IMPROVEMENT IN DOUBLY FED INDUCTON GENERATOR UNDER FAULT USING INDUCTOR

Similar documents
Simulation and Analysis of a DFIG Wind Energy Conversion System with Genetic Fuzzy Controller

APPLICATION OF STATCOM FOR STABILITY ENHANCEMENT OF FSIG BASED GRID CONNECTED WIND FARM

CHAPTER 5 FAULT AND HARMONIC ANALYSIS USING PV ARRAY BASED STATCOM

Wind Farm Evaluation and Control

Fuzzy based STATCOM Controller for Grid connected wind Farms with Fixed Speed Induction Generators

Journal of American Science 2015;11(11) Integration of wind Power Plant on Electrical grid based on PSS/E

FAULT ANALYSIS OF AN ISLANDED MICRO-GRID WITH DOUBLY FED INDUCTION GENERATOR BASED WIND TURBINE

Statcom Operation for Wind Power Generator with Improved Transient Stability

IJSER. 1. Introduction. 2. Power flow of Doubly fed Induction Generator (DFIG) K. Srinivasa Rao 1 G. Kamalaker 2

A Variable Speed Wind Generation System Based on Doubly Fed Induction Generator

Possibilities of Distributed Generation Simulations Using by MATLAB

(by authors Jouko Niiranen, Slavomir Seman, Jari-Pekka Matsinen, Reijo Virtanen, and Antti Vilhunen)

Design and Control of Lab-Scale Variable Speed Wind Turbine Simulator using DFIG. Seung-Ho Song, Ji-Hoon Im, Hyeong-Jin Choi, Tae-Hyeong Kim

Laboratory Tests, Modeling and the Study of a Small Doubly-Fed Induction Generator (DFIG) in Autonomous and Grid-Connected Scenarios

COMPARISON BETWEEN ISOLATED AND GRID CONNECTED DFIG WIND TURBINE

Matlab Modeling and Simulation of Grid Connected Wind Power Generation Using Doubly Fed Induction Generator

Effect of crowbar resistance on fault ride through capability of doubly fed induction generator

Design and Modelling of Induction Generator Wind power Systems by using MATLAB/SIMULINK

Study of DFIG based Wind Turbine for Reactive Power Generation Capability

CONTROL AND PERFORMANCE OF A DOUBLY-FED INDUCTION MACHINE FOR WIND TURBINE SYSTEMS

ENHANCEMENT OF ROTOR ANGLE STABILITY OF POWER SYSTEM BY CONTROLLING RSC OF DFIG

Faults Mitigation Control Design for Grid Integration of Offshore Wind Farms and Oil & Gas Installations Using VSC HVDC

Modeling of Active Crowbar Protection Scheme for Various Types of Fault in Wind Energy Conversion System using DFIG

A PERFORMANCE COMPARISION BETWEEN BRUSH AND BRUSHLESS DOUBLY FED ASYNCHRONOUS GENERATORS FOR WIND POWER SYSTEMS

Performance of Low Power Wind-Driven Wound Rotor Induction Generators using Matlab

Workshop on Grid Integration of Variable Renewable Energy: Part 1

Modeling Of DFIG and Improving the LVRT Capability Of System Using Crowbar And Battery Energy Storage System

Power System Stability Analysis on System Connected to Wind Power Generation with Solid State Fault Current Limiter

Comparative Analysis of Integrating WECS with PMSG and DFIG Models connected to Power Grid Pertaining to Different Faults

APPLICATION OF VARIABLE FREQUENCY TRANSFORMER (VFT) FOR INTEGRATION OF WIND ENERGY SYSTEM

Grid Connected DFIG With Efficient Rotor Power Flow Control Under Sub & Super Synchronous Modes of Operation

International Journal Of Global Innovations -Vol.2, Issue.I Paper Id: SP-V2-I1-048 ISSN Online:

Using energy storage for modeling a stand-alone wind turbine system

Modelling and Simulation of DFIG with Fault Rid Through Protection

Coordinated Control of DFIG under Grid Fault Condition in Wind Energy Conversion System

Neural network based control of Doubly Fed Induction Generator in wind power generation.

Enhancement of Power Quality in Transmission Line Using Flexible Ac Transmission System

EE 742 Chap. 7: Wind Power Generation. Y. Baghzouz Fall 2011

Facility Employing Standard Converters for Testing DFIG Wind Generators up to 30kW

Stability Enhancement of DFIG Fed Wind Energy Conversion System Using Crowbar Protection Scheme

Critical Clearing Time and Voltage Stability of DG Integration in Lebanon: A Simulation Using MATLAB/SIMULINK

ASSESSING BEHAVOIR OF THE OUTER CROWBAR PROTECTION WITH THE DFIG DURING GRID FAULT

Dynamic Modeling of Doubly Fed Induction Generator Wind Turbines

DFIG Wind Turbine Modeling

Doubly fed electric machine

Analysis of Low Voltage Ride through Capability of FSIG Based Wind Farm Using STATCOM

Dynamic Performance Of DFIG Based WECS Under Different Voltage Sag

Performance Analysis of SCIG Coupled With Wind Turbine with and Without Fault Using RLC Load

Modelling and Simulation of DFIG based wind energy system

Control of Grid Voltage and Power of Doubly Fed Induction Generator wind turbines during grid faults

Fault Rid Through Protection of DFIG Based Wind Generation System

Development and Analysis of Bidirectional Converter for Electric Vehicle Application

6545(Print), ISSN (Online) Volume 4, Issue 2, March April (2013), IAEME & TECHNOLOGY (IJEET)

STUDY ON MAXIMUM POWER EXTRACTION CONTROL FOR PMSG BASED WIND ENERGY CONVERSION SYSTEM

Performance Analysis of Transmission Line system under Unsymmetrical Faults with UPFC

Design of Four Input Buck-Boost DC-DC Converter for Renewable Energy Application

Simulation Modeling and Control of Hybrid Ac/Dc Microgrid

Effect of prime mover speed on power factor of Grid Connected low capacity Induction Generator (GCIG)

LVRT of DFIG Wind Turbines - Crowbar vs. Stator Current Feedback Solution -

Low-Voltage Ride-Through Capability Improvement of DFIG-Based Wind Turbines

Real And Reactive Power Saving In Three Phase Induction Machine Using Star-Delta Switching Schemes

DYNAMIC BEHAVIOUR OF DFIG-BASED WIND TURBINES DURING SYMMETRICAL VOLTAGE DIPS

Co-Ordination Control and Analysis of Wind/Fuel Cell based Hybrid Micro-Grid using MATLAB/Simulink in Grid Connected Mode

Model Predictive Control of Back-to-Back Converter in PMSG Based Wind Energy System

Research on Transient Stability of Large Scale Onshore Wind Power Transmission via LCC HVDC

International Journal of Advanced Research in Electrical, Electronics and Instrumentation Engineering. (An ISO 3297: 2007 Certified Organization)

ENHANCEMENT OF TRANSIENT STABILITY OF SMART GRID

Combined Input Voltage and Slip Power Control of low power Wind-Driven WoundRotor Induction Generators

Grid Code Testing of Wind Turbines by VSC-based Test Equipment

FAULT ANALYSIS FOR VOLTAGE SOURCE INVERTER DRIVEN INDUCTION MOTOR DRIVE

MODELLING, SIMULATION AND ANALYSIS OF DOUBLY FED INDUCTION GENERATOR FOR WIND TURBINES

Studies regarding the modeling of a wind turbine with energy storage

PERFORMANCE ANALYSIS OF SQUIRREL CAGE INDUCTION GENERATOR USING STATCOM

Wind Power Plants with VSC Based STATCOM in PSCAD/EMTDC Environment

Asian Journal on Energy and Environment ISSN Available online at

IJREE - International Journal of Research in Electrical Engineering ISSN:

Anupam *1, Prof. S.U Kulkarni 2 1 ABSTRACT I. INTRODUCTION II. MODELLING OF WIND SPEED

EE 742 Chap. 7: Wind Power Generation. Y. Baghzouz

A Novel Technique for Energy & Cost Effective Drives for AC & DC Motors

Experience on Technical Solutions for Grid Integration of Offshore Windfarms

DESIGN AND ANALYSIS OF CONVERTER FED BRUSHLESS DC (BLDC) MOTOR

Simulation of real and reactive power flow Assessment with UPFC connected to a Single/double transmission line

DIRECT TORQUE CONTROL FOR DOUBLY- FED INDUCTION MACHINE BASED WIND TURBINES

LOAD SHARING WITH PARALLEL INVERTERS FOR INDUCTION MOTOR DRIVE APPLICATION

Dynamic Behaviour of Asynchronous Generator In Stand-Alone Mode Under Load Perturbation Using MATLAB/SIMULINK

Published by: PIONEER RESEARCH & DEVELOPMENT GROUP ( 201

New York Science Journal 2017;10(3)

A Comprehensive Study on Speed Control of DC Motor with Field and Armature Control R.Soundara Rajan Dy. General Manager, Bharat Dynamics Limited

Simulated Switching Transients in the External Grid of Walney Offshore Wind Farm

Implementation of draft IEC Generic Model of Type 1 Wind Turbine Generator in PowerFactory and Simulink

Mathematical Modeling of DFIG for Reactive Power Loss Analysis and Controlling

Control Strategy for DFIG Wind Turbine to Enhance LVRT under Various Faults

Battery Energy Storage System addressing the Power Quality Issue in Grid Connected Wind Energy Conversion System 9/15/2017 1

Design and Simulation of Wind Energy Conversion System Synchronized with Electrical Grid Using DFIG

Transient Stability Analysis of Power System with Wind Generators

DUAL BRIDGE RECTIFIER FOR PMSG VARIABLE SPEED WIND ENERGY CONVERSION SYSTEMS

Controlling Of DFIG Wind Turbine Under Unbalanced Grid Fault Condition

Published in: Proceedings of the International Conference and Exhibition of Renewable Energy 2008 (RE2008)

PERFORMANCE AND ENHANCEMENT OF Z-SOURCE INVERTER FED BLDC MOTOR USING SLIDING MODE OBSERVER

Maximum Power Point Tracking in DFIG based Wind Energy Conversion System using HCS Algorithm

Transcription:

IMPROVEMENT IN DOUBLY FED INDUCTON GENERATOR UNDER FAULT USING INDUCTOR Uttam Kumar 1, Sandeep Kumar Pal 2, Harshit Kumar Yagyasaini 3, Bharat 4, Siddharth Jain 5 1, 2,3,4 Students, Electrical Engineering Department Greater Noida Institutes of Technology, Gr.Noida, (India) 5 Assistant Professor, Electrical Engineering Department Greater Noida Institutes of Technology, Gr. Noida, (India) ABSTRACT This project concentrates on the Low Voltage Ride Through (LVRT) capability of Doubly Fed Induction Generator (DFIG) wind turbine. The main attention in the project is, to the ability to protect itself without disconnection during grid faults, when the fault occurs the line voltage or current becomes 8 times to the normal rating, which can damage the converter which are connected to the rotor side. For this we are using an inductor for the protection of over voltage and currents, which is carried out in Matlab/Simulink, which reduces the over voltage and current during fault. 3-phase inductance is connected in series with the stator terminals. Keywords: DFIG, Grid Stability, Wind Turbine Technology. I.INTRODUCTON As wind power begins to represent a greater proportion of total generation capacity, wind farms are having greater influence over power system behaviour. In this scenario, wind farms are required to contribute to the stability of the system, including the key issue of fault-ride-through (FRT), which refers to the capability of generation plant to remain connected, dynamically stable, and offer network support throughout a serious voltage disturbance on the transmission network. Although the voltage dips associated with grid faults may last for only a few cycles, they can bring about certain undesirable characteristics of induction-machine generators In the past, wind turbine generators were disconnected fromthe system during faults. Nowadays, there is an increasingrequirement for wind farms to remain connected to the powersystem during faults, since the wind power lost might affect the system stability Therefore, the wind turbine behaviour during system performance and its influence in the system protection must be analyzed. One of the most frequent irrelevant features about integratingwind energy into the electricity network is that it is treated inisolation. An electricity system in practice is modify like amassive bath tub, with hundreds of taps providing the input and millions of plug holes draining the output. The taps and plugs are opening and closing at all the time. For the grid operators, the task is to make sure there is enough water in the tub to maintain system security. It is therefore the combined effects of all technologies, as well as the demand patterns, that matters. The specific nature of wind power as a distributed and variable generation source requires specific infrastructure investments and the implementation of new technology and grid management concepts. High levels of wind energy in system can impact on grid stability, congestion management and transmission efficiency and 20 P a g e

transmission adequacy. A grid code covers all material technical aspects relating to connections to, and the operation and use of, a country s electricity transmission system. They lay down rules which define the ways in which generating stations connecting to the system must operate in order to maintain grid stability. II. DOUBLY-FED INDUCTION GENERATOR The wind turbine and the doubly-fed induction generator(wtdfig) are shown in the figure\. The AC/DC/AC converter is divided into two components shown as rotor-side converter (Crotor) and grid-side converter (Cgrid). Crotor and Cgrid are Voltage-Sourced Converters that use forced commutated power electronic devices (IGBTs) to synthesize an AC voltage from a DC voltage source. A capacitor connected on the DC side acts as the DC voltage source. A coupling inductor L is used to connect Cgrid to the grid. The three-phase rotor winding is connected to Crotor by slip rings and brushes and the three-phase stator winding is directly connected to the grid. The power captured by the wind turbine is converted into electrical power by the induction generator and it is transmitted to the grid by the stator and the rotor windings. Figure 1. Operating Principle of the Wind Turbine Doubly-Fed Induction Generator III.INDUCTANCES FOR REDUCING TRANSIENTS A 3-phase inductance, equal to magnitude of DFIG self inductance, is inserted at stator terminals for a time equivalent to time taken to reach steady state. It is then disconnected using a timer switch, since its pertinent existence affects the generator performance. The effect of inserting these inductances is investigated at sharp wind speed variation. Connecting inductances to stator terminals where the stator self inductance Ls is replaced by Ls + L ext., where L ext is the proposed added external inductance. The applied external inductances, reduced the stator and rotor currents and voltage to nearly steady state value, as shown in Figs. 3 and 4 and not only improvement in transient of stator and rotor current but along with this we got an improved power factor at the time of simulation of the system power factor is improved as shown in Fig. 5 (steady state p.f. value = 0.92), when compared to Fig.2, which demonstrates the system power factor without inductances(steady state p.f. value = 0.575). 21 P a g e

Figure. 2. System power factor. Figure. 3. Stator current at abrupt wind speed variation with inductances. Figure.4. Rotor current at abrupt wind speed variation with inductances Figure. 5. System p.f. with Inductances. 22 P a g e

IV.EXPERIMENTAL SETUP The 9MW wind farm is connected to a 25 kv network, via a 66 KV/440V transformer. The transformer is rated 12 MV A. A resistive load of 500kw is connected at the wind farm. A high pass capacitor filter is used, the DFIG wind farm is connected to the 120 kv network through a 30 km 66 kv line and a 120/125 kv transformer. V.CONCLUSION The series reactor protects the flow of high rotor current and stator current both in grid and wind farm itself. During fault the impedance of the grid and wind farm becomes very low by inserting series reactor in the grid side converter it lowers the value of fault current in grid and wind farm. REFERANCE [I] J B. Ekanayake, L. Holdsworth, X G. Wu, N. Jenkins, "Dynamic Modeling of Doubly Fed Induction Generator Wind Turbines," IEEETransaction on Power Systems, Vol. 18.No. 2, May 2003, pp. 803-809. [2] J G. Slootweg, H. Polinder, W L.Kling, "Dynamic Modeling of a Wind Turbine with Doubly Fed Induction Generator " Proc. of 2001 IEEE Power Engineering Society Summer Meeting, Vol. I, pp. 644-649. [3] L. Holdsworth, X G. Wu; 1. B. Ekanayake, N. Jenkins: "Comparison of fixed speed and doubly-fed induction wind turbines during power system disturbances" lee Proceedings - Generation, Transmission and Distribution, Volume: ISO, Issue: 3, 13 May 2003, pp. 343-352. [4] A Tapia, G. Tapia, J.X Ostolaza, J. R. Saenz: "Modeling and control of a wind turbine driven doubly fed induction generator" IEEE Transactions on Energy Conversion, Volume: 18, Issue: 2, June 2003, pp. 194-204. [5] R. Koessler, S Pillutla, L. Trinh, D. Dickmander: "Integration of large wind farms into utility grids (Part I - Modeling of DFlG)", Proc. Of 2003 IEEE PES General Meeting. [6] M. H. J Bollen, M. Martins, G. Olguin, "Voltage dips at the terminals of wind-power installations," presented at the Nordic Wind Power Conference 2004, 1-2 March 2004, Chalmers University of Technology, Goteborg, Sweden. [7] F. Runcos, R. Carlson, A M. Oliveira, P Kuo-Peng, N. Sadowski, "Performance Analysis of a Brushless Double Fed Cage Induction Generator," presented at the Nordic Wind Power Conference 2004, 1-2 March 2004, Chalmers University of Technology, GOteborg, Sweden. [8] J Niiranen, "Voltage Dip Ride Through of Doubly-fed Generator Equipped with Active Crowbar, " presented at the Nordic Wind Power Conference 2004, 1-2 March 2004, Chalmers University of Technology, Goteborg, Sweden. [9] MATLAB Sim Power Systems User's Guide, Version 4.6 (R2008a), http://www.mathworks.com/access/helpdesk/help/toolbox/physmod/powersysl [10] Akhmatov V., "Induction Generators for Wind Power", Multi-Science Publishing Company, Ltd., 2005. [11] EOLE Program 2010, ''http://www.edfcom'',2010. 23 P a g e

[12] 0 Aluko, T.M Smith,L.M Tolbert, "Behavior of DFIG Under Nearby Wind Plant Fault", IEEE Publishing Company, Ltd., 20 10. [13] Ling PENG "Reconfiguration du dispositif de commanded' uneeolienneen cas de creux de tension" These SoutenueIe 17/06/ 2010 L2EP LlLLE. 24 P a g e