SERIES 54 PROXIMITY SENSORS

Similar documents
SERIES 54 Inductive Proximity Sensor

Technical Data. Dimensions

SERIES 54 PROXIMITY SENSORS

SERIES 54 PROXIMITY SENSORS

2N1 TM PROXSENSOR ACCESSORIES VALVE STATUS MONITOR SERIES 52 2 INDUCTIVE PROXIMITY SENSORS AC, DC & INTRINSICALLY SAFE VERSIONS

Sensor boxes SRBE Key features and product range overview

GuaRdboX - Gd series IOM (Installation, Operation & Maintenance Manual) 0100-ENG rev.4

Electronic pressure switch. Type HEDE 10. Contents. Features. RE Edition: Replaces:

Electronic Limit Switch Type

Type Electronic Limit Switch

Limit switch attachments DAPZ

Accessories for pneumatic stroke and rotary actuators CLASSIC and ELEMENT process valves

Fieldbus Segment Protector F2-SP-IC* Features. Assembly. Function. Connection. Zone 2 Div. 2

Inductive Special Properties

Electronic pressure switch with two switching outputs

Electronic pressure switch with integrated analogue output

Linear actuators DFPI

CD34CNFLFxxx. Capacitive sensor, Foreground Suppression. Main features. Main functions. Description

Magnetic Field Sensor for pneumatic cylinders BIM-UNT-AP6X-0.3-PSG3S/3GD

T 3965 EN Type 3965 Solenoid Valve Island To control pneumatic actuators

Solenoid coils VACF Type codes

Ex m Solenoid Operator Type 0519

XT130B1NAL2 capacitive sensor - XT1 - cylindrical M30 - brass - Sn 10 mm - cable 2 m

CONTROLS. Bray Pneumatic Actuators & Accessories. Technical Manual. A Division of BRAY INTERNATIONAL, Inc.

Versions. Version with K VS Version with K VS 2.0. Fig. 1: Type 3967 Solenoid Valve

Integrated Control modules

XXV18B1PAL2 Ultrasonic sensor - M18 metal - Sn 50mm - PNP NO - cable 2m

97300 NAMUR 3/2 & 5/2 way spool valves electromagnetic actuated, indirectly controlled G 1/4, 1/4 NPT, NAMUR Interface

KEYSTONE F89 PNEUMATIC QUARTER-TURN ACTUATOR GENERAL PURPOSE / HAZARDOUS AREA

MFH MOFH JMFH JMFDH NVF3 MUFH VOFD VOFC VSNC VUVS

Integrated Control modules

For double-acting actuators. Crossover-free switching. Safety function in the event of power failure provided by mechanical return spring

Pneumatic control unit for decentralized automation of ELEMENT process valves

XMLRM01G1P25 Pressure sensors XMLR -1 bar - G 1/4-24VDC ma - PNP - M12

PMS - PKS / PMW - PKW series

Operating Instructions

L(+) SV1 N(-) NC. Terminal Block Connections L (+) N (-) SV1 K2 K1. Refer to "General Notes Relating to Pepperl+Fuchs Product Information".

DMK 331P. Industrial Pressure Transmitter. Pressure Ports With Flush Welded Stainless Steel Diaphragm. accuracy according to IEC 60770: 0.

LIMIT SWITCH Hawkeye - HX Magnetic Solid State Proximity Sensors Installation, Maintenance and Operating Instructions (HX )

XMLR160M2P05 Pressure sensors XMLR 160bar - G 1/4-24VDC - 2xPNP - M12

Capacitive level sensors CLS 23

DMK 331P. Industrial Pressure Transmitter. Pressure Ports With Flush Welded Stainless Steel Diaphragm

Control block VOFA with safety function

L(+) SV1 N(-) NC. Terminal Block Connections L (+) N (-) SV1 K2 K1. Refer to "General Notes Relating to Pepperl+Fuchs Product Information".

MS General Information Extended Product Type: MS

V82 series - Redundant valve manifold systems - Compact 1oo2 Safety, 2oo2 Availability and 2oo3 Safety and Availability

JUMO dtrans p35. Pressure Sensor with IO-Link. Application. Brief description. Customer benefits. Special features

Type Z & Ex pz purge and pressurization system

APS & APIS ATEX AIRPOWER SWITCH BOXES FEATURES DESCRIPTION

RI360P0-QR24M0- INCRX2-H1181 Contactless Encoder Incremental

SERIES 5A AND 5B VALVE STATUS MONITOR THE HIGH PERFORMANCE COMPANY BRAY SERIES 70 ELECTRIC ACTUATORS

DMP 331P DMP 331P. Industrial Pressure Transmitter. Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm

Climatic proofing Damp heat, constant, to IEC Damp heat, cyclic, to IEC mm

PHOENIX CONTACT - 01/2008

Solenoid Valve Island Type 3965

DMK 331P DMK 331P. Industrial Pressure Transmitter. Pressure Ports With Flush Welded Stainless Steel Diaphragm. Pressure Transmitter.

B Mini Contactor V Hz

Solenoid coil for control in potentially explosive areas Type BZ

Keystone F89 pneumatic quarter-turn actuator General purpose / hazardous area

KEYSTONE F89 pneumatic quarter-turn actuator GENERAL PURPOSE / HAZARDOUS AREA

DMP 333. Industrial Pressure Transmitter For High Pressure. Stainless Steel Sensor

INLINE Flow sensor for hazardous area II 1 G/D - II 2 D - II 3 GD - I M1

Proximity sensors SMT/SME-10, for C-slot

15 mm Pilot Valve. More technical specifications are reported in the following pages. 1

INSTRUCTION MANUAL (ATEX / IECEx)

I r A short-circuit protective device: Observe the maximum permissible fuse of the contactor with direct device mounting.

USER s MANUAL 1. GENERAL INFORMATION 2. PRODUCT IDENTIFICATION

DMP 331P. Industrial Pressure Transmitter. Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm

DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor

Instructions Contact numbers to EN Coil terminal markings to EN Integrated diode-resistor combination Coil rating 2.

Operating Instructions

Material pressure (bar) (Cv (US) kv x 1,2 Seat

Series 3730 Electropneumatic Positioner Type

Type 2511/12. Type Type 2030 Cable plug. ASI cable plug. Dosing control. General technical data Orifice Type 6518

DMP 331 DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor. Pressure Transmitter. Industrial

26230, NAMUR 3/2 & 5/2 Indirect solenoid actuated spool valves

ExBin-P Pressure switches 5 Pa Pa

XMLR400M1N75 Pressure sensors XMLR 400bar - G 1/4-24VDC V - NPN - M12

Solenoid System. The coil is also in conformity with 94/9/EC ATEX for electrical apparatus of group II, category 3 (Ex na II 3 GD T4 or T5).

3/2 and 4/2 directional seat valves with solenoid actuation

Contactless Encoder with Stainless Steel Housing Incremental: ppr RI360P0-EQR24M0- INCRX2-H1181

SG-B1 SERIES / SG-A1 SERIES

Product series DSA, DSB, DSC, DSD


INSTRUCTION MANUAL (ATEX / IECEx)

Operating Instructions

Limit Switch Type 3776

Datasheet. Electrical Switching / Locking

Ex-proof proportional relief valves Direct or pilot operated, without transducer - ATEX, IECEx, EAC or CULUS

Proximity switches and switch brackets

EPS 16 ATEX 1072 X, IECEx EPS X. Operating Instructions. Solenoid coil Type AC19 Magnetspule Typ AC19 Bobine magnétique Type AC19

Instructions Contact numbers to EN Coil terminal markings to EN Integrated diode-resistor combination Coil rating 2.

SPOOL VALVES solenoid air operated 1/4 to 1/2 tapped body and NAMUR for integrated pilot

HERION SERIES Indirect solenoid actuated soft seal

Sx-F/G-SG-ST SERIES APPLICATIONS

BC Mini Contactor VDC

Magnetic switch For bypass level indicators Model BGU for nuclear power plants

Solenoid valves VUVS/valve manifold VTUS, NPT

Keystone F89C Pneumatic Quarter-Turn Actuator Chemical Industry / Hazardous area

Solenoid System KNURLED NUT TOP CORE GUIDE TUBE PLUNGER

Transcription:

SERIES 54 PROXIMITY SENSORS Technical Manual BRAY.COM THE HIGH PERFORMANCE COMPANY

TABLE OF CONTENTS GENERAL SERVICE DC 3-wire PNP 540021-71104533... S1-1 DC 2-wire 540022-71104533... S2-1 DC 2-wire + terminal compartment 540032-71104533... S3-1 INDUSTRIAL SERVICE DC 3-wire PNP 540001-71104533...S4-1 DC 3-wire PNP + solenoid out 540041-71104533... S5-1 AS-i + solenoid output 540005-71104533... S6-1 AS-i + solenoid output + terminal compartment 540015-71104533... S7-1 AC/DC Sensor 540004-71104533... S8-1 HAZARDOUS SERVICE DC 2 + solenoid output + terminal compartment 540102-126xx536... S9-1 ACTIVATORS Non adjustable Activator 54-063B... S10-1 Adjustable Activator 54-063A...S11-1 High Visibility & Adjustable Activator 54-063C...S12-1

General Service DC 3-wire PNP 540021-71104533 SENSOR FEATURES > DC 3-wire PNP sensor > IP 67 rugged plastic housing > Hermetically sealed > Vibration, shock and corrosion resistant > Small, compact design > High visibility LED for power and switch status > Quick Installation DIMENSIONS ø 5.3 40 LED R20.8 30 52 20 13 7 ACTIVATOR M12x1 11 52 LED 45 45 Activator sold separately TECHNICAL DATA General specifications Switching function Output type 2 x normally open (NO) PNP, 3-wire Rated operating distance sn 4 mm Installation Output polarity Flush mountable DC Assured operating distance sa 0... 3.24 mm Actual operating distance sr 3.6... 4.4 mm typ. Nominal ratings Operating voltage UB 10... 30 V DC Switching frequency f 0... 1000 Hz Hysteresis H Typ. 5 % Reverse polarity protection Short-circuit protection Reverse polarity protected Pulsing Voltage drop Ud 2.5 V Operating current IL 0... 200 ma Off-state current Ir 0... 0.5 ma typ. 0.1 μa at 25 C No-load supply current IO 22.5 ma Time delay before availability tv 100 ms Operating voltage indicator Switching state indicator Ambient conditions LED, green LED, yellow Ambient temperature TA -25... 70 C (-13... 158 F) Storage temperature Mechanical specifications Connection type Housing material Sensing face material Degree of protection Mass Tightening torque, fastening screws Compliance with standards and directives -40... 85 C (-40... 185 F) Connector M12 x 1, 4-pin PBT PC IP67 48g M5 x 25 : 2.7Nm Standards EN 60947-5-2:2007 EN 60947-5-2/A1:2012 Approvals and certificates UL approval CCC approval culus listed, general purpose IEC 60947-5-2:2007 IEC 60947-5-2 AMD 1:2012 Approval and marking not required for products rated 36 V S1-1 of 2

General Service DC 3-wire PNP 540021-71104533 ACTIVATOR AND MOUNTING KITS 30 x 80 mm NAMUR Mounting, non adjustable 54063B-14850536 Fits Bray S92/93 Sizes 63 to 93 and Series 98 - Metric 54063B-14800536 Fits Bray S92/93 Sizes 63 to 93 - Imperial 30 x 130 mm NAMUR Mounting, non adjustable 54119B-14850536 Fits Bray S92/93 Sizes 119 to 255 - Metric 54119B-14800536 Fits Bray S92/93 Sizes 119 to 210 - Imperial ACCESSORIES 090005-76145882 Sensor Cordset - M12 female straight connector to flying leads, 4-pin, 5 meters, zinc 090004-76145534 Sensor Cordset - M12 female straight connector to flying leads, 4-pin, 5 meters, stainless steel 600250-23663536 Y-Connector Cordset (S62, S63) - M12 male straight connector, 5-pin (system side) to M12 female straight connector, 4-pin (sensor side) AND Type I valve connector (DIN 43650) 600250-23666536 Y-Connector Cordset (S60) - M12 male straight connector, 5-pin (system side) to M12 female straight connector, 4-pin (sensor side) AND Form A valve connector (DIN 43650) 630250-21524536 Series 63 - Valve Solenoid, NAMUR mount 3/2 or 5/2, Form B connector (DIN 43560), IP65, single 24vdc coil 621250-21524536 Series 62 - Valve Solenoid, NAMUR mount 3/2 or 5/2, Form B connector (DIN 43560), IP65, single 24vdc coil WIRING DIAGRAM CONNECTOR PINOUT I II I II I 1 4 2 3 L+ L- 2 1 4 3 Wire colors in accordance with EN 60947-5-2 1 BN (brown) 2 WH (white) 3 BU (blue) 4 BK (black) All information herein is proprietary, confidential, and may not be copied or reproduced without the expressed written consent of Bray International, Inc. The technical data herein is for general information only. Product suitability should be based solely upon customer s detailed knowledge and experience with their application. Bray is a registered trademark of Bray International, Inc. 2017 Bray International. All rights reserved. TM-BC-1064_S54_0021_EU-EN_2017-12-13 S1-2 of 2

General Service DC 2-wire 540022-71104533 SENSOR FEATURES > DC 2-wire sensor > IP 67 rugged plastic housing > Hermetically sealed > Vibration, shock and corrosion resistant > Small, compact design > High visibility LED for power and switch status > Min off state current optimized for PLCs DIMENSIONS ø 5.3 40 LED R20.8 30 52 20 13 7 ACTIVATOR M12x1 11 52 LED 45 45 Activator sold separately TECHNICAL DATA General specifications Switching function Output type 2 x normally open (NO) Two-wire Rated operating distance sn 4mm Installation Output polarity Flush mountable DC Assured operating distance sa 0... 3.24 mm Actual operating distance sr 3.6... 4.4 mm typ. Output type Nominal ratings 2 x 2-wire Operating voltage UB 5... 30 V DC Switching frequency f 0... 500 Hz Hysteresis H Typ. 5 % Reverse polarity protection Short-circuit protection Reverse polarity protected Pulsing Voltage drop Ud 4.5 V Operating current IL 4... 100mA Off-state current Ir 120... 200 μa typ. 175 μa at +25 C Time delay before availability tv 100 ms Switching state indicator Valve status indicator Ambient conditions LED, yellow LED, yellow Ambient temperature TA -25... +70 C (-13... +158 F) Storage temperature Mechanical specifications Connection type Housing material Sensing face material Degree of protection Mass Tightening torque, fastening screws Compliance with standards and directives -40... +85 C (-40... +185 F) Connector M12 x 1, 4-pin PBT PC IP67 49 g M5 x 25 : 2.7 Nm Standards EN 60947-5-2:2007 EN 60947-5-2/A1:2012 Approvals and certificates UL approval CCC approval culus listed, general purpose IEC 60947-5-2:2007 IEC 60947-5-2 AMD 1:2012 Approval and marking not required for products rated 36 V S2-1 of 2

General Service DC 2-wire 540022-71104533 ACTIVATOR AND MOUNTING KITS 30 x 80 mm NAMUR Mounting, non adjustable 54063B-14850536 Fits Bray S92/93 Sizes 63 to 93 and Series 98 - Metric 54063B-14800536 Fits Bray S92/93 Sizes 63 to 93 - Imperial 30 x 130 mm NAMUR Mounting, non adjustable 54119B-14850536 Fits Bray S92/93 Sizes 119 to 255 - Metric 54119B-14800536 Fits Bray S92/93 Sizes 119 to 210 - Imperial ACCESSORIES 090005-76145882 Sensor Cordset - M12 female straight connector to flying leads, 4-pin, 5 meters, zinc 090004-76145534 Sensor Cordset - M12 female straight connector to flying leads, 4-pin, 5 meters, stainless steel WIRING DIAGRAM CONNECTOR PINOUT I I 1 4 2 L+ L- L+ 2 1 4 II II 3 L- 3 Wire colors in accordance with EN 60947-5-2 1 BN (brown) 2 WH (white) 3 BU (blue) 4 BK (black) All information herein is proprietary, confidential, and may not be copied or reproduced without the expressed written consent of Bray International, Inc. The technical data herein is for general information only. Product suitability should be based solely upon customer s detailed knowledge and experience with their application. Bray is a registered trademark of Bray International, Inc. 2017 Bray International. All rights reserved. TM-BC-1068_S54_0022_EU-EN_2017-12-13 S2-2 of 2

General Service DC 2-wire + terminal compartment 540032-71104533 SENSOR FEATURES > DC 2-wire sensor with plugin terminal > IP 67 rugged plastic housing > Hermetically sealed > Vibration, shock and corrosion resistant > Small, compact design > High visibility LED for power and switch status > Min off state current optimized for PLCs > Sensor electronics sealed from terminal compartment DIMENSIONS ø 5.3 40 69 7 R20.8 ACTIVATOR 45 45 30 52 20 M20x1.5 13 37.5 TECHNICAL DATA General specifications Switching function Output type 2 x normally open (NO) Two-wire Rated operating distance sn 4mm Installation Output polarity Flush mountable DC Assured operating distance sa 0... 3.24 mm Actual operating distance sr 3.6... 4.4 mm typ. Output type Nominal ratings 2 x 2-wire Operating voltage UB 5... 30 V DC Switching frequency f 0... 500 Hz Hysteresis H Typ. 5 % Reverse polarity protection Short-circuit protection Reverse polarity protected Pulsing Voltage drop Ud 4.5 V Operating current IL 4... 100mA Off-state current Ir 120... 200 μa typ. 175 μa at +25 C Time delay before availability tv 100 ms Switching state indicator Valve status indicator Ambient conditions LED, yellow LED, yellow Ambient temperature TA -25... +70 C (-13... +158 F) Storage temperature Mechanical specifications Connection type Housing material Sensing face material Degree of protection Mass Tightening torque, fastening screws Compliance with standards and directives -40... +85 C (-40... +185 F) Screw terminal, M20 x 1.5 cable gland PBT PC IP67 98 g M5 x 25 : 2.7 Nm Standards EN 60947-5-2:2007 EN 60947-5-2/A1:2012 Approvals and certificates UL approval CCC approval culus listed, general purpose IEC 60947-5-2:2007 IEC 60947-5-2 AMD 1:2012 Approval and marking not required for products rated 36 V Activator sold separately S3-1 of 2

General Service DC 2-wire + terminal compartment 540032-71104533 WIRING DIAGRAM 1 I I 2 3 6 4 II II 5 S I+ S I- n. c. S II+ S II- ACTIVATOR AND MOUNTING KITS 30 x 80 mm NAMUR Mounting, non adjustable 54063B-14850536 Fits Bray S92/93 Sizes 63 to 93 and Series 98 - Metric 54063B-14800536 Fits Bray S92/93 Sizes 63 to 93 - Imperial 30 x 130 mm NAMUR Mounting, non adjustable 54119B-14850536 Fits Bray S92/93 Sizes 119 to 255 - Metric 54119B-14800536 Fits Bray S92/93 Sizes 119 to 210 - Imperial All information herein is proprietary, confidential, and may not be copied or reproduced without the expressed written consent of Bray International, Inc. The technical data herein is for general information only. Product suitability should be based solely upon customer s detailed knowledge and experience with their application. Bray is a registered trademark of Bray International, Inc. 2017 Bray International. All rights reserved. TM-BC-1067_S54_0032_EU-EN_2017-12-06 S3-2 of 2

Industrial Service DC 3-wire PNP 540001-71104533 SENSOR FEATURES > DC 3-wire PNP sensor > IP 67 rugged plastic housing > Hermetically sealed > Vibration, shock and corrosion resistant > Compact design > High visibility LED for power and switch status DIMENSIONS ø 5.3 40 LED 7 R20.8 ACTIVATORS M12x1 11 LED 52 LED 45 45 30 52 20 13 Activators sold separately TECHNICAL DATA General specifications Switching function Output type Rated operating distance sn 3 mm Installation Output polarity 2 x normally open (NO) PNP, 3-wire Flush mountable DC Assured operating distance sa 0... 2.43 mm Actual operating distance sr 2.7... 3.3 mm typ. Nominal ratings Operating voltage UB 10... 30 V DC Switching frequency f 0... 500 Hz Hysteresis H Typ 5 % Reverse polarity protection Short-circuit protection All connections Pulsing Voltage drop Ud 3 V Operating current IL 0... 100 ma Off-state current Ir 0... 0.5 ma typ. 0.1 μa at 25 C No-load supply current IO 25 ma Operating voltage indicator Switching state indicator Functional safety related parameters MTTFd Mission Time (TM) LED, green LED, yellow 780 a 20 a Diagnostic Coverage (DC) 0% Ambient conditions Ambient temperature TA -25... 70 C (-13... 158 F) Mechanical specifications Connection (system side) Housing material Sensing face material Degree of protection Standard conformity 4-pin, M12 x 1 connector PBT PBT IP67 Standards EN 60947-5-2:2007 EN 60947-5-2/A1:2012 Approvals and certificates UL approval CCC approval culus listed, general purpose IEC 60947-5-2:2007 IEC 60947-5-2 AMD 1:2012 Approval and marking not required for products rated 36 V S4-1 of 2

Industrial Service DC 3-wire PNP 540001-71104533 ACTIVATOR AND MOUNTING KITS 30 x 80 mm NAMUR Mounting, adjustable 54063A-14850536 Fits Bray S92/93 Sizes 63 to 128 and Series 98 - Metric 54063A-14800536 Fits Bray S92/93 Sizes 63 to 128 - Imperial 30 x 130 mm NAMUR Mounting, adjustable 54160A-14850536 Fits Bray S92/93 Sizes 160 to 255 - Metric 54160A-14800536 Fits Bray S92/93 Sizes 160 to 210 - Imperial 30 x 80 mm NAMUR Mounting, adjustable, High Visibility 54063C-14850536 Fits Bray S92/93 Sizes 63 to 128 and Series 98 - Metric 54063C-14800536 Fits Bray S92/93 Sizes 63 to 128 - Imperial 30 x 130 mm NAMUR Mounting, adjustable, High Visibility 54160C-14850536 Fits Bray S92/93 Sizes 160 to 255 - Metric 54160C-14800536 Fits Bray S92/93 Sizes 160 to 210 - Imperial ACCESSORIES 090005-76145882 Sensor Cordset - M12 female straight connector to flying leads, 4-pin, 5 meters, zinc 090004-76145534 Sensor Cordset - M12 female straight connector to flying leads, 4-pin, 5 meters, stainless steel 600250-23663536 Y-Connector Cordset (S62, S63) - M12 male straight connector, 5-pin (system side) to M12 female straight connector, 4-pin (sensor side) AND Type I valve connector (DIN 43650) 600250-23666536 Y-Connector Cordset (S60) - M12 male straight connector, 5-pin (system side) to M12 female straight connector, 4-pin (sensor side) AND Form A valve connector (DIN 43650) 630250-21524536 Series 63 - Valve Solenoid, NAMUR mount 3/2 or 5/2, Form B connector (DIN 43560), IP65, single 24vdc coil 621250-21524536 Series 62 - Valve Solenoid, NAMUR mount 3/2 or 5/2, Form B connector (DIN 43560), IP65, single 24vdc coil WIRING DIAGRAM CONNECTOR PINOUT I I II I 1 4 2 L+ II 3 L- Wire colors in accordance with EN 60947-5-2 1 BN (brown) 2 WH (white) 3 BU (blue) 4 BK (black) All information herein is proprietary, confidential, and may not be copied or reproduced without the expressed written consent of Bray International, Inc. The technical data herein is for general information only. Product suitability should be based solely upon customer s detailed knowledge and experience with their application. Bray is a registered trademark of Bray International, Inc. 2017 Bray International. All rights reserved. TM-BC-1065_S54_0001_EU-EN_2017-12-15 S4-2 of 2

Industrial Service DC 3-wire PNP + solenoid out 540041-71104533 SENSOR FEATURES > DC 3-wire PNP sensor > IP 67 rugged plastic housing > Hermetically sealed > Vibration, shock and corrosion resistant > Compact design > High visibility LED for power and switch status > System cable supports power for sensor and solenoid DIMENSIONS LED 36 33.5 5 7 V 5.4 M12 x 1 ACTIVATORS 9 30 65 Activators sold separately I II RD24x1/8 S 25 14 TECHNICAL DATA General specifications Switching function Output type Rated operating distance sn 3 mm Installation Output polarity 2 x normally open (NO) PNP, 3-wire Flush mountable DC Assured operating distance sa 0... 2.43 mm Nominal ratings Operating voltage UB 10... 30 V DC Switching frequency f 0... 500 Hz Hysteresis H Typ. 5% Reverse polarity protection Short-circuit protection All connections Pulsing Voltage drop Ud 3 V Operating current ll 0... 100 ma Off-state current lr 0... 0.5 ma typ. 0.1 μa at +25 C No-load supply current l0 25 ma Operating voltage display Switching state indication Functional safety related parameters MTTFd Mission Time (TM) LED, green LED, yellow 780 a 20 a Diagnostic Coverage (DC) 0% Ambient conditions Ambient temperature TA 25... +70 C (-13... +158 F) Mechanical specifications Connection (system side) Connection (valve side) Housing material Sensing face material Degree of protection Note Standard conformity Rd24 x 1/8, 6-pin+PE Socket connector, M12 x 1, 4-pin PBT PBT IP67 Standards EN 60947-5-2:2007 EN 60947-5-2/A1:2012 Approvals and certificates UL approval CCC approval Valve voltage limited to 26,4 V max.; valve power 6 W max. culus listed, general purpose IEC 60947-5-2:2007 IEC 60947-5-2 AMD 1:2012 Approval and marking not required for products rated 36 V S5-1 of 2

Industrial Service DC 3-wire PNP + solenoid out 540041-71104533 ACTIVATOR AND MOUNTING KITS 30 x 80 mm NAMUR Mounting, non adjustable 54063A-14850536 Fits Bray S92/93 Sizes 63 to 128 and Series 98 - Metric 54063A-14800536 Fits Bray S92/93 Sizes 63 to 128 - Imperial 30 x 130 mm NAMUR Mounting, non adjustable 54160A-14850536 Fits Bray S92/93 Sizes 160 to 255 - Metric 54160A-14800536 Fits Bray S92/93 Sizes 160 to 210 - Imperial 30 x 80 mm NAMUR Mounting, adjustable, High Visibility 54063C-14850536 Fits Bray S92/93 Sizes 63 to 128 and Series 98 - Metric 54063C-14800536 Fits Bray S92/93 Sizes 63 to 128 - Imperial 30 x 130 mm NAMUR Mounting, adjustable, High Visibility 54160C-14850536 Fits Bray S92/93 Sizes 160 to 255 - Metric 54160C-14800536 Fits Bray S92/93 Sizes 160 to 210 - Imperial ACCESSORIES 090700-71155517 Sensor Cordset - single ended Rd24 female 6-pin + PE straight socket with screw terminal for field wiring. Field attachable. 090001-76159882 S-Connector Cordset (S62, S63) - M12 male right angle to Form B valve conector (DIN 43650), 2-pins+PE, 0.6 meters 090001-76160882 S-Connector Cordset (S60) - M12 male right angle to Form A valve connector (DIN 43650), 2-pins+PE, 0.3 meters 630250-21524536 Series 63 - Valve Solenoid, NAMUR mount 3/2 or 5/2, Form B connector (DIN 43560), IP65, single 24vdc coil 621250-21524536 Series 62 - Valve Solenoid, NAMUR mount 3/2 or 5/2, Form B connector (DIN 43560), IP65, single 24vdc coil WIRING DIAGRAM CONNECTOR PINOUT 1 2 3 4 5 6 1 3 2 4 System Side Valve Side Compatible with 4-pin connector All information herein is proprietary, confidential, and may not be copied or reproduced without the expressed written consent of Bray International, Inc. The technical data herein is for general information only. Product suitability should be based solely upon customer s detailed knowledge and experience with their application. Bray is a registered trademark of Bray International, Inc. 2017 Bray International. All rights reserved. TM-BC-1063_S54_0041_EU-EN_2017-12-06 S5-2 of 2

Industrial Service AS-i + solenoid output 540005-71104533 SENSOR FEATURES > AS-i sensor > A/B slave with extended addressing possibility for up to 62 devices > Interoperable with higher-level BUS systems > Protection degree IP67 > Communication monitoring, turn-off > Lead breakage and short-circuit monitoring of solenoid valve > System cable supports power and data > Two M12 connections DIMENSIONS Drawing without actuator ACTIVATORS Sensor I Sensor II TECHNICAL DATA General specifications Switching element function Rated operating distance sn 3 mm Installation Output polarity Programmable Flush mountable AS-Interface Assured operating distance sa 0... 2.43 mm Slave type AS-Interface specification V3.0 A/B slave Required master specification V2.1 Nominal ratings Operating voltage UB 26.5... 31.9 V via AS-i bus system Switching frequency f 0... 100 Hz No-load supply current I0 35 ma Functional safety related parameters MTTFd Mission Time (TM) 842 a 20 a Diagnostic Coverage (DC) 0% Indicators/operating means LED PWR LED IN LED OUT Electrical specifications AS-Interface voltage; LED green Switching state (input); LED yellow Binary LED yellow/red; yellow: switching state red: lead breakage/short-circuit Rated operational voltage Ue 26.5... 31.6 V from AS-Interface Rated operational current Ie 100 ma Ambient conditions Ambient temperature TA -25... 70 C (-13... 158 F) Mechanical specifications Connection (system side) Connection (valve side) Housing material Sensing face material Degree of protection Note Standard conformity Connector M12 x 1, 4-pin Socket connector, M12 x 1, 4-pin PBT PBT IP67 Valve voltage limited to 26,4 V max.; valve power 2,5 W max. Electromagnetic compatibility EN 50295:1999-10 Standards EN 60947-5-2:2007 EN 60947-5-2/A1:2012 Approvals and certificates UL approval CCC approval culus listed, general purpose IEC 60947-5-2:2007 IEC 60947-5-2 AMD 1:2012 Approval and marking not required for products rated 36 V Activators sold separately S6-1 of 3

Industrial Service AS-i + solenoid output 540005-71104533 WIRING DIAGRAM ACTIVATOR AND MOUNTING KITS 30 x 80 mm NAMUR Mounting, adjustable 54063A-14850536 Fits Bray S92/93 Sizes 63 to 128 and Series 98 - Metric 54063A-14800536 Fits Bray S92/93 Sizes 63 to 128 - Imperial 30 x 130 mm NAMUR Mounting, adjustable 54160A-14850536 Fits Bray S92/93 Sizes 160 to 255 - Metric 54160A-14800536 Fits Bray S92/93 Sizes 160 to 210 - Imperial 30 x 80 mm NAMUR Mounting, adjustable, High Visibility 54063C-14850536 Fits Bray S92/93 Sizes 63 to 128 and Series 98 - Metric 54063C-14800536 Fits Bray S92/93 Sizes 63 to 128 - Imperial 30 x 130 mm NAMUR Mounting, adjustable, High Visibility 54160C-14850536 Fits Bray S92/93 Sizes 160 to 255 - Metric 54160C-14800536 Fits Bray S92/93 Sizes 160 to 210 - Imperial ACCESSORIES 090005-76145882 Sensor Cordset - M12 female straight connector to flying leads, 4-pin, 5 meters, zinc 090004-76145534 Sensor Cordset - M12 female straight connector to flying leads, 4-pin, 5 meters, stainless steel 090402-711555ZT Sensor Cordset - single ended M12 female 4-pin straight socket with screw terminal for field wiring. Field attachable. 66A000-14205533 Sensor Cordset - AS-i M12 female to flat cable piercing method 090001-76160882 S-Connector Cordset (S60) - M12 male right angle to Form A valve connector (DIN 43650), 2-pins+PE, 0.3 meters 600250-21540536 Series 60 -Valve Solenoid, Low Power (0.7W), NAMUR mount 5/2, Form A connector (DIN 43560), IP65, single 24vdc coil CONNECTOR PINOUT Valve Connection Valve Connection LED OUT INSTALLATION Sensor I Sensor II The Series 54 is an inductive dual sensor used to indicate the valve positioning of actuators. The dual sensor is mounted directly on the actuator using two screws. Additional adjustment is not necessary. A switch box M12 x 1 on the sensor is used directly for the valve controls. The Series 54 is connected via a M12x1 screw fixing to the bus line. This makes it possible to transmit both the switch signal for the valve and the messages of the sensors via AS-Interface. They are both powered directly through the bus cable. Moreover, the valve is monitored for lead breakage and short circuit. The D1 data bit monitors the fault signal. The sensors can be programmed as normally closed and normally open contacts (parameter bit P1 and P2). If there are no communications on the bus cable, the valve is automatically de-energised. This communication monitoring can be turned off via the parameter bit P0. Valve Connection S6-2 of 3

Industrial Service AS-i + solenoid output 540005-71104533 SUPPLEMENTARY INFORMATION Programming Instructions Address 00 preset, alterable via Busmaster or programming units IO-code D ID-code A ID1-code 7 ID2-code E Data bit Bit Function D0 valve status (0=valve OFF, 1=valve ON) D1 valve fault 1 ) (0=lead breakage/short circuit; 1=no fault) D2 switch output sensor 1 2 ) (0=damped; 1=undamped) D3 switch output sensor 2 2 ) (0=damped; 1=undamped) Parameter bit Bit Function P0 Watchdog (0=inactive; 1=active) 3) P1 switching element function sensor II 4) (0=NO; 1= NC) P2 switching element function sensor I 4) (0=NO; 1= NC) P3 not used 1) Verification only with actuated valve (D0=1) 2) Applies to NC function (P2/P3=1; preset), with NO function (P2/P3=0) reversed characteristics 3) Watchdog active: valve voltage drops with the occurrence of an AS-I communication fault 4) Default setting: NC All information herein is proprietary, confidential, and may not be copied or reproduced without the expressed written consent of Bray International, Inc. The technical data herein is for general information only. Product suitability should be based solely upon customer s detailed knowledge and experience with their application. Bray is a registered trademark of Bray International, Inc. 2017 Bray International. All rights reserved. TM-BC-1066_S54_0005_EU-EN_2017-12-15 S6-3 of 3

Industrial Service AS-i + solenoid output + terminal compartment 540015-71104533 SENSOR FEATURES > AS-i sensor > A/B slave with extended addressing possibility for up to 62 devices > Interoperable with higher-level BUS systems > Protection degree IP67 > Communication monitoring, turn-off > System cable supports power and data > Lead breakage and short-circuit monitoring of solenoid valve > Two M20 x 1.5 system connections > One M12 x 1.5 valve connection > Large terminal space for ease of wiring > Sensor electronics sealed from terminal compartment DIMENSIONS LED ACTIVATORS Activators sold separately TECHNICAL DATA General specifications Switching element function Rated operating distance Installation Output polarity Assured operating distance Slave type Programmable 3mm AS-Interface specification V3.0 Flush mountable AS-Interface 0... 2.43 mm A/B slave Required master specification V2.1 Nominal ratings Operating voltage Switching frequency No-load supply current Functional safety related parameters MTTFd Mission Time (TM) 26.5... 31.9 V via AS-i bus system 0... 100 Hz 35 ma 842 a 20 a Diagnostic Coverage (DC) 0 % Indicators/operating means LED PWR LED IN LED OUT Electrical specifications Rated operational voltage Rated operational current Ambient conditions Ambient temperature Mechanical specifications AS-Interface voltage; LED green Switching state (input); LED yellow Binary LED yellow/red; yellow: switching state red: lead breakage/short-circuit 26.5... 31.6 V from AS-Interface 100 ma -25... +70 C (-13... +158 F) Connection (system side) Screw terminals, M20 x 1.5, Cable gland, Qty 2 Core cross-section (system side) 1.5/2.5 mm2 flexible/rigid Connection (valve side) Screw terminals M12 x 1.5, Cable gland, Qty 1 Core cross-section (valve side) Housing material Sensing face material Degree of protection Tightening torque, housing screws 1.5/2.5 mm2 flexible/rigid PBT PBT IP67 1 Nm S7-1 of 2

Industrial Service AS-i + solenoid output + terminal compartment 540015-71104533 WIRING DIAGRAM TECHNICAL DATA Tightening torque, cable gland Note Standard conformity M20 x 1.5 ; 7 Nm M12 x 1.5 ; 3 Nm Valve voltage limited to 26,4 V max.; valve power 2,5 W max. Electromagnetic compatibility EN 50295:1999-10 Standards EN 60947-5-2:2007 EN 60947-5-2/A1:2012 Approvals and certificates UL approval CCC approval culus listed, general purpose IEC 60947-5-2:2007 IEC 60947-5-2 AMD 1:2012 Approval and marking not required for products rated 36 V APPLICATION Note: The connections to this sensor are sealed with stopping plugs to protect against dirt and moisture. If not all of the connections are used in your application, then seal the remaining stopping plugs on the sensor permanently or check during initial installation and when performing regular maintenance work that the stopping plugs are secure and impermeable. If necessary, tighten the stopping plugs to a torque of 1 Nm. ACTIVATOR AND MOUNTING KITS 30 x 80 mm NAMUR Mounting, non adjustable 54063A-14850536 Fits Bray S92/93 Sizes 63 to 128 and Series 98 - Metric 54063A-14800536 Fits Bray S92/93 Sizes 63 to 128 - Imperial 30 x 130 mm NAMUR Mounting, non adjustable 54160A-14850536 Fits Bray S92/93 Sizes 160 to 255 - Metric 54160A-14800536 Fits Bray S92/93 Sizes 160 to 210 - Imperial 30 x 80 mm NAMUR Mounting, adjustable, High Visibility 54063C-14850536 Fits Bray S92/93 Sizes 63 to 128 and Series 98 - Metric 54063C-14800536 Fits Bray S92/93 Sizes 63 to 128 - Imperial 30 x 130 mm NAMUR Mounting, adjustable, High Visibility 54160C-14850536 Fits Bray S92/93 Sizes 160 to 255 - Metric 54160C-14800536 Fits Bray S92/93 Sizes 160 to 210 - Imperial ACCESSORIES 090005-76148533 S-Connector cordset (S60) - DIN Type A (DIN 43650) to flying leads, 4-Pins, 3 conductor, PUR, 5 meters 600250-21540536 Series 60 -Valve Solenoid, low power (0.7W), NAMUR mount 5/2, Form A connector (DIN 43560), IP65, single 24vdc coil WIRING DIAGRAM Programming Instructions Address 00 preset, alterable via Busmaster or programming units IO-code D ID-code A ID1-code 7 ID2-code E Data bit Bit Function D0 valve status (0=valve OFF, 1=valve ON) D1 valve fault 1 ) (0=lead breakage/short circuit; 1=no fault) D2 switch output sensor 1 2 ) (0=damped; 1=undamped) D3 switch output sensor 2 2 ) (0=damped; 1=undamped) Parameter bit Bit Function P0 Watchdog (0=inactive; 1=active) 3) P1 switching element function sensor II 4) (0=NO; 1= NC) P2 switching element function sensor I 4) (0=NO; 1= NC) P3 not used 1) Verification only with actuated valve (D0=1) 2) Applies to NC function (P2/P3=1; preset), with NO function (P2/P3=0) reversed characteristics 3) Watchdog active: valve voltage drops with the occurrence of an AS-I communication fault 4) Default setting: NC All information herein is proprietary, confidential, and may not be copied or reproduced without the expressed written consent of Bray International, Inc. The technical data herein is for general information only. Product suitability should be based solely upon customer s detailed knowledge and experience with their application. Bray is a registered trademark of Bray International, Inc. 2017 Bray International. All rights reserved. TM-BC-1069_S54_0015_EU-EN_2017-12-15 S7-2 of 2

II I SERIES 54 Inductive Proximity Sensor Industrial Service AC/DC Sensor 540004-71104533 SENSOR FEATURES > AC/DC sensor > IP67 rugged plastic housing > Hermetically sealed > Vibration, shock and corrosion resistant > Compact design > High visibility LED for power and switch status > Quick installation DIMENSIONS 7/8-16 LED 30 65 25 14 5.4 9 ACTIVATORS Activators sold separately 36 7 33.5 5 TECHNICAL DATA General specifications Switching function Output type 2 x normally open (NO) Two-wire Rated operating distance sn 3 mm Installation Output polarity Flush mountable AC/DC Assured operating distance sa 0... 2.43 mm Output type Nominal ratings 4-wire Operating voltage UB 20... 250 V AC/DC Switching frequency f 25 Hz Hysteresis H Typ. 3 % Reverse polarity protection Short-circuit protection Yes Yes Voltage drop Ud 8 V Operating current ll 4... 400 ma Off-state current lr 1.7 ma Operating voltage indicator Switching state indicator Ambient conditions LED, green LED, yellow Ambient temperature TA -25... +70 C (-13... +158 F) Storage temperature Mechanical specifications Connection (system side) Housing material Sensing face material Degree of protection Housing Mass Standard conformity -40... +100 C (-40... +212 F) V95 connector (7/8-16 UN 2A), 5-pin PBT PBT IP67 PBT 90 g Standards EN 60947-5-2:2007 EN 60947-5-2/A1:2012 Approvals and certificates Protection class Rated insulation voltage Ul 253 V Rated impulse withstand voltage Uimp 4 kv UL approval II culus listed, general purpose IEC 60947-5-2:2007 IEC 60947-5-2 AMD 1:2012 S8-1 of 2

Industrial Service AC/DC Sensor 540004-71104533 ACTIVATOR AND MOUNTING KITS 30 x 80 mm NAMUR Mounting, non adjustable 54063A-14850536 Fits Bray S92/93 Sizes 63 to 128 and Series 98 - Metric 54063A-14800536 Fits Bray S92/93 Sizes 63 to 128 - Imperial 30 x 130 mm NAMUR Mounting, non adjustable 54160A-14850536 Fits Bray S92/93 Sizes 160 to 255 - Metric 54160A-14800536 Fits Bray S92/93 Sizes 160 to 210 - Imperial 30 x 80 mm NAMUR Mounting, adjustable, High Visibility 54063C-14850536 Fits Bray S92/93 Sizes 63 to 128 and Series 98 - Metric 54063C-14800536 Fits Bray S92/93 Sizes 63 to 128 - Imperial 30 x 130 mm NAMUR Mounting, adjustable, High Visibility 54160C-14850536 Fits Bray S92/93 Sizes 160 to 255 - Metric 54160C-14800536 Fits Bray S92/93 Sizes 160 to 210 - Imperial ACCESSORIES 090004-76144534 Sensor Cordset - 7/8 female straight connector to flying leads, 5-pin, 4 meters 630250-21520536 Series 63 - Valve Solenoid, NAMUR mount 3/2 or 5/2, Form B connector (DIN 43560), IP65, single 120V 50/60 Hz coil 630250-21522536 Series 63 - Valve Solenoid, NAMUR mount 3/2 or 5/2, Form B connector (DIN 43560), IP65, single 240V 50/60 Hz coil 621250-21520536 Series 62 - Valve Solenoid, NAMUR mount 3/2 or 5/2, Form B connector (DIN 43560), IP65, single 120V 50/60 Hz coil 621250-21522536 Series 62 - Valve Solenoid, NAMUR mount 3/2 or 5/2, Form B connector (DIN 43560), IP65, single 240V 50/60 Hz coil WIRING DIAGRAM CONNECTOR PINOUT All information herein is proprietary, confidential, and may not be copied or reproduced without the expressed written consent of Bray International, Inc. The technical data herein is for general information only. Product suitability should be based solely upon customer s detailed knowledge and experience with their application. Bray is a registered trademark of Bray International, Inc. 2017 Bray International. All rights reserved. TM-BC-1070_S54_0004_EU-EN_2017-11-17 S8-2 of 2

Hazardous Service DC 2 + solenoid output + terminal compartment 540102-126xx536 SENSOR FEATURES > 2-wire DC sensor with minimum off-state current > ATEX-approval for zone 2 and zone 22 > High temp, UV, salt water resistant > Rugged metal base > IP66/67/69K > High impact protection > Removable plug-in terminals > Large terminal space for easy wiring DIMENSIONS TECHNICAL DATA General specifications Switching function Output type 2 x normally open (NO) Two-wire Rated operating distance sn 2.5mm Installation Output polarity For non-flush mounting DC Assured operating distance sa 0... 2.05mm Output type Nominal ratings 2 x 2-wire Operating voltage UB 6... 30V Switching frequency f 0... 100 Hz Hysteresis H Typical 0.5 mm Reverse polarity protection Short-circuit protection Reverse polarity tolerant No Voltage drop Ud 6 V Operating current IL 4... 100mA Off-state current Ir 100... 200 µa, typical 160 µa Functional safety related parameters MTTFd 684 a Mission Time TM 20 a Diagnostic Coverage DC 0% Electrical specifications - valve circuit Voltage Current Ambient conditions 10... 32V Max. 240 ma Ambient temperature TA -40... 75 C (-40... 167 F), restriction for use in hazardous area, see instruction manual Storage temperature Mechanical specifications -40... 85 C (-40... 185 F) Connection (system side) M20 x 1.5 cable gland, ground connection + earthing screw only for wire cross-section 4mm 2, use solid wire or stranded wire + wire end ferrule Connection (valve side) Screw terminal, cable gland M20 x 1.5 Housing material Housing base Degree of protection Rugged polycarbonate (PC) + GF 10%, optimized for outdoor use Powder coated aluminum IP67; additional degree of protection IP66/IP69K with 540100-70600533 and 540100-21900533 S9-1 of 6

Hazardous Service DC 2 + solenoid output + terminal compartment 540102-126xx536 TECHNICAL DATA Terminal assembly Number 10 Connection type Type For connection of copper wires with 7 mm dismantle length. Tightening torque 0.5... 0.6 Nm Screw terminal block, pluggable Terminal capacity Conductor cross-section 0,25... 2,5 mm 2, flexible/rigid. For Multiple-wire connection: two wires of equal cross-section per 0.25...1 mm 2 Tightening torque, fastening screws Tightening torque, housing screws Tightening torque, earthing screw Tightening torque, cable gland Tightening torque, stopping plug General information Use in the hazardous area Category Compliance with standards & directives 2 Nm 1.5 Nm 1.5 Nm 4 Nm 2 Nm See instruction manuals 3G; 3D Standards EN 60947-5-2:2007 IEC 60947-5-2:2007 CCC approval VDI / VDE 3845 Approval and marking not required for products rated 36 V ASSEMBLY ACTIVATOR AND MOUNTING ASSEMBLY FEATURES > High-visibility valve position display > Protection against contamination and damage > Three level adjustable > Suitable for CW or CCW operation > 30 x 80mm actuator mounting > 30 x 130mm actuator mounting TECHNICAL DATA General specifications Housing material Activator material Protective cover material Valve status indicator Indicator adjustments Activator adjustment top level Activator adjustment bottom level Activator markings Hardware Activator targets PC PA V4A/316L Red = CLOSED Green = OPEN 5 degree increments 5 degree increments 90 degree increments 5 degree increments 316 stainless steel 303 stainless steel DIMENSIONS 30 105 83 60 207 S9-2 of 6

Hazardous Service DC 2 + solenoid output + terminal compartment 540102-126xx536 INDUCTIVE SENSOR KIT 30 x 80mm mounting pattern, adjustable activator Description Hardware Kit Part Number Bray S92/93 Sizes 63 to 128 and Series 98 NAMUR VDI/VDE 3845 Compliant mounting metric 540102-12650536 Bray S92/93 Sizes 63 to 128 imperial 540102-12600536 Series 92/93 Actuator Series 98 Actuator Part List Qty Metric (540102-12650536) Imperial (540102-12600536) 1 Sensor 540102-71104533 Sensor 540102-71104533 1 Activator assembly Activator assembly 1 Protective cover - Zone 2/22 Protective cover - Zone 2/22 2 Socket head capscrew M5X0.8X12, Stainless Steel Socket head capscrew #10-32X1/2, Stainless Steel See Series 54 IOM for full mounting details. 30 x 80mm mounting pattern, adjustable activator Description Hardware Kit Part Number Bray S92/93 Sizes 160 to 255 NAMUR VDI/VDE 3845 Compliant mounting metric 540102-12651536 Bray S92/93 Sizes 160 to 210 imperial 540102-12601536 Series 92/93 Actuator S9-3 of 6

Hazardous Service DC 2 + solenoid output + terminal compartment 540102-126xx536 Part List Qty Metric (540102-12651536) Imperial (540102-12601536) 1 Sensor 540102-71104533 Sensor 540102-71104533 1 Activator assembly Activator assembly 1 Protective cover - Zone 2/22 Protective cover - Zone 2/22 1 Mounting plate assembly Mounting plate assembly 2 Socket head capscrew M5X0.8X10, Stainless Steel Socket head capscrew #10-32X3/8, Stainless Steel See Series 54 IOM for full mounting details. WIRING DIAGRAM APPLICATION Note: The connections to this sensor are sealed with stopping plugs to protect against dirt and moisture. If not all of the connections are used in your application, then seal the remaining stopping plugs on the sensor permanently or check during initial installation and when performing regular maintenance work that the stopping plugs are secure and impermeable. If necessary, tighten the stopping plugs to a torque of 2 Nm. Shield INSTRUCTION MANUAL - GC (NA) Equipment protection level Dc (tc) Manual electrical apparatus for hazardous areas - Gas Group IIIC Device category 3G (na) For use in hazardous areas with gas, vapor and mist Certificate BR 17 CERT 1705 X CE marking ATEX marking Standards General Installation, commissioning Maintenance Special conditions Maximum operating current [IL] Maximum operating voltage [U B max] Maximum permissible ambient temperature [TUmax] at UBmax=30 V, IL =100 ma, T6 at UBmax=30V, IL=100 ma, T1... T5 at UBmax=30 V, IL =50 ma, T6 II 3G Ex na IIC T6... T1 Gc The Ex-related marking can also be printed on the enclosed label. EN 60079-0:2012+A11:2013, EN 60079-15:2010 - Protection by increased safety na. The apparatus has to be operated according to the appropriate data in the data sheet and in this instruction manual. The data stated in the data sheet are restricted by this operating instruction! The special conditions must be observed! Laws and/or regulations and standards governing the use or intended usage goal must be observed. If the Ex-related marking is printed only on the supplied label, then this must be attached in the immediate vicinity of the sensor. The sticking surface for the label must be clean and free from grease. The attached label must be legible and indel ible, including in the event of possible chemical corrosion. After opening the housing, you should check that the seal is in the correct position and is clean and intact before closing the housing again. Seal any openings on the housing not in use, using the stain less steel stopping plugs supplied. No other devices should be used to seal the open ings. The stopping plugs made of plastic must no longer be used. No changes can be made to apparatus, which are operated in hazardous areas. Repairs to these apparatus are not possible. After opening the housing, you should check that the seal is in the correct position and is clean and intact before closing the housing again. The maximum permissible load current must be restricted to the values given in the fol lowing list. High load currents and load short circuits are not permitted. The maximum permissible operating voltage UBmax is restricted to the values in the following list. Tolerances are not permitted. Depending on the load current IL, the maximum operating voltage UBmax, and the tem perature class. Details can be found in the following list. 35 C (95 F) 57 C (134.6 F) 35 C (95 F) S9-4 of 6

Hazardous Service DC 2 + solenoid output + terminal compartment 540102-126xx536 INSTRUCTION MANUAL - GC (NA) at UBmax=30 V, IL =50 ma, T1... T5 Maximum values of the valve circuit Protection from mechanical danger Protection from UV light Electrostatic charge Lead insertion Material selection accessories Plug connector 60 C (140 F) Uv = 32 V; Iv = 240 ma The sensor must not be exposed to any form of mechanical danger. If you use the protective cover 540100-70600533 and the actuator with protective cover 540100-21900533, it is ensured that the device is sufficiently protected in accordance with IEC/EN 60079-0. If protective cover becomes damaged, replace the protective cover. The sensor and the connection cable must be protected from damaging UV-radiation. This can be achieved when the sensor is used in internal areas. If you use the protective cover 540100-70600533 and the actuator with protective cover 540100-21900533, it is ensured that the device is sufficiently protected in accordance with IEC/EN 60079-0. If the protective cover becomes damaged, replace the protective cover. Electrostatic charges must be avoided on the mechanical housing components. Dangerous electrostatic charges on the mechanical housing components can be avoided by incorporating these in the equipotential bonding. Sliding contact discharges must be avoided. Avoid electrostatic charges that can cause electrostatic discharge when installing or operating the device. Information on electrostatic hazards can be found in the technical specification IEC/TS 60079-32-1. Do not attach the nameplate provided in areas where electrostatic charge can build up. If cable glands are required for the installation, then the following points must be observed. The cable glands must be certified in accordance with the application. The temperature range of the cable glands must be selected according to the applica tion. The degree of protection must not be reduced by the cable glands. Seal the housing. Use a seal that meets the requirements of the application. When selecting accessories, ensure that the material allows the temperature of the enclosure to rise to up to 70 C. The plug connector must not be withdrawn under voltage. The proximity switch is identi fied as follows: "WARNING DO NOT SEPARATE WHEN ENERGIZED. With the plug connector disconnected, soiling of the internal area must be prevented. (i.e. the area that is inaccessible when the connector is inserted). INSTRUCTION MANUAL - Dc (tc) Equipment protection level Dc (tc) Manual electrical apparatus for hazardous areas - Dust Group IIIC Device category 3D (tc) For use in hazardous areas with combustible dust Certificate BR 17 CERT 1705 X CE marking ATEX marking Standards General Installation, commissioning Maintenance Special conditions Maximum operating current [IL] Maximum operating voltage [UBmax] II 3D Ex tc IIIC T80 C Dc The Ex-related marking can also be printed on the enclosed label. EN 60079-0:2012+A11:2013, EN 60079-31:2014 - Protection by enclosure "tc" The corresponding datasheets, declarations of conformity, EC-type examination certificates, certifications, and control drawings, where applicable (see datasheets), form an integral part of this document. These documents can be found at www.bray.com. The maximum surface temperature of the device was determined without a layer of dust on the apparatus. Some of the information in this instruction manual is more specific than the information provided in the datasheet. Laws and/or regulations and standards governing the use or intended usage goal must be observed. If the Ex-related marking is printed only on the supplied label, then this must be attached in the immediate vicinity of the sensor. The sticking surface for the label must be clean and free from grease. The attached label must be legible and indelible, including in the event of possible chemical corrosion. After opening the housing, you should check that the seal is in the correct position and is clean and intact before closing the housing again. Seal any openings on the housing not in use, using the stainless steel stopping plugs supplied. No other devices should be used to seal the openings. The stopping plugs made of plastic must no longer be used. No changes can be made to apparatus, which are operated in hazardous areas. Repairs to these apparatus are not possible. After opening the housing, you should check that the seal is in the correct position and is clean and intact before closing the housing again. The maximum permissible load current must be restricted to the values given in the fol lowing list. High load currents and load short-circuits are not permitted. The maximum permissible operating voltage UBmax is restricted to the values in the following list. Tolerances are not permitted. S9-5 of 6

Hazardous Service DC 2 + solenoid output + terminal compartment 540102-126xx536 INSTRUCTION MANUAL - Dc (tc) Maximum permissible ambient temperature [TUmax] at UBmax=30 V, IL=100 ma, T80 C at UBmax=30 V, IL=50 ma, T80 C Maximum values of the valve circuit Protection from mechanical danger Protection from UV light Electrostatic charge Lead insertion Plug connector Dependant of the load current IL and the maximum operating voltage UBmax. Details can be found in the following list. 57 C (134.6 F) 60 C (140 F) U V = 32 V; I V = 240 ma The sensor must not be exposed to ANY FORM of mechanical danger. If you use the protective cover 540100-70600533 and the actuator with protective cover 540100-21900533, it is ensured that the device is sufficiently protected in accordance with IEC/ EN 60079-0. If the protective cover becomes damaged, replace the protective cover. The sensor and the connection cable must be protected from damaging UV-radiation. This can be achieved when the sensor is used in internal areas. If you use the protective cover 540100-70600533 and the actuator with protective cover 540100-21900533 it is ensured that the device is sufficiently protected in accordance with IEC/EN 60079-0. If the protective cover becomes damaged, replace the protective cover. Electrostatic charges must be avoided on the mechanical housing components. Dangerous electrostatic charges on the mechanical housing components can be avoided by incorporating these in the equipotential bonding. Sliding contact discharges must be avoided. Avoid electrostatic charges that can cause electrostatic discharge when installing or operating the device. Information on electrostatic hazards can be found in the technical specification IEC/TS 60079-32-1. Do not attach the nameplate provided in areas where electrostatic charge can build up. If cable glands are required for the installation, then the following points must be observed. The cable glands must be certified in accordance with the application. The temperature range of the cable glands must be selected according to the application. The degree of protection must not be reduced by the cable glands. Seal the housing. Use a seal that meets the requirements of the application. The plug connector must not be withdrawn under voltage. The proximity switch is identified as follows: "WARNING - DO NOT SEPARATE WHEN ENERGIZED". With the plug connector disconnected, soiling of the internal area must be prevented. (i.e. the area that is inaccessible when the connector is inserted). All information herein is proprietary, confidential, and may not be copied or reproduced without the expressed written consent of Bray International, Inc. The technical data herein is for general information only. Product suitability should be based solely upon customer s detailed knowledge and experience with their application. Bray is a registered trademark of Bray International, Inc. 2017 Bray International. All rights reserved. TM-BC-1060_S54_0102_EU-EN_2017-12-06 S9-6 of 6

Activators SERIES 54 Activators Non adjustable Activator 54-063B FEATURES > Two fixed operation surfaces offset by 180 degrees > Low resistivity plastic > Suitable for CW or CCW operation > 30 x 80mm actuator mounting > 30 x 130mm actuator mounting > Actuator mount parallel or perpendicular to pipe ASSEMBLY TECHNICAL DATA Activator material Pointer material Hardware Activator targets PA66 with carbon fiber PA6 304 stainless steel 304 stainless steel ACTIVATOR AND MOUNTING KITS 30 x 80mm mounting pattern, non adjustable activator Description Hardware Kit part number Bray S92/93 Sizes 63 to 93 and Series 98 NAMUR VDI/VDE 3845 compliant mounting Metric 54063B-14850536 Bray S92/93 Sizes 63 to 93 Imperial 54063B-14800536 Series 92/93 Actuator Series 98 Actuator DIMENSIONS 43 40 PARTS LIST Qty. Metric - 54063B-14850536 Imperial - 54063B-14800536 1 Activator Activator 1 Pinion adaptor Pinion adaptor 1 Socket head capscrew M6x1x30mm, Stainless Steel 2 Socket head capscrew M5X0.8X25mm, Stainless Steel 2 Socket head capscrew M5X0.8X40mm, Stainless Steel See Series 54 IOM for full mounting details Socket head capscrew M6x1x30mm, Stainless Steel Socket head capscrew #10-32X1.0, Stainless Steel Socket head capscrew #10-32X1.50, Stainless Steel S10-1 of 2

SERIES 54 Activators Non adjustable Activator 54-063B ACTIVATOR AND MOUNTING KITS 30 x 80mm or 30 x 130mm mounting pattern, non adjustable activator Description Hardware Kit part number Bray S92/93 Sizes 119 to 255 NAMUR VDI/VDE 3845 compliant mounting Metric 54119B-14850536 Bray S92/93 Sizes 119 to 210 Imperial 54119B-14800536 Series 92/93 Actuator (Size 119 to 128) Series 92/93 Actuator (Size 160 to 255) PARTS LIST Qty. Metric - 54063B-14850536 Imperial - 54063B-14800536 1 Activator Activator 1 Pinion adaptor Pinion adaptor 1 Series 54 sensor adaptor Series 54 sensor adaptor 1 Socket head capscrew M6X1,45MM, Stainless Steel Socket head capscrew M6X1,45MM, Stainless Steel 2 Socket head capscrew M5X0.8X25mm, Stainless Steel Socket head capscrew #10-32X1.0, Stainless Steel 2 Socket head capscrew M5X0.8X40mm, Stainless Steel Socket head capscrew #10-32X1.5, Stainless Steel 2 Socket head capscrew M5x0.8x55mm, Stainless Steel Socket head capscrew #10-32X2.25, Stainless Steel 2 Socket head capscrew M5X0.8X70mm, Stainless Steel Socket head capscrew #10-32X2.75, Stainless Steel 2 Counter sunk slotted screw M5X35,18-8 Counter sunk cross drive screw #10-32X1.5 See Series 54 IOM for full mounting details All information herein is proprietary, confidential, and may not be copied or reproduced without the expressed written consent of Bray International, Inc. The technical data herein is for general information only. Product suitability should be based solely upon customer s detailed knowledge and experience with their application. Bray is a registered trademark of Bray International, Inc. 2017 Bray International. All rights reserved. TM-BC-1072_S54_063B_ EU-EN_2017-11-16 S10-2 of 2

SERIES 54 Activators Adjustable Activator 54-063A FEATURES > Independently adjustable open and close positions > Low resistivity plastic > Three level adjustable > Suitable for CW or CCW operation > 30 x 80mm actuator mounting > 30 x 130mm actuator mounting ASSEMBLY TECHNICAL DATA Activator material Pointer material Activator adjustments Pointer adjustments Activator markings Hardware Activator targets PA66 with carbon fiber PA6 5 degree increments 5 degree increments -90 to +90 in 5 degree increments 304 stainless steel 304 stainless steel ACTIVATOR AND MOUNTING KITS 30 x 80mm mounting pattern, non adjustable activator Description Hardware Kit part number Bray S92/93 Sizes 63 to 128 and Series 98 NAMUR VDI/VDE 3845 compliant mounting Metric 54063A-14850536 Bray S92/93 Sizes 63 to 128 Imperial 54063A-14800536 Series 92/93 Actuator Series 98 Actuator DIMENSIONS 46-75 -60-45 -30-15 15 30 45 60 75 65 PARTS LIST Qty. Metric - 54063A-14850536 Imperial - 54063A-14800536 1 Activator Activator 1 Pinion adaptor Pinion adaptor 1 Socket head capscrew M6x1x30mm, Stainless Steel 2 Socket head capscrew M5X.8,12MM, Stainless Steel 2 Socket head capscrew M5X.8,15MM, Stainless Steel See Series 54 IOM for full mounting details Socket head capscrew M6x1x30mm, Stainless Steel Socket head capscrew #10-32X7/16, Stainless Steel Socket head capscrew #10-32X5/8, Stainless Steel S11-1 of 2

SERIES 54 Activators Adjustable Activator 54-063A ACTIVATOR AND MOUNTING KITS 30 x 130mm mounting pattern, non adjustable activator Description Hardware Kit part number Bray S92/93 Sizes 160 to 255 NAMUR VDI/VDE 3845 compliant mounting Metric 54160A-14850536 Bray S92/93 Sizes 160 to 210 Imperial 54160A-14800536 Series 92/93 Actuator PARTS LIST Qty. Metric - 54160A-14850536 Imperial - 54160A-14800536 1 Activator Activator 1 Pinion adaptor Pinion adaptor 1 Series 54 sensor adaptor Series 54 sensor adaptor 1 Socket head capscrew M6X1,40MM, Stainless Steel Socket head capscrew M6X1,40MM, Stainless Steel 2 Socket head capscrew M5X.8,12MM, Stainless Steel Socket head capscrew #10-32X7/16, Stainless Steel 2 Socket head capscrew M5X.8,15MM, Stainless Steel Socket head capscrew #10-32X5/8, Stainless Steel 2 Counter sunk slotted screw M5X35,18-8 Counter sunk cross drive screw #10-32X1.00 See Series 54 IOM for full mounting details All information herein is proprietary, confidential, and may not be copied or reproduced without the expressed written consent of Bray International, Inc. The technical data herein is for general information only. Product suitability should be based solely upon customer s detailed knowledge and experience with their application. Bray is a registered trademark of Bray International, Inc. 2017 Bray International. All rights reserved. TM-BC-1071_S54_063A_EU-EN_2017-11-15 S11-2 of 2

SERIES 54 Activators High Visibility & Adjustable Activator 54-063C FEATURES > High-visibility display > Suitable for CW and CCW operation > Three level adjustable activator > 30 x 80mm actuator mounting > Protection against contamination and > 30 x 130mm actuator mounting damage TECHNICAL DATA ASSEMBLY Housing material PC Activator material PA Valve status indicator Red = Closed Yellow = Open Indicator adjustments 5 degree increments Activator adjustment top level 5 degree increments Activator adjustment bottom level 90 degree increments Hardware 316 stainless steel Activator targets 303 stainless steel ACTIVATOR AND MOUNTING KITS 30 x 80mm mounting pattern, adjustable activator Description Hardware Kit part number Bray S92/93 Sizes 63 to 128 and Series 98 NAMUR VDI/VDE 3845 compliant mounting Metric 54063C-14850536 Bray S92/93 Sizes 63 to 128 Imperial 54063C-14800536 Series 92/93 Actuator Series 98 Actuator PARTS LIST Qty. Metric - 54063C-14850536 Imperial - 54063C-14800536 1 Activator assembly Activator assembly See Series 54 IOM for full mounting details S12-1 of 2