voltage drop values are based on a 90 C conductor temperature and 60 Hz operation. Please consult AmerCable on values based on other parameters. www. amercable.com email: greencable@amercable.com

Some medium voltage cables offered to the wind power industry have only an extruded semiconducting insulation shield. The AmerCable MMVWP cable utilizes an extruded semiconducting layer AND a metallic component in the insulation shield. Here s why... Safety the metallic component withstands the high heat of a short circuit current so the circuit can be safely deenergized. LongTerm Shield Effectiveness the metallic component maintains its electrical properties throughout the life of the cable. EMI Shielding there must be a metallic component present to provide EMI shielding. Required by U.S. Regulations all U.S. standards covering cables rated above 5kV require a metallic component in the insulation shield. These standards include: U.S. National Electrical Code (NFPA ), UL 07, Medium Voltage Power Cables, AEIC CS8, Specification for Extruded Dielectric Shielded Power Cables Rated 5 6kV, ANSI/ICEA S9768, Standard for Utility Shielded Power Cables Rated 5 6kV, UL 09, Marine Shipboard Cable, IEEE Std. 580, Recommended Practice for Marine Cables for Use on Shipboard and Fixed or Floating Platforms. For safety, performance and compliance, you can depend on AmerCable MMVWP cables!

Renewable Ener gy Cables AmerCable manufactures high quality jacketed electrical cables for a wide variety of specialized renewable energy, utility and industrial applications. AmerCable is an ISO 900 certified cable manufacturer that combines leadingedge technology, proven manufacturing techniques, and high quality service to deliver the finest cable and cable assembly products available. El Dorado, Arkansas AmerCable s manufacturing facility and corporate headquarters in El Dorado, Arkansas. What can you expect from AmerCable? 䡲 High Quality Cable 䡲 OnTime Delivery* 䡲 Professional Sales, Support and Service 䡲 Strategic Inventory Locations 䡲 Operational Excellence 䡲 Short Lead Times * Check www.amercable.com for our most current ontime delivery record Made in America Utility and Industrial Cables: DLO Type SH Grounds Jumpers Portable Power Top Drive Service Loops The industry standard for flexible, high performance power, control and instrumentation Type P cables. Solar/PV Cables: 000V UL standard 06 West Little York Building # Suite #00 Houston, TX7 USA (7) 8965800 (800) 697 Fax (7) 899009 email: greencable@amercable.com www.amercable.com 009, AmerCable Incorporated Low smoke halogenfree fire resistant or flame retardant Type P cables. Foil shielded, power cables engineered for use in variable frequency AC drive applications. Available in several constructions _09