Blank-off. HVAC unit screws. Spacer for 1" filter ILL. 3. Screw

Similar documents
Screw. (Note 4) Spacer for 1" filter ILL. 3. Screw

Screw. (Note 4) Spacer for 1" filter ILL. 3. Screw

ILL. 1. Horizontal. supply air cover panel shipped on HVAC unit. Access door/ panel

Installation Manual. Mixing Box Control Systems Installation, Operation, and Maintenance Manual. 605 Shiloh Road Plano, Texas

INSTALLATION INSTRUCTION

Package Unit Modulating Economizer Installation Instructions

Installation Instructions

Package Unit Modulating Economizer Installation Instructions

Installation Instructions

Installation Instructions

Installation Instructions

Installation Instructions

ECONOMIZERS. 5/2012 Supersedes

ECONOMIZERS. 1/2012 Supersedes

Installation Instructions

CRECOMZR054B00 CRECOMZR055B00. VERTICAL AND HORIZONTAL ECONOMI$ER2 ACCESSORY MEDIUM ROOFTOP UNITS 15 to 27 1/2 TONS WARNING TABLE OF CONTENTS

Installation Instructions

Library Product Section Product Model Literature Type Sequence Date File No. Supersedes

MicroMetl INSTALLATION INSTRUCTIONS FOR 0689ZJ36EC

COMMERICAL SPLIT SYSTEM KITS AND ACCESSORIES /2014 Supersedes 8/2012

Installation Instructions

Installation Instructions DNECOMZR020A02, DNECOMZR021A03 (For 3 to 12.5 Ton Units) and DNECOMZR062A00 (For RHS 12.5 Ton Heat Pump Units)

Installation Instructions

Installation Instructions

Installation Instructions

INSTALLATION INSTRUCTIONS COMMERCIAL ROOM VENTILATORS WITH EXHAUST

CAUTION Danger of sharp metallic edges. Can cause injury. Take care when servicing unit to avoid accidental contact with sharp edges.

Installation Instructions

INSTALLATION INSTRUCTIONS COMMERCIAL ROOM VENTILATORS WITH EXHAUST. For Use with Bard C**H Series 2 & 2½ Ton 2-Stage Wall Mount Heat Pumps

INSTALLATION INSTRUCTIONS MODELS (-)XRD-MCCM3 & (-)XRD-MECM3/TECM3 CONVERTIBLE AIRFLOW ECONOMIZERS

INSTALLATION INSTRUCTIONS COMMERCIAL ROOM VENTILATORS WITH EXHAUST. For Use with Bard CH Series 3, 4, & 5 Ton Wall Mount Heat Pumps

EconoMi$er, Power Exhaust, and Sensor Installation Instructions

Installation Instructions

INSTALLATION INSTRUCTIONS COMMERCIAL ROOM VENTILATORS WITH EXHAUST. For Use with Bard 2 2-1/2 Ton Wall Mount T Series Heat Pumps

Installation Instructions

INSTALLATION INSTRUCTIONS MODELS (-)XRD-PDCM3 & (-)XRD-SDCM3 VERTICAL AIRFLOW ECONOMIZERS

INSTALLATION INSTRUCTIONS

LF24-ECON-R03(-R10) US Operation, Installation and Wiring

wiring diagrams SINGLE PACKAGE ROOFTOP GAS HEATING/ELECTRIC COOLING UNITS

LF Series At A Glance

INSTALLATION INSTRUCTIONS MODELS (-)XRD-RGCM3 HORIZONTAL AIRFLOW ECONOMIZERS

R81EAA-2 Economizer Circuit Board

MicroMetl. INSTALLATION INSTRUCTIONS Dual Stage Relief Economizer ECD-SRT12DR, ECD-SRT34DR, ECD-SRT5SDR & ECD-SRT5LDR

ZIP Economizer Fault Detection and Diagnostics (FDD) Table

TROUBLESHOOTING GUIDE FOR HEAT PUMP BOOSTERS MODELS: HPB11, HPB15, & HPB22

Installation Instructions

Installation Instructions

PERFECT FIT SERIES IN-DASH HEAT/ COOL/ DEFROST 1969 CHEVROLET CAMARO/ FIREBIRD NOTE: INSTRUCTIONS DEPICT CAMARO

ACCESSORY KIT INSTALLATION INSTRUCTIONS

THC-2, THC-3, THCR-4, THCR-5. Enthalpy Control. General Instructions APPLICATION SPECIFICATIONS. ACCESSORIES None

SLIMZONE CLASSIC /


PERFORMANCE DATA TYPICAL FIELD WIRING CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS

INSTALLATION INSTRUCTIONS

& 76 CHEVROLET NOVA HEATER ONLY

Installation, Operation and Maintenance Manual

Mount directly to 1.05 jackshafts. AF230 US (p. 02) AF230-S US (p. 20) AF24-S US (p. 18)

INSTRUCTIONS FOR (-)XRX-AW04 or (-)XRX-AW05 MOTORIZED FRESH AIR DAMPER KIT

Installation Instructions

R81EAA Type Plug-In Electronic Circuit Board Kit For Series M100 Motor Actuators

LF Series Spring Return Direct Coupled Actuator

Installation Guide. DigiTract 4. Two Stage Heat/Cool Comfort Control System. Zoning Systems. That s all we do. Part #DT4MAN. Rev.

PERFORMANCE DATA TYPICAL FIELD WIRING CERTIFIED DIMENSION PRINT CERTIFIED ROOF CURB DIMENSION PRINTS

CHP

ERV ENERGY RECOVERY VENTILATOR 60 HZ. Indoor / Outdoor 500 to 10,000 cfm Capacity ERV I - D - D - P - 1 MODEL NUMBER IDENTIFICATION

CPC Series. Submittal Data Form. 15- & 20-Ton Self-Contained. Packaged Air Conditioner. with R-410A

INSTALLATION INSTRUCTIONS

SUNLINE 2000 SINGLE PACKAGE AIR - TO - AIR HEAT PUMPS DESCRIPTION. B1CH 180 & and 20 NOMINAL TONS ( EER)

SUNLINE 2000 TM TECHNICAL GUIDE DESCRIPTION SINGLE PACKAGE AIR-TO-AIR HEAT PUMPS

Installation Instructions

NSGV PT-1000 PORTABLE WELDING STATION I, O & M MANUAL

Installation Guide. DigiTract 4. Two Stage Heat/Cool Comfort Control System. Zoning Systems. That s all we do. Part #DT4MAN Rev.

MA-5200 Series MA-5300 Series

IMPORTANT ATTENTION INSTALLERS:

Instruction Manual for Barber-Colman Series EA Electric High Torque Actuators

TOP-MOUNT REFRIGERATOR. Frigidaire P.O. BOX 8020 CHARLOTTE, NC Model No. FFTR18G2Q

SP-32 & SP-32D SP-33, SP-33D SP-34, SP-34D. Description. Specifications. Single Stage Temperature Control

Installation Instructions Read these instructions completely before attempting to install the Vertical EconoMi$er X Accessory.

Digital Room Thermostats with Touch Screen LCD

CP-9301 CP Application. Features. Applicable Literature. Electronic Actuator Drives General Instructions

PGMD Series 10 SEER. International Comfort Products 651 Heil Quaker Avenue Lewisburg, Tn Part No

Digital Fan Coil Thermostats with 0(2)-10 VDC Fan Output

GPC13M R-410A, 13 SEER. Packaged Air Conditioner. 3, 4, & 5 Tons. Cooling Capacity: 36,000-56,000 BTU/h

OVEN PARTS For Model: KEMS378BBL3, KEMS378BWH3, KEMS378BAL3 (Black) (White) (Almond)

Remote Temperature Controllers. Quick Selection Guide

FFTR1814QB5A FFTR1814QS5A FFTR1814QW5A

MF4E MF4E

Metasys Zoning Package Installation

MODELS DSH/KSH/DSV/KSV R-410A LOW-AMBIENT KIT

REPLACEMENT PARTS MANUAL

EI28BS56IB0 EI28BS56IS0 EI28BS56IW0

MX4X-6XXX Series MX4X-7XXX Series. Selection Guide. Applications. DuraDrive Series Actuators and Accessories

OVEN PARTS For Models:KEBC277KBL0, KEBC277KWH0, KEBC277KBT0 (Black) (White) (Biscuit)

The IAQ50 Air Damper/Monitor Installation and Maintenance Manual

Eaton Electronic Proportional (EP) Control for Medium Duty Piston Pumps

Wiring Diagrams (Including Accessories) (50/60 Hz)

2SA13 60HZ P A C K A G E D E L E C T R I C / E L E C T R I C

Discharge Air Control

SECTION CONTROL VALVE ACTUATORS

Y20EBA Linkage Kit, M100 to Barber-Colman 1/2 to 1-1/4 Inch Valves

Transcription:

ICP INSTALLATION INSTRUCTIONS for NPECOMZR00A00 ICP's economizer is convertible-it will work in either a down discharge or horizontal discharge application. Read these instructions completely and carefully before beginning installation. For Down (for Horizontal Application go to page ) 1. Unpack top and bottom filter racks and filters. Remove the side panel from the HVAC unit, ILL 1. Discard panel. ILL. 1 Compressor Compartment. Install bottom rack. Slide rack over to right side (when facing coil) of HVAC unit. Set rack in front of coil and screw rack to coil frame through pre-punched hole. Maximum screw length 1/.. Install top rack. Slide rack over to right side of HVAC unit. Set rack in front of coil and screw rack to coil frame. Maximum screw length 1/. Blank-off should fit between top and bottom racks to the far left of HVAC unit. (If using 1 filters, spacer may need to be removed to position blank-off. Once blank-off is in position, re-install spacer.). If using wide filter, remove spacer from top and bottom filter racks. (ILL..) Blank-off Side Panel shipped with HVAC unit. Remove and discard. Rack Detail ILL. Top filter rack Evaporator Coil. To change filter: Open hinged door. Remove middle filter first. Slide remaining filters to middle of rack for removal. To install filters, reverse above operation. Spacer for 1 filter HVAC unit screws Bottom filter ILL. Bottom filter rack Screw Manufacturer reserves the right to discontinue, or change at any time, specifications, designs and prices without notice and without incurring obligations. Form No. 06-1P Copyright MicroMetl Corporation 00. All rights reserved.

Down ILL. Install additional screw through HVAC unit flange into replacement panel. 1 7 / 16 Replacement panel. Shipped with economizer Coil 9 / 16 Install / x 1/8 gasket along divider flange Divider Divider w/hvac unit Gasket Top View /8 Alignment flange holes Horizontal filter access door 7 / 16 Relief Blade Detail Damper actuator Add / x 1/8 gasket here MicroMetl economizer Install / x 1/8 gasket along economizer bottom flange cover panel 1/ flange. Install the replacement panel (shipped with the economizer) over the compressor compartment of the HVAC unit. Screw in place through the prepunched holes. 6. Slide the economizer into the return air chamber, ILL.. Slide the economizer as far to the left as possible. The economizer's right side will slightly overlap the bottom filter rack and divider, see details. Be sure economizer is flat. 7. Route the economizer wiring harness through the grommet in the economizer side and through the HVAC units provided hole located in the upper part of the HVAC unit divider. (Install provided grommet in divider hole of HVAC unit.) Follow the included harness routing diagram. (see page 9) 8. Install / x 1/8 gasket along economizers bottom flange. Install cover panel over the economizer. Slide panel underneath HVAC unit flange. Screw in place to the divider, in the HVAC unit, base and top. Also, align economizers /8 flange to the outside of 1/ flange as shown and secure economizer cover panel to economizer using provided pre-punched alignment holes with 1 long tek screw. 8 ½

9. Screw the rainhood to the economizer panel through prepunched holes. Caulk the mating flanges of the rainhood. The top flange of the hood slips underneath the HVAC unit flange. After adjusting the minimum position setting on the actuator, install the / 8 x 19 / 8 aluminum filter in the rain hood. 11. Remove the cover panel shipped over the horizontal return opening. Locate the filter access panel and door latch angle. Install door latch angle. Screw the hinge to the HVAC unit over the horizontal return opening. Adjust the closure handles for a tight seal. 1. Install the provided filter access sticker on the hinged door. Horizontal supply air cover panel. Shipped on HVAC unit. ILL. 7 Replacement panel SIDE VIEW Down ILL. 6 Filters Down Aluminum water entrainment filter *Barometric relief damper *Barometric damper relieves approximately % of total system air. Actual relief will vary depending on job site conditions. Door latch angle Filter access door - hinged Install filter access door sticker 1/16 Rainhood Aluminum Filter 1. Be sure the seams are all water tight. Seal as required. 1. Follow the wiring instructions enclosed. (see page 7, 8) TOP VIEW ILL. 8 Screw Filter Coil Unit panel Compressor Door latch angle DOOR LATCH ANGLE DETAIL Hinge Hood 0 Replacement Panel

Horizontal For Horizontal (for Down Application go to page 1) 1. Unpack top and bottom filter racks and filters. Remove the side panel from the HVAC unit, ILL. 1, discard the panel. Compressor Compartment. Install bottom rack. Slide rack over to right side (when facing coil) of HVAC unit. Set rack in front of coil and screw rack to coil frame through pre-punched hole. Maximum screw length 1/.. Install top rack. Slide rack over to right side of HVAC unit. Set rack in front of coil and screw rack to coil frame. Maximum screw length 1/. Blank-off should fit between top and bottom racks to the far left of HVAC unit. (If using 1 filters, spacer may need to be removed to position blank-off. Once blank-off is in position, re-install spacer.) Side Panel shipped with HVAC unit. Remove and discard. If using wide filter, remove spacer from top and bottom filter racks. (ILL..) Blank-off Top filter rack Evaporator Coil. To change filter: Remove horizontal filter access door on economizer cover panel. Remove middle filter first. Slide remaining filters to middle of rack for removal. To install filters, reverse above operation. HVAC unit screws Bottom filter Spacer for 1 filter Rack Detail ILL. ILL. Bottom filter rack Screw

ILL. 6 Horizontal Install provided grommet in HVAC unit divider. 1 7/16 Replacement panel Shipped with economizer Install additional screw through unit flange into replacement panel. 9 / 16 Divider w/hvac unit Install / x 1/8 gasket along HVAC divider flange. Alignment holes cover panel 7 / 16 Coil Divider Gasket Blank-off Detail blank-off Install / x 1/8 gasket along HVAC bottom Install / x /8 Gasketing, Sides. blank-off (see detail) Caulk these corners after economizer is installed Screw into base Remove molded gasket from economizer for horizontal application. 6. Install the replacement panel over the compressor compartment. Screw in place through the prepunched holes. 7. Install provided economizer blank-off to bottom of economizer. Screw in place through the prepunched holes. 8. Install the / x /8 gasketing on the bottom flanges of the economizer (shaded area), ILL. 6., (economizer is shown in rotated position.) 9. Rotate the economizer on its side as shown, ILL. 6. Slide the economizer into the cabinet and as far to the left as possible. The economizer will set against the left side of the HVAC unit. Caulk as required. 10. Install the economizer cover panel over the economizer. Slide panel underneath HVAC unit flange. Screw in place to the divider in the HVAC unit, base and top. 11. Align the economizer to the cover panel with 1 long tek screw using the provided pre-punched alignment holes. NOTE: The relief damper must be sealed shut for the horizontal discharge application. Horizontal filter access door

Horizontal HVAC Unit ILL. 7 Replacement panel shipped with economizer Filter access door for horizontal application Install filter access door sticker. 1/16 Rainhood with water entrainment filter 11. Route the economizer wiring harness through the grommet in the economizer side and through the HVAC unit's provided hole located in the upper part of the HVAC unit divider. (Intall provided grommet in divider hole.) Follow the harness routing diagram. (see page 9) The side hinged panel and horizontal cover panel will not be used in the horizontal application. 1 1 / 8 1. Screw the rainhood to the economizer panel through the prepunched holes. Caulk the mating flanges of the rainhood. The top flange of the hood slips underneath the HVAC unit flange. An extended socket will be required for the left side of the hood. After adjusting the minimum position setting on the actuator, install the aluminum filter in the rainhood. Install the provided filter access sticker on the horizontal filter door. 1. Follow the wiring instructions, see page 7,8. 16 ILL. 8 6

Wiring Diagram for s (not Heat Pump) - NPECOMZR00A00 & NPECOMZR00A00 L1 L Equipment Transformer Yellow Brown Green White Main V Splice Box Yel. Brn. Grn. Resistor 9 Sensor TR S O S R 1 ACTUATOR TR1 + + 8 resistor 7 1K K 6 1S Gray Gray 1S1 TR VAC TR1 T T1 Sensor Orange Green s + Dry Bulb outside air sensor (or optional enthalpy) 7 Red Blue T P T1 P1 Min. Pos P1 P Minimum Position NOTES: Red 1 WIRING LEGEND 1 6 7 8 9 OPTIONAL LOW AMBIENT CONTROL TRANSFORMER IN HVAC UNIT. POWER SUPPLY. DISCONNECT MEANS AND OVERLOAD PROTECTION AS REQUIRED. MUST BE INSTALLED ON SUPPLY AIR FAN. 000 OHM AT C, 77 F REMOVE JUMPER WHEN OPTIONAL REMOTE POTENTIOMETER IS USED 1S IS AN ELECTRONIC SWITCH WHICH CLOSES WHEN POWERED BY A VAC INPUT. RELAY 1K & K ACTUATE WHEN THE OUTSIDE AIR SENSED BY THE ENTHALPY OR DRY BULB IS LOWER THAN THE SET POINT A-D. FACTORY INSTALLED 60 OHM, 1 WATT, % RESISTOR SHOULD BE REMOVED ONLY IF A SENSOR IS ADDED TO SR AND + FOR DIFFERENTIAL CHANGEOVER. RESISTER ONLY REQUIRED FOR FIXED DRY BULB. R W1 G Y1 Y - STAGE THERMOSTAT Optional Remote Potentiometer L Terminals Wire nut of equivalent connection MMC wiring harness Field supplied low voltage wire Field supplied high voltage wire Other low voltage wire CAUTION 1. Disconnect power supply before connecting writing to prevent electrical shock or equipment damage Form No. 87-6PW

Minimum Position Wiring Diagram For s with Heat Pump L1 L Equipment Transformer YELLOW ORANGE BROWN GREEN WHITE Main V Splice Box YEL. R1 N.O. 11 R1 11 resistor 9 RED Sensor TR S O + 8 resistor S R 1 TR1 + ACTUATOR 7 1K K 60 6 1S 1S1 Gray Gray TR VAC TR1 T T1 Orange Green Sensor s + Dry Bulb Outside Air Sensor (or optional enthalpy) 8 VOILET BLUE T P T1 P1 Min. Pos P1 P 1 6 7 8 9 11 NOTES: RED OPTIONAL LOW AMBIENT CONTROL. EQUIPMENT TRANSFORMER MUST BE SIZED TO ACCOMMO- DATE AN ADDITIONAL 1VA. IF NOT, AN ADDITIONAL OPTIONAL TRANSFORMER IS REQUIRED. POWER SUPPLY. DISCONNECT MEANS AND OVERLOAD PROTECTION AS REQUIRED. MUST BE INSTALLED IN SUPPLY AIR STREAM. 000 OHMS AT ºC, 77ºF REMOVE JUMPER WHEN OPTIONAL REMOTE POTENTIOM- ETER IS USED 1S IS AN ELECTRONIC SWITCH WHICH CLOSES WHEN POWERED BY A VAC INPUT. RELAY 1K & K ACTUATE WHEN THE OUTSIDE AIR SENSED BY THE ENTHALPY OR DRY BULB IS LOWER THAN THE SET POINT A-D. FACTORY INSTALLED 60 OHM, 1 WATT, % RESISTOR SHOULD BE REMOVED ONLY IF AN ENTHALPY OR ADJUST- ABLE DRY BULB SENSOR IS ADDED TO SR AND + FOR DIFFERENTIAL. RESISTOR ONLY REQUIRED FOR FIXED DRY BULB. R1- RELAY IS FIELD SUPPLIED AND FIELD INSTALLED. MOUNT RELAY IN CONTROL BOX, ABOVE INDOOR FAN RELAY. R1 1 11 R W W1 G O Y1 THERMOSTAT Y Optional Remote Potentiometer CAUTION 1. Disconnect power supply before connecting wiring to prevent electrical shock or equipment damage L WIRING LEGEND Terminals Wire nut or equivalent connection MMC wiring harness Field supplied low voltage wire Field supplied high voltage wire Other low voltage wire Form No. 87-6PW

Routing Wiring Harness Filter Damper actuator Damper logic module rainhood rainhood Damper actuator and dry bulb or enthalpy A ECONOMIZER CONTROLS INSTALLATION A Compressor Supply fan Dry bulb or enthalpy (optional) Water entrainment filter in hood harness from actuator Supply fan A-A Side View START-UP INSTRUCTIONS 1. After unit is wired begin start-up procedures.. Set thermostat functions to OFF. Set comfort levels to minimum cool and minimum heat.. Turn unit power on following manufacturer's start up instructions.. Turn thermostat fan function to ON. Unit indoor blower should start and damper motor will drive to minimum vent position. Minimum vent position should be adjusted on the economizer logic for the proper percentage of outdoor air.. Switch the thermostat function from OFF to HEAT or AUTO. Bring the comfort setpoint for heat up to engage first stage heating. Follow manufacturer s procedures to check heating cycle. Bring the comfort setpoint for heat up to engage second stage heating if available. Check this heating cycle also. 6. Under no circumstance should the economizer operate in a heating mode except for minium vent position. Main V splice box sensor. Field install. Coil 9 Top View Wiring harness. Factory attached to economizer actuator. Factory run to splice box. Replacement panel shipped with economizer Main V splice box harness sensor. Field install. ACCESSORY SLIDE-IN ECONOMIZER CONTROL INSTALLATION. 1. Unpackage economizer.. Install accessory in unit per installation instructions provided.. Remove parts bag and instructions from inside of accessory.. Install the discharge sensor in the supply fan section. The sensor must protrude into the supply air stream. It should not interfere with blower, etc.. Uncoil the wiring harness. Connect the two gray wires of the harness to the discharge sensor leads using the two wire nuts provided. 6. Route the remainder of the wire harness through the unit to the main V splice box. 7. Mount thermostat downstairs per the manufacturer s instructions. Run proper wire from the thermostat to the unit control panel. 8. Review the wiring diagram from this booklet. Connect unit, wire from the thermostat and harness from the economizer, together to match the diagram. 9. Follow start-up instructions below. 10. Adjust change over setpoint on logic module. 11. Adjust minimum position set point on logic module. 7. Change the thermostat function from HEAT to COOL or leave in AUTO. Drop the comfort setpoint down to engage first stage call for cooling. The first stage cooling call travels to the economizer. If the outdoor air is above the A through D setpoint, (see chart on next page), the first stage mechanical cooling is brought on. As the comfort setpoint is reduced more there will be a second call for cooling which will bring on second stage mechanical cooling if available. 8. In the cooling mode if the outdoor air is below the setpoint, the first stage call for cooling will open the economizer. As the comfort setpoint is reduced more there will be a second call for cooling. This call will bring on the first stage mechanical cooling to back up the economizer. 9. Once all stages have been cycled, and all adjustments made return thermostat to its proper operating mode, replace all doors, panels and hoods. 10. Leave a copy of these instructions with the customer.

System Description These instructions are for fully modulating electronically controlled economizers utilizing solid state logic throughout. A standard single or (recommended) two stage thermostat is all that is needed to complete the control and economizer system for the HVAC equipment. 1 6 8 10 7 9 Component Description 1. Damper actuator... 9901-008 provides v modulating control of economizer dampers, in. lb. of torque. (Honeywell M71A-1006). Ball joint for linkage connection.. sensor... 9901-0001 provides a signal (000 Ohms at C or 77 F) to the actuator during free cooling or economizer mode. The signal opens the economizer damper until the discharge temperature drops below. At this time the signal causes the motor to modulate the damper and mix outside air with return air to maintain a 0 F. to 6 F. discharge temperature.. Wire nuts to connect discharge sensor to the harness. 6. Dry bulb...9901-018 senses temperature of outside air and provides signal to the economizer logic. Opens outside air at 60, closes outside air at 70 (enthalpy optional). 7. /8 grommet fits /8 hole that wires may pass through to keep from chaffing. 8. Wire clamps to secure wires to base, dividers, etc.. 9. Wire harness color coded and pre-wired to actuator and economizer logic... 996-0087. 10. 1/ hex head screws to secure wire clamps.. logic... 9901-0017 accepts input from discharge sensor and outside air sensor. Analyzes input to control actuator modulation and economizer switching. Logic also houses minimum position adjustment and enthalpy or adjustable dry bulb adjustment. When used with optional differential sensors in the return air, the logic is capable of selecting the most economical air available for cooling. (Honeywell W79A-1001) 10

INTEGRATED ECONOMIZERS The purpose of an economizer is to use outdoor air for cooling, whenever possible, to reduce compressor operation. The economizer system initially responds to a signal from the cooling thermostat and functions as a true first stage for cooling, while providing maximum fuel economy. The economizer is automatically locked out during the heating mode and holds the outdoor air damper at the minimum position settings. During the occupied period, on a call for cooling, when outdoor air temperature or enthalpy (optional) conditions are low, the economizer actuator will proportion to maintain between 0º F and 6º F at thermistor discharge sensor. If the mixed or discharge temperature is above 6º F, actuator will open to admit additional outdoor air until the temperature returns to the 0º to 6º F range. If the mixed or discharge air temperature is below 0º F, the actuator will proportion closed, shutting the outdoor air damper until the temperature returns to the 0º to 6º F range. During the occupied period, the actuator will not close past the minimum position. If the fully open actuator cannot satisfy the space demand, mechanical cooling is sequenced on. During the unoccupied period, the actuator will override minimum position setting and drive fully closed. On a loss of power, the actuator will spring return fully closed. When in heating operation, or when outdoor air temperature or enthalpy (optional) conditions are high, economizer operation is locked out, and actuator is held at minimum position. The staging relay is used when the first stage compressors must provide mechanical cooling when assisting the economizer. The staging relay can be omitted when the second stage compressors can be used to assist the economizer with mechanical cooling. 11

Minimum Position Adjustment The minimum position potentiometer keeps the outdoor air damper from closing completely during system operation to provide ventilation. 1. Make sure the factory installed jumper is in place across terminals P and P 1.. If remote control of dampers is desired, connect the remote potentiometer to P and P 1 and turn it fully clockwise before adjusting the minimum position.. Connect V AC to system and adjust the potentiometer on the face of the logic module with a screwdriver for desired minimum position. Enthalpy Changeover Setpoint (optional) Single enthalpy: The enthalpy changeover setpoints is set to return the outdoor air damper to minimum position when the enthalpy rises above its set point. The enthalpy setpoint scale markings, located on W79 are A,B,C,D as shown below. The factory-installed 60-ohm jumper must be in place across terminals + and S R unless using differential enthalpy. DETERMINE MAXIMUM RELATIVE HUMIDITY FOR ECONOMIZER CHANGOVER example D C B A EXAMPLE FOR DETERMINING ENTHALPY CONTROL SETTING (1008-0100) DETERMINE MAXIMUM DRY BULB TEMPERATURE FOR ECONOMIZER CHANGEOVER Differential Changeover Setting (optional) Differential enthalpy control (optional) utilizes two enthalpy sensors connected to one W79 Control. The enthalpy setpoint scale markings, located on the W79, are A,B,C,D. Turn the setpoint potentiometer fully clockwise past the D setting. The economizer will select the air with lower enthalpy for cooling; i.e., if outdoor air has lower enthalpy than return air, then the outdoor air damper will be opened to bring in outdoor air for free cooling. The differential enthalpy connects to S R and + on the W799 logic. Note: The C760A adjustable dry bulb can also be used for differential change over. Only the temperature of the outdoor air and return air will be compared and the best selected for free cooling. W79 Logic Module CAUTION Exercise care when adjusting the changeover set point and minimum position setting. EXCESSIVE FORCE MAY DAMAGE THE CONTROLS Enthalpy Changeover Set Point Minimum Damper Position Setting LED Lights up to indicate Outdoor Air is Suitable for Free Cooling Manufacturer reserves the right to discontinue, or change at any time, specifications, designs and prices without notice and without incurring obligations. Form No. 06-1P Copyright MicroMetl Corporation 00. All rights reserved. 1