EWAD-CZ EWAD-CZ. Inverter driven air-cooled chiller. ESEER up to 5.4. Inverter driven single screw compressor. Multiple efficiency and sound versions

Similar documents
Air Conditioners Technical Data

Air Conditioning. Technical Data EEDEN RXZ-N

Air Conditioning. Technical Data EEDEN RXZ-N

Air Conditioners. Technical Data UATYQ-CY1

Product. ortfolio RESIDENTIAL & LIGHT COMMERCIAL

Air Conditioning. Technical Data. Wall mounted unit EEDEN FTX-GV

Air Conditioning. Technical Data. Wall mounted unit EEDEN FTXS-K

Split. Air Conditioning Technical Data FTXC-A > FTXC25AV1B > FTXC35AV1B > FTXC50AV1B > FTXC60AV1B

Air Conditioning. Technical Data EEDEN RXJ-L

UATYQ-ABAY1. Air Conditioning Technical Data > UATYQ20ABAY1 > UATYQ25ABAY1 > UATYQ30ABAY1 > UATYQ45ABAY1 > UATYQ50ABAY1 > UATYQ55ABAY1

your comfort. our world. Biddle air curtains For connection to Daikin Sky Air Systems

Air Conditioning Technical Data FXDQ-A3 > FXDQ15A3VEB > FXDQ20A3VEB > FXDQ25A3VEB > FXDQ32A3VEB > FXDQ40A3VEB > FXDQ50A3VEB > FXDQ63A3VEB

Air Conditioners. Technical Data. Individual branch selector for VRV heat recovery (Individual BS box) EEDEN BSVQ P8

Fan Coil Units. Technical Data. Conceiled ceiling unit ECDEN FWB-BT

Technical Data. Air Conditioners

EEDEN technical data. air conditioning systems FDQ-B8V3B9. Split Sky Air

LSE kw. Outdoor packaged unit. Air/water chillers and heat pumps LSE PLUS

CGAM. Air-cooled scroll chiller. Accessories. Customer benefits. Tracer CH530 Control. Main features. Energy saving options.

CXAM. Options. Accessories

McQuay International WMC New Water Cooled Chiller with oil free centrifugal compressors

Air-Cooled Screw Chillers RTAF kw. The best bundled in one. Our best.

Index Features and advantages... 3 General characteristics... 5 Nomenclature Technical specifications... 11

Flex Series. Modular Air-cooled Chillers and Heat Pumps Cooling Capacity kw Heating Capacity kw

Chillers. EWAD-C- 620~1860 kw. Air-cooled R-134a. » Wide capacity range (620 kw kw) » Multiple efficiency and sound versions

technical data air conditioning systems 600x600 4-Way Blow Ceiling Mounted Cassette FXZQ-M9V1B

Air-Cooled Screw Chillers RTAF kw. The best bundled in one. Our best.

LG HVAC SOLUTION. LG Electronics. Distributed by. Copyright 2017 LG Electronics. All rights reserved.

Air-Cooled Liquid Chiller with integrated hydraulic module

Chiller. AQL/AQH 40 to 75. Air Cooled Water Chillers Cooling Only and Heat Pump Engineering Data Manual to 77.2 kw to 75.

Resolair 64 and 68. Comfort air conditioning unit with highly efficient regenerative heat storage packages. AIR VOLUME FLOW: 3,900 23,100 m³/h

Chiller. VLC 524 to Air Cooled Condensing Units Engineering Data Manual. 154 to 347 kw

Applied Systems. Technical Data. Concealed ceiling unit EEDEN FWP-AT

Air Conditioning Technical Data RZQSG-L3/9V1

Emerging Oil Free Technologies. Ray Good Global Director of Application Engineering Danfoss Turbocor Compressors, Inc.

19,1 261,0 kw COOLING 23,7 333,0 kw HEATING

Ultima Compact Chiller Range kW

Compresseur scroll. Refrigerant R410A SYSAQUAC. Air Cooled Condensing Units Models 25 to to 136.0kW

New ECOi Electric 2 and 3 pipe VRF systems. 2006/7 Range. All round air conditioning by

Inverter air to water heat pumps

VHA. Air cooled chiller with

Commercial and Technical Data

Midea VRFs/ Midea V5X. Timothy Huang Senior Engineer

VLH 504 to Air-to-Water Reverse Cycle Heat Pumps. 126 to 294 kw. 133 to 307 kw

24% higher part-load efficiency saves running costs.

WQL/WQH/WQRC 524 to 1204

01 Overview 02 ecoo. 03 HybridChiller. 04 Re-cooler. 05 Circuit Separation. 06 Services. Contents 04/2018. Overview. 02 Cooling innovation

AQVSL/AQVSH STAR 85 to 140

Chiller. SWS/SWR 1602 to Water Cooled Chillers Cooling Only and Condenserless Versions Engineering Data Manual.

Air Cooled Water Chillers. CLS 182 to to 150 kw. Technical Brochure TM CLS-W.3GB Date : October 2004 Supersedes : TM CLS-W.2GB/07.

HPR. Heat recovery units. from 700 to m³/h R410A HIGH EFFICIENCY WITH ENTHALPY EXCHANGER AND BUILT-IN HEAT PUMP SYSTEM

Chiller. AQSL 2612 to Air Cooled Chillers With or without total heat recovery Engineering Data Manual. 602 to 908 kw

VLS (Cooling Only) VLH (Heat Pump Version) VLR (Total Heat Recovery Version)

RESIDENTIAL & LIGHT COMMERCIAL AIR CONDITIONERS 2015 / 2016 EVERY BUILDING MATTERS

Air/Water chillers for outdoor installation Screw compressors, shell and tube heat exchangers and axial fans Cooling capacity kW 1402/9603

kw. Kappa Rev. Air cooled modular screw chiller & heat pump. Bullet points. General. Configurations

Advanced efficiency, precision cooling Design an HVAC system like no other

kw. Kappa Rev. Air cooled modular screw chiller & heat pump. Bullet points. General. Configurations

Advanced efficiency, precision cooling Design an HVAC system like no other

PowerFlex 6000 Medium Voltage AC Drives

AQWL/AQWH/AQWR 1404 to 2406

Fan coil units. Why choose Daikin fan coil units? 540 Products overview 542. Options & accessories 560. Round flow cassette 544 FWC-BT/BF 544

Advanced efficiency, precision cooling Design an HVAC system like no other

T Series. The most reliable HVAC system for transit is now better than ever.

30XW- 30XWH. Water-Cooled Liquid Chillers. Nominal cooling capacity kw Nominal heating capacity kw. Features and advantages

Air Cooled Single Screw Chiller/ Heat Pump

Split-Sky Air FDYP-B7 Concealed Ceiling Unit

REFRIGERANT AIR DRYERS FX 1-22

Refrigerant air dryers FX 1-22

NEW TECHNOLOGY BY RON CONRY

Danfoss Turbocor compressors Making a world of difference

NECS-WQ. Climaveneta Technical Bulletin NECS_WQ_0152_1604_201006_GB. INTEGRA unit for 4-pipe systems, water source ,6-522 kw

30XW- 30XWH. Water-Cooled Liquid Chillers. Nominal cooling capacity kw Nominal heating capacity kw

TECS2. Climaveneta Technical Bulletin TECS2_0211_1154_201211_EN. High efficiency chiller, air source for outdoor installation kw

T Series. The most reliable HVAC system for transit is now better than ever.

FULL DC INVERTER SYSTEMS INDIVIDUAL AND MODULAR CONSTRUCTION FLEXIBLE COMBINATIONS AIR CONDITIONING COMMERCIAL AIR CONDITIONERS SDV4 2014

technical catalogue tetris KW Chiller and heat pumps air/water

HFC R407C HEAT PUMP COOL DIGITAL COMPRESSOR. HFC R134a R407C HEAT DIGITAL PUMP HFC R407C HEAT PUMP DIGITAL. HFC R134a R407C HEAT DIGITAL PUMP HFC

PREMIUM INVERTER DUCTED AIR CONDITIONING

ULTIMA U75 U HP OIL-FREE TWO-STAGE VARIABLE SPEED ROTARY SCREW COMPRESSOR. Ultima

30% energy savings with Danfoss inverter scrolls accelerate ROI.

Reversible air-to-water scroll heat pumps

SLH 1202 to Air-to-Water Reverse Cycle Heat Pumps. With Screw Compressors. 261 to 775 kw. 287 to 853 kw

Blue e+ chillers with the principle

PART 1 GENERAL. Pfannenberg Inc.

technical data air conditioning systems RXG-C Wall Mounted, Inverter Controlled Unit Split Sky Air

Air cooled chillers With axial fans and power ratings from 238 to 1600 kw with two-screw compressor

Air Cooled CAPACITY: TR CHILLER PRODUCT DATA BOOK

COMFORT FOR LIFE DUCTLESS WALL & FLOOR MOUNTED HIGH-EFFICIENCY HEAT PUMP 20 SEER UP TO 12.5 HSPF UP TO 13 EER INVERTER, VARIABLE-SPEED COMPRESSOR

Heating. Technical Data. Daikin Altherma low temperature split EEDEN ERLQ-CV3

AQVL (Cooling Only Version) AQVH (Heat Pump Version)

modular multi intelligent, environmental and versatile

III. Roof Mount AC Mobile Climate Control 19 MCC Reference Manual 2014

MGE TM Galaxy TM 7000 GFC

kW. Ultima Screw Chiller Range kW. > Ultima Screw Chiller Range. Includes Ultima FreeCool Chiller Range

SCROLL COMPRESSORS. SF 1-6 ( kw/2-7.5 hp) / SF ( kw/3-30 hp)

FOCS2-W/CA-E. Climaveneta Technical Bulletin FOCS2_W_CA_E_1301_4802_201001_GB. High effi ciency water-cooled chillers kw

30-450kW. Now Available. Ultima Compact Chiller Range kW. > Ultima Compact Chiller Range. Free-Cooling models up to 450kW.

Heat pumps for swimming pools

Reciprocating Compressors AIRBOX / AIRBOX CENTER

TEAL FCTM. Chiller with integrated Free Cooling system chillers and heat pumps, kw

Transcription:

EWAD-CZ Inverter driven air-cooled chiller ESEER up to 5.4 Inverter driven single screw compressor Multiple efficiency and sound versions Wide operating range (up to 50 C ambient temperature) Low starting current Cooling capacity from 640 to 1,800 kw www.daikin.eu EWAD-CZ

Minimum inrush current Maximum power factor EWAD-CZ provides minimum inrush current compared to traditional starting methods. The use of variable speed motors eliminates the fluctuations in the power supply line and reduces the stress on the electrical equipment. This allows the reduction in size (and costs!) of the protection devices to be installed on the power supply line. Unit Full Load Current (A) Soft Starter Y-D Starter Inverter EWAD-CZ units feature an amazing 0.97 displacement power factor at whatever chiller load and operating condition. This delivers minimum current absorption and consequently reduces the cost of the electrical installation. The EWAD-CZ unit does not require the installation of traditional capacitors for power factor correction thus avoiding potential penalties related to reactive power. Displacement power factor Traditional chiller Inverter Starting Time Motor load Increase cooling ouput without changing the existing power supply line! The EWAD-CZ s superior energy efficiency combined with the highest possible displacement power factor allows you to increase the installed cooling capacity (up to +50%) without modifying the existing power supply line. EXISTING UNIT Installations Ampere limit Installed cooling capacity POWER FACTOR 0.8 EFFICIENCY CLASS C Amp limit due to existing electrical installation Traditional Chiller EWAD-CZ +25% cooling capacity +50% cooling capacity POWER FACTOR 0.85 POWER FACTOR 0.97 EFFICIENCY CLASS EFFICIENCY CLASS INVERTER A A

ESEER up to 5.4 EER up to 3.0 Daikin Ewad-Cz highest efficiency at both full and part load The EWAD-CZ series offers the highest EER part load values in the HVAC air-cooled chiller market, up to 36 % better than for traditional technology. This allows a significant reduction in the system running costs in compliance with the most stringent requirements in terms of energy consumption and environmental regulations. These aspects, together with Sustainable Building Design, are becoming more and more crucial factors in the real estate market. The EWAD-CZ leads the industry in energy efficiency, quiet operation and responsible refrigerant management: ideal for building owners who want to pursue Leadership in Energy and Environmental Design (LEED ). Unit operating EER Daikin Inverter chiller Traditional Chiller % load-oat C The combination of the variable speed single screw compressor and chiller control logic allow automatic modulation of the fan speed to achieve the optimum head pressure set-point and consequencely the best global chiller energy performance at part load. Our resulting resulting ESEER values are 25% higher than for traditional screw units and reach the highest ESEER values for this technology. 12 db(a) noise reduction to meet the most stringent regulations -12 db(a) Traditional Chiller During the night, when the background noise is lower, the acoustical impact of a chiller becomes more critical for neighbours that want quiet. In these conditions the outdoor temperature is lower as well as the cooling load. Power db Daikin Inverter -12 db(a) The EWAD-CZ works in partial load regime and the inverter devices adjust the speed of compressors and fans supplying the required cooling output and providing better sound performance. % load-oat C * Based on EWAD830CZXS rated at 700 kw, with 12/7 C Evap. and 35 C OAT

From 100% load +50 C ambient continuous modulation to 8% load Saving FOOTPRINT & Installation Time The EWAD-CZ series are lighter and smaller than other air cooled chillers available in the market. Its compact footprint is ideal for replacement projects, allowing easy transportation and installation thus resulting in structural cost savings. Extremely Wide Range of Operation, with Outside Ambient TEMPERATURES up to 50 C The EWAD-CZ is equipped with a Daikin single-screw compressor and its condensing section is properly sized in order to achieve +50 C ambient temperature while still allowing stepless unloading down to 8% capacity. (Referred to as the three compressors model). Differing from other technologies available in the market (eg. centrifugals) with a single screw compressor, there is no inefficient ON/OFF operation at part loads. Thanks to this unique design, the EWAD-CZ unit features one of the widest working ranges in the market. Internet Explorer Google Chrome PID Controller with Optimized Daikin Software and Network Ready features The EWAD-CZ unit is equipped with on-board PID controller, with a standard user-friendly in-built display, or an optional graphical touch screen. The controller is ready to be integrated with a wide range of BMS through standard communication protocols. The controller s display allows viewing of the unit s operating status and its multi-button keypad and rolling wheel allows the operator easy access to the unit s main functions.

EWAD-CZ 1.000 kw unit 8.5 meters long 1.5 m less Typical competitor 1.000 kw unit 11 meters long Single-Screw Compressor: Daikin "in house" Technology The compressor, the heart of the chiller, is fully developed, manufactured and serviced by Daikin. The Daikin inverter-driven, single-screw compressor is the top of screw tecnology with its integrated oil separator, the best energy efficiency both at full and part loads and a proven reliability thanks to thousands of units running all around the world. Plug & Play Unit Concept The EWAD-CZ s design allows faster chiller installation with a consequent reduction in commissioning cost. Standard factory functionality test Full refrigerant and oil charge Integrated Control Logic Single evaporator Single main power connection point Optional on-board inline dual-pumps Single Screw Compressor Single Screw Compressor Water pump selectable according to available pressure needs Electronic Expansion Device (EXXV) Coils 1 2 Coils Electronic Expansion Device (EXXV) Single Shell&Tube Evaporator equipped with Victaulic connections for an easy and fast hydraulic unit connection In-Built Redundancy Multiple Units on a Single Skid The EWAD-CZ unit is designed with two or three (depending on capacity) independent refrigerant circuits. All critical components (e.g. compressor, EEXV etc ) are independent on each circuit allowing for the highest reliability standards. Single Power Connection Point to simplify the installation reducing systems start-up costs

EWAD-C family Daikin EFFICIENCY LEADERSHIP 630 EWAD-CZXS/XL/XR ESEER 5.4 1,800 800 EWAD-C-PS/PL/PR ESEER 4.4 1,500 ESEER TYPICAL SCREW CHILLER EFFICIENCY LEVELS 730 EWAD-C-XS/XL/XR ESEER 4.2 2,000 620 EWAD-C-SS/SL/SR ESEER 3.9 1,900 kw 600 650 700 750 800 850 900 950 1,000 1,050 1,100 1,150 1,200 1,250 1,300 1,350 1,400 1,450 1,500 1,550 1,600 1,650 1,700 1,750 1,800 1,850 1,900 1,950 2,000 STEP 1 CHOOSE YOUR Daikin CHILLER EWAD-C Family 620-2,000 kw R-134a Single - Screw with VFD EWAD-BZ Family 100-620 kw R-134a Single - Screw with VFD EWAQ-E-/F- Family 170-680 kw R-410A MultiScroll STEP 2 CHOOSE YOUR Daikin AIR HANDING UNIT OR FAN COIL UNIT D-AHU Professional (800 m 3 /h - 140.000 m 3 /h) D-AHU Easy (500 m 3 /h - 30.000 m 3 /h) D-AHU Energy (1,500 m³/h -70,000 m³/h) Floor standing unit FWV-D (1.0 kw - 8.0 kw) Round flow cassette FWC-B (4.1 kw - 8.7 kw) Ducted unit FWB-B (1.3 kw - 10.3 kw) Daikin s unique position as a manufacturer of air conditioning equipment, compressors and refrigerants has led to its close involvement in environmental issues. For several years Daikin has had the intention to become a leader in the provision of products that have limited impact on the environment. This challenge demands the eco design and development of a wide range of products and an energy management system, resulting in energy conservation and a reduction of waste. The present leaflet is drawn up by way of information only and does not constitute an offer binding upon Daikin Europe N.V.. Daikin Europe N.V. has compiled the content of this leaflet to the best of its knowledge. No express or implied warranty is given for the completeness, accuracy, reliability or fitness for particular purpose of its content and the products and services presented therein. Specifications are subject to change without prior notice. Daikin Europe N.V. explicitly rejects any liability for any direct or indirect damage, in the broadest sense, arising from or related to the use and/or interpretation of this leaflet. All content is copyrighted by Daikin Europe N.V. FSC ECPEN11-801 ECPEN13-415 Daikin Europe N.V. participates in the Eurovent Certification programme for Air conditioners (AC), Liquid Chilling Packages (LCP) and Fan coil units (FCU), Check ongoing validity of certificate online: www.eurovent-certification.com or using: www.certiflash.com Daikin products are distributed by: Naamloze Vennootschap - Zandvoordestraat 300, B-8400 Oostende - Belgium - www.daikin.eu - BE 0412 120 336 - RPR Oostende ECPEN13-415 1000 10/12 Copyright Daikin Printed on non-chlorinated paper. Prepared by La Movida, Belgium Resp. Ed.: Daikin Europe N.V., Zandvoordestraat 300, B-8400 Oostende