TECHNICAL INSTRUCTIONS

Similar documents
TECHNICAL INSTRUCTIONS

TECHNICAL INSTRUCTIONS

TECHNICAL INSTRUCTIONS

TECHNICAL INSTRUCTIONS

ELECTRICAL POWER GUIDE INTERNATIONAL EDITION

TECHNICAL INSTRUCTIONS

TECHNICAL SERVICE BULLETIN

XIII. Repair Parts 106

HI-FLOW FUEL RAIL. Installation Instructions for Scion tc & xb AEM Fuel Rail AN Hose adaptor

GAS-FIRED DIRECT VENT CONDENSING HOT WATER BOILER ( MBH) REPAIR PARTS MANUAL. P/N , Rev. 1.2 [02/06]

AIR/FUEL VALVES SEE DWG. PL-A-137 ITEM PART NO. DESCRIPTION LIST PRICE

Crest Heating Boilers FBN(L)

HI-FLOW FUEL RAIL. Installation Instructions for: Part Numbers , ,

WALL MOUNTED STAINLESS STEEL CONDENSING GAS BOILER PARTS, KITS & OPTIONAL ACCESSORIES

Q SERIES II GAS-FIRED DIRECT VENT CONDENSING HOT WATER BOILER

XID ENHANCEMENT SYSTEM IMPROVED EFFICIENCY AND PERFORMANCE

TECHNICAL INSTRUCTIONS

Q SERIES II GAS-FIRED DIRECT VENT CONDENSING HOT WATER BOILER

Crest Heating Boilers FBN(L)

VENTING & COMBUSTION AIR GUIDE

Installation instructions for KIT15017, KIT15018, KIT15019, and KIT15020

INSTALLATION INSTRUCTIONS NATURAL TO PROPANE CONVERSION KIT

BEFORE BEGINNING INSTALLATION

M-SERIES DIAPHRAGM COMPRESSOR REBUILD KIT

IMMERSION FIRED HOT WATER BOILER

Hydraulics. Part B, Section 1. This section covers the following unit configurations. 3700V 3800V 3900V

Heating and Gas Installations - December 2014

INSTALLATION INSTRUCTIONS, PARTS LIST AND CONFIGURATION GUIDE FOR THE CARBONATOR. Large Model No

ETP-5G & ETP-10G ECO-TECH PLUS GAS CONVECTION STEAMER PARTS AND SERVICE MANUAL

Pressure Sensor No Series

UB95M-200 Gas-Fired Direct Vent Modulating Hot Water Boiler

95M-200 GAS-FIRED DIRECT VENT MODULATING HOT WATER BOILER REPAIR PARTS MANUAL. P/N , Rev. C [09/08]

15B SERIES II. Cast Iron Gas Fired Boilers For Forced Hot Water REPAIR AND REPLACEMENT PARTS

INSTALLATION INSTRUCTIONS

PRE-INSTALLATION VENTING AND COMBUSTION AIR DESIGN GUIDE

SPARE PARTS EXPLODED VIEW GAS WALL BOILERS

GAS-FIRED, DIRECT VENT, CONDENSING, HOT WATER BOILER PARTS, KITS & OPTIONAL ACCESSORIES

Float Dynamic Steam Trap J10

FABER BURNER ROUTINE MAINTENANCE

UB Series 2 GAS-FIRED, DIRECT VENT, CONDENSING, HOT WATER BOILER. Models UB90-50 UB90-75 UB90-100

ULTRA HIGH EFFICIENCY MODELS WITH DIRECT SPARK IGNITION

Models & & 4 Air Operated Bypass Pressure Control Valves SM64501

INSTALLATION INSTRUCTIONS

USER MANUAL SELO. INNOVATION Series. Gas-Fired Hot Water Boilers. Natural Gas Modulating, Condensing Hot Water Boiler Models

FOR TECHNICAL ASSISTANCE

USER MANUAL. BENCHMARK Series Gas-Fired Boilers. Natural Gas & Propane Modulating & Condensing Hot Water Boiler Models: BMK 750 BMK 1000

Replacement Parts List

Q90-50/75/100 Series 2 Q Series 3

Mega-Rail System Installation

Troubleshooting Guide

CHALLENGER Propane to Natural Gas Instructions

Cylinder and Valve: AirHawk II Air Mask

Binks MODELS & AGITATOR DRIVE UNITS

CAUTIONS AND WARNINGS

15B SERIES II. Models 15B045FE 15B070FE 15B096FE 15B120FE 15B145FE 15B170FE 15B195FE 15B245FE 15B295FE

INSTRUCTION, HALDEX PUMP LVS KIT P/N

TurfDefender Electronic Leak Detector Kit Reelmaster 5000, 6000 and 5010 Series Traction Units

Crest Heating Boilers FBN(L)

Ultra High Efficiency Models With Direct Spark Ignition

All repair parts orders - no minimum charges. Please order with code number. All prices quoted are in U.S. dollars. All prices subject to change

Replacement Parts List. Knight Fire Tube Boilers KHB 055 thru 285 Series 100 & _ _Rev B

Models SSV-050 SSV-075 SSV-100 SSV-150 SSV-200 WALL MOUNTED GAS BOILER PARTS, KITS & OPTIONAL ACCESSORIES

Temperature Sensor Series

Q90-50/75/100 Series 4

INSTALLATION/OPERATION/MAINTENANCE INSTRUCTIONS FOR ARCHON MODELS WD2010L, WD2010, WD2010H WASHDOWN STATIONS. ARCHON Industries, Inc.

Crest Heating Boilers FBN(L)

Hydraulics. Part B, Section 1. This section covers the following unit configurations. 3400V 3500V 3700V

WALL MOUNTED GAS BOILER PARTS, KITS & OPTIONAL ACCESSORIES. Models OLSSV-050 OLSSV-075 OLSSV-100 OLSSV-150 OLSSV-200

INSTALLATION INSTRUCTIONS

Legacy Combustion Chamber Replacement Kit

Start-up Instructions

AEROMOTIVE Part # Street Rod Fuel Pump System INSTALLATION INSTRUCTIONS

UB90-50/75/100 Series 4

INSTALLATION INSTRUCTIONS

GAS UNITS KITS AND ACCESSORIES 504,605M 02/2002

USER MANUAL. BENCHMARK 2500 and Gas-Fired Boilers. Benchmark Boilers - INTERNATIONAL Installation, Operation & Maintenance Manual

advanced FLOW engineering Instruction Manual P/N: &

KC Series Gas Fired Boiler System

UNIVERSAL PUMP HANGER INSTALLATION INSTRUCTIONS

USER MANUAL BENCHMARK Gas-Fired Boiler. Benchmark 6000 Boiler Installation, Operation & Maintenance Manual

A.O. Smith Water Heater Parts Fulfillment 125 Southeast Parkway, Franklin, TN

Banks DynaFact. PYROMETER GAuGE

A.O. SMITH WATER PRODUCTS CO., INC W. 115TH STREET ALSIP, ILLINOIS Phone: Fax: Website:

Hydraulics. Part B, Section 1. This section covers the following unit configurations. 3700V

STOP CITY PRESSURE BOOSTER PUMP INSTRUCTION MANUAL

E Series CE Approved Intermittent Pilot Ignition Control

Power Direct Vent PDV T Model

Benchmark 2.0 Series Gas Fired Boiler System

UNIVERSAL PUMP HANGER INSTALLATION INSTRUCTIONS

USER MANUAL (1 of 2)

EC 200 EC 300 GE 360 GE 400 GE 600 L-S BM

2500/2700 Series Gas Convection Oven

XR8 SERIES GAS & ELECTRIC ROTATING RACK CONVECTION OVENS REPLACEMENT PARTS LIST

OPW Installation and Maintenance Instructions OPW Series Primary and Secondary Bucket Replacement Instructions

Document: 3 inch Vane Pump System-in-a-Box Assembly Instructions SPS100370

KC Series Gas Fired Water Heating System

PowerMax Diesel Upgrade For Cummins Engines

3 Inch & 4 Inch Digital Bypass Pressure Control Valves

Bettis M11 Manual Hydraulic Override System Operating Instructions for HD, T, and G Series Pneumatic and Hydraulic Actuators

Old Proportioning Pumps

Transcription:

TECHNICAL INSTRUCTIONS Benchmark 2.0LN (VFD Design) 24-Month Maintenance Kit# 58015-06 Maintenance Kit 58015-06 Contents ITEM 1 Igniter P/N GP-122435-S ITEM 2 Flame Detector P/N 66034 ITEM 3 Flame Detector Gasket P/N 81048 ITEM 4 Gas Injector Gasket P/N 81047 ITEM 5 Exhaust Manifold Seal P/N 123612 ITEM 6 Burner Gasket P/N 81101 ITEM 7 Blower Gasket P/N 81068 ITEM 8 Condensate Trap O-Ring P/N 84017 ITEM 9 Condensate Trap Orifice Gasket P/N 81092 ITEM 10 Air/Fuel Valve To Gas Train O-Ring P/N 88003 ITEM 11 LWCO Kit P/N 69126 Initial Release: DRAFT (Replaces TSB-2009-17)/fuel 02/10/2015 AERCO International, Inc. 100 Oritani Dr. Blauvelt, New York 10913 Phone: 800-526-0288 Page 1 of 18

Table of Contents 1. INTRODUCTION... 3 2. CONTENTS OF KIT 58015-06... 3 3. TOOLS, TEST EQUIPMENT & MATERIALS REQUIRED... 3 3.1 Tools... 3 3.2 Test Equipment... 3 3.3 Materials... 4 4. PRELIMINARY INSPECTION PROCEDURES... 4 5. WATERSIDE INSPECTION OF BENCHMARK 3.0 HEAT EXCHANGER... 5 6. FIRESIDE INSPECTIONS & COMPONENT REPLACEMENTS... 7 6.1 Fireside Inspection of Benchmark 3.0 Heat Exchangers... 7 6.1.1 Benchmark 2.0LN Burner Inspection... 7 6.1.2 Benchmark 2.0LN Exhaust Manifold Inspection... 10 6.2 Annual Maintenance Item Replacements...12 6.2.1 Burner Assembly Component Replacements... 12 6.2.2 External Condensate Trap Maintenance... 14 6.3 Replacing the LWCO Probe/Capacitor Assembly...15 6.4 Low Water Cutoff (LWCO) Capacitor Integrity Test...16 6.4.1 Low Water Cutoff (LWCO) - Capacitor Electrical Short Test... 16 7. FINAL REASSEMBLY AND TESTING...18 7.1 Reassembly and Set-Up Following Completion of Inspections...18 7.2 Final Testing Following Inspections...18 DISCLAIMER The information contained in this manual is subject to change without notice from AERCO International, Inc. AERCO makes no warranty of any kind with respect to this material, including, but not limited to, implied warranties of merchantability and fitness for a particular application. AERCO International is not liable for errors appearing in this manual, nor for incidental or consequential damages occurring in connection with the furnishing, performance, or use of these materials. 02/10/2015 AERCO International, Inc. 100 Oritani Dr. Blauvelt, New York 10913 Phone: 800-526-0288 Page 2 of 18

1. INTRODUCTION This provides the procedures to perform waterside and fireside inspections of the heat exchangers contained in Benchmark 2.0LN (VFD DESIGN) boilers. This 24 - Month Inspection Kit (part no. 58015-06) contains the replacement parts required to perform the waterside and fireside inspections on the Benchmark 2.0LN (VFD DESIGN) boilers. 2. CONTENTS OF KIT 58015-06 Table 1 lists the items included in the 24 Month Inspection Kit. Table 1. Benchmark 2.0LN: 24 Month Inspection Kit, Part No. 58015-06 ITEM QTY PART NO. DESCRIPTION 1 1 GP-122435-S IGNITER 2 1 66034 FLAME DETECTOR 3 1 81048 FLAME DETECTOR GASKET 4 1 81047 GAS INJECTOR GASKET 5 1 49102 EXHAUST MANIFOLD SEAL 6 2 81030 BURNER GASKETS 7 1 81068 BLOWER GASKET 8 1 84017 CONDENSATE TRAP O-RING 9 1 81092 CONDENSATE TRAP ORIFICE GASKET (.25" I.D.) 10 1 88003 O-RING 11 1 69126 LWCO / CAPACITOR ASSEMBLY KIT 3. TOOLS, TEST EQUIPMENT & MATERIALS REQUIRED The items required to perform the inspections, replacements and tests specified in this document are listed in section 3.1, 3.2 and 3.3, below. 3.1 Tools Common hand tools, plus the items listed below are required: Small Wire Brush Spark Gap Feeler Gauge 3.2 Test Equipment No test equipment is required to perform the 24 - month inspections include in this Technical Service Bulletin. However, following completion of these inspections, the Benchmark Boiler should be tested using the combustion calibration procedures provided in O & M Manual GF-123, or GF-123M. See section 7.2. 02/10/2015 AERCO International, Inc. 100 Oritani Dr. Blauvelt, New York 10913 Phone: 800-526-0288 Page 3 of 18

3.3 Materials Expendable materials required to perform the procedures described in this document are not included in the 24 -Month Inspection Kits. These materials may include such items as: Pipe joint compound Teflon tape Cleaning solvents and materials High-temperature anti-seize compound 4. PRELIMINARY INSPECTION PROCEDURES Perform the preliminary set-up and disassembly procedures in this section before performing the waterside and fireside inspections included in this document. WARNING! High voltages are used to power these boilers and so it is required that all power applied to these boilers is removed first before performing any of the procedures described in this document. Serious personal injury or death may occur if this warning is not observed. 1. At the front panel of the unit, set the ON/OFF switch on the C-More Control Panel to the OFF position. 2. Disconnect electrical power to the unit by turning off the external circuit breaker. 3. Turn off the external gas supply shutoff valve. 4. Close the water supply and return valves to the unit. 5. Refer to Figure 1 and remove the top and side panels of the unit. 6. With the top and side panels removed, the burner, heat exchangers and exhaust manifold can be accessed to prepare the boiler for the required waterside and fireside inspections described in sections 5 and 6. 02/10/2015 AERCO International, Inc. 100 Oritani Dr. Blauvelt, New York 10913 Phone: 800-526-0288 Page 4 of 18

1 TOP PANEL 1 SIDE PANEL (EACH SIDE) Figure 1. Benchmark 2.0 Low NOx (LN) Boiler (VFD Design) 5. WATERSIDE INSPECTION OF BENCHMARK 3.0 HEAT EXCHANGER Benchmark 2.0LN Models contain a single heat exchanger as shown in Figure 2. Perform the waterside inspection as follows: 1. Ensure that the preliminary set-up and disassembly procedures in section 4 have been performed to provide access to the unit s heat exchangers. 2. Allow the unit to cool prior before proceeding. 3. At the rear of the unit (Figure 2), slowly open the drain valve and drain the boiler water from both heat exchangers. 4. Open the P&T relief valve, or loosen/remove the shell sensor to allow air to enter the heat exchangers during draining. 5. After the heat exchangers have been drained, remove the 2-1/2 inch access port plugs on the right side of the primary and secondary heat exchangers, as shown in Figure 2. 6. If waterside inspection is required by your local inspector, follow the inspector's instructions. Upon satisfactory completion of the inspection, proceed to step 7. 7. Apply pipe compound to the threads of the access port plugs and replace them using a pipe wrench. 8. Close the drain valve at the rear of the boiler. 9. Close the P&T relief valve or reinstall/tighten the shell sensor removed in step 4. 10. Open the water supply and return valves to the unit and refill the heat exchangers. This completes the waterside inspection for the unit. 02/10/2015 AERCO International, Inc. 100 Oritani Dr. Blauvelt, New York 10913 Phone: 800-526-0288 Page 5 of 18

GAS INLET CONNECTION HOT WATER OUTLET CONNECTION DRAIN CONNECTION WATER INLET CONNECTION EXHAUST OUTLET Figure 2. Benchmark 2.0LN (VFD Design) - Rear View HEAT EXCHANGER HEAT EXCHANGER ACCESS PORT EXHAUST MANIFOLD Figure 3. Benchmark 2.0LN (VFD Design) - Right Side View 02/10/2015 AERCO International, Inc. 100 Oritani Dr. Blauvelt, New York 10913 Phone: 800-526-0288 Page 6 of 18

6. FIRESIDE INSPECTIONS & COMPONENT REPLACEMENTS Benchmark 2.0LN heat exchanger fireside inspections include removal of the burner and exhaust manifold assembly from the boiler. In addition, the 24 - Month Inspection Kit includes the recommended replacement parts for annual maintenance, which should also be performed at this time. Therefore, the procedures in this section are organized as follows: Fireside Inspections: Burner Inspection Exhaust Manifold Inspection Annual Maintenance Replacements: Burner Component Replacement Condensate Trap Component Replacements The procedures for the above inspections and replacements are provided in the following sections. 6.1 Fireside Inspection of Benchmark 3.0 Heat Exchangers Perform the fireside inspections of the low NOx burner and exhaust manifold using the procedures in sections 6.1.1 and 6.1.2, respectively. 6.1.1 Benchmark 2.0LN Burner Inspection The burner assembly is located at the top of the heat exchanger as shown in Figure 4. As this illustration shows, the complete burner assembly for Benchmark 2.0LN (VFD Design) also includes the blower and air/fuel valve assemblies for the unit. Figure 5 shows the burner assembly mounting details and Figure 6 shows an exploded view of the burner assembly removed from the unit. 1. Ensure that the preliminary set-up and disassembly procedures in section 4 have been completed. WARNING! THE BURNER ASSEMBLY MAY BE EXTREMELY HOT. TO AVOID BURNS, ALLOW IT TO COOL SUFFICIENTLY BEFORE ATTEMPTING TO REMOVE IT FOR INSPECTION. 2. Disconnect the lead wire from the flame detector shown in Figure 5. Unscrew and remove the flame detector. 3. Disconnect the igniter cable from the igniter (Figure 5). Unscrew and remove the igniter. 4. Remove the two (2) 10-32 screws securing the gas injector to the burner. Separate the gas injector and gasket from the burner plate. 5. Disconnect the unit wiring harness connectors from the air/fuel valve and blower motor (Figure 6). 6. Disconnect the Fast-On wire leads connected to the blower proof switch and blocked inlet switch (Figure 6). 02/10/2015 AERCO International, Inc. 100 Oritani Dr. Blauvelt, New York 10913 Phone: 800-526-0288 Page 7 of 18

7. Disconnect the gas train from the air/fuel valve flange by removing the four (4) 1/2" bolts and nuts (Figure 5). The O-ring will be replaced at reassembly with the Air/Fuel Valve to Gas Train O-ring (P/N 88003) included in the kit. 8. Disconnect the inlet air flex hose from the air/fuel valve by loosening the hose clamp (Figure 5). 9. Remove the six (6) 1/4-20 hex nuts and flat washers securing the blower to the burner plate (Figure 6). 10. Remove the blower and air/fuel valve from the burner plate by lifting straight up. Also, remove the blower gasket which will be replaced with the new gasket provided in the kit. 11. Remove the grounding screw. 12. Next, remove the eight (8) 3/8-16 nuts from the burner flange using a 9/16 wrench. NOTE The burner assembly weighs approximately 30 pounds. 13. Remove the burner assembly from burner flange by pulling straight up. 14. Remove and replace the burner gaskets. 15. Beginning with the burner assembly removed in step 13, reinstall all the components in the reverse order that they were removed. However, during this reassembly process, the following items (included in the kit) should be replaced: (a) Blower gasket (part no. 81068) (b) Gas injector gasket (part no. 81047) (c) Igniter (see section 6.2.1.1) (d) Flame detector and gasket (see section 6.2.1.2) 16. Make sure to align the staged ignition assembly, igniter and flame detector holes in the burner plate with the heat exchanger top head. 17. Check to ensure that the grounding screw is reinstalled. 18. Reattach the Air/Fuel Valve to the gas-train flange by reinstalling the four (4) 1/2" bolts and nuts (Figure 4). Replace the Air/Fuel Valve to Gas Train O-ring (P/N 88003) with the one provided in the kit. Use an alternating pattern when tightening the bolts to ensure a uniform seal. 19. Next, refer to section 6.2 and replace the igniter, flame detector and gasket using the items provided in the kit. 20. Following replacement of the igniter and flame detector, proceed to the exhaust manifold inspection procedure in section 6.1.2. 02/10/2015 AERCO International, Inc. 100 Oritani Dr. Blauvelt, New York 10913 Phone: 800-526-0288 Page 8 of 18

BLOWER BURNER PLATE AIR/FUEL VALVE SEE DETAIL A TOP VIEW BURNER PLATE FLAME DETECTOR (66034) SPARK IGNITER (GP-122435-S) STAGED IGNITION ASSEMBLY GAS INJECTOR DETAIL A Figure 4. Benchmark 2.0LN (VFD Design) - Top View BLOWER AIR/FUEL VALVE BURNER PLATE 3/8-16 NUTS (8) SPARK IGNITER (GP-122435-S) GAS INJECTOR STAGED IGNITION ASSEMBLY FLAME DETECTOR (66034) 1/2" 1/2 BOLTS & NUTS & NUTS (4 EA.) (4 AIR/FUEL PLACES) CONNECT VALVE TO GAS TRAIN AIR/FUEL VALVE TO O-RING GAS (P/N TRAIN 88003) (NOT SHOWN) Figure 5. Benchmark 2.0LN (VFD Design) Burner Assembly Removal 02/10/2015 AERCO International, Inc. 100 Oritani Dr. Blauvelt, New York 10913 Phone: 800-526-0288 Page 9 of 18

BLOWER BLOWER PROOF SWITCH BLOCKED INLET SWITCH AIR/FUEL VALVE HEX NUTS & WASHERS (6) BLOWER GASKET STAGED IGNITION ASSEMBLY FLAME DETECTOR (66034) (GP-122435-S) SPARK IGNITER BURNER GASKET (81101) BURNER PLATE FLAME DETECTOR GASKET (81048) BURNER BURNER GASKET (81101) Figure 6. Benchmark 2.0LN (VFD Design) Burner Assembly - Exploded View 6.1.2 Benchmark 2.0LN Exhaust Manifold Inspection The exhaust manifold of the Benchmark 2.0LN is installed at the rear of the unit as shown in Figure 7. Perform the following steps to remove and inspect the manifold: 1. Disconnect the flue starter section from the exhaust manifold. 2. Disconnect the condensate trap from the 1/2" NPT port on the side of the manifold. 3. Using a 3/4" socket wrench, remove the three bolts securing the exhaust manifold to the heat exchanger (Figure 7). 4. Remove the exhaust manifold and seal from the rear of the unit. 5. Remove the silicone rubber seal from the recess in the flange of the exhaust manifold. Ensure that all seal residue is removed from the flanges of the exhaust manifold and heat exchanger. 6. Inspect and clean the exhaust manifold as necessary. 7. Replace the exhaust manifold seal (part no. 123612) with the new seal provided in the 24-month maintenance kit. Install the adhesive-backed seal in the recess of the exhaust manifold flange (adhesive side down). 8. Align the exhaust manifold with the lower heat exchanger flange and secure it in place using the three (3) bolts removed in step 3. Alternately tighten the bolts to obtain a uniform seal. 02/10/2015 AERCO International, Inc. 100 Oritani Dr. Blauvelt, New York 10913 Phone: 800-526-0288 Page 10 of 18

9. Reconnect the flue starter section to the exhaust manifold. 10. Prior to reconnecting the condensate trap, perform the procedure described in section 6.2.2. 11. Reconnect the condensate trap to the 1/2" NPT condensate drain port on the exhaust manifold. HEAT EXCHANGER TO BASE SKID BOLTS (DO NOT REMOVE) EXHAUST MANIFOLD BOLTS (3) EXHAUST MANIFOLD 1 /2" NPT CONDENSATE DRAIN PORT Figure 7. Benchmark 2.0LN Exhaust Manifold Location MOUNTING ATTACHMENTS (3 PLACES) INSERT SEAL IN RECESSED AREA Figure 8. Benchmark 2.0LN Exhaust Manifold - Top View 02/10/2015 AERCO International, Inc. 100 Oritani Dr. Blauvelt, New York 10913 Phone: 800-526-0288 Page 11 of 18

6.2 Annual Maintenance Item Replacements The 24-Month Inspection Kit also contains burner assembly components and condensate trap components that should be replaced every year. 6.2.1 Burner Assembly Component Replacements The burner assembly component replacements provided in the kit include a spark igniter, flame detector and flame detector gasket. These items were previously removed from the burner during the inspection procedure in section 6.1.1. 6.2.1.1 Igniter Replacement Spark igniter, part no. GP-122435-S, is used in all Benchmark models. Replacement is accomplished as follows: 1. Using a spark gap feeler gauge, check to ensure that the spark igniter is gapped at 1/8". 2. Prior to installation, a high-temperature anti-seize compound must be applied to the to the igniter threads. 3. Refer to Figure 9 and reinstall the igniter in the location shown. Do not over-tighten. A slight snugging up is sufficient. 4. Reconnect the spark igniter cable. 6.2.1.2 Flame Detector Replacement Flame detector, part no. 66034 and gasket, part no. 81048 are used only on Benchmark Low NOx models. Replacement is accomplished as follows: 1. Refer to Figure 9 to locate the flame detector installation location. 2. Install the replacement flame detector and gasket in the location shown. Hand-tight only. 3. Reconnect the flame detector lead wire. 02/10/2015 AERCO International, Inc. 100 Oritani Dr. Blauvelt, New York 10913 Phone: 800-526-0288 Page 12 of 18

SEE DETAIL A PARTIAL TOP VIEW BURNER PLATE FLAME DETECTOR (66034) FLAME DETECTOR FLAME DETECTOR GASKET (81048) SPARK IGNITER (GP-122435-S) STAGED IGNITION ASSEMBLY GAS INJECTOR DETAIL A Figure 9. Burner Assembly Igniter & Flame Detector Locations 02/10/2015 AERCO International, Inc. 100 Oritani Dr. Blauvelt, New York 10913 Phone: 800-526-0288 Page 13 of 18

6.2.2 External Condensate Trap Maintenance The condensate trap, part no. 24060 is used with all Benchmark models. The trap should be inspected, cleaned and reassembled as follows: NOTE The condensate trap should already be disconnected from the exhaust manifold of the unit during the exhaust manifold inspection procedure. 1. Remove the connections on the inlet and outlet sides of the condensate trap shown in Figure 10. 2. Refer to Figure 10 and loosen the four (4) thumbscrews securing the cover on the condensate trap. Remove the cover. 3. Remove and discard the O-ring gasket currently installed in trap. It will be replaced with the new O-ring included in the Maintenance Kit during reassembly. 4. Remove the float (with float guide attached) from the condensate trap. 5. Remove and discard the currently installed orifice gasket from the trap. The new orifice gasket from the maintenance kit will be installed during reassembly. 6. Thoroughly clean the trap and float. Also inspect the drain piping for blockage. If the trap cannot be thoroughly cleaned, replace the condensate trap. 7. Check the condensate drain port on the exhaust manifold (Figure 11) to ensure it is clear of blockage. 8. After the above items have been inspected and thoroughly cleaned, replace the orifice gasket (use new gasket) and float in the condensate trap. Replace the O-ring (use new O-ring) and replace the trap cover. 9. Reassemble all piping and hose connections to the condensate trap inlet and outlet. Reconnect trap to condensate drain connection on the connecting manifold. Figure 10. Condensate Trap Part No. 24060 02/10/2015 AERCO International, Inc. 100 Oritani Dr. Blauvelt, New York 10913 Phone: 800-526-0288 Page 14 of 18

EXHAUST MANIFOLD CONDENSATE TRAP 1/2" NPT CONDENSATE DRAIN CONNECTION Figure 11. Exhaust Manifold Condensate Drain Location 6.3 Replacing the LWCO Probe/Capacitor Assembly The replacement LWCO probe sensor comes with a capacitor assembly attached. This procedure replaces an old probe assembly with a new probe assembly (P/N 69126). 1. Cut the shell harness wire just below the female spade connector (Figure 12). The new LWCO assembly includes a new female connector to crimp onto the shell harness wire. OLD LWCO PROBE PROBE WELL OF HOT WATER OUTLET PIPING OLD CAPACITOR (COVERED BY LARGE SHRINK TUBING) LWCO PROBE & CAPACITOR ASSEMBLY CUT OFF WIRE TO OLD LWCO ASSEMBLY HERE MALE SPADE CONNECTOR FEMALE SPADE CONN.ON THE SHELL HARNESS WIRE Figure 12: Removing Old LWCO Probe/Capacitor Assembly 2. Remove the LWCO probe from the recess well on the hot water outlet piping by unscrewing the brass coupling to which it is attached. 3. Retrieve the new LWCO probe from the kit and sparingly apply an NSF approved pipe dope to the threads of the brass coupling (Do NOT use Teflon tape) and install into the probe well vacated by the old LWCO probe. 4. The new LWCO assembly comes with a spare female connector already inserted into the male connector, and this should be crimped onto the stripped end of the shell harness wire. 02/10/2015 AERCO International, Inc. 100 Oritani Dr. Blauvelt, New York 10913 Phone: 800-526-0288 Page 15 of 18

6.4 Low Water Cutoff (LWCO) Capacitor Integrity Test The LWCO capacitor should be tested for electrical shorts after it has been replaced. The LWCO capacitor integrity test consists of two parts as described in the next two sections. The first procedure explains how to test for electrical shorting of the LWCO probe capacitor, while the second procedure instructs how to perform the standard Low Water Cutoff test using the C-More controls. Refer to Figure 13 for an illustration of the LWCO probe assembly and its typical installation. Rear Panel LWCO Probe Plastic Acorn Nut Capacitor Assembly (Covered By Large Shrink Tubing) Hot Water Outlet Pipe Connector (to Shell Harness) LWCO Probe Terminal Figure 13: LWCO Probe Location (BMK3000 Shown) 6.4.1 Low Water Cutoff (LWCO) - Capacitor Electrical Short Test This test determines if there is an electrical short between the LWCO capacitor and the heat exchanger. Perform the capacitor electrical short test as described below. 1. Turn OFF AC power to the unit. WARNING! High voltages are used to power these units and so it is required that power applied to these units is removed first before performing the procedure described in this instruction. Serious personal injury or death may occur if this warning is not observed. 2. Remove the Shell Harness Cable (male) connector from the P-5 (female) connector on the rear panel of the C-More controller (see Figure 14). 02/10/2015 AERCO International, Inc. 100 Oritani Dr. Blauvelt, New York 10913 Phone: 800-526-0288 Page 16 of 18

Unplug Shell Harness Cable from P5 Connector Figure 14: Removing Cable from P5 Connnector 3. Using an ohmmeter, connect one ohmmeter probe to the LWCO capacitor terminal on the unit shell as shown on left in Figure 15. 4. Connect the second ohmmeter probe to Pin #6 of Shell Harness Connector (removed from the C-More controller) as shown on right in Figure 15. Connect 1 st Lead to LWCO Terminal Connect 2 nd Lead to PIN #6 Ohmmeter LWCO Probe Assembly Connector 19-Pin Shell Harness Cable Connector Figure 15: Connecting Ohmmeter between LWCO Probe & Shell Harness Cable 5. Confirm that the ohmmeter does NOT read a short. 02/10/2015 AERCO International, Inc. 100 Oritani Dr. Blauvelt, New York 10913 Phone: 800-526-0288 Page 17 of 18

NOTE If the ohmmeter reads a short, the capacitor assembly needs to be replaced. See section 6.3 for replacement instructions or contact AERCO technical support for more information. 6. Remove both ohmmeter probes and reconnect the Shell Harness connector to the P5 connector on the rear of the C-More controller. 7. FINAL REASSEMBLY AND TESTING Upon completion of all waterside and fireside inspections, reassemble the unit and perform the tests specified in sections 7.1 and 7.2. 7.1 Reassembly and Set-Up Following Completion of Inspections Following completion of the all required inspections and replacements, perform the following reassembly and setup procedures: 1. Ensure that the heat exchanger has been filled and the water supply and return valves have been opened. 2. Turn ON the external circuit breaker to the unit. 3. At the front panel of the unit, set the ON/OFF switch on the C-More Control Panel to the ON position. 4. Press the LOW WATER LEVEL RESET button to reset the low water cutoff. 5. Press the CLEAR switch to reset the fault relay. This will turn off the FAULT LED and clear any displayed error message. 6. Replace the unit side and top panels. 7.2 Final Testing Following Inspections Upon completion of the inspections and replacements specified in this Technical Service Bulletin, perform the Combustion Calibration Tests specified in Chapter 4 of the O & M Manual GF-123, or GF-123M. Following successful completion of the Combustion Calibration Tests, return the Benchmark 2.0LN Boiler to service use. Change Log: --- END --- Date Description Changed By 02/10/2015 Rev-A: Initial release, converted from TSB- TSB-2009-17, replaced 66020 with 66034 per PIR 1028-3, added section 6.3 LWCO Replacement and 6.4 LWCO Capacitor Electrical Short Test Chris Blair International Inc. AERCO International, Inc., 2015 02/10/2015 AERCO International, Inc. 100 Oritani Dr. Blauvelt, New York 10913 Phone: 800-526-0288 Page 18 of 18