Soliphant II FTM30(D/S)/31(D/S)/32(D/S)

Similar documents
Level Limit Switch soliphant II FTM 30 (D/S), FTM 31 (D/S), FTM 32 (D/S)

Soliphant T FTM260. Technical Information. Level limit switch Cost-effective vibration limit switch for fine-grained solids

Level Limit Switch soliphant FTM 930/931/932/ Z

Level Limit Switch liquiphant FTL 365 / FTL 366

Level Probes multicap T DC 12 TE multicap T DC 11/16/21/26 TEN/TES

Level Probes multicap T DC 12 TA multicap T DC 11/16/21/26 TAN/TAS

Vibration Limit Switch liquiphant M FTL 51 C

Level Limit Switch liquiphant FTL 360 / FTL 361

Level Probes multicap DC 11/16/21/26 EN multicap DC 11/16/21/26 ES

Level Probe multicap DC 16

Soliswitch FTE20. Technical Information. Point level switch for granular solids

Soliswitch FTE30. Technical Information

Electromagnetic Flow Monitor magphant

Rod probe 11375Z. Technical Information. Conductive level limit detection Partially insulated rod probe for use in conductive liquids

Solicap M FTI55, FTI56

DIAMOND POINT VIBRATING PROBES

Overview. Specifications. Applications

Level instruments. Continuous level measurement - Capacitance transmitters SITRANS LC300. 5/262 Siemens FI Overview.

NIVOCONT R VIBRATING ROD LEVEL SWITCHES

Magnetic float switch For vertical installation Model FLS (models with Ex approval: 60, AL-ADF)

Level Measurement. Point level measurement Capacitance switches. Pointek CLS200 Standard. icenta Controls Ltd

Level Measurement. Point level measurement Capacitance switches. Pointek CLS200 Standard. 4/18 Siemens FI Overview.

OPTISWITCH 4000/5000. Vibration level switches for liquids

Level limit switch Series RF 3000 Selection list

Operating Instructions. VEGASWING 61, 63 with oscillator SW E60N (EX)

Point level measurement Capacitance switches

Level Measurement Point level measurement - RF Capacitance switches

Level Measurement. Point level measurement Capacitance switches. Pointek CLS300 Standard. 5/42 Siemens FI Overview.

Actuators & Positioners Electro-Pneumatic Converters I/P Signal Converters - TEIP 11 Model without Booster Stage

Series 3730 Electropneumatic Positioner Type

Continuous level measuring system NB 4000 Selection list

Ultrasonic Measurement prosonic FDU 80 86

P U L S A R point 210

Magnetic-inductive flow meter for hazardous areas

Continuous level measuring system. LevelMax. Selection Guide. Overview 2

Field IT Actuators & Positioners Electro-Pneumatic Converters I/P Signal Converters Standard Model with Booster Stage

Vibrating Level Switches for Liquids & Solids HYC-VLS02 Elect. Iss. 02 SIL 2 APPROVED VIBRATING LEVEL SWITCHES FOR LIQUIDS AND SOLIDS

NIVOSWITCH R-400/R-500

CAPACITIVE LEVEL SWITCHES. Capacitive switch catalogue HYC-CSC01 Elect. Iss. 01

Continuous level measuring system NB 3000 Selection list. Overview

Level limit switch Series CN 4000 Selection list. Specifications 2. Applications 4

Metal tube flowmeters. Series SC250. Metal Tube Flow Meters. Series SC250. Variable area flowmeter for liquids, gases and steam

Sensor boxes SRBE Key features and product range overview

CVR-625. Compact Vibrating Rod Instruction Manual

INLINE Flow sensor for hazardous area II 1 G/D - II 2 D - II 3 GD - I M1

Oscillating piston flowmeters Series COVOL Positive displacement flowmeter for liquids

FS10. Vertically-Mounted Magnetic Float Level Sensor. Level Measurement and Monitoring. reliable and robust, heavy-duty technology

KINAX SR 709 Transmitter for Position Feedback

Level Measurement Point level measurement - RF Capacitance switches

Continuous level measuring system NB 3000 Selection list

A Higher Level of Performance. Data Sheet. Centurion. Guided Radar. CGR Series. For more information, please visit >

Level Measurement. Continuous level measurement - Capacitance transmitters SITRANS LC500. 5/282 Siemens FI Overview.

XMP ci. Process Pressure Transmitter with HART -communication. Ceramic Sensor. accuracy according to IEC 60770: 0.1 % FSO.

Liquicap M FTI51, FTI52

p Additional dimensions see section dimensions.

Mobrey dry products level measurement and control

Type 2511/12. Type Type 2030 Cable plug. ASI cable plug. Dosing control. General technical data Orifice Type 6518

DMP 333. Industrial Pressure Transmitter For High Pressure. Stainless Steel Sensor

Level measurement Guided microwave Product Information VEGAFLEX ma/hart. Level Switching Pressure

TUNING FORK LEVEL WORKING PRINCIPLE APPLICATION. Solid Level Detection FEATURE. For Liquid: * Water & Solutions * General Purpose Solvent * Petroleum

Turbine flowmeters Series TM

Indumax P CLS50. Technical Information. Highly resistant, inductive conductivity sensor for standard, hazardous and high-temperature applications

Intrinsically safe presure transmitters for hazardous environments Type MBS 4201, MBS 4251, MBS 4701 and MBS Technical brochure

3/2-, 5/2- and 5/3-way Solenoid Valves for process pneumatics

KINAX SR 709 Transmitter for position feedback

Level Sensors and Switches Guided Radar (TDR) Radar Wave Level Sensors Ultrasonic Level Sensors Rotating Paddle Level Switches Vibrating Fork Level

System 6000 Electropneumatic Converter for Direct Current Signals Type 6116 i/p Converter

process measurement solutions The dry products level control catalogue

Level Measurement Point level measurement - RF Capacitance switches

Electronic Limit Switch Type

k Applications Bourdon tube pressure gauge with switch contacts For the process industry, NS 100 and 160 Models PGS and PGS23.

Thermowell for temperature sensors omnigrad M TW 13

Type Electronic Limit Switch

T 3965 EN Type 3965 Solenoid Valve Island To control pneumatic actuators

3RG4 BERO Inductive Proximity Switches



The Mobrey product range provides reliable point level detection in a variety of dry solid applications


DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor

3/2-, 5/2- and 5/3-way Solenoid Valves for process pneumatics

BGN. All Metal Variable Area Flow Meter. Technical Data Sheet

Differential Pressure Gauges Cryo Gauge Model , Cu-alloy Model , Stainless Steel Series

SATRON VVFe Pressure Transmitter

JUMO dtrans p20. Process pressure transmitter. Type Brief description. Key features. Block diagram

Flow switches Series AD/VH

BFS-10-O G1/4: BFS-10-O G1/2: BFS-10-O G1: Contact rating: BFS-10-O G1/4

Metal tube variable area flowmeter for gases, liquids and steam

A Higher Level of Performance. Data Sheet. Centurion. Guided Radar. CGR Series. For more information, please visit >

Electromagnetic Flow Monitor magphant

Solenoid Valves Type 3963

Continuous level measurement Capacitance transmitters

Omnigrad TA20, TA21. Technical Information. Temperature Measuring Technology Terminal heads for mounting on thermowells of resistance thermometers

Design and application


BM 26 BASIC/ADVANCED Technical Datasheet

Level limit switch Series RN 3000 / 6000 Selection list

Technical Datasheet P-30/P-31. Standard transmitter.

Series V2001 Valves Type 3531 Globe Valve for Heat Transfer Oil with pneumatic or electric actuator

DMP 331 DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor. Pressure Transmitter. Industrial

Transcription:

Technical Information Soliphant II FTM0(D/S)/(D/S)/2(D/S) Level Limit Switch Universal vibration limit switch for fine-grained bulk solids Suitable for dust explosion hazardous areas Application Soliphant is a rugged limit switch for silos containing powdered or fine-grained solids, including those with very low bulk densities. The various versions ensure it can be used in a wide range of applications, including dust explosion areas and foodstuffs. FTM0 (left): compact version for mounting at any orientation; e.g. with aluminium housing (T) with separate connection compartment FTM (middle): with extension tube max. 4 m for mounting at any orientation; e.g. with aluminium housing (F6) FTM2 (right): with rope max. 20 m for mounting from above; e.g. with aluminium housing (F6) Typical applications: grain, flour, milk powder, cocoa, sugar, animal feed, washing powders, dyes, chalk, plaster, cement, plastic granules Your Benefits No calibration: simple commissioning Insensitive to build-up: maintenance-free operation No moving parts: no wear, long operating life Various electronic inserts: optimum adaptation to the plant control system Plastic housing F0 with transparent cover: switching status seen externally, simple control Aluminium housing T with separate connection compartment: also available with explosion protection to EEx de TI249F/00/en

Table of contents Measuring System.............................................................................. Function.................................... 4.................................................. 4 Summary of Mechanical and Electrical Versions..... 4 Applications according to certificate....................... 4 Plug-in electronic inserts............................... 5 Housing............................................ 5 Process Connections................................... 6 Sensor versions....................................... 6 Dimensions................................. 6.................................................. 6 Installation.................................. 8 Soliphant FTM0..................................... 8 Soliphant FTM, FTM2.............................. 9 Electrical Connection......................... 0................................................. 0 Technical Data.............................. 2 General Specifications................................. 2 Application......................................... 2 Operation and System Design........................... 2 Input............................................. 2 Output............................................ Measuring Accuracy.................................. Operating Conditions................................. Construction....................................... 4 Display and User Interface............................. 5 Power supply....................................... 5 Certificates and Approvals............................. 5 Ordering.......................................... 5 Accessories................................ 6 Seperate Housing HTM0E............................ 6 Rope Shortening Set.................................. 6 Protective Hood..................................... 6 Sliding Sleeve....................................... 7 Product Structure............................ 7 Product Structure.................................... 7 2 Endress+Hauser

Measuring System Soliphant FTM0/ or FTM2 with the integrated electronic insert FEM is a compact limit switch to which miniature contactors, magnetic valves and programmable logic controllers (PLCs) can be directly connected. It can be used in safe or in explosion hazardous areas. Soliphant FTM0D/D/2D has in addition explosion protection to EEx de. Soliphant FTM0S/S/2S has explosion protection to EEx i and requires a separate switching unit Nivotester FTL mounted outside the explosion hazardous area. e.g. FTM with FEM e.g. FTM2 with FEM2 U~ + A B e.g. FTM0 with FEM4 C I PFM t D e.g. FTM0S with FEM7 explosion hazardous area Nivotester FTL U A) Compact limit switch for two-wire AC power supply B) Compact limit switch for three-wire DC power supply C) Compact limit switch for universal power supply D) Limit switch as intrinsically safe version with remote switching unit L00-FTMxxxx-4-05-xx-en-00 Endress+Hauser

Function The symmetrical vibrating fork is excited to its resonant frequency. When the fork is covered by material, the vibrations are damped. The change in amplitude is registered by the electronics which activate either an electronic switch or a relay. Soliphant is especially sensitive at the tip of the fork, making it ideal for the limit detection of materials which have a very low bulk density. In contrast, the base of the fork is very insensitive and is therefore unaffected by material build-up on the vessel walls. Soliphant can be operated in both minimum or maximum fail-safe mode, i.e. the electronic switch opens or the relay de-energises when the minimum or maximum level is reached, on fault or on power failure. Electronic inserts Level Fail-safe mode FEM FEM4 FEM2 FEM4 FEM44 FEM5 FEM45 FEM7 50 Hz Max. 2 L+ + 4 5 2 7 8 9 50 Hz 2 L+ 4 5 2 7 8 9 50 Hz Min. 2 L+ + 4 5 2 7 8 9 50 Hz 2 L+ 4 5 2 7 8 9 U 2 L+ 4 5 2 7 8 9 L00-FTMxxxx-05-06-xx-en-00 The function of the electronic switch or relay depends on the level and fail-safe mode. The electronic insert FEM7 changes the frequency of the PFM signal causing the Nivotester FTL to switch accordingly. Summary of Mechanical and Electrical Versions Applications according to certificate FTM.. Standard application Dust-Ex area FTM..D Standard application Gas-Ex area Dust-Ex area Ignition protection EEx de CSA, FM: XP FTM..S Standard application Dust-Ex area Ignition protection EEx i CSA, FM: IS 4 Endress+Hauser

ENDRESS + HAUSER Soliphant II FTM0(D/S), FTM(D/S), FTM2(D/S) Plug-in electronic inserts simple to replace with another electronic insert without recalibrating Two-wire AC power supply (thyristor) FEM for FTM0, FTM0D, FTM, FTM2; FEM4 for FTMD, FTM2D, FTM2 dust-ex Three-wire DC power supply (transistor, PNP) FEM2 for FTM0, FTM0D, FTM, FTM2 (not for FTM2 dust-ex) L00-FTMxxxx-0-05-xx-xx-00 Universal power supply (relay, potential-free changeover contact) FEM4 for FTM0, FTM0D, FTM, FTM2; FEM44 for FTMD, FTM2D, FTM2 dust-ex L00-FTMxxxx-0-05-xx-xx-002 Universal power supply (relay, 2 potential-free changeover contacts) FEM5 for FTM0, FTM0D, FTM, FTM2 FEM45 for FTMD, FTM2D, FTM2 dust-ex (not for EEx de) L00-FTMxxxx-0-05-xx-xx-00 Intrinsically safe signal transmission along two-wire cabling to remote switching unit Nivotester FEM7 for FTM0S, FTMS, FTM2S L00-FTMxxxx-0-05-xx-xx-004 PFM L00-FTMxxxx-0-05-xx-xx-005 Housing all with IP66 protection and a wide range of cable entries; with high cover for FEM5/45 Aluminium housing F6 for FTM.. and FTM..S Steel housing F8 for FTM.. and FTM..S L00-FTMxxxx-0-05-xx-xx-006 Plastic housing F0 with transparent cover for FTM.. and FTM..S L00-FTMxxxx-0-05-xx-xx-007 Aluminium housing T with separate connection compartment for FTM..D and FTM..S L00-FTMxxxx-0-05-xx-xx-006 L00-FTMxxxx-0-05-xx-xx-008 Endress+Hauser 5

Process Connections Tapered thread R ½, DIN 2999 and Tapered thread ½ NPT Various flanges to DIN/EN, ASME, JIS L00-FTMxxxx-0-05-xx-xx-009 L00-FTMxxxx-0-05-xx-xx-00 Sensor versions Vibrating fork in solid stainless steel; resistant to high lateral loads L00-FTMxxxx-0-05-xx-xx-0 FTM0 compact unit L00-FTMxxxx-0-05-xx-xx-02 FTM with extension tube L00-FTMxxxx-0-05-xx-xx-0 FTM with extension tube and sliding sleeve (accessory) FTM2 with rope (can be shortened) L00-FTMxxxx-0-05-xx-xx-04 Dimensions A ø86 max. 0 98 B max. 7 ~60 5 ~60 2 max. max. 68 max.26 max. ø 4 28 50 AF ø max. 45 ø max. 4 ~20 5 22 ~20 4 ~40 A) FTM0 compact version, with thread R ½ (DIN 2999) or ½ NPT, shown with housing F6/F0 B) FTM0 compact version, with flange to EN 092-*, ASME B 6.5 or JIS 220, shown with housing F6/F0 L00-FTMxxxx-06-05-xx-en-00 6 Endress+Hauser

C max. 8.5 9 ø04 D max. 88 max. 58 28 max. 20 FTM/S: 00... 4000 FTMD: 400... 4000 70 5 max. 7 max. ø 4 5 50 AF FTM/S: 00... 4000 FTMD: 400... 4000 2 22 ø max. 45 ø max. 4 4 ~40 C) FTM with extension tube, with thread R ½ (DIN 2999) or ½ NPT, shown with housing T D) FTM with extension tube, with flange to EN 092-*, ASME B 6.5 or JIS 220, shown with housing T L00-FTMxxxx-06-05-xx-en-002 E F max. 56 max. ø 4 max. 5 5 50 AF 20 FTM2/2S: 750... 20 000 FTM2D: 000... 20 000 FTM2/2S: 8 FTM2D: 88 ø~0 max. ø 4 28 5 4 70 FTM2/2S: 750... 20 000 FTM2D: 000... 20 000 FTM2/2S: 8 FTM2D: 88 2 ø max. 45 ø max. 4 ~40 E) FTM2 with rope, with thread R ½ (DIN 2999) or ½ NPT, shown with housing F8 F) FTM2 with rope, with flange to EN 092-*, ASME B 6.5 or JIS 220, shown with housing F8 L00-FTMxxxx-06-05-xx-en-00 * compatibly with DIN 2527 B Endress+Hauser 7

Flanges see Page 8, Product Structure: Process Connection and Material. See data sheets for flange dimensions. Length tolerances for FTM Sensor length Tolerance up to m +0 mm... 5 mm up to m +0 mm... 0 mm up to 4 m +0 mm... 20 mm Length tolerances for FTM2 Sensor length Tolerance up to m +2.5 mm... 5 mm up to 20 m +2.5 mm... 20 mm Installation Soliphant FTM0 Take into account the angle of the mound or discharge hopper when determining the height of the installation point. Left: correct mounting a. Right: incorrect mounting b. e. ~20 ~250 mm ~200 mm f. c. ~200 mm g. d. max. 60 mm L00-FTMxxxx--06-xx-xx-00 The compact Soliphant version can be mounted at any position in a bulk solids vessel. Correct mounting: a. top-mounted, tines vertical but at any orientation b. laterally mounted: fork angled slightly downwards so that material can slide off more easily c. with shield: to protect against collapsing mounds (length approx. 250 mm, width approx. 200 mm) d. in discharge hopper. Max. nozzle length 60 mm (2.4 in) Incorrect mounting: e. in filling curtain f. fork orientation incorrect (broad tine surface is subjected to high load caused by discharging material; malfunction due to residual material) g. mounting nozzle too long 8 Endress+Hauser

Soliphant FTM, FTM2 Take into account the angle of the mound or discharge hopper when calculating the length of the sensor required. Clearance FTM FTM2 Sliding sleve L * FTM L00-FTMxxxx--06-xx-en-00 FTM with extension tube to be used, e.g. if mounting is only possible from above with heavy build-up on the silo wall with sliding sleeve (accessory), if the switch point is to be altered. Mount in the centre of the discharge hopper in order to keep the lateral load caused by discharging material to a minimum, or close to the vessel wall with an extra fastening near to the fork. Check that there is enough space outside the silo for mounting. *Nozzle length: max. L 70 mm FTM2 with rope (can be shortened) to be used, e.g. only top-mounting in a high silo is possible there is not enough clearance outside the silo for the long version of the Soliphant FTM. The instrument should be installed near to the vessel wall in order to keep the tension caused by discharging material to a minimum. It should not, however, be so near that it touches the wall when it swings. Endress+Hauser 9

Electrical Connection! Note! The plug-in electronic inserts can be exchanged without recalibration. A high housing cover is required for the FEM5/45. L = S = LED shows switching status Fail-safe mode is selected using a switch (with FEM7, on the Nivotester). L00-FTMxxxx-07-05-xx-xx-00 The diagrams show the direct connection of the electronic insert in the housing F6, F8 or F0. The terminals in the separate connection compartment of the housing T have the same designations as those of the built-in electronic insert. L FEM.. Min Max S A U~ L N B U... 0... 55 V L+ L A 0,5 A 9... 25 V 2 2 ( + ) FEM FEM4 FEM2 A) Electronic insert FEM, FEM4 Two-wire AC power supply Always connect in series with a load! Note the voltage drop across the electronic insert in the conducting state (max. 2 V), the residual current in the blocked state (max. 4 ma) and, when using low voltages, the voltage drop across the load. The terminal voltage at the electronic insert must never be less than 9 V! L00-FTMxxxx-04-05-xx-xx-00 B) Electronic insert FEM2 Three-wire DC power supply. Recommended for use with programmable logic controllers (PLC). Positive signal at the switching output of the electronic insert (PNP). 0 Endress+Hauser

C U~ U... 9... 25 V 9... 200 V D U~ 9... 25 V U... 9... 200 V L N L N 0,2 A 0,2 A a u r a u r a u r 2 4 5 2 4 5 7 8 9 FEM4 FEM44 FEM5 FEM45 C) Electronic insert FEM4, FEM44 Universal power supply with relay output potential-free changeover contact (SPDT) * L00-FTMxxxx-04-05-xx-xx-002 D) Electronic insert FEM5, FEM45 Universal power supply with relay output 2 potential-free changeover contacts (DPDT) * * When connecting a low-voltage circuit with double isolation according to IEC 00 the following applies: Voltage sum of power supply and relay output max. 00 V. E Input (CH) 7 d4 8 d2 FTL25P (or FTL20, FTL20Z) FTL75P (or FTL70, FTL72, FTL70Z) Input 2 (CH2) z4 4 z2 FTL25P FTL75P (or FTL72, FTL70Z) Input (CH) 7 z6 8 d6 FTL25P FTL75P safe area + explosion hazardous area 2 FEM7 I PFM signal t L00-FTMxxxx-04-05-xx-en-00 E) Electronic insert FEM7 Intrinsically-safe PFM signal transmission along two-wire cabling to the remote switching unit Nivotester FTL25 or FTL75. (Can also be connected to the earlier types FTL20Z, FTL70Z, FTL20, FTL70 or FTL72). Endress+Hauser

Technical Data General Specifications Application Operation and System Design Input Instrument family: Soliphant II Instrument types: FTM0, FTM, FTM2 FTM0D, FTMD, FTM2D FTM0S, FTMS, FTM2S Instrument function: Level limit switch Limit detection: Maximum or minimum detection in silos with powdery and fine-grained solids, max. grain size 0 mm Measuring principle: Damping of the oscillation of a fork vibrating at its resonant frequency Modularity: FTM.. and FTM..D: complete limit switch, consisting of the sensor with the integrated electronic insert FEM.. (switching unit); FTM..S: sensor with integrated electronic insert FEM7 (transmitter) for connection to remote switching unit Nivotester FTL... Signal processing: Two-wire AC version (with FEM/4): load switched directly via a thyristor in the power supply; Three-wire version (with FEM2): load switched via a transistor and separate connection; Universal version with relay output (with FEM4/44/5/45): load switched via a potential-free changeover contact; Version for remote switching unit (with FEM7): PFM signal transmission; current pulses superimposed on the current flowing in the two-wire power cabling Electrical isolation: With FEM/2/4: between sensor and power supply; With FEM4/44/5/45: between sensor and power supply and load; With FEM7: between sensor and power supply, in remote switching unit Nivotester between power supply and load Measured variable: Height (limit value, binary) Measuring range (detection range): FTM0: determined by installation point FTM: determined by sensor length (pipe) (approx. 00... 4000 mm from above, FTMD: approx. 400... 4000 mm) FTM with sliding sleeve: adjustable approx. 200... 900 mm from above FTM2: determined by sensor length (rope) (approx. 800... 20000 mm from above, FTM2D: approx. 000... 20000 mm) 2 Endress+Hauser

Output Output signal: Binary; output blocked on reaching limit Signal failure: Output blocked Load (connectable) with FEM/4 (AC, load switched via thyristor directly in the power supply): Transient (40 ms) max..5 A, max. 75 VA at 25 V or max. 6 VA at 24 V (no short circuit-protection) continuous max. 87 VA at 25 V, max. 8.4 VA at 24 V min. 2.5 VA at 25 V (0 ma), min. 0.5 VA at 24 V (20 ma) Voltage drop across FEM.. max. 2 V Residual current max. 4 ma with blocked thyristor Load (connectable) with FEM2 (DC, load switched via transistor and separate PNP connection): Transient ( s) max. A, max. 55 V (cyclic protection against overload and short circuiting); continuous max. 50 ma, max. 55 V; max. 0.5 µf at 55 V, max..0 µf at 24V; Residual voltage < V (with conducting transistor); Residual current < 00 µa (with blocked transistor) Load (connectable) with FEM4/44/5/45 (Universal current, load switched via potential-free changeover contact): FEM4/44: potential-free changeover contact (SPDT), FEM5/45: 2 potential-free changeover contacts (DPDT) I~ max. 6 A, U~ max. 25 V; P~ max.500 VA, cos ϕ =, P~ max. 750 VA, cos ϕ > 0.7; I% max. 6 A to 0 V, I% max. 0.2 A to 25 V; Load (connectable) with FEM7 (potential-free relay contact in switching unit Nivotester FTL): See Technical Data of the switching unit Nivotester FTL20, FTL70, FTL72, (FTL20Z, FTL70Z), FTL25P, FTL75P Output, General Information Fail-safe switching: Minimum or maximum fail-safe mode, switchable Switching time: FEM/2/4/4/44: Approx. 0.5 s when covered, approx..5 s when free FEM5/45: Approx. 0.5 s when covered, approx..5 s when free, switchable to approx. 2.5 s when covered, approx. 7.5 s when free Measuring Accuracy Operating Conditions Reference conditions: Temperature T = 20 C, operating pressure p e = bar, Density of material > kg/l, grain size < 2 mm Measured error: Approx. 0 mm for vertical mounting, 5 mm for lateral mounting of the sensor Settling time: The output remains open approx. 2.5 s after switching on the power supply Switching time error: +/ 25 % when covered or uncovered Effects of temperature and operating pressure: Negligible Mounting Orientation: Any position for FTM0 and FTM with short tube Vertical for FTM with long tube and FTM2 Endress+Hauser

Lateral load on fork for FTM0: 600 N (on narrow edge of tines), static Lateral load on tube for FTM: 00 Nm (max. m) Tensile strength of rope for FTM2: 2500 N Environment Operating temperature range: 40 C... +70 C Storage temperature range: 40 C... +85 C Climatic class: Climatic protection to IEC 68, Part 2-8, Fig. 2a Ingress protection (housing) IP66 to DIN 40050 Electromagnetic compatibility: FEM/2/4/4/44: Interference Emission to EN 626, Electrical Equipment Class B Interference Immunity to EN 626, Annex A (Industrial) and NAMUR Recommendation NE 2 (EMC) FEM5/45: Interference Emission to EN 626, Electrical Equipment Class A Interference Immunity to EN 626, Annex A (Industrial) and NAMUR Recommendation NE 2 (EMC) Product Temperature of product: 40 C... +50 C, see also graphs on page 6 Pressure (operating pressure) p e : bar... max. 6 bar (FTM0/), 6 bar (FTM2D), 2 bar (FTM2) Pressure limit: Burst pressure min. 00 bar (FTM0/), 40 bar (FTM2D), bar (FTM2) Density of product: min. 20 g/l Grain size of product: max. 0 mm Construction Design: FTM0: compact unit FTM: with extension tube max. 4 m FTM2: with rope max. 20 m Dimensions: See dimensioned drawings on Pages 6 and 7 Weight: See Product Structure on Pages 7, 8 and 9 Materials: Process connection (thread): stainless steel AISI 04 (.40); Flanges: AISI 6Ti (.457), tube: AISI 04 (.40), rope insulation: PUR Vibrating fork: stainless steel AISI 6Ti (.457); Housing F0: fibre-glass reinforced polyester (blue); Low transparent cover: polyamide; high transparent cover: polycarbonat Housing F6, T: aluminium GD-Al 0, DIN 725, with plastic coating; Housing F8: stainless steel AISI 6L (.4404); Seal for housing cover F6, T: EPDM (elastomer), for housing cover F8, F0: silicone; Cable gland Pg.5: polyamide with NBR seal Cable gland Pg 6: polyamide with neoprene-cr seal 4 Endress+Hauser

Process connections: Tapered thread R ½ to DIN 2999 Part ; Tapered thread ½ NPT to ASME B.20. Flanges to DIN, ASME, JIS see Product Structure. Electrical connection: Terminal screws on electronic insert for max. 2.5 mm 2 conductor in A 2.5-7 sleeves to DIN 46228; Terminal screws in separate connection compartment of housing T: for max. 2.5 mm 2 conductor in A 2.5-7 sleeves to DIN 46228 Display and User Interface Power supply Certificates and Approvals Ordering On electronic insert FEM/2/4/5/4/44/45: Rotary switch for minimum/maximum fail-safe; red LED showing switching status On electronic insert FEM7: Green LED showing status for cover Electronic insert FEM/4: Voltage at Terminal and 2: 9... 25 V, 50 / 60 Hz; Current consumption (stand-by) max. 4 ma Electronic insert FEM2: 0... 55 V, ripple max..7 V, 0... 400 Hz; current consumption max. 5 ma, reverse polarity protection Electronic insert FEM4/44/5/45: AC voltage 9... 25 V, 6... 60 Hz or DC voltage 9... 200 V; current consumption FEM4/44: max. 7 ma current consumption FEM5/45: max. 0 ma Electronic insert FEM7: powered by the switching unit Nivotester FTL ATEX, FM, CSA, TIIS: See Product Structure on Pages 7/8 Product designation: See Product Structure on Page 9 Accessories: See pages 6/7 Supplementary documentation: General information on EMC TI 24F/00/en Technical Information to separate housing HTM0E TI 274F/00/en Safety instructions for FTM#-B (ATEX II / D) XA 02F/00/a Safety instructions for FTM#S-Z (ATEX II /2 GD) XA 00F/00/a Safety instructions for FTM#S-Z + HTM0E (ATEX II /2 GD) XA 05F/00/a Safety instructions for FTM0/D-H (ATEX II 2 G, II / D) XA 066F/00/a Safety instructions for FTM2D-X (ATEX II 2 G, II / D) XA 066F/00/a Safety instructions for FTM0/D- (ATEX II 2 G, II D) XA 066F/00/a Safety instructions for FTM2D-2 (ATEX II 2 G, II D) XA 066F/00/a Safety instructions for FTM0/D- (ATEX II /2 G) XA 066F/00/a Certificates: On request Endress+Hauser 5

Permissible ambient temperature values T U at the housing as a function of the operating temperature T B in the silo: TU C 80 FTM0/, FTM0D, FTM0S/S TU C 80 FTMD 60 60 40 40 20 20 40 20 20 40 60 80 00 20 40 20 TB C 40 20 20 40 60 80 00 20 40 20 TB C 40 40 L00-FTMxxxx-05-06-xx-xx-00 L00-FTMxxxx-05-06-xx-xx-002 TU C 80 60 40 FTM2, FTM2D, FTM2S 20 40 20 20 40 60 80 00 20 40 20 TB C 40 L00-FTMxxxx-05-06-xx-xx-00 Accessories Seperate Housing HTM0E Rope Shortening Set Protective Hood for the electronic insert of Soliphant. Easier operation when the Soliphant is mounted in a confined space and wider ambient temperature range for the Soliphant housing. See Technical Information TI 274F/00/en. for Soliphant FTM2. This consists of a number of accessories which enable the rope to be shortened and make a permanent and water-tight connection with the sensor. Instructions for mounting are included. Order-No.: 95 622-000. FTM2 with standard lengths 2500 mm or 6000 mm: The rope shortening set is enclosed. Protects the field-mounted Soliphant from excessive temperatures caused by direct sunlight and prevents condensation from entering the housing due to extreme temperature variations. For housings F6, F0 Material: polyamide For low housing cover: Weight: 0. kg Order-No.: 942 262-0000 For high housing cover: Weight: 0.6 kg Order-No.: 942 262-000 0 low 04 high 42 62 L00-FTMxxxx-0-05-xx-en-00 6 Endress+Hauser

Sliding Sleeve When mounting the Soliphant FTM in the silo from above, the sliding sleeve allows the switch point to be infinitely adjusted. Maximum permissible operating pressure: 6 bar; Max. operating temperature: 50 C; Material: stainless steel.40 (AISI 04); Packing for threaded gland: Graphite; Weight:.79 kg With thread G 2 A Order-No.: 94 090-002 2 ~75 ø80 24 70 AF 28 M6x25/5AF With thread 2-½ NPT Order-No.: 94 090-02 6x68 DIN 760-A G2A DIN/ISO 228 2-½ NPT ANSI B.20. L00-FTMxxxx-06-05-xx-en-004 Product Structure Product Structure Construction For standard applications and dust explosion hazardous area FTM0 FTM FTM2 compact version with extension tube with rope Basic Weight. kg.2 kg 2.9 kg For standard applications and dust explosion hazardous area and Ex area Zone ; ignition protection EEx de FTM0D FTMD FTM2D compact version with extension tube with rope 2. kg 2.2 kg 4.0 kg For standard applications and dust explosion hazardous area and explosion hazardous area Zone ; ignition protection EEx i FTM0S FTMS FTM2S compact version with extension tube with rope. kg.2 kg 2.9 kg 0 Certificates, Applications A For non-hazardous area use For FTM0//2 B ATEX II / D D CSA DIP Cl. II, Div., Gr. E-G, Cl. III (FTM0/) E CSA DIP Cl. II, Div., Gr. G+coal dust (FTM2) F FM DIP Cl. II, Div., Gr. E-G, Cl. III 4 ATEX II D 5 ATEX II G EEx na II T6 6 ATEX II G EEx nc II T6 For FTM0D/D/2D G FM XP Cl. I, II, Div., Gr. A-G, Cl. III H ATEX II / D, ATEX II 2 G EEx de IIC T6 J TIIS (Ex d) labeling in Japan K CSA XP Cl. I, II, Div., Gr. A-G, Cl. III (FTM0D) L CSA XP Cl. I, Div., Gr. B+D, Cl. II, Div., Gr. G+coal dust, Cl. III (FTM2D) M CSA XP Cl. I, II, Div., Gr. B-G, Cl. III (FTMD) Q FM XP Cl. I, II, Div., Gr. C-G, Cl. III (FTM2D) X ATEX II / D, ATEX II 2 G EEx de IIB T6 (FTM2D) ATEX II D, ATEX II 2 G EEx de IIC T6 (FTM0D/D) 2 ATEX II D, ATEX II 2 G EEx de IIB T6 (FTM2D) ATEX II /2 G EEx de IIC T6 (FTM0D/D) Endress+Hauser 7

0 Certificates, Applications For FTM0S/S/2S N ATEX II /2 D, ATEX II /2 G EEx ia IIC T6 P FM IS Cl. I, II, Div., Gr. A-G, Cl. III S TIIS (Ex ia) labeling in Japan T CSA IS Cl. I, II, Div., Gr. A-G, Cl. III (FTM0S/S) U FM IS Cl. I, II, Div., Gr. C-G, Cl. III (FTM2S) W CSA IS Cl. I, Div., Gr. C+D, Cl. II, Div., Gr. G+coal dust, Cl. III (FTM2S) Z ATEX II /2 D, ATEX II /2 G Ex ia IIB T6 Y Special version 20 Electronics Additional Weight Two-wire, contactless, for FTM0//2, FTM0D/D/2D 9...25 V AC; 2 Three-wire, PNP, for FTM0//2, FTM0D FEM2 4 Relay SPDT, for FTM0//2, FTM0D/D/2D 5 Relay DPDT, for FTM0//2, FTM0D/D/2D 7 Two-wire PFM transmission, FEM7 for FTM0S/S/2S 8 Electronic insert not selected for FTM0//2 9 Special version 0...55 V DC 9...25 V AC; 9...200 V DC 9...25 V AC; 9...200 V DC 0, kg 0,2 kg 0 Housing and cable entry For FTM0//2 and FTM0S/S/2S B Aluminium F6 NPT ½" entry IP66 0,2 kg C Aluminium F6 G ½ A entry IP66 0,2 kg D Aluminium F6 M20 gland IP66 0,2 kg F Polyester F0 NPT ½" entry IP66 G Polyester F0 G ½ A entry IP66 H Polyester F0 M20 gland IP66 2 6L F8 G ½ A entry IP66 0,4 kg 6L F8 M20 gland IP66 0,4 kg 4 6L F8 NPT ½" entry IP66 0,4 kg For FTM0D/D/2D and FTM0S/S/2S K Aluminium T NPT ¾" entry IP66 0, kg L Aluminium T G ½ A entry IP66 0, kg M Aluminium T M20 gland IP66 0, kg Y Special version 40 Process connection, material A R ½ 04 B ½" NPT 04 H DN 50 PN 25/40 A EN 092- (DIN 2527 B) 6Ti,0 kg J DN 80 PN 0/6 A EN 092- (DIN 2527 B) 6Ti 4,5 kg K DN 00 PN 0/6 A EN 092- (DIN 2527 B) 6Ti 5,4 kg M 2" 50 lbs RF ASME B6.5 6Ti,6 kg N 4" 50 lbs RF ASME B6.5 6Ti 5,4 kg P " 50 lbs RF ASME B6.5 6Ti,7 kg 0K 50A RF JIS B220 6Ti 2,0 kg 2 0K 80A RF JIS B220 6Ti,0 kg 0K 00A RF JIS B220 6Ti 4,0 kg Y Special version 50 Additional option Basic version 9 Special version 8 Endress+Hauser

60 Probe length For FTM, FTMD, FTMS A... mm (00...4000 mm) (FTM, FTMS only) 2,0 kg/m B 500 mm,0 kg C 000 mm 2,0 kg D... mm (400...4000 mm) (FTMD only) 2,0 kg/m... in (2...55 in) (FTM, FTMS only)... in (6...55 in) (FTMD only) For FTM2, FTM2D, FTM2S J... mm (750...20000 mm) (FTM2, FTM2S only) 0, kg/m K 2500 mm 0, kg L 6000 mm 0,7 kg M... mm (000...20000 mm) (FTM2D only) 0, kg/m 2... in (0...790 in) (FTM2, FTM2S only) 4... in (40...790 in) (FTM2D only) 7 00 in 8 240 in Y Special version FTM0- FTM0D- FTM0Scomplete product designation FTM/2- FTMD/2D- FTMS/2Scomplete product designation! Note! Basic Weight:: without extension tube without rope with threaded boss with electronic insert with plastic housing F0 for FTM.. and FTM..S with aluminium housing T for FTM..D Endress+Hauser 9

International Head Quarter Endress+Hauser GmbH+Co. KG Instruments International Colmarer Str. 6 79576 Weil am Rhein Deutschland Tel. +49 76 2 9 75 02 Fax +49 76 2 9 75 4 5 www.endress.com info@ii.endress.com TI249F/00/en/02.04 SL/FM+SGML6.0 ProMoDo