Automatic shut-off valves are necessary in combustion systems to provide reliable, positive shut off of fuels.

Locktite Manual Reset Gas Shut-Off Valves

VOG Series VOG15.01xU1 Oil Safety Shut-off Valves with Proof of Closure (POC)

Field proven low emissions. State-of-the-art low NOx firing - adjustable for application flexibility

Features 1. Differential Latch-type, lightweight, dependable

Type HSR Pressure Reducing Regulator for Residential, Commercial or Industrial Applications

Engineering Information. Solenoid Valves Principles of Operation. Solenoid Valves. Direct Acting Valves (Figures 1A, 1B)

Model DDX Deluge Valves 4" (100 mm), 6" (150 mm) and 165 mm Sizes

Model DDX Deluge Valve 8 (200mm) Features

Design and Application Details

Series 8000 Air Actuated Valves

Design and Application Details MICRO-RATIO Valves

Type HSR Pressure Reducing Regulator for Residential, Commercial, or Industrial Applications

Installation Instructions

cs200 series commercial / Industrial pressure reducing regulators

Technical Principles of Valves

North American Y-Type Strainers for Gas, Oil, Oxygen, Steam

T205 Series Tank Blanketing Regulators

VA, VF, and VS Series Direct Mounted Globe Valve Assemblies. Application. Features

Instructions for Installation, Operation, Care and Maintenance

T205 Series Tank Blanketing Regulators

EMERGENCY SHUTOFF AND FIRESAFE VALVES FIGURE 1075

VB-9323 Series. Application. Features. Applicable Literature. 2-1/2" to 6" 125 Lb. Flanged Three-Way Diverting Valves General Instructions

P99 Pressure Reducing Regulator

Deep Well Pump Control Valve

Adjustable Port Valves for HOT or COLD AIR, GAS, OIL, WATER, STEAM

Variable Area Flowmeter BROCHURE

TECHNICAL DATA. Q= C v P S

TECHNICAL DATA. Q= C v P Cv = Flow Factor (GPM/1 PSI P)

627 Series Pressure Reducing Regulators

Valve model number description

Types 1808 and 1808A Pilot-Operated Relief Valves or Backpressure Regulators

Solenoid Valves. Options/Accessories - ASCO offers a wide variety of accessories and optional features to meet your specific application requirements.

LVG SERIES. Gas Limiting Orifice Valve. Features. Benefits. Combustion Excellence Since 1888 LVG-1

VGD Series VGDxx.xxxU Gas Valves for use with SKPxx.xxxU electro hydraulic actuators

627 Series Pressure Reducing Regulators

FD68 BURNERS SELECTION GUIDE & ENGINEERING SPECS

KINEMAX. Medium velocity gas or oil burners

Q= C. v P S Refer to Table 1 for part numbers and shipping weights. Accessories: Table 1: Valve Part Numbers and Specifications

CP400 Series Commercial/Industrial Pressure Loaded Pressure Reducing Regulators

15100 VALVES. E. Section Building Automation and Control System Guidelines

SKP Series SKP25 U.. Pressure Regulating Gas Valve Actuator with Safety Shut-off Function

MULTIFIRE. High temperature dual fuel burner

Valve Selection. 1. Function and service considerations

Installation, Operation and Maintenance Manual

CS800 Series Commercial/Industrial Pressure Reducing Regulators

1470 SERIES HOT AIR GAS BURNER

627 Series Pressure Reducing Regulators

BRASS BALL VALVES. CSA, UL, cul CGA 9.1 and FM Approved. Female NPT, Male NPT and Flare ends in various configurations from 3/8 to 1.0.

Design Standard. Purpose: Design Standard:

SECTION VALVES

Skotch Trifecta Oil Valve System

MOTOR SPEED PRODUCT LINE: CAST IRON PUMPS TABLE OF CONTENTS SERIES DESCRIPTION RELATED PRODUCTS OPERATING RANGE. Section 1442 Page 1442.

TECHNICAL DATA. Inlet Type Outlet Type OBSOLETE 6 (DN150)

The PL Series Pressure Air Release Valves. Sizes 1 thru 6 Available Compound Lever System Adjustable Buna-N Rubber Plunger. Crispin.

Instructions for Installation, Operation, Care and Maintenance

TECHNICAL DATA 1-1/2 (dn40)

SKP Series SKP15 U.. Gas Valve Actuator with Safety Shutoff Function

Python Series Control Valves

Features Globe Valve 2-Way & 3-Way Assembly Features:

LAR Training. Series 8000 Pneumatic Safety Shut Off Valves Mark Lampe May,

Natural Gas Reference Guide

High Pressure 2-way 2 1/2-6 Globe Valves

Refinery Supply Company, Inc.

1466 SERIES COLD AIR GAS/OIL BURNER

W4100, W4200 & W4300 Electric Pump

Product Information. Model: LNVG, LNVLG Burner Sizes: 13, 15, 17, 20, 21, 25 GENERAL DESCRIPTION U.L. STANDARD EQUIPMENT

M/MR Modulating Valves TABLE OF CONTENTS DESCRIPTION SPECIFICATIONS. For Atmospheric, Infrared, and Direct Fired Burners

Type T205B Balanced Tank Blanketing Regulator

M-50/55 Series. Fixed setting flow switch with in-line flow

METAL VAREA-METER STRAIGHT THROUGH TYPE ROTAMETER

SMARTLINK METER. Digital Self-checking Thermal Mass Flow Meter

VB VALVES & AUTOMATION

A. American National Standards Institute: 1. ANSI Z Relief Valves for Hot Water Supply Systems.

NE January 2016 SINGLE SEATED CAGE VALVES SERIES 9100 MODEL Previously manufactured by Dezurik and Honeywell

Check Valve AP64 P.149. Vacuum Generator Vacuum Generator Module Vacuum Generator Module AP7 & 70 AP71 AP72. Flow Switch Flow Switch (For high flow)

Type 310A-32A Pressure Reducing Regulator

SUBMITTAL DATA WATER PRESSURE BOOSTER SYSTEMS

3 Edition Product brochure GB AGA

Self-Operating Temperature Regulators

PGM Prepiped Gas Manifold

Electronic Control Valves

Tightness control TC. Product brochure GB Edition 12.10

T205VB Series Tank Blanketing Vacuum Breakers

WARNING. Diode Package The Murphy diode package ( ) is designed to allow the fuel shutoff valve to be used with dual Magneto Ignition systems.

Tuffy Liquid Level Switches

CAPSU-PHOTOHELIC PRESSURE SWITCH/GAGE*

SECTION FACILITY FUEL - NATURAL GAS PIPING AND SYSTEMS

TECHNICAL DATA. Viking Technical Data may be found on Style: 90 Degree Pattern (inlet to outlet)

VALVES. A. Section HVAC Basic Materials and Methods. E. Section Building Automation and Control System Guidelines

Eclipse Vortometric Burners Series HI

AF series contactors (9 2650)

ISO 9001 : Dual Plate Wafer Check Valves. API 594 Design API 598 Tested. Maximizing the Flow

Transcription:

Maxon Shut-Off and Vent Valves General Purpose Bulletin 60 " Series 808 position "TO" 2" Series 00-CP position L with stainless steel body " Series STO-ACP position R Electrically actuated valves shut off gas or oil lines reliably. Normally open versions available for vent or process purge lines with Maxon's longlasting metal-to-metal seating. Application flexibility provided with 3/8" through 6" diameter line sizes, C v flow factors up to 12, and line pressures up to 600 PSIG. All Maxon top assembly enclosures meet approval sanctions: NEMA 1, 3, 3S, 4, and 12; CSA 2, 4, and 5; Available with NEMA 4X trim (optional) CORPORATION 1 East 18th Street, P.O. Box 68, Muncie, Indiana, 477-0068. Phone: (765) 284-34. FAX: 765-286-8394

Page 62 Normally open or normally closed valves 4" Series 00-SCP position L 1.5" Series STO-M position L Sanctioned service valve approvals: FM (Factory Mutual) sanctioned UL (Underwriters Laboratories) sanctioned CGA (Canadian Gas Association) sanctioned IRI (Industrial Risk Insurers) approvable for block/bleed/vent systems Contact your Maxon sales representative for international sanctions information Handles flowing fluid temperatures: Rising stem bodies from - F (-28 C) to +1 F (+60 C) Swinging gate bodies from - F (-28 C) to +5 F (+288 C) Any ambient temperature from - F (-28 C) to +1 F (+60 C) 4" Series 00 position L Valve body connections designed to ANSI (American National Standards Institute) standards. ISO (International Standards Organization) standards also available. Various application requirements met with manual reset or automatic reset motorized operators. Minimize line pressure drops with straight-through flow swinging gate or rising stem (guillotine action) valve bodies

Page 63 Maxon Valves large or small, gas or oil, open or closed 1" Series 230 position "L" 1" Series 87 position "TO" 1" Series 760 position L Minimal field maintenance required. Positive visual indication of valve body position is provided by large two-color open-shut indicator. Bodies built for heavy duty industrial service of one-piece cast iron, cast steel or cast stainless steel. Installation piping convenience obtained from field rotatable top assemblies. Special operating features available in Packaged versions. Micro-lapped seating wears in, not out.

Page 64 Accessory Options 1" Series 250 position L with socket welded nipples & flanges 1.25" Series 808 position R, with wheel & chain assembly Positive indication of valve body position provided through: Auxiliary SPDT and DPDT signal switches mounted inside valve top enclosure. Proof-of-open and/or Proof-of-closed position switches. Built-in over travel valve body design meets requirements of insurance standards. External junction box requirement eliminated with built-in valve wiring compartment and electrical terminal block. Manual reset valves may be mounted in overhead lines with use of wheel and chain option. Companion flange sets available to simplify installation. 1/99 CORPORATION 1 East 18th Street, P.O. Box 68, Muncie, Indiana, 477-0068. Phone: (765) 284-34. FAX: 765-286-8394

Maxon Valves Page 65 Design Features and Operating Concepts Valves with electro-mechanical actuators for quick opening or closing action Normally closed shut-off valves are used in burner system fuel supply lines on industrial boilers, furnaces, ovens, kilns, and other heating processes. All valves are designed to shut-off fuel automatically and instantly with any interruption in the electric power supplied through your safety circuit. These valves are also used for the manual or motorized opening or closing of pipe lines carrying gases and liquids commonly used in industrial processes. Normally closed valves cannot be opened until the interlocking safety control circuit is proven and resulting electrical power is supplied to the shut-off valve. Motorized automatic valve actuators are used where remote access or unmanned applications are needed. NOTE: Valve motors are protected against thermal overload. Normal duty cycles of 1 cycle per minute or less should allow motor thermal overload to sufficiently cool between cycles. If the normal valve duty cycle is exceeded, the motor must be allowed to cool before the thermal protection will automatically reset. Normally open vent valves are most often used as the bleed valve in a block-and-bleed pipe train, sometimes required by insurance authorities. They are designed to open a vent line automatically and instantly upon any interruption in the electric power supply through your safety control circuit. These normally open valves are also used in protective atmosphere systems and other gaseous and fluid service requiring quick opening or by-pass purging action. Like the normally closed versions, both automatic and manual reset actuators are available for remote access locations, or when operating personnel's physical presence is preferred. All Maxon valves feature one-piece cast iron or cast steel bodies with micro-lapped seats and discs. Straight through flow path minimizes pressure drop through full open swinging gate or rising stem (guillotine action) bodies. Manual reset actuators require operating personnel to be physically present to actuate the valve from its at rest position. 1/99

Page 66 Maxon Valves Valve Design Details To provide seals in your process service lines, Maxon uses two different styles of valve bodies: Seat Valve Assembly Seat Normally-Closed Disc Normally-Open Disc Valve Assembly Disc Carrier Disc Rising stem (guillotine action) bodies are frequently used in normally closed and normally open gas valves. The microlapped, spring loaded guillotine disc gets a pressure assist from the flowing gases to seal against the downstream micro-lapped metal seat ring. The carefully machined seal surfaces and extremely close tolerances of the valve body operating mechanism promote positive closing action. Frequent cycling action constantly shears accumulated dirt or residue from the disc and seat to insure instantaneous and reliable sealing. The location of the port in the disc is the basic difference between normally open and normally closed valve bodies. Both valves function by the top assembly mechanism driving the stem and disc down into the valve body, opening (or closing) the flow path. Both valves trip to their rest position when their top assembly's compression spring is released to pull the stem and connected disc up out of the body. Swinging gate bodies are frequently used in normally closed oil valves and for some non-combustible gas applications. This design provides the same seal capabilities, but in a slightly different operating mode. The hard faced micro-lapped seat nut is threaded into the one-piece valve body. The free-floating, hard faced, spring loaded circular disc swings across the seat. Line pressure also assists in sealing the disc to the downstream seat. Here again, frequent use and cycling actually helps to keep your valve clean. Since the free-floating disc is swinging across the circular seat nut on the arc created by the disc carrier, the disc rotates slightly on every cycle. This provides a fresh, clean surface area for sealing off the flow lines. Maxon valve bodies have special service trim options available to meet your particular fluid service requirements. Contact your Maxon representative for details.

Maxon Valves Page 67 Valve Capacities/Specifications Table 1: Normally closed valve bodies Material Iron Cast Steel or Stainless Steel End Connections Threaded Flanged Threaded Flanged Pipe Size (in inches) Cv Factor Type [1]. 375 &.5 3. 4 SG.75 9.6 SG See catalog pages 6117-6119 for construction details. NOTE: Typically, pressure drop for gas flows should not exceed % of inlet pressure; however, for 2" and smaller valves, the drop should not exceed 5 PSIG, and for " and larger valves, must not exceed PSIG. Select valve size on basis of the lower of these parameters to avoid critical flow conditions. 1 1.25 12 SG 17 SG 45 1.5 53 3 127 4 173 423 127 4 3 423 4 6 490 719 869 1172. 5 3. 4 SG. 75 9. 6 SG 1 1.25 [1] = Rising Stem valve body SG = Swinging Gate valve body 12 SG 17 SG 45 SG 1.5 53 4 3 423 4 6 490 719 869 1172 Table 2: Normally open valve bodies Material Iron Cast Steel End Connections Threaded Flanged Threaded Flanged Pipe Size (in inches) Each complete valve assembly must include one of these valve bodies, regardless of ultimate series designation. Flows through the valve body and resulting pressure drops may be estimated by inserting your specific conditions into the following formula and using C v flow factors given for each valve body. Gases: Q = (1360) x (C v ) x (P 1 +P 2 ) x (P 1 P 2 ) G T f 2 Liquids: V = (C v ) x (P 1 P 2 ) Where: G = Gas specific gravity (air = 1.0) G f = Specific gravity @ flowing temperature F P 1 = Inlet pressure PSIA (14.7 psi + psi gauge) P 2 = Outlet pressure PSIA (14.7 psi + psi gauge) Q = Cubic feet per hour @ 14.7 PSIA and 60 F T f = Flowing temperature absolute (460 + F) V = Flow in U.S. gallons/minute of water G f Cv Factor Type [1]. 75 1 1.5 53 4 3 423 4 3 423 4 490 1 1.5 53 4 3 423 4 490 2/00

Page 68 Maxon Valves Valve Capacities with Natural Gas at 5 inches w.c. Inlet Pressure 000 00 6" HC 6" 4" HC 4" CP 3" CP " CP 3" " 2" 1.5" 1.25" 1172 Cv 869 Cv 719 Cv 490 Cv 423 Cv 4 Cv 173 Cv 127 Cv 86 Cv 53 Cv 45 Cv Cv Approximate pressure drops for various valve sizes and flows may be determined by using this graph. Typically, pressure drop for fuel flows should not exceed % of inlet pressure. Select valve size on basis of the lower of these parameters to avoid critical flow conditions. 0.75 " & 1" 0.2 0.3 0.4 0.5

Maxon Valves Page 69 Valve Capacities with Natural Gas at 1 PSIG Inlet Pressure Approximate pressure drops for various valve sizes and flows may be determined by using this graph. Typically, pressure drop for fuel flows should not exceed % of inlet pressure. Select valve size on basis of the lower of these parameters to avoid critical flow conditions. 0000 000 00 4" CP 3" CP " CP 3" " 2" 1.5" 1.25".75 " & 1" 719 Cv 490 Cv 423 Cv 4 Cv 6" HC 6" 869 Cv 4" HC 1172 Cv 173 Cv 127 Cv 86 Cv 53 Cv 45 Cv Cv 0 0.5 5 1/99

Page 61 Maxon Valves Valve Capacities with Natural Gas at 5 PSIG Inlet Pressure 0000 000 00 6" HC 6" 4" HC 4" CP 3" CP " CP 3" " 2" 1.5" 1.25".75" & 1" 1172 Cv 869 Cv 719 Cv 490 Cv 423 Cv 4 Cv 173 Cv 127 Cv 86 Cv 53 Cv 45 Cv Cv Approximate pressure drops for various valve sizes and flows may be determined by using this graph. Typically, pressure drop for fuel flows should not exceed % of inlet pressure; however, for 2" and smaller valves, the drop should not exceed 5 PSIG, and for 2-1/2" and larger size valves, must not exceed PSIG. Select valve size on basis of the lower of these parameters to avoid critical flow conditions. 0 0.5 5

Maxon Valves Page 6111 Valve Capacities with #2 Oil To select a valve for YOUR application, use either C v factor calculations, or this graph showing approximate pressure drop at various flows of #2 oil. Typically, pressure drop for fuel flows should not exceed % of inlet pressure. For preheated #5 or #6 oil, multiply the required flow rate in GPH by the factor given in the table at right, then select a valve based upon that equivalent flow of #2 oil and the allowable drop. Oil Grade #5 #6 F @ Inlet 125 160 1 1 180 2 2 Factor 1.43 1.11 2.86 2.00 1.25 1.11 1.05 For example: To size for 5 PSIG drop with a GPH flow of #6 oil preheated to 1 F, the multiplier is 2. Equivalent flow of #2 oil is then x 2, or 00 GPH. Chart shows that a 5 PSIG drop will require use of a valve body having a C v factor of at least 45. 1/99

Page 6112 Maxon Valves Selection Data Normally closed, swinging gate valves Series Designation Material> Top Assembly Function Sanctioned S ervice [1] Iron (Non-sanctioned) [2] Sanctioned S ervice [1] Manual Reset 7 790 7-S; 760 Automatic Reset 47; 87 4790; 8790 47-S 4760; 8760 Cast Steel (Non-sanctioned) [2] 790-S 33790; 230 4790-S; 8790-S 33479; 250 [ 1] S anctioned valves are sold for fuel oils and may carry one or more sanctions (UL, FM, CGA). They are IRI approvable for liquified petroleum gases, #1 and #2 fuel oils, kerosene, JP- 4 and preheated #4, #5 and #6 oils with maximum viscosity of 00 SSU. [ 2] Non-sanctioned valves do not carry blanket approval/listings, and the pressure limits shown apply only for selected special service applications. An analysis of your fluid will determine the actual rating, trim, and specifics for your application. Temperature Limits All of these valves can handle fluid temperatures from - F (-28 C) to +2 F (+121 C). The Series 300 valves are designed to handle higher fluid temperatures up to +4 F (+232 C) and even up to +5 F (+288 C) with addition (at extra charge) of special stem seals. Ambient temperature limits vary. Any valve on this page using DC voltage and all Series 80 valves can handle ambient temperatures from - F (-28 C) to +125 F (+52 C). The other valves on this page handle ambient temperatures from - F (-28 C) to +1 F (+60 C). Operation All of these electro-mechanical valves require a constant supply of electrical energy to their holding solenoids inside the top assembly actuators. Once the solenoid is energized, the manual reset valve may be opened manually, or the automatic reset valve will automatically open. Any interruption of the electrical power to either of these valves causes an immediate trip of the valve to its normally closed position. Features: Normally closed Electrically actuated Swinging gate body For shut-off service For liquid and noncombustible gas service 1" Series 760 Available Sizes and Pressure Ratings M aximum Inlet Pressure (PSIG) Pipe Size CV (inches) Flow Factor Iron Bodies Cast Steel Bodies Fuel Oils Special Service Fuel Oils.375 [1] 3.4.5 [1]. 75 [1] 9. 6 0 0 1 12 600 600 1.25 17 1.25 HC 45 0 0 1.5 123 0 0 2 218 0 0 [1] Available in 87, 8760 & 8790 Shaded areas indicate 0# raised face flanged bodies.

Maxon Valves Page 6113 Series Designation Material> Top Assembly Function Manual Reset Automatic Reset Sanctioned S ervice [1] Iron Selection Data Normally closed, rising stem valves (Non-sanctioned) [2] Sanctioned S ervice [1] Cast Steel (Non-sanctioned) [2] 808; 808-CP 818; 818-CP 808-S; 808-S-CP 818-S; 818-S-CP 00; 00-CP 00 ; -CP 00-S; 00-S-CP 00-S -S; -S-CP -S [ 1] Sanctioned valves may carry one or more sanctions (UL, FM, CGA) for air, natural and liquified petroleum gases. They are normally approvable for clean fuel gases. Additionally, series with internal trim -2 are sanctioned for #1 and #2 fuel oils (except Series 00 (-S) are not listed FM approved for #2 fuel oil). 'SG' valves are preferable for liquid service (see page 6112). [ 2] Non-sanctioned valves do not carry blanket sanctions, and the pressure limits shown apply only for selected special service applications. An analysis of your fluid will determine the actual rating, trim and specifics for your application. Temperature Limits All these valves can handle fluid temperatures from - F (-28 C) to +1 F (+60 C). Oil viscosity not to exceed 00 SSU. Ambient temperature limits vary. Any valve on this page using DC voltage and all Series 00 valves can handle ambient temperatures from - F (-28 C) to +125 F (+52 C). The other valves on this page handle ambient temperatures from - F (-28 C) to +1 F (+60 C). Operation All of these electro-mechanical valves require a constant supply of electrical energy to their holding device inside the top assembly actuators. (In Series 808 and 00 valves, the device is a solenoid and Series 00 valves use an electro-magnetic clutch.) Once that device is energized, the manual reset valve may be manually opened, or the automatic reset valve will automatically open. Any interruption of the electrical power to either of these valves causes an immediate trip of the valve to its normally closed position. Available Sizes and Pressure Ratings Pipe Size (inches) C Flow Facto V r Clean Gases Iron Bodies M aximum Inlet Pressure (psi) [3] Special Service Features: Normally closed Electrically actuated Rising stem body For shut-off service Clean Gases 4" Series 00 Cast Steel Bodies.75 125 1 125 125 1.25 45 0 1.5 53 127 CP 4 3 173 5 3 CP 423 4 CP 490 4 HC [4] 719 60 60 [5] 6 869 5 5 6 HC [4] 1172 [5] [3] Maximum operating pressure differential (MOPD) in psi must not exceed maximum inlet pressure shown. [4] Series 00 valves [5] Contact your Maxon representative for pressure ratings for 5-3 trim NOTE: Shaded areas indicate flanged valve bodies. All others are threaded. 2/00

Page 6114 Maxon Valves Selection Data Normally open, rising stem valves Series Designation Material> Top Assembly Function Manual Reset Sanctioned S ervice [1] STO-M Iron Sanctioned (Non-sanctioned) [2] S ervice [1] STO-M STO-MS Cast Steel (Non-sanctioned) [2] STO-MS Automatic STO-A STO-A STO-AS STO-AS Reset STO-A-CP STO-A-CP STO-AS-CP STO-AS-CP [ 1] Sanctioned valves may carry one or more sanctions (UL, FM, CGA) for air, natural or liquified petroleum gases. They are normally approvable for clean fuel gases. Additionally, series with internal trim -2 are sanctioned for #1 and #2 fuel oils. [ 2] Non-sanctioned valves do not carry blanket sanctions, and the pressure limits shown apply only for selected special service applications. An analysis of your fluid will determine the actual rating, trim and specifics for your application. Temperature Limits All these valves can handle fluid temperatures from - F (-28 C) to +1 F (+60 C). Oil viscosity not to exceed 00 SSU. Ambient temperature limits vary. Any valve on this page using DC voltage can handle ambient temperatures from - F (-28 C) to +125 F (+52 C). The other valves on this page can handle ambient temperatures from - F (-28 C) to +1 F (+60 C). Operation All of these electro-mechanical valves require a constant supply of electrical energy to their holding solenoids inside the top assembly actuators. Once the solenoid is energized, the manual reset valve may be manually closed, or the automatic reset valve will automatically close. Any interruption of the electrical power to either of these valves causes an immediate trip of the valve to its normally open position. Features: Normally open Electrically actuated Rising stem body For vent and by-pass service " Series STO-ACP Available Sizes and Pressure Ratings Pipe Size (inches) C Flow Facto V r Clean Gases Iron Bodies M aximum Inlet Pressure (psi) [3] Special Service Clean Gases Cast Steel Bodies.75 125 1 125 125 [4] 1.5 53 CP 4 3 CP 423 [4] [4] 4 CP 490 [3] Maximum operating pressure differential (MOPD) in psi must not exceed maximum inlet pressures shown. [4] Contact your Maxon representative for pressure ratings for 5-3 trim. N OTE: Shaded areas indicate flanged valve bodies. All others are threaded.