FIRE PUMP SYSTEMS. FIRE PUMP SINGAPORE PTE LTD No.8 Keng Chin Road #13-11 Cyan South Tower Singapore

Similar documents
PRODUCING TRUST IN FIRE AND SAFETY FIRE PUMP SYSTEMS A PRODUCT OF COMPLIANT.

PRODUCT OF FIRE PUMPS SYSTEMS

900 Series Split Case Fire Pump Systems

Series 4600F. HSC Fire Pumps & Packaged Systems

FIRE PUMPS & PACKAGED

FIRE PUMPS F AI LISTED R LISTED N K S MOR S E P U IT Y S Y S T E M CE R T IF IE D

Peerless Pump FIRE PUMPS. Horizontal Split-Case, Vertical Turbine, In-Line and End Suction. Sterling Fluid Systems (USA), Inc.

MOBILE FIRE - RESCUE DEPARTMENT FIRE CODE ADMINISTRATION

NMSU FIRE DEPARTMENT FIRE PUMP ACCEPTANCE TEST

Fire Pump Systems. For the protection of life and property, A-C Fire Pump offers package systems that meet every fire protection need.

Waterfall Pumps Manufacturing

AURORA COMPACT FIRE PUMP SYSTEMS

University of Houston Master Construction Specifications Insert Project Name

NC State University Design and Construction Guidelines Division 23 Hydronic Pumps

SECTION DOMESTIC-WATER PACKAGED BOOSTER PUMPS

SECTION DOMESTIC-WATER PACKAGED BOOSTER PUMPS

Bristol: A History & Future.

Centrifugal End Suction Fire Pumps

Reliable Packaged Solutions in Plumbing

TECHNICAL BROCHURE B36/3742 R2 3642/3742 CLOSE-COUPLED AND FRAME-MOUNTED CENTRIFUGAL PUMPS

3312 Model. pumping Model Model AURORA Series HORIZONTAL AND VERTICAL CLOSE-COUPLED PUMPS

SECTION (15444) - DOMESTIC WATER PACKAGED BOOSTER PUMPS

FAIRBANKS FIRE PUMPS JOCKEY PUMP SELECTIONS MODELS 933 & 934

A-C Fire Pump. Fitting and Accessories A-C 100A

F F F F F F. Foam Systems Deluge Systems Hydrant Systems Sprinkler Systems Hose Reel Systems Hose Rack Systems

TECHNICAL BROCHURE B36/ /3742 CLOSE-COUPLED AND FRAME-MOUNTED CENTRIFUGAL PUMPS

G&L Pumps. TECHNICAL Brochure BAC8100. Series A-C 8100 SPLIT CASE PUMPS

4500C Series Vortex Pumps

SUGGESTED SPECIFICATIONS

Contact. Total Maintenance Solutions for Optimal Performance. At the Forefront of Serving the Oil & Gas industry

SM / SMI N N O V A T I O N E F F I C I E N C Y Q U A L I T Y

VSC /VSCS Pumps Technical Brochure

SECTION PUMPS GENERAL PUMPS PART RELATED DOCUMENTS

TYPE PC Propeller Condensate Pumps

N N O V A T I O N E F F I C I E N C Y Q U A L I T Y JTN. Heavy Duty, Multi-Stage, API 610 Process Pump

Multi-Institutional Academic Health Science & Research Center Evansville, IN

Model 133 Models 134 & 135 AURORA 130 SERIES SINGLE STAGE TURBINE TYPE PUMPS

320 Series Vertical Sump Pumps

XFLO XS SERIES. Single Stage Double Suction Split Casing Centrifugal Pump

.2 Section Waste Management and Disposal..5 Section Thermometers and Pressure Gauges Piping Systems.

340 Series Double Suction Split Case Pumps

Bulletin BX-512H. Bell & Gossett. Series HSC-S Pumps Technical Bulletin. Bell & Gossett. Part of the. Equipment Selection Programs

SINCE Double Suction Split Case Fire Pump. Series 4800 & (New Generation) 001-cat f

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017

KS Valves & Pumps.

OUR MISSION IS FOR YOU TO ACHIEVE YOUR GOALS BY PROVIDING INNOVATIVE & QUALITY PRODUCTS.

Instructions for Installation, Operation, Care and Maintenance

PATTERSON PUMP COMPANY

SCE Heavy Duty, Single Stage, Overhung, API 610 Process Pump (OH2)

Basic Hydraulic Features. Basic Mechanical Features

1. Wiring Diagrams: Power, signal, and control wiring.

PROJ. NO SECTION HYDRONIC PUMPS

Bulletin BX-420C Bell & Gossett. VSC /VSCS Pumps Technical Bulletin. Bell & Gossett. Part of the. Equipment Selection Program

Hydropak Booster Systems. Series motralec

Goulds Small Capacity Double Suction Pump

Installation Vertical Pump: Installation 'CM' and 'CDM' Style: Operation:

Sleeve Valves Energy Dissipaters

TC & FC SERIES CENTRIFUGAL PUMPS

Darley UHP-HV Diesel Specification 1

multiflow Multistage Heavy Duty Axially

Series 1510 Centrifugal Pumps

25198:- 1/31/12 11:24 AM Page 2 Filtration Systems

LEAD FREE * PVS-7000 Engineered Flood Protection Valve Station with SentryPlus Alert

1000 Series Neptune Booster Systems. Flows to: 20,000+ GPM Heads to: 700+ PSI Temperatures to: 250 F

AquaBoost Packaged Systems

Municipal Water Treatment, Supply and Distribution

N N O V A T I O N E F F I C I E N C Y Q U A L I T Y JTN. Heavy Duty, Multi-Stage, API 610 Process Pump

Contents. Identification

Flood Control Integrated System (FCIS)

KIRLOSKAR ROMAK PUMP - RMK ISO 2858 / DIN EN / ISO KIRLOSKAR BROTHERS LIMITED A Kirloskar Group Company Established 1888

Application & Reference Data Typical Specifications. Section 914 Vertical Turbine Fire Pump

H 2. O Series CENTRIFUGAL End-suction Pumps. Versatile, really robust and definitely reliable

Stainless Steel The Next Generation of Backflow

INSTRUMENTS & SYSTEMS

Series FILE NO: DATE: Feb. 15, 1999 SUPERSEDES: DATE: Dec. 15, Hydropak Booster Systems

PWA-LF LOW FLOW ANSI PROCESS PUMP

POWERFORCE PUMP POWERFORCE PUMP POWERFORCE PUMP GLOBAL SOLUTIONS DESIGNING, MANUFACTURING AND PACKAGING FOR THE OIL & GAS INDUSTRY

SJP Vertical Propeller Pumps

EFQT/EFQU. EBARA Self Priming Trash Pump. Contents Project: Model: Chk d: Date:

PWA-LF LOW FLOW ANSI PROCESS PUMP

PIPELINE INJECTION PRODUCTS

TECHNICAL BROCHURE B45-70HB R2 45HB, 70HB HIGH PRESSURE CENTRIFUGAL BOOSTER PUMP

Elite. KSB Australia Pty Ltd. Centrifugal Pump

CLOSED COUPLED CENTRIFUGAL PUMPS

N N O V A T I O N E F F I C I E N C Y Q U A L I T Y

PWD. PWD API 610 BB1 Single Stage Pump

Pump Division MSP. Vertical, In-line, Medium Speed Pump. Bulletin PS-10-1c (E/A4)

Design Envelope Booster Systems. Design Envelope Booster Systems. FILE NO: DATE: Feb. 05, 2010 SUPERSEDES: DATE: Jan.

PWM APi 610 BB3 Multistage Pump

M50 L50 Series Multistage Regenerative Turbine Pumps

CLOSED COUPLED CENTRIFUGAL PUMPS

SECTION METERS AND GAGES FOR HVAC PIPING

Pump Acceptance Test Data

Photo: Swedish Coast Guard. Impeller Pumps

One & Two Stage Turbine Type Pumps

Laboratory Evaluation Report for: Backflow Preventer for Beverage Dispensing Equipment

Solids-Handling Pumps

ES-ISO ES-NEW GENERATION BACK PULL-OUT END SUCTION PUMPS

General Catalog. A New Vision for Quality Pumps. General Catalog

SUGGESTED SPECIFICATIONS Pump Frames NS3 thru OMC5

Transcription:

FIRE PUMP SYSTEMS FIRE PUMP SINGAPORE PTE LTD No.8 Keng Chin Road #13-11 Cyan South Tower Singapore 258710 Phone +65 6515 5123 Fax +65 6515 5272 Saha +65 90998565

Shandong Facility ABOUT FIRE PUMP SINGAPORE (FPS) FPS, with it s 20 years of experience has always been a progressive organization that has remained in the forefront of the Fire Fighting Industry with innovative, unconventional, environmental friendly, re-engineered and unique products. FPS in its state-of-the-art manufacturing plants in China works in close connections with renowned governmental and certification bodies to provide key answers to the challenges faced by the society. FPS brings together over 2-Decades of expertise and experience in form of Design, Consultancy, Manufacturing, Supply, Installation, Testing, Commissioning, Maintenance & Refurbishment of fire protection and fire fighting systems. 01

FPS CERTIFIED FACILITY FOR FIRE PUMP SYSTEMS TESTING FACILITY AND ASSEMBLY LINE FPS has established a fully equipped AS2941 Pump Testing facility with advance testing and calibration devices that enable to accurately inspect and test the operation of each Centrifugal Stationery Fire Pump to the required level of compliance standard as per AS2941. The Fire Pumps then undergo various processes in our modern well organized manufacturing and assembly line. Before delivering to our customers, each pump undergoes necessary inspection, tests and production control, during the Assembly process, for which all records are maintained. PERFORMANCE TESTS Performance curves are plotted within the FPS AS2941 Approved Pump Testing Facility showing the Efficiency, Break-Horsepower(kw), and Total Head developed at shutoff, at rated capacity, at 150%of rated capacity, and at selected intermediate capacities between shutoff and maximum capacities exceeding 150% of rated capacity. 02

FPS CERTIFIED FACILITY FOR FIRE PUMP SYSTEMS HYDROSTATIC TEST Each pump is to be tested hydro-statically for not less than 5 minutes. The test pressure is to be up to 2 times the maximum working pressure of the pump, but in no case less than 250psi (1724 kpa) to ensure no rupture or leakage through the castings at the test pressure. IMPELLER BALANCING The impellers of each pump shall be dynamically balanced to the G6.3 balance quality grade in accordance with the requirements for pump impellers in the Standard for Mechanical Vibration -Balance Quality. 03

CENTRIFUGAL FIRE PUMPS END SUCTION Top Centerline Discharge; Foot Supported Casing; Back Pullout Design; Self-venting Design; Efficiently Designed Shaft; Frame-mounted Design; Small Footprint Ideal For Retrofit; Dynamically Balanced Impeller; Heavy Duty With Heavy Wall Thickness; Hydrostatic & Certified Performance Tests; Back Pump Out Vanes. CAPACITY : 50GPM to 1500 GPM PRESSURES : 68 to 210 PSI (4.69 to 14.48 bar) MAX. WORKING : 225 to 250 PSI PRESSURES SPEED : RPM AS2941 AS2941 CERTIFIED & APPROVED PUMPS Compliance to AS2941 Design Requirements Match FM Approval standards Wide Range of Flows and Pressures Available in Electric Motor and Diesel Engine Driven Configuration Suitable for Commercial, Industrials and Buildings 04

CENTRIFUGAL FIRE PUMPS END SUCTION Notes: 1. All pumps are Hydro-statically Tested to minimum of 150% of it s Maximum Working Pressure and can withstand Double the Max. Working Pressure as per AS2941. 2. All pumps have Clock-Wise Rotation when viewed from the Driver Side. 3. All pumps are Single Stage Pumps. Model ST50-16 ST50-20 ST65-16 ST65-20 ST65-32 Flow (LPM) 720-900 1350-1650 1800 Approx Speed (RPM) Suction Flange Ø(mm) 65 80 Size Discharge Flange Ø(mm) 50 65 Max. Working Pressure (Bar) 16 16 Power Range (HP) 5-10 15-30 5-15 30-50 100 4. As per AS2941 The rated speed marked on the pump can vary within +/- 4% of the rated speed hence 3000 RPM pump can be driven with RPM Drivers. ST80-20 ST80-32 ST80-40 ST100-20 ST100-26 2400-3000 3420 3600 4500 100 125 80 100 16 21 16 40-80 80-130 200 60 120 ST125-26 5700 150 125 21 250 STM100/3 2700-5700 125 250 100 200 32 125-420 05

MOTOR DRIVEN SKIDS 06 Starlone Motor Driven Centrifugal Fire Pump Skids are available in combinations of both Listed & Approved End Suction Pumps and Horizontal Split Case Pumps coupled with Listed Fire Pumps Motors FPS/Starlone is an established well reputed manufacturer of Premium Custom Motor Driven Centrifugal Fire Pump Skids. We specialized in designing and developing packages in compliance to AS2941 requirements with Listed & Approved Drivers. FPS/Starlone offers Centrifugal Fire Pump Skids that meet every fire protection need. FPS/Starlone as standard uses AH High Efficiency Fire Pump Motors with our own Listed & Approved Centrifugal Fire Pumps to package Heavy Duty and High Quality Compact Skids. Our Listed & Approved Fire Pumps can also be coupled with any other Listed Fire Pump Motors of any specific brand as per client requirement. Driven by Listed & Approved Fire Pumps & Electric Motors. Well aligned and Coupled for Direct Operation. Skid Packages are Pre-Tested and Inspected thoroughly before release to client. One piece base plate with Anchor Bolt holes. Engineered coated hot rolled mild steel to resist corrosion and abrasion. Heavy Fabricated Steel Base Plate rigidly constructed to provide proper alignment of Pump & Motor. Compact skid Design with Small Foot-Print for Retrofit. High standard of Quality in material Construction finish and Workmanship.

DIESEL DRIVEN SKIDS 07 Starlone Motor Driven Centrifugal Fire Pump Skids are available in combinations of both Listed & Approved End Suction Pumps and Horizontal Split Case Pumps coupled with Listed Diesel Engine Drivers FPS/Starlone is an established well reputed manufacturer of Premium Custom Engine Driven Centrifugal Fire Pump Skids. We specialized in designing and developing packages in compliance to AS2941 requirements with Listed & Approved Drivers. FPS/Starlone offers Centrifugal Fire Pump Skids that meet every fire protection need. FPS/Starlone as standard uses Stallion or Clarke Diesel Engines with our own Listed & Approved Centrifugal Fire Pumps to package Heavy Duty and High Quality Compact Skids. Our Listed & Approved Fire Pumps can also be coupled with any other Listed Diesel Engine of any specific brand as per client requirement. Driven by Listed & Approved Fire Pumps & Diesel Engines. Well aligned and Coupled for Direct Operation. Skid Packages are Pre-Tested and Inspected thoroughly before release to client. One piece base plate with Anchor Bolt holes. Engineered coated hot rolled mild steel to resist corrosion and abrasion. Heavy Fabricated C-channel Structure constructed to provide proper alignment of Pump & Motor. Compact skid Design with Small Foot-Print for Retrofit. High standard of Quality in material Construction finish and Workmanship.

STARLONE JOCKEY PUMPS Starlone Jockey pumps are small, motor driven pumps used in conjunction with main fire pumps to compensate for minor leaks in the fire protection system and automatically maintain stand-by pressure. This reduces wear on the main pump and controller caused by unnecessary, frequent operation. Starlone Jockey Pump controllers are available for across the-line starting. Occasionally in a Fire Pump system, water leakage will occur at flanged or threaded pip connections, valve stems, stuffing boxes, etc. This normal loss of water will lower the system pressure gradually until the main Fire Pump is required to start. To minimize wear on the Fire Pump resulting from unnecessary operation, a Jockey Pump is recommended for the system. In a Jockey Pump system a small pump, motor. and controller/pressure switch unit is installed in the piping system. When the water pressure drops below the pre-set level, the pressure switch energizes a starter which activates the Jockey Pump. Correct water pressure is therefore maintained at all times. An optional minimum run timer will prevent the Jockey Pump frombeing started too frequently. This timer will ensure operation for a minimum of 3 minutes. If a fire should start, the pressure will continue to drop and the main Fire Pump will start. Automatic controllers also include a Hand-Off Automatic Selector switch for manual operation. 08

FIRE PUMP CONTROLLERS ELECTRIC PUMP CONTROL DIESEL PUMP CONTROL JOCKEY PUMP CONTROL AND ALARM PANEL All Fire Pump Controllers are factory-assembled, wired, tested as a unit and confirmed to all requirements of the latest edition of CP-52. Electric Fire Pump Controllers in general are classified by starting method, as full voltage or reduced voltage starting. The distinguishing factor in these starting methods is the amount of current (amperage) that is drawn by the motor during it s initial starting process (inrush). Fire controllers are generally provided in single unit but we provide indidual controller to all individual units. CP-52 LISTED 09

ACCESSORIES AND ARRANGEMENTS LEGEND ECCENTRIC REDUCER CONCENTRIC REDUCER GATE VALVE OS&Y CHECK VALVE FLEXIBLE JOINT ELBOW TEE COMPOUND PRESSURE GAUGE DISCHARGE PRESSURE GAUGE CASING RELIEF VALVE FLOW METER DRIP BALL VALVE BUTTERFLY VALVE GATE VALVE OS&Y CAN BE USED OPTIONAL GATE VALVE WASTE CONE MAIN RELIEF VALVE HOSE VALVE ELECTRIC CONNECTION RAW WATER COOLANT LINE PIPES SENSING LINE 10