Speed Controller 2-Quadrant PWM configurable via PC

Similar documents
Speed Controller 2-Quadrant PWM configurable via PC

3242 G 024 BX4 CS/CC 24 3,6 18,2 77,3 1,6 / 12,4 9 / ball bearings, preloaded 0,015. stainless steel 370 electronically reversible

2232 S 024 BX4 CSD/CCD 24 12,4 6,4 67,7 2 / 17 4,1 / ball bearings, preloaded 0,015. stainless steel 77 electronically reversible

Accessories Adapter for Motion Controller V2.5 and Speed Controller

4,5 / 27 2,0 / steel, black coated. clockwise, viewed from the front face. ø15,9 ø17-0,052 ø6-0,05. ø3,5 8,1 ±0,3 2, T

Silencer Series Brushless DC Motors

Names and Functions of Driver Parts

Pulse Encoder Interface Kit For Use With FlexPak 3000 and WebPak 3000 DC Drives M/N 907FK0101

LSM60 Series. Brushless Servo Motors. Product Description

Servo Motors & Drives. Gearmotors & Gearheads. Linear & Rotary Positioning Stages. Luge LM Product Manual

DRV-1. Step Motor Drive. User Manual Mentor Avenue Cincinnati, Ohio Tel (513)

2: A, B 3: A, B, Z 4: A, A _, B, B _ 6: A, A _, B, B _, Z, Z _

User s Manual. For DM542T. Full Digital Stepper Drive

Pluse Input Type Integrated Step Motor STM-R Series

Brushless DC Drives. Catalogue. February 2009

Operating manual for micro annular gear pump mzr-7240

MondoStep 7.8. High Performance Microstepping Driver. User s Manual. Version PROBOTIX All Rights Reserved

ILE1F661PB1A0 brushless dc motor V - CANopen DS301 interface - L = 122 mm - w/o gearbox

Operating Manual For Stepper Driver

ILE2K661PC1A1 brushless dc motor V- EtherNet/IP interface - L = 174 mm- 18:1

Manual of SM442. High Performance Microstepping Driver. Nietz Electric Co.,Ltd.

2.3. Adjustable Frequency Drives. Contents. Standards and Certifications

AC Servodrives Bivector 300/500 Advanced solutions for automation

User s Manual. For DM860T. Fully Digital Stepper Drive. Version 1.0 Designed by StepperOnline All Rights Reserved

MDC V, 30A Brushless Controller. User s Guide L East Orangefair Lane, Anaheim, CA

ILE1F661PC1A0 brushless dc motor V - CANopen DS301 interface - L = 122 mm - w/o gearbox

SERIES PR90H PROGRAMMABLE INCREMENTAL HOLLOW SHAFT ENCODER FOR INDUSTRIAL APPLICATIONS REFERENCE PR90H - C C - C. External diameter 58 mm

STR3. Step Motor Drive. User Manual

AxCent Servo Drive AB30A200

KL-8070D. Fully Digital Stepping Driver. Table of Contents 1. Introduction, Features and Applications...1 Introduction...1 Features...

Mini-MAG Positioning Products

Gearmotors & Gearheads. Servo Motors & Drives. Linear & Rotary Positioning Stages. Direct Drive Rotary Table Product Manual

ELECTRO-MOBILE Programming Kelly KEB SCANDINAVIA AB

SR3-mini. Step Motor Drive User Manual. AMP & MOONS Automation

ILE1B661PC1A1 brushless dc motor V - Profibus DP interface - L = 174 mm - 18:1

URM-00 TRAINING MODULE FOR INDUSTRIAL ELECTRIC MOTORS FOR MAIN DRIVE AND CONTROL CIRCUITS EDUCATIONAL KIT TO STUDY MOTORS CONTROL AND PROTECTION

DLA SERIES + ACCESSORIES

Motor/Drive Configuration

VARIODRIVE 3-phase external rotor motor. VARIODRIVE technical information VARIODRIVE

Optical Shaft Encoder Page 1 of 6. Description. Features

IRT 4000 AT-S/M/L. Technical Manual. quality IN MOTION. quality IN MOTION

Catalog EC02EN. Brushless DC. Motors. Drives. EA-Series SC-Series. RapidPower Series E-Series EXC-Series.

User's Manual. For M542T. High Performance Microstepping Driver. Version All Rights Reserved

BAC2000ind.

ILE2T661PB1A3 brushless dc motor V - Modbus TCP interface - L = 174 mm - 54:1

Brushless. Motors. Drives. RapidPower Series E-Series EXC-Series. EA-Series SC-Series ACS-Series ACE-Series PFC-Series.

CENTROIDTM. AC Brushless Drive. Product Spec Sheet

SR8-Plus 2 Phase Step Motor Drive

10 amp hall sensor motor drivers

PRODUCT USER MANUAL. SQ57 CANopen Motors. SMI21 CANopen. Important Notes

User Manual of 2MA2282

MCD Evaluation Board for Pump Motor Control Reference Guide

User s Manual. For M542. High Performance Microstepping Driver. Version All Rights Reserved

BG45 BG65S BG75 Axial Parallel Axial Parallel Axial Parallel CASM-32 (LS/BS/BN) X X CASM-40 (LS/BS/BN) X X X X CASM-63 (LS/BN/BF) X X

715B CONTROL SERIES. Instruction Manual Line Voltage DC Brushless Motor Control CONTROLS. Phone (317) Fax (317)

Power in new dimensions

Note: All windings shown are standard configuration. Please contact Motion Technologies for availability of all others

MDC Series

PKS-FD Servo System

5 amp 48 volt sensorless motor drivers

BLY34MDA Series. 50V, 30A Brushless Controller / Motor. User s Guide E Landon Drive, Anaheim, CA

BMS Series. DC Brushless Torque Motors. Slotless, brushless stator design provides zerocogging torque for unsurpassed velocity control

Brushless DC Motor Systems

Weatherproof Tubular Slip Ring Assembly

BLDPN30001 Series. 30A Brushless DC Controller. User s Guide E. Landon Drive Anaheim, CA

Sensorless Brushless DC-Servomotors

User s Manual-M752. Stepper Motor Driver. Version All Rights Reserved. Attention: Please read this manual carefully before using the driver!

Variable speed controllers for asynchronous motors

User's Manual O

BR Second Position Voltages. AA Fourth Position

PT1054 Lithium Ion Battery Linear Charger

ACME SCREW LINEAR ACTUATOR. OVERALL DIMENSIONS La =Lc + Stroke Lc T Capacitor

ILA2D572TC1F0 integrated drive ILA with servo motor V - DeviceNet - indus connector

PIglide RM Rotation Stage with Air Bearings

USD ,4A 42Vdc Bipolar Driver

10 amp hall sensor motor drivers

Unidrive M600 High performance drive for induction and sensorless permanent magnet motors

MDCKB VAC, 8A Brushless Controller. User s Guide E. Landon Drive Anaheim, CA

ATOTH-G Series BLDC Motor Controller. User s Manual

ABB Sace S.p.A. presents its new BSD servo system, a compact, high-performance and easy product.

10 amp hall sensor motor drivers

Servomotors. AC brushless servomotors TGT a TGH

MDCKB VAC, 8A Brushless Controller. User s Guide E. Landon Drive Anaheim, CA

Twin Line. Motion control

ILA1F572PB1F0 integrated drive ILA with servo motor V - CANopen - PCB connector

Kelly HSR Series Motor Controller with Regen User s Manual V 3.3. Kelly HSR Opto-Isolated Series Motor Controller with Regen.

SIMOREG DC Master. Application Tips on Configuration, Hardware, Software, and Closed-Loop Control. 6RA70 Series

ADJUSTABLE FREQUENCY CONTROLS SENSORLESS VECTOR CONTROL. Dual Rating. Technologies Inc. mgitech.com NRTL/C CERTIFIED

BLH. 24 VDC Input 15W / 30W / 50W / 100W BLH

1291BL Series Technical Specification Single Axis Position and Rate Table System

MDC VAC, 15A Brushless Controller. User s Guide. 910 East Orangefair Lane, Anaheim, CA

SCOTT DRIVE 100. Features. Features

Brushless DC Motor Systems FBL2 Series

ZETA advanced microstep drive. Microstepping systems - the next generation... Automation. Quicker settling following a speed change

KNC-PKS-FD S-AAK-DKH

Unidrive M700 Class leading performance with onboard real-time Ethernet

MDC Series

MSD Phase Step Motor Drive User Manual

MDCSL V, 30A

Technical Explanation for Inverters

Transcription:

2-Quadrant PWM configurable via PC For combination with: DC-Micromotors and Brushless DC-Servomotors Series SC 1801 Power supply for electronic Power supply for motor Max. continuous output current Max. peak output current Total standby current Input/output (partially free configurable) UP Umot Idauer Imax Iel max SC 1801 P SC 1801 F SC 1801 S 4,0... 18 4,0... 18 4,0... 18 1,8... 18 1,8... 18 1,8... 18 1 1 1 2 2 2 0,018 0,018 0,018 3 3 3 V DC V DC A A A Tightening torque, terminal strip Weight - 0,12... 0,15 0,12... 0,15 4 10 12 Nm g PWM switching frequency 2) Efficiency fpwm η 96 95 khz % Speed range: BL motors with Hall sensors (digital) BL motors with Hall sensors (analog) DC motors with encoder Scanning rate Resolution of encoder with DC motors Operating temperature range Storage temperature 500... 100 000 50... 60 000 100... 30 000 500 65 535 25... + 60 25... + 85 rpm rpm rpm µs inc./rev. C C at 22 C ambient temperature 2) for brushless DC-Motors without Hall sensors: fpwm 24 khz Versions Version Option 4) Motor Sensor Type Set speed value Speed at Part No. Conformity Type specification Unsoll =10 V SC 1801 S 3530 BL Hall sensors (digital) 3) 0... 10 V 30 000 rpm 6500.01377 CE SC 1801 S 3531 DC Incremental encoder 2) 0... 10 V 10 000 rpm 6500.01393 CE SC 1801 F 3533 BL sensorless (high speed) 0... 10 V 40 000 rpm 6500.01378 CE SC 1801 P 3530 BL Hall sensors (digital) 3) 0... 10 V 30 000 rpm 6500.01379 SC 1801 P 3531 DC Incremental encoder 2) 0... 10 V 10 000 rpm 6500.01394 SC 1801 S 4763 BL Absolute encoder 2 pole 0... 10 V 30 000 rpm 6500.01592 SC 1801 P 4763 BL Absolute encoder 2 pole 0... 10 V 30 000 rpm 6500.01593 SC 1801 F 4763 BL Absolute encoder 2 pole 0... 10 V 30 000 rpm 6500.01594 SC 1801 S 4289 BL Hall sensors (analog) 2 pole 0... 10 V 40 000 rpm 6500.01475 SC 1801 P 4289 BL Hall sensors (analog) 2 pole 0... 10 V 40 000 rpm 6500.01476 SC 1801 F 4289 BL Hall sensors (analog) 2 pole 0... 10 V 40 000 rpm 6500.01477 SC 1801 S 3980 BL Absolute encoder 4 pole 0... 10 V 30 000 rpm 6500.01435 SC 1801 P 3980 BL Absolute encoder 4 pole 0... 10 V 30 000 rpm 6500.01440 SC 1801 F 3980 BL Absolute encoder 4 pole 0... 10 V 50 000 rpm 6500.01441 SC 1801 S 4764 BL Hall sensors (analog) 4 pole 0... 10 V 10 000 rpm 6500.01595 SC 1801 P 4764 BL Hall sensors (analog) 4 pole 0... 10 V 10 000 rpm 6500.01596 SC 1801 F 4764 BL Hall sensors (analog) 4 pole 0... 10 V 10 000 rpm 6500.01597 The velocity range can be configured by software. Versions with PWM and other configurations are available on request. 2) Preset value is 512 lines 3) Factory pre-configured for 2 pole motors. For operation with 4 pole motors the speed controller must be reconfigured with the software Faulhaber Motion Manager. 4) For changes to the factory setting the use of a programming adapter is required (see accessories). Accessories Motor for SC 1801 S Type Part No. Programming adapter Starterkit 6501.00088 Programming adapter 6501.00097 Motor connector adapter 0620... B BL 6501.00083 penny-motor BL 6501.00090 BX4 BL 6501.00085 Encoder adapter IE2 DC 6501.00084 HEDS DC 6501.00001 Page 1/6

Dimensional drawing and connection information SC 1801 S 17,78 (7x2,54) 6 34 (2x) ø2,2 1 16 15,25 (6x2,54) SC 1801 S 13,2 25 RM 2,54 <14 8 9 1 UP Connection No. Function 2 Umot 3 4 Unsoll 5 DIR 6 FG 9 10 11 12 S 13 VCC 14 15 16 Dimensional drawing and connection information SC 1801 P 32 ±0,4 22,86 <14 Connection No. Function 6 1 SC 1801 P 9 16 23 ±0,4 RM 2,54 0,635 6,6 ±0,5 1 UP 2 Umot 3 4 Unsoll 5 DIR 6 FG 9 10 11 12 S 13 VCC 14 15 16 Dimensional drawing and connection information SC 1801 F 17,78 (7x2,54) 6 1 34 (2x) ø2,2 15,25 (6x2,54) SC 1801 F 13,2 9 11 9 16 25 RM 2,54 Connector Information LIF-Connector 3-pole and 8-pole <14 8 Connection No. Function 1 UP 2 Umot 3 4 Unsoll 5 DIR 6 FG 9 10 11 12 S 13 VCC 14 15 16 Page 2/6

SC Function Description of connections (Motor-dependent) DC-Motors with s with s with s with s with Encoder Hall sensors Absolute encoder digital Hall sensors digital Hall sensors + encoder + brake/enable Connection,, : Motor connection Mot + Mot - reserved Connection,, : Sensor input reserved Hall sensor A DATA Hall sensor A Hall sensor A encoder canal A Hall sensor B reserved Hall sensor B Hall sensor B encoder canal B Hall sensor C CLK Hall sensor C Hall sensor C f 400 khz Connection IO1, IO2 - logic input IO1 reserved reserved reserved encoder B brake IO2 reserved reserved reserved encoder A enable Connection information (general) Connection UP : UP power supply electronic Connection Umot : Umot power supply motor coil Connection : ground Connection Unsoll : Uin = 0... 10 V / > 10 V... max. UP (standard version) analog input set speed value Uin < 0,15 V motor stops Uin > 0,3 V (0,5 V) 2) motor starts digital input PWM for set speed value 500... 18 000 Hz duty cycle d = 0% motor stopped d = 50% half of maximum speed d = 100% maximum speed input resistance Rin 5 kω signal level PLC 7,5... Up high 0... 2 low signal level TTL 3) 2,8... Up high 0... 0,5 low Connection DIR : digital input direction of rotation to ground or level < 0,5 V counterclockwise level > 3,0 V clockwise input resistance Rin 10 kω Connection FG : max. UP / 15 ma open collector with pull-up resistor 4) fault output switched through to no error frequency output (BL motor only) 1, 3, 6, 8, 16 5) lines per revolution Connection IO1, IO2 : n.c. reserved digital input 6) signal level TTL 2,8... Up high 0... 0,5 low (IO2) high motor enabled low motor disabled (IO high motor stopped low motor run Connection VCC : output voltage 5 V DC for external use max. output current for SC 1801 S, F, P» ICC = 25 ma SC 2402 P» ICC = 20 ma S» ICC = 30 ma P» ICC = 100 ma S» ICC = 100 ma Connection S : signal ground > 10 V for set speed value not defined. 2) Data in parentheses apply to BL motors operating without sensors. 3) Not available for / 4) 22 kω (SC 1801, SC 2402, ) 47 kω (, ) An additional external pull-up resistor can be added to improve the rise time. Caution: Iout max. 15 ma must not be exceeded. 5) Values apply to 2-pole motors. The given values double for 4-pole motors. 6) With appropriate hardware. Page 3/6

Circuit diagram - brushless with Hall sensors (Option 3530) Digital output Electronic supply Motor supply FG 22k UP Umot n soll Protection function: Overtemperature PI-velocity controller U a 3 Phase PWM block commutator MOSFET Power amplifier BL Motor Setpoint input 0... 10 V Rotational direction input Unsoll DIR Evaluation rotational direction Microcontroller Speed calculation ϕ(t) Armature position calculation I 2 t-current limitation I ist Hallsensor A Hallsensor B Hallsensor C Vcc 5V-Control +5V R S S Connection diagramm supply unit Configuration Full Drive Controlled operation Programming adapter (optional) z.b. 5...18 V z.b. 0...10 V S 12 V 12 V Rev controller via parameter Umot Rev set-point specification via parameter Unsoll Connection diagram operation mode DC-Micromotor with encoder S Motor Motor + +5V (Versorgung) (supply) Kanal B Kanal A DC-Motor with encoder Page 4/6

Connection diagram operation mode BL motor with Hall Sensors S +5V (Versorgung) (supply) Hall C Hall B with Hall sensors Hall A Connection diagram operation mode BL motor with digital Hall Sensors and Encoder Kanal Channel B B Kanal Channel A A FG DIR SC 2402 S +5V (supply) (Versorgung) Hall C with digital Hall sensors and encoder IE2 Channel Kanal B Channel Kanal A Hall B Hall A Connection diagram operation mode BL motor with digital Hall Sensors and Brake / Enable 0...10 V Brake Enable FG SC 2402 DIR S +5V (Versorgung) (supply) Hall C Hall B with digital Hall sensors 12 V Hall A Page 5/6

Connection diagram operation mode BL motor with AES S +5V (supply) (Versorgung) CLK Hall C CS Hall B with absolute encoder DATA Hall A Connection diagram operation mode DC and BL motor sensorless FG DIR SC 1801 SC 2402 S Motor Motor + DC-Motor sensorless sensorless Page 6/6