P O B o x S t. L o u i s, M O P h o n e : ( ) ~ E m a i l : w m h u I t a o l.

Similar documents
Whitepapers. ESD Design Concerns in Automated Assembly Equipment by Donn G. Bellmore, Universal Instruments

Installation Operation Maintenance

Thank you for purchasing a Borla Performance Cat-Back Exhaust System.

Keystone Series GR resilient seated butterfly valves GRW/GRL Installation and operation manual

Product Manual (Revision A) Original Instructions. EG-3P Actuator Installation on Detroit Diesel V-149 Engine. Kit Installation Manual

Thank you for purchasing a Borla Performance Cat-Back Exhaust System.

ESD Tests on Protektive Pak Versus Coated ESD Boxes

Orifice Flange Union Assembly and Orifice Run Installation and Operation Manual

Thank you for purchasing a Borla Performance Stainless Steel Header.

Bore (B) Pitch Diam. Drilling Template Flanges (1) Diam of Diam of. Groove. Neck D X G A Raised Face Raised Face P Raised face

Installation, Operation and Maintenance Guide II NIBCO High Performance Butterfly Valves Series 6822 and 7822

Header Installation for Ford Mustang GT, PN-17290* Adaptor Pipe PN-60566*

Instructions for Porsche PN s * and

How You Benefit From The KC Sealing System A New Definition Of Leaky Flanged Joints Comparison Of Flanged Joint After Bolt-Up...

Ground Fault Cable Retractor GR1000L Service Manual

AN EXPLANATION OF CIRCUITS CARTER YH HORIZONTAL CLIMATIC CONTROL CARBURETER

Priming Systems Installation Instructions

TESLA MODEL S REAR UNDER SPOILER & DIFFUSER SYSTEM

Thank you for purchasing a Borla Performance Cat-Back Exhaust System.

INSTALLATION INSTRUCTIONS

SITRANS AS 100. Instruction Manual September 2001 ITRANS AS 100

MEMORY SEAL BALL VALVES MAINTENANCE MANUAL 2 12, Class 150 & 300, Regular Port, Flanged Unibody

KEYSTONE OPTISEAL F14/16-15/17 AND BREWSEAL BUTTERFLY VALVES INSTALLATION AND MAINTENANCE INSTRUCTIONS

Installation Vertical Pump: Installation 'CM' and 'CDM' Style: Operation:

Thank you for purchasing a Borla Performance Cat-Back Exhaust System.

ORDERING: Specify size, figure number, description, nominal pipe size or special O.D. and C-to-C dimension. C - C LOAD lb.

25-kV Apparatus Bushings A Series (clamp-in) for Elbow to Air-Insulated Service 200 Amp and 600 Amp

Recommended BFV Installation, Maintenance & Repair Procedures Ultraflo 300 & 400 Series Valves

The Use of Conduction Tracers Vs Bare Tracers Metric Version

Safer and Easier with Conductive Piping. Making Fuel Flow Safely.

Thank you for purchasing a Borla Performance Cat-Back Exhaust System.

Installation, Operation, and Maintenance Manual

2.- HANDLING OF VALVES BEFORE ASSEMBLY 3.- FITTING THE VALVE TO THE REST OF THE ASSEMBLY 5.- PERIODICAL INSPECTION OF THE VALVE AND MAINTENANCE

ELECRAFT KX3 Application Note

Thank you for purchasing a Borla Performance Cat-Back Exhaust System.

[DRAFT VERSION] For use for company in Europe who will place the product on the market. Please amend which necessary. Document No:

6.7L Cummins EGR Delete

The H-MAC Heavy Metal Articulating Chassis Construction Guide

DEMCO Resilient-Seated Butterfly Valve

Product Manual (Revision G) Original Instructions. Auxiliary Devices for UG-40 Governors used in Marine Service.

PRXB EXHAUST BRAKE HIGH PERFORMANCE

Thank you for purchasing a Borla Performance Cat-Back Exhaust System.

Thank you for purchasing a Borla Performance Cat-Back Exhaust System.

Towing and Road Service Guide For 2010 Lexus GX460. Quality and Education Services AAA Automotive 1000 AAA Drive Heathrow, FL 32746

Installation Operation Maintenance. LSSN Butterfly Valve AGA Approved 50MM - 150MM. QAD#IM6055.REVA

ELECRAFT K3 HIGH-PERFORMANCE METER TRANSCEIVER INSTALLING CRYSTAL I.F. FILTERS. Rev A, October 15, 2007

SAE FLANGES V C. Specialists in VESCOR. Hydraulic Reservoirs and Accessories

FULL FLOATER HUB KIT INSTRUCTION MANUAL

INSTALLATION INSTRUCTIONS

INSTALLATION, OPERATION, MAINTENANCE MANUAL FOR MANUALLY OPERATED STOP CHECK VALVE

Header Installation for Ford Mustang GT, PN-17290* Adaptor Pipe PN-60566**

GP125S STAINLESS HEADER

BulletProofDiesel.com

ORIFICE PLATES, FLANGES FLOW NOZZLES, VENTURI TUBES AND ACCESSORIES

ANDERSON GREENWOOD SERIES 500 PILOT OPERATED SAFETY RELIEF VALVES INSTALLATION AND MAINTENANCE INSTRUCTIONS

Thank you for purchasing a Borla Performance Cat-Back Exhaust System.

Thank you for purchasing a Borla Performance Cat-Back Exhaust System.

CABINET - CURRENT TRANSFORMER Indoor - Outdoor 240 Volts Amperes Maximum

NOTE: Visit our website at for video repair procedures, under the Tools section.

ELECTRIC ACTUATOR AND CONTROLLER FOR AKRON BUTTERFLY VALVES INSTALLATION INSTRUCTIONS

PTFE Lined Pipe and Fittings

Fueltec Models 950AW & 955SS Mobile Fuel Tank Cleaning Systems

GF Piping Systems. SurTap System Operation with VersaTap Fittings Manual

Section 8 AMERICAN. Flanged Pipe

Static Discharge Ignition of Combustible Atmospheres

Current Ford F150 Race Series R Rear Bumper Installation Instructions

Appendix D Outline Dimensions

Static Electricity Hazards and Control

Steel pipe is almost always supported on flotation cells to keep it above water where it is accessible for repair, lengthening or shortening.

Installation Manual v1.0: MST Turbo Kit ( ) 5.9L Dodge. Please read all instructions before installation.

Vickers 45. VMQ Series 30 Vane Pumps. Fixed Displacement, For Industrial and Mobile Applications (4.188)

Thank you for purchasing a Borla Performance Cat-Back Exhaust System.

DEMCO DEMCO RESILIENT SEATED BUTTERFLY VALVE. Installation, Operation and Maintenance Manual D I S T R I B U T E D V A L V E S DEM-RSBV-IOM

AG2000 IRRIGATION MAGMETER INSTRUCTIONS

Thank you for purchasing a Borla Performance Cat-Back Exhaust System.

INSPECTION & MAINTENANCE BULLETIN ARI Plug Type Angle Valves

F low L ine 72/73 Wafer & Lug Style Sizes 2-24

Thank you for purchasing a Borla Performance Cat-Back Exhaust System.

E E VDC COOLEDGE TILE INTERIOR INSTALLATION INSTRUCTIONS. Caution: Observe precautions for handling electrostatic sensitive devices.

INSPECTION & MAINTENANCE BULLETIN ARI 1301/1302 1" Plug Type Angle Valves

NYL Resilient Seated Butterfly Valves Operation and Maintenance Instructions

Pipe fi ttings MUST be installed by a certifi ed welder only. Signet will not assume liability of any kind for improper fi tting installations.

CompoSeal butterfly valves, wafer style Installation & Maintenance Instructions

Thank you for purchasing a Borla Performance Cat-Back Exhaust System.

THY-388Y / THY-388Y-S CHEVY PICKUP, 92½-95 PICKUP, SUBURBAN PARTS INCLUDED TOOLS REQUIRED HARDWARE INCLUDED WARRANTY NOTES

Low-Cost Pipeline Flow Meter

DEMCO Resilient Seated Butterfly Valve

Kit No KIT FITS 2" & 4" DROPS

HIGH PERFORMANCE BUTTERFLY VALVE MODEL HP300 SERIES

Diaphragm Valves Type 15

INSTALL MANUAL D o d g e 1 2 v 6 B T A PLEASE READ ALL INSTRUCTIONS BEFORE INSTALLATION.

AUXILIARY COMPONENTS

INSTRUCTIONS, (FORD) SUPER DUTY INSTALLATION KIT (C2 PICKUP LIFTGATES)

Lab 4: Robot Assembly

Powerful + Efficient + Reliable

Table of Contents. Introduction. Description. Greater Total System Efficiency. Improved Design. Easy Installation and Maintenance

Coro-Vane Maintenance CP471. and Disassembly

MODELS JG43, JG63, JG83 JG44, JG64, JG84

EGR Delete Kit Dodge 6.7L Cummins

INSTALL INSTRUCTIONS DC C-EV. Installation Instructions: DC C-EV.

Transcription:

P O B o x 3 11 5 4 S t. L o u i s, M O 6 3 1 3 1-0 1 5 4 P h o n e : ( 3 1 4 ) 9 6 6-8 9 1 9 ~ E m a i l : w m h u I t t @ a o l. c o m Triboelectric Charge Generation with regard to Partially and Fully Fluoronated Lined Pipe by William M. Huitt (Written on April 15, 2004 in preparation for a discussion that took place in response to an issue on lined pipe corrosion) Abstract There is a heightened degree of concern with both currently operating facilities and future facility design with regard to Internal and External Triboelectric Charge Generation and Accumulation (static electricity) as it relates to Lined Pipe. This paper will address those concerns, on a non-specific basis, while attempting to suggest some possible corrective actions/solutions to both installed systems as well as possible inclusions to a Company s pipe specifications for future installations. Clarification Internal and external charge accumulation, known as static electricity, or more technically known, as triboelectric charge accumulation, is the result of charge generation unable to dissipate. If the charge generation is allowed to dissipate to ground then there is no problem. However, if the charge generation cannot dissipate and is allowed to accumulate, it now becomes a potential problem by creating an Electrostatic Discharge (ESD). With regard to thermoplastic lined pipe there are two issues to be considered: External Charge Accumulation (ECA) and Internal Charge Accumulation (ICA). External Charge Accumulation ECA is a concern with lined pipe due to the potential loss in spool-to-spool continuity. The concern is not due to the liner, but is instead due to other factors related to lined pipe. This potential loss of integral continuity is the result of the prime paint coat that is applied by the manufacture. When pipe spools, lined or un-lined, are joined by flanges using non-metallic gaskets the only thing that completes the Spool-to-spool continuity is the bolting. Pipe generally does not come with a prime coat of paint, however lined pipe does. Since flange bolts are used to complete continuity from spool to spool the installer has to make certain, when installing lined pipe, that the bolts, at least one of the four or more bolts, has penetrated the primer and made contact with bare metal. This was achieved in the past by using star washers on at least one flange bolt while assuming possible bare metal contact with the other bolts allowing the washers, as they were tightened, to scrape away the prime coat so that contact was made with the bare metal of the flange. With improved prime coat material this is no longer an assurance. If continuity from spool to spool is not achieved any charge generation resulting from an internal or an external source cannot readily dissipate to ground. The voltage in triboelectric charge generation will build until it is strong enough to jump to the closest grounded object creating an undesired spark of electricity in doing this (Electrostatic Discharge). Internal Charge Accumulation ICA, with regard to pipe, is unique to thermoplastic lined pipe and solid thermoplastic pipe. Without being impregnated with a conductive material, thermoplastics are not good conductors of electricity. PTFE (Polytetrafluoroethylene), as an example, used as a pipe liner, has a high (>10 16 Ohms/Square), resistivity factor. This is a relatively high resistance to conductivity. Which means that any charge created internally to the pipe cannot readily be conducted away to ground by way of the PTFE liner. Instead the charge will be allowed to build until it exceeds its total dielectric strength and burns a pinhole in the liner to the internal metal wall of the casement pipe. It isn t charge generation itself that is the problem, it s the charge accumulation. When the rate of charge generation is greater than the rate of charge relaxation (the ability of material to conduct away the generated charge), charge accumulation occurs. 1

The dielectric strength of PTFE is 450 to 500 volts/mil. This means that for every 0.001 of PTFE liner 450 volts of triboelectric charge will be required to penetrate the liner. For a 2 pipeline with a 0.130 thick liner this translates into 58500 volts of triboelectric charge to burn through the liner thickness. When this occurs two additional problems (time bombs) are created: 1. Corrosive fluid is now corroding the metal pipe wall, which at some point, depending on rate of corrosion, will fail locally causing fluid to leak to the environment, and 2. The initial charge that burned through the liner is now charging the outer metal pipe, which, if continuity has not been achieved for the outer pipe will simply continue to build until, at some point, it will have accumulated enough energy to jump to the closest grounding point causing a spark. Corrective Action External Charge Generation Aside from no paint or a conductive prime paint, the current ready-made solution to the external continuity problem is the addition of stud bolts located in close proximity to flanges on both pipe spools and fittings (see Fig. 1 below). These studs can be applied at the factory or in the field. At each flange joint a grounding strap (jumper) is then attached and affixed with a nut to the stud on one spool, extended over the flange joint and attached to a stud on the connecting spool completing continuity throughout the chain of connecting spools and fittings. Figure 1 Grounding Lug Location Another method of creating continuity at flange joints, as suggested by this paper, while being less obtrusive and more integral is described as follows and represented in Fig. 2: Figure 2 Continuity Flange Plate 2

Referring to Fig. 2 flanges would be purchased pre-drilled and tapped in the center of the outer edge of the flange between the backside of the flange and the face side of the flange. The drilled and tapped hole in each flange will need to be centered between boltholes so that they line up after the flange bolts are installed. The tapped hole is 1/4 dia. x 3/8 deep. After a flange set is installed and fully bolted the Continuity Plate (Fig. 2) can be installed using two 1/4 x1/2 long hex head screws and two lock washers. The Continuity Plate has two 0.312 slotted boltholes allowing for misalignment and movement. The entire continuity plate assembly is relatively simple to install, unobtrusive and establishes integral contact throughout the pipeline. Internal Charge Generation One of the first options in preventing Internal Charge Accumulation is by minimizing charge generation. This can be done by adjusting the flow velocity relative to the liquid s conductivity. To minimize design impact, cost and even schedule impact on a project this needs to be evaluated early in the project due to the possibility of line size increase. To retard charge generation by reducing flow velocities British Standard (BS) suggests the following in Table 1 per BS 5958: TABLE 1 - RECOMMENDED VELOCITIES BS 5958 Recommended Flow Liquid Conductivity Velocity Greater than 1000 ps/m No restriction 50 1000 ps/m Less than 7 m/s Less than 50 ps/m ps/m (picosiemens/meter) Less than 1 m/s The entire continuity plate assembly is relatively simple to install, unobtrusive and establishes integral contact with the pipeline. If velocity reduction is not an option, or further safeguards against charge accumulation are warranted then a mechanical solution to provide a path to ground for Internal Charge Generation may be called for. One method for conducting charge accumulation from the interior of the pipe to ground is indicated in Figures 3 & 4. What is shown is an orifice plate made of conductive (static dissipative) material that is compatible with the fluid service. The orifice itself is off center to the OD of the plate. With the ID of the orifice plate tangent to the invert of the pipe it allows the piping to drain in horizontal runs. The tab portion of the plate extends beyond the flange OD. On the tab is a bolt hole for attaching the modified Continuity Flange Plate. The plate is designed to come in contact with the interior surface of the liner wall as well as protrude into the flowing fluid providing a conduit for internally generated charge. Continuity is achieved by attaching the plate to the flange OD that is in contact with the piping, which is, in turn, grounded through equipment. 3

Conclusion and Recommendations It is difficult to pre-determine, in a lab environment, what fluid services and systems will be candidates for charge accumulation prevention and Electrostatic Discharge protection. The simplest and most conservative 4

answer to that is to assume that all services and systems are susceptible. In saying that, we then have to declare that the pipe specifications need to reflect a global resolution that will affect all installations. With regard to External Charge Accumulation, the recommendation for future installations with the least impact would be to specify pipe with no prime coat, or a prime coat using a conductive paint, available from some of the manufacturers. The un-primed pipe would be painted the same as the unlined carbon steel pipe after installation. This would provide spool-to-spool external continuity, the same as unlined pipe. For existing installations either the studs or the continuity plate installation would work. It can also be suggested that the continuity plates can be tacked on rather than drilling and tapping each flange. This will require grinding out the weld on at least one flange for removal. If that poses no problem then it is a simpler method. For dissipating internal charge generation the orifice plate, as shown in Figures 3 & 4, is the only recommendation. END OF PAPER 5