Process Inline Filter Medium / High Pressure PFM / PFH

Similar documents
Process screen basket filter PRFS

Process Inline Filter Protective filter PLF2-9HF

Process Inline Filter PLF1

Process Multi-Rheo Filter PMRF

Automatic back-flushing filter AutoFilt RF4

Backflushing Filter AutoFilt RF4

Backflushing Filter AutoFilt RF3

MultiRheo Filter MRF 1/2/3/4/5/6/7

Pressure Filter DF Pressure Filter for Reversible Oil Flow DFF/DFFX

LowViscosity Housing Filter LVH-F

Change-Over Pressure Filter DFDK

Pressure Filter DF...K P, DF...M P, Flange Mounted

Pressure Filter for Manifold Mounting DFP and for Reversible Flow DFPF

MultiRheo Filter MRF 1/2/3/4/5/6/7

Change-Over Inline Filter RFLD Welded Version

Return Line Filter RF

Inline filters NF NF 1350 NF 330 NF 750 NF 500 NF FILTER SPECIFICATIONS Nominal pressure

LowViscosity Housing- Coalescer Diesel LVH-CD

Inline Filters NF. Flow rates up to 3,500 l/min Pressure range 25 bar Material: Aluminium / Aluminium-Cast Iron

Suction Filter SF/SFM/SFF and Suction Filter Elements S/S..

Change-Over Inline Filter AFLD to API 614

Inline Filter LPF D A Flange-Mounted up to 280 l/min, up to 25 bar

Pressure Filters DF...M A / DF...Q E DF...MHA / DF...MHE Flow rates up to 500 l/min Pressure range up to 315 bar Material: SG Iron/ADI, Steel

Return Line Filter RF

Inline Filter RFL. Cast version Volume rates up to 1300 l/min* Pressure range 25/40 bar

Inline Filter RFLD. Change-Over. Cast Version Flow Rates up to 1300 l/min* Pressure Range 25/40/64 bar With Ball Change-Over Valve E /01.

Return Line Filter HF4R up to 450 l/min, up to 10 bar

Automatic Back-Flushing Filter for Process Technology AutoFilt RF3.

Automatic Back-Flushing Filter AutoFilt RF9.

Return line and Suction Boost Filter RKM

Change-Over Inline Filter RFLD Weld Version

Return Line Filter RFM with 4-Hole Mounting

Suction Filter SF/SFM/SFF and Suction Filter Elements S and S..

Replacement cartridge filter

Inline Filter DMG DMG 080 DMG 045 DMG FILTER SPECIFICATIONS. Temperature range -10 C to +100 C Material of filter housing

Return Line Filter RFM with 4-Hole Mounting

High Pressure Filter Pi 4230

Inline Filters for Process Technology

High Pressure Filter Pi 4230

Series RFLD Duplex In-Line Filter

Medium Pressure Filter Pi 3000

Inline Filter MFM. Flow rates up to 100 l/min Pressure range up to 280 bar Material: EN-GJS / steel E /01.04

High Pressure Filter Pi 4000

Suction Filters S8-455 SE56-560

PRESSURE FILTER Series HPV DN 25 PN 420

Low Pressure Filter Pi 2000

Duplex Filter Pi Features. Nominal pressure 40 bar (580 psi), nominal size up to 300

Filter Elements. for use in HYDAC filters* Pressure filter. Pressure filter. filter element (DIN 24550) elements. long seam weld

HYDAC Process Technology Gas Filters Product Overview

Duplex Filter Pi Features. Nominal pressure 40 bar (570 psi), nominal size 800 and 1100

Line filter Pi Features. Nominal pressure 16 bar (230 psi), nominal size 400 up to 6000

Process Technology. Product Catalogue.

Low Pressure Filter Pi 200

Duplex Filter Pi Features. Nominal pressure 10/16 bar (140/230 psi), nominal size 1250 up to 8000

Automatic filter AF 153 G

Low Pressure Filter Pi 200

Mobile Filter Unit MFU-15

Low Pressure Filter Pi 2000/Pi 2200

Medium Pressure Filter Pi 360

Filter module AF Features. MAHLE Industrialfiltration is now Filtration Group. For more information, visit

Spare parts list Inline filter FLND switchable

HYDAC Process Technology Water Filtration Product Overview

Automatic metal-edge filter AF 73 G/AF 93 G

Automatic filter AF 173 G

Duplex Pressure Filters

High Pressure Filter Pi 410

3- and 4-Way Ball Valves KH3/KH4

Block mounting filter, lateral flange-mounting possible

ES 134 ES 144 Tank top mounting Connection up to SAE 1½ Nominal flow rate up to 130 l/min

HD 790 HD 990 In-line mounting Operating pressure up to 630 bar Nominal flow rate up to l/min

HIGH PRESSURE FILTERS

Series RFL In-Line Filter

Automatic metal-edge filters AF 72 G

LS 025 LS 035 In-line mounting Connection up to G¾ / -12 SAE Nominal flow rate up to 33 l/min / 8.7 gpm

Duplex Filter Pi 3700

High Pressure Filter Pi 420

Spin-on elements. Type 80, 81 and 82. Contents. Features. RE Edition:

Low Pressure Filter Pi 2300

HD 790 HD 990 In-line mounting Operating pressure up to 630 bar / 9137 psi Nominal flow rate up to l/min / gpm

ES 074 ES 094 Tank top mounting Connection up G1¼ Nominal flow rate up to 80 l/min

Duplex Filter Pi Features. Nominal pressure 25 bar (360 psi), nominal size 800 and 1400

Suction Filter Pi 200

Medium Pressure Filter Pi 340

Low Pressure Filter Pi 230

Oil Solutions. Phone Fax Low Pressure Filter Pi 150

HIGH PRESSURE FILTERS

Duplex Filter Pi 2100

High Pressure Filters HD 044 HD 064. Flangeable Operating pressure up to 500 bar Nominal flow rate up to 105 l/min e

Automatic filter AF 112 G

Plate Heat Exchangers

Automatic filter AF 113 G

Automatic metal-edge filter AF 75 S / AF 95 S

Spare Parts List Filter NFD Change-Over Version

HIGH PRESSURE FILTERS HF4P Series Inline Filters 5000 psi up to 120 gpm

Profluid and Gap-type tube filters. Automatic filters

Low Pressure Filter Pi 1500

Return Line Filter RFM with 2-Hole Mounting

Automatic filter AF 172 G

Automatic filter AF 173 G

3/2 Way Ball Valves KHB3K

Transcription:

Process Inline Filter Medium / High Pressure PFM / PFH PFx-0 PFx-1 PFx-2 PFx-3 Specifications Connection: G 1 Q S max: 8 m 3 /h p S max: 100 bar Filtration ratings: 1 2000 µm 1. GENERAL Product description Stainless steel inline filters Separation of solid particles from fluids Filter element technology Filter elements of type SZ Filter materials: Chemicron metal fibre fleece: 1 to 20 µm Wire mesh: 25 to 250 µm Wedge wire: 50 to 2000 µm Product advantages Optimum adaptation to the application thanks to different sizes, materials and seal materials Clogging monitoring by means of a clogging indicator attached to the filter: Visual Electrical Visual-electrical Self-bleeding filter Pleated filter elements with large filter area (Chemicron metal fibre fleece and wire mesh) Renewable filter elements save costs for disposal and replacement Series PFM PFH Size Size Mounting dimension Technical data standard models Material Housing and union nut Stainless steel (austenitic Cr-Ni-Mo steel) Seal material FPM / FKM p S max [bar] T S max [ C] 0 4.4 0.4 1 4.9 0.8 PN 40 2 5.6 1.6 3 6.8 3.2 G 1 200 0 4.5 0.4 1 5.0 0.8 PN 100 2 5.7 1.6 3 6.9 3.2 Pleated Filter area [cm²] Technical specifications of filter elements Wedge wire Weight [kg] Filter materials and filtration ratings [µm] Chemicron metal fibre fleece Wire mesh Wedge wire end caps glued Wedge wire end caps welded Volume [l] Permissible differential pressure at the filter element [bar] SZ-0 676 89 SZ-1 1710 262 SZ-2 3421 552 SZ-3 6842 1133 1 3 5 10 20 25 40 60 100 150 200 250 50 100 200 300 500 1000 1500 2000 40 Max. operating temperatures lower the pressure range: PFM: T S max 200 C at p S max = 32 bar PFH: T S max 200 C at p S max = 80 bar * The selection of size depends on the level of contamination in the fluid and on the corresponding filter area load. 1

2. FUNCTION AND SPECIAL FEATURES FUNCTIONAL PRINCIPLE Flow through the filter element is from the outside to the inside The separated solids remain on the outer side of the filter element Particles being deposited during the filtration causes a loss of pressure When the maximum differential pressure has been reached, the filter element is manually exchanged or cleaned Once the filter element has been cleaned or exchanged, the filter is ready for operation again 3. CLOGGING INDICATORS* Type Clogging indicator / differential pressure monitoring Visual PVD x B.x Image Description Visual display with green / red field Automatic reset Electrical PVD x C.x Electrical signal when trigger point is reached Switch type: normally closed or normally open Automatic reset Visual-electrical PVD x D.x/-L Lamp for visual display Electrical signal (normally closed or normally open) Automatic reset * For clogging indicators, see also separate data sheet. 2

4. FILTER CALCULATION* CHECKLIST FOR FILTER CALCULATION STEP 1: REQUIRED OPERATING DATA Observe Pressure Equipment Directive PED 23/97/EC Type of operating medium Viscosity Operating pressure Operating temperature Flow rate Desired filtration rating Type of solid particles to be separated Solid particle content STEP 2: FILTER SIZING Configured on basis of pressure drop curves The flow velocity of 4 m/s at the flange inlet should not be exceeded STEP 3: DETERMINING THE FILTRATION RATING As a basic rule: as coarse as possible as fine as necessary! CIRCUIT DIAGRAM Bypass line Shut-off valve c Process inline filter Optional Inlet Outlet Shut-off valve "a" Shut-off valve "b" Scope of delivery HYDAC * Please contact our Head Office if you have any queries regarding filter calculation. 3

PRESSURE DROP CURVE (applies for water at 20 C or for media up to 15 mm 2 /s) PFM / PFH Size 0 Pressure drop [bar] Flow rate [m³/h] PFM / PFH Size 1 Pressure drop [bar] Pressure drop [bar] Flow rate [m³/h] PFM / PFH Size 2 / 3* * A longer service life can be expected for size 3. Flow rate [m³/h] 4

5. FILTER CONFIGURATION* Standard Optional Flange connections Threaded connection G 1, ISO 228 DIN EN flanges Others on request Sealing materials Differential pressure monitoring Filter elements and filter material FPM / FKM EPDM NBR FEP-coated O-ring Visual Electrical Visual-electrical M = Chemicron metal fibre fleece, D = wire mesh, S = wedge wire, end caps glued Other sealing materials on request Optionally with cooling line for T s max > 100 C MS = Chemicron metal fibre fleece with support spring, DS = wire mesh with support spring, SW = wedge wire, end caps welded Documentation Operating and maintenance instructions Manufacturer inspection certificate M in accordance with DIN EN 55350 Part 18 concerning construction and function inspection Material certificates 3.1 according to DIN EN 10204 * Other versions and customised special solutions after consultation with our Head Office. 5

6. MODEL CODE TYPE CODE FILTER HOUSING PFM / PFH Type PFM = Filter PN 40 PFH = Filter PN 100 Size 0 1 2 3 Type of connection G = threaded connection G 1 Clogging indicator version 0 = none 1 = with visual CI (PVD 2 B.1) 2 = with visual/electrical CI (PVD 2 D.0/-L..) 6 = with electrical CI (PVD 2 C.0) Permissible temperature range for clogging indicators: -20 C to +100 C Sealing material V = FPM / FKM (from -20 C to +200 C) E = EPDM (from -60 C to +150 C) N = NBR (from -30 C to +110 C) T = FEP-coated O-ring (from -20 C to +200 C) Other seals on request Modification number 0 = the latest version is always supplied currently 0 Supplementary details clogging indicator L24 = max. switching voltage depending on lamp element, lamp 24V L48 = max. switching voltage depending on lamp element, lamp 48V L110 = max. switching voltage depending on lamp element, lamp 110V L220 = max. switching voltage depending on lamp element, lamp 230V Applies for visual-electrical CI (PVD 2 D.0/-L..) Type code filter element Further supplementary details So = code number for special equipment PFM 1 G 2 V 0 L24 / FE So TYPE CODE FILTER ELEMENT SZ Filter element type Size 0 1 2 3 Filtration rating in µm Chemicron metal fibre fleece 1 / 3 / 5 / 10 / 20 Wire mesh 25 / 40 / 60 / 100 / 150 / 200 / 250 Wedge wire 50 / 100 / 200 / 300 / 500 / 1000 / 2000 Filter material M = Chemicron metal fibre fleece, MS = Chemicron metal fibre fleece with support spring, D = wire mesh, DS = wire mesh with support spring, S = wedge wire, end caps glued SW = wedge wire, end caps welded Sealing material V = FPM / FKM (from -20 C to +200 C) E = EPDM (from -60 C to +150 C) N = NBR (from -30 C to +100 C) T = FEP-coated O-ring (from -20 C to +200 C) Other seals on request SZ 1 20 M V 6

7. DIMENSIONS, FILTER Clogging indicator optional a D2 h DN1 DN2 Drain E2 D1 H2 Removal height, filter elements 55 4x M8 8 38 The dimensions quoted are approximations, given in mm. Subject to technical modifications. Size h D1 a DN1 DN2 D2 H2 E2 0 139 1 236 76 106 G 1 G 1 130 35 G 1/4 2 398 3 723 7

7. DIMENSIONS, FILTER ELEMENTS Wedge wire, filter element O-ring Pleated filter element Chemicron metal fibre fleece or wire mesh O-ring LG L Direction of flow LG L Direction of flow End caps glued/ optionally welded End caps crimped 60 Marking Model code Size L LG 0 88 96 1 185 193 2 347 355 3 672 680 61 The dimensions quoted are approximations, given in mm. Subject to technical modifications. 8. DIMENSIONS, CLOGGING INDICATORS* Visual clogging indicator Visual-electrical clogging indicator Electrical clogging indicator 64 110 106 Marking Model code * For clogging indicators, see also separate data sheet. 8

NOTE The information in this brochure relates to the operating conditions and applications described. For applications or operating conditions not described, please contact the relevant technical department. Subject to technical modifications. Process Technology GmbH Am Wrangelflöz 1 D-66538 Neunkirchen Tel.: +49 (0)6897-509-1241 Fax: +49 (0)6897-509-1278 Internet: www.hydac.com E-mail: prozess-technik@hydac.com 9