Backflow Prevention Products

Similar documents
w w w. w a t t s. c o m

Backflow Prevention Products and Parts

MADE IN THE USA BACKFLOW PREVENTERS

Backflow Preventers TABLE OF CONTENTS

4P-300 4V-500 CONTINUOUS PRESSURE THERMOPLASTIC DUAL. PRINCIPLE (U & Z Flow) DUAL CHECK VALVE. PRINCIPLE (Stn.Steel) REDUCED PRESSURE

BACKFLOW PREVENTION CATALOG

DCAP Series 40-4 X X - X X X. Dual Check w/ Atmospheric Port Backflow Preventers

AMES 2013 Price List. Backflow Prevention Products. Effective April 1, 2013

AMES 2016 Price List. Backflow Prevention Products and Repair Kits and Parts. Effective February 29, 2016

Price List. Backfl ow Prevention Products, Repair Kits, and Parts. Effective July 2, AmesFireWater.com 2018 AMES FIRE & WATERWORKS PRICE LIST

LEAD FREE * PVS-7000 Engineered Flood Protection Valve Station with SentryPlus Alert

INSTALLATION, OPERATION, AND MAINTENANCE MANUAL

Awide choice of devices

THE DEFENDER 4D-200 SERIES

THE WARRANTY SET FORTH HEREIN IS GIVEN EXPRESSLY AND IS THE ONLY WARRANTY GIVEN BY THE COMPANY WITH RESPECT TO THE PRODUCT.

Irrigation Series. Backflow Preventers, Water Pressure Regulators, and Water Control Products for Irrigation Applications

BACKFLOW PREVENTION CATALOG

SECTION GENERAL-DUTY VALVES FOR PLUMBING PIPING

SECTION GENERAL-DUTY VALVES FOR PLUMBING PIPING

AMES 2000 SS/2000 SE. BASIC REPAIR KIT Repair kit contains all check modules and O-rings

Series 007. Double Check Valve Assembly. Installation Service Repair Kits Maintenance. Sizes: 1 2" 3" Watts 3 4" 007M3QT RP/IS-007

LEAD FREE * LFF113RFP Flood Protection Shut Down Valve

A. This Section includes the following domestic water piping specialties:

LEAD FREE * LFF113RFP Wireless Smart Flood Protection Shut Down Valve with SentryPlus Alert Technology

Valve Selection. 1. Function and service considerations

FLOOD PROTECTION SHUT DOWN VALVE (3 and smaller)

SECTION GENERAL-DUTY VALVES FOR PLUMBING PIPING

Price List. Backflow Prevention Products and Repair Kits. Effective Date October 30, FEBCOonline.com 2017 FEBCO PRICE LIST

Price List. Backflow Prevention Products and Repair Kits. Effective Date July 2, FEBCOonline.com 2018 FEBCO PRICE LIST

Irrigation Solutions. Backflow Preventers, Water Pressure Regulators, and Water Control Products for Irrigation Applications.

MAG- Backflow Preventers. MAG-BEECO Backflow Preventers deliver the highest level of performance, reliability, ease of use and save time and money.

PASSAIC COUNTY TECHNICAL INSTITUTE CCA 1422 NEW S.T.E.M. BUILDING 2017

See Water Pressure Reducing Valves Catalog (PHBRWPRV) for more detailed information about the products in this section.

See Water Pressure Reducing Valves Catalog (PHBRWPRV) for more detailed information about the products in this section.

LEAD FREE * LFF113FP. Wireless Smart Flood Protection Shut Down Valve with SentryPlus Alert Technology. Materials NOTICE NOTICE ES--LFF113FP

Section - L. Antipollution devices

Series 957, 957N, 957Z, 957RPDA, 957NRPDA, 957ZRPDA

Backflow Prevention. Quick Reference Guide

Series 867 Reduced Pressure Zone Assemblies

Backflow Preventers & Accessories

Colt Series C400, C500

Rigid/Swivel Optional Spouts

08.20 VIC -300 MasterSeal Butterfly Valves

2 ½ 12. Model RP 4A Model RPDA 4A Model RPDA2 4A. Installation, Operation, and Maintenance Manual

SECTION GENERAL-DUTY VALVES FOR PLUMBING PIPING

Maintenance Manual Double Check and Double Check Detector Assemblies Series 850, 856, 870V & 876V 2 1 /2" - 10" (65 250mm)

Stainless Steel The Next Generation of Backflow

THIS WARRANTY IS IN LIEU

HERSEY 6CM SIZE 2 1/2", 3", 4", 6", 8", 10"

LEAD FREE * LFF115 (Globe) LFF1115 (Angle)

Maintenance Manual Reduced Pressure Assembly Models 860 & 880V 2 1 /2" 10"

MODEL 106/206-PG POWER OPERATED GLOBE VALVE Sizes 1/2" to 8" (106-PG) 3" to 10" (206-PG) Installation, Operating and Maintenance Instructions

SECTION VALVES

1. All piping shall have flow arrows indicating direction of flow.

MAINTENANCE MANUAL. Covering Models: Series (1/4-10 ) S Series (1/4-1 ) Series (3-10 )

Cash-Flo. Operation & Maintenance Manual. BackFLOW PREVENTERS. A Division of the Reliance Worldwide Corporation

THE WARRANTY SET FORTH HEREIN IS GIVEN EXPRESSLY AND IS THE ONLY WARRANTY GIVEN BY THE COMPANY WITH RESPECT TO THE PRODUCT.

Installation, Maintenance, & Repair Series 995 Reduced Pressure Zone Backflow Preventers

LEAD FREE * LFM115 (Globe) LFM1115 (Angle)

Installation, Maintenance, & Repair Series 919 and LF919

A. This Section includes the following domestic water piping specialties:

British Standard institute-bs Valve Standards

Valves & Flow Control Components Valves & Flow Control Components

FM 3. FM 3 with Bypass. Materials and Specifications. Fire Service Meter with Bypass Sizes 3, 4, 6, 8, 10. Features

Henderson Engineers, Inc. SECTION GENERAL DUTY VALVES FOR PLUMBING PIPING PART 1 - GENERAL REQUIREMENTS

SECTION PLUMBING PIPING VALVES AND ACCESSORIES PART 1 - GENERAL

2 ½ 12. Installation, Operation, and Maintenance Manual. Reduced Pressure Principle Backflow Preventer. Reduced Pressure Detector Assembly

PACIFIC. for Agricultural Irrigation Applications. exceptional quality unparalleled performance

DIMENSIONS (approximate)

Lead-free valves for potable water systems. Rev 02/17

Flood Control Integrated System (FCIS)

Series 990/990RPDA. Reduced Pressure Zone Backflow Preventer. Sizes: 4", 6", 8" (100mm, 150mm, 200mm)

AMES 2015 Price List. Backflow Prevention Repair Kits and Parts. Effective March 30, Includes Our. Product Offering.

CROSS-CONNECTION CONTROL MANUAL

Check Valve MODEL. Schematic Diagram. Product Dimensions Data:

VALVCHEQ BACKFLOW PREVENTERS FIGURE DC03

Series 77S-M1 ( 1 4" 3") Cast Iron Wye-pattern Strainers

Double Check Backflow Preventer 314" to 2"

Zurn Wilkins Fire Protection Series. Backflow Preventers, Pressure Regulating Valves, and Water Control Products for Fire Sprinkler Applications

SECTION GENERAL-DUTY VALVES FOR PLUMBING PIPING

SECTION GENERAL-DUTY VALVES FOR PLUMBING PIPING

Series 995/995RPDA. Sizes: 3" - 6" Reduced Pressure Zone Backflow Preventer/ Reduced Pressure Detector Assemblies RP/IS-995/995RPDA

Compact wafer-style design and round unobstructed port tackle many tough applications.

Backflow Irrigation Control Station BIC-1000

Michigan State University Construction Standards. GENERAL-DUTY VALVES FOR PLUMBING PIPING Page

1 Visit for more details. Contact the Factory at

OPTIMAL VALVE SOLUTIONS FOR OIL AND GAS PLANTS

Self-Operating Temperature Regulators

SECTION VALVES PART 1 -GENERAL

BALL VALVES. Industry-Leading 300psi Low Lead Ball Valves

4000SS. For other repair kits and service parts, send for Ames Repair Parts Price List, PL-A-RP-BPD.

A. This Section includes general duty valves common to several HVAC piping systems.

35 Dealing with Type II and N Pattern Assemblies Pete Chapman

Lead-free valves for potable water systems.

Installation Service Repair Kits Maintenance RP/IS-774/774DCDA/774X/774XDCDA

Brown University Revised August 3, 2012 Facilities Design & Construction Standards SECTION HVAC&R VALVES

Approved Branded Traceable Fire Protection & Waterworks Valves

Series 009. Reduced Pressure Zone Assemblies. Installation Service Repair Kits Maintenance. Sizes: 8 80mm. 80mm 009LF RP/IS-009-AUS

Butterfly Valves. watts.com

WATTS/Taras. Water Treatment Valves and Accessories. Commercial. Residential

Transcription:

Backflow Prevention Products watts.com

Table of Contents General Information.................................................................................2 Backflow pplications..............................................................................2 Section Double Check Valve ssemblies 757, 757N.................................................................................4 757Na....................................................................................6 774......................................................................................8 709.....................................................................................0 007.....................................................................................2 79.....................................................................................4 Section 2 Double Check Detector ssemblies 757DCD, 757NDCD......................................................................6 757NaDCD..............................................................................8 774DCD................................................................................20 709DCD................................................................................22 007DCD................................................................................24 Section Reduced Pressure Zone ssemblies 957, 957N, 957Z...........................................................................26 994.....................................................................................28 994BLT, 994MB..........................................................................29 909.....................................................................................0 909.....................................................................................2 009.....................................................................................4 99.....................................................................................6 Section 4 Reduced Pressure Detector ssemblies 957RPD, 957NRPD......................................................................8 994RPD................................................................................40 909RPD................................................................................42 Section 5 Dual Check Valves 9.......................................................................................44 9D......................................................................................45 SD-2, SD-...............................................................................46 7.......................................................................................47 Cu7.....................................................................................47 L7U2-2..................................................................................48 7B......................................................................................48 07S.....................................................................................48 Section 6 Vacuum Breakers 8.......................................................................................49 800M4QT, 800M4FR.......................................................................50 008PCQT................................................................................50 88, 288, 289, N88.....................................................................5 Section 7 Miscellaneous Backflow Products WB.....................................................................................52 TWS....................................................................................54 Governor 80..............................................................................54 SS07F...................................................................................54 Test Kits.................................................................................55 Test Cocks...............................................................................56 Caps & Tethers............................................................................56 ir Gaps, Elbows..........................................................................57 Spools, Flanges...........................................................................58 PVS-000 Pre-engineered Valve Stations.......................................................59 BIC-000 Backflow Irrigation Control Stations...................................................60 FR 500 Thermostatic Freeze Relief Kits.........................................................6 Section 8 Guide to Options......................................................................62 Section 9 Flow Charts...........................................................................64 Note: Watts product specifications in U.S. customary units and metric are approximate and are provided for reference only. For precise measurements, please contact Watts Technical Service. Watts reserves the right to change or modify product design, construction, specifications, or materials without prior notice and without incurring any obligation to make such changes and modifications on Watts products previously or subsequently sold. Noryl is a registered trademark of General Electric Company.

General Information Backflow is defined as the reverse flow of a liquid into the potable water supply. The installation of a backflow preventer protects the water supply from contamination from this very serious condition. This product guide includes information on Watts complete line of backflow prevention devices. Should you require additional information, contact your local Watts Representative listed on the back of this guide. Code Requirements ll major plumbing code bodies address protection against backflow. ll potential or existing cross connections must be protected from backflow by the installation of a proper backflow prevention device. Consult your national and local plumbing code authorities for more specific information on your code requirements. 757 OSY Backflow Definitions Backpressure: pressure, higher than the supply pressure, caused by a pump, elevated tank, boiler, or any other means that may cause backflow Backsiphonage: backflow caused by negative or reduce pressure in the supply piping Cross-Connection: a connection or a potential connection between any part of the potable water system and other environment containing substances in a manner that under any circumstances would allow such a substance to enter the potable water system. Other substances may be gases, liquids, or solids, such as chemicals, waste products, steam, water from other sources (potable or non-potable) or any other matter that may change the color or add odor to the water. Bypass arrangements, jumper connections, removable sections, swivel or changeover assemblies, or any other temporary or permanent connecting arrangement through which backflow may occur are considered to be cross connections. ealth azard: a cross-connection or potential cross-connection involving any substance that could, if introduced into the potable water supply, cause death, illness, or spread disease, or have a high probability of causing such effects Non-ealth azard: a cross-connection or potential cross-connection involving any substance that generally would not be a health hazard but constitutes a nuisance or would be aesthetically objectionable, if introduced into the potable water supply Backflow pplications TYPE & PURPOSE DESCRIPTION INSTLLED T EXMPLES OF INSTLLTION REDUCED PRESSURE ZONE SSEMBLIES For health hazard crossconnections and continuous pressure applications. Two independent check valves with intermediate relief valve. Supplied with shutoff valves and ball type test cocks. ll cross-connections subject to backpressure or back siphonage where there is a potential health hazard. Main supply lines Commercial boilers ospital equipment Laboratory equipment Waste digesters Car washes REDUCED PRESSURE DETECTOR SSEMBLIES ealth hazard cross-connections and continuous pressure applications. RPZ backflow preventers with a water meter and RPZ in the bypass line. Fire protection system supply main. Detects leaks and unauthorized use of water. Fire Sprinkler Lines where additives or foaming agents are utilized. DOUBLE CECK VLVE SSEMBLIES For non-health hazard cross-connections and continuous pressure applications. Two independent check valves. Checks are replaceable for repair & testing. ll cross-connections subject to backpressure or back siphonage where there is a non-health hazard. Main supply lines Food cookers Tanks and Vats Lawn sprinklers Fire Sprinkler Lines Commercial Pools DOUBLE CECK DETECTOR SSEMBLIES For non-health hazard cross-connections and continuous pressure applications. Double check valve backflow preventers with water meter and double check in the bypass line. Fire protection system supply main. Detects leaks and unauthorized use of water. Fire Sprinkler Lines 2

Backflow pplications (cont.) TYPE & PURPOSE DESCRIPTION INSTLLED T EXMPLES OF INSTLLTION DUL CECK VLVE BCK PREVENTERS For non-health hazard cross-connections and continuous pressure applications. Two independent check valves. Checks are replaceable for repair and testing. Cross-connection where there is a non-health hazard. Residential Supply Lines (at the meter) Residential fire sprinkler systems Post-Mix beverage machines, tea and coffee machines SPECILTY BCK PREVENTERS with INTERMEDITE TMOSPERIC VENT For non-health hazard cross-connections in small pipe sizes. Continuous pressure applications. Two independent check valves with intermediate vacuum breaker and relief vent. Cross-connection subject to backpressure or backsiphonage where there is non-health hazard. Continuous pressure. Pressure outlet to prevent backflow of carbon dioxide gas and carbonated water into the water supply system to beverage machines Boilers (small) Dairy equipment Post-Mix carbonated beverage machine, tea and coffee machines, ice machines LBORTORY FUCET DUL CECK VLVE with INTERMEDITE VCUUM BREKER In small pipe sizes for health hazard cross-connections not subject to continuous pressure Two independent check valves with intermediate vacuum breaker and relief vent. Cross-connection subject to backpressure or back siphonage where there is a health hazard. Laboratory Faucets and Pipe Lines Barber shop and Beauty Parlor sinks TMOSPERIC VCUUM BREKERS For health hazard cross-connections not subject to continuous pressure 6" above flood rim. Single float and disc with atmospheric port Cross-connection not subject to backpressure or continuous pressure. Install at least 6" above fixture rim. Protection against back siphonage only. Process Tanks Dishwashers Soap Dispensers Washing Machines Lawn Sprinklers PRESSURE VCUUM BREKERS For health hazard cross-connections. Continuous pressure applications 2" above flood rim. Spring-loaded float and disc with independent check. Supplied with shutoff valves and ball type test cocks Valve is designed for installation in a continuous pressure system 2" above the overflow level of the system being supplied. Protection against backsiphonage only. Laboratory equipment Cooling towers Commercial Laundry Machines Swimming Pools Chemical Planting tanks Lawn Sprinklers NTI-SIPON, SPILL-RESISTNT VCUUM BREKERS For health hazard cross-connections. Continuous pressure applications. Factory installed " above flood rim Field installed 6" above flood rim. Spill-resistant vacuum breaker with modular check and float assembly of thermoplastic. ousing bronze body. Indoor point of use cross-connections Chemical Dispenser Commercial Dishwasher Sterilizers OSE CONNECTION VCUUM BREKERS For residential and industrial hose supply outlets not subject to continuous pressure. Single check with atmospheric vacuum breaker vent. Install directly on hose bibbs, service sinks and wall hydrants. Not for continuous pressure. ose bibbs Service sinks ydrants ENCLOSURES To protect backflow preventers installed outdoors from vandalism and cold temperatures. luminum or fiberglass structures used to protect meters, valves, and backflow preventers from vandalism and freeze damage. Backflow preventer location. Irrigation systems and domestic service line connections.

Series 757, 757N Double Check Valve ssemblies Sizes: 2 2" 0" (65 250mm) Double Check Valve ssemblies 757 OSY 757N BFG Series 757, 757N Double Check Valve ssemblies are used to prevent backflow of pollutants that are objectionable but not toxic, from entering the potable water supply system. This Series can be applied, where approved by the local authority having jurisdiction, on non-health hazard installations. The 757, 757N may be installed under continuous pressure service and may be subjected to backpressure. The 757, 757N consist of two independently operating check valves, two shutoff valves, and four test cocks. 757 OSY (Vertical) Features Extremely compact design 70% lighter than traditional designs Groove fittings allow integral pipeline adjustment Patented tri-link checks provide lowest pressure loss Unmatched ease of serviceability vailable with grooved butterfly valve shutoffs May be used for horizontal, vertical or N pattern installations Replaceable check disc rubber Materials ousing & Sleeve: 04 (Schedule 40) Stainless Steel Elastomers: EPDM, Silicone and Buna-N Tri-link Checks: Noryl, Stainless Steel Check Discs: Reversible Silicone or EPDM Test Cocks: Bronze Body Nickel Plated Pins & Fasteners: 00 Series Stainless Steel Springs: Stainless Steel Pressure Temperature Temperature Range: F 0 F (0.5 C 4 C) Maximum Working Pressure: 75psi (2. bar) Models Suffix NRS - non-rising stem resilient seated gate valves OSY - UL/FM outside stem and yoke resilient seated gate valves OSY FxG - flanged inlet gate connection and grooved outlet gate connection OSY GxF - grooved inlet gate connection and flanged outlet gate connection OSY GxG - grooved inlet gate connection and grooved outlet gate connection BFG - 2 2" 8" UL/FM grooved gear operated butterfly valves with tamper switch QT - 2 2" " quarter-turn, ball valves vailable with grooved NRS gate valves - consult factory Post indicator plate and operating nut available - consult factory Consult factory for dimensions pprovals # Testcock Tri-link Check Modules Quick ccess Sleeve Corrosion Resistant 00 Series Stainless Steel Body and Sleeve Replaceable Seat Discs 05 (BFG & OSY only) B64.5 4 For additional information, request literature ES-757/757N. See Flow Charts on p. 70

Dimensions Weights C (open) J I 757, 757N D SIZE (DN) DIMENSIONS (PPROX.) WEIGT C (OSY) C (NRS) D G I J P 757NRS 757OSY 757N NRS 757N OSY in. mm in. mm in. mm in. mm in. mm in. mm in. mm in. mm in. mm in. mm lbs. kgs. lbs. kgs. lbs. kgs. lbs. kgs. 2 2 65 787 6 8 46 9 8 28 2 89 29 6 78 22 559 5 2 9 8 6 22 9 6 24 5 52 25 57 2 56 60 80 6 805 8 7 8 479 0 4 260 6 94 0 4 768 22 4 578 7 8 45 9 6 2 0 2 267 59 45 66 44 65 58 72 4 00 6 856 22 4 578 2 6 0 4 02 88 24 60 8 2 470 9 5 6 252 6 284 6 7 6 7 84 8 84 8 6 50 4 2 05 0 8 765 6 406 5 2 40 44 4 7 4 857 2 6 589 6 2 5 8 27 24 295 4 4 42 6 52 8 200 50 270 7 4 959 9 5 6 506 6 6 70 54 8 75 40 5 8 02 27 7 6 697 5 6 99 7 6 47 48 99 480 28 5 2 555 252 0 250 57 2 460 45 4 62 2 6 605 8 6 208 66 676 50 270 2 2 826 7 5 6 440 20 508 72 27 78 54 89 404 95 4 G P Double Check Valve ssemblies C D J I G P 757 BFG, 757N BFG SIZE (DN) DIMENSIONS (PPROX.) WEIGT C D G I J P 757BFG 757N BFG in. mm in. mm in. mm in. mm in. mm in. mm in. mm in. mm in. mm lbs. kgs. lbs. kgs. 2 2 65 28 7 8 20 2 89 29 7 8 759 22 559 4 5 6 79 8 6 22 9 229 56 25 64 29 80 28 2 724 8 5 6 2 6 94 0 6 779 22 4 578 5 7 6 92 9 6 2 9 2 24 54 24 67 0 4 00 29 6 74 8 5 6 227 6 94 5 6 8 24 60 6 4 42 9 5 6 252 0 254 6 28 84 8 6 50 6 2 927 0 254 5 27 4 6 097 4 857 9 6 500 6 2 0 2 267 7 5 57 7 8 200 4 092 2 4 6 2 65 5 6 297 40 5 8 02 2 5 6 592 5 6 99 4 6 6 26 8 7 5 C D J I 757 QT P G P SIZE (DN) DIMENSIONS (PPROX.) WEIGT C D G I J P P in. mm in. mm in. mm in. mm in. mm in. mm in. mm in. mm in. mm in. mm lbs. kgs. 2 2 65 28 5 6 75 4 7 8 24 6 97 0 4 768 24 2 622 6 9 6 42 8 289 0 7 6 265 8 5 6 2 5 6 80 0 6 767 4 6 22 7 8 98 0 4 768 24 2 622 7 6 47 4 258 0 7 6 265 8 9 6 27 45 2 IMPORTNT: Inquire with governing authorities for local installation requirements 5

Series 757Na Double Check Valve ssemblies Sizes: 2 2" 6" (65 50mm) Double Check Valve ssemblies 757Na BFG Series 757Na Double Check Valve ssemblies are used to prevent backflow of pollutants that are objectionable but not toxic, from entering the potable water supply system. This Series can be applied, where approved by the local authority having jurisdiction, on non-health hazard installations. The 757Na may be installed under continuous pressure service and may be subjected to backpressure. The 757Na consist of two independently operating valves, two shutoff valves, and four test cocks. Features Extremely compact design 70% lighter than traditional designs Groove fittings allow integral pipeline adjustment Patented bi-link checks provide lowest pressure loss Unmatched ease of serviceability vailable with grooved butterfly valve shutoffs Used for N pattern installations Replaceable check disc rubber Materials ousing & Sleeve: 04 (Schedule 40) stainless steel Elastomers: EPDM and Buna-N Bi-link Checks: Noryl, stainless steel Check Discs: Reversible EPDM Test Cocks: Bronze body nickel plated Pins & Fasteners: 00 Series stainless steel Springs: Stainless steel Pressure Temperature Temperature Range: F 0 F (0.5 C 4 C) Maximum Working Pressure: 75psi (2. bar) Models Suffix NRS non-rising stem resilient seated gate valves OSY UL/FM outside stem and yoke resilient seated gate valves OSY FxG - flanged inlet gate connection and grooved outlet gate connection OSY GxF - grooved inlet gate connection and flanged outlet gate connection OSY GxG - grooved inlet gate connection and grooved outlet gate connection BFG - 2 2" 6" (65 50mm) UL/FM grooved gear operated butterfly valves with tamper switch vailable with grooved NRS gate valves - consult factory Post indicator plate and operating nut available - consult factory Consult factory for dimensions pprovals # Testcock Bi-link Check Modules Quick ccess Sleeve Corrosion Resistant 00 Series Stainless Steel Body and Sleeve Replaceable Seat Discs 05 (BFG & OSY only) B64.5 6 For additional information, request literature ES-757a/757Na. See Flow Charts on p. 70 7

Dimensions Weights J I 757Na G SIZE (DN) DIMENSIONS (PPROX.) WEIGT G I J P 757Na NRS 757Na OSY in. mm in. mm in. mm in. mm in. mm in. mm lbs. kgs. lbs. kgs. 2 2 65 29 6 78 22 559 5 2 9 8 6 22 9 6 24 2 56 60 80 0 4 768 22 4 578 7 8 45 9 6 2 0 2 267 44 65 58 72 4 00 88 24 60 8 2 470 9 5 6 252 6 284 84 8 84 8 6 50 44 4 7 4 857 2 6 589 6 2 5 8 4 42 6 52 Note: For 2 /2" 6" horizontal/vertical installation, see page 4-5. P Double Check Valve ssemblies J I 757Na BFG G P SIZE (DN) DIMENSIONS (PPROX.) WEIGT G I J P 757Na BFG in. mm in. mm in. mm in. mm in. mm in. mm lbs. kgs. 2 2 65 29 7 8 759 22 559 4 5 6 79 8 6 22 9 229 64 29 80 0 6 779 22 4 578 5 7 6 92 9 6 2 9 2 27 0 4 00 5 6 8 24 60 6 4 42 9 5 6 252 0 254 84 8 6 50 4 6 097 4 857 9 6 500 6 2 0 2 267 57 7 Note: For 2 /2" 6" horizontal/vertical installation, see page 4-5. IMPORTNT: Inquire with governing authorities for local installation requirements 7

Series 774 Double Check Valve ssemblies 774: Sizes: 2 2" 2" (00 00mm) Double Check Valve ssemblies 774 OSY Series 774 and Double Check Valve ssemblies are designed to prevent the reverse flow of polluted water from entering into the potable water system. These models can be applied, where approved by the local authority having jurisdiction, on non-health hazard installations. Series 774 feature short end-toend dimensions, light weight stainless steel body, and the lowest head loss available. Features Patented torsion spring check valve provides low head loss Short lay length is ideally suited for retrofit installations Stainless Steel body is half the weight of competitive designs reducing installation and shipping cost Stainless steel construction provides long term corrosion protection and maximum strength Single top access cover with two-bolt grooved style coupling for ease of maintenance Thermoplastic and stainless steel check valves for trouble-free operation No special tools required for servicing Compact construction allows for smaller vaults and enclosures May be installed in horizontal or vertical flow up position Materials ll internal metal parts: 00 Series stainless steel Main valve body: 00 Series stainless steel Check assembly: Noryl Pressure Temperature Temperature Range: F 0 F (0.5 C 4 C) continuous Maximum Working Pressure: 75psi (2. bar) Replaceable Seat Stainless Steel Cover Testcocks Captured Torsion Spring Grooved Coupling Resilient Disc Laser Cut/Polished Cam rm 8 For additional information, request literature ES-774 or ES-774X/774XDCD. See Flow Charts on p. 72 7

Dimensions Weights C (open) M G N 774 L SIZE (DN) DIMENSIONS (PPROX.) STRINER DIMENSIONS WEIGT C (open) C (NRS) D G L P M N w/gates w/o Gates in. mm in. mm in. mm in. mm in. mm in. mm in. mm in. mm. in. mm in. mm lb. kg. lb. kg. 2 2 65 8 965 6 8 46 9 8 28 2 89 0 254 22 559 2 2 8 0 254 6 2 65 55 70 68 80 8 965 8 7 8 479 0 4 260 4 95 0 254 22 559 0 0 2 257 7 78 20 04 70 2 4 00 40 06 22 4 578 2 6 0 4 2 4 0 254 22 559 4 2 68 2 8 08 8 4 20 225 02 58 26 6 50 48 2 22 0 8 765 6 406 5 2 40 5 8 27 2 699 5 2 94 8 2 470 2 4 75 70 05 48 8 200 52 2 4 7 4 959 9 5 6 506 6 4 7 5 8 29 2 749 8 4 464 2 5 8 549 5 2 94 56 254 69 77 0 250 55 2 40 45 4 62 2 6 605 8 200 5 8 29 2 749 9 2 495 26 660 8 2 470 76 46 79 8 2 00 57 2 46 5 8 49 26 4 679 9 2 24 5 8 29 2 749 2 5 29 7 8 759 2 4 552 0 469 209 95 D P Double Check Valve ssemblies Models Suffix NRS - non-rising stem resilient seated gate valves OSY - UL/FM outside stem & yoke resilient seated gate valves LF - without shutoff valves S - cast iron strainer OSY FxG - flanged inlet gate connection and grooved outlet gate connection OSY GxF - grooved inlet gate connection and flanged outlet gate connection OSY GxG - grooved inlet gate connection and grooved outlet gate connection vailable with grooved NRS gate valves - consult factory Post indicator plate and operating nut available - consult factory Consult factory for dimensions pprovals 05 (OSY only) (OSY only) For additional approvals consult factory. Flange dimension in accordance with WW Class D IMPORTNT: Inquire with governing authorities for local installation requirements 9

Series 709 Double Check Valve ssemblies Sizes: 2 2" 0" (65 250mm) Double Check Valve ssemblies 709 OSY Series 709 Double Check Valve ssemblies are designed to prevent the reverse flow of polluted water from entering into the potable water system. This Series can be applied, where approved by the local authority having jurisdiction, on non-health hazard installations. Series 709 features a modular check design concept to facilitate easy maintenance. Features Replaceable bronze seats Maximum flow at low pressure drop Design simplicity for easy maintenance No Special Tools Required for Servicing Captured spring assemblies for safety pproved for vertical flow up installation Materials Check Valve Bodies: Epoxy coated (FD approved) cast iron Seats: Bronze Pressure Temperature Temperature Range: F 0 F (0.5 C 4 C) continuous, 40 F (60 C) intermittent Maximum Working Pressure: 75psi (2. bar) Check ssembly Module BV Style Test Cock Bolted Cover Resilient Disc Replaceable Seat 0 For additional information, request literature ES-709L. See Flow Charts on p. 68

Dimensions Weights M C (Open) N 709 L SIZE (DN) DIMENSIONS (PPROX.) STRINER DIMENSIONS WEIGT C(OSY) C(NRS) D L R T M N N (OSY) (NRS) in. mm in. mm in. mm in. mm in. mm in. mm in. mm in. mm in. mm in. mm in. mm lbs. kgs. lbs. kgs. 2 2 65 9 99 6 8 46 9 8 28 2 89 24 60 4 02 76 0 254 6 2 65 0 254 95 88 67 76 80 40 06 8 7 8 479 0 4 260 4 95 24 60 5 27 76 0 4 260 7 78 0 254 20 9 67 76 4 00 52 2 22 4 578 2 6 0 4 2 4 4 864 6 52 6 52 2 8 08 8 4 20 2 05 428 94 68 67 6 50 6 4 607 0 8 765 6 406 5 2 40 42 2 089 279 7 2 9 8 2 470 2 4 20 508 860 90 627 284 8 200 75 905 7 4 959 9 5 6 506 6 5 8 68 52 2 4 286 9 229 2 5 8 549 5 2 94 22 4 578 448 656 20 545 0 250 90 2286 45 4 62 2 6 605 8 20 64 626 2 2 8 0 4 260 26 660 8 2 470 28 7 27 076 200 908 Dimensions needed for screen removal. D R T Double Check Valve ssemblies Models Suffix NRS - non-rising stem resilient seated gate valves OSY - UL/FM outside stem and yoke resilient seated gate valves LF - without shutoff valves S-FD - FD epoxy coated strainer BB - bronze body 2 2" " (65 80mm) QT - quarter-turn ball valves QT-FD - FD epoxy coated quarter-turn ball valves pprovals 05 (OSY only) WW pproved by the Foundation for Cross- Connection Control and ydraulic Research at the University of Southern California. Sizes 4" 0" (00 250mm) approved horizontal and vertical flow up Size 2 2" and " (65 and 80mm) approved horizontal only. Factory Mutual approved 4" 0" (80 250mm) vertical flow up IMPORTNT: Inquire with governing authorities for local installation requirements

Series 007 Double Check Valve ssemblies Sizes: 2" " (5 80 mm) Double Check Valve ssemblies 4" 007MQT 2" 007MQT C Series 007 Double Check Valve ssemblies shall be installed at referenced cross-connections to prevent the backflow of polluted water into the potable water supply. Only those cross-connections identified by local inspection authorities as non-health hazard shall be allowed the use of an approved double check valve assembly. Features Ease of maintenance - only one cover Top entry Replaceable seats and seat discs Modular construction Compact design Top mounted ball valve test cocks Low pressure drop No special tools required for servicing 2" " (5 25 mm) have tee handles 2" 2" (5 50mm) cast bronze body construction 2 2" " (65 80mm) fused epoxy coated cast iron body Materials Body: 2" 2" (5 50mm) Cast bronze 2 2" " (65 80mm) Fused epoxy coated cast iron body Pressure Temperature Temperature Range: 2" 2" (5 50mm) F 80 F (0.5 C 82 C) 2 2" " (65 80mm) F 0 F (0.5 C 4 C) continuous, 40 (60 C) intermittent Maximum Working Pressure: 75psi (2. bar) Models 2" 2" (5 50mm) Suffix QT - quarter turn ball valves LF - without shutoff valves L - locking handle ball valves (open position) S - stainless steel ball valve handles C - 2 2" inlet/outlet fire hydrant fitting (2" valve) S - bronze strainer PC - polymer coating Prefix U - union connections 2 2" and " (65 and 80mm) Suffix NRS - non-rising stem resilient seated gate valves OSY - UL/FM outside stem & yoke resilient seated gate valves LF - without shutoff valves QT-FD - FD epoxy coated quarter-turn ball valves pprovals 05 WW, IPMO, UPC pproved by the Foundation for Cross- Connection Control and ydraulic Research at the University of Southern California. orizontal and vertical flow up approval on all sizes. UL Classified (LF models only) 4" 2" (9 50mm) UL Classified with OSY gate valves (2 2" & ") First Check Module ssembly Test Cocks Second Check Module ssembly 2 For additional information, request literature ES-709L. See Flow Charts on p. 64

Dimensions Weights M C Suffix C - Fire ydrant Fittings dimension = 2 2" (594mm) 007QT N N F SIZE (DN) DIMENSIONS (PPROX.) STRINER DIMENSIONS WEIGT B C F G I M N N in. mm in. mm in. mm in. mm in. mm in. mm in. mm in. mm in. mm in. mm in. mm lbs. kgs. 2 5 0 254 4 5 8 7 2 7 6 62 5 27 8 85 2 5 6 59 2 6 52 2 4 70 2 4 57 0 254 4 2 2 4 20 8 282 4 02 8 79 6 6 57 7 6 87 2 8 54 5 6 6 8 2 4 70 0 254 5 2. 25 4 7 5 8 0 4 02 7 2 9 8 85 6 4 6 4 4 95 76 2 05 2 5.4 4 2 6 8 46 5 27 5 6 84 9 2 24 5 27 76 2 50 4 7 6 2 89 20 508 5 6.8 2 40 6 4 425 4 7 8 24 2 89 9 4 248 5 6 48 8 79 2 6 68 4 7 8 24 4 0 22 4 578 5 7 8 7.2 2 50 9 2 495 6 4 59 4 02 8 40 6 8 56 7 6 87 2 6 68 5 5 6 5 5 27 28 7 25 4.7 Dimensions required for screen removal. B G I Double Check Valve ssemblies M C (open) N E D R MODEL NO. SIZE (DN) DIMENSIONS (PPROX.) STRINER DIMENSIONS WEIGT C D E R M N in. mm in. mm in. mm in. mm in. mm in. mm in. mm in. mm lb. kgs. 007-NRS 2 2 65 8 84 9 8 5 6 09 8 8 460 8 4 222 0 254 6 2 65 55 70 007-OSY 2 2 65 8 84 6 8 46 4 5 6 09 8 8 460 8 4 222 0 254 6 2 65 58 72 007QT-FD 2 2 65 8 8 8 62 4 5 6 09 8 8 460 8 4 222 0 254 6 2 65 55 70 007-OSY 80 4 8 867 8 7 8 479 4 5 6 09 8 8 460 8 4 222 0 8 267 7 78 85 84 007-NRS 80 4 8 867 0 4 260 4 5 6 09 8 8 460 8 4 222 0 8 267 7 78 85 84 007QT-FD 80 4 8 867 6 8 62 4 5 6 09 8 8 460 8 4 222 0 8 267 7 78 55 70 U007QT Union Nut Union Tailpiece SIZE (DN) in. mm in. mm 2 5 2 6 25 4 20 6 5 25 6 5 8 422 4 2 20 4 527 2 40 2 2 546 2 50 24 2 622 IMPORTNT: Inquire with governing authorities for local installation requirements

Series 79 Double Check Valve ssemblies Sizes: 2" 2" (5 50mm) Double Check Valve ssemblies 79QT Series 79 Double Check Valve ssemblies are designed to protect drinking water supplies from dangerous cross connections in accordance with national plumbing codes and water authority requirements. This series may be used in only those cross-connections identified by local inspection authorities as non-health hazard applications. Check with local authority having jurisdiction regarding vertical orientation, frequency of testing or other installation requirements. Series 79 meets the requirements of SSE Std. 05 and WW Std. C50. Features Manufactured from bronze alloy Separate access, top entry check valve design Reversible seat disc rubber, extends check valve life Chloramine resistant elastomers Replaceable seats and seat discs Compact design Top mounted screwdriver slotted ball valve test cocks Low pressure drop 2" " (5 25mm) have Tee handles No special tools required for servicing Plastic on plastic check guiding reduces potential binding due to mineral deposits Models Suffix: S bronze strainer LF without shutoff valves L locking handle ball valves S stainless steel ball valve handles C 2 2" inlet/outlet fire hydrant fittings (2" valve) QT quarter-turn ball valves C&T testcock caps and tethers Prefix: U union connections QT street elbows with quarter-turn ball valves Pressure-Temperature Temperature Range: F 80 F (0.5 C 82 C) Maximum Working Pressure: 75psi (2. bar) Materials Body: Bronze Elastomers: Chloramine resistant silicone and EPDM Check seats: PPO Disc older: PPO pprovals 05 WW Std C50 compliant First Check ssembly Test Cocks Second Check ssembly 4 For additional information, request literature ES-79. See Flow Charts on p. 69

D N C B 79QT, 79QT-S M E G F SIZE (DN) DIMENSIONS STRINER DIMENSIONS WEIGT B C D E(LF) F G M N 79QT 79QT-S in. mm in. mm in. mm in. mm in. mm in. mm in. mm in. mm in. mm in. mm in. mm lbs. kgs. lbs. kgs. 2 5 9 9 6 242 6 94 2 5 6 7 2 9 6 8 5 6 47 2 7 6 62 6 4 4 9 8 5 2 4 70 2.8..8.7 4 20 2 8 07 4 4 08 2 88 5 7 6 9 7 6 95 8 79 2 6 52 6 27 5 8 4 6 8 4.7 2. 6.4 2.9 25 4 6 76 4 9 6 6 7 8 98 9 2 495 9 5 8 244 4 95 2 7 6 62 5 6 2 8 54 4 95 7.4.4 9.4 4. 4 2 8 5 6 480 6 8 56 5 8 29 24 6 60 6 297 4 4 08 2 5 8 67 5 8 4 2 2 64 4 7 6 4.0 6. 8.0 8. 2 40 8 5 6 480 6 8 56 5 8 29 25 4 640 6 297 4 4 2 8 79 5 8 4 76 4 7 8 24 6. 7. 9.9 9.0 2 50 2 6 58 7 6 79 5 5 8 42 28 5 6 75 8 40 5 8 7 7 6 87 5 6 49 9 6 90 5 5 6 5 25.7.6.4 5.2 N D C B Double Check Valve ssemblies M E G F U79QT, U79QT-S SIZE (DN) DEMENSIONS STRINER DIMENSIONS WEIGT B C D E (LF) F G M N U79QT U79QT-S in. mm in. mm in. mm in. mm in. mm in. mm in. mm in. mm in. mm in. mm in. mm lbs. kgs. lbs. kgs. 2 5 5 6 402 4 9 6 6 7 8 98 8 6 478 8 289 76 6 4 5 6 8 5 2 4 70 7.4.4 8.4.8 4 20 6 4 42 4 9 6 6 7 8 98 9 5 8 498 5 6 287 8 86 2 6 52 5 6 5 8 4 6 8 7.9.6 9.7 4.4 25 7 5 6 49 4 9 6 6 7 8 98 22 558 4 297 4 95 2 7 6 62 5 6 2 8 54 4 95 8.9 4.0 0.9 5.0 4 2 20 7 8 50 6 8 56 5 8 29 26 660 5 8 90 4 4 08 2 5 8 67 5 8 4 2 2 64 4 7 6 7.6 8.0 2.6 9.8 2 40 2 9 6 547 6 8 56 5 8 29 27 7 8 708 5 8 90 4 4 2 8 79 5 8 4 76 4 7 8 24 9.8 9.0 2.5 0.7 2 50 24 7 6 62 7 6 79 5 5 8 42 2 6 87 6 4 425 5 8 7 7 6 87 5 6 49 9 6 90 5 5 6 5 0.0.6 7.7 7. D B E C 79QT G F SIZE (DN) DIMENSIONS WEIGT B C D E (LF) F G in. mm in. mm in. mm in. mm in. mm in. mm in. mm in. mm in. mm lbs. kgs. 2 5 7 7 8 200 5 6 84 2 5 6 7 2 5 6 7 5 6 47 2 7 6 62 6 4 4 9.4.5 4 20 7 6 40 4 6 2 4 9 6 6 2 98 7 6 95 8 79 2 6 52 6 27 5.7 2.6 25 2 6 22 5 27 4 8 0 7 8 98 9 5 8 244 4 95 2 7 6 62 5 6 8.9 4.0 4 2 5 /6 86 5 6 44 5 6 44 5 8 29 6 297 4 4 08 2 5 8 67 5 8 4 5.7 7. 2 40 5 6 40 6 /6 56 6 6 56 5 8 29 6 297 4 4 2 8 79 5 8 4 8.4 8. 2 50 7 8 4 5 8 68 6 9 6 67 5 5 8 42 8 40 5 8 7 7 6 87 5 6 49 29.0. IMPORTNT: Inquire with governing authorities for local installation requirements 5

Series 757DCD, 757NDCD Double Check Detector ssemblies Sizes: 2 2" 0" (65 250mm) 2 Double Check Detector ssemblies 757DCD OSY 757DCD BFG 757NDCD OSY Series 757DCD, 757NDCD Double Check Detector ssemblies are used to prevent backflow of pollutants that are objectionable but not toxic, from entering the potable water supply system. This Series can be applied, where approved by the local authority having jurisdiction, on non-health hazard installations. The 757DCD, 757NDCD may be installed under continuous pressure service and may be subjected to backpressure. The 757DCD, 757NDCD are used primarily on fire line sprinkler systems when it is necessary to monitor unauthorized use of water. Features Extremely compact design 70% lighter than traditional designs Groove fittings allow integral pipeline adjustment Patented tri-link checks provide lowest pressure loss Unmatched ease of serviceability vailable with grooved butterfly valve shutoffs May be used for horizontal, vertical or N pattern installations Replaceable check disc rubber Materials ousing & Sleeve: 04 (Schedule 40) Stainless Steel Elastomers: EPDM, Silicone and Buna-N Tri-link Checks: Noryl, Stainless Steel Check Discs: Reversible Silicone or EPDM Test Cocks: Bronze Body Nickel Plated Pins & Fasteners: 00 Series Stainless Steel Springs: Stainless Steel Pressure-Temperature Temperature Range: F 0 F (0.5 C 4 C) Maximum Working Pressure: 75psi (2. bar) # Testcock Tri-link Check Modules Quick ccess Sleeve Corrosion Resistant 00 Series Stainless Steel Body and Sleeve Replaceable Seat Discs 6 For additional information, request literature ES-757DCD/757NDCD. See Flow Charts on p. 7

Dimensions Weights C (open) J I D G P 2 757DCD, 757NDCD SIZE (DN) DIMENSIONS (PPROX.) WEIGT C (OSY) D G I J P 757DCD 757NDCD in. mm in. mm in. mm in. mm in. mm in. mm in. mm in. mm in. mm lbs. kgs. lbs. kgs. 2 2 65 787 6 8 46 2 89 29 6 78 22 559 5 2 9 8 6 22 6 5 9 6 47 67 80 6 805 8 7 8 479 6 94 0 4 768 22 4 578 7 8 45 9 6 2 4 2 68 59 72 72 78 4 00 6 856 22 4 578 4 02 88 24 60 8 2 470 9 5 6 252 5 6 86 75 79 98 90 6 50 4 2 05 0 8 765 5 2 40 44 4 7 4 857 2 6 589 6 2 9 48 09 40 50 59 8 200 50 270 7 4 959 6 6 70 54 8 75 40 5 8 02 27 7 6 697 5 6 99 2 6 58 494 224 569 258 0 250 57 2 460 45 4 62 8 6 208 66 676 50 270 2 2 826 7 5 6 440 24 60 795 6 965 48 C D J I Double Check Detector ssemblies 757DCD BFG, 757NDCD BFG G P SIZE (DN) DIMENSIONS (PPROX.) WEIGT C D G I J P 757DCDBFG 757NDCD BFG in. mm in. mm in. mm in. mm in. mm in. mm in. mm in. mm in. mm lbs. kgs. lbs. kgs. 2 2 65 28 7 8 20 2 89 29 7 8 759 22 559 4 5 6 79 8 6 22 0 70 2 78 5 80 28 2 724 8 5 6 2 6 94 0 6 779 22 4 578 5 7 6 92 9 6 2 2 4 68 8 7 4 00 29 6 74 8 5 6 227 6 94 5 6 8 24 60 6 4 42 9 5 6 252 4 56 75 4 98 44 6 50 6 2 927 0 254 5 27 4 6 097 4 857 9 6 500 6 2 4 2 68 59 7 78 8 200 4 092 2 4 6 2 65 5 6 297 40 5 8 02 2 5 6 592 5 6 99 8 6 462 275 25 5 59 Models Suffix OSY - UL/FM outside stem and yoke resilient seated gate valves OSY FxG - flanged inlet gate connection and grooved outlet gate connection OSY GxF - grooved inlet gate connection and flanged outlet gate connection OSY GxG - grooved inlet gate connection and grooved outlet gate connection BFG - UL/FM grooved gear operated butterfly valves with tamper switch for sizes 2 2" 8" (65 200mm) vailable with grooved NRS gate valves - consult factory Post indicator plate and operating nut available - consult factory Consult factory for dimensions pprovals 048 (BFG & OSY only) B64.5 IMPORTNT: Inquire with governing authorities for local installation requirements 7

Series 757NaDCD Double Check Detector ssemblies Sizes: 2 2" 6" (65 50mm) 2 Double Check Detector ssemblies 757NaDCD OSY Series 757NaDCD Double Check Detector ssemblies are used to prevent backflow of pollutants that are objectionable but not toxic, from entering the potable water supply system. These models can be applied, where approved by the local authority having jurisdiction, on non-health hazard installations. The 757NaDCD may be installed under continuous pressure service and may be subjected to backpressure. The 757NaDCD are used primarily on fire line sprinkler systems when it is necessary to monitor unauthorized use of water. Features Extremely compact design 70% lighter than traditional designs Groove fittings allow integral pipeline adjustment Patented bi-link checks provide lowest pressure loss Unmatched ease of serviceability vailable with grooved butterfly valve shutoffs Used for N pattern installations Replaceable check disc rubber Materials ousing & Sleeve: 04 (Schedule 40) Stainless Steel Elastomers: EPDM and Buna-N Bi-link Checks: Noryl, Stainless Steel Check Discs: Reversible EPDM Test Cocks: Bronze Body Nickel Plated Pins & Fasteners: 00 Series Stainless Steel Springs: Stainless Steel Pressure-Temperature Temperature Range: F 0 F (0.5 C 4 C) Maximum Working Pressure: 75psi (2. bar) # Testcock Bi-link Check Modules Quick ccess Sleeve Corrosion Resistant 00 Series Stainless Steel Body and Sleeve Replaceable Seat Discs 8 For additional information, request literature ES-757aDCD/757NaDCD. See Flow Charts on p. 72

Dimensions Weights J I G P 2 757NaDCD SIZE (DN) DIMENSIONS (PPROX.) WEIGT G I J P 757NaDCD in. mm in. mm in. mm in. mm in. mm in. mm lbs. kgs. 2 2 65 29 6 78 22 559 5 2 9 8 6 22 6 5 47 67 80 0 4 768 22 4 578 7 8 45 9 6 2 4 2 68 72 78 4 00 88 24 60 8 2 470 9 5 6 252 5 6 86 98 90 6 50 44 4 7 4 857 2 6 589 6 2 9 48 50 59 Note: For 2 /2" 6" horizontal/vertical installation, see page 6 7. J I Double Check Detector ssemblies G P 757NaDCD BFG SIZE (DN) DIMENSIONS (PPROX.) WEIGT G I J P 757aNDCD BFG in. mm in. mm in. mm in. mm in. mm in. mm lbs. kgs. 2 2 65 29 7 8 759 22 559 4 5 6 79 8 6 22 0 78 5 80 0 6 779 22 4 578 5 7 6 92 9 6 2 2 4 8 7 4 00 5 6 8 24 60 6 4 42 9 5 6 252 4 56 98 44 6 50 4 6 097 4 857 9 6 500 6 2 4 2 68 7 78 Note: For 2 /2" 6" horizontal/vertical installation, see page 6 7. Models Suffix OSY - UL/FM outside stem and yoke resilient seated gate valves OSY FxG - flanged inlet gate connection and grooved outlet gate connection OSY GxF - grooved inlet gate connection and flanged outlet gate connection OSY GxG - grooved inlet gate connection and grooved outlet gate connection BFG - UL/FM grooved gear operated butterfly valves with tamper switch vailable with grooved NRS gate valves - consult factory Post indicator plate and operating nut available - consult factory Consult factory for dimensions pprovals 048 (BFG & OSY only) B64.5 IMPORTNT: Inquire with governing authorities for local installation requirements 9

Series 774DCD Double Check Detector ssemblies 774DCD: Sizes 2 2" 2" (65 00mm) 2 Double Check Detector ssemblies 774DCD OSY Series 774DCD Double Check Detector ssemblies are designed for use in accordance with water utility containment requirements. It is mandatory to prevent the reverse flow of fire protection system substances, i.e., glycerin wetting agents, stagnant water and water of non-potable quality from being pumped or siphoned into the potable water supply. These models can be applied, where approved by the local authority having jurisdiction, on non-health hazard installations. Features Patented torsion spring check valve provides low head loss Short lay length is ideally suited for retrofit installations Stainless steel body is half the weight of competitive designs reducing installation and shipping cost Stainless steel construction provides long term corrosion protection and maximum strength Single top access cover with two-bolt grooved style coupling for ease of maintenance Thermoplastic and stainless steel check valves for trouble-free operation No special tools required for servicing Compact construction allows for smaller vaults and enclosures Furnished with 5 8" x 4" (6 x 9mm) bronze meter (gpm or cfm) Detects underground leaks and unauthorized water use May be installed in horizontal or vertical flow up position Materials ll internal metal parts: 00 Series stainless steel Main valve body: 00 Series stainless steel Check assembly: Noryl Pressure Temperature Temperature Range: to 0 F (0.5 C 4 C) continuous Maximum Working Pressures: 75psi (2. bar) 774DCD Bypass Meter Testcock Cover Testcock Grooved Coupling Bypass Double Check Valve Laser Cut/ Polished Cam rm 20 For additional information, request literature ES-774DCD or ES-774XDCD. See Flow Charts on p. 7 74

Dimensions Weights C (Open) G 774DCD L SIZE (DN) DIMENSIONS (PPROX.) WEIGT 774DCD 774DCD C (open) D G L P w/gates w/o Gates in. mm in. mm in. mm in. mm in. mm in. mm in. mm lb. kg. lb. kgs. 2 2 65 8 965 6 8 46 2 89 0 254 22 559 2 2 8 55 70 68 80 8 965 8 7 8 479 4 95 0 254 22 559 0 20 04 70 2 4 00 40 06 22 4 578 4 2 4 0 254 22 559 4 2 68 240 09 7 6 50 48 2 22 0 8 765 5 2 40 5 8 27 2 699 5 2 94 90 77 20 54 8 200 52 2 4 7 4 959 6 4 7 5 8 29 2 749 8 4 464 572 259 80 82 0 250 55 2 40 45 4 62 8 200 5 8 29 2 749 9 2 495 774 5 90 86 2 00 57 2 46 5 8 49 9 2 24 5 8 29 2 749 2 5 044 474 220 00 D P 2 Double Check Detector ssemblies Models Suffix LF - without shutoff valves OSY - UL/FM outside stem & yoke resilient seated gate valves CFM - cubic feet per minute meter GPM - gallons per minute meter OSY FxG - flanged inlet gate connection and grooved outlet gate connection OSY GxF - grooved inlet gate connection and flanged outlet gate connection OSY GxG - grooved inlet gate connection and grooved outlet gate connection vailable with grooved NRS gate valves - consult factory Post indicator plate and operating nut available - consult factory Consult factory for dimensions pprovals 2 2" 0" only (65-25mm) 048 (OSY only) (OSY only) For additional approvals consult factory Flange dimension in accordance with WW Class D IMPORTNT: Inquire with governing authorities for local installation requirements 2

Series 709DCD Double Check Detector ssemblies Sizes: " 0" (80 250mm) 2 Double Check Detector ssemblies 709DCD OSY Series 709DCD Double Check Detector ssemblies are designed exclusively for use in accordance with water authority containment requirements on nonhealth hazard applications. It is mandatory to prevent the reverse flow of fire protection system substances, i.e. glycerin wetting agents, stagnant water and water of non-potable quality from being pumped or siphoned into the potable water line. Benefits: detects leaks, with emphasis on the cost of unaccountable water; incorporates a meter which allows the water utility to: Detect leaks underground that historically create great annual cost due to waste. It provides a detection point for unauthorized use. It can help locate illegal taps. Modular check design concept facilitates maintenance and assembly access. ll sizes are standardly equipped with resilient seated OSY shutoff valves, 5 8" x 4" (6 x 9mm ) meter and ball type test cocks. Features Materials Test Cock Body construction fused epoxy coated cast iron Replaceable bronze seats Maximum flow at low pressure drop Compact for economy combined with performance Design simplicity for easy maintenance Furnished with 5 8" x 4" (6 x 9mm) meter Model 25, bronze No special tools required for servicing Body: Epoxy coated cast iron Seat and Disc older: Replaceable bronze Trim: Stainless steel Check Valve Discs: Durable, tightseating rubber Test Cocks: Bronze Pressure Temperature Temperature Range: F 0 F (0.5 C 4 C) continuous, 40 (60 C) intermittent Maximum Working Pressure: 75psi (2. bar) Check ssembly Module Cover Disc Seat 22 For additional information, request literature ES-709DCD. See Flow Charts on p. 68 69

Dimensions Weights C (open) 2 709DCD L SIZE (DN) DIMENSIONS (PPROX.) WEIGT C D L R T in. mm in. mm in. mm in. mm in. mm in. mm in. mm lbs. kgs. 80 40 06 8 7 8 479 4 95 24 60 4 56 76 90 86 4 00 52 2 22 4 578 4 2 4 4 864 5 8 6 52 40 8 6 50 6 4 607 0 8 765 5 2 40 42 4 07 6 406 7 2 9 727 0 8 200 75 905 7 4 959 6 5 8 68 52 2 7 42 9 229 27 602 0 250 90 2286 45 4 62 8 20 64 626 8 457 0 4 260 209 949 D R T Double Check Detector ssemblies Models Suffix OSY - UL/FM outside stem & yoke resilient seated gate valves CFM - cubic feet per minute GPM - gallons per minute meter LF - without shutoff valves (4" 0") (00 250mm) pprovals 048 pproved by the foundation for Cross- Connection Control and ydraulic Research at the University of Southern California (Sizes 4" 0" (00 250mm) approved for horizontal and vertical flow up. Size " (80mm) approved for horizontal only.) Factory Mutual approved 4" 0" (00-250mm) vertical flow up IMPORTNT: Inquire with governing authorities for local installation requirements 2

Series 007DCD Double Check Detector ssemblies Sizes: 2" " (50 80mm) 2 Double Check Detector ssemblies 007DCD OSY Series 007DCD Double Check Detector ssemblies are designed exclusively for use in accordance with water utility authority non-health hazard containment requirements. It is mandatory to prevent the reverse flow of fire protection system substances, i.e., glycerin wetting agents, stagnant water and water of nonpotable quality from being pumped or siphoned into the potable water line. Benefits: Detects leaks... with emphasis on the cost of unaccountable water; incorporates a meter which allows the water utility to: Detect underground leaks that historically create great annual cost due to waste. Provide a detection point for unauthorized use. It can help locate illegal taps. Modular check design concept facilitates maintenance and assembly access. ll sizes are standardly equipped with resilient seated OSY shutoff valves and 5 8" x 4" (6 x 9mm) meter. Features Fused epoxy coated cast iron unibody 2 2" & " (65-80mm) Replaceable bronze seats Maximum flow at low pressure drop Compact for ease of installation Design simplicity for easy maintenance No special tools required for servicing Bronze body ball valve test cocks Modular spring loaded checks Furnished with bronze 5 8" x 4" (6 x 9mm) meter Materials Body: 2" Bronze, 2 2" " (65-80mm) FD approved, epoxy coated castiron unibody Seats: Bronze Discs: Durable, tight-seating silicone Springs: Stainless steel Meter: 5 8" x 4" (6 9mm) bronze Pressure Temperature Temperature Range: F 0 F (0.5 C 4 C) continuous, 40 F (60 C) intermittent Maximum Working Pressure: 75psi (2. bar) Test Cock st Check Module Retainer 2nd Check Module 24 For additional information, request literature ES-007DCD. See Flow Charts on p. 64

Dimensions Weights 2" (50mm) E P B (open) 2 E 2 /2" " (65-80mm) P (2" 007DCD) B (open) Double Check Detector ssemblies E 007DCD SIZE (DN) DIMENSIONS (PPROX.) WEIGT B E P in. mm in. mm in. mm in. mm in. mm lbs. kgs. 2 50 5 8 892 /2 4 6 4 426 2 4 97 44 2 2 65 4 845 6 8 46 6 8 46 2 5 6 64 74 80 4 4 870 8 7 8 479 6 5 8 422 2 5 6 96 89 Models Suffix OSY - UL/FM outside stem & yoke resilient seated gate valves CFM - cubic feet per minute meter GPM - gallons per minute meter LF - without shutoff valves pprovals 048 (2" size only) (OSY only) pproved by the Foundation for Cross- Connection Control and ydraulic Research at the University of Southern California. 2" & 2 2" (50 & 65mm) 007DCD horizontal or vertical flow up position " (80mm) horizontal only IMPORTNT: Inquire with governing authorities for local installation requirements 25

Series 957, 957N, 957Z Reduced Pressure Zone ssemblies Sizes: 2 2" 0" (65 250mm) Reduced Pressure Zone ssemblies Series 957, 957N, 957Z Reduced Pressure Zone ssemblies provide protection to the potable water system from contamination in accordance with national plumbing codes. Series 957, 957N, 957Z are normally used in health hazard applications for protection against backsiphonage or backpressure. Features 957 OSY 957N BFG 957 QT Extremely compact design 70% lighter than traditional designs Groove fittings allow integral pipeline adjustment Patented torsion spring checks provide lowest pressure loss Unmatched ease of serviceability vailable with grooved butterfly valve shutoffs Replaceable check disc rubber Bottom mounted cast stainless steel relief valve 2 2" " sizes available with quarterturn ball valve shutoffs Materials ousing & Sleeve: 04 (Schedule 40) Stainless Steel Elastomers: EPDM, Silicone and Buna-N Torsion Spring Checks: Noryl, Stainless Steel Check Discs: Reversible Silicone or EPDM Test Cocks: Bronze Body Nickel Plated Pins & Fasteners: 00 Series Stainless Steel Springs: Stainless Steel Models Suffix: NRS - non-rising stem resilient seated gate valves OSY - UL/FM outside stem and yoke resilient seated gate valves OSY FxG - flanged inlet gate connection and grooved outlet gate connection OSY GxF - grooved inlet gate connection and flanged outlet gate connection OSY GxG - grooved inlet gate connection and grooved outlet gate connection BFG - UL/FM grooved gear operated butterfly valves with tamper switch. Sizes 2 2" 6" (65 50mm) N and Z patterns only QT - 2 2" " (65 80mm) quarter-turn ball valves vailable with grooved NRS gate valves - consult factory Post indicator plate and operating nut available - consult factory Consult factory for dimensions pprovals 0 (BFG & OSY only) B64.4 # Testcock Torsion Spring Check Modules Quick ccess Sleeve RV Piston ssembly Corrosion Resistant 00 Series Stainless Steel Body and Sleeve Replaceable Seat Discs RV S/S Pressure Temperature Temperature Range: F to 0 F (0.5 C to 4 C) Maximum Working Pressure: 75psi (2. bar) 26 For additional information, request literature ES-957/957N/957Z. See Flow Charts on p. 76 77

Dimensions Weights C (open) J I M D 957 G P SIZE (DN) DIMENSIONS (PPROX.) WEIGT C (OSY) C (NRS) D G I J M P 957NRS 957OSY 957N NRS 957N OSY in. mm in. mm in. mm in. mm in. mm in. mm in. mm in. mm in. mm in. mm in. mm lbs. kgs. lbs. kgs. lbs. kgs. lbs. kgs. 2 2 65 787 6 8 46 9 8 28 6 2 65 29 6 78 22 559 5 2 9 8 6 22 2 9 6 548 9 6 24 8 54 28 58 26 57 6 62 80 6 805 8 7 8 479 0 4 260 6 6 70 0 4 768 22 4 578 7 8 45 9 6 2 2 8 587 0 2 267 4 6 48 67 47 67 6 7 4 00 6 856 22 4 578 2 6 0 7 78 88 24 60 8 2 470 9 5 6 252 26 2 67 6 284 64 74 64 74 87 85 87 85 6 50 4 2 05 0 8 765 6 406 8 2 26 44 4 7 4 857 2 6 589 6 2 2 4 82 5 8 276 25 298 5 7 44 9 54 8 200 50 270 7 4 959 9 5 6 506 9 6 246 54 8 75 40 5 8 02 27 7 6 697 5 6 99 7 8 94 7 6 47 44 200 48 29 56 24 558 25 0 250 57 2 460 45 4 62 2 6 605 6 285 66 676 50 270 2 2 826 7 5 6 440 46 8 78 20 508 72 28 78 9 405 950 4 J I M Reduced Pressure Zone ssemblies 957N BFG, 957Z BFG G P SIZE (DN) DIMENSIONS (PPROX.) WEIGT G I J M P 957N, 957Z in. mm in. mm in. mm in. mm in. mm in. mm in. mm lbs. kgs. 2 2 65 2 2 826 2 2 597 5 2 94 9 2 24 2 6 555 6 00 67 0 80 4 864 24 2 622 6 5 6 44 0 6 256 2 8 587 2 8 08 70 2 4 00 5 5 8 905 26 660 7 6 47 0 5 6 279 24 5 6 64 2 5 8 2 87 9 6 50 46 2 8 5 2 6 908 20 2 52 2 4 28 4 78 5 82 60 7 C D J I M P G P 957 QT SIZE (DN) DIMENSIONS (PPROX.) WEIGT C D G I J M P P in. mm in. mm in. mm in. mm in. mm in. mm in. mm in. mm in. mm in. mm in. mm lbs. kgs. 2 2 65 28 5 6 75 4 7 8 24 6 7 8 74 0 4 768 24 2 622 6 9 6 42 8 289 20 5 6 52 5 6 287 5 6 287 46 2 80 0 6 767 4 6 22 6 7 8 74 0 4 768 24 2 622 7 6 47 4 258 22 6 564 5 6 287 5 6 287 56 25 IMPORTNT: Inquire with governing authorities for local installation requirements 27

Series 994 Reduced Pressure Zone ssemblies Sizes 2 2" 0" (65 250mm) Test Cock Stainless Steel Cover Torsion Spring Grooved Coupling Reduced Pressure Zone ssemblies Dimensions Weights 994 OSY Series 994 Reduced Pressure Zone ssemblies are designed to provide protection of the potable water supply in accordance with national codes. This Series can be used, where approved by the local authority having jurisdiction on health hazard cross-connections. Series 994 features short lay length, lightweight stainless steel body, corrosive resistant stainless steel relief valve, and patented torsion spring check valves. Features Stainless Steel construction provides long term corrosion resistance and maximum strength Stainless Steel body is half the weight of competitive designs reducing installation & shipping costs Short end to end dimensions makes retrofit easy Bottom mounted relief valve reduces clearance requirements when installed against an outside wall Patented torsion spring check valves provides maximum flow at low pressure drop Thermoplastic & stainless steel check valves for trouble-free operation No special tools required for servicing Compact construction allows for smaller enclosures Stainless steel relief valve features a balanced rolling diaphragm to eliminate sliding seals and lower maintenance costs Materials ll internal metal parts: 00 Series stainless steel Main valve body: 00 Series stainless steel Check assembly: Noryl Replaceable Seat Pressure Temperature Temperature Range: F 0 F (0.5 C 4 C), continuous Maximum Working Pressure: 75psi (2. bar) Models Suffix NRS - non-rising stem resilient seated gate valves OSY - UL/FM outside stem & yoke resilient seated gate valves LF - without shutoff valves S - cast iron strainer OSY FxG - flanged inlet gate connection and grooved outlet gate connection OSY GxF - grooved inlet gate connection and flanged outlet gate connection OSY GxG - grooved inlet gate connection and grooved outlet gate connection vailable with grooved NRS gate valves - consult factory Consult factory for dimensions pprovals Stainless Steel Relief Valve Disc Laser Cut/Polished Cam rm N M L G C (Open) D F 0 (OSY only) B64.5 WW pproved by the Foundation for crossconnection Control & ydraulic Research at the University of Southern California 2 /2" 6" (65 50mm) sizes Flange dimension in accordance with WW Class D SIZE (DN) DIMENSIONS (PPROX.) STRINER DIMENSIONS WEIGT C (open) D F G L M N w/gates w/o Gates in. mm in. mm in. mm in. mm in. mm in. mm in. mm in. mm in. mm lb. kg. lb. kgs. 2 2 65 7 940 6 8 49 0 2 267 7 78 0 254 22 559 0 254 6 2 65 48 67 60 27 80 8 965 8 7 8 479 0 2 267 7 2 9 0 254 22 559 0 8 257 7 78 226 0 62 28 4 00 40 06 22 4 578 0 2 267 9 229 0 254 22 559 2 8 08 8 4 20 25 07 65 0 6 50 48 2 22 0 8 765 2 292 279 5 8 27 2 699 8 2 470 2 4 80 72 0 50 8 200 52 2 4 7 4 959 2 2 8 2 4 5 8 29 2 749 2 5 8 549 5 2 94 57 259 79 8 0 250 55 2 40 45 4 62 2 2 8 6 406 5 8 29 2 749 26 660 8 2 470 77 5 89 86 Note: The installation of a drain line is recommended. When installing a drain line, an air gap is necessary. See page 57. IMPORTNT: Inquire with governing authorities for local installation requirements 28 For additional information, request literature ES-994. See Flow Charts on p. 78

Series 994BLT, 994MB ydrant Meter Backflow Preventers 994BLT: Size 2 2" FNPT x " MNPT (65mm FNPT x 80mm MNPT) 994MB: Size 2 2" 7NST x " (65mm 7NST x 80mm) 994MB Series 994 ydrant Backflow Preventers are designed to provide protection to the potable water supply from fire hydrant or other non-permanent connections in accordance with national codes. This Series can be used, where approved by the local authority having jurisdiction on health hazard cross-connections. Series 994 features short lay length, lightweight stainless steel body, corrosive resistant stainless steel relief valve, and patented torsion spring check valves. Features eavy-duty relief valve cover prevents vandalism and protects valve from damage when 994MB is transported to another fire hydrant location In-line flow restrictor protects the meter measuring element and the backflow preventer components from damage due to excessive flow (994MB only) Backflow preventer made from 00 Series stainless steel for corrosion resistance Portable, lightweight design makes device easily transportable between job sites ccurately measures flow (MB Series) and protects the water supply from possible contamination Series 994BLT comes less meter Built-in support leg is adjustable in the field Factory assembled and tested; no field assembly required; eliminates leaks and improper assembly Options (BLT Series) Inlet Modules " (80mm) female or male hydrant thread 2 2" (65mm) female or male hydrant thread 2 2" (65mm) male NPT thread Customer specified Outlet Modules " (80mm) gate w/female or male hose thread 2 2" (65mm) gate w/ female or male hose thread " (80mm) gate valve only, w/" (80mm) INPT thread 2 2" (65mm) gate valve only, w/2 2" (65mm) FNPT Customer specified 994BLT Dimensions Weight MODEL 7 2" lbs. 20 8" WEIGT kgs. 994BLT 62 28 994MB-GPM 66 0 994MB-CFM 66 0 8 4" 9 6" Reduced Pressure Zone ssemblies IMPORTNT: Inquire with governing authorities for local installation requirements See Flow Charts on p. 78 For additional information, request literature ES-994BLT. 29

Series 909 Reduced Pressure Zone ssemblies 909: Sizes: 4", " (20, 25mm) 909M: Sizes: 4", 2", 2" (2, 40, 50mm) Reduced Pressure Zone ssemblies 909 QT Series 909 Reduced Pressure Zone ssemblies are designed to provide superior cross-connection control protection of the potable water supply in accordance with national plumbing codes and containment control for water authority requirements. Series 909 can be utilized in a variety of installations, including health hazard cross-connections in plumbing systems or for containment at the service line entrance. With its exclusive, design incorporating the patented air-in/water-out principle, it provides maximum relief valve discharge during the emergency conditions of combined backsiphonage and back-pressure with both checks fouled. Series 909 is furnished with full port, resilient seated and bronze ball valve shutoffs. Sizes 4" and " (20, 25mm) shutoffs have tee handles. Features Modular design Replaceable bronze seats Compact for installation ease orizontal or vertical (up or down) installation No special tools required for servicing Materials Body: Bronze Seats: Celcon Test cocks: Bronze Model 909W Check seats: Stainless steel Relief valve seats: Stainless steel Check and Relief Valve ssemblies: Durable tight seating, rubber Pressure Temperature Maximum Operating Pressure: 75psi (2. bar) 909 Temperature Range: F 40 F (0.5 C to 60 C) continuous, 80 F (82 C) intermittent 909W Temperature Range: F 20 F (0.5 C 99 C) First Check Supply Pressure Channel to Relief Valve R.P. Zone Relief Valve ssembly Water Outlet Ball Valve Test Cocks ir Inlet ow it Operates The unique relief valve construction incorporates two channels: one for air, one for water. When the relief valve opens, as in the accompanying air-in/water-out diagram, the right-hand channel admits air to the top of the reduced pressure zone, relieving the zone vacuum. The channel on the left then drains the zone to atmosphere. Therefore, if both check valves foul, and simultaneous negative supply and positive back-pressure develop, the relief valve uses the air-in/water-out principle to stop potential backflow. Reduced Pressure Zone Second Check Water Out ir In Celcon is a registered trademark of oescht Celanese. 0 For additional information, request literature ES-909S. See Flow Charts on p. 74

Dimensions Weights L C N B M Suffix C - Fire ydrant Fittings dimension = 2 4" (60mm) 909 E SIZE (DN) DIMENSIONS (PPROX.) STRINER DIMENSIONS WEIGT B C D E L P M N in. mm in. mm in. mm in. mm in. mm in. mm in. mm in. mm in. mm in. mm lbs. kgs. 4 20 4 8 65 8 4 222 4 02 4 4 2 6 4 7 7 5 6 86 7 8 98 6 8 2 4 70 4 6 25 5 8 9 8 4 222 4 02 4 4 2 7 78 7 5 6 86 7 8 98 4 95 76 5 7 4 2 8 2 470 5 8 295 5 2 40 6 2 65 7 2 9 0 8 264 5 4 4 7 6 2 89 40 8 2 40 9 48 5 8 295 5 2 40 6 2 65 7 2 9 0 8 264 5 4 4 7 8 24 4 02 40 8 2 50 9 2 495 5 8 295 5 2 40 6 2 65 7 4 97 0 8 264 5 4 5 5 6 5 5 27 40 8 U909QT Dimensions - with integral body unions (Prefix "U") 4 20 4 5 8 7 8 4 222 4 02 4 4 2 6 4 7 7 5 6 86 7 8 98 6 8 2 4 70 4 6.4 25 5 5 8 97 8 4 222 4 02 4 4 2 7 78 7 5 6 86 7 8 98 4 95 76 5 6.8 FE909QT Dimensions - with flanged adapter ends (Prefix "FE") 4 2 9 48 5 8 295 5 2 40 6 2 65 7 2 9 0 8 264 5 4 4 7 6 2 89 40 8. 2 40 9 4 502 5 8 295 5 2 40 6 2 65 7 2 9 0 8 264 5 4 4 7 8 24 4 02 40 8. 2 50 2 5 5 8 295 5 2 40 6 2 65 7 4 97 0 8 264 5 4 5 5 6 5 5 27 40 8. D P Reduced Pressure Zone ssemblies Models Suffix QT - quarter-turn ball valves S - bronze strainer W - stainless steel check modules for hot and harsh water conditions LF - without shutoff valves L - locking handle ball valves (open position) C - inlet/outlet fire hydrant fitting (2" only) PC - polymer coating Prefix C - clean and check strainer - 4" and " only (20 and 25mm) U - union connections - 4" and " only (20 and 25mm) FE - flanged adapter ends - 4", 2", 2" only (2, 40, 50mm) pprovals 0 WW Listed by IPMO Listed by SBCCI pproved by the Foundation for Cross- Connection Control and ydraulic Research at the University of Southern California. orizontal and vertical flow-up USC approval on 4" and " sizes (models 909QT, 909PCQT, and U909QT). Note: The installation of a drain line is recommended. When installing a drain line, an air gap is necessary. See page 57. IMPORTNT: Inquire with governing authorities for local installation requirements

Series 909 Reduced Pressure Zone ssemblies Sizes: 2 2" 0" (65 250mm) Reduced Pressure Zone ssemblies 909 OSY Series 909 Reduced Pressure Zone ssemblies are designed to provide crossconnection control protection of the potable water supply in accordance with national plumbing codes. This Series can be utilized in a variety of installations, including health hazard cross-connections in plumbing systems or for containment at the service line entrance. Its exclusive patented relief valve design, incorporating the air-in/water-out principle, provides substantially improved relief valve discharge performance during the emergency conditions of combined backsiphonage and backpressure with both checks fouled. Features Replaceable seats Stainless steel internal parts No special tools required for servicing Captured spring check assemblies Fused epoxy coated & lined checks Industrial strength sensing hose Field reversible relief valve ir-in/water-out relief valve design provides maximum capacity during emergency conditions Materials Check Valve Bodies: FD epoxy coated cast iron or bronze Seats: Bronze Trim: Stainless steel Relief Valve Body: 2 2" " (60 80mm) bronze 4" 0" (00 250mm) FD epoxy coated cast iron Test Cocks: Bronze body ball valve Pressure Temperature Temperature Range: F 0 F (0.5 C 4 C) continuous, 40 F (60 C) intermittent Maximum Working Pressure: 75psi (2. bar) st Check Module ssembly Pipe Line Center Relief Valve Body Flange Relief Valve 2nd Check Module ssembly Relief Valve Seat Relief Valve Piston Relief Valve Piston ssembly Wiper Seal Bottom Plug Spring ssembly ow it Operates The unique relief valve construction incorporates two channels: one for air, one for water. When the relief valve opens, as in the accompanying air-in/water-out diagram, the right-hand channel admits air to the top of the reduced pressure zone, relieving the zone vacuum. The channel on the left then drains the zone to atmosphere. Thus, should both check valves foul, and simultaneous negative supply and positive back pressure develop, the relief valve uses the air-in/water-out principle to stop potential backflow. Water Out ir In 2 For additional information, request literature ES-909L. See Flow Charts on p. 74-75

Dimensions Weights M U C (open) OUTLET N N L D R T 909 SIZE (DN) DIMENSIONS (PPROX.) WEIGT C clearance for check (OSY) (NRS) D L U R R (QT) T NRS OSY QT in. mm in. mm in. mm in. mm in. mm in. mm in. mm in. mm in. mm in. mm in. mm lbs. kgs. lbs. kgs. lbs. kgs. 2 2 65 4 4 048 20 5 8 524 6 8 46 9 8 28 5 4 26 8 66 279 4 02 6 406 9 6 20 95 88.4 98 89.8 82 82.6 80 42 4 07 2 4 540 8 7 8 479 0 4 260 5 4 26 8 66 279 5 27 6 406 9 6 20 225 02 20 04 90 86 4 00 55 8 400 27 5 8 702 22 4 578 2 6 0 6 52 7 940 4 56 6 52 9 4 502 4 8 65 455 206 470 2 52 60 6 50 65 2 664 2 4 82 0 8 765 6 406 6 52 44 2 0 6 406 279 26 660 4 8 65 78 26 798 62 762 46 8 200 78 2 2000 9 8 000 7 4 959 9 5 6 506 9 4 248 55 4 40 2 5 4 286 4 286 9 4 489 50 62 456 660 2286 07 0 250 9 5 8 278 46 7 8 90 45 4 62 2 6 605 9 4 248 67 8 7 2 5 2 2 8 2 2 8 2 5 260 980 220 0 76 685 UL, FM approved backflow preventers must include UL/FM approved OSY gate valves. Strainer Dimensions SIZE (DN) DIMENSIONS (PPROX.) WEIGT M N N in. mm in. mm in. mm in. mm lbs. kgs. 2 2 65 0 254 0 254 6 2 65 28 2.7 80 0 8 257 0 254 7 78 4 5.4 4 00 2 8 08 2 05 8 4 20 60 27 6 50 8 2 470 20 508 2 4 60 8 200 2 5 8 549 22 4 578 5 2 94 247 2 0 250 26 660 28 7 8 2 470 70 68 Dimension required for screen removal Reduced Pressure Zone ssemblies Models Suffix LF - without shutoff valves NRS - non-rising stem resilient seated gate valves OSY - UL/FM outside stem and yoke resilient seated gate valves BB - bronze body QT - quarter-turn ball valves QT-FD - FD approved coated quarterturn ball valves S - cast iron strainer S-FD - FD epoxy coated strainer pprovals 0 B64.4 WW IPMO PS, SBCCI (Standard Plumbing Code) pproved by the Foundation for Cross- Connection Control and ydraulic Research at the University of Southern California. Note: Relief valve section is reversible, therefore, can be on either side and is furnished standardly as shown Note: The installation of a drain line is recommended. When installing a drain line, an air gap is necessary. See page 57. IMPORTNT: Inquire with governing authorities for local installation requirements

Series 009 Reduced Pressure Zone ssemblies Sizes: 4" " (8 80mm) Reduced Pressure Zone ssemblies Series 009 Reduced Pressure Zone ssemblies are designed to protect potable water supplies in accordance with national plumbing codes and water authority requirements. This Series can be used in a variety of installations, including the prevention of health hazard cross-connections in piping systems or for containment at the service line entrance. The 009 Series features two in-line, independent check valves, captured springs and replaceable check seats with an intermediate relief valve. Its compact modular design facilitates easy maintenance and assembly access. Sizes 4" " (8 25mm) shutoffs have tee handles. Features 009 QT U009 QT 009M2 QTC Single access cover and modular check construction for ease of maintenance Top entry - all internals immediately accessible Captured springs for safe maintenance Internal relief valve for reduced installation clearances Replaceable seats for economical repair Bronze body construction for durability - 4" 2" (8 50mm) Fused epoxy coated cast iron body - 2 2" and " (65 and 80mm) Ball valve test cocks - screwdriver slotted - 4" 2" (8 50mm) Large body passages provide low pressure drop Compact, space saving design No special tools required for servicing Materials Sizes 4" 2" (8 50mm) Body: Bronze Check and Relief Valve Discs: Silicone rubber Check Seats: Replaceable polymer Relief Valve seat: Removable stainless steel Cover Bolts: Stainless steel Sizes 2 2" " (65 80mm) Body: FD approved epoxy coated cast iron Seats: Bronze Relief Valve Seat and Trim: Stainless steel Test Cocks: Bronze Pressure Temperature Temperature Range: 4" 2" (8 50mm) F 80 F (0.5 C 82 C) 2 2" " (65 80mm) F 0 F (0.5 C 4 C) continuous, 40 F (60 C) intermittent Maximum Working Pressure: 75psi (2. bar) Test Cock No. 2 Ball Type Test Cocks st Check Module ssembly Test Cock No. Relief Valve ssembly Water Outlet 2nd Check Module ssembly Test Cock No. 4 R.P. Zone 4 For additional information, request literature ES-009. See Flow Charts on p. 65-66

Dimensions Weights C B N D L M Suffix C - Fire ydrant Fittings dimension = 25 6 (67mm) 009 4" 2" (8 50mm) SIZE (DN) DIMENSIONS (PPROX.) STRINER DIMENSIONS WEIGT B C D L M N in. mm in. mm in. mm in. mm in. mm in. mm in. mm in. mm lbs. kg. 4 8 0 250 4 5 8 7 8 86 4 2 5 2 40 2 8 60 2 2 64 5 2 8 0 0 250 4 5 8 7 8 86 4 2 5 2 40 2 8 60 2 2 64 5 2 2 5 0 250 4 5 8 7 8 86 4 2 5 2 40 2 4 70 2 4 57 5 2 4 20 0 4 27 5 27 2 89 2 8 6 4 7 6 8 2 4 70 6 25 6 4 425 5 2 40 76 2 2 64 9 2 24 4 95 76 2 5 4 2 7 8 4 50 2 89 2 2 64 8 289 4 7 6 2 89 5 6 2 40 7 7 8 454 6 50 2 89 2 2 64 8 7 8 24 4 02 6 7 2 50 2 8 54 7 4 97 4 2 4 4 8 2 4 5 5 6 5 5 27 0 N U C (Open) D Reduced Pressure Zone ssemblies L 009 2 2" and " (65 80mm) M E R MODEL NO. SIZE (DN) DIMENSIONS (PPROX.) STRINER DIMENSIONS WEIGT C D E L R U M N in. mm in. mm in. mm in. mm in. mm in. mm in. mm in. mm in. mm in. mm lbs. kgs. 009LF 2 2 65 5 4 8 8 460 0 5 8 270 0 254 6 2 65 76 4 009OSY 2 2 65 4 845 6 8 46 5 4 6 8 46 8 8 460 7 4 97 0 5 8 270 0 254 6 2 65 66 75 009NRS 2 2 65 4 845 9 8 28 5 4 6 8 46 8 8 460 7 4 97 0 5 8 270 0 254 6 2 65 89 86 009QT 2 2 65 4 845 6 52 5 4 6 8 46 8 8 460 7 4 97 0 5 8 270` 0 254 6 2 65 50 68 009LF 80 5 4 8 8 460 0 5 8 270 0 8 257 7 78 76 4 009OSY 80 4 4 870 8 7 8 470 5 4 6 5 8 422 8 8 460 8 4 222 0 5 8 270 0 8 257 7 78 98 90 009NRS 80 4 4 870 0 4 260 5 4 6 5 8 422 8 8 460 8 4 222 0 5 8 270 0 8 257 7 78 9 87 009QT 80 4 4 870 7 78 5 4 6 5 8 422 8 8 460 8 4 222 0 5 8 270 0 8 257 7 78 58 7 Models Sizes 4" 2" (8 50mm) Suffix QT - quarter-turn ball valves S - bronze strainer LF - without shutoff valves QT - elbow fittings for 60 rotation ( 4" 2" only) (20 50mm only) PC - internal polymer coating L - locking handle ball valves (open position) S - stainless steel ball valve handles C - 2 2" (65mm) inlet/outlet fire hydrant fitting 2" (50mm) valve Prefix C - clean and check strainer ( 4" " only) (20 25mm only) U - union connections SS - 6 stainless steel body and stainless steel ball valve, 4" " (8 25mm only) Sizes 2 2" and " (65 and 80mm) Suffix NRS - non-rising stem resilient seated gate valves OSY - UL/FM outside stem & yoke resilient seated gate valves LF - without shutoff valves S - bronze strainer S-FD - FD epoxy coated strainer QT-FD - FD epoxy coated quarterturn ball valves pprovals 0 WW, IPMO pproved by the Foundation for Cross-Connection Control and ydraulic Research at the University of Southern California. pproval models QT, QT, PC, U, NRS, OSY. UL Classified 4" 2" (20 50mm) (LF models only), 2 2" and " (65 80mm) with OSY gate valves. Note: The installation of a drain line is recommended. When installing a drain line, an air gap is necessary. See page 57. IMPORTNT: Inquire with governing authorities for local installation requirements 5

Series 99 Reduced Pressure Zone ssemblies Sizes: 4" 2" (20 50mm) Reduced Pressure Zone ssemblies Series 99 Reduced Pressure Zone Backflow ssemblies are designed to protect potable water supplies in accordance with national plumbing codes and water authority requirements. This series can be used in a variety of installations, including the prevention of health hazard cross-connections or for containment at the service line entrance. This series features two poppet style check valves, replaceable check seats, with an intermediate relief valve. Its compact modular design facilitates easy maintenance and assembly access. Sizes 4" " (20 25mm) shutoffs have tee handles. Features 99QT Models Test Cocks Separate access covers for the check valves and relief valve for ease of maintenance Top entry-all check internals easily accessible ll rubber elastomers of chloramine resistant material Check valve poppet assemblies are fully guided by innovative plastic seat guide Replaceable push-in check valve and relief valve seats eliminates threads from the water way EZ twist relief valve cover-quarter turn locking joint captures the spring load during repair to facilitate disassembly Innovative check valve plastic cover bushing provides trouble free guiding of the check valve poppet Bottom mounted relief valve provides reduced installation clearances Compact, space saving design No special tools required for servicing Suffix: QT quarter-turn ball valves S bronze strainer LF without shutoff valves QT elbow fitting for 60º rotation ZQT inlet & outlet flow up Prefix: U union connections Materials Body: Bronze Discs: Silicone rubber Check Seats: Replaceable polymer Cover Bolts: Stainless steel Pressure Temperature Temperature Range: ºF 80ºF (0.5ºC 82ºC) Maximum Working Pressure: 75psi (2. bar) First Check ssembly Relief Valve Second Check ssembly Top mounted test cocks for ease in testing and reduced installation clearances pprovals Standardly furnished with NPT body connections 0 6 For additional information, request literature ES-99. See Flow Charts on p. 76

Dimensions Weights D M C N B 99QT, 99QT-S E G F SIZE (DN) DIMENSIONS STRINER DIMENSIONS WEIGT B C D E (LF) F G M N 99QT 99QT-S in. mm in. mm in. mm in. mm in. mm in. mm in. mm in. mm in. mm in. mm in. mm lbs. kgs. lbs. kgs. 4 20 2 8 07 7 7 6 88 2 88 5 2 9 7 6 95 5 8 92 2 6 52 9 6 40 5 8 4 6 8 8..7 0.0 4.5 25 4 2 68 8 202 7 8 98 9 6 487 9 6 2 4 02 2 7 6 62 9 6 40 2 8 54 4 95.8 5.4.8 6. 4 2 8 8 46 7 6 290 5 8 29 2 4 59 6 297 5 8 0 2 5 8 67 2 2 64 2 2 64 4 7 6 22. 0. 26..9 2 40 8 4 476 7 6 290 5 8 29 25 6 67 6 297 5 5 8 4 8 79 2 2 64 76 4 7 8 24 28. 2.8 2.0 4.5 2 50 2 6 55 2 6 07 5 5 8 42 28 6 72 8 40 5 5 6 5 7 6 87 2 2 64 9 6 90 5 5 6 5 7. 6.9 45.0 20.4 U99QT, U99QT-S N M D E C B G F Reduced Pressure Zone ssemblies SIZE (DN) DIMENSIONS STRINER DIMENSIONS WEIGT B C D E (LF) F G M N U99QT U99QT-S n. mm in. mm in. mm in. mm in. mm in. mm in. mm in. mm in. mm in. mm in. mm lbs. kgs. lbs. kgs. 4 20 6 5 6 40 8 6 204 7 8 98 20 5 6 55 2 292 5 8 92 2 6 52 9 6 40 5 8 4 9 6 8.4 6. 5. 6.9 25 7 8 45 8 6 204 7 8 98 2 6 554 4 297 4 02 2 7 6 62 9 6 40 2 8 54 4 95. 6.0 5. 6.9 4 2 20 5 6 52 7 6 290 5 8 29 26 6 662 5 8 90 5 8 0 2 5 8 67 2 2 64 2 2 64 4 7 6 25.9.8 29.9.6 2 40 2 9 6 547 7 6 290 5 8 29 27 7 8 708 5 8 90 5 5 8 4 8 79 2 2 64 76 4 7 8 24.9 4.5 5.6 6.2 2 50 24 5 6 6 2 6 07 5 5 8 42 2 6 80 6 4 425 5 5 6 5 7 6 87 2 2 64 9 6 90 5 5 6 5 4.6 8.9 49. 22.4 D D C B C B 99QT, 99ZQT E G F E G F SIZE (DN) DIMENSIONS WEIGT B C D E (LF) F G in. mm in. mm in. mm in. mm in. mm in. mm in. mm in. mm in. mm lbs. kgs. 4 20 0 8 26 5 6 00 5 6 00 2 88 7 6 95 5 8 92 2 6 52 9 6 40 9. 4.2 25 2 4 4 6 22 4 6 22 7 8 98 9 6 2 4 02 2 7 6 62 9 6 40. 6.0 4 2 6 6 407 5 7 8 49 5 7 8 49 5 8 29 6 297 5 8 0 2 5 8 67 2 2 64 24.0 0.9 2 40 6 5 8 42 6 2 64 6 2 64 5 8 29 6 297 5 5 8 4 8 79 2 2 64 0.5.8 2 50 7 5 6 440 6 5 8 68 6 9 6 66 5 8 42 8 40 5 5 6 5 7 6 87 2 2 64 40.6 8.4 Note: The installation of a drain line is recommended. When installing a drain line, an air gap is necessary. See page 57. IMPORTNT: Inquire with governing authorities for local installation requirements 7

Series 957RPD, 957NRPD, 957ZRPD Reduced Pressure Detector ssemblies Sizes: 2 2" 0" (65 250mm) 4 Reduced Pressure Detector ssemblies 957NRPD OSY Series 957RPD, 957NRPD, 957ZRPD Reduced Pressure Detector ssemblies provide protection to the potable water system from contamination in accordance with national plumbing codes. The 957RPD, 957NRPD, 957ZRPD are normally used in health hazard applications to protect against backsiphonage and backpressure. Series 957RPD, 957NRPD, 957ZRPD are used to monitor unauthorized use of water from fire protection systems. Features Extremely compact design 70% lighter than traditional designs Groove fittings allow integral pipeline adjustment Patented torsion spring checks provide lowest pressure loss Unmatched ease of serviceability vailable with grooved butterfly valve shutoffs Replaceable check disc rubber Bottom mounted cast stainless steel relief valve Materials ousing & Sleeve 04 (Schedule 40) Stainless Steel Elastomers EPDM, Silicone and Buna-N Torsion Spring Checks Noryl, Stainless Steel Check Discs Reversible Silicone or EPDM Test Cocks Bronze Body Nickel Plated Pins & Fasteners 00 Series Stainless Steel Springs Stainless Steel Pressure Temperature Temperature Range: F 0 F (0.5 C 4 C) Maximum Working Pressure: 75psi (2. bar) # Testcock Torsion Spring Check Modules Quick ccess Sleeve RV Piston ssembly Corrosion Resistant 00 Series Stainless Steel Body and Sleeve Replaceable Seat Discs RV S/S 8 For additional information, request literature ES-957RPD/957NRPD/957ZRPD. See Flow Charts on p. 77

Dimensions Weights C (open) J I D M G P 4 957RPD SIZE (DN) DIMENSIONS (PPROX.) WEIGT C (OSY) D G I J M P 957RPD 957NRPD in. mm in. mm in. mm in. mm in. mm in. mm in. mm in. mm in. mm in. mm lbs. kgs. lbs. kgs. 2 2 65 787 6 8 46 6 2 65 29 6 78 22 559 5 2 9 8 6 22 2 9 6 548 6 5 42 64 50 68 80 6 805 8 7 8 479 6 6 70 0 4 768 22 4 578 7 8 45 9 6 2 2 8 587 4 2 68 62 7 75 79 4 00 6 856 22 4 578 7 78 88 24 60 8 2 470 9 5 6 252 26 2 67 5 6 86 78 8 20 9 6 50 4 2 05 0 8 765 8 2 26 44 4 7 4 857 2 6 589 6 2 2 4 82 9 48 2 42 5 60 8 200 50 270 7 4 959 9 6 246 54 8 75 40 5 8 02 27 7 6 697 5 6 99 7 8 94 2 6 58 497 225 572 259 0 250 57 2 460 45 4 62 6 285 66 676 50 270 2 2 826 7 5 6 440 46 8 78 24 60 797 62 964 47 957NRPD / 957ZRPD BFG J I M Reduced Pressure Detector ssemblies G P SIZE (DN) DIMENSIONS (PPROX.) WEIGT G I J M P 957RPDBFG in. mm in. mm in. mm in. mm in. mm in. mm in. mm lbs. kgs. 2 2 65 2 2 826 2 2 597 5 2 94 9 2 24 2 6 555 5 6 402 8 7 80 4 864 24 2 622 6 5 6 44 0 6 256 2 8 587 6 8 40 84 8 4 00 5 5 8 905 26 660 7 6 47 0 5 6 279 24 5 6 64 6 5 8 422 0 46 6 50 46 2 8 5 2 6 908 20 2 52 2 4 28 4 78 9 48 74 79 Models Suffix: OSY UL/FM outside stem and yoke resilient seated gate valves OSY FxG - flanged inlet gate connection and grooved outlet gate connection OSY GxF - grooved inlet gate connection and flanged outlet gate connection OSY GxG - grooved inlet gate connection and grooved outlet gate connection BFG UL/FM grooved gear operated butterfly valves with tamper switch for 2 2" 6" (65 50mm) N and Z patterns only vailable with grooved NRS gate valves - consult factory Post indicator plate and operating nut available - consult factory Consult factory for dimensions pprovals 047 (BFG & OSY only) B64.4 Note: The installation of a drain line is recommended. When installing a drain line, an air gap is necessary. See page 57. IMPORTNT: Inquire with governing authorities for local installation requirements 9

Series 994RPD Reduced Pressure Detector ssemblies Sizes 2 2" 6" (65 50mm) 4 Reduced Pressure Detector ssemblies 994RPD OSY Series 994RPD Reduced Pressure Detector ssemblies are designed for use in accordance with water authority containment programs. This series is normally used in health hazard applications to protect against backsiphonage and backpressure. This Series can be used to prevent the reverse flow of fire protection substances, i.e., glycerin wetting agents, foam agents, stagnant water, auxiliary supplies and water of non-potable quality from being pumped or siphoned into the potable water supply. Features Stainless steel construction provides long term corrosion resistance and maximum strength Stainless steel body is half the weight of competitive designs reducing installation and shipping costs Short end to end dimensions makes retrofit easy Bottom mounted relief valve reduces clearance requirements when installed against an outside wall Patented torsion spring check valves provide maximum flow at low pressure drop Thermoplastic and stainless steel check valves for trouble-free operation No special tools required for servicing Compact construction allows for smaller enclosures Stainless steel relief valve features a balanced rolling diaphragm to eliminate sliding seals and lower maintenance costs Detects underground leaks and unauthorized water use. GPM or CFM meter available Materials ll internal metal parts: 00 Series stainless steel Main valve body: 00 Series stainless steel Check assembly: Noryl Pressure Temperature Temperature Range: F 0 F (0.5 C 4 C) continuous Maximum Working Pressure: 75psi (2. bar) Stainless Steel Cover Replaceable Seat Test cocks Torsion Spring Grooved Coupling Stainless Steel Relief Valve Disc Laser Cut/Polished Cam rm 40 For additional information, request literature ES-994RPD. See Flow Charts on p. 78

Dimensions Weights C (open) G D 4 L SIZE (DN) DIMENSIONS (PPROX.) WEIGT C (open) D F G L w/gates w/o Gates in. mm in. mm in. mm in. mm in. mm in. mm in. mm lbs. kg. lbs. kgs. 2 2 65 7 940 6 8 46 0 2 267 7 78 0 254 22 559 48 67 60 27 80 8 965 8 7 8 479 0 2 267 7 2 9 0 254 22 559 226 0 62 28 4 00 40 06 22 4 578 0 2 267 9 229 0 254 22 559 25 07 65 0 6 50 48 2 22 0 8 765 2 292 279 5 8 27 2 699 80 72 0 50 F Reduced Pressure Detector ssemblies Models Suffix LF - without shutoff valves OSY - UL/FM outside stem & yoke resilient seated gate valves CFM - cubic feet per minute meter GPM - gallons per minute meter OSY FxG - flanged inlet gate connection and grooved outlet gate connection OSY GxF - grooved inlet gate connection and flanged outlet gate connection OSY GxG - grooved inlet gate connection and grooved outlet gate connection vailable with grooved NRS gate valves - consult factory Post indicator plate and operating nut available - consult factory Consult factory for dimensions pprovals WW Flange dimension in accordance with WW Class D Note: The installation of a drain line is recommended. When installing a drain line, an air gap is necessary. See page 57. IMPORTNT: Inquire with governing authorities for local installation requirements 4

Series 909RPD Reduced Pressure Detector ssemblies Sizes: 2 2" 0" (65 250mm) st Check Module ssembly 2nd Check Module ssembly 4 Reduced Pressure Detector ssemblies Series 909RPD Reduced Pressure Detector ssemblies are designed exclusively for use in accordance with water utility authority containment requirements on health hazard applications. It is mandatory to prevent the reverse flow of fire protection system substances, i.e., glycerin wetting agents, stagnant water and water of non-potable quality from being pumped or siphoned into the potable water line. Benefits: Detects leaks... with emphasis on the cost of unaccountable water; incorporates a meter which allow the water utility to: Detect leaks that historically create great annual cost due to waste. It provides a detection point for unauthorized use. It can help locate illegal taps. Modular check design concept facilitates maintenance and assembly access. ll sizes are standardly equipped with WW epoxy coated, UL/FM listed OSY resilient seated gate valves, CFM (cubic feet per minute) or GPM (gallon per minute) meter and ball type test cocks. pressure differential relief valve is located in a zone between the check valves. Features Body construction fused epoxy coated cast iron Replaceable bronze seats Maximum flow at low pressure drop Compact for economy combined with performance Design simplicity for easy maintenance Furnished with 5 8" x 4" (6 x 9mm) recordall meter ir-in/water-out relief valve design provides maximum capacity during emergency conditions No special tools required for servicing 909RPD OSY Materials Body: Epoxy coated cast iron Seat and Disc older: Bronze Trim: Stainless steel Check Valve Disc: Durable, tight seating rubber Pressure Temperature Temperature Range: F 40 F (0.5 C 60 C) Maximum Working Pressures: 75psi (2. bar) Pipe Line Center Relief Valve Body Flange Relief Valve Relief Valve Seat Relief Valve Piston Relief Valve Piston ssy. Wiper Seal Bottom Plug Spring ssy. ow it Operates The unique relief valve construction incorporates two channels: one for air, one for water. When the relief vale opens, as in the accompanying air-in/water-out diagram, the right-hand channel admits air to the top of the reduced pressure zone, relieving the zone vacuum. The channel on the left then drains the zone to atmosphere. Therefore, if both check valves foul, and simultaneous negative supply and positive back pressure develops, the relief valve uses the air-in/water-out principle to stop potential backflow. Water Out ir In 42 For additional information, request literature ES-909RPD. See Flow Charts on p. 75

Dimensions Weights 4 G D F E L SIZE (DN) DIMENSIONS (PPROX.) WEIGT C (OSY) D D E, E F, F G L R T T in. mm in. mm in. mm in. mm in. mm in. mm in. mm in. mm in. mm in. mm in. mm in. mm lbs. kgs. 2 2 65 42 8 070 6 8 46 5 4 4 4 4 2 05 8 20 7 78 26 8 664 4 56 9 229 7 5 8 94 20 04 80 42 8 070 8 7 8 479 5 4 4 4 4 2 05 8 20 7 78 26 8 664 4 56 9 229 7 5 8 94 20 04 4 00 55 8 400 22 4 578 6 52 5 7 8 49 7 42 9 229 9 2 24 7 940 5 8 5 8 46 4 299 470 2 6 50 65 2 664 0 8 765 6 52 6 52 20 4 527 0 2 267 4 2 68 44 2 0 6 406 5 8 46 4 299 798 62 8 200 78 2 988 7 4 959 9 4 248 8 5 8 29 26 660 2 292 8 2 470 55 4 40 7 42 8 2 470 6 8 46 456 660 0 250 9 5 8 278 45 4 62 9 4 248 8 5 8 29 2 8 0 2 2 546 67 2 75 8 457 8 2 470 6 8 46 220 02 E F C (Open) R T T D Reduced Pressure Detector ssemblies Models Suffix OSY - UL/FM outside stem & yoke resilient seated gate valves LF - without shutoff valves (4" 0") (00 250mm) CFM - cubic feet per minute meter GPM - gallons per minute meter pprovals 047 pproved by the foundation for Cross- Connection Control and ydraulic Research at the University of Southern California Note: The installation of a drain line is recommended. When installing a drain line, an air gap is necessary. See page 57. Note: Piping for " 909 will start from # gate valve and connect at #2 check valve. IMPORTNT: Inquire with governing authorities for local installation requirements 4

Series 9 Dual Check Vacuum Breakers Sizes: 4" 8" (8 0mm) N9/N9C B B 5 Dual Check Valves N9 CD Series 9 Dual Check Vacuum Breakers are used to prevent the flow of contaminated water into the potable water supply. Models N9C - Dual check backflow preventer with atmospheric vent. For continuous pressure applications. Sizes: 4" (8mm) and 8" (0mm) NPT female inlet and outlet connections. Maximum pressure 25psi (8.6 bar) N9 - the same as N9C except in brass finish NLF9 - as a 8" (0mm) NPT male inlet connection. Maximum pressure 50psi (0. bar). For non-continuous pressure applications N9-CD - In-line field testable, dual check backflow preventer with atmospheric vent. Non-removable design. Size 4" (20mm) T male outlet connection. Maximum temperature 80 F (82 C). lso available with chrome plating, Model N9-CD-C 9BD - Special backflow preventer for vending machine water supply lines Complies with FD food additive regulations. Standard size: 8" (0mm) flair copper tube (FCT) inlet and outlet Maximum pressure 50psi (0. bar) Maximum temperature 40 F (60 C) 92P - igh pressure hose drop backflow preventer for food processing plat washdown lines. Sizes: 4" (20mm) and " (25mm). Female inlet x male outlet connection. Maximum pressure 400psi (27.5 bar). Maximum temperature 60 F (7 C) Patent # 6,97,878 pprovals NLF9 N9-CD 9BD B B B B B Dimensions Weights N9 CS B64.8 N9-CD SSE 052 9BD CS B64.8 NLF9 SSE 05, CS B64.8 MODEL SIZE DIMENSIONS WEIGT B B in. mm in. mm in. mm in. mm lbs. kgs. N9C 4 6 2 8 60 4 2 25.8.7 N9C 8 0 2 8 60 4 2 25.8.7 N9 4 6 2 8 60 4 2 25.8.7 N9 8 0 2 8 60 4 2 25.8.7 NLF9 8 0 2 8 60 4 2 25.8.7 NLF9 4 20 2 8 70 4 2 25.8.7 N9 CD 4 20 2 8 60 2 8 25.8.7 9BD 8 0 2 4 70 8 5.8.7 9BD 4 6 2 4 70 8 5.8.7 9BD 8 0 2 4 70 8 5.8.7 92P 92P SIZE DIMENSIONS (PPROX.) WEIGT C D D in. mm in. mm in. mm in. mm in. mm in. mm lbs. kgs. 4 20 9 6 2 8 5 6 2 25 7 6 7 2 8 25 0 254 9 5 6 27 25 7 6 7 2 8 4 2 D B C D IMPORTNT: Inquire with governing authorities for local installation requirements 44 For additional information, request literature ES-9 or ES-N9-CD or ES/IS-92P. See Flow Charts on p. 66

Series 9D Backflow Preventer with Intermediate tmospheric Vent Sizes: 2", 4" (5, 20mm) 9D Series 9D Backflow Preventer with Intermediate tmospheric Vent is specially made for smaller supply lines and ideally suited for laboratory equipment, processing tanks, sterilizers, dairy equipment and similar applications. It is particularly recommended for boiler feed lines to prevent backflow when supply pressure falls below system pressure. 9D is suitable for use on hot or cold water and can be used under continuous pressure. It features a primary check valve utilizing a rubber disc seating against a mating rubber part to ensure tight closing. secondary check valve utilizes a rubber disc-to-metal seating. In the event of fouling of the downstream check valve, leakage would be vented to atmosphere through the vent port thereby safeguarding the potable water system. 5 Dual Check Valves Features True line sizes construction allows the check modules to open further allowing dirt and debris to pass more freely reducing check fouling Stainless steel internal part Maximum flow at low pressure drop Furnished with union connections to facilitate removal and replacement for maintenance Compact for economy combined with performance Design simplicity for easy maintenance Can be installed vertically or horizontally Dimensions Weight Materials Body: Brass Internal Parts: Stainless steel Check Valve ssemblies: Durable, tight sealing rubber Pressure Temperature Temperature Range: F 250 F (0.5 C 2 C) Minimum Working Pressure: 25psi (72 kpa) Maximum Working Pressure: 75psi (2. bar) Models Suffix S - 2" (5mm) union end solder connections SC - satin chrome finish LU - less union pprovals 02 CS N.Y.C. BS 04-75-SM Tested and approved Conformance with Standard 02 of the merican Society of Sanitary Engineers and by all principal cities, states and areas having these requirements. MODEL SIZE (DN) DIMENSIONS (PPROX.) WEIGT B C D in. mm in. mm in. mm in. mm in. mm lbs. kgs. 9D-M 2 5 4 5 6 25 2 9 6 65 2 9 6 65 5 6 49.5.68 9DS-M 2 5 4 8 2 9 6 65 2 9 6 65 7 8 48.5.68 9D-M2 4 20 4 5 6 25 2 2 64 2 9 6 65 5 6 49.75.79 9DS-M2 4 20 4 6 22 2 2 64 2 4 70 2 6 52.75.79 B C D IMPORTNT: Inquire with governing authorities for local installation requirements See Flow Charts on p. 67 For additional information, request literature ES-9. 45

Series SD-2, SD- Dual Check Valves Sizes: 4" 8" (8 0mm) SD-2 SD- 5 Dual Check Valves Series SD-2 and SD- Dual Check Valves are designed for the protection of the water supply from carbon dioxide gas and carbonated water. These substances can flow from post-mix beverage systems and are very acidic. If acidic water comes in contact with copper pipe, it will cause the leaching of copper salts into the water supply and if ingested can cause nausea, abdominal pain, and in some cases vomiting. SD-2 and SD- prevent the reverse flow of potentially contaminated water into the potable water supply due to back pressure backflow and is used for continuous or intermittent pressure conditions. SD-2 and SD- are recommended for use on Post-Mix Carbonated Beverage Equipment and dispensing equipment for tea and coffee. Features Both Models Certified to NSI/NSF Standard 8, Manual Food and Beverage Dispensing Equipment Streamlined body design minimizes pressure loss and cavitation wide variety of custom end connections are available Endurance tested for more than 500,000 pumping cycles Shock tested for more than 00,000 pumping cycles Dimensions Weights SD- Only tmospheric port provides visual indication of failure of the second check Wye pattern strainer model for water supply installations Materials Body: 6 stainless steel, corrosion resistant Internal rubber components, comply with FD food additive regulations M Pressure Temperature SD-2 Temperature Range: F 0 F (0.5 C 4 C) Maximum Working Pressure: 200psi (.8 bar) SD- Temperature Range: F 0 F (0.5 C 54 C) Maximum Working Pressure: 50psi (0. bar) Models SD-2 4" (8mm) SD2-MN - Male NPT 8" (0mm) SD2-MN - Male NPT 4" (8mm) SD2-FN - Female NPT 8" (0mm) SD2-FN - Female NPT 4" (8mm) SD2-MF - SE Male Flare 8" (0mm) SD2-FF - SE Male Flare 4" (8mm) SD2-FF - SE Female Flare 8" (0mm) SD2-FF - SE Female Flare SD- 4" (8mm) SD-MN - Male NPT 8" (0mm) SD-MN - Male NPT 4 (8mm) SD-FN - Female NPT 8" (0mm) SD-FN - Female NPT 4" (8mm) SD-MF - SE Male Flare 8" (0mm) SD-MF - SE Male Flare 8" (0mm) SD-MF-LS - SE Male Flare, less strainer SD-2 MODEL SIZE (DN) DIMENSIONS (PPROX.) B in. mm in. mm in. mm SD2-MN 4 8 76 6 27 8 0 76 6 27 SD2-MF 4 8 2 6 7 6 27 8 0 76 6 27 SD2-FN 4 8 76 6 27 8 0 76 6 27 SD2-FF 4 8 2 6 7 6 27 8 0 76 6 27 B cross Corners N SD- B cross Corners pprovals SD-2 - SSE 02; SD- SSE 022 NSF NSI Standard 8 MODEL SIZE (DN) DIMENSIONS (PPROX.) B M N in. mm in. mm in. mm in. mm in. mm SD-MN 4 8 4 2 4 6 27 7 8 48 6 4 8 0 4 2 4 6 27 7 8 48 6 4 SD-MF 4 8 4 8 6 27 7 8 48 6 4 8 0 4 2 4 6 27 7 8 48 6 4 SD-FN 4 8 4 2 4 6 27 7 8 48 6 4 8 0 4 2 4 6 27 7 8 48 6 4 46 For additional information, request literature ES-SD2 or ES-SD. See Flow Charts on p. 79

Series 7 Dual Check Valves 7 Sizes: 2" 4" (2 2mm) 7C Sizes: 8" (0mm) Series 7 Dual Check Valves are designed for non-health hazard residential water system containment and continuous pressure applications, such as the drinking water supply service entrance or individual outlets. Series 7 uses two compact replaceable check modules and is installed immediately downstream of the residential water meter. 7 Features Can be installed vertically or horizontally vailable with an extensive combination of inlet/outlet sizes, types or thread and end connection including retrofit compression fittings and hose connections Can be installed in many piping configurations and with a wide range of meter horns, copper setters and meter boxes 7C, chrome-nickel plated brass dual check for in-line continuous pressure application Materials Bronze body: 7 bronze 7C chrome-nickel plated Check Modules: Durable plastic Discs: Silicone Seals: Buna-N Springs: Stainless steel Pressure Temperature Temperature Range: F 80 F (0.5 C- 82 C) continuous, 80 F (82 C) intermittent Maximum Working Pressure: 50psi (0. bar) pprovals 024 B64.6 Dimensions Weights B MODEL SIZE (DN) DIMENSIONS WEIGT B in. mm in. mm in. mm lbs. kgs. 7C 8 0 2 7 8 7 4 2.6 0.7 7U2-2 2 5 4 8 2 8 60.75 0.8 7U2-2 4 20 4 8 2 8 60.75 0.8 7U2-2 25 4 8 2 8 60.75 0.8 5 Dual Check Valves Flow Charts on p. 66 For additional information, request literature PG-7. Series Cu7 Copper-Body Dual Check Valves Sizes: 2" " ( 25mm) Series Cu7 Copper-Body Dual Check Valves feature a poppet-type construction that minimizes pressure drop and provides smooth flow characteristics. Cu7 can be installed horizontally or vertically and its copper body is lead free and is constructed from time proven material. ll models are standardly furnished with double unions for ease of installation and repair. Features Can be installed vertically or horizontally Lead free copper body Module check valves for easy maintenance Chloramine resistant materials of construction Double unions for installation ease Replaceable seats Center stem guides for reliable seating Pressure-Temperature Temperature Range: F 80 F (0.5 C-82 C) Maximum Working Pressure: 50psi (0. bar) pprovals 024 Standard 6 IMPORTNT: Inquire with governing authorities for local installation requirements Cu7 Dimensions Weights CU7 B SIZE (DN) DIMENSIONS WEIGT B in. mm in. mm in. mm lbs. kgs. 2 5 4 7 6 2 8 60.7 0.8 4 20 4 7 6 2 8 60.7 0.8 25 4 6 9 2 8 60 2 0.9 See Flow Charts on p. 66 For additional information, request literature PG-7. 47

Series L7U2-2 In-Line Testable/Serviceable Dual Check Valves Series L7U2-2 In-Line Testable/Serviceable Dual Checks are designed to backup the local or state plumbing code requirements for each premise served and to provide residential backflow protection from conditions such as mainline flushing, fire fighting and water main breaks. These conditions can siphon domestic water system, drawing potentially polluted water in the system back into the public water supply. 5 Dual Check Valves Features Plugged test ports for in-line testing Sizes 4" and " (20 and 25mm) L7U2-TC with test cocks L7U2-2TC-QT with test cocks and quarter-turn shutoffs Model 7B Dual Check Valves Sizes: 4" (9mm) Features Compact design in machine brass construction Maximum Pressure - 50psi (0. bar) Maximum Temperature - 40 F (60 C), 4" (20mm) inlet and outlet, NPT threaded connections No 7BU-2 has female union inlet x female union outlet pprovals 024 No 7BU2/U2 female union inlet x female union outlet Length 4" (00mm); eight 2" (8mm); Weight lb (.5kg) pprovals 024 L7U2-2 Flow Charts on p.66 7B Flow Charts on p.66 Series 07S Residential Fire Sprinkler System Dual Check Valves Sizes:, 4" (25, 2mm) Features Cast bronze body Maximum pressure: 75psi (2. bar) Maximum temperature: 40 F (60 C) Length 6 4" (7mm); eight 2 6" (7mm); Weight lbs (.4 kg) pprovals 024 07S Flow Charts on p.66 IMPORTNT: Inquire with governing authorities for local installation requirements 48 For additional information, request literature PG-7.

Series 8 ose Connection Vacuum Breakers Sizes: 8" 4" (0 20mm) 8 8B 8FR Series 8 is a line of unique vacuum breakers specially made to permit the attachment of portable hoses to hose thread faucets. Designed to prevent the flow of contaminated water back into the potable water supply, these devices require no plumbing changes, and screw directly onto a sill cock. Series 8 can be used in a wide variety of installations, such as service sinks, swimming pools, photo developing tanks, laundry tubs, wash racks, dairy barns, marinas and general outside gardening uses. Materials Body: brass (all models expect 8P) Stainless steel working parts for longevity Durable rubber diaphragm and disc for consistent positive seating Models 8 - brass body, removable, non-draining 8 - patented non-removable feature, drainable, interlocking spring prevents removal once installed 8B - brass body, with breakaway set screw to prevent removal, drainable 8C, 8BC and 8C - same as above in chrome finish Dimensions Weights NF8C - specifically designed for wall and yard hydrants, permits manual draining for freezing conditions. Chrome finish 8P - thermoplastic body with patented non-removable feature and equipped to allow sill cock to be drained S8C - designed for tub and shower hand spray sets. Chrome finish S8 - same as above with plain brass finish 8FR - with freeze relief features. Protects the valve from freeze damage with or without the hose attached (Patent Pending) Note: Models 8, 8 and 8B are not suitable for frost-free hydrants. See Model NF8. pprovals 0 B64.2 Series 8, 8, 8B, 8P, 8FR and NF8 are listed by IPMO 6 Vacuum Breakers MODEL SIZE (DN) DIMENSIONS (PPROX.) WEIGT B in. mm in. mm in. mm oz. gm. 8 4T 20 8 5 2 8 4.4 8 4T 20 2 8 2 8 4.4 8C 4T 20 2 8 2 8 4.4 8B 4T 20 2 8 8 5 4.4 8BC 4T 20 8 5 2 8 4.4 8C 4T 20 8 5 2 8 4.4 NF8 4T 20 2 8 2 50 5. 5.2 NF8C 4T 20 2 8 2 50 5. 5.2 8P 4T 20 4 44 8 5 2 56.7 S8 2F 5 4 2 2 8.5 42.5 S8C 2F 5 4 2 2 8 4.4 S8C 8F 0 4 2 2 8 4.4 8FR 4T 20 4 44 4 44 7.0 200 IMPORTNT: Inquire with governing authorities for local installation requirements T = ose threaded connections, female inlet x male outlet connection Female NPT threaded inlet x male NPT outlet connection B See Flow Charts on p. 66 For additional information, request literature ES-8. 49

6 Vacuum Breakers Series 800M4QT, 800M4FR Pressure Vacuum Breakers Sizes: 2" 2" (5 50mm) Series 800M4 QT and 800M4FR Pressure Vacuum Breakers are designed to prevent backsiphonage of contaminated water into the potable water supply and are for health hazard cross-connections subject to continuous pressure. These valves must be installed 2" (05mm) above the highest downstream point of water. Features Sizes 2" " (5 25mm) come standard with tee handle quarter-turn shutoffs Sizes 4" 2" (2 50mm) come standard with lever handles Dimensions Weights MODEL SIZE (DN) DIMENSIONS (PPROX.) WEIGT 800M4QT B C D in. mm in. mm in. mm in. mm in. mm lbs. kgs. 800M4QT 2 5 5 27 6 4 59 2 9 6 65 6 94.5.6 800M4QT 4 20 5 8 7 6 2 65 2 9 6 65 5 6 00.5.6 800M4QT 25 5 2 9 7 2 9 2 4 70 4 4 2 6 2.7 800M4QT 4 2 8 5 8 29 9 229 4 8 5 4 46 4.9 800M4QT 2 40 9 229 9 2 24 4 8 6 4 59.5 6. 800M4QT 2 50 9 2 24 9 5 8 245 4 8 6 8 62 8.5 8.4 800MQT 2 5 4 7 8 24 5 8 7 2 2 64 2 7 8 7.4 800MQT 4 20 4 7 8 24 5 8 7 2 2 64 2 7 8 7.4 Flow Charts on p. 74 For additional information, request literature ES-800M4QT or ES-800M4FR. Series 008PCQT Spill Resistant, nti-siphon Vacuum Breakers Sizes: 8" " (0 25mm) Temperature Pressure Temperature Range: F 40 F (0.5 C 60 C) Maximum Working Pressure: 50psi (0. bar) pprovals 020 Models 800M4FR - with relief valve for freeze protection. Patent #5,55,47. 800M QT - compact model with selfcontained ball valve shutoffs. vailable in sizes 2" and 4" (5 and 20mm). C D B Series 008PCQT Spill Resistant, nti-siphon Vacuum Breakers are designed for indoor point of use health hazard applications to prevent backsiphonage of contaminated water back into the potable water supply. Separation of the water supply from the air inlet is accomplished by means of a diaphragm seal. This feature protects against any spillage during start-up or operation. Features Standardly supplied with internal polymer coating Standardly supplied with Tee handles vailable less Tee handles with stem wrench flats. For use where space is limited vailable in left-handed or right-handed outlet Patented design Spill-resistant design for indoors use ffordable design Modular cartridge for ease of service Vent uses an O-ring for reliable operation Dimensions Weights Materials Body: Bronze Springs: Stainless steel Bonnet and Disc older: PPO Vent Disc: EPDM Check Disc: Silicone rubber Pressure Temperature Temperature Range: F 80 F (0.5 C 8 C) Maximum Working Pressure: 50psi (0. bar) MODEL SIZE (DN) DIMENSIONS (PPROX.) WEIGT B C D in. mm in. mm in. mm in. mm in. mm lbs. kgs. 008PCQT 8 0 4 8 07 5 2 40 9 6 40 5 6 00.6.7 008PCQT 2 5 4 8 5 2 40 9 6 40 4 6 06.7.5 008PCQT 4 20 4 5 6 25 7 78 2 8 60 4 5 8 7.8.7 008PCQT 25 5 27 7 2 9 2 8 60 5 8 0 4.8 2.2 Models 008PCQT SC - satin chrome finish with wrench flats in place of Tee handles (contact factory) S - bronze strainer L - left sided test cock pprovals IMPORTNT: Inquire with governing authorities for local installation requirements 50 For additional information, request literature ES-008PCQT. See Flow Charts on p. 65 056 IMPO Classified C D B

Series 88, 288, 289, N88 nti-siphon Vacuum Breakers Sizes: 4" " (8 80mm) Series 88, 288, 289, N88 nti-siphon Vacuum Breakers are designed to protect against backsiphonage of contaminated water into the potable water supply. These vacuum breakers are for health hazard cross-connections not subject to continuous pressure and must be installed 6" (50mm) above the highest downstream point of water. Models 88 - Sizes 4" 2" (20 50mm) irrigation vacuum breaker. Plain brass finish 288 - Sizes 4" " (8 80mm). Plain brass finish 288C - Sizes 4" " (8 25mm). Polished chrome finish Dimensions - Weights 289 - Sizes 8" " (0 25mm). Spill resistant atmospheric vacuum breakers. NPT male connections N88 - Sizes 4" and 8" (8 and 0mm) with NPT female bottom inlet and outlet connections. Bronze body pprovals Model 88 00 B64. Models 288/N88 289 N88 SIZE (DN) DIMENSIONS (PPROX.) WEIGT CC in. mm in. mm in. mm lb. kgs. 4 8 4 44 4 20.5.2 8 0 4 44 7 8 60.75.4 4 8 4 44 4 20.5.2 8 0 4 44 7 8 60.75.4 289 SIZE (DN) DIMENSIONS (PPROX.) WEIGT B C D in. mm in. mm in. mm in. mm in. mm lb. kgs. 8 0 2 8 2 8 60 4 95 2 5.9.4 2 5 2 8 2 8 60 4 95 2 5.4 4 20 2 8 60 2 2 64 5 27 4 95.4 25 2 8 60 2 2 64 5 27 4 95 4.8 00 B64. Model 289 00 N88 D 6 Vacuum Breakers 88 SIZE (DN) DIMENSIONS (PPROX.) WEIGT C D in. mm in. mm in. mm in. mm lbs. kgs. 4 20 2 4 57 7 8 48 2 8..5 25 2 7 8 7 2 8 54 6 4.75.79 4 2 2 7 8 7 2 8 54 6 46 2..96 2 40 5 8 92 2 7 6 62 2 6 56.5.64 2 50 4 8 05 2 7 8 7 2 2 64 5.25 2.8 289 D CC B C 288 SIZE (DN) DIMENSIONS (PPROX.) WEIGT B C D in. mm in. mm in. mm in. mm in. mm oz. gm. 4 8 4 44 2 4 57 4 2 25 6 70 8 0 4 44 2 4 57 4 2 25 6 70 2 5 2 50 2 4 70 2 8 4 2 8 227 4 20 2 4 57 76 2 8 2 8 8 50 25 2 7 8 7 5 8 92 7 8 48 4 44 28 794 4 2 2 7 8 7 4 95 7 8 48 7 8 48 4 964 2 40 5 8 92 4 2 4 57 2 4 57 54 5 2 50 4 00 5 8 0 2 5 8 67 2 2 64 84 28 2 2 65 6 2 65 7 2 9 4 2 4 76 256 7258 80 6 2 65 8 200 4 5 8 7 8 86 274 7768 88/288 C B D See Flow Charts on p. For additional information, request literature PG-VB. 5

7 Miscellaneous Backflow Products Series WB WattsBox Insulated Enclosures WattsRock Enclosure Features Designed to eliminate valve vault entry requirements of OS confined space ruling 29CFR 90.46 Single source Watts Regulator warranty of the enclosure, the backflow preventer, and the heat source llows for the installation of the backflow preventer at the service connection in accordance with WW Standards Specifically designed to meet NFP guidelines. The enclosure provides freeze protection to maintain the water supply to the property s fire protection system (NFP -..8 and.6...2) Strategically placed doors provide access to the backflow prevention assembly for testing and repair without removal of the entire unit n economical alternative to expensive retrofit installation Eliminates potential drainage constraints in existing equipment rooms Saves valuable floor space Standardly furnished with thermostatically controlled heat source for freeze protection down to -0 F (-4 C) Contains no structural wood or particle board for long life Dimensions FIBERGLSS DIMENSIONS 2" CLERNCE MOUNTING FITS WTTS VLVES WTTS MODEL Length x Width x eight PD SIZE Thru 4" (20mm) 007, 009, 909, 79, 99 WB-75 9" x " x 22" 28" x 20" Thru " (25mm) 007, 009, 909, 79, 99 WB- 27" x " x 2" 6" x 22" Thru 2" (40mm) 007, 009, 909, 79, 99 WB-.5 " x 2" x 25" 44" x 2" Thru - 2" (50mm) 007, 009, 909, 79, 99 WB-2 9" x " x 28" 50" x 24" 4" - " (20-25mm) 800, 008, 288, 289 WB-PVB 8" x 9" x 8" 9" x 27" (Increases height by 6") WB-PVB T 8" x 9" x 24" 9" x 27" 4" - 2" (2-50mm) 800, 288 WB-PVB2 26" x 2" x 20" 2" x 5" (Increases height by 8") WB-PVB T2 26" x 2" x 28" 2" x 5" 2 2" - " (65-80mm) all 007, 009, 009, 909 4" (00mm) 774 NRS / OSY / DCD 4" (00mm) 994NRS, " (80mm) 775NRS / OSY / DCD, " (80mm) 995NRS, 4"(00mm) 775NRS, 4" (00mm) 994NRS, 2 2" - " (65-80mm) 757DCD, 2 2" - " (65-80mm) 957QT, 2 2" - " (65-80mm) 957RPD WB-N 70" x 26" x 45" 82" x 8" 4" (00mm) 994OSY / RPD, 4"(00mm) 775OSY / DCD, " (80mm) 995OSY / RPD WB-E 70" x 26" x 55" 82" x 8" 2 2" - " (65-80mm) 957N NRS / OSY / BFG / QT, 4" (00mm) 957N NRS / BFG / QT WB 000 45" x 5" x 5" 57" x 47" 4" (00mm) 957N OSY, 4"(00mm) 757DCD WB 4000 5" x 44" x 44" 65" x 56" LUMINUM 4" (00mm) 709NRS / OSY / DCD, 4" (00mm) 909NRS / OSY / RPD, 6" (50mm) 774NRS / OSY / DCD, 6" (50mm) 994NRS, 6" (50mm) 775NRS, 6" (50mm) 995NRS, 8" (200mm) 775NRS, 4" (00mm) 757NRS / OSY, 6"(50mm) 757NRS / OSY / BFG, 8" (200mm)757NRS / BFG, 4" 757DCD, 6" (50mm) 757DCD, 4" (00mm) 957OSY, 6" (50mm) 957NRS, 8" (200mm) 957NRS WB-N4 90" x 2" x 50.5" 02" x 44" 6" (50mm) 957OSY, 6" (50mm) 957RPD WB-E4 90" x 2" x 57.5" 02" x 44" 6" (50mm) 709NRS / OSY / DCD, 6" (50mm) 909NRS / OSY / RPD, 8" (200mm) 774, 994NRS, 0" (250mm) 774 NRS, 0" (250mm) 957NRS WB-N6 05" x 6" x 5" 7" x 48" 6" (50mm) 994 OSY / RPD, 8"(200mm) 774 OSY / DCD, 0" (250mm)994 NRS, 6" (50mm) 775OSY / DCD, 8" (200mm) 775OSY / DCD, 6" (50mm) 995OSY / RPD, 8" (200mm) 757OSY, 0" (250mm) 757NRS, 8" (200mm) 757DCD, 8" (200mm) 957OSY, 8" (200mm) 957RPD WB-E6 05" x 6" x 64" 7" x 48" 8" (200mm)709, 909 NRS WB-N8 8" x 40" x 58" 0" x 52" 8" (200mm)709OSY / DCD, 8"(200mm) 909, 994OSY / RPD, 0" (250mm)774OSY / DCD, 8" (200mm)757OSY / DCD, 8" (200mm) 957OSY / RPD, 0" (250mm) 757NRS, 0" (250mm) 957NRS WB-E8 8" x 40" x 74" 0" x 52" 0" (250mm) 709, 909NRS WB-N0 42" x 42" x 65" 54" x 54" continued on next page 52 For additional information, request literature ES-WB.

Features (cont.) Easy installation aluminum enclosures features interlocking panel which eliminates the use of screws during assembly Can be temporarily removed for replacement of the backflow preventer without the need for replacement of freeze protection services Flip top fiberglass enclosures standardly furnished with locking pin to lock the lid in the open position SSE 060 certified WattsRock available in slate grey and earthtone brown Dimensions (cont.) LUMINUM (CONT.) DIMENSIONS 2" CLERNCE MOUNTING FITS WTTS VLVES WTTS MODEL Length x Width x eight PD SIZE 0" (250mm) 709OSY / DCD, 0" (250mm) 909, 994OSY / RPD, 0" (250mm) 757OSY / DCD, 0" (250mm) 957OSY / RPD WB-E0 42" x 42" x 85" 54" x 54" 2 2" - " (65-80mm) 757N OSY, 4"(00mm) 757N NRS / BFG, 6" (50mm) 757N NRS, BFG, 6" (50mm) 957N BFG WB 4000N 5" x " x 44" 65" x 45" 4" (00mm) 757N OSY, " 757N DCD, 6" (50mm) 957N NRS, 8" (200mm) 957N NRS, 2 2" - " (65-80mm) 957N RPD, 4" (00mm) 957N RPD WB 4000E 5" x 44" x 44" 65" x 56" 8" (200mm) 757N NRS, 4"(00mm) 957 QT WB 6000N 62" x 9" x 46" 74" x 5" 6" (50mm) 757N OSY, 6" (50mm) 757N DCD, 6" (50mm) 957N OSY, 8" (200mm) 957N NRS, 6"(50mm) 957N RPD WB 6000E 62" x 5" x 46" 74" x 65" STUCCO LUMINUM 2 2" - " (65-80mm) 757N NRS / BFG / QT WB 2000 9" x 24" x 2" 42" x 4" 2 2" - " (65-80mm) 757NRS, QT, BFG, 4" (00mm) 757BFG WB 2.5 60" x 22" x 0" 6" x 2" 2 2" - " (65-80mm) 757OSY, 2 2" - " (65-80mm) 957NRS / OSY, 4" (00mm) 957NRS WB 2.75 60" x 22" x 42" 6" x 44" 0" (250mm) 757OSY, 0" (250mm) 757DCD, 0" (250mm) 957OSY, 0" (250mm) 957RPD WB 6 ET 05" x 6" x 80" 08" x 82" 0" (250mm) 757N NRS WB 8000NT 7" x 45" x 60" 75" x 62" 8" (200mm) 757N OSY, 8"(200mm) 757N DCD, 0" (250mm) 757N OSY, 0" (250mm) 757N DCD, 8" (200mm) 957N OSY, 0"(250mm) 957N NRS, 0" (250mm) 957N OSY, 8" (200mm)957N RPD,0" (250mm) 957N DCD WB 8000ET 7" x 67" x 60" 76" x 62" WTTSROCK - SLTE GREY OR ERTTONE BROWN 4" - " (20-25mm) 007, 009, 79, 775, 909, 99, 995 WPLRN- (shell) 28" x 2" x 2" 40" x 24" 4" - " (20-25mm) 007, 009, 79, 775, 909, 99, 995 WPLR- (less heat) 26" x 0" x 22" 40" x 24" 4" - " (20-25mm) 007, 009, 79, 775, 909, 99, 995 WPR- (w/heat) 26" x 0" x 22" 40" x 24" 4" - 2" (2-50mm) 007, 009, 79, 775, 909, 99, 995 WPLRN-2 (shell) 45" x 4" x 28" 56" x 22" 4" - 2" (2-50mm) 007, 009, 79, 775, 909, 99, 995 WPLR-2 (less heat) 4" x 2" x 27" 56" x 22" 4" - 2" (2-50mm) 007, 009, 79, 775, 909, 99, 995 WPR-2 (w/heat) 4" x 2" x 27" 56" x 22" 7 Miscellaneous Backflow Products STRINER MODELS 4" - 2" (8-50mm) WB-2S 47" x " x 28" 58" x 24" 2 2" - " (65-80mm) NRS WB-NS 8" x 26" x 45" 95" x 8" 2 2" - " (65-80mm) OSY WB-ES 8" x 26" x 55 95" x 8" 4" (00mm) NRS WB-N4S 02" x 2" x 50.5" 4" x 44" 4" (00mm) OSY WB-E4S 02" x 2" x 57.5" 4" x 44" 6" (50mm) NRS WB-N6S 25" x 6" x 5" 7" x 48" 6" (50mm) OSY WB-E6S 25" x 6" x 64" 7" x 48" 8" (200mm) NRS WB-N8S 42" x 40" x 58" 54" x 52" 8" (200mm) OSY WB-E8S 42" x 40" x 74" 54" x 52" 0" (250mm) NRS WB-N0S 72" x 42" x 65" 84" x 54" 0" (250mm) OSY WB-E0S 72" x 42" x 85" 84" x 54" 5

Series TWS Through the Wall shutoffs Sizes: 4", " (20, 25mm) Series TWS Through the Wall shutoffs are for use on irrigation sprinkler systems and feature a provision for a pressure vacuum breaker (PVB), atmospheric vacuum breaker (VB), double check (DC) or reduced pressure zone (RPZ) backflow preventer. Series TWS provides access to the home s water supply from the outside and its shutoff is key operated. Pressure Temperature Temperature Range: F 40 F (0.5 C - 60 C) continuous, 80 F (82 C) intermittent Maximum Working Pressure: 75psi (2. bar) Models Sizes: 4", " (20, 25mm), NPT male outlet connection 8", 0", 2" (200, 250, 00mm) shaft lengths Dimensions MODEL SIZE (DN) in. mm. TWS-8 4 20 TWS-0 4 20 TWS-2 4 20 TWS-8 25 TWS-0 25 TWS-2 25 For additional information, request literature ES-TWS. 7 Miscellaneous Backflow Products Series Governor 80-M Ball Cock and Thermal Expansion Relief Valve Sizes: 0", 2", 2 2" (250, 292, 8mm) Governor 80-M is a triple purpose product: toilet tank ball cock fill valve, antisiphon backflow preventer and thermal expansion pressure relief valve. Pressure Temperature Temperature Range: F 0 F (0.5 C 4. C) Relief Valve Set t: 80psi (552 kpa) pprovals IPMO Listed CS Certified for anti-siphon ball cocks FD approved under CFR-2-77-2600 NSI/SSE 002 Dimensions MODEL in. SIZE (DN) mm Gov 80-M 0 0 250 Gov 80-M 2 2 292 Gov 80-M 2 2 2 2 8 For additional information, request literature S-Gov80. Series SS07F Stainless Steel Single Detector Check Valves Sizes: 4" 0" (00 250mm) Series SS07F Single Detector Check Valve (DCV) detects any leakage or unauthorized use of water from fire sprinkler systems. During times of minimal water flow, the valve clapper remains closed so that the water flows through a bypass meter (optional). When fire flow is required, the increased demand will open the clapper to allow full flow. Pressure Temperature Temperature Range: F-0 F (0.5 C-4 C) Rated working pressure: 75psi (2. bar) Flange bolt pattern and hole diameter in accordance with NSI B6.5 Class 25/WW C207 Class D Body nameplate provides nominal size, direction of flow, psi rating, year of manufacture, and approval marks pprovals Listed 8" and 0" (200-250mm) only 54 For additional information, request literature ES-SS07F. See Flow Charts on p. 79

Test Kits Model TK-7 Water column sight tube for testing dual check and double check valves. Tests individual check modules of the Watts Model 7, 709 and 007. For additional information, request literature IS-TK7 or PG-TK. MODEL WEIGT lbs. kgs. TK-7 5 2. Model TK-9 ± 2% accuracy full scale Test kit easily connects to any testable backflow preventer assembly. Designed for testing all testable backflow preventers. MODEL WEIGT lbs. kgs. TK-9 8.6 Maximum pressure 75psi (2. bar). Maximum temperature 20 F (98.9 C). Model TK-99D Model TK-99E For additional information, request literature IS-TK9 or PG-TK. Features 0.25% full scale accuracy. Compact, hand held, digital backflow preventer test kit. LCD display with oversized differential characters and separate supply pressure readout gauge, high impact casing. Tests RPZ s, Double checks or PVB s. For additional information, request literature IS-TK-99D or PG-TK. ± % accuracy full scale. Compact test kit with color coded valves, hoses and top mounted bleed valves. Designed for testing all testable backflow preventers. MODEL WEIGT lbs. kgs. TK-99D.4 MODEL WEIGT lbs. kgs. TK-99E 8.6 7 Miscellaneous Backflow Products Model TK-DL For additional information, request literature IS-TK-99E or PG-TK. With Digital Print-Out and Computer Download Capability ± 0.2% accuracy full scale. n advanced piece of test equipment designed to make pressure and differential gauges obsolete in the testing of backflow preventers. ccuracy, portability, versatility and documentation. Contains hoses, adapters, digital printout unit and a rugged case. IMPORTNT: Inquire with governing authorities for local installation requirements MODEL WEIGT lbs. kgs. TK-DL 5 6.8 For additional information, request literature IS-TK-DL or PG-TK. 55

Test Cocks For use with backflow preventers, isolation valve for gauges, isolation valves for small equipment lines. TC TC full port ball valve design Screw driver slot to open and close vailable 8" M x 4" F or 4" M x 4" F (mm M x 8mm F or 8mm M x 8mm F) SE-TC Full port ball valve design Screwdriver slot operation 8" (mm) M x SE SE-TC dapter 7 Miscellaneous Backflow Products 4" (8mm) female SE x 7 6" (4mm) FPT dapts to SE-TC for use with pressure gauge and/or site tube SE-TC dapter 8" (mm) SE-TC Brass Cap SilverEagle TC 2" (5mm) TC for 2 2" 4" (65-00mm) series 757 and 957 4" (20mm) TC for 6" 0" (50-250mm) series 757 and 957 Full port ball valve design No. TC with O-Ring for 2 2" 4" (65-00mm) series 757 and 957 for 6" 0" (50-250mm) series 757 and 957 Caps & Tethers Plastic Cap and tether (four required per backflow preventer) Fits 4" (8mm) Female test cocks Plastic dust cap and rubber tether RK-TC P SE Brass Cap, O-ring and Tether (four required per backflow preventer) Fits 8" (8mm) M x SE test cocks Brass dust cap with O-ring seal and rubber tether RK-SE-TC-B 56 For additional information, request literature ES-G/EL/TC.

ir Gaps and Elbows for Reduced Pressure Zone ssemblies Sizes: 4" 0" (8 250mm) for RPZ and RPD 994 Splash Guard 909 ir Gaps 909 n air gap provides the unobstructed, physical separation between the discharge end of a potable water supply line and an open receiving vessel. The installation of an air gap and drain line are recommended. Elbow 957 G Model 994 and 994RPD Sizes: 2 2" 0" (65-250mm) 7 orizontal ir Gaps. Remove two of the relief valve capscrews 80 apart. 2. Remove the relief valve hose from fitting below inlet ball valve.. From the top of the air gap, thread the relief valve hose down and out the slot. 4. Use 4" - 20 UNC x " long stainless steel screws. 5. Reconnect relief valve hose to the fitting below the inlet ball valve. ir Gaps Vertical ir Gaps. Detach the sensing line from the inlet ball valve and the elbow on the relief valve. 2. Remove the elbows from the relief valve base.. ang the ir Gap Drain on the body of the relief valve 4. Reinstall the elbow into the base of the relief valve to hold the ir Gap drain in place. 5. Install the rigid fitting end of the sensing line to the elbow on the base of the relief valve and the swivel end to the fitting on the ball valve. MODEL NO. SERIES/SIZES DIMENSIONS WEIGT B C in. mm in. mm in. mm lbs. kgs. 909G- 4" 2" 009, 4" 009M2/M, 2" " 995 2 8 60 8 79 2.6.28 909G-C 4" " 009/909, 2" 009M2, 4" 2" 995 4 8 4 7 8 24 25.50.68 909G-F 4" " 009/909, 4" 2" 009M, 2" 009M2 4 8 6 4 7 2 5.25.47 909G-K 4" 6" 909, 8" 0" 909M 6 8 62 9 5 8 244 76 6.25 2.8 909G-M 8" 0" 909 7 8 87 4 286 4 02 5.50 7.0 99GC 4" & " 99 2 8 60 8 79 2.6.28 99GF 4" - 2" 99 4 8 8 7 6 24 76 4.26.9 957-G (Complete) 2 2" 0" 957 7 2 90 0 6 258 2 5.5.68 957-G (Splash Guard Only) 2 2" 0" 957 994GK-P 2 2" 0" 994 8 20 4 286 2 5.5.68 995-G " 6" 995 5 27 8 20 2 8 60 Vent Elbows Used with Watts ir Gaps for vertical installation of reduced pressure zone assemblies. 909EL- 4" 2" 009, 4" 009M2/M, 2" " 995 909EL-C 4 " 009/909, " 2" 009M2, 4" 2" 995 2 8 60 2 8 60.8.7 909EL-F 4" 2" 009M, 4" 2" 009/909, 2" 009M2 5 8 92 5 8 92 2.9 909EL- 2 2" " 009/909 2 5 994EL-F (vertical) 2 2" 0" 994 4 7 8 24 9 229 2 5 4.8 Epoxy coated For additional information, request literature ES-G/E:/TC. 57 C B C ir Gap Miscellaneous Backflow Products B

Spools and Flanges For Retrofitting Backflow Preventers Spools Watts has created Make up Spools for use when retrofitting a backflow preventer into the longer lay length of an existing assembly. Watts spools are available in lightweight 00 series stainless steel or epoxy coated carbon steel and come standard with WW 50# class D carbon steel flanges. 50# class D stainless steel flanges available upon special request. Spools 7 Miscellaneous Backflow Products Flanges Watts has created Make up Flanges for use in piping applications where there is a need for additional fitting lay length. Watts flanges are available in three styles: WW 50# modified class D Zinc plated carbon steel with standard bolt pattern WW 50# modified class D Zinc plated carbon steel flanges with standard pattern slotted WW 50# modified class D stainless steel flanges with standard bolt pattern SPOOLS MODEL NO. SIZE W-SPL 2 2 x 7 8 W-SPL 2 2 x 8 W-SPL 2 2 x 5 6 W-SPL 2 2 x 4 W-SPL 2 2 x 4 5 6 W-SPL x 7 8 W-SPL x 2 2 W-SPL x 2 W-SPL x 5 6 W-SPL x 4 W-SPL 4 x 5 8 W-SPL 4 x 5 7 8 W-SPL 4 x 6 8 W-SPL 4 x 6 6 W-SPL 4 x 7 8 W-SPL 4 x 7 5 6 W-SPL 4 x 8 W-SPL 4 x 9 7 8 W-SPL 4 x 0 4 W-SPL 4 x 0 7 8 W-SPL 4 x 7 8 W-SPL 4 x 2 W-SPL 4 x 4 7 8 W-SPL 6 x 5 8 W-SPL 6 x 8 8 W-SPL 6 x 9 6 W-SPL 6 x 0 4 W-SPL 6 x W-SPL 6 x 2 7 6 W-SPL 6 x 2 2 SPOOLS MODEL NO. SIZE W-SPL 6 x 8 W-SPL 6 x 7 8 W-SPL 6 x 4 W-SPL 6 x 4 8 W-SPL 6 x 4 7 8 W-SPL 6 x 6 7 8 W-SPL 6 x 7 8 W-SPL 8 x 2 8 W-SPL 8 x 6 8 W-SPL 8 x 6 2 W-SPL 8 x 7 8 W-SPL 8 x 8 8 W-SPL 8 x 2 6 W-SPL 8 x 2 8 W-SPL 8 x 22 8 W-SPL 8 x 22 7 8 W-SPL 8 x 2 8 W-SPL 8 x 25 5 8 W-SPL 0 x 6 8 W-SPL 0 x 6 4 W-SPL 0 x 28 8 W-SPL 0 x 28 8 W-SPL 0 x 28 2 W-SPL 0 x 29 7 8 W-SPL 0 x 29 5 6 W-SPL 0 x 2 8 W-SPL 0 x 2 7 6 W-SPL 0 x 4 8 W-SPL 0 x 7 4 FLNGES MODEL NO. SIZE W-FLG SS-U 2 x 4 W-FLG SS-U 2 x 2 W-FLG SS-S 2 x 4 W-FLG SS-S 2 x 2 W-FLG SS-U 2 2 x 4 W-FLG SS-U 2 2 x 2 W-FLG SS-S 2 2 x 4 W-FLG SS-S 2 2 x 2 W-FLG Z-U x 2 W-FLG Z-U x W-FLG Z-S x 2 W-FLG Z-S x W-FLG SS-U x 4 W-FLG SS-U x 2 W-FLG SS-S x 4 W-FLG SS-S x 2 W-FLG Z-U 4 x 2 W-FLG Z-U 4 x W-FLG Z-S 4 x 2 W-FLG Z-S 4 x W-FLG SS-U 4 x 4 W-FLG SS-U 4 x 2 W-FLG SS-S 4 x 4 W-FLG SS-S 4 x 2 W-FLG Z-U 6 x 2 W-FLG Z-U 6 x W-FLG Z-S 6 x 2 W-FLG Z-S 6 x W-FLG SS-U 6 x 4 W-FLG SS-U 6 x 2 W-FLG SS-S 6 x 4 W-FLG SS-S 6 x 2 W-FLG Z-U 8 x 2 W-FLG Z-U 8 x W-FLG Z-S 8 x 2 W-FLG Z-S 8 x W-FLG SS-U 8 x 4 W-FLG SS-U 8 x 2 W-FLG SS-S 8 x 4 W-FLG SS-S 8 x 2 W-FLG SS-U 0 x 4 W-FLG SS-U 0 x 2 W-FLG SS-S 0 x 4 W-FLG SS-S 0 x 2 Size = Valve size x Thickness Z = Zinc SS = 04 Stainless Steel S = Slotted U = Unslotted 58 For additional information, request literature F-Spools/Flanges.

Series PVS-000 Pre-engineered Valve Stations PVS-000 Series PVS-000 Pre-Engineered Valve Stations are custom configured water flow control systems that are assembled from proven, reliable Watts components to meet exacting project application requirements. Watts pre-engineered valve stations are factory pre-assembled, tested and optionally certified by independent agencies to ensure flow performance for critical building demands. 7 Features Maximum flow performance with low pressure drops Wide flow control ranges meet standard end emergency peak flow requirements Standard flow design to >0,000 gpm Integral backflow prevention devices, meter, pressure regulators, automatic control valves, strainers, headers, shutoff valves, and instrumentation as needed to suit specific applications UL/FM, SSE, IPMO, USC certified or listed components as required for service Single point of connection for fire protection, potable water and irrigation services (where approved by local codes) Standard vault, vertical, and horizontal mounting configurations Integral slip and alignment flanges correct for site variations and relieve pipe stress Benefits Watts pre-engineered valve stations provide the following benefits: Reduction of installation time from days to hours, minimizing installations costs Redundant flow paths provide uninterrupted water flow while device is being tested or maintained, reducing overtime labor costs Operates below OS mandated maximum noise levels Corrosion resistant design reduces component maintenance costs Optional pre-installation performance certification ensures conformance to design criteria at site Reduction in the number of overall components needed through Watts innovative design program One supplier of components, one source of responsibility, Watts, a leader in valve technology for over 0 years pplications Watts pre-engineered valve stations are custom fit to your specifications and are ideal for a wide variety of flow control applications including: ospitals Schools Multi-Family Dwellings Restaurants Industrial Facilities Other similar buildings Miscellaneous Backflow Products Field proven in over 00 installations and years of history Expansion capability Built-in protection for system upsets (i.e. seismic shocks) IMPORTNT: Inquire with governing authorities for local installation requirements For additional information, request literature PG-ValveStations. 59

Series BIC-000 Backflow Irrigation Control Stations BIC-000 7 Miscellaneous Backflow Products Series BIC-000 Backflow Irrigation Control Stations combine the master valve, regulator valve, backflow preventer, preload valve and high-pressure lockout switch all in one easily located component. Constructed using best practice design principles, these systems maximize operating performance and reduce pipe breaks and leakage within the irrigation system. Watts BIC-000 station minimizes system-operating pressure during both the system operation as well as when there is no flow to the system to reduce water line breaks, has a single warranty policy and is pre-tested to ensure reliable operation "out of the crate". Features Preload Pilot. The entire irrigation pressure piping system is maintained with a preload stand-by, field adjustable, low pressure control valve. This in combination with a higher set point on the regulator and master valve creates a buffer when turned on. igh-pressure Lockout Switch. When high pressure is detected, the switch will lock out the 24V circuit; making the system inoperable until the problem is addressed. This prevents high pressure shock and water hammer when the system is allowed to turn on. ll components are flanged type, nut and bolt modular design for easy replacement. 24-hour monitoring system of the outlet pressure for excessive buildup above set operating pressure. Water is conserved by reducing or eliminating potential line breaks caused by high pressure. The master valve/regulator is installed at the backflow assembly which provides a shutoff and pressure control of the entire system. System ttributes ll components are above ground level on a stainless steel station Combines the Master Valve, Regulator Valve, and Backflow ssembly in one easily located component 60 For additional information, request literature F-BIC-000.

Series FR 500 Thermostatic Freeze Relief Kits Sizes: /8", /4", /2 "and /4" (, 8, 5 and 20mm) 8" and 4" 2" and 4" Series FR 500 Thermostatic Freeze Relief Kits are designed to keep water from freezing in the backflow preventer, while avoiding discharges based on the air temperature dropping below freezing. Series FR 500 thermostatically measures the water temperature and opens at 5 F (.6 C) and closes at 40 F (4.4 C). 7 Features Compact Easy to Install Low Maintenance Controlled by Water Temperature vs. ir Temperature IPMO pproved Dimensions Materials Body: Bronze Springs: Stainless Steel Internals: DZR Brass Pressure Temperature Working Temperature: 5 F (.6 C) Maximum Pressure: 75psi (2. bar) pprovals IPMO Miscellaneous Backflow Products /6" (0mm) W/plug 2 5 /6" (59mm) Test Cock Optional 2 /4" (58mm) 5 /8" (6mm) /4" (82mm) Sizes: /2" and /4" (5 and 20mm) 2" (5mm) UELC Sizes: /8" and /4" ( and 8mm) For additional information, request literature ES-FR500. 6

Guide to Options ydrant Connections C The hydrant connection option is designed to prevent backflow of contaminants from tank and truck filling operations. fire hydrant should be considered an open conduit to the water supply system and as such should be protected from actual or potential cross-connections that can occur. While fire hydrants are normally considered to be safety devices for fire fighting purposes, the growing use of them to supply water for construction sites, roadwork, street cleaning equipment and hydroseeding, can lead to the possible contamination of the water supply. vailable on series: 2" (50mm) 007, 009, 909 8 Guide to Options Locking Ball Valve andles L The locking ball valve handles options is designed for use on fire protection systems to prevent accidental closure of the shutoff valve. Locking ball valve handles provide vandal resistance for outdoor installations and prevent the removal of the stem nut and ball valve handle. These locks allow an assembly's bypass valve to be locked in the open position to prevent isolation of the meter and resultant theft of water. vailable on 2" 2" (5-50mm) series: 007, 009, 909 Internal Polymer Coating PC The internal polymer coating option provides extended corrosion protection on sensitive sealing areas and machined surfaces. The coating ensures the smooth operation of the sliding and moving parts and common problems such as pitting, mineral build ups and galling are negligible even after lengthy periods in extremely corrosive water conditions. vailable on series: 007, 008, 009, 909 Elbow Fittings for 60 Rotation QT The QT elbow fittings for 60 rotation option allows the installer to pivot the valve's inlet and outlet in the direction of the piping since often times they do not align exactly. This option provides great flexibility to the installer and saves space, time, materials and money. vailable on series: 009, 99 62

Shutoff Valve Options Watts offers a variety of different shutoff valve options and combinations to meet most any installation requirements. Shutoff valve options include: grooved and flanged OSY & NRS gate valves, valves with 2" (50mm) operating nut and post indicator plate and grooved butterfly valves. vailable on series: 757, 757a, 774, 774X, 757DCD, 757aDCD, 774DCD, 774XDCD, 957, 994, 957RPD, 994RPD Inlet Options Outlet Options PIV GxF BFG Shutoff BFG Shutoff 8 OSY G&G OSY GxG Guide to Options OSY FxG NRS FxG NRS GxF OSY GxF For additional information, request literature S-SilverEagleshutoffs 6